Loading...
HomeMy WebLinkAboutLIVING OAKS - PDP - PDP170009 - SUBMITTAL DOCUMENTS - ROUND 2 - VARIANCE REQUEST1218 W. ASH, STE. A, WINDSOR, COLORADO 80550 TEL. 970.674.3300 – FAX 970.674.3303 March 22, 2017 Ms. Sheri Langenberger City of Fort Collins PO Box 580 281 North College Avenue Fort Collins, Colorado 80522-0580 Re: Living Oaks (221 East Oak Street) Request for Variance – Mathews Street Driveway Width Dear Sheri: The Living Oaks PDP at 221 East Oak is a proposed four-plex project that is classified as a multi-family development. Today, the site is vacant, but has two drive cuts, one on Oak Street and one on Mathews Street. The new four-plex will face Oak Street. An 18’ driveway on Mathews is proposed to serve the back of the property. New diagonal parking will be available in the Oak Street right of way with the removal of the existing drive cuts. The access point has been designed to be an 18’ wide Type I LCUASS driveway with 3’ wings. The standard width for multi-family projects with 3 units or more is 24’ (LCUASS 9.3.2.C). A variance is requested from the LCUASS Chapter 9.3.2.C to allow the 18’ wide driveway. Justifications for this variance are as follow: • The first floor area of each unit will be designated as a single car garage on the site plan. • Two-way traffic is available on this drive, even with the proposed width. Please see the attached images showing a passenger car getting into and out of the west most unit. Please note that this template is approximately the size of a Chevy Tahoe (so either a large car, or a mid to large SUV). • This driveway is not required for fire access. • LCUASS Standards allow public alleys to be as narrow as 12’. The alley west of this site is generally 18’ wide and functions. • Mathews is a local street with low speeds and the diag. The narrower driveway width not detrimental to the traffic on the street. • The site is only 50’ wide. A different LCUASS Standard states that commercial drives should not be more than 40% of the site frontage. This is not a commercial drive, but illustrates a LCUASS concept. A 24’ drive would literally take half of the frontage and then not meet this other standard. 1218 W. ASH, STE. A, WINDSOR, COLORADO 80550 TEL. 970.674.3300 – FAX 970.674.3303 CAR ENTERING WEST UNIT CAR EXITING WEST UNIT We do not anticipate that this variance will be detrimental to the public health, safety, or welfare. Please call me if you have any questions or require any additional information for the approval of this variance. Sincerely, Michael Oberlander, PE, LEED-AP Colorado Registration No. 34288