Loading...
HomeMy WebLinkAboutTHORELL PARK SUBDIVISION (FORMERLY JOHNSTON ANNEXATION) - PDP - PDP160032 - REPORTS - DRAINAGE REPORT (7)153 154 156 158 157 159 160 161 162 139 140 141 142 143 46 47 48 49 50 51 52 53 54 55 45 44 43 42 41 155 153 154 156 158 157 159 160 161 162 139 140 141 142 143 46 47 48 49 50 51 52 53 54 55 45 44 43 42 41 155 EX. PRAIRIE HILL DRIVE STEPHEN DRIVE JUNIOR DRIVE (20' PRIVATE DRIVE) CRANSTON DRIVE (20' PRIVATE DRIVE) PETER DRIVE (20' PRIVATE DRIVE) EX. RED WILLOW DRIVE (76' ROW) DETENTION POND STORM-A PROFILE HORIZ. SCALE: 1" = 50' VERT. SCALE: 1" = 5' 4925 4930 4935 4940 4945 4950 4955 4960 4965 4925 4930 4935 69 70 68 71 72 73 74 22 23 24 25 26 28 27 98 96 97 69 70 68 71 72 73 74 22 23 24 25 26 28 27 98 96 97 JESSIE DRIVE (20' PRIVATE DRIVE) JUNIOR DRIVE (20' PRIVATE DRIVE) STORM C PROFILE HORIZ. SCALE: 1" = 50' VERT. SCALE: 1" = 5' 4935 4940 4945 4950 4935 4940 4945 4950 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 18" RCP ~ L=102.2' @ 3.77% 2-18" RCP ~ L=107.3' @ 0.51% 3-30" RCP ~ L=40.5' @ 0.49% 3-19" x 30" ECP ~ L=20.1' @ 0.50% 33 34 35 36 37 38 39 40 41 42 43 44 45 33 34 35 38 39 40 41 42 43 44 45 PRAIRIE HILL DRIVE STORM B PROFILE HORIZ. SCALE: 1" = 50' VERT. SCALE: 1" = 5' 132 131 130 129 145 146 147 148 125 126 127 109 128 110 111 112 89 105 106 107 108 90 91 92 132 131 130 129 145 146 147 148 125 126 127 109 128 110 111 112 89 105 106 107 108 90 91 92 ROSEN DRIVE JESSIE DRIVE (20' PRIVATE DRIVE) McKUSKY (20' PRIVATE DRIVE) CRANSTON DRIVE (20' PRIVATE DRIVE) DETENTION POND 36" RCP ~ 17.6 LF 36" RCP ~ 128.2 LF 30" RCP ~ 97.5 LF 30" RCP ~ 14.4 LF 24" RCP ~ 103.0 LF 18" RCP ~ 100.0 LF 18" RCP ~ 100.5 LF 18" RCP ~ 14.4 LF STORM D PROFILE 2 3 4 5 6 7 8 9 81 82 83 84 85 86 87 88 89 93 90 91 92 94 95 96 2 3 4 5 6 7 8 9 81 82 83 84 85 86 87 88 89 93 90 91 92 94 95 96 ROSEN DRIVE SHAW DRIVE DETENTION POND WEST STORM G PROFILE HORIZ. SCALE: 1" = 50 VERT. SCALE: 1" = 5' 4930 4935 4940 4945 4950 4930 4935 4940 4945 4950 TYPE 'L' RIPRAP L=5', W=5', d=18" 6" TYPE II BEDDING STORM F PROFILE HORIZ. SCALE: 1" = 50 VERT. SCALE: 1" = 5' 4935 4940 4945 4950 4955 4960 4935 4940 4945 4950 4955 4960 THORELL PARK COUNTY OF LARIMER FT. COLLINS, COLORADO PRELIMINARY DEVELOPMENT PLAN THESE PLANS HAVE BEEN REVIEWED BY THE LOCAL ENTITY FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY FOR BY THE REVIEWING DEPARTMENT, THE LOCAL ENTITY ENGINEER, OR THE LOCAL ENTITY FOR ACCURACY AND CORRECTNESS OF THE CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT QUANTITIES OF ITEMS ON THESE PLANS ARE THE FINAL QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS TO ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE LOCAL ENTITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE CONSTRUCTION PHASE. City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: City Engineer Date Water & Wastewater Utility Date Stormwater Utility Parks & Recreation Traffic Engineer Environmental Planner Date Date Date Date 1. PIPES SHALL HAVE A PRESSURE SEAL. RCP JOINT SEALS SHALL COMPLY WITH ASTM C-443. 