HomeMy WebLinkAboutWEST PLUM HOUSING - FDP - FDP160048 - PLANS - UTILITY PLANS40' FL - FL
20' FL - CROWN 20' FL - CROWN
\A1;20' FL - CROWN
PROPOSED PLUM STREET
(66' ROW)
PROPOSED
BUILDING
12' TRAVEL
LANE
30" VERTICAL
CURB & GUTTER
30" VERTICAL
CURB & GUTTER
EXISTING ±57.5' ROW
NORTH RIGHT-OF-WAY
12' TRAVEL
LANE
8' BIKE/
PARKING
8' BIKE/
PARKING
ADD'L
±8.5'
ROW
PROPOSED ±66' ROW
SOUTH RIGHT-OF-WAY
9' UTIL &
ACCESS
ESMT
EXISTING
BUILDING
4'
MIN.
EXISTING ±43' FL - FL
± 21.5' FL - CROWN ± 21.5' FL - CROWN
\A1;%%P 21.5' FL - CROWN
PROPOSED CITY PARK AVE
(ROW VARIES)
PROPOSED
BUILDING
EXISTING 30" VERTICAL
CURB & GUTTER
PROPOSED ROW (WIDTH VARIES)
EAST RIGHT-OF-WAY
9' UTIL &
ACCESS
ESMT
7' WALK
(5' WITHIN ROW)
8' PARKWAY
EXISTING WALK
(6' WITHIN ROW)
EXISTING 7' PARKWAY
6' WALK
(4.5' WITHIN ROW)
8' PARKWAY
WEST RIGHT-OF-WAY
EXISTING 4' WALK
(ATTACHED)
No. Revisions:
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
A. GENERAL NOTES
1. All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer
County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the
specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort
Collins.
2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise.
3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer.
Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of
any work shown in these plans.
4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as
beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins
Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer
hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and
demands which may arise from any errors and omissions contained in these plans.
5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and
specifications current at the date of approval of the plans by the City of Fort Collins Engineer.
6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of
the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The
Developer shall be responsible for unknown underground utilities.
7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning
excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be
located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be
the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans.
8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any
utility crossings required.
9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer
to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction.
10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is
accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all
parties affected by any disruption of any utility service as well as the utility companies.
11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider.
Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a
pre-construction meeting may be required prior to commencement of any work.
12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary
G
S
S
T
M
LID
WV
H
Y
D
H
Y
D
WV
WV
E
/ / / / / / / / / / / / / / / /
/ / / / / / / /
/ / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / /
/ / / / / / / /
/ / / / / / / / / / / / / / / /
X
X
X
X
X
X
X
X
X X
X X
X
X
X
X
X X
X
X
X X
X X
X
X
X
X X
X
X
X X
X
T T T T T T T
G G G G G G G
G G G G G
T T T T T T
CTV CTV CTV CTV
OHU OHU
OHU OHU
OHU
OHU OHU
OHU
9' UTILITY EASEMENT
9' UTILITY EASEMENT
5' UTILITY EASEMENT
UTILITY EASEMENT
T
/ / / / / / / / / / / / / / / /
/ / / / / / / /
/ / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / /
/ / / / / / / /
/ / / / / / / / / / / / / / / /
X
X X
X X
X
X
X
X X
X
X
X X
X
VAULT
ELEC
T FO
T
FO
ELEC
VAULT
ELEC
/ / / / / / / /
/ / / / / / / /
/ / / / / / / /
X
X
X
VAULT
ELEC
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
VAULT
ELEC FO
VAULT
ELEC
T FO
E
X
PROPOSED 1'
SIDEWALK CHASE PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
S
S
T
WV
H
Y
D
H
Y
D
WV
WV
/ / / / / / / / / / / / / / / /
/ / / / / / / /
/ / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / /
/ / / / / / / /
/ / / / / / / / / / / / / / / /
X
X X
X X
X
X
X
X X
X
X
X X
X
T T T T T T T
G G G G G G G
G G G G G
T T T T T T
CTV CTV CTV CTV
SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS SS
SS SS
W
W W W W W W
W
W
W
VAULT
ELEC
S
T FO
T
FO
ELEC
VAULT
ELEC W
W
ST
/ / / / / / / /
G G
E E
E
E E
E
E
F F
F
E
F
F
S
WV
H
Y
D
H
Y
D
WV
/ / / / / / / /
/ / / / / / / /
/ / / / / / / /
/ / / / / / / / / / / / / / / /
/ / / / / / / /
/ / / / / / / /
/ / / / / / / / / / / / / / / /
/ / / / / / / /
/ / / / / / / / / / / / / / / /
X
X
X
X X
X
X
X
X
T
T T T T T
G
G G
G G G
T
T T T
SS SS SS SS
SS
SS
SS
W W
W
W
W
W
W
W
V
AULT
ELEC
X
W
T
/ / / / / / / / / / / / / / / /
/ / / / / / / /
/ / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / /
/ / / / / / / /
/ / / / / / / / / / / / / / / /
X
X X
X X
X
X
X
X X
X
X
X X
X
T T T T T T T
T T T T T T
VAULT
ELEC
T FO
T
FO
ELEC
VAULT
ELEC
ST
/ / / / / / / /
/ / / / / / / /
/ / / / / / / /
X
X
X
VAULT
ELEC
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
VAULT
ELEC FO
VAULT
ELEC
T FO
E
X
X
X X X X
X X X X X
X X X X
X X X X X
X X X X X
X X X X X X
UTILITY EASEMENT
PROPOSED 5'
WALK w/ PAN
CITY PARK CONDOMINIUMS
(BOOK 1291, PAGE 862)
FFE=41.25
40.47
41.47
41.47
40.57
40.53
40.73
40.64
41.06
43.03
40.85
40.98
43.03
43.03
43.03
41.10
41.15
41.10
40.91
40.83
40.86
41.03
41.06
41.17
41.13
43.03
43.07
41.07
40.68
41.56
41.56
40.62
40.71
41.06
41.20
41.25
41.21 41.25
41.17
41.39
41.75
41.75
41.04
40.92
40.92
42.08
41.80
41.90
41.04
FFE=41.25 FFE=41.25 FFE=41.25
/ / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / /
X X X
X X
X X X X
X X X
X X X
X X
X X
X X
X X X
X X X X
X X
X
TF
FDC
TOWN SQUARE
CONDOMINIUMS
FFE=39.30
(39.02) 41.25
41.15
39.56
39.58
39.68
39.65
39.74
40.02
39.89
40.02
40.34
40.25
41.58
41.49
41.90
41.80
41.81
41.99
38.36
38.27
38.27
38.36
41.88
43.00
43.55
36.95
36.78
36.86
36.86
35.83
35.62
36.64
36.80
41.38
41.37
5030
5035
5040
5045
5050
5030
5035
5040
5045
5050
9+50 10+00 11+00 12+00 13+00 14+00 14+50
5038.22
5037.94
5037.72
5037.54
5037.35
5037.17
5036.99
5036.81
5036.67
5036.53
5036.39
5036.24
5035.94
5035.62
5035.30
5034.98
-1.10%
-0.74%
0.34% -1.30%
-1.27%
-0.56%
-0.95%
-1.23%
-1.25%
-1.29%
-1.27%
-1.28%
-1.30%
PVI STA = 10+00.00
PVI ELEV = 5038.22
PVI STA = 10+34.67
PVI ELEV = 5037.84
PVI STA = 11+70.88
PVI ELEV = 5036.83
PVI STA = 12+74.14
PVI ELEV = 5036.25
PVI STA = 12+75.26
PVI ELEV = 5036.23
PVI STA = 12+73.26
PVI ELEV = 5036.25
PVI STA = 12+72.14
PVI ELEV = 5036.26
PVI STA = 12+79.81
PVI ELEV = 5036.19
PVI STA = 12+90.88
PVI ELEV = 5036.06
PVI STA = 12+94.81
PVI ELEV = 5036.01
PVI STA = 13+02.97
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
C600
UTILITY DETAILS
A. Reese
B. Ruch
N/A
No. Revisions:
By: Date:
REVIEWED BY:
N. Haws
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
Feb. 22, 2017
PROJECT:
1252-001
Sheet
of 17 Sheets
WEST PLUM HOUSING
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
02/22/17
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
C601
UTILITY DETAILS
A. Reese
B. Ruch
N/A
No. Revisions:
By: Date:
REVIEWED BY:
N. Haws
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
Feb. 22, 2017
PROJECT:
1252-001
Sheet
of 17 Sheets
WEST PLUM HOUSING
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
02/22/17
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
C602
STORMWATER DETAILS
A. Reese
B. Ruch
N/A
No. Revisions:
By: Date:
REVIEWED BY:
N. Haws
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
Feb. 22, 2017
PROJECT:
1252-001
Sheet
of 17 Sheets
WEST PLUM HOUSING
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
02/22/17
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
NOT TO SCALE
300
C602
STORMWATER BEDDING
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
C603
SITE DETAILS
A. Reese
B. Ruch
N/A
No. Revisions:
By: Date:
REVIEWED BY:
N. Haws
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
Feb. 22, 2017
PROJECT:
1252-001
Sheet
of 17 Sheets
WEST PLUM HOUSING
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
02/22/17
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
NOT TO SCALE
400
C603
CURB AND GUTTER
UD UD UD UD UD UD
FDC
FDC
X
X X
X X
X
X
X
X X
X
X
X X
X
VAULT
ELEC
FO
FO
ELEC
VAULT
ELEC
ST
X
X
X
VAULT
ELEC
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
VAULT
ELEC FO
VAULT
ELEC
FO
E
X
X
X
X
X
X
D D
D
TF
PLUM STREET
(ROW VARIES)
9' UTILITY EASEMENT
PROPOSED CONCRETE
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
C701
EROSION CONTROL DETAILS
A. Reese
B. Ruch
N/A
No. Revisions:
By: Date:
REVIEWED BY:
N. Haws
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
Feb. 22, 2017
PROJECT:
1252-001
Sheet
of 17 Sheets
WEST PLUM HOUSING
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
02/22/17
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
UD UD UD UD UD UD
FDC
FDC
T
X
X X
X X
X
X
X
X X
X
X
X X
X
T T T T T T T
T T T T T T
VAULT
ELEC
T FO
T
FO
ELEC
VAULT
ELEC
ST
X
X
X
VAULT
ELEC
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
VAULT
ELEC FO
VAULT
ELEC
T FO
E
X
X
X
X
X
X
D D
D
TF
PLUM STREET
(ROW VARIES)
9' UTILITY EASEMENT
PROPOSED CONCRETE
COLLAR & CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 5'
WALK w/ PAN
PROPOSED 1'
SIDEWALK CHASE PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
9' UTILITY EASEMENT
5' UTILITY EASEMENT
UTILITY EASEMENT
THE LOFTS AT CAMPUS WEST
TOWN SQUARE
CONDOMINIUMS
CITY PARK CONDOMINIUMS
(BOOK 1291, PAGE 862)
THE DISTRICT AT CAMPUS WEST
(REC. NO. 20130032356)
5' UTILITY EASEMENT
PROPOSED
STORM DRAIN
OPEN BOTTOM
DETENTION VAULT
3
2
1
4
PROPOSED
OUTLET STRUCTURE
PROPOSED
TRENCH DRAIN
PROPOSED
TRENCH DRAIN
1
0.76
2
0.36
4
3 0.03
0.13
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
C800
DRAINAGE EXHIBIT
A. Reese
B. Ruch
1"=20'
No. Revisions:
By: Date:
REVIEWED BY:
N. Haws
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
Feb. 22, 2017
PROJECT:
1252-001
Sheet
of 17 Sheets
WEST PLUM HOUSING
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
02/22/17
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
NORTH
( IN FEET )
1 inch = ft.
20 0 20 Feet
20
40 60
LEGEND:
4953
PROPOSED CONTOUR
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED INLET
DESIGN POINT A
FLOW ARROW
DRAINAGE BASIN LABEL
DRAINAGE BASIN BOUNDARY
PROPOSED SWALE SECTION
1 1
NOTES:
1. REFER TO THE FINAL DRAINAGE REPORT FOR WEST PLUM HOUSING, DATED
FEBRUARY 22, 2017 FOR ADDITIONAL INFORMATION.
BASIN
DESIGNATION
AREA BASIN (AC)
BENCHMARK
FOR DRAINAGE REVIEW ONLY
NOT FOR CONSTRUCTION
C
0.60 ac
PROJECT DATUM: NAVD88
CITY OF FORT COLLINS BENCHMARK 19-97
AT THE SOUTHEAST CORNER OF WEST ELIZABETH AND SHIELDS ST., ON A CONCRETE
TRAFFIC SIGNAL BASE.
ELEV.=5025.74
CITY OF FORT COLLINS BENCHMARK 3-08
SOUTHWEST CORNER OF MULBERRY ST. AND SHIELDS ST. ON A CONCRETE TRAFFIC
SIGNAL BASE.
ELEV.=5030.29
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM.
SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL
DATUMS.
IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING
EQUATION SHOULD BE USED:
NGVD29 UNADJUSTED = NAVD88 - 3.17'
BASIS OF BEARINGS
THE BASIS OF BEARINGS IS THE SOUTH LINE OF THE NORTHEAST QUARTER OF SECTION
15, AS BEARING SOUTH 89°04'20" EAST.
DEVELOPED RUNOFF SUMMARY TABLE
BASIN
ID
TOTAL
AREA
(acres)
C2 C10 C100 2-yr Tc
(min)
10-yr Tc
(min)
100-yr Tc
(min)
Q2
(cfs)
Q10
(cfs)
Q100
(cfs)
1 0.76 0.95 0.95 1.00 6.8 6.8 5.7 1.87 3.20 7.35
2 0.36 0.63 0.63 0.79 12.0 12.0 11.4 0.48 0.82 2.14
3 0.13 0.15 0.15 0.19 8.4 8.4 7.9 0.05 0.08 0.21
4 0.03 0.15 0.15 0.19 5.6 5.6 5.2 0.01 0.02 0.06
On-Site LID Treatment
Project Summary
Total Impervious Area 40,612 sf
Target Treatment Percentage 75%
Minimum Area to be Treated by LID measures 30,459 sf
PLD Basin
Basin Size 1,400 sf
Total PLD Treatment Area 33,106 sf
Landscape Buffer
Landscape Buffer Area 540 sf
Run-on area for Landscape Buffer 284 sf
Overall Run-on Ratio for Rain Garden (50:1 Max) 0.5 :1
Total Treatment Area 33,390 sf
Percent Total Project Area Treated 82.2%
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
VEHICLE TRACKING CONTROL PAD SHALL BE LOCATED AT EVERY ACCESS POINT TO THE CONSTRUCTION SITE.
A SIGN SHALL BE PLACED NEXT TO THE VEHICLE TRACKING CONTROL PAD TO DESIGNATE THE LOCATION AS THE CONSTRUCTION ENTRANCE/EXIT.
VEHICLE TRACKING CONTROL PADS SHALL CONSIST OF HARD, DENSE, DURABLE STONE, ANGULAR IN SHAPE AND RESISTANT TO WEATHERING. ROUNDED STONE (i.e. RIVER ROCK
AND COBBLES) SHALL NOT BE USED. THE STONES SHALL BE A MINIMUM OF 3" AND A MAXIMUM OF 6" DIAMETER. THE STONES SHALL HAVE A SPECIFIC GRAVITY OF AT LEAST 2.6.
CONTROL OF GRADATION WILL BE BY VISUAL INSPECTION.
ANY CRACKED OR DAMAGED CURB AND GUTTER AND SIDEWALK SHALL BE REPLACED BY CONTRACTOR.
INSTALLATION NOTES:
1.
2.
3.
4.
CONTRACTOR SHALL INSPECT VEHICLE TRACKING CONTROL PAD DAILY. ROCK SURFACE SHALL BE CLEAN AND LOOSE ENOUGH TO RUT SLIGHTLY UNDER WHEEL LOADS AND CAUSE
LOOSE ROCK TO DISLODGE MUD FROM TIRES. WHEN ROCK BECOMES COMPACTED OR FILLED WITH SEDIMENT SO THAT THE EFFECTIVENESS OF THE PAD IS DIMINISHED, CONTRACTOR
SHALL RIP, TURN OVER, OR OTHERWISE LOOSEN ROCK, PLACE ADDITIONAL NEW ROCK, OR REPLACE WITH NEW ROCK AS NECESSARY TO RESTORE EFFECTIVENESS.
SEDIMENT AND OTHER MATERIAL SPILLED, DROPPED OR TRACKED ONTO PAVED SURFACES SHALL BE REMOVED IMMEDIATELY OR BY THE END OF EACH WORKING DAY.
VEHICLE TRACKING CONTROL PAD SHALL BE REMOVED AT THE END OF CONSTRUCTION. THE AREA SHOULD BE TOPSOILED, SEEDED, CRIMPED, AND MULCHED OR OTHERWISE
STABILIZED.
MAINTENANCE NOTES:
1.
2.
3.
3" - 6" ROCK
CONSTRUCTION FENCE, TYP., TO
DISCOURAGE
VEHICLE ACCESS EXCEPT AT VTC
SIGN "CONSTRUCTION ENTRANCE"
\A1;R=5'
PAVED SURFACE
\A1;20' MIN.
A
SECTION A
NO MATERIALS INCLUDING 2x4'S, PIPES, DIRT, GRAVEL OR ASPHALT, SHALL BE PLACED IN GUTTER TO FACILITATE MOUNTING CURB; HOWEVER, CURB MAY BE CUT DOWN TO A HEIGHT OF 2" OR HIGHER FOR EASIER
ACCESS AND REPLACED AT PROJECT COMPLETION. OTHER ACCESS DEVICES MAY BE USED AS ACCEPTED BY THE CITY. 3" - 6" ROCK
CURB CUT
50' MIN.
2" MIN. 6" MIN.
6" MIN.
ALTHOUGH NOT NORMALLY USED, THE CITY RESERVES THE RIGHT TO REQUIRE VEHICLE TRACKING CONTROL WITH A TEMPORARY CATTLE GUARD
AND/OR WHEEL WASH FACILITIES AT SITES WHERE TRACKING ONTO PAVED AREAS BECOMES A SIGNIFICANT PROBLEM AS DETERMINED BY THE CITY
INSPECTOR.
IF VEHICLE TRACKING CONTROL WITH WHEEL WASH FACILITIES ARE REQUIRED, ALL WHEELS ON EVERY VEHICLE LEAVING THE SITE SHALL BE
CLEANED OF MUD USING A PRESSURE-WASHER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A WATER SOURCE AND CONSTRUCTING
A WASHWATER SEDIMENT TRAP.
5.
6.
IF VEHICLE WHEEL WASH FACILITIES ARE REQUIRED, CONTRACTOR SHALL INSPECT VEHICLE TRACKING CONTROL AND WHEEL WASH FACILITIES DAILY.
ACCUMULATED SEDIMENTS SHALL BE REMOVED FROM THE PAD SURFACE.
ACCUMULATED SEDIMENT IN THE WASHWATER/SEDIMENT TRAP SHALL BE REMOVED WHEN THE SEDIMENT REACHES AN AVERAGE DEPTH OF 12-INCHES.
4.
5.
VTC
0" ON BEDROCK
OR HARD SURFACE,
2" IN SOIL
ROCK SOCK SECTION ROCK SOCK PLAN
4" TO 6" MAX AT CURBS,
OTHERWISE 6"-10" DEPENDING
ON EXPECTED SEDIMENT LOADS
ROCK SOCK JOINTING
\A1;12"
\A1;12"
{ROCK SOCK INSTALLATION NOTES
}1.SEE PLAN VIEW FOR:
- LOCATION (S) OF ROCK SOCKS.
2.CRUSHED ROCK SHALL BE 1{}" (MINUS) IN SIZE WITH A FRACTURED FACE (ALL SIDES) AND SHALL COMPLY
WITH GRADATION SHOWN ON THIS SHEET (1{}" MINUS).
3.WIRE MESH SHALL BE FABRICATED OF 10 GAGE POULTRY MESH, OR EQUIVALENT, WITH A MAXIMUM
OPENING OF {}", RECOMMENDED MINIMUM ROLL WIDTH OF 48".
4.WIRE MESH SHALL BE SECURED USING "HOG RINGS" OR WIRE TIES AT 6" CENTERS ALONG ALL JOINTS
AND AT 2" CENTERS ON ENDS OF SOCKS.
5.SOME MUNICIPALITIES MAY ALLOW THE USE OF FILTER FABRIC AS AN ALTERNATIVE TO WIRE MESH FOR
THE ROCK ENCLOSURE.
GRADATION TABLE
SIEVE SIZE
MASS PERCENT
PASSING SQUARE
MESH SIEVES
NO. 4
2" 100
1-1/2" 90-100
1" 20-55
3/4" 0-15
3/8" 0-5
MATCHES SPECIFICATIONS FOR NO. 4 COARSE AGGREGATE FOR
CONCRETE PER AASHTO M43. ALL ROCK SHALL BE FRACTURED FACE,
ALL SIDES
WIRE ENCLOSED 1 1/2"
WASHED ROCK
CURB AND GUTTER
TUBULAR
MARKER
\A1;2'
RS
NOT TO SCALE
001
C701
CONCRETE WASHOUT AREA
NOT TO SCALE
002
C701
ROCK SOCK
NOT TO SCALE
003
C701
VEHICLE TRACKING BAG
NOT TO SCALE
004
C701
CONSTRUCTION FENCE w/ ROCK SOCKS
TEMPORARY
CHAIN-LINK FENCE
ROCK SOCK
TEMPORARY
CHAIN-LINK FENCE
ROCK SOCK
SIDE VIEW
CF
1.CONCRETE WASHOUT AREA SHALL BE INSTALLED PRIOR TO ANY CONCRETE PLACEMENT ON SITE.
2.VEHICLE TRACKING CONTROL IS REQUIRED IF ACCESS TO CONCRETE WASHOUT AREA IS OFF PAVEMENT.
3.SIGNS SHALL BE PLACED AT THE CONSTRUCTION ENTRANCE, AT THE WASHOUT AREA, AND ELSEWHERE AS NECESSARY TO CLEARLY
INDICATE THE LOCATION OF THE CONCRETE WASHOUT AREA TO OPERATORS OF CONCRETE TRUCKS AND PUMP RIGS.
4.THE CONCRETE WASHOUT AREA SHALL BE REPAIRED AND ENLARGED OR CLEANED OUT AS NECESSARY TO MAINTAIN CAPACITY FOR
WASTED CONCRETE.
5.THE CONCRETE WASHOUT SHOULD BE EMPTIED WHEN HALF OF TOTAL HOLDING CAPACITY HAS BEEN REACHED.
6.AT THE END OF CONSTRUCTION, ALL CONCRETE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF AT AN ACCEPTED WASTE SITE.
7.WHEN THE CONCRETE WASHOUT AREA IS REMOVED, THE DISTURBED AREA SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED
IN A MANNER ACCEPTED BY THE CITY.
8.LOCATION OF CONCRETE WASHOUT AREA ON SHEET EC1 IS CONCEPTUAL ONLY. FINAL LOCATION TO BE DETERMINED IN THE FIELD AT
CONTRACTOR'S DISCRETION.
{\LNOTES:}
3H:1V OR FLATTER
SIDE SLOPES
\A1;12" MIN
8'x 8' MIN
OR AS REQUIRED TO
CONTAIN WASTE CONCRETE
\A1;12" \A1;2'-0" MIN.
COMPACTED EMBANKMENT
MATERIAL, TYP.
BERM AROUND PERIMETER
GROUND SURFACE
SIGN TO INDICATE THE
LOCATION OF THE
CONCRETE WASHOUT AREA
CWA
* IMPERMEABLE LINER MAY BE NEEDED IF GROUND WATER IS ENCOUNTERED.
COLLAR & CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 5'
WALK w/ PAN
PROPOSED 1'
SIDEWALK CHASE PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
9' UTILITY EASEMENT
THE LOFTS AT CAMPUS WEST
TOWN SQUARE
CONDOMINIUMS
CITY PARK CONDOMINIUMS
(BOOK 1291, PAGE 862)
THE DISTRICT AT CAMPUS WEST
(REC. NO. 20130032356)
PROPOSED
STORM DRAIN
DETENTION VAULT
CF CF CF CF CF CF CF CF CF CF CF CF CF CF
CF CF CF CF CF
CF CF CF CF CF
CF CF CF CF CF CF CF CF CF CF
RS
VTC
CWA
CF
RS
RS RS
RS RS
CF
CF
CF CF
CF
CF CF
CF CF
RS
RS
CF
CF CF CF
CF
CF CF CF CF CF CF CF CF CF CF CF CF CF CF
PROVIDE APPROVED ACCESS
LOCATION THROUGH CONSTRUCTION
FENCE PER PFA REQUIREMENTS.
IP
INLET PROTECTION
NEAREST DOWNSTREAM INLET
RS
RS RS
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
C700
EROSION CONTROL PLAN
A. Reese
B. Ruch
1"=20'
No. Revisions:
By: Date:
REVIEWED BY:
N. Haws
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
Feb. 22, 2017
PROJECT:
1252-001
Sheet
of 17 Sheets
WEST PLUM HOUSING
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
02/22/17
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
NORTH
( IN FEET )
1 inch = ft.
20 0 20 Feet
20
40 60
BENCHMARK
1. IT SHOULD BE NOTED THAT ANY EROSION CONTROL PLAN SERVES ONLY
AS A GUIDELINE TO THE CONTRACTOR. STAGING AND/OR PHASING OF
BEST MANAGEMENT PRACTICES (BMPs) IS EXPECTED. ADDITIONAL AND/OR
DIFFERENT BMPs FROM THOSE ORIGINALLY DEPICTED MAY BE NECESSARY
DURING CONSTRUCTION DUE TO CHANGING SITE CONDITIONS OR AS
REQUIRED BY LOCAL AUTHORITIES.
2. THIS EROSION CONTROL PLAN IS SCHEMATIC IN NATURE. AS SUCH,
GRAPHICAL SYMBOLS MAY NOT BE TO SCALE, NOR ARE THEY
NECESSARILY SHOWN IN THEIR EXACT LOCATION.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITTING (CITY,
STATE DISCHARGE PERMIT, ETC.) AND COMPLIANCE WITH GOVERNING
AUTHORITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR (OR
PERMIT HOLDER) TO ENSURE EROSION CONTROL MEASURES ARE
PROPERLY MAINTAINED AND FOLLOWED.
4. CONTRACTOR SHALL IMPLEMENT THE APPROPRIATE EROSION CONTROL
MEASURES ACCORDING THE THE CONSTRUCTION SEQUENCING AND LEVEL
OF SITE STABILIZATION.
5. CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR
ALL STORM DRAINS, SWALES, PONDS AND RAIN GARDENS UNTIL SITE IS
FULLY STABILIZED.
6. CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR
DOWNSPOUT CONNECTIONS, TO THE STORM DRAIN SYSTEM, UNTIL
CONNECTION IS ESTABLISHED WITH DOWNSPOUT.
7. INLET PROTECTION SHALL BE ADAPTED, AS NECESSARY, TO THE
SURROUNDING SURFACE TYPE AND CONDITION (i.e., STAKE-DRIVEN
WATTLES FOR BARE SOIL, GRAVEL SOCKS FOR PAVEMENT, ETC.)
8. CONTRACTOR IS RESPONSIBLE FOR STABILIZING ALL SLOPES,
PARTICULARLY THOSE STEEPER THAN 6:1. CRIMP MULCHING, HYDRO
MULCHING, EROSION MATS, TEMPORARY IRRIGATION, AND ADDITIONAL
WATTLES OR SILT FENCING MAY BE NECESSARY TO ESTABLISH
VEGETATIVE COVER AND STABILIZE THE SLOPE.
9. CONTRACTOR IS RESPONSIBLE FOR PREVENTING SEDIMENT FROM
UNSTABILIZED LANDSCAPE AREAS FROM MIGRATING ONTO AND ENTERING
THE PERMEABLE PAVER SYSTEMS UNTIL UPGRADIENT TRIBUTARY AREAS
ARE FULLY STABILIZED.
10. ADDITIONAL WATTLES, SILT FENCE, OR OTHER MEASURES, MAY BE
NECESSARY TO ENSURE THAT EACH BUILDING PAD IS STABILIZED
THROUGHOUT CONSTRUCTION. WATTLES SHALL BE PROVIDED AROUND
BUILDING PAD SIDES TO ENSURE AT NO TIME SHALL SEDIMENT BE
ALLOWED TO CROSS THE PUBLIC SIDEWALKS.
11. CONTRACTOR SHALL IMPLEMENT APPROPRIATE PERIMETER PROTECTION
FOR AREAS DIRECTING DRAINAGE OFFSITE. PERIMETER PROTECTION
SHALL BE ADAPTED, AS NECESSARY, TO THE SURROUNDING SURFACE
TYPE AND CONDITION (i.e., STAKE-DRIVEN SEDIMENT CONTROL LOGS OR
SILT FENCE FOR BARE SOIL, GRAVEL SOCKS FOR PAVEMENT, ETC.)
12. FUELING FACILITIES SHALL BE LOCATED AT LEAST ONE HUNDRED (100)
FEET FROM NATURAL BODY OF WATER, WETLAND, NATURAL DRAINAGE
WAY OR MANMADE DRAINAGE WAY. THE FUEL TANKS AND FUELING AREA
MUST BE SET IN A CONTAINMENT AREA THAT WILL NOT ALLOW A FUEL
SPILL TO DIRECTLY FLOW, SEEP, RUN OFF, OR BE WASHED INTO A BODY OF
WATER, WETLAND OR DRAINAGE WAY.
13. CONSTRUCTION WASTE STORAGE (DUMPSTERS) AND PORTABLE
SANITATION UNITS (CONSTRUCTION TOILETS) SHALL BE LOCATED AT
LEAST FIFTY (50) FEET FROM ANY STORMWATER INLET, WETLAND, OR
DRAINAGE WAY. SAID FACILITIES MUST BE SET IN A CONTAINMENT AREA
THAT WILL NOT ALLOW POLLUTANTS TO DIRECTLY FLOW, SEEP, RUN OFF,
OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE WAY.
DUMPSTERS SHALL BE LOCATED ON FLAT, STABLE GROUND, AND
CONSTRUCTION TOILETS SHALL BE STAKED DOWN.
14. THE CONTRACTOR AND ALL SUBCONTRACTORS WILL COOPERATE WITH
THE CITY'S CONSTRUCTION INSPECTORS BY CEASING OPERATIONS WHEN
WINDS ARE OF SUFFICIENT VELOCITY TO CREATE BLOWING DUST WHICH,
IN THE INSPECTOR'S OPINION, IS HAZARDOUS TO THE PUBLIC HEALTH AND
WELFARE.
15. WHERE SEASONAL CONSTRAINTS (E.G., DURING SUMMER AND WINTER
MONTHS) INHIBIT PERMANENT SEEDING OPERATIONS, DISTURBED AREAS
WILL BE TREATED WITH MULCH AND MULCH TACKIFIER OR OTHER
MATERIALS APPROVED BY EROSION CONTROL STAFF TO PREVENT
EROSION.
16. CONTRACTOR SHALL EXERCISE CAUTION TO PROTECT RAIN GARDENS AND
MODIFIED RAIN GARDEN FROM SEDIMENTATION. THIS INCLUDES
EDUCATING SUBCONTRACTORS ON-SITE.
17. SEE LANDSCAPE PLANS FOR ADDITIONAL INFORMATION ON PLANTING,
REVEGETATION, HARDSCAPE AND OTHER PERMANENT SITE STABILIZATION
METHODS.
18. DIRT AND DEBRIS FROM CONSTRUCTION ACTIVITIES TRACKED ON CITY
STREETS SHALL BE KEPT TO A MINIMUM AND CLEANED NIGHTLY OR AT THE
SUGGESTION OF THE CITY'S EROSION CONTROL INSPECTOR.
19. CONTRACTOR SHALL KEEP CONSTRUCTION VEHICLES ENTERING AND
EXITING SITE TO A MINIMUM.
EROSION CONTROL NOTES:
NOTE:
ALL BMPS SHOWN ON THIS PLAN ARE GRAPHIC
REPRESENTATIONS ONLY. FINAL DETERMINATION OF SIZE
AND LOCATION SHALL BE DETERMINED BY THE CONTRACTOR
AND DOCUMENTED ON THE DYNAMIC SITE PLAN.
1. CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BY CRIMP
MULCHING OR SIMILAR METHODS.
2. TOTAL DISTURBED AREA = 1.38 ACRES
3. SWMP ADMINISTRATOR:
Contact ________________________________
Company ________________________________
Address ________________________________
Phone________________________________
4. CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE WASHOUT
AREA IF ACCESS IS OFF PAVEMENT.
5. REFER TO THE FINAL DRAINAGE REPORT FOR WEST PLUM HOUSING, DATED
FEBRUARY 22, 2017, BY NORTHERN ENGINEERING, FOR ADDITIONAL INFORMATION.
GENERAL NOTES:
LEGEND:
4953
PROPOSED CONTOUR
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED INLET
VEHICLE TRACKING CONTROL PAD
CONSTRUCTION FENCE w/ ROCK SOCK CF
CONCRETE WASHOUT
ROCK SOCK
TABLE OF CONSTRUCTION SEQUENCE AND BMP APPLICATION
Project: West Plum Housing
CONSTRUCTION PHASE MOBILIZATION DEMOLITION GRADING
BEST MANAGEMENT PRACTICES (BMPS)
Structural "Installation"
Flow Barriers (Bales, Wattles, etc.) (RS)
UTILITIES
INSTALLATION
FLAT WORK
INSTALLATION
VERTICAL
INSTALLATION LANDSCAPE DEMOBILIZATION
Concrete Washout Area (CWA)
* All Temporary BMPs to be Removed once Construction is Complete
Vehicle Tracking Pad * (VTC)
CWA
RS
VTC
CF
PROJECT DATUM: NAVD88
CITY OF FORT COLLINS BENCHMARK 19-97
AT THE SOUTHEAST CORNER OF WEST ELIZABETH AND SHIELDS ST., ON A CONCRETE
TRAFFIC SIGNAL BASE.
ELEV.= 5025.74
CITY OF FORT COLLINS BENCHMARK 3-08
SOUTHWEST CORNER OF MULBERRY ST. AND SHIELDS ST. ON A CONCRETE TRAFFIC
SIGNAL BASE.
ELEV.= 5030.29
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING
DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING
EQUATION SHOULD BE USED:
NGVD29 UNADJUSTED = NAVD88 - 3.17'
BASIS OF BEARINGS
THE BASIS OF BEARINGS IS THE SOUTH LINE OF THE NORTHEAST QUARTER OF SECTION
15, AS BEARING SOUTH 89°04'20" EAST.
Construction Fence (CF)
INLET PROTECTION IP
NOT TO SCALE
401
C603
STANDARD DRIVEWAY APPROACH
NOT TO SCALE
402
C603
DRAINAGE UNDER SIDEWALK
NOT TO SCALE
403
C603
NOT TO SCALE
404
C603
NOT TO SCALE
405
C603
NOT TO SCALE
406
C603
TRUNCATED DOME WARNING FOR ACCESS RAMPS
6"
2"R.
2"
6" 6"
12"
1 1/2"R.
2'-6"
6"
4 1/2"
30"
9"
R 0.5"
4.5"
18"
3.63"
21.75"
R 0.13"
7"
2"
3.75"
12"
ROLL-OVER
VERTICAL
(LOVELAND)
Gutter edge may be
tapered or battered.
(Typical for all Curb &
& Gutter Types)
DATE: 03/01/02
CURB AND GUTTER
URBAN AREA
STREET STANDARDS
LARIMER COUNTY
CONSTRUCTION DRAWINGS REVISION NO: 1 701
DRAWING
NOTES:
1. 6' wide pan for residential streets.
2. All intersections to have access ramps.
3. Standard Curb and Gutter Section, See Standard Drawing 701
4. 0" Curb Height, See Section A-A
5. All of these pedestrian improvements shall
be in ROW or a pedestrian or public access easement.
6. Detectable Warning to extend the full width of the ramp and be 2'-0"
in the direction of travel. Maximum slope in the direction of travel shall be no
more than 5.0 percent (1:20). Material to be approved by local engineer
7. T = 6" for residential and 8" for commercial.
8. Distance from back of curb to the beginning of Detectable
Warning cannot be greater than 5'-0"
TYPE III
DETACHED WALK
N.T.S.
SECTIONS A-A
CLASSIFICATION APPROACH
TYPE
Single Family 12' 24'
Commercial I, II, III, or IV
Multi Family
24' 36'
24' 36'
MINIMUM
WIDTH WIDTH
MAXIMUM
Industrial 24' 36'
I, II, III, or IV
I or II
RESIDENTIAL:
*
*
* *
*
DRIVEWAY WIDTHS
LARIMER COUNTY DRAWINGS CONSTRUCTION REVISION NO: 1 707.DRAWING 1
STREET STANDARDS
URBAN AREA DATE: 02/17/15
STANDARD DRIVEWAY APPROACH (HIGH VOLUME DRIVE TYPE III)
High volume driveways (Type III or IV) allowed for 350 or
greater trip ends/day.
* 30' maximum for 3 car garages.
* *No single opening shall exceed 36'. Wider driveways shall
be divided w/a median not less than 6' wide.
1/4" per ft.
1" per ft.
1:50 Slope
T
Walk
1:50 1:12
(max.)
Gutter
Parkway
Sidewalk
Detached 1:12
A
A
(max)
2'
Flare
See Note 4
See Note 3
If Concrete Driveway
Expansion Joint
NOT TO SCALE
See Note 6
1/4" per ft. 1" per ft.
1:12 (max.)
1" per ft.
Driveway
FL
See Note 8
I, II, III, or IV
Sidewalk
Detached
or equivalent. (typical both sides)
With curb walk, cover plate extends
from property line to top of walk face.
6" VERTICAL CURB, GUTTER, AND SIDEWALK
SECTION A-A (2 VIEWS)
COMBINATION CURB, GUTTER, AND SIDEWALK
center, Nelson Standard Anchor
3" #4 Bar Welded at 12" on
L = 1 1/4" x 1 1/4" x 1/4"
5/8" Rolled Steel Tread Plate
SECTION C-C
1.0' (minimum)
approved by the Engineer.
Right of Way line to flow line unless
2. Chase and cover plate run from
1. Length of steel plate varies.
Notes:
Dimension Variable
(diamond pattern)
5/8" Rolled Steel Tread Plate
4'-0" or as Directed
Retaining Screws at
Top of Curb
C B
A
C B
PLAN VIEW
A
Street
10 3/8" SECTION B-B
6"
1 1/4"
STANDARD DETAILS FOR DRAINAGE UNDER SIDEWALK
STREET STANDARDS
LARIMER COUNTY
URBAN AREA CONSTRUCTION DRAWINGS DATE: REVISION 04/NO: 01/07 1 709
DRAWING
Attached
Ft. Collins only
Detached Sidewalk
finish 12" on center
Screw Brass or Electro-galv.
1/2" x 1" Flat Head Mach.
threaded to receive screw.
Angle iron to be drilled and
screw to extend into the
Concrete to be drilled to allow
Lip of Gutter
concrete
(typical both sides).
(typical both sides)
F L
Sidewalk
X (Varies, See Plans
Xmax=2.0')
d (Varies,
See Plans)
ATTACHED SIDEWALK DETAIL
Slope sidewalk to curb 1/4" per foot.
NOTE: Construct sidewalk with joints at 10' intervals
R 1/8"
WEAKENED PLANE JOINT EXPANSION JOINT
R1/4"
and aligned with scoring on curb.
INSTALL IN LOCATIONS SPECIFIED
IN CHAPTER 22
1/2"
1/4"
1/4 SLAB THICKNESS
1/4"
1/2" Expansion
Joint material
DETACHED SIDEWALK DETAIL
Variable
Landscaping
Slope sidewalk to curb 1/4" per foot.
2' min.
Slope: Minumum
1
4"/ft
Maximum 3"/ft
CONSTRUCTION
SIDEWALK DETAIL
LARIMER COUNTY
STREET URBAN STANDARDS AREA DRAWINGS 1602
DRAWING
REVISION DATE: 04/NO: 01/07 2
02/17/15
STANDARD SIDEWALK
URBAN AREA
STREET STANDARDS
LARIMER COUNTY
CONSTRUCTION DRAWINGS REVISION NO: 1601
DRAWING
DATE:
4
Driveway
Driveway Sidewalk
SECTION A-A
Detached Sidewalk
Attached Sidewalk
Detached Attached
All Sidewalk Thickness Shall Be 6" minimum.
Sidewalk
NOTE:
1. Sidewalk grade shall remain consistent across driveway
2. For driveway design requirements, see CONST. DWG. Series 706 & 707
3. This detail applies to Residential & Commercial driveways.
6"
2'-0" 6'-0"
T.C.
F.L.
Lip
1/2" Expansion
Joint Material
1/2" Expansion
Joint Material
8" Commercial
6" Residential
A
A
Sidewalk
Min.
NOT TO SCALE
02/17/15
RESIDENTIAL LOCAL STREET ACCESS RAMPS
URBAN AREA
STREET STANDARDS
LARIMER COUNTY
CONSTRUCTION DRAWINGS REVISION NO: 3 1606a
DRAWING
DATE:
FORT COLLINS ONLY
Notes:
1. Set ramp slopes using the center of the
ramp.
2. Truncated dome warning panel: Install
panels along with the concrete pour for the
ramp. Specifications for the panel material
will be provided upon request.
3. Each ramp shall align perpendicular to the
street in which the ramp is provided to
cross.
4. Refer to standard drawing 1606 in the
Laimer County urban area street standards
for other necessary criteria needed to
construct these ramps that is not specified
on this drawing.
5. Construct the ramps and walk so the corner
area all drains to the street.
6. If curb and gutter are poured monolithic with
ramp, place dome edge at back of curb as
shown. If not poured monolithic, place
dome edge 6" from back of curb.
PLAN VIEW
NTS
Ramp
Flare
Gutter
Ramp
Ramp
Flare
Curb
Curb
Conc. Flare
Panels Panels
Truncated dome
panels:
1-2'x2.5'
1-2'x2'
Truncated Dome Warning
Detection Plan Locations
LEGEND:
BOC- Back of
curb ⅊ Property
Line
PT - Point of Tangency
Flow line
Section A-A
NTS
4'-6"
2'-6" 2'-0"
2'-0"
t
Varies
Varies
4.5'
6.0'
.5'
1.5'
4.5'
1.5 '
12.0'
12.0'
4.5'
.5'
4.5' 6.0'
Landscaped
Area
PT Curb
A
A
6" Curb
(TYP)
0" Curb
Full height
curb
Truncated dome
warning detection
⅊
PT of walk
R15.0'
⅊
⅊ & BOW
5'-6" BOC to walk w/ vertical curb
5'-7" BOC to walk w/ drive over curb
Conc. Sidewalk
Area to be landscaped
Conc. walk
Gutter
or
Apron
Truncate Dome
Warning Panel
1:12 Max slope
1:20
Slope
PT of
curb
return
6"
Conc. Flare
6" Curb
(TYP)
NOT TO SCALE
See note 6
02/17/15
TRUNCATED DOME WARNING FOR ACCESS RAMPS
URBAN AREA
STREET STANDARDS
LARIMER COUNTY
CONSTRUCTION DRAWINGS REVISION NO: 3 1607
DRAWING
DATE:
Curb
Flare
Varies
Curb
Flare
Ramp
Curb
Curb
Flare
Ramp
Varies
Panels
Panels
6"
Ramp
Width:
4.5'
5.0'
6.0'
7.0'
8.0'
Note:
Truncated dome panels are
available in 2'x2' squares
and 2'x2.5' rectangles.
Combine the widths to fit
the ramp. Panels may be
cut to no less than a 2'x1.5'
size.
Panel Width
Combinations:
2'+2.5'
2.5'+2.5'
2'+2'+2'
2.5'+2'+2.5'
2'+2'+2'+2'
Notes:
1. Truncated dome warning panel:
Install panels along with the
concrete pour for the ramp.
Specifications for the panel and
installation instructions will be
provided upon request.
2. This drawing shows vertical curb.
For Drive Over Curb the warning
detection location shall be placed in
the same position 6" back from the
back of curb.
3. If curb and gutter are poured
monolithic with ramp, place dome
edge at back of curb as shown. If
not poured monolithic, place dome
edge 6" from back of curb.
Case 1-Directional Ramps
Case 2-Non-Directional Ramps
Varies
Panels
Ramp
Panels
Flare
Curb
Case 3-Mid-Block Ramps
6"
Panels Panels
Flare
6"
Flare
Varies
FORT COLLINS ONLY
Aligned with
Pedestrian flow
Gutter
or
Apron
℄Center line of ramp
BOC-Back of Curb
FOC -Face of Curb
-Flow line
Varies
2'-0"
2'-0"
A
A
FOC or ℄
2'-0"
BOC
BOC
1:20 1:12 max slope
slope
Panels embedded in the
concrete ramps
Section A-A (Center line of ramp)
NTS
Flow line Curb
and Gutter
BOC
NOT TO SCALE
See Note 3
STANDARD SIDEWALK
SIDEWALK DETAIL RESIDENTIAL LOCAL STREET ACCESS RAMPS
6 IN.
SEE
DETAIL 'A'
BOLT LAYOUT PER
MANUFACTURER
B B
A
A
12" WIDE COVER
(SEE DETAIL ABOVE)
FRAME AND
ANCHORING BY
MANUFACTURER
12" WIDE COVER
(COORDINATE w/ OWNER
AND LANDSCAPE ARCH.)
1
8 IN. PER FT. SLOPE
NOTES:
1. CONFIRM FRAME AND GRATE DIMENSIONS WITH
MANUFACTURER PRIOR TO POURING CONCRETE CHASE.
2. DEPTH OF CHASE VARIES BY 1
2 IN. TO PROVIDE
1
8 IN. PER FOOT
SLOPE ALONG CHANNEL BOTTOM.
SIDEWALK
ISOMETRIC VIEW
SECTION A-A
DETAIL 'A'
SECTION B-B
4'-6"
6"
3'-0"
SEE NOTE 1
6"
2
1
2
1
DECORATIVE
IRON GRATE VARIES,
6" TYP.
FRAME AND MOUNTING
HARDWARE BY MANUFACTURER
(SEE DETAIL A)
COBBLE SWALE
1'
CHASE
1'
CHASE
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
NOT TO SCALE
407
C603
TYPICAL PASS-THROUGH SIDEWALK CHASE
NOT TO SCALE
301
C602
CURB, GUTTER AND SIDEWALK
NOT TO SCALE
302
C602
METAL SIDEWALK CULVERT FOR VERT. CURB & GUTTER
AND DETACHED SIDEWALK-OUFALL TO CURB
NOT TO SCALE
304
C602
CLASS B BEDDING
LOWER LIMIT OF
UNIFORM GRADED
CLASS A BEDDING
LOWER LIMIT OF
LOWER LIMIT OF
MATERIAL
TRENCH WIDTHS SHALL BE AS SPECIFIED ON PLANS.
REFER TO THE STORM SRAINAGE CONSTRUCTION STANDARDS,
SECTION 6, "BEDDING MATERIALS" FOR GRADATIONS.
SUBDRAIN DETAIL
TRENCH WIDTH AS SPECIFIED
TRENCH WIDTH AS SPECIFIED
ROCK EXCAVATION
TRENCH WIDTH AS SPECIFIED
GRANULAR MATERIAL
UNSTABLE SUBGRADE
TRENCH WIDTH AS SPECIFIED
ROCK
1 1/2 IN.
COMPACTED
GRANULAR OR
TRENCH WALL
SLOPE
COMPACTED
MATERIAL GRANULAR
%%UNOTES:
2.
1.
6 IN. MIN.
4 IN. MIN.
\A1;1/8 PIPE O.D.
OR 4 IN. MIN.
SLOTTED PIPE
PERFORATED OR
GRAVEL
FILTER
BACKFILL
COMPACTED DENSELY
TRENCH WIDTH AS SPECIFIED
CLASS C BEDDING
TRENCH WIDTH AS SPECIFIED
\A1;1/4 PIPE O.D.
SLOPE
MATERIAL
COMPACTED
TRENCH DENSELY WALL
\A1;PIPE O.D. + 8 IN.
\A1;1/4 PIPE O.D.
MATERIAL
COMPACTED
DENSELY
SLOPE
TRENCH WALL
MATERIAL
\A1;PIPE O.D.
OR 6 IN. MIN.
\A1;1/8 PIPE O.D.
3000 CONCRETE P.S.I.
TRENCH WALL
LOWER LIMIT OF
UNIFORMLY
SELECTED GRADED
SLOPE
GRADED COMPACTED ROCK OR
MATERIAL
GRANULAR
COMPACTED
\A1;PIPE O.D.
TRENCH WALL
LOWER LIMIT OF
SLOPE
COMPACTED
DENSELY
FILTER
6 IN. MIN.
\A1;PIPE O.D.
\OR A1;4 1/IN. 8 PIPE MIN. O.D.
\A1;PIPE O.D.
BROKEN LARGE (IF CONCRETE, REQUIRED) STONES, ETC.
MATERIAL
LOWER LIMIT OF
TRENCH WALL
SLOPE
APPROVED: DATE: DETAIL
DRAWN BY:
FORT COLLINS CONSTRUCTION STORMWATER DETAILS
FORT COLLINS, CO.
UTILITIES
CITY OF
(970) 221-6700
STORMWATER BEDDING REQUIREMENTS
1/12/00 D-1
SKC
APPROVED: DATE: DETAIL
DRAWN BY:
FORT COLLINS CONSTRUCTION STORMWATER DETAILS
FORT COLLINS, CO.
UTILITIES
CITY OF
(970) 221-6700
CURB, GUTTER AND SIDEWALK DETAILS
11/13/00 D-6
NBJ
DRIVE-OVER CURB, GUTTER AND SIDEWALK
VERTICAL 6 IN. CURB, GUTTER AND SIDEWALK
DUMMY JOINT
FOR WALKS
COMBINATION CURB, GUTTER AND SIDEWALK
"HOLLYWOOD"
(OBSOLETE - FOR REPLACEMENT ONLY)
EDGED
1/8 IN. R.
1/8 IN.
3/4 IN. MIN.
SURFACE
4 FT. MIN.
.30 FT.
6 IN.
.11 FT.
.09 FT.
4.43 FT.
1.18 FT. .58 FT. 2.67 FT.
6 IN.
12 IN.
6 IN.
2 FT 6 IN.
2 IN.
6 IN.
1 1/2 IN.
4 1/2 IN.
1 1/2 IN. R
2 IN. R
WHERE WALK ADJOINS A CURB, IT SHALL BE
CONSTRUCTED 1/4 INCH ABOVE THE CURB.
SLOPE SIDEWALK TO CURB -
1/4 IN. TO 1/2 IN. PER FT.
6 IN.
1 3/8 IN. (.11 FT.)
3 3/8 IN. (.28 FT.)
18 IN.
(1.5 FT.) (1.5 FT.)
18 IN.
(1.17 FT.)
LIMITS OF C & G
(1.42 FT.) (3.75 FT.)
3 FT. 9 IN.
FLOW
LINE
(1.33 FT)
16 IN. R
(1.33 FT.)
16 IN. R
6 IN.
1 1/2 IN.
APPROVED: DATE: DETAIL
DRAWN BY:
STORMWATER
CONSTRUCTION DETAILS
FORT COLLINS
FORT COLLINS, CO.
UTILITIES
CITY OF
(970) 221-6700 D. MOGEN
7/30/2013 D-10B
METAL SIDEWALK CULVERT FOR VERT. CURB & GUTTER AND DETACHED SIDEWALK - OUTFALL TO CURB
2
1
2
1
\A1;6"
\A1;6"
\A1;VARIES
\A1;\A1;3' 2'
SECTION B-B
DETAIL 1
SECTION A-A
PLAN
SECTION C-C
SLOPE
\A1;VARIES VARIES 0.5% SLOPE \A1;VARIES (MIN.)
\A1;2' DEPRESSED GUTTER
\A1;VARIES
\A1;3'-3" \A1;2' OPENING \A1;3'-3"
\A1;6" (TYP.)
\A1;3" (TYP.)
\A1;3' (TYP.)
SIDEWALK
(TYP.)
\A1;VARIES \A1;VARIES
SLOPE
C C
B B
A
A
\A1;8'-6"
\A1;\A1;6" 2'
CONCRETE SIDEWALK w/ PAN
CAD FILE NAME:
DETAILS (MODIFIED)
DRAWN BY: T. COX
D46.dwg
OUTLET STRUCTURE
DATE DRAWN: 8/15/05
C C
A
A
\A1;Ls \A1;3'-6"
(MIN.) \A1;6"
\A1;Ws
\A1;6"
\A1;6"
\A1;VARIES \A1;VARIES
\A1;6"
\A1;Ws/2 \A1;Ws/2
OUTLET CENTERLINE PIPE OF
SECTION C-C
SECTION A-A
WELL SCREEN
##4@4@12" 12"
#4@18"
#4@12"
\A1;2'-6"
#4L@12"
#4@12"
\A1;6"
Wo
\A1;Wo
INTO CONCRETE SIDES
STEEL CHANNEL FORMED
3/8"x1" FLAT
BAR HOLDING
FRAME
INTERMITTANT WELDS ON TOP AND SIDES
STAINLESS STEEL ANCHOR BOLTS OR
51"x51" GRATING
(3/8" ROUND OR
TWISTED CROSS
BARS AT 3" O.C.,
WELDED TO 1"x3/8"
BEARING BARS AT
2 1/2" O.C.)
3/8" ROUND OR
TWISTED CROSS
BAR
BAR
1"x3/BEARING 8"
PLAN
\A1;3"
CLR.
3"
CLR.
3" CLR.
TO FASTEN GRATE DOWN
\A1;3/8"x6" THREADED BOLT D1
4 OR 3
4. ALL TRASH RACKS SHALL BE MOUNTED USING STAINLESS STEEL HARDWARE AND
PROVIDED WITH HINGED AND LOCKABLE OR BOLTABLE ACCESS PANELS.
5. TRASH RACKS SHALL BE STAINLESS STEEL, ALUMINUM, OR STEEL. STEEL TRASH
RACKS SHALL BE HOT DIP GALVANIZED AND MAY BE HOT POWDER PAINTED
AFTER GALVANIZING.
3 1/2"
x1 1/2"
KEY
OUTLET PIPE
4% 4%
CLR.
3"
BAR
#4 HOOP
PIPE
CONCRETE
METAL OR
F
LAP
12"
#4@12" O.C.
O.C.
#4@12"
CONCRETE SHALL BE CLASS B. MAY BE CAST-IN-PLACE OR PRECAST.
GENERAL NOTES
1.
2.
3. STEPS SHALL BE PROVIDED WHEN VERTICAL DIMENSION EXCEEDS 3'-6"
AND SHALL BE IN ACCORDANCE WITH AASHTO M 199.
HAVE A MINIMUM 2" CLEARANCE.
REINFORCING BARS SHALL BE EPOXY COATED AND DEFORMED, AND SHALL
#4 DIAGONAL
(TYP.)
SECTION B-B
ELEV. B
ELEV. A
ELEV. C
WQ
WATER QUALITY
100-YEAR OUTLET
B
B
ELEV. A (POND INV.)
ELEV. B (WQCU ELEV)
ELEV. C
SPILL ELEV.
WQ
HOLE DIA.
# OF COLUMNS # OF ROWS
SECTION LINE A-A (ARROWS
A A POINT IN DIRECTION SECTION
OPP. OPPOSITE
CLR. CLEARANCE
ABBREVIATIONS
MINIMUM
MAXIMUM
ON CENTER
DIAMETER
TYPICAL
WIDTH OF CONCRETE OPENING
WIDTH OF PLATE
NUMBER
@ AT
#
Wp
Wo
TYP.
DIA.
O.C.
MAX.
LEGEND
WQ WATER QUALITY
D WQ
INV. INVERT
ELEV. ELEVATION
\A1;6"
Ls
Ws
\A1;6"
Ls LENGTH OF STRUCTURE
Ws WIDTH OF STRUCTURE
Wo
(12" MIN.)
STEEL OR EQUAL)
(NOTE 5)
TRASH RACK
(U.S. FILTER STAINLESS
WELL SCREEN NO. 93
TRASH RACK
STEEL OR EQUAL)
(U.S. FILTER STAINLESS
WELL SCREEN NO. 93
EQUAL)
FILTER STAINLESS
NO. 93 (U.S.
WELL SCREEN
STEEL OR
DETAIL
LAST DATE REVISED: 4/7/11 D-46
3/8"x6" THREADED BOLT
TO FASTEN GRATE DOWN
GRATE (TYP. OPP. SIDE)
2 1/4" FROM EDGE OF
TO HOLD HINGE IN PLACE,
3/8"x6" BOLTS 12" O.C.
TO COVER OPENING
(FASTEN WITH 3/8"x6"
TREADED 1/4" METAL BOLTS) PLATE
TO GRATE, WITH
TO GRATE, WITH
(TYP. OPP. SIDE)
GRATE (TYP. OPP. SIDE)
2 1/4" FROM EDGE OF
TO HOLD HINGE IN PLACE,
3/8"x6" BOLTS 12" O.C.
1/4" PLATE, WELDED
1/4" PLATE, WELDED
STORMWATER CONSTRUCTION DETAILS
(970) 221-6700
P.O. BOX 580, FORT COLLINS, CO. 80522
CITY OF FORT COLLINS UTILITIES
EXTERIOR WALL
NOT TO SCALE
306
C602
ORIFICE PLATE
ORIFICE OPENING
(6.25" Ø)
PLATE CENTERED
OVER PIPE OPENING
IN WALL
1
2" Ø HOLES FOR
3
8" Ø EXPANSION BOLTS
EMBEDDING 2" INTO
CONCRETE WALL @
6" O.C. MIN.
5
16" THICK
GALVANIZED
STEEL PLATE D
D+4"
D+4"
ORIFICE INVERT SHALL MATCH
PIPE INVERT
NOT TO SCALE
305
C602
OUTLET STRUCTURE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
NOT TO SCALE
303
C602
CONCRETE COLLAR & CHASE
1' 4'
1"
2.00%
8.33%
6"
5036.13
5037.13
5038.13
N/A
4'
4'
12"
WALK
LANDSCAPED AREA
LANDSCAPED AREA
0.5 (MIN.) %
7'
8" PVC PIPE
SEE PLANS
6" TYP.
30" VERTICAL
CURB & GUTTER
2'
8"
±15"
9.5'
2' CHASE
0.5 (MIN.) %
LANDSCAPED AREA
LANDSCAPED AREA
12"
N/A
N/A
N/A
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
NOT TO SCALE
200
C601
BEDDING REQUIREMENTS
NOT TO SCALE
201
C601
STANDARD MANHOLE
COMPACTED GRANULAR MATERIAL
CONFORMING TO CDDH #67
LOWER LIMIT OF
TRENCH WALL
SLOPING
INITIAL LIFT *
12 IN. MIN.
PIPE O.D.
4 IN. MIN.
TRENCH WIDTH AS SPECIFIED
IN SECTION 02221
COMPACTED GRANULAR MATERIAL
CONFORMING TO CDDH #67
*
DATE REVISED:
SEWER CONSTRUCTION DETAILS APPROVED: DRAWN BY: DETAIL
BEDDING REQUIRMENTS
WW-1
NBJ
4/11/11
ALTERNATE BASE
POURED INVERT
PRECAST MANHOLE BASE
2 IN. MIN.
SLOPE
1 IN. MIN.
8 IN. MIN.
6 IN.
15 IN. OR LESS 48 IN.
18 IN. TO 30 IN. 60 IN.
OVER 30 INCHES 72 IN.
MIN. MANHOLE
MINIMUM INSIDE DIAMETER OF
DIAMETER
MANHOLE SHALL BE AS FOLLOWS:
PIPE SIZE
5 FT. MIN. DEPTH
CONCRETE ADJUSTMENT SHIMS
GROUTED INSIDE
ASTM C-478 ECCENTRIC CONE
PRE-FORMED PLASTIC GASKET
ASTM C-478 MANHOLE SECTIONS
GROUT BASE TO BARREL
SECTION ON INSIDE
PRE-FORMED PLASTIC GASKET
CAST-IN-PLACE CONCRETE BASE
16 IN. MAX.
FINISHED GRADE
30 IN. MIN.
48 IN. MAX.
VARIABLE
28 IN. MAX.
24 IN.
SEE TABLE
6 IN.
12 IN.
SLOPE
1 IN./FT.
18 IN.
MAX.
MANHOLE RUNGS
12 IN. O.C.
8 IN. MIN
DATE REVISED:
SEWER CONSTRUCTION DETAILS APPROVED: DRAWN BY: DETAIL
STANDARD MANHOLE
WW-3
NBJ
4/11/11
NOT TO SCALE
202
C601
TRAFFIC RATED CLEANOUT
W/ SEWER STAMPED ON LID
VALVE BOX
\A1;6" MIN
\A1;WATER TIGHT SCREW CAP
\A1;4"
HARD ASPHALT SURFACE OR OTHER
FLOW DIRECTION
DATE REVISED:
SEWER CONSTRUCTION DETAILS APPROVED: DRAWN BY: DETAIL
TRAFFIC RATED CLEANOUT
WW-15
NBJ
4/11/11
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
NOT TO SCALE
100
C600
WATER MAIN BEDDING
BOTTOM OF PIPE AND A MINIMUM OF 12 INCHES ABOVE TOP OF PIPE.
GRANULAR BEDDING MATERIAL SHALL BE A MINIMUM OF 4 INCHES BELOW
INITIAL 12 IN. LIFT MIN.
PIPE O.D.
4 IN. MIN.
GRANULAR MATERIAL
BEDDING ZONE
%%UNOTE:
* INITIAL LIFT SHALL NOT EXCEED 2 FEET IN DEPTH.
TRENCH WALL
LOWER LIMIT OF
SLOPING
TRENCH IN WIDTH SECTION AS 02221 SPECIFIED
*
REVISED DATE:
DETAIL
TITLE OF DRAWING
FIELD OPERATIONS
(970) 221-6700
UTILITIES - WATER
FORT COLLINS, CO. 80550
CITY OF FORT COLLINS
P.O. BOX 580
WATER MAIN BEDDING
REQUIREMENTS (DIP & PVC) 1
4/8/11
PIPE
SIZE BENDS TEE OR
DEAD
END
22 1/2%%D 45%%D 90%%D
6"
8"
12"
1.0
1.5
3.0
1.5
2.5
4.5
2.5
4.5
9.0
4.5
8.0
16.5
3.5
5.5
12.0
MINIMUM BEARING SURFACE AREA
(SQ. FT.)
Bearing surface areas shown in chart are minimum.
All fittings to be wrapped with polyethylene.
Pipe installed under conditions different from those
normally encountered shall require thrust blocks
designed for those particular conditions.
Thrust blocks on pipe larger than 16 inches diameter
shall be designed for conditions existing at the
installation site.
Refer to Section 03300 for concrete requirements.
1.
2.
3.
4.
5.
GENERAL NOTES:
UNDISTURBED
SOIL
POLYETHYLENE
BOND BREAKER
UNDISTURBED
SOIL
BOND BREAKER
POLYETHYLENE BEARING
SURFACE
POLYETHYLENE
BOND BREAKER
UNDISTURBED
SOIL
BEARING
SURFACE
SOIL
UNDISTURBED
BEARING
SURFACE
POLYETHYLENE
BOND BREAKER
BEDDING
MATERIAL
2/3 DIA.
%%UTEE
%%UTYPICAL BEND
%%UTYPICAL CROSS-SECTION
%%UDEAD END
BEARING SURFACES ARE A MINIMUM REQUIREMENT
AND DO NOT RELIEVE DESIGN ENGINEER OF
RESPONSIBILITY TO DESIGN EACH THRUST BLOCK.
16" 4.8 9.6 18.9 34.7 24.5
REVISED DATE:
DETAIL
TITLE OF DRAWING
FIELD OPERATIONS
(970) 221-6700
UTILITIES - WATER
FORT COLLINS, CO. 80550
CITY OF FORT COLLINS
P.O. BOX 580
STANDARD CONCRETE
THRUST BLOCKS
2
4/8/11
DESIGNATED SPRINKLER SERVICE
FLOW
5 FT. MIN.
METER
PIT
AIR-INJECTION PORT
(TOP OF PIPE MAX. 1/4"
PIT
METER
5 FT. MIN.
FLOW
SPRINKLER TAP OFF DOMESTIC SERVICE
SERVICE MAIN
VACUUM BREAKER
VACUUM BREAKER
(FROM OUTLET SIDE OF
METER PIT TO
SHUT-OFF VALVE TEE)
IRRIGATION SHUT-OFF VALVE
AIR-INJECTION
PORT DOWNSTREAM OF
VACUUM BREAKER
SPRINKLER TEE)
METER PIT TO
(FROM OUTLET SIDE OF
(STOP AND WASTE VALVE NOT PERMITTED)
IRRIGATION SHUT-OFF VALVE
(STOP AND WASTE VALVE NOT PERMITTED)
DIA. WITH CAP OR PLUG)
AIR-INJECTION PORT
(TOP OF PIPE MAX. 1/4"
DIA. WITH CAP OR PLUG)
(3/4" OR LARGER
RECOMMENDED)
RECOMMENDED)
(3/4" OR LARGER
PORT DOWNSTREAM OF
VACUUM BREAKER
AIR-INJECTION
REVISED DATE:
DETAIL
TITLE OF DRAWING
FIELD OPERATIONS
(970) 221-6700
UTILITIES - WATER
FORT COLLINS, CO. 80550
CITY OF FORT COLLINS
P.O. BOX 580
SPRINKLER SYSTEM DETAIL
13
8/4/15
GENERAL NOTES:
1/4" HOLE
IN HANDLE
1 1/2" BALL VALVE
6. %METER %INSTALLATION UPLAN DESIGN FOR 6 VIEW IN. AND LARGER METERS SHALL BE DETERMINED BY THE 1 1/UTILITY. 2" CAP
5. FOR IRRIGATION ONLY SERVICES, NO BYPASS ALLOWED.
4.
3.
GATE VALVES MUST OPEN RIGHT AND BE EPOXY COATED, RESILIENT SEAT WITH A HAND WHEEL ASSIST.
ALL PIPING WITHIN VAULT SHALL BE D.I.P. WITH FLANGED FITTINGS, EXCEPT FOR THE SOLID SLEEVES.
2. ALL JOINTS OUTSIDE OF VAULT SHALL BE RESTRAINED MECHANICAL JOINTS. (REFERENCE SECTION 02615)
1.
THE BUILDING IMMEDIATELY FOLLOWING THE MAIN SHUT OFF VALVE.
IF A PRESSURE REDUCING VALVE IS REQUIRED BY PLUMBING CODE, INSTALL VALVE INSIDE
7. LOCATION AND ALIGNMENT OF AMR POD(S) ON VAULT TOP CAN VARY.
%%UTEST-TEE SIDE VIEW
SEE DETAIL
TEST-TEE
BELOW LID)
24" DIA.
FOR H-20 BRIDGE LOADING
PRECAST CONCRETE VAULT DESIGNED
STRAINER
7'-0"
1'-6" 2'-6"
METER (PLACED
FLOW
SLEEVE
SOLID
VALVE
VALVE GATE
GATE
SLEEVE
SOLID
8'-6"
AMR POD(S) (FORD YOKE BOX
PART #YUC-7 WITH FORD
YOKE BOX LID PART #YL-TP
WITH 1 27/32" DIA. HOLE
AND REMOVABLE PLUG)
ANCHOR RODS
PROTECTIVE COATING
(TYP.) WITH
GATE
VALVE
FLOW
FLOW FLOW
ACCESS
OPENING
LADDER RUNG
VAULT ACCESS
PRECAST CONCRETE OR FOOTING CAST IN PLACE
18" DIA.
PERFORATED
PIPE SUMP
8. A SEPERATE AMR POD MUST BE INSTALLED FOR EACH METER REGISTER.
REVISED DATE:
DETAIL
TITLE OF DRAWING
FIELD OPERATIONS
(970) 221-6700
UTILITIES - WATER
FORT COLLINS, CO. 80550
CITY OF FORT COLLINS
P.O. BOX 580
STANDARD SETTING FOR 3 IN. AND
4 IN. WATER METERS (PLAN VIEW) 17A
4/11/11
1. DO NOT INSTALL IN ANY STREET, ALLEY, PARKING AREA, DRIVEWAY, SIDEWALK DRAINAGE DITCH OR DETENTION BASIN.
2. NO LANDSCAPING (SHRUBS, BOULDERS, ECT.) OR STRUCTURES TO BE WITHIN 4 FT. OR TREES WITHIN 10 FT.
OF METER VAULT.
3. SLOPE GROUND SURROUNDING METER VAULT AWAY FROM LID AT 2%%% GRADE OR GREATER.
4. MAKE NO PLUMBING CONNECTIONS (TEES, COUPLINGS, ECT.) IN METER VAULT.
5. GRADE ACCEPTANCE AFTER METER PIT INSTALLATION REQUIRES THAT THE OWNER ADJUST METER VAULT COVER
TO 1/2 IN. ABOVE FINAL GRADE.
6. IF A PRESSURE REDUCING VALVE IS REQUIRED BY PLUMBING CODE, IT SHALL BE INSTALLED INSIDE THE BUILDING,
IMMEDIATELY FOLLOWING THE MAIN SHUT-OFF VALVE.
GENERAL NOTES:
ADJUSTABLE PIPE SUPPORT
UNDER VALVES AND METER
3/4" TO 1-1/2"
GRAVEL
ASPHALTIC
GROUT
SOLID PAVING
BRICK (TYPICAL)
PRE-FORMED
PLASTIC GASKETS
PIPE ENCASED
WITH MASTIC
GATE
VALVE STRAINER
SOLID
SLEEVE
GATE
VALVE
MANHOLE RUNGS
12 INCHES O.C.
FINISHED GRADE 2% SLOPE
INSTALL LID 1/2"
ABOVE FINAL GRADE
ALUMINUM MANHOLE COVER
AND RING WITH LID LOCK
MORTAR OR
LIFTING HOOK MASTIC
FLOW
BLOCK-OUT TO
BE GROUTED
54" (MIN.)
6" (MAX.)
7" (MIN.)
16" (MAX.)
GRADE PRE-RINGS CAST CONCRETE (IF REQUIRED)
10"
30"
8"
8"
(TYPICAL) ANCHOR RODS
(TYP.) WITH
PROTECTIVE
1" (MAX.)
CONDUIT THROUGH
INTO YOKEBOX
VAULT OR PIT TOP
1/2" EMT OR PVC
3" (MAX.)
AND REMOVABLE PLUG)
YOKE WITH PART BOX #1 YUC-27/LID 32" 7 PART WITH DIA. HOLE FORD #YL-TP
AMR POD (FORD YOKE BOX
FINISHED GRADE
BE 1/2" ABOVE
TOP OF AMR LID TO
2'
3/4" ROCK FOR
GRADE ADJUSTMENT
(MAX.)
(IF REQ'D)
(TYP.)
(TYP.) 66" (MAX.)
12"
(TYP.)
PRECAST OR CAST
IN PLACE CONCRETE
FOOTING (TYP.)
PIPE 18" SUMP DIA. PERFORATED
REVISED DATE:
DETAIL
TITLE OF DRAWING
FIELD OPERATIONS
(970) 221-6700
UTILITIES - WATER
FORT COLLINS, CO. 80550
CITY OF FORT COLLINS
P.O. BOX 580
STANDARD SETTING FOR 3 IN. AND
4 IN. WATER METERS (SIDE VIEW) 17B
4/11/11
COATING
SERVICE LINE BY-PASS
30"
54" (MIN.)
8"
8"
10"
6" (MAX.)
12 INCHES MANHOLE O.RUNGS C.
AND RING WITH LID LOCK
ALUMINUM MANHOLE COVER
MORTAR OR
MASTIC PRE-CAST GRADE CONCRETE RINGS (IF
PLASTIC GASKETS
PRE-FORMED LIFTING HOOK
REQUIRED)
3/4" TO 1-1/2"
GRAVEL
PRECAST OR CAST
IN PLACE CONCRETE
FOOTING (TYP.)
(TYP.) 66" (MAX.)
12"
(TYP.)
REVISED DATE:
DETAIL
TITLE OF DRAWING
FIELD OPERATIONS
(970) 221-6700
UTILITIES - WATER
FORT COLLINS, CO. 80550
CITY OF FORT COLLINS
P.O. BOX 580
STANDARD SETTING FOR 3 IN. AND
4 IN. WATER METERS (END VIEW) 17C
4/11/11
CP
TEST STATION
U
S
A
\A1;1 1/8"
7/16"
3 1/2"
7 5/16"
5/2" 8"
A
S
U
I
E
J
W
STATION
LOCATOR
LID PLAN VIEW
LID SECTION VIEW
VALVE BOX SECTION VIEW
9"
6 1/8"
10"
\A1;7 9/16"
2 1/16"
CLOSED PICKHOLE
(TYPICAL OPPOSITE
SIDE)
1/2" RAISED LETTERING
(RECESSED FLUSH)
REFERENCE SPECIFICATIONS 02622-2
THROUGH 02622-4 FOR LOCATOR
FOR CP TEST STATION INFORMATION.
REFERENCE SPECIFICATIONS 16640-5
STATION BOX INFORMATION.
REVISED DATE:
DETAIL
TITLE OF DRAWING
FIELD OPERATIONS
(970) 221-6700
UTILITIES - WATER
FORT COLLINS, CO. 80550
CITY OF FORT COLLINS
P.O. BOX 580
CP TEST AND LOCATOR STATION BOX
25
W
J
E
I
NOT TO SCALE
101
C600
STANDARD CONCRETE TRUST BLOCKS
NOT TO SCALE
102
C600
SPRINKLER SYSTEM DETAIL
NOT TO SCALE
103
C600
STANDARD SETTING FOR 3 IN. AND
4 IN. WATER METERS (PLAN VIEW)
NOT TO SCALE
104
C600
NOT TO SCALE
105
C600
NOT TO SCALE
106
C600
STANDARD SETTING FOR 3 IN. AND CP TEST AND LOCATOR STATION BOX
4 IN. WATER METERS (SIDE VIEW)
STANDARD SETTING FOR 3 IN. AND
4 IN. WATER METERS (END VIEW)
PVI ELEV = 5035.90
PVI STA = 13+20.33
PVI ELEV = 5035.68
PVI STA = 13+38.65
PVI ELEV = 5035.45
PVI STA = 13+75.31
PVI ELEV = 5034.97
EXISTING
GROUND
PROPOSED
GRADE
PROPOSED
GRADE
EXISTING
GROUND
/ / / / / / / / / / / / / / / /
/ / / / / / / /
T T T T T T T
VAULT
ELEC
VAULT
ELEC
ST
X
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
D D
D
TF
FDC
PLUM STREET
(ROW VARIES)
CITY PARK AVENUE
5' CURB TRANSITION
7' SIDEWALK
9' UTILITY EASEMENT
±40' -
66' ROW
EXISTING 30" VERTICAL
CURB & GUTTER
PROPOSED 30" VERTICAL
CURB & GUTTER
PAVEMENT
MILL & OVERLAY AREA
NEW PAVEMENT
AREA
LIMIT OF
MILL & OVERLAY
LIMIT OF
MILL & OVERLAY
EXISTING STRIPING
TO BE REPLACED
EXISTING 30" VERTICAL
CURB & GUTTER
7' SIDEWALK
9' UTILITY EASEMENT
LIMIT OF NEW
PAVEMENT
DETENTION OUTFALL
SEE SHEET C301
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
C500
PLAN & PROFILE
WEST PLUM STREET A. Reese
B. Ruch
1"=20'
No. Revisions:
By: Date:
REVIEWED BY:
N. Haws
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
Feb. 22, 2017
PROJECT:
1252-001
Sheet
of 17 Sheets
WEST PLUM HOUSING
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
02/22/17
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
NORTH
( IN FEET )
1 inch = ft.
20 0 20 Feet
20
40 60
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED
IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
3. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION,
AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED
OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR
RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE
PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE
ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
4. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN, AND
RECOMMENDATIONS.
LEGEND:
PROPOSED CURB & GUTTER
PROPOSED EASEMENT LINE
PROPERTY BOUNDARY
EXISTING FENCE
X
RIGHT FLOWLINE
WEST PLUM STREET
SCALE : 1" = 20' (H) 1" = 5' (V)
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED PEDESTRIAN
ACCESS RAMPS
ASPHALT MILL & OVERLAY
ASPHALT PATCH
41.22
41.38
37.05
42.50
37.05
39.05
39.05
36.47
36.42
43.05
37.05
39.05
39.05
36.27
36.23
40.20
37.05
40.13
40.13
39.56
40.05
40.12
39.54
39.78
39.78
40.07
39.98
38.05
37.97
37.95
39.24
39.30 37.50
38.77
38.85
38.77
38.89
41.15
41.25
41.25
41.15
38.87
40.99
41.09
40.14
40.04
37.03
37.04
37.14
36.65
36.39
37.00
37.00
39.53
2.0% 5.0%
5.2%
0.2%
3.2%
5.0%
2.0%
2.0%
2.0%
2.0% 4.2%
2.0%
2.0% 0.5%
8.2%
2.0%
0.5%
1.0%
2.0%
1.5%
1.0%
2.1%
1.0%
2.0%
0.5% 0.5%
2.0%
0.5%
2.0%
0.5%
2.5%
0.5% 0.5%
2.0%
0.5%
2.0%
FFE=39.68
2.0%
2.0%
6.0% 2.0%
2.0%
2.5%
1.0%
2.8%
1.4%
1.1%
2.5%
2.3%
2.5%
2.1%
2.1%
2.5%
2.5%
2.6%
0.8%
2.8%
6.3%
2.1%
2.1%
5.2%
4.2%
2.3%
2.0%
0.1%
0.5% 0.5%
40.02
FFE=41.25
38.36
TRENCH DRAIN
(RE: PLUMBING)
DRAIN BASIN
(RE: PLUMBING)
DRAIN BASIN
(RE: PLUMBING)
DETENTION OUTFALL
SEE SHEET C301
SAND FILTER
TOP SAND ELEV.= 5037.05
BOTTOM SAND ELEV.=5036.05
DETENTION AREA
WITH NO. 4 ROCK
COBBLE BOTTOM
40.02
37.31
37.01
36.82
36.82
37.01
36.49
35.19
36.23
36.33
36.39
41.86
39.63
39.09
1.1%
0.8%
40.20
40.20
37.76
39.06
39.09
37.01
37.01
40.30
PROVIDE (9) 1" Ø WEEP HOLES SPACED 5' O.C.
ALONG WALL AT ELEVATION ± 5036.50.
SLOPE WEEP HOLE TO PREVENT SAND FROM
PASSING THROUGH WALL.
39.77
40.20
40.20
40.20
40.20
40.20
2.1%
INSTALL STEEL ACCESS
RAMP FOR MAINTENANCE
10:1 MAX. SLOPE
(RE: ARCH. PLANS)
DETENTION OUTLET
STRUCTURE
(SEE DETAILS)
36.27
RAMP LANDING
EL= 5038.35
(RE: ARCH. PLANS)
RAMP LANDING
EL= 5040.30
(RE: ARCH. PLANS)
A A
FFE=40.20
36.13
2.1%
100-YR WSEL = 5039.50
MIN. GARAGE ELEV. = 5040.30
STORM DRAIN
INV.=5037.05
TOP OF SAND = 5037.05
12" SAND LAYER
10' WIDE
SAND FILTER 17' WIDE DETENTION VAULT
1" Ø WEEP HOLE
OUTLET
STRUCTURE
INV. = 5036.13
8" STORM
OUTFALL PIPE
TOP OF WALL
EL.=5039.05
NOTE:
REFER TO STRUCTURAL PLANS
FOR ADDITIONAL VAULT INFORMATION
3" LAYER OF
NO. 4 ROCK COBBLE
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
C402
GARAGE GRADING PLAN
A. Reese
B. Ruch
1"=10'
No. Revisions:
By: Date:
REVIEWED BY:
N. Haws
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
Feb. 22, 2017
PROJECT:
1252-001
Sheet
of 17 Sheets
WEST PLUM HOUSING
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
02/22/17
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
NORTH
( IN FEET )
1 inch = ft.
10 0 10 Feet
10
20 30
DETAILED GRADING - GARAGE
LEGEND:
5013
PROPOSED CONTOUR
EXISTING CONTOUR
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
33.43
PROPOSED SLOPES
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
4. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM NAVD88.
SEE COVER SHEET FOR BENCHMARK REFERENCES.
5. THE BOTTOM OF MASONRY SHALL GENERALLY FOLLOW FINISHED GRADES. THERE
SHALL BE A MAXIMUM OF 12" EXPOSED CONCRETE BETWEEN THE FINISHED GRADE
AND ALL MASONRY.
NOTES:
2.0%
(47.45)
EXISTING SPOT ELEVATION
PROPOSED STORM
PROPOSED VERTICAL
CURB AND GUTTER
SECTION A-A
FFE=41.25
FFE=41.25
41.20
42.08
41.50
41.75
41.75
40.92
40.92
41.75
41.90
42.08
41.75
42.08
42.08
42.08
42.08
41.91
40.76
40.92
40.92
40.92
40.92
41.03
40.99
40.94
40.75
40.74
41.01
41.08
43.13
43.08
(40.98)
(40.76)
(40.27)
(40.16)
41.08
41.10
41.06
42.89
40.89
40.81
40.89
2.00%
0.75%
0.66%
0.50%
0.75%
0.75%
0.70%
41.10
41.13
40.93
40.85
41.02
40.68
40.95
40.88
40.80
40.84
40.68
40.65
40.57
42.48
42.48
42.48
42.43
40.60
40.56
43.03
40.84
(40.86)
41.34
40.80
40.80
40.80
0.75%
0.76%
1.00%
1.00%
1.00%
1.00%
1.00%
1.00%
1.00%
1.00%
1.00%
0.00%
2.34%
231.37%
11.3%
25.0%
8.4% 6.6%
6.3%
6.3%
6.4% 6.6%
5.3%
17.5%
1.00%
40.42
1.00%
0.50%
40.29
41.48
41.75
40.22
1.00%
1.00%
1.00%
5.2%
6.4%
41.75
6.5%
9.9%
CHASE INV. =
5040.03
CHASE INV. = 5040.14
CHASE INV. = 5040.33
CHASE INV. =
5040.34
CHASE INV. =
5040.51
CHASE INV. =
5040.19
(40.66)
(40.87)
40.85
40.76
40.85
2.1%
2.0%
18.1%
2.6%
4.3%
(39.95)
PLANTER WALL
RE: LANDSCAPE)
SEAT WALL
RE: LANDSCAPE)
PLANTER WALL
RE: LANDSCAPE)
PLANTER WALL
RE: LANDSCAPE)
PLANTER WALL
RE: LANDSCAPE)
TW=5041.72
TW=5041.47
TW=5041.47
TW=5041.90
TW=5041.90
TW=5041.90
TW=5042.25
TW=5042.25
TW=5042.78
TW=5043.28
TW=5043.28
TW=5043.28
X X X X
X X X
X X X X
X X X X
X X X X
FDC
41.47
39.98
40.03
40.92
40.92
40.92
40.92
FFE=41.25
FFE=41.25
FFE=41.25 FFE=41.25
FFE=41.25
(39.32)
(39.02)
UTILITY EASEMENT
40.29
41.48
41.75
40.22
39.99
1.00%
1.00%
1.00%
1.00%
39.87
39.72
1.00%
1.00%
1.00%
9.9%
6.5%
10.9%
12.1%
14.8%
11.4%
10.7%
39.22
39.99
40.03
41.24
41.11
40.92
39.99
41.51
42.08
42.08
41.86
41.86
42.08
42.08
42.08
41.75
41.40
40.92
40.92
40.92
42.08
40.92
42.08
42.08
40.40
39.79
40.58
39.75
39.77
5.1%
7.87% 7.87%
9.96%
39.89
CHASE INV. = 5039.22
0.80%
(1.0%)
7.7%
2.1%
(39.95)
(39.69)
(39.51)
PLANTER WALL
RE: LANDSCAPE)
PLANTER WALL
RE: LANDSCAPE)
PLANTER WALL
RE: LANDSCAPE)
PLANTER WALL
RE: LANDSCAPE)
TW=5041.00
TW=5041.00
TW=5041.25
TW=5041.25
TW=5041.72
TW=5041.72
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
C401
COURTYARD GRADING PLAN
A. Reese
B. Ruch
1"=5'
No. Revisions:
By: Date:
REVIEWED BY:
N. Haws
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
Feb. 22, 2017
PROJECT:
1252-001
Sheet
of 17 Sheets
WEST PLUM HOUSING
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
02/22/17
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
NORTH
( IN FEET )
1 inch = ft.
5 0 5 Feet
5
10 15
DETAILED GRADING - EAST COURTYARD
DETAILED GRADING - WEST COURTYARD
LEGEND:
5013
PROPOSED CONTOUR
EXISTING CONTOUR
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
33.43
PROPOSED SLOPES
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
4. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM NAVD88.
SEE COVER SHEET FOR BENCHMARK REFERENCES.
5. THE BOTTOM OF MASONRY SHALL GENERALLY FOLLOW FINISHED GRADES. THERE
SHALL BE A MAXIMUM OF 12" EXPOSED CONCRETE BETWEEN THE FINISHED GRADE
AND ALL MASONRY.
NOTES:
2.0%
(47.45)
EXISTING SPOT ELEVATION
PROPOSED STORM
PROPOSED VERTICAL
CURB AND GUTTER
X
X
X
X
D D
D
TF
UD UD UD UD UD UD
FDC
FDC
PLUM STREET
(ROW VARIES)
5' UTILITY EASEMENT
UTILITY EASEMENT
5' UTILITY EASEMENT
PROPOSED CONCRETE
COLLAR & CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 5'
WALK w/ PAN
PROPOSED 1'
SIDEWALK CHASE PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
9' UTILITY EASEMENT
THE LOFTS AT CAMPUS WEST
TOWN SQUARE
CONDOMINIUMS
CITY PARK CONDOMINIUMS
(BOOK 1291, PAGE 862)
THE DISTRICT AT CAMPUS WEST
(REC. NO. 20130032356)
OPEN BOTTOM
DETENTION VAULT
FFE=41.25
FFE=39.30
FFE=41.25
FFE=
39.68
41.75
40.40
39.74
38.65
36.95
37.01
36.49
36.83
36.37
35.87
35.05
35.81
35.90
36.01
35.75
36.25
36.39
36.65
36.51
36.20
35.58
34.97
36.25
36.55
37.50
36.71
38.34
37.81
37.71
37.87
37.25
37.43
38.40
38.86
38.65
38.04
38.89
38.93
38.22
38.84
39.01
40.78
39.67
39.94
40.76
38.22
40.65
36.83
40.65
38.57
38.31
38.70
(40.01)
40.51
40.81
40.89
40.89
40.59
40.58
39.74
41.17
38.87
38.77
39.30
39.56
37.95
39.30
37.00
36.39
37.15
37.03
41.10
41.75
41.75
42.08
42.08
41.86
41.88
39.44
39.29
40.12
40.44
39.32
39.20
38.89
40.51
40.51
39.80
39.31
39.27
38.75
38.79
38.26
38.22
37.95
38.09
36.39
36.23
36.25
(35.09)
(35.63)
(35.79)
40.32
(40.58)
(40.61)
40.48
0.6%
0.8%
(39.02)
PROPOSED 6'
SIDEWALK
PROPOSED 7'
SIDEWALK
44' -
40' -
38.46
38.36
5' CURB
TRANSITION
39.68
(36.80)
(35.62)
(36.00)
(40.93)
TIE TO EXISTING
SIDEWALK
R20' R15' R15'
36.61
36.25
43.55
41.86
TIE TO EXISTING
SIDEWALK
(6) 7" RISERS (4) 7" RISERS
(2) 7" RISERS (3) 7" RISERS (4) 7" RISERS
(1) 6" RISER
37.00
40.04
39.75
39.74
41.25
39.97
40.58
40.58
39.72
39.01
38.88
38.38
39.23
39.23
38.38
38.75
38.75
37.24
37.07
41.15
41.25
38.85
40.41
41.25
40.99
41.09
(40.89)
(40.29)
(40.16)
1.4%
7.9%
6.0%
4:1
5:1
9:1
12:1
5:1
39.58
2.2%
5.1%
1.6%
2.3%
1.0%
41.15
41.25
10.5%
9' UTILITY EASEMENT
40.02
40.15
39.66
39.90
40.04
39.45
39.41
39.31
40.33
38.77
36.99
36.82
36.77
36.91
37.10
DETENTION OUTFALL
SEE SHEET C301
N:127177.22
E:188606.38
N:127156.10
E:188593.34
N:126964.67
E:188604.53
N:126964.51
E:188487.96
N:126974.98
E:188590.10
N:126976.58
E:188499.45
N:127062.74
E:188488.37
N:127069.63
E:188215.75
N:127080.94
E:188238.50
N:127182.65
E:188216.54
N:127161.56
E:188236.91
PROPOSED
TRENCH DRAIN
(RE: PLUMBING)
PROPOSED
OUTLET STRUCTURE
PROPOSED TRENCH DRAIN
(RE: PLUMBING)
PROPOSED DRIVE WAY
PER LCUASS
38.96
40.27
(6) 6" RISERS
39.65
43.00
41.80
41.81
41.90
41.38
42.50
43.05
39.24
37.50
36.17
36.82
37.01
36.47
40.14
35.10
36.29
36.82
42.08
(39.32)
42.08
42.08
41.86
41.85
40.59
(41.10)
40.58
40.29
40.20
40.08
40.00
1.5%
1.5%
1.5%
1.5%
1.2%
41.20
38.66
5.0%
2.0%
37.31
37.76
37.01
37.97
2.0%
36.78
38.27
2.0%
35.95
8.4%
39.89
WEST COURTYARD
SEE SHEET C401
EAST COURTYARD
SEE SHEET C401
42.08
42.08
42.07
42.07
41.86
41.88
41.71
41.70
41.71
41.45
42.02
42.08
41.14
41.18
41.21
41.25
39.17
38.89
38.96
38.65
38.25
8.0%
8.0%
GARAGE
SEE SHEET C402
SAND FILTER
PROPOSED DRAIN BASIN
(RE: PLUMBING)
PROPOSED DRAIN BASIN
(RE: PLUMBING)
41.22
40.34
41.58
41.49
40.24
39.42
38.81
38.04
37.25
37.06
37.64
38.61
39.35
39.82
36.79
36.76
36.43
FFE=
40.20
39.56
LEGEND:
5013
PROPOSED CONTOUR
EXISTING CONTOUR
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
33.43
PROPOSED SLOPES
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
4. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM NAVD88.
SEE COVER SHEET FOR BENCHMARK REFERENCES.
5. THE BOTTOM OF MASONRY SHALL GENERALLY FOLLOW FINISHED GRADES. THERE
SHALL BE A MAXIMUM OF 12" EXPOSED CONCRETE BETWEEN THE FINISHED GRADE
AND ALL MASONRY.
NOTES:
2.0%
(47.45)
EXISTING SPOT ELEVATION
PROPOSED STORM
PROPOSED VERTICAL
CURB AND GUTTER
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
C400
GRADING PLAN
A. Reese
B. Ruch
1"=20'
No. Revisions:
By: Date:
REVIEWED BY:
N. Haws
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
Feb. 22, 2017
PROJECT:
1252-001
Sheet
of 17 Sheets
WEST PLUM HOUSING
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
02/22/17
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
NORTH
( IN FEET )
1 inch = ft.
20 0 20 Feet
20
40 60
D D
FDC
W
F F
S
F
TF
9' UTILITY
EASEMENT
5' UTILITY EASEMENT
PLUM STREET
(ROW VARIES)
TOWN SQUARE
CONDOMINIUMS
THE LOFTS AT CAMPUS WEST
OPEN BOTTOM
DETENTION VAULT
BASIN A1
STA 11+11.86
N: 127044.91
E: 188597.86
OUTLET STRUCTURE A2
STA 11+21.55
N: 127045.08
E: 188588.17
FES A
STA 10+00.00
N: 127156.75
E: 188599.83
111.86 LF 8" PVC @ 0.50%
9.70 LF 8" PVC @ 2.70%
EXISTING 12" PVC
SANITARY SEWER
EXISTING FH
PROPOSED CONCRETE
COLLAR & CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED
WATER METER
EXISTING 20"
WATER LINE
PROPOSED 4"
WATER SERVICE
PROPOSED 6"
FIRE SERVICE
PROPOSED ELECTRIC
TRANSFORMER
PROPOSED 8"
SANITARY SERVICE
N:127177.22
E:188606.38 N:126964.67
E:188604.53
N:126974.98
E:188590.10
N:127156.05
E:188593.29
PROPOSED TRENCH DRAIN
(RE: PLUMBING)
SAND FILTER
5025
5030
5035
5040
5045
5050
5055
5025
5030
5035
5040
5045
5050
5055
9+75 10+00 11+00 11+50
111.86 LF 8" PVC @ 0.50%
9.70 LF
8" PVC
@ 2.70%
BASIN A1
STA 11+11.86
RIM 5037.4±
INV. IN 5035.75 (W)
INV. OUT 5035.75 (N)
OUTLET STRUCTURE A2
STA 11+21.55
INV. 5036.01 (E)
FES A
STA 10+00.00
INV. 5035.19 (S)
EXISTING
GROUND
PROPOSED
GROUND
NORTH
( IN FEET )
1 inch = ft.
20 0 20 Feet
20
40 60
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
C301
PLAN & PROFILE
DETENTION OUTFALL A. Reese
B. Ruch
1"=20'
No. Revisions:
By: Date:
REVIEWED BY:
N. Haws
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
Feb. 22, 2017
PROJECT:
1252-001
Sheet
of 17 Sheets
WEST PLUM HOUSING
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
02/22/17
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
EXISTING RIGHT OF WAY
EXISTING WATER MAIN
LEGEND:
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
3. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS AND SERVICES.
5. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
6. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
W
G
T
E
EXISTING STORM SEWER
PROPOSED ELECTRIC
EXISTING TELEPHONE
EXISTING GAS
PROPOSED SEWER SERVICE S
PROPOSED FIRE SERVICE F
EXISTING SANITARY SEWER SS
PROPOSED FIRE DEPT. CONN.
PROPOSED CURB & GUTTER
PROPOSED CURB STOP & METER PIT
FDC
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT H Y
D
PROPERTY BOUNDARY
EASEMENT LINE
EXISTING FIBER OPTICS FO
PROPOSED STORM SEWER
PROPOSED WATER MAIN
PROPOSED SANITARY SEWER
W
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=20'
DETENTION OUTFALL
/ / / / / / / /
/ / / / / / / /
FO
X
X
X
G
G G G
FO FO FO
VAULT
ELEC
S
S
H
Y
D
WV
WV
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
VAULT
ELEC FO
VAULT
ELEC
T FO
E
X
X
X
X
X
X
CTV
CTV
CTV
CTV CTV
FO FO FO
FO FO
FO
FO FO
E E
E E E
E E
E E E
E E
E E
E E
E E E
E
E
E
CTV CTV CTV
CTV CTV CTV
CTV CTV CTV CTV
CTV CTV CTV
FO FO FO
FO FO FO
FO FO FO FO
FO FO FO
W W
W W
W
W
W
W W W W
W W
W W
W W W W
W
W W W
W
W W
G
G G
G G
G
G
G G
G
G
G G G
G
G G G
G
G G G
G
G G
G
G
G
E E
E E
SS SS SS
SS SS SS SS SS SS SS SS SS SS SS SS
S
W W
W
W
D D
D
FDC
FDC
SS SS
S
W
S
G G G G
E E E E E E E E E E E E
E E
E E E E E E E
UD UD UD UD UD UD
F F F F F
E E E
E
E E
E E E
E
E
E E E E
F F F
F
F
W
F F
S
F
TF
G G G G G
E E E E
9' UTILITY EASEMENT 9' UTILITY EASEMENT
5' UTILITY EASEMENT
UTILITY EASEMENT
5' UTILITY EASEMENT
PLUM STREET
(ROW VARIES)
THE LOFTS AT CAMPUS WEST
TOWN SQUARE
CONDOMINIUMS
CITY PARK CONDOMINIUMS
(BOOK 1291, PAGE 862)
THE DISTRICT AT CAMPUS WEST
(REC. NO. 20130032356)
OPEN BOTTOM
DETENTION VAULT
UTILITY EASEMENT
CONNECT TO EXISTING 20" WATER MAIN
20"x3" TAPPING SADDLE w/ 3" GV (S) & TB
N:127201.65
E:188581.52
CONNECT TO EXISTING 20" WATER MAIN
20"x6" TAPPING SADDLE w/ 6" GV (S) & TB
N:127201.56
E:188586.44
CUT IN MANHOLE CONNECT TO
EXISTING 12" SANITARY SEWER
N:127193.50
E:188543.97
SSMH A
INV. IN=5026.76 (W)
INV. IN=5027.09 (S)
INV. OUT=5026.76 (E)
FG=5036.03
8" SANITARY SERVICE
INV. OUT=5027.41 (N)
FG=5036.68
PROPOSED ±42 LF
3" WATER SERVICE
PROPOSED ±42 LF
6" FIRE SERVICE
N:126964.51
E:188487.96
N:126964.67
E:188604.53
N:126974.98
E:188590.10
N:126976.58
E:188499.45
N:127177.22
E:188606.38
N:127156.05
E:188593.29
N:127074.31
E:188501.17
N:127080.94
E:188238.50
N:127161.56
E:188236.91
N:127182.65
E:188216.54
N:127069.63
E:188215.75
/ / / / / /
/ / /
/ / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / /
/
/ / / / / /
/ / / / / / / / /
/ / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / /
/ / / / / / / / / / /
/ / / / / / / / / / /
/ / / / / /
/
/ / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / /
/ /
/ / /
/ / / / / / / / /
/
/
/
/
/
/
/ / / / / / / / / / / / / / / / / / / /
/
/
/
/ / / / / / / / / / / / /
/ / / / / / / / / / /
/
/
/ / / / / / / / /
/
/ / / / / / / / / /
/
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / /
/ / / / / /
/ / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / /
/ /
/ / / / /
EXISTING 20"
WATER LINE
EXISTING 12" PVC
SANITARY SEWER
EXISTING FH
EXISTING FH
PROPOSED CONCRETE
COLLAR & CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 5'
WALK w/ PAN
PROPOSED 12" PVC
STORM DRAIN
PROPOSED ELECTRIC
TRANSFORMER
PROPOSED 3"
WATER METER
EXISTING FH
PROPOSED EXTERIOR
STANDPIPE CONNECTION
PROPOSED
ELECTRIC METERS
EXMH
RIM=5035.26
INV IN=5026.56 (W)
INV IN=5026.93 (S)
INV OUT=5026.51 (E)
EXMH
RIM=5036.72
INV IN=5027.06 (W)
INV IN=5027.22 (N)
INV OUT=5026.99(E)
DETENTION OUTFALL
SEE SHEET C301
EXISTING 20"
WATER LINE
EXISTING WATER
SERVICE TO BE
ABANDONED AT MAIN
EXISTING WATER
SERVICE TO BE
ABANDONED AT MAIN
EXISTING WATER
SERVICE TO BE
ABANDONED AT MAIN
EXISTING WATER
SERVICE TO BE
ABANDONED AT MAIN
APPROXIMATE LOCATION
EXISTING WATER
SERVICE TO BE
ABANDONED AT MAIN
APPROXIMATE LOCATION
EXISTING WATER
SERVICE TO BE
ABANDONED AT MAIN
EXISTING GAS LINE
TO BE REMOVED EXISTING GAS LINE
TO BE REMOVED
EXISTING GAS LINE
TO BE REMOVED
EXISTING GAS LINE
TO BE REMOVED
PROPOSED TRENCH DRAIN
(RE: PLUMBING)
PROPOSED TRENCH DRAIN
TRENCH BOTTOM SLOPE = 1% PROPOSED TRENCH DRAIN
TRENCH BOTTOM SLOPE = 1%
PROPOSED
OUTLET STRUCTURE
PROPOSED
GAS METERS
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / /
APPROXIMATE LOCATION
EXISTING WATER
SERVICE TO BE REMOVED
81.58 LF 12" PVC @ 0.28% 71.94 LF 12" PVC @ 0.28%
31.36 LF
8" PVC
@ 1.00%
PROPOSED DRAIN BASIN
(RE: PLUMBING)
PROPOSED DRAIN BASIN
(RE: PLUMBING)
SAND FILTER
APPROXIMATE
GAS SERVICE
LOCATION
APPROXIMATE
ELECTRIC SERVICE
LOCATION
NORTH
( IN FEET )
1 inch = ft.
20 0 20 Feet
20
40 60
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
C300
UTILITY PLAN
A. Reese
B. Ruch
1"=20'
No. Revisions:
By: Date:
REVIEWED BY:
N. Haws
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
Feb. 22, 2017
PROJECT:
1252-001
Sheet
of 17 Sheets
WEST PLUM HOUSING
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
02/22/17
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN
THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES
AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS
STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION.
3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE
SUBJECT TO CHANGE IN THE FIELD.
5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
8. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS
WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR
REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR
RESTORED TO CITY OR FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE
PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE
ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
9. REFER TO PLUMBING PLANS FOR ALL WATER SERVICE AND SANITARY SEWER SERVICE
LOCATIONS. IF CONFLICT OCCURS, BOTH THE PLUMBING ENGINEER AND CIVIL
ENGINEER SHALL BE CONTACTED PRIOR TO INSTALLATION OR ORDERING OF
MATERIALS.
10. ALL SANITARY SEWER SERVICE CONNECTION INVERTS AND LOCATIONS BASED ON
BEST AVAILABLE DATA. CONTRACTOR TO VERIFY LOCATION PRIOR TO CONSTRUCTION
AND NOTIFY ENGINEER OF ANY DISCREPANCIES.
11. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED
END SECTIONS.
12. ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443/C877
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). STORM DRAINS SHOWN ON
THIS DRAWING AS POLYVINYL CHLORIDE (PVC) SHALL BE C-900 OR APPROVED EQUAL.
13. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND
POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND CITY SHALL BE NOTIFIED OF
ANY POTENTIAL CONFLICTS.
14. CONTRACTOR SHALL COORDINATE ANY NECESSARY TELEPHONE, CABLE, FIBER, GAS,
AND ELECTRIC LOWERINGS (OR RE-ROUTING) WITH THE RESPECTIVE UTILITY
PROVIDERS.
15. CONTRACTOR TO COORDINATE FINAL LOCATION OF ALL GAS AND ELECTRIC METERS
WITH ARCHITECT AND UTILITY PROVIDERS.
EXISTING WATER MAIN
LEGEND:
W
G
T
CTV
EXISTING STORM SEWER
EXISTING CABLE
EXISTING TELEPHONE
EXISTING GAS
PROPOSED SEWER SERVICE S
EXISTING SANITARY SEWER SS
PROPOSED CURB & GUTTER
PROPOSED WATER SERVICE
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT H Y
D
EASEMENT LINE
PROPERTY BOUNDARY
EXISTING LOTLINE
W
PROPOSED WATER MAIN
PROPOSED SANITARY SEWER
PROPOSED STORM SEWER
PROPOSED ELECTRIC TRANSFORMER
PROPOSED ELECTRIC E
EXISTING PAVEMENT TO BE REMOVED
PROPOSED FIRE DEPARTMENT CONNECTION FDC
TF
PROPOSED FIRE SERVICE F
EXISTING ELECTRIC E
X
X
X
X
X
FDC
FDC
PROPOSED 30"
VERITCAL CURB & GUTTER
THE LOFTS AT CAMPUS WEST
TOWN SQUARE
CONDOMINIUMS
CITY PARK CONDOMINIUMS
(BOOK 1291, PAGE 862)
THE DISTRICT AT CAMPUS WEST
(REC. NO. 20130032356)
EXISTING 30"
VERTICAL CURB & GUTTER
TIE TO EXISTING
SIDEWALK
EXISTING PAVEMENT
MARKINGS (TYP.)
PROPOSED 5'
WALK w/ PAN
PROPOSED
ACCESS RAMPS
5' UTILITY EASEMENT
44' -
40' -
\A1;40' {\fISOCPEUR|b0|i0|c186|p34;}-{\fISOCPEUR|b0|i0|c186|p34;}
PROPOSED
SAWCUT LINE
DETENTION VAULT
OPEN BOTTOM
UTILITY EASEMENT
ASPHALT
MILL LIMIT
ASPHALT
MILL LIMIT
MATCH EXISTING
N:127079.67
E:188201.29
TIE TO EXISTING
CURB & GUTTER
N:127163.49
E:188210.26
N:127182.65
E:188216.54
N:127069.63
E:188215.75
N:127062.74
E:188488.37
N:126964.51
E:188487.96
N:126964.67
E:188604.53
N:127177.22
E:188606.38
TIE TO EXISTING
CUB & GUTTER
N:127182.28
E:188611.47
PROPOSED
ACCESS RAMPS
R15'
PROPOSED 2'
CONCRETE CHASE
PROPOSED 6'
SIDEWALK
PROPOSED 7'
SIDEWALK PROPOSED 2'
CONCRETE CHASE
PROPOSED
CONCRETE DRIVEWAY
PROPOSED 2'
CONCRETE CHASE
PROPOSED 1'
CONCRETE CHASE
PROPOSED 1'
CONCRETE CHASE
PROPOSED 1'
CONCRETE CHASE
5' CURB TRANSITION
N:127182.86
E:188509.84 N:127181.98
E:188559.83
N:126974.98
E:188590.10
N:127156.05
E:188593.29
N:127161.56
E:188236.91
N:126976.58
E:188499.45
N:127080.94
E:188238.50
PLUM STREET
(ROW VARIES)
SAND FILTER
LINE TABLE
LINE
L1
L2
L3
L4
L5
L6
L8
LENGTH
5.14'
46.62'
15.05'
20.00'
14.95'
278.69'
6.45'
BEARING
S77°25'25.19"W
N88°59'31.80"W
N88°59'31.80"W
N88°59'31.80"W
N88°59'31.80"W
N88°59'31.80"W
S06°08'40.97"W
CURVE TABLE
CURVE
C1
DELTA
84°51'47"
RADIUS
20.00'
LENGTH
29.62'
BEARING
S48°34'35"W
CHORD
26.99'
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
C200
PAVING PLAN
HORIZONTAL CONTROL & A. Reese
B. Ruch
1"=20'
No. Revisions:
By: Date:
REVIEWED BY:
N. Haws
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
Feb. 22, 2017
PROJECT:
1252-001
Sheet
of 17 Sheets
WEST PLUM HOUSING
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
02/22/17
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
NORTH
( IN FEET )
1 inch = ft.
20 0 20 Feet
20
40 60
1. SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND
PAVEMENT SECTIONS.
2. PAVEMENT MARKINGS SHALL BE PER CITY STANDARDS AND PROJECT
SPECIFICATION MANUAL.
3. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
4. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION,
AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED
OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR
RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE
PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE
ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
5. ALL PUBLIC CONCRETE SIDEWALKS SHALL BE 6" THICK. ALLEY DRIVEWAY/SIDEWALK
CONCRETE SHALL BE 8" (MIN.) THICK. ACTUAL ALLEY CONCRETE THICKNESS SHALL
BE BASED ON FINAL PAVEMENT DESIGN.
6. REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION
RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.
7. DUE TO THE NUMBER OF PROPOSED STREET CUTS IN PLUM STREET, THE ENTIRE
SOUTH HALF SHALL BE MILLED AND OVERLAID PRIOR TO PROJECT COMPLETION.
PROPOSED VERTICAL CURB & GUTTER
ACCESS RAMP w/ TRUNCATED DOMES
EASEMENTS
PUBLIC CONCRETE FLATWORK
PROPERTY BOUNDARY
PROPOSED LOT LINE
PROPOSED EDGE OF PAVEMENT
ASPHALT MILL & OVERLAY
PRIVATE CONCRETE FLATWORK
ASPHALT PATCH
OHU
SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS SS
SS SS
W
W W W W W W
W
W
W
VAULT
ELEC
S
T FO
T
FO
ELEC
VAULT
ELEC W
W
ST
/ / / / / / / /
/ / / / / / / /
/ / / / / / / /
FO
X
X X
X
X
X
X
X
X
X
X
X
X
X
G
G G G
FO FO FO
W
W
W
VAULT
ELEC
S
S
VAULT
CABLE
H
Y
D
WV
WV
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
VAULT
ELEC FO
G
G G
W
E
E
G
E
VAULT
ELEC
T FO
E
E
E
CABLE
W
S
O
T T T T
T T
E E
E
X
X
X
E E
CTV
CTV
OHU
OHU OHU
OHU
CTV
X
X
X X
X
E
E
E
T
X
CTV
CTV
CTV
CTV CTV
FO FO FO
FO FO
FO
FO FO
E E
E E E
E E E
E
X X
X
X
E E
E E E
E E
E E
E E
E E E
E
E
E
CTV CTV CTV
CTV CTV CTV
CTV CTV CTV CTV
CTV CTV CTV
FO FO FO
FO FO FO
FO FO FO FO
FO FO FO
W W
W W
W
W
W
W W W W
W W
W W
W W W W
W
W W W
W
W W
G
G G
G G
G
G
G G
G
G
G G G
G
G G G
G
G G G
G
G G
G
G
G
E E
E E
SS SS SS
SS SS SS SS SS SS SS SS SS SS SS SS
S
W W
W
W
D D
D
SS SS
S
W
S
G G G G
E E E E E E E E E E E E
E E
E E E E E E E
UD UD UD UD UD UD
DS2 DS2
DS2
DS2
DS2
F F F F F
E E E
E
E E
E E E
E
E
E E E E
F F F
F
DS3 DS3
F
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / /
/ / / / / / / / / / / / / / / / / / / / / /
/ / / / / /
/ / / / / / / / / / / / / / / / /
/ / /
/ / / / / /
/ / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / /
/
/
/
/ / / /
/ / / / / / / / / / / / / / / / / / / / /
/ / / / / /
/ /
/ / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / /
/ / / / / /
/ /
/ / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / /
/ / / / / / / / /
/ / / / /
/ / /
/
/ /
/
/ / / / / /
/
/ /
/
/ / / / / /
/
/ /
/
/ / / / / /
/
/ / /
/
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / /
/ / / / /
/ / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / /
/ / / / / / / / /
/ / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / /
/ / / / /
THE LOFTS AT CAMPUS WEST
TOWN SQUARE
CONDOMINIUMS
CITY PARK CONDOMINIUMS
(BOOK 1291, PAGE 862)
THE DISTRICT AT CAMPUS WEST
(REC. NO. 20130032356)
/
/
/
/
/
/
/
/
/
/ /
/ / /
EXISTING 20"
WATER LINE EXISTING 12" PVC
SANITARY SEWER
EXISTING BUILDING
TO BE REMOVED
UNDER SEPARATE
DEMO PERMIT
EXISTING BUILDING
TO BE REMOVED
UNDER SEPARATE
DEMO PERMIT
EXISTING BUILDING
TO BE REMOVED
UNDER SEPARATE
DEMO PERMIT
EXISTING BUILDING
TO BE REMOVED
UNDER SEPARATE
DEMO PERMIT
EXISTING BUILDING
TO BE REMOVED
UNDER SEPARATE
DEMO PERMIT
EXISTING BUILDING
TO BE REMOVED
UNDER SEPARATE
DEMO PERMIT
EXISTING BUILDING
TO BE REMOVED
UNDER SEPARATE
DEMO PERMIT
EXISTING BUILDING
TO BE REMOVED
EXISTING BUILDING
TO BE REMOVED
EXISTING TREE
TO BE REMOVED (TYP.)
EXISTING TREE
TO BE REMOVED (TYP.)
EXISTING GAS LINE
TO BE REMOVED EXISTING GAS LINE
TO BE REMOVED
EXISTING GAS LINE
TO BE REMOVED
EXISTING GAS LINE
TO BE REMOVED
EXISTING UTILITIES
TO BE REMOVED
EXISTING UTILITIES
TO BE REMOVED EXISTING UTILITIES
TO BE REMOVED
EXISTING UTILITIES
TO BE REMOVED
EXISTING UTILITIES
TO BE REMOVED
EXISTING GRAVEL DRIVE
TO BE REMOVED
EXISTING
GRAVEL DRIVE
TO BE REMOVED
EXISTING
GRAVEL DRIVE
TO BE REMOVED
EXISTING
GRAVEL DRIVE
TO BE REMOVED
EXISTING
GRAVEL DRIVE
TO BE REMOVED
EXISTING CURB
AND GUTTER
EXISTING 4' SIDEWALK
TO BE REMOVED
EXISTING 4' SIDEWALK
TO BE REMOVED
APPROXIMATE
FULL DEPTH
REMOVAL LIMIT
APPROXIMATE
FULL DEPTH
REMOVAL
LIMIT
EXISTING CURB & GUTTER
TO BE REMOVED
PAVEMENT
REMOVAL AREA
PLUM STREET
(ROW VARIES)
CITY PARK AVENUE
EXISTING TREE
TO BE REMAIN
EXISTING FENCE
TO BE REMOVED
EXISTING FENCE
TO BE REMOVED EXISTING FENCE
TO BE REMOVED
EXISTING FENCE
TO BE REMOVED
EXISTING FENCE
TO BE REMOVED
EXISTING FENCE
TO BE REMOVED
EXISTING FENCE
TO BE REMOVED
EXISTING
WATER SPIGOT
TO BE REMOVED
±40' -
44' -
EXISTING FENCE
TO BE REMOVED
EXISTING FH
EXISTING FH
EXISTING CABLE VAULT
TO BE RELOCATED
EXISTING FH
EXISTING LIGHT
TO BE RELOCATED
/ / / / / /
/ / /
/ / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / /
/
/ / / / / /
/ / / / / / / / /
/ / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / /
/ / / / / / / / / / /
/ / / / / / / / / / /
/ / / / / /
/
/ / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / /
/ /
/ / /
EXISTING WATER
SERVICE TO BE
ABANDONED AT MAIN
EXISTING WATER
SERVICE TO BE
ABANDONED AT MAIN
EXISTING WATER
SERVICE TO BE
ABANDONED AT MAIN
EXISTING WATER
SERVICE TO BE
ABANDONED AT MAIN
EXISTING EDGE
OF ASPHALT
EXISTING EDGE
OF ASPHALT
W W
W
W W
W
W W
W
/ / / / / / / / /
/
/
/
/
/
/
/ / / / / / / / / / / / / / / / / / / /
/
/
/
/ / / / / / / / / / / / /
/ / / / / / / / / / /
/
/
/ / / / / / / / /
/
/ / / / / / / / / / /
APPROXIMATE LOCATION
EXISTING WATER
SERVICE TO BE
ABANDONED AT MAIN
APPROXIMATE LOCATION
EXISTING WATER
SERVICE TO BE
ABANDONED AT MAIN
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / /
APPROXIMATE LOCATION
EXISTING WATER
SERVICE TO BE
ABANDONED AT MAIN
APPROXIMATE
MILL LIMIT
APPROXIMATE
MILL LIMIT APPROXIMATE
FULL DEPTH
REMOVAL
LIMIT
APPROXIMATE
MILL LIMIT
PAVEMENT
MILL AREA
PAVEMENT
MILL AREA
N:127182.65
E:188216.54
N:127177.22
E:188606.38
N:126964.67
E:188604.53
N:126964.51
E:188487.96
N:127062.74
E:188488.37
N:127069.63
E:188215.75
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
C100
& DEMOLITION PLAN
EXISTING CONDITIONS A. Reese
B. Ruch
1"=20'
No. Revisions:
By: Date:
REVIEWED BY:
N. Haws
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
Feb. 22, 2017
PROJECT:
1252-001
Sheet
of 17 Sheets
WEST PLUM HOUSING
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
02/22/17
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
NORTH
LEGEND:
EXISTING STORM SEWER
EXISTING VALVE
EXISTING TELEPHONE PEDESTAL
EXISTING TREES (TO REMAIN)
FIELD SURVEY BY:
EXISTING SANITARY SEWER SS
EXISTING WATER W
EXISTING FENCE X
EXISTING WATER METER
EXISTING FIRE HYDRANT
EXISTING ELECTRIC VAULT
PROPERTY BOUNDARY
EXISTING RIGHT-OF-WAY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
5015
5013
H Y
EXISTING TREES (TO BE REMOVED)
EXISTING PAVEMENT TO BE MILLED AND OVERLAID
1. ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER
ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL.
2. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A
FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE
DISTURBANCE.
3. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY
STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A
CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE.
4. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED
EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN
HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF
(½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF
EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE.
5. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING
OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS,
OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF
A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES.
6. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE.
7. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR
LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF,"
RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION
(G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50)
FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF
SUCH AREAS BEING CLEARED.
8. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING
EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT
SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE
AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM
TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW:
9. NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1-JULY 31)
WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING
SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. IF ACTIVE NESTS ARE FOUND,
THE CITY ENVIRONMENTAL PLANNER WILL DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE
REMOVAL AND CONSTRUCTION APPLY.
10. REFER TO LANDSCAPE AND IRRIGATION PLANS FOR ADDITIONAL TREE PROTECTION MEASURES.
TREE PROTECTION NOTES:
SUBSURFACE EXPLORATION BY:
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL,
REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL.
3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT
MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES
APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE,
ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT
COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL
ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS
RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD
AND CAN BE REACHED AT (970) 482-1249.
4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.
5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING
SITE SURVEY.
6. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
7. ADDITIONAL TREES NOT SHOWN ON THESE PLANS MAY EXIST AND MAY REQUIRE
REMOVAL. COORDINATION OF WHICH TREES ARE TO REMAIN AND WHICH ARE TO BE
REMOVED SHOULD BE COORDINATED WITH THE CITY FORESTER. REFER TO
LANDSCAPE PLANS AND TREE MITIGATION PLAN FOR ADDITIONAL INFORMATION.
8. CONTRACTOR SHALL COORDINATE WITH FORT COLLINS UTILITY FIELD OPERATIONS
DEPARTMENT AT (970) 221-6700 FOR WATER AND SEWER SERVICE ABANDONMENT.
9. NO DEMOLITION MAY OCCUR ONSITE UNTIL THE APPROPRIATE PERMITS AND
APPROVALS HAVE BEEN ISSUED BY THE CITY. THIS INCLUDES, BUT IS NOT LIMITED,
TO THE DEMOLITION OF STRUCTURES AND THE REMOVAL OF TREES.
TREE DIAMETER AT BREAST
HEIGHT (INCHES)
AUGER DISTANCE FROM
FACE OF TREE (FEET)
0-2 1
3-4 2
5-9 5
10-14 10
15-19 12
OVER 19 15
VAULT
ELEC
( IN FEET )
1 inch = ft.
20 0 20 Feet
20
40 60
NORTHERN ENGINEERING
PROJECT NO. 1252-001
DATE: JUNE 2016
TERRACON CONSULTANTS, INC.
GEOTECHNICAL ENGINEERING REPORT
PLUM STREET PROJECT
1303 AND 1307 WEST PLUM STREET
FORT COLLINS, COLORADO
TERRACON PROJECT NO. 20165035
DATE: MAY 19, 2016
EXISTING PAVEMENT TO BE REMOVED
T
WV
W
NOTE:
EXISTING INFORMATION SHOWN ON THIS PLAN IS BASED ON
FIELD SURVEY DATA COLLECTED IN JUNE 2016. CURRENT
FIELD CONDITIONS MAY VARY FROM WHAT IS SHOWN.
sewer should be constructed prior to installation of the water lines and dry utilities.
13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water
Utility.
14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is
discharged into a storm sewer, channel, irrigation ditch or any waters of the United States.
15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of
Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan.
16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite
drainage facilities shall be the responsibility of the property owner(s).
17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be
submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two
weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the
Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the
Development Agreement.
18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage,
whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the
City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development.
19. All recommendations of the Final Drainage Report for West Plum Housing, dated February 22, 2017 by Northern Engineering shall be followed and
implemented.
20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be
maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping.
21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must
be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by
the the City of Fort Collins street inspector.
22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit
is obtained, if applicable.
23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The
Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort
Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If
the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work
in the Engineer absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an
improper installation.
24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is
complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the
results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may
use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be
prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement
of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final
report.
25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at
all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to
the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then
resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets.
26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the
purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the
property lines and marked so as to reduce the excavation necessary for building connections.
27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for
roads within these districts.
28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the
Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval.
29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree
removal requiring a permit.
30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security.
Refer to OSHA Publication 2226, Excavating and Trenching.
31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The City of
Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall
be responsible for providing any and all traffic control devices as may be required by th e construction activities.
32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic
Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic
sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed.
33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's
local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and
from the Development.
34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site
construction activities on Sundays or holidays, unless there is prior written approval by City of Fort Collins.
35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these
drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise.
36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for
clarification, and annotate the dimension on the as-built record drawings.
37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and
specifications, and a copy of any permits and extension agreements needed for the job.
38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications,
the Developer shall contact the Designer and the City of Fort Collins Engineer immediately.
39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the
Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins
Engineer.
40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as
the basis of bearings. The information shall be as follows:
PROJECT DATUM: NAVD88
City of Fort Collins Benchmark 19-97
At the Southeast corner of West Elizabeth and Shields St., on a concrete traffic signal base.
ELEV.=5025.74
City of Fort Collins Benchmark 3-08
Southwest corner of Mulberry St. and Shields St. on a concrete traffic signal base.
ELEV.=5030.29
Please Note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted for their vertical
datums.
If NGVD29 Unadjusted Datum is required for any purpose, the following equation should be used:
NGVD29 Unadjusted = NAVD88 - 3.17'
Basis of Bearings
The Basis of Bearings is the South line of the Northeast Quarter of Section 15, as bearing South 89°04'20" East.
41. All stationing is based on centerline of roadways unless otherwise noted.
42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters,
landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like
kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the
issuance of the first Certificate of Occupancy.
43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing
street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in
accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large
patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width,
including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer
and/or the City of Fort Collins Inspector at the time the cuts are made.
44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before
construction, or to the grades and condition as required by these plans.
45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections.
46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and
workmanship defects for a minimum period of two years from the date of acceptance.
47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage
structures and pipes, for the following private streets: N.A.
48. Approved Variances are listed as follows:
a. Driveway Spacing
CONSTRUCTION NOTES
A. Grading and Erosion Control Notes
1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site.
2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans.
3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All
other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project
schedule, construction plans, and erosion control report.
4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property
sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion
control facilities shown herein.
5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the
area(s) required for immediate construction operations, and for the shortest practical period of time.
6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition
by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside
project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent
erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County.
7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall:
a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in
order to ensure the continued performance of their intended function.
b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector.
c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector.
8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and
debris from all drainage infrastructure and other public facilities.
9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of
way, and make sure streets and walkways are cleaned at the end of each working day.
10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to
cause their release into any waters of the United States.
11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering,
and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched.
12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and
before turning the maintenance over to the City/County or Homeowners Association (HOA).
13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant
or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout,
chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the
proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations.
14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and
located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout
material will be removed and properly disposed of prior to the area being restored.
15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever
measures are determined necessary, as directed by the City.
16. For additional information see separate Stormwater Management Plan / Erosion Control Report for West Plum Housing.
B. Street Improvement Notes
1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here.
2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval,
prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall
be submitted for approval prior to placement of any asphalt.
3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to
create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can
be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins.
4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the
subgrade has been inspected and approved by the City of Fort Collins Engineer.
5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings
are not allowed.
6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing
street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter
25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay
shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not
cut the new asphalt overlay work.
7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as
per the Right-of-Way Work Permit traffic control plan.
8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt.
Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly.
9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full
depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required.
The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single
axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than
3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins
Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be
notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector.
C. Traffic Signing and Pavement Marking Construction Notes
1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction
Notes listed here.
2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic.
3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD.
4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads.
5. All lane lines for concrete pavement should be epoxy paint.
6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement
of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols.
7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards.
8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction.
9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings.
10. All sign posts shall utilize break-away assemblies and fasteners per the Standards.
11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified
during the field inspection must be corrected before the 2-year warranty period will begin.
12. The Developer installing signs shall be responsible for locating and protecting all underground utilities.
13. Special care shall be taken in sign location to ensure an unobstructed view of each sign.
14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort
Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an
unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the
requirements of the 2-year warranty period for new construction (except fair wear on traffic markings).
15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail.
D. Storm Drainage Notes
1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite
drainage facilities shall be the responsibility of the property owner(s).
2. All recommendations of the Final Drainage Report for West Plum Housing, dated February 22, 2017 by Northern Engineering shall be followed and
implemented.
3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by
submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two
weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the
Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the
Development Agreement.
E. Utility Notes
1. All waterline and sanitary sewer construction shall conform to the City of Fort Collins Utility standards and specifications current to date of
construction.
2. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water
utility.
3. Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire.
4. HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The
HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections. Tracer wire shall be
installed with the HDPE service, and shall extend up the curb stop. The curb stop shall be covered with a metal valve box and "water" lid per City
Water Detail 11A.
C002
GENERAL & CONSTRUCTION NOTES
A. Reese
B. Ruch
NTS
No. Revisions:
By: Date:
REVIEWED BY:
N. Haws
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
Feb. 22, 2017
PROJECT:
1252-001
Sheet
of 17 Sheets
WEST PLUM HOUSING
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
02/22/17
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
By: Date:
REVIEWED BY:
N. Haws
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
Feb. 22, 2017
PROJECT:
1252-001
Sheet
of 17 Sheets
WEST PLUM HOUSING
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
02/22/17
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
FEBRUARY 2017
I hereby affirm that these final
construction plans were prepared
under my direct supervision, in
accordance with all applicable City
of Fort Collins and State of
Colorado standards and statutes,
respectively; and that I am fully
responsible for the accuracy of all
design. revisions, and record
conditions that I have noted on
these plans.
These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility
by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness
of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities
required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort
Collins for additional quantities of items shown that may be required during the construction phase.
DISCLAIMER STATEMENT:
CERTIFICATION STATEMENT:
VICINITY MAP
NORTH 1"=1500'
PROJECT DATUM: NAVD88
City of Fort Collins Benchmark 19-97
At the Southeast corner of West Elizabeth and Shields St., on a concrete traffic signal base.
ELEV.= 5025.74
City of Fort Collins Benchmark 3-08
Southwest corner of Mulberry St. and Shields St. on a concrete traffic signal base.
ELEV.= 5030.29
Please Note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used
NGVD29 Unadjusted for their vertical datums.
If NGVD29 Unadjusted Datum is required for any purpose, the following equation should be used:
NGVD29 Unadjusted = NAVD88 - 3.17'
Basis of Bearings
The Basis of Bearings is the South line of the Northeast Quarter of Section 15, as bearing South
89°04'20" East.
Northern Engineering
Project No. 1252-001
Date: June 2016
ORIGINAL FIELD SURVEY BY:
PROJECT BENCHMARKS:
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
A TRACT OF LAND LOCATED IN THE NORTHEAST QUARTER OF SECTION 15, TOWNSHIP 7 NORTH,
RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO
OWNER/APPLICANT
PROJECT TEAM:
SITE ENGINEER
Northern Engineering Services, Inc.
Nick Haws, PE, LEED AP
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
(970) 221-4158
SURVEYOR
ARCHITECT
CONTACT INFORMATION
PROJECT TEAM:
SHEET INDEX
E N G I N E E R I N G
N O R T H E RN
FINAL UTILITY PLANS FOR
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
UTILITY CONTACT LIST: *
UTILITY COMPANY
* This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for
the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for
locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of
Colorado (UNCC) at 811 for additional information.
PHONE NUMBER
GAS----------------- Xcel Energy----------------------------- Pat Kreager (970) 225-7840
ELECTRIC-------- City of Fort Collins Light & Power-- Luke Unruh (970) 416-2724
CABLE------------- Comcast---------------------------------- Don Kapperman (970) 567-0425
TELECOM.--------CenturyLink------------------------------- William Johnson (970) 377-6401
WATER------------ City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339
WASTEWATER--City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339
STORMWATER- City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339
LANDSCAPE ARCHITECT
GEOTECH
PROJECT
LOCATION
WEST PLUM HOUSING
Humphreys & Partners Architects, L.P.
Yaohua Yu
5339 Alpha Road, Suite 300
Dallas, Texas 75240
(972) 701-9636
Ripley Design, Inc.
Stephanie Van Dyken, PLA, APA
419 Canyon Avenue, Suite 200
Fort Collins, Colorado 80513
(970) 224-5828
Northern Engineering Services, Inc.
Bob Tessely, PLS
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
(970) 221-4158
E N G I N E E R I N G
N O R T H E RN
Terracon Consultants, Inc.
Kurt A. Stauder, P.G.
1901 Sharp Point Drive, Suite C
Fort Collins, CO 80525
(970) 484-0359
C001
COVER SHEET
A. Reese
B. Ruch
NTS
C001 COVER SHEET
Terracon Consultants, Inc.
Geotechnical Engineering Report
Plum Street Project
1303 and 1307 West Plum Street
Fort Collins, Colorado
Terracon Project No. 20165035
Date: May 19, 2016
SUBSURFACE EXPLORATION BY:
C002 GENERAL & CONSTRUCTION NOTES
S. SHIELDS ST.
W. MULBERRY ST.
W. ELIZABETH ST.
CSU
W. PLUM ST.
W. LAUREL ST.
CITY PARK AVE.
■ land planning ■ landscape architecture ■
■ urban design ■ entitlement ■
C100 EXISTING CONDITIONS & DEMOLITION PLAN
C200 HORIZONTAL CONTROL & PAVING PLAN
C300 UTILITY PLAN
C400 GRADING PLAN
C600-C601 UTILITY DETAILS
Plum Owner Ft Collins CO LLC
999 South Shady Grove Road, Suite 600
Memphis, TN 38120
(901) 259-2500
C602 STORMWATER DETAILS
TYPICAL SECTIONS
C301 DETENTION OUTFALL PLAN & PROFILE
C603 SITE DETAILS
C700 EROSION CONTROL PLAN
C701 EROSION CONTROL DETAILS
C800 DRAINAGE EXHIBIT
C500 WEST PLUM STREET PLAN & PROFILE
C401 COURTYARD GRADING PLAN
C402 GARAGE GRADING PLAN