Cara Scohy
CS Design
2519 S. Shields St #129
Fort Collins, CO 80524
RE: 2106 South Taft Hill Road Single Family, PDP170002, Round Number 1
Please see the following summary of comments from City staff and outside reviewing
agencies for your submittal of the above referenced project. If you have questions about
any comments, you may contact the individual commenter or direct your questions through
the Project Planner, Meaghan Overton, at 970-416-2283 or moverton@fcgov.com.
Comment Summary:
Department: Engineering Development Review
Contact: Marc Ragasa, 970.221.6603, mragasa@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 02/14/2017
02/14/2017: Road profiles and cross sections are only needed for public
roads. Private drives aren't necessary, but you're more than welcome to leave it
in the plan set.
The profile and typical cross-sections were left in the plan set to aid construction. It is understood that this
will not be reviewed by the City.
Comment Number: 2 Comment Originated: 02/14/2017
02/14/2017: The driveway proposed does not meet current standards. The
driveway will need to be rebuilt as a Type III driveway at a minimum of 24'.
However, it is highly recommended to install a 36' wide driveway to
accommodate both a left and right turn movement out of the site. Please refer to
redlines on Sheet C3.00 for driveway configuration for both a detached and
attached sidewalk.
The drive entrance has been revised to maintain a 24’ width for a length of 39 feet which will accommodate for
a stacking of two cars.
Comment Number: 3 Comment Originated: 02/14/2017
02/14/2017: Please show the limits of removal on Taft hill road as well as
Page 2 of 14
Dover Drive that's needed for utility cuts/sidewalk chase installation.
The approximate limits of street cut has been shown on the plans for Taft Hill Road to account for the
construction of the drive entrance and the water line installation. The approximate limits of concrete removal
have been shown on Dover Drive to account for the construction of the roll over curb and gutter, sidewalk,
and sidewalk chase.
Comment Number: 4 Comment Originated: 02/14/2017
02/14/2017: Please show the correct ROW limits on the Utility Plans. This
project is dedicating extra ROW and should reflect what is on the Plat.
The ROW line has been added to the plans to match the Plat. Call outs have also been added.
Comment Number: 5 Comment Originated: 02/14/2017
02/14/2017: It looks like a sanitary sewer service is missing on Lot 1 and a
water service is missing on Lot 7.
The sanitary sewer for the existing house within Lot 1 will remain undisturbed and in use and therefore is not
shown. The water service for Lot 7 has been added to the Utility Plan.
Comment Number: 6 Comment Originated: 02/14/2017
02/14/2017: Per the Conceptual comments, a 6' detached walk is needed
south of the existing pedestrian ramp. This can be rebuilt with the new driveway
that is needed.
The design has been revised to include a 6’ detached walk.
Comment Number: 7 Comment Originated: 02/14/2017
02/14/2017: Please show the pipe outlet of Pond A to verify that drainage will
work in this area.
An outlet pipe has been added to outfall into a proposed 2’ pan and is shown and labeled in the plans.
Comment Number: 8 Comment Originated: 02/14/2017
02/14/2017: The existing sanitary sewer main will need to be in a Utility
Easement. The offsite drainage will also need to be in a Drainage Easement.
Please see the following link for the process for easement dedications:
http://www.fcgov.com/engineering/pdf/Easrowdedications2010.pdf . The fees
are $250 per easement and the recording fees will vary depending on the
number of pages. A deed and legals will be required for each easement,
Please see the following link for the Easement Dedication Application:
http://www.fcgov.com/engineering/pdf/TDRF2012applicationform.pdf
Please see the following link for the Easement Dedication sample Deed:
http://www.fcgov.com/engineering/pdf/ESMwithAdminAcceptance9111.doc
There is currently an existing 15’ Sanitary Sewer Easement that has been noted on the plans. As for the
outfall of Pond A and the need for a Drainage Easement, a Legal Description and Exhibit has been included
with the submittal. It is understood that this will be reviewed by the above described separate process, but is
hoped that this can happen concurrently with the Entitlement Process.
Comment Number: 9 Comment Originated: 02/14/2017
02/14/2017: The grading to the south of the property near the driveway seem
steep. How will this transition to the existing property to the south?
The steepest section south of the entrance is at 11%, which we don’t feel is too steep for earth grading. We
can discuss further if you still have concerns.
Page 3 of 14
Comment Number: 10 Comment Originated: 02/14/2017
02/14/2017: Are the Pond retaining walls going to be structural? There are
portions of the wall that are greater than 30". These will not be allowed within
easements.
All of the walls we are now proposing are below 30-inches. To achieve this height required for storage along
the southern property, we are now proposing a tiered system of 2 walls, none of which are greater than
30-inches.
Comment Number: 11 Comment Originated: 02/14/2017
02/14/2017: The lot that will have the offsite drainage has steep grades
towards the concrete pan. More spot elevations are needed to verify that the
public sidewalks will be to standard.
The grading within the lot east of the project has been revised. All grades are below 4:1 (25%) and labels
have been added to the plans.
Comment Number: 12 Comment Originated: 02/14/2017
02/14/2017: The sidewalk chase on Dover Drive will need to be reconfigured
so that the chase isn't within the Lot's driveway. Please see the LCUASS
dimensions for an attached sidewalk chase. There is a minimum 10' section
that is needed.
The driveway has been modified to allow for the complete 10-foot LCUASS section outside of the drive path.
A curbed concrete pan has been added to channel the flow into the sidewalk chase.
Comment Number: 13 Comment Originated: 02/14/2017
02/14/2017: The plat indicates that Tract A is a private access easement. Who
is the private access easement being dedicated to?
The definition of Tract A has been revised to include Utility, Drainage and Access.
Department: Environmental Planning
Contact: Stephanie Blochowiak, 970-416-4290, sblochowiak@fcgov.com
Topic: Landscape Plans
Comment Number: 1 Comment Originated: 02/13/2017
02/13/2017: Current proposed native seed mix is not appropriate for Fort
Collins ecotone and elevations (4,800 – 5,660 feet) nor are they considered
native. Additionally, hydro-seeding is not recommended. Provide scientific
names along with common names for native seed mix species, include percent
of each species, application rate for drill seed application and rate for
broadcast seed method (double drill seed rate). Consider mixes which include
all or most of the following: Buffalo grass (B. dactyloides); Sideoats grama (B.
curtipendula); Blue grama (B. gracilis); Alkali sacation (S. airoides); Western
wheatgrass (P. smithii); Switchgrass (P. virgatum); Sand Dropseed (S.
cryptandrus); Sixweeks fescue (V. octoflora).
Noted. Hydroseed note has been removed and a seed mix has been provided using most of the species
suggested, however, further discussion on the use and desired appearance is requested as we were not
able to speak before the re submittal.
Comment Number: 2 Comment Originated: 02/13/2017
02/13/2017: Report seeding rate in pounds per acre in addition to pounds per
square foot. Native Seed Mix pounds/acre drill seed application rate should be
at least 15 lbs/acre. If broadcast seed method is to be used double the drill
seed rate.
Page 4 of 14
Noted. This has been provided.
Comment Number: 3 Comment Originated: 02/13/2017
02/13/2017: Add Native Seed Mix notes to landscape plans.
a. NATIVE SEED SHALL BE PROVIDED BY (INSERT SEED MIX NAME AND
COMPANY FROM WHICH IT WILL COME FROM and COMPANY CONTACT
INFORMATION) AND THE GROUND SHALL BE CULTIVATED LIGHTLY
THEN SEEDED IN TWO DIRECTIONS TO DISTRIBUTE SEED EVENTLY
OVER ENTIRE AREA.
b. IF CHANGES ARE TO BE MADE TO SEED MIX BASED ON SITE
CONDITIONS APPROVAL MUST BE PROVIDED BY CITY ENVIRONMENTAL
PLANNER.
c. PRIOR TO SEEDING SOIL WILL BE AERATED AND SOIL AMENDMENTS
ADDED AS NECESSARY. APPROPRIATE NATIVE SEEDING EQUIPMENT
WILL BE USED (STANDARD TURF SEEDING EQUIPMENT SHALL NOT BE
USED).
d. DRILL SEED APPLICATION RECOMMENDED PER SPECIFIED
APPLICATION RATE TO NO MORE THAN 1 INCH DEPTH. FOR
BROADCAST SEEDING INSTEAD OF DRILL SEEDING METHOD - DOUBLE
SPECIFICIED APPLICATION RATE. REFER TO NATIVE SEED MIX TABLE
FOR SPECIES, PERCENTAGES AND APPLICATION RATES.
e. TREAT NATIVE SEED MIX AREA PRIOR TO INSTALLATION OF SEED
WITH APPROPRIATE HERBICIDE TO HELP CONTROL HERBACEOUS
WEED SPECIES. ONLY AFTER APPROPRIATE TIME PERIOD THEN
APPLY NATIVE SEED AS CALLED FOR ON APPROVED PLANS.
f. AFTER SEEDING THE AREA SHALL BE COVERED WITH CRIMPED
STRAW OR OTHER APPROPRIATE METHODS AND PROVIDED
TEMPORARY IRRIGATION UNTIL SEED IS ESTABLISHED. CONTRACTOR
SHALL MONITOR SEEDED AREA FOR PROPER IRRIGATION, EROSION
CONTROL, GERMINATION AND RESEEDING AS NEEDED TO ESTABLISH
COVER.
g. THE APPROVED SEED MIX AREA IS INTENDED TO BE MAINTAINED IN
A NATURAL-LIKE LANDSCAPE AESTHETIC. IF AND WHEN MOWING
OCCURS IN NATIVE GRASS SEED MIX AREAS DO NOT MOW LOWER
THAN 6-8 INCHES IN HEIGHT TO AVOID INHIBITING NATIVE PLANT
GROWTH.
h. NATIVE SEED AREA WILL BE CONSIDERED ESTABLISHED WHEN
SEVENTY-PERCENT TOTAL COVER IS REACHED WITH NO LARGER
THAN ONE FOOT SQUARE BARE SPOTS AND/OR UNTIL DEEMED
ESTABLISHED BY CITY PLANNING SERVICES.
These notes will be added to sheet L4 if the native seed is indeed used after we are able to discuss
further.
Page 5 of 14
Comment Number: 4 Comment Originated: 02/13/2017
02/13/2017: Revisit selections for deciduous shrubs. More native deciduous
shrubs are currently available commercially. Select shrubs appropriate for Fort
Collins ecotype and elevations. Many resources are available online including:
City of Fort Collins Natural Areas Department Native Plants List:
http://www.fcgov.com/naturalareas/pdf/nativeplants2013.pdf
City of Fort Collins Plant List:
http://www.fcgov.com/forestry/plant_list.pdf
Colorado Native Plant Society Suggested Native Plants:
https://conps.org/wp-content/uploads/2015/05/Suggested-Native-Plants_0408.
pdf
As mentioned in an email, the shrubs on the plant schedule are the Fort Collins approved plant list and
were chosen in part for their color and texture. The choices will be revisited once there is a definite
decision on the seed mix, but at the moment, we would like them to remain.
Department: Forestry
Contact: Molly Roche, , mroche@fcgov.com
Topic: Landscape Plans
Comment Number: 1 Comment Originated: 02/15/2017
02/15/2017:
Existing Trees
The proposed drainage swale on the North side of the property appears to be
quite close to some significant trees that are to be retained. To further evaluate,
Forestry requests that the applicant schedule a meeting with the City Forester to
review impact to tree roots. A meeting will be scheduled.
The three smaller Ash, along the northern boundary and closest to Taft Hill Road
are not numbered nor included in the tree mitigation table. Please include these
trees on the plans.
Per an email sent on 2/27, some of these trees are off of our property, but are noted in the legend
as "remaining". The other two trees on our property have been added to the table and accounted
for.
Tree #1 has a major trunk cavity and is potentially hazardous. City Forestry
recommends that this tree be removed for safety concerns.
This has been marked for removal.
If any off-site boundary trees will be removed by this project, then written
approval by the adjacent property owner should be provided and submitted to
the City Forester.
Noted.
Comment Number: 2 Comment Originated: 02/15/2017
02/15/2017:
Swamp White Oak is not adapted to soils in Fort Collins and do not survive
Page 6 of 14
long-term. Please change this species to a better adapted tree species such as
a Chinkapin Oak.
This has been changed to Chinkapin Oak.
The south street tree along Taft Hill Road is quite close to the gas line. Please
move it further to the south of the gas line to provide additional utility tree
separation.
The location has been adjusted to avoid the conflict.
Department: Historic Preservation
Contact: Maren Bzdek, 970-221-6206, mbzdek@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 02/15/2017
02/15/2017: The existing residence and associated garage at 2106 S. Taft Hill
Road were evaluated on January 20, 2017 to determine if the structures are
eligible for designation as local Fort Collins landmarks. The Director of CDNS
and a member of the Landmark Preservation Commission performed that
evaluation, which determined that both structures are fine examples of
streamline moderne architecture and are eligible for designation. The
determination was posted for 14 days to allow for appeal and no action was
taken during that period. That determination requires the subsequent
development on and near the parcel to be evaluated under Land Use Code
section 3.4.7.
Acknowledged.
Comment Number: 2 Comment Originated: 02/15/2017
02/15/2017: LUC 3.4.7 ensures that, to the maximum extent feasible, historic
sites and structures are preserved and incorporated into proposed
development and undertakings that may alter the characteristics of a historic
property must avoid adversely affecting the integrity of the property and respect
its character. Historic Preservation staff has met with the applicant and
discussed the particular importance of applying 3.4.7 to new construction on Lot
2 of the proposed development. Its abutting proximity to the historic buildings
will require a building design that meets the requirements of 3.4.7 regarding
height, setback, width, compatible design elements and building materials,
historic landscaping, and visual and pedestrian connections. The parties
agreed that a note would be added to the plat as well as the development
agreement that includes the following language: "As required by Land Use
Code section 3.4.7(F), the new construction on Lot 2 shall be similar to the
height, setback, and width of existing historic structures to the maximum extent
feasible, and shall be designed to be in character with same based on visual
elements such as window patterns and use of brick as the dominant building
material. In order to receive a building permit for Lot 2, a review for compliance
with 3.4.7 will be required and must also include a plan of protection for the
existing historic structures that specifies how they will be protected from
damage during construction."
Acknowledged. Further discussion was requested as the owner is willing to include language
on height, setback and width, but would like to strike the language pertaining to the character,
visual elements, window patterns and building materials in general as it is the owner's opinion that
this will put an unfair burden on the future owner of the lot and could potentially devalue the lot and
Page 7 of 14
and make it more difficult to sell.
Department: Light And Power
Contact: Todd Vedder, 970-224-6152, tvedder@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 02/15/2017
There is currently single phase and three phase power available to the north
along Taft Hill Rd
Acknowledged.
Comment Number: 2 Comment Originated: 02/15/2017
Streetlights will need to be placed along public streets. A 40 feet separation on
both sides of the light is required between shaded trees and streetlights. A 15
feet separation on both sides of the light is required between ornamental trees
and streetlights.
Due to the drive being private, no public lighting is proposed.
Comment Number: 3 Comment Originated: 02/15/2017
New development and system modification charges may apply. A link to our
online electric fee estimator is below.
http://www.fcgov.com/utilities/business/builders-and-developers/plant-investmen
t-development-fees/electric-development-fee-estimator?id=3
Acknowledged.
Comment Number: 4 Comment Originated: 02/15/2017
Please contact Light & Power if you have any questions. Please reference our
Electric Service Standards to ensure requirements are met. A copy of this link
is below.
http://www.fcgov.com/utilities/business/builders-and-developers/development-fo
rms-guidelines-regulations
Comment Number: 5 Comment Originated: 02/15/2017
Please provide the breaker panel size for each dwelling unit. Also inform if units
will be gas or electric heat.
A breaker panel size will need to be supplied at the time of the individual design of the single family units. At
this time, we do not have a design for the individual lots.
Comment Number: 6 Comment Originated: 02/15/2017
Please reference our Electric Service Standards and coordinate transformer
locations with Light & Power.
Acknowledge.
Comment Number: 7 Comment Originated: 02/15/2017
Please contact Todd Vedder with Light & Power Engineering Department if you
have any questions at 970.224.6152 or tvedder@fcgov.com
Acknowledge.
Department: PFA
Contact: Cal Sheesley, 970-416-2599, csheesley@poudre-fire.org
Page 8 of 14
Topic: General
Comment Number: 1 Comment Originated: 02/02/2017
02/02/2017: EMERGENCY ACCESS EASEMENT
The EAE as detailed on the plat appears to indicate two distinct access
easements: (1) All of Tract A and (2) The dead-end stub between Lots 4 & 5.
For simplicity, the limits of the EAE should be described as one dedication on
the plat, rather than two.
The Plat and the Utility Plans now show Tract A as being an Utility, Drainage and Access Easement. We
have also delineated a defined Emergency Access Easement to illustrate the required movement through
use of a hammer head design.
Comment Number: 2 Comment Originated: 02/02/2017
02/02/2017: DEAD-END FIRE LANES
Dead-end fire access roads exceeding 150' shall be provided with an approved
turnaround for fire apparatus. The cul-de-sac as shown has a 70' diameter
where 100' is the minimum allowable diameter (50' radius). If the intent is to
provide an alternative turnaround, that turnaround shall be designed to meet
minimum fire lane specifications.
At this time, a functional turnaround has not been achieved with this plan. The
35' dead-end stub, extending to the north is labeled as an EAE on the plat
however, it does not meet minimum dimensions for length, width, or turning
radii. The design is awkward and construction details were not provided to
indicate it will support 40 tons. Fire lane specifications are provided below for
planning purposes.
In addition to the design criteria already contained in relevant standards and
policies, any new fire lane must meet the following general requirements:
> Shall be designated on the plat as an Emergency Access Easement.
> Maintain the required 20 foot minimum unobstructed width & 14 foot minimum
overhead clearance.
> Be designed as a flat, hard, all-weather driving surface capable of supporting
40 tons.
> The required turning radii of a fire apparatus access road shall be a minimum
of 25 feet inside and 50 feet outside.
> Be visible by painting and/or signage, and maintained unobstructed at all
times. Sign locations or red curbing should be labeled and detailed on final
plans.
The above described Emergency Access Easement illustrates how the hammer head design is
accommodating the current standards. A hard surface will be designed to support 40-tons throughout the
movement.
Comment Number: 3 Comment Originated: 02/02/2017
02/02/2017: FIRE LANE SIGNS
The limits of the fire lane shall be fully defined throughout. Fire lane sign
locations should be indicated on future plan sets. Refer to LUCASS detail
#1418 for sign type. Appropriate directional arrows required on all signs. Code
language provided below.
> IFC D103.6: Where required by the fire code official, fire apparatus access
roads shall be marked with permanent NO PARKING - FIRE LANE signs
Page 9 of 14
complying with Figure D103.6. Signs shall have a minimum dimension of 12
inches wide by 18 inches high and have red letters on a white reflective
background. Signs shall be posted on one or both sides of the fire apparatus
road as required by Section D103.6.1 or D103.6.2.
“No Parking” signs have been added along the southern side of the private drive. We have also included
signage around the emergency backing area. Please see the Private Drive Street Plan and Profile.
Comment Number: 4 Comment Originated: 02/09/2017
02/09/2017: PAVERS
Fire lanes shall be designed as a flat, hard, all-weather driving surface capable
of supporting 40 tons. Private drives incorporating pavers as surface for fire
lanes shall provide geotech information confirming the paver design can handle
fire truck loading.
The pavers will be designed to support a 40 ton vehicle. Further geotechnical information can be provided at
Final Plans.
Comment Number: 5 Comment Originated: 02/09/2017
02/09/2017: LANDSCAPING
The Landscape Plan indicates proposed trees canopies encroaching on the
fire lane. The fire lane shall remain unobstructed at all times to a height of 14'
and mature trees will need to be trimmed within the fire lane. This comment
should be reflected in the development agreement and included as part of the
HOA. Otherwise, PFA recommends substituting a different tree species or
variety.
Tree location was adjusted to avoid encroachment.
Comment Number: 6 Comment Originated: 02/09/2017
02/09/2017: WATER SUPPLY
Hydrant spacing and flow must meet minimum requirements based on type of
occupancy. Hydrants are required on 800' centers in residential areas. The
hydrant on the cul-de-sac is located appropriately so as to serve the planned
development on the private drive, but due to the separation distances between
hydrants along Taft Hill Road (approximately 1,900'), an additional fire hydrant
will be required on Taft Hill Road.
A Fire hydrant has been added at drive entrance to divide the span between the two existing fire hydrants.
Comment Number: 7 Comment Originated: 02/09/2017
02/09/2017: PREMISE IDENTIFICATION
Unless the private drive is named, a monument sign WILL be required.
The private drive will be named, but it has not yet been determined.
Department: Planning Services
Contact: Meaghan Overton, 970-416-2283, moverton@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 02/13/2017
02/13/2017: From the Streets department - "Please request that the developer
redesign the entrance so that the sidewalk will be detached and behind the
entrance approach. This will be safer for pedestrians because they will be
farther from traffic and will also keep the sidewalk free of water and ice. The
detached sidewalk condition is a standard detail for development. This allows
the vehicle entrance to remain steep and thus keep water in the flowline; as
currently shown, the sidewalk would have to be depressed to maintain the 2%
Page 10 of 14
ADA cross slope and would inevitably fill with water, ice, and debris. There
appears to be enough ROW available to the south to allow for this design." See
sketch redlines.
The entrance and sidewalks have been re designed.
Comment Number: 3 Comment Originated: 02/14/2017
02/14/2017: The existing home on the site is greater than 50 years in age, and
will need to be evaluated through the historic preservation demolition/alteration
review process. In addition, notes will need to be added to the Development
Agreement and the Plat regarding the review process for development on Lot 2.
Please see comments from historic preservation.
Acknowledged. See response under Historic Preservation above.
Topic: Landscape Plans
Comment Number: 8 Comment Originated: 02/14/2017
02/14/2017: Please correct the number of mitigation trees required/provided
on Sheets L1 and L2. According to the Tree Mitigation Table, 13 mitigation
trees are required, not 23. I counted 17 mitigation trees being provided, not 23.
See redlines.
This has been corrected to 17 with 17 mitigation trees being provided.
Topic: Modification of Standard
Comment Number: 5 Comment Originated: 02/14/2017
02/14/2017: On a cul-de-sac, lot width can be measured at the actual front
building line rather than the 20 foot setback. You may wish to revise the
modification request and site plan to show the lot width at the building line. If you
choose to do that, however, please note that you will need to add a building
envelope to the site plan.
We will leave the modification request as-is.
Topic: Site Plan
Comment Number: 2 Comment Originated: 02/14/2017
02/14/2017: Each single family dwelling must provide at least one off street
parking space. The site plan doesn't designate any parking spaces, so please
remove the "parking summary" from the site plan and instead add to the site
plan notes: "All single family detached homes shall meet or exceed the
residential parking standards as outlined in 3.2.2(K) of the Land Use Code."
The parking summary has been removed and a note added to the site plan notes on sheet CS.
Comment Number: 4 Comment Originated: 02/14/2017
02/14/2017: 3.6.2(G) Lots having a front or rear lot line that abuts an arterial
street shall have a minimum depth of 150 feet. The front lot line is measured
from the primary entrance and/or the lot line from which the lot takes its address,
which means that Lot 1 is out of compliance with 3.6.2(G). Please add
buffering/enhanced landscaping to Lot 1 and submit a brief request for
alternative compliance. The request should emphasize that the existing building
on Lot 1 is an existing condition, that enhanced landscaping and street trees
are being provided along the arterial street, and that the proposed lot
configuration functions as well or better than a configuration that would meet the
standard as written.
Alternative compliance request is a part of this submittal and additional landscape has been provided along
Taft Hill Road.
Page 11 of 14
Comment Number: 6 Comment Originated: 02/14/2017
02/14/2017: Cul de sacs are required to be 100 feet in diameter for fire
access. See comments from Poudre Fire Authority for further details. If a
code-compliant cul-de-sac can not be constructed, you may wish to consider a
hammerhead design to accommodate the required fire access.
An emergency access easement exhibit has been provided to illustrate the hammerhead, see sheet S2.
This was reviewed by PFA offline who gave additional comments, which have been accommodated.
Comment Number: 7 Comment Originated: 02/14/2017
02/14/2017: Please add to the site plan notes: "All single family detached
homes shall meet or exceed the garage door standards as outlined in 3.5.2(F)
of the Land Use Code."
This note added to the site plan notes on sheet CS.
Department: Stormwater Engineering
Contact: Jesse Schlam, 970-218-2932, jschlam@fcgov.com
Topic: Erosion Control
Comment Number: 1 Comment Originated: 02/06/2017
02/06/2017: The site disturbs more than 10,000 sq. ft., therefore Erosion and
Sediment Control Materials need to be submitted for FDP. The erosion control
requirements are in the Stormwater Design Criteria under the Amendments of
Volume 3 Chapter 7 Section 1.3.3. Current Erosion Control Materials
Submitted do not meet requirements. Please submit; an Erosion Control Plan
(based upon redlines returned), an Erosion Control Report (not included in
submitted material), and an Escrow / Security Calculation (not included in
submitted material). Also, based upon the area of disturbance State permits for
stormwater will be required since the site is over an acre. If you need
clarification concerning the erosion control section, or if there are any questions
please contact Jesse Schlam 970-218-2932 or email @ jschlam@fcgov.com
An Erosion Control Report and Escrow will be provided at Final. All redlines received have been revised.
Contact: Wes Lamarque, 970-416-2418, wlamarque@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 02/14/2017
02/14/2017: The detention basins and the LID swale need to be in separate
tracts and drainage easements.
Comment Number: 2 Comment Originated: 02/14/2017
02/14/2017: The LID swale along the north property line needs to be designed
with the full media section and underdrain. Also, a drywell will need to be
included due to not having an outfall for the underdrain into the detention basin.
An underdrain system has been proposed along the entire length of the Bioswale. The underdrain system is
proposed to terminate into a drywell located at the end of the Bioswale section.
Comment Number: 4 Comment Originated: 02/17/2017
02/17/2017: The retaining wall is near 4 feet in some locations where a
separate building permit and a structural analysis will be required.
All of the walls we are now proposing are below 30-inches. To achieve this height required for storage along
the southern property, we are now proposing a tiered system of 2 walls, none of which are greater than
30-inches.
Page 12 of 14
Comment Number: 5 Comment Originated: 02/17/2017
02/17/2017: The detention ponds need to meet the Detention Pond Landscape
Standards.
The ponds have been regraded to supply undulating slopes and avoid a consistent 4:1 downward grade.
Comment Number: 6 Comment Originated: 02/17/2017
02/17/2017: The retaining wall (including any footers) must be entirely located
on the property. The south retaining wall may need to be moved north to
accommodate the footers.
Due to the revised height of the walls, footer will not be required and will remain entirely on-site.
Comment Number: 7 Comment Originated: 02/17/2017
02/17/2017: Please document the conveyance of the 100-year storm into the
detention basins. No curb cuts or chases were shown.
A 5’ curb cut has been added to the plans to allow for conveyance of the 100-year storm into Pond B.
Department: Technical Services
Contact: Jeff County, 970-221-6588, jcounty@fcgov.com
Topic: Construction Drawings
Comment Number: 9 Comment Originated: 02/17/2017
02/17/2017: Please revise the Benchmark Statement as marked. See redlines.
This has been revised.
Comment Number: 10 Comment Originated: 02/17/2017
02/17/2017: The Basis Of Bearings statement should match the Subdivision
Plat.
This has been revised.
Comment Number: 11 Comment Originated: 02/17/2017
02/17/2017: There are line over text issues. See redlines.
These have been revised.
Comment Number: 12 Comment Originated: 02/17/2017
02/17/2017: Please tie the coordinate values shown for utilities to the project
boundary. We would prefer that this be done by adding property corner values
to each sheet, or showing the property corner values on the horizontal control
plans and adding a note to each sheet with coordinate values.
Comment Number: 13 Comment Originated: 02/17/2017
02/17/2017: There is text that needs to be masked. Mask all text in hatched
areas. See redlines.
This has been revised
Topic: Landscape Plans
Comment Number: 7 Comment Originated: 02/17/2017
02/17/2017: Please change the title to match the Subdivision Plat. See
redlines.
This has been revised
Comment Number: 8 Comment Originated: 02/17/2017
02/17/2017: Please remove the address from the title block. With the project
being replatted, the address could change.
This has been revised
Page 13 of 14
Topic: Plat
Comment Number: 1 Comment Originated: 02/17/2017
02/17/2017: Please make changes as marked. If changes are not made or you
disagree with comments, please provide written response of why corrections
were not made. Please provide any responses on redlined sheets and/or in
response letter.
The Plat has been revised.
Topic: Site Plan
Comment Number: 2 Comment Originated: 02/17/2017
02/17/2017: Some of the sheet numbers in the sheet index do not match the
sheet numbers on the noted sheets. See redlines.
This has been revised.
Comment Number: 3 Comment Originated: 02/17/2017
02/17/2017: Please revise the legal description as marked. See redlines.
This has been revised.
Comment Number: 4 Comment Originated: 02/17/2017
02/17/2017: Please change the title to match the Subdivision Plat. See
redlines.
This has been revised.
Comment Number: 5 Comment Originated: 02/17/2017
02/17/2017: Please remove the address from the title block. With the project
being replatted, the address could change.
This has been revised.
Comment Number: 6 Comment Originated: 02/17/2017
02/17/2017: There are cut off text issues. See redlines.
This has been revised.
Department: Traffic Operation
Contact: Nicole Hahn, 970-221-6820, nhahn@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 02/15/2017
02/15/2017: The proposed access is located within the signal stop threshold.
We will need to work with you to determine the treatment at the access to alert
drivers to the activated HAWK signal.
Until a firm plan is in place, a note has been added to the Street Plan and Profile to rotate the existing Hawk
Light to allow for vehicles on both Taft Hill Road and the Private Drive to utilize the same warning signal.
Department: Water Conservation
Contact: Eric Olson, 970-221-6704, eolson@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 02/16/2017
02/16/2017: Irrigation plans are required no later than at the time of building
permit. The irrigation plans must comply with the provisions outlined in Section
3.2.1(J) of the Land Use Code. Direct questions concerning irrigation
requirements to Eric Olson, at 221-6704 or eolson@fcgov.com
Acknowledged.
Page 14 of 14
Department: Water-Wastewater Engineering
Contact: Wes Lamarque, 970-416-2418, wlamarque@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 02/14/2017
02/14/2017: Please add a water service to Lot 7.
The water service to Lot 7 has been added to the Utility Plan.
Comment Number: 2 Comment Originated: 02/17/2017
02/17/2017: The water main can be 6-inches in diameter due to the minimal
lots for water quality reasons.
The water main has been revised on the Utility Plan.
Comment Number: 3 Comment Originated: 02/17/2017
02/17/2017: The west sanitary sewer manhole needs to be relocated out of the
curb & gutter.
The sanitary sewer alignment has been revised to be out of the proposed curb and gutter section.
Department: Zoning
Contact: Marcus Glasgow, 970-416-2338, mglasgow@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 02/13/2017
02/13/2017: Please add summary to site plan with typical building setbacks.
This will be added.
Comment Number: 2 Comment Originated: 02/13/2017
02/13/2017: Please add note to site plan for garage door standards.
This has been added to the site plan notes on sheet CS.