2. ALL STORM SEWER SHALL BE CLASS III RCP WITH WATER TIGHT JOINTS. 3. ALL COORDINATES GIVEN FOR STORM SEWER INLETS ARE TO THE INTERSECTION OF THE MIDPOINT OF THE INLET AND FLOWLINE OF THE STREET. ALL OTHER COORDINATES FOR STORM SEWER STRUCTURES ARE TO END OF PIPE OR CENTER OF MANHOLE. ALL LENGTHS OF STORM SEWER PIPE ARE FROM THE CENTER OF MANHOLE OR INSIDE FACE OF THE INLET/STRUCTURE TO THE END OF PIPE. ALL SPECIALLY FABRICATED ACCESS STRUCTURES SHALL PROVIDE A CONTINUOUS VERTICAL ACCESS AT ONE SIDE OF THE PIPE SECTION. SHOP DRAWINGS OF SPECIALLY FABRICATED ACCESS STRUCTURE MUST BE SUBMITTED TO THE ENGINEER AND TO THE LARIMER COUNTY ENGINEERING DEPARTMENT FOR APPROVAL AT LEAST TWO WEEKS PRIOR TO CONSTRUCTION. 4. IFOB = INSIDE FACE OF BOX. NOTES: STORM SEWER - F & G PLAN & PROFILES STORM - F AND OUTFALL WITH SWALE PLAN VIEW SCALE: 1" = 50' OUTFALL SWALE - SECTION A-A NO SCALE 2' 2' CL SWALE 3' 3' 4:1 4:1 4:1 4:1 MATCH EXISTING GROUND MATCH EXISTING GROUND HYDRAULIC GRADE LINE = HORIZ. SCALE: 1" = 50' VERT. SCALE: 1" = 5' 4930 4935 4940 4945 4950 4955 4960 4965 4970 4930 4935 4940 4945 4950 4955 4960 4965 4970 L=119.3' @ 0.50% 36" RCP L=98.7' @ 0.50% 36" RCP L=14.4' @ 0.49% 30" RCP L=101.8' @ 0.50% 24" RCP L=100.0' @ 0.50% 18" RCP L=14.4' @ 0.49% 18" RCP L=100.5' @ 0.40% 15" RCP L=12.1' @ 0.50% 36" RCP STORM E PROFILE HORIZ. SCALE: 1" = 50' VERT. SCALE: 1" = 5' 4935 4940 4945 4950 4955 4960 4965 4970 4935 4940 4945 4950 4955 4960 4965 4970 L=12.1' @ 0.50% 36" RCP L=119.3' @ 0.50% 36" RCP L=98.7' @ 0.50% 36" RCP L=14.4' @ 0.49% 30" RCP L=101.8' @ 0.50% 24" RCP L=100.0' @ 0.50% 18" RCP 18" RCP ~ 14.4 LF L=100.5' @ 0.40% 15" RCP 138 137 136 139 140 141 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 119 120 116 121 117 98 99 118 100 96 101 97 138 137 136 139 140 141 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 119 120 116 121 117 98 99 118 100 96 101 97 STEPHEN DRIVE JESSIE DRIVE (20' PRIVATE DRIVE) McKUSKY (20' PRIVATE DRIVE) CRANSTON DRIVE (20' PRIVATE DRIVE) DETENTION POND 36" RCP ~ 119.3 LF 36" RCP ~ 12.1 LF 36" RCP ~ 98.7 LF 30" RCP ~ 14.4 LF 24" RCP ~ 101.8 LF 18" RCP ~ 100.0 LF 18" RCP ~ 14.4 LF 15" RCP ~ 100.5 LF THORELL PARK COUNTY OF LARIMER FT. COLLINS, COLORADO PRELIMINARY DEVELOPMENT PLAN THESE PLANS HAVE BEEN REVIEWED BY THE LOCAL ENTITY FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY FOR BY THE REVIEWING DEPARTMENT, THE LOCAL ENTITY ENGINEER, OR THE LOCAL ENTITY FOR ACCURACY AND CORRECTNESS OF THE CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT QUANTITIES OF ITEMS ON THESE PLANS ARE THE FINAL QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS TO ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE LOCAL ENTITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE CONSTRUCTION PHASE. City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: City Engineer Date Water & Wastewater Utility Date Stormwater Utility Parks & Recreation Traffic Engineer Environmental Planner Date Date Date Date 1. PIPES SHALL HAVE A PRESSURE SEAL. RCP JOINT SEALS SHALL COMPLY WITH ASTM C-443. 2. ALL STORM SEWER SHALL BE CLASS III RCP WITH WATER TIGHT JOINTS. 3. ALL COORDINATES GIVEN FOR STORM SEWER INLETS ARE TO THE INTERSECTION OF THE MIDPOINT OF THE INLET AND FLOWLINE OF THE STREET. ALL OTHER COORDINATES FOR STORM SEWER STRUCTURES ARE TO END OF PIPE OR CENTER OF MANHOLE. ALL LENGTHS OF STORM SEWER PIPE ARE FROM THE CENTER OF MANHOLE OR INSIDE FACE OF THE INLET/STRUCTURE TO THE END OF PIPE. ALL SPECIALLY FABRICATED ACCESS STRUCTURES SHALL PROVIDE A CONTINUOUS VERTICAL ACCESS AT ONE SIDE OF THE PIPE SECTION. SHOP DRAWINGS OF SPECIALLY FABRICATED ACCESS STRUCTURE MUST BE SUBMITTED TO THE ENGINEER AND TO THE LARIMER COUNTY ENGINEERING DEPARTMENT FOR APPROVAL AT LEAST TWO WEEKS PRIOR TO CONSTRUCTION. 4. IFOB = INSIDE FACE OF BOX. NOTES: STORM SEWER - D & E PLAN & PROFILES STORM - D PLAN VIEW SCALE: 1" = 50' STORM - E PLAN VIEW SCALE: 1" = 50' HYDRAULIC GRADE LINE = 4935 4940 4945 4950 4955 4960 4935 4940 4945 4950 4955 4960 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 18" RCP ~ L=16.4' @ 0.61% 18" RCP ~ L=40.3' @ 0.50% 24" RCP ~ L=25.4' @ 0.51% 24" RCP ~ L=5.5' @ 0.55% 24" RCP ~ L=328.6' @ 0.50% THORELL PARK COUNTY OF LARIMER FT. COLLINS, COLORADO PRELIMINARY DEVELOPMENT PLAN THESE PLANS HAVE BEEN REVIEWED BY THE LOCAL ENTITY FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY FOR BY THE REVIEWING DEPARTMENT, THE LOCAL ENTITY ENGINEER, OR THE LOCAL ENTITY FOR ACCURACY AND CORRECTNESS OF THE CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT QUANTITIES OF ITEMS ON THESE PLANS ARE THE FINAL QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS TO ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE LOCAL ENTITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE CONSTRUCTION PHASE. City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: City Engineer Date Water & Wastewater Utility Date Stormwater Utility Parks & Recreation Traffic Engineer Environmental Planner Date Date Date Date STORM SEWER - B & C PLAN & PROFILES 1. PIPES SHALL HAVE A PRESSURE SEAL. RCP JOINT SEALS SHALL COMPLY WITH ASTM C-443. 2. ALL STORM SEWER SHALL BE CLASS III RCP WITH WATER TIGHT JOINTS. 3. ALL COORDINATES GIVEN FOR STORM SEWER INLETS ARE TO THE INTERSECTION OF THE MIDPOINT OF THE INLET AND FLOWLINE OF THE STREET. ALL OTHER COORDINATES FOR STORM SEWER STRUCTURES ARE TO END OF PIPE OR CENTER OF MANHOLE. ALL LENGTHS OF STORM SEWER PIPE ARE FROM THE CENTER OF MANHOLE OR INSIDE FACE OF THE INLET/STRUCTURE TO THE END OF PIPE. ALL SPECIALLY FABRICATED ACCESS STRUCTURES SHALL PROVIDE A CONTINUOUS VERTICAL ACCESS AT ONE SIDE OF THE PIPE SECTION. SHOP DRAWINGS OF SPECIALLY FABRICATED ACCESS STRUCTURE MUST BE SUBMITTED TO THE ENGINEER AND TO THE LARIMER COUNTY ENGINEERING DEPARTMENT FOR APPROVAL AT LEAST TWO WEEKS PRIOR TO CONSTRUCTION. 4. IFOB = INSIDE FACE OