HomeMy WebLinkAboutRAW URTH DESIGNS - PDP - PDP150007 - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTSITEM NO 1
MEETING DATE Nov. 2, 2015
STAFF Clay Frickey
ADMINISTRATIVE HEARING OFFICER
Planning Services 281 N College Ave – PO Box 580 – Fort Collins, CO 80522-0580
fcgov.com/developmentreview/ 970.221.6750
STAFF REPORT
PROJECT: Raw Urth Designs, PDP150007
APPLICANT: Curtis Koldeway
Hauser Architects
3780 E 15th St.
Loveland CO, 80538
OWNERS: Sasick Properties LLC
PO Box 369
Bellvue, CO 80512
PROJECT DESCRIPTION:
This is a request for a Project Development Plan for Raw Urth Designs to construct a
two story, 15,405 square foot building. The proposed building will be used by a metal
fabrication company that will be relocating from their existing building in Bellvue. Within
the new building will be a showroom to display work for builders and designers, offices,
an art gallery, and their metal fabrication shop. The building is located on the northwest
corner of Conifer Street and Red Cedar Drive. The north side of the building will contain
a privacy fence to screen their on-site storage, dumpster, and mechanical equipment.
The parcel is located in the (I) Industrial zone district.
RECOMMENDATION: Staff recommends approval of Raw Urth Designs, PDP150007.
EXECUTIVE SUMMARY:
Staff finds the proposed Raw Urth Designs Project Development Plan complies with the
applicable requirements of the City of Fort Collins Land Use Code (LUC), more
specifically:
The Project Development Plan complies with the process located in Division 2.2
– Common Development Review Procedures for Development Applications of
Article 2 – Administration.
The Project Development Plan complies with relevant standards of Article 3 –
General Development Standards.
Staff Report – Raw Urth Designs, PDP150007
Administrative Hearing 11-02-2015
Page 2
The Project Development Plan complies with relevant standards located in
Division 4.28 Industrial (I) of Article 4 – Districts.
COMMENTS:
1. Background
The property was annexed into the City of Fort Collins as part of the Pine Tree Park
Annexation in November 1972. The site was originally platted as Lot 20 of the
Evergreen Park Replat in March 1974.
The surrounding zoning and land uses are as follows:
Direction Zone District Existing Land Uses
North Industrial (I) Light industrial, office
South Service Commercial (CS), Community
Commerical – North College (CCN) Retail, residential
East Industrial (I) Outdoor storage, vehicle repair, day shelter
West Service Commercial (CS) Motel, vehicle repair
A zoning and site vicinity map is presented on the following page.
Staff Report – Raw Urth Designs, PDP150007
Administrative Hearing 11-02-2015
Page 3
Figure 1: Raw Urth Designs Zoning & Site Vicinity
Staff Report – Raw Urth Designs, PDP150007
Administrative Hearing 11-02-2015
Page 4
2. Compliance with Article 3 of the Land Use Code – General Development
Standards:
The project complies with all applicable General Development Standards as
follows:
A. Division 3.2.1 – Landscaping and Tree Protection
The proposed landscaping is consistent with requirements of the Land
Use Code in regards to the addition of street trees, parking lot
landscaping, and landscape screening from adjacent uses.
B. Section 3.2.2(C)(4)(b) - Bicycle Parking Space Requirements
The minimum number of bicycle parking spaces required for Industrial
uses is 4. The Raw Urth site will provide one bike rack that contains 5
bicycle parking spaces.
C. Section 3.2.2(C)(5) - Walkways
Walkways must be provided to link sidewalks with building entries through
parking lots. These walkways must also provide direct connections to off-
site pedestrian and bicycle destinations. The Raw Urth site provides a
connecting walkway that runs along the southern perimeter of the parking
lot that satisfies this standard.
D. Section 3.2.2(D)(1) - Access and Parking Lot Requirements;
Pedestrian/Vehicle Separation
To the maximum extent feasible, pedestrians and vehicles shall be
separated through provision of a sidewalk or walkway. Where complete
separation of pedestrian and vehicles is not feasible, potential hazards
shall be minimized by using landscaping, bollards, special paving, lighting,
and other means to clearly delineate pedestrian areas. Raw Urth
separates pedestrians from vehicles by providing a sidewalk separated
from the driving and parking area via curb.
E. Section 3.2.2(E) - Parking Lot Layout
The proposed parking lot layout is consistent with requirements of the
Land Use Code in regards to circulation routes, orientation, landscaped
islands, and points of conflict.
Staff Report – Raw Urth Designs, PDP150007
Administrative Hearing 11-02-2015
Page 5
F. Section 3.2.2(J) - Setbacks
The proposed parking lot is setback further than the 10-foot minimum from
non-arterial streets and 5-foot minimum along a lot line required per the
Land Use Code.
G. Section 3.2.2(K)(2) – Nonresidential Parking Requirements
The minimum, maximum, and proposed parking are contained in the
tables below. Raw Urth is providing parking within the range of required
parking and thus meets the requirements of the Land Use Code.
Table 1: Raw Urth Parking
Use Min. Parking Max. Parking Parking
Provided
Industrial (17
employees)
.5 per employee =
9 spaces
.75 per employee
= 13 spaces
9 spaces
H. Section 3.2.2(K)(5) - Handicap Parking
Parking lots with less than 25 spaces must provide at least 1 handicap
parking space. The parking lot proposed is less than 25 spaces and
provides 1 handicap parking space.
I. Section 3.2.3 - Solar Access, Orientation, Shading
All developments must be designed to accommodate active and/or
passive solar installations and must not deny adjacent properties access
to sunshine. The proposed building is designed and located to minimize
the casting of shadows on adjacent properties and could accommodate
future active and/or passive solar installations.
J. Section 3.2.4 - Site Lighting
The proposed lighting plan is consistent with the requirements of the Land
Use Code in regards to the general standard, lighting levels, and design
standards.
K. Section 3.2.5 - Trash and Recycling Enclosures
Trash and recycling enclosures must be provided in locations abutting
refuse collection or storage areas, designed to allow walk-in access
without having to open the main service gate, screened from public view,
Staff Report – Raw Urth Designs, PDP150007
Administrative Hearing 11-02-2015
Page 6
and constructed on a concrete pad. The proposed trash and recycling
enclosure design satisfies the standards.
L. Section 3.5.1(E) - Building Materials
All proposed buildings shall use similar materials to existing buildings in
the neighborhood or use similar architectural characteristics if dissimilar
materials are proposed. The proposed building uses similar materials and
architectural details to the existing buildings in the area. The proposed
materials include split face concrete masonry units, metal roofing,
decorative wood lattice, and sun shades.
M. Section 3.5.1(I) - Outdoor Storage Areas/Mechanical Equipment
The proposed plan is consistent with the requirements of the Land Use
Code in regards to the location of outdoor storage, screening of storage
areas, and screening of rooftop mechanical equipment from public view.
N. Section 3.6.6 – Emergency Access
For the Raw Urth site, an emergency access easement is proposed that
runs through the parking lot entrance to the northern edge of the site with
a turnaround located in the paved outdoor storage area. The emergency
access easement ensures emergency vehicles can gain proper access
and maneuvering to reach all portions of the proposed building.
3. Compliance with Article 4 of the Land Use Code – Industrial (I), Division
4.28:
The project complies with all applicable Article 4 standards as follows:
A. Section 4.28(B)(2) – Permitted Uses
The proposed uses, light industrial and office, are permitted in the
Industrial zone district and are consistent with the district’s intent to
provide a wide range of commercial and industrial operations.
B. Section 4.28(D)(1) – Dimensional Standards
Non-residential structures are limited to four stories in height. The Project
Development Plan/Final Plan proposes a two-story structure.
Staff Report – Raw Urth Designs, PDP150007
Administrative Hearing 11-02-2015
Page 7
C. Section 4.28(E)(2)(b) – Development Standards – Orientation
Along arterial streets, buildings shall be sited so that a building abuts the
required thirty-foot deep landscaped yard for at least 30% of the building
frontage. This building face may not consist of a blank wall. The entire
building’s southern side abuts the landscape yard and features a series of
architectural features including windows, changes of plane, changes of
materials, and varied roof lines to break up the mass.
D. Section 4.28(E)(2)(c) – Development Standards – Building Character and
Color
New building color shades shall be neutral, with a medium or dark color
range, and not white, bright or reflective. The proposed materials are all
neutral and are not white, bright or reflective.
E. Section 4.28(E)(3)(a)(2) – Development Standards – Screening
The property abuts a non-residential zone district boundary and arterial
street to the south, which necessitates a thirty-foot deep landscape yard.
The proposed landscape yard is thirty feet in depth and provides ample
landscape features to act as a buffer to the industrial activity on-site.
F. Section 4.28(E)(3)(b) – Storage and Operational Areas
Storage, loading and work operations must be screened from view along
district boundary lines and public streets in the I District. The proposed
site plan shows a 6-foot high solid fence surrounding the storage, loading
and work area.
4. Findings of Fact/Conclusion:
In evaluating the request for the Raw Urth Designs, PDP150007, Staff makes the
following findings of fact:
A. The Project Development Plan complies with process located in Division
2.2 – Common Development Review Procedures for Development
Applications of Article 2 – Administration.
B. The Project Development Plan complies with relevant standards located in
Article 3 – General Development Standards.
C. The Project Development Plan complies with relevant standards located in
Division 4.28 Industrial (I) of Article 4 – Districts.
Staff Report – Raw Urth Designs, PDP150007
Administrative Hearing 11-02-2015
Page 8
RECOMMENDATION:
Staff recommends approval of the Raw Urth Designs, PDP150007.
ATTACHMENTS:
1. Zoning & Site Vicinity Map
2. Applicant’s Statement of Planning Objectives
3. Raw Urth Planning Document Set (Site Plan, Landscape Plan, Elevations &
Photometric Plan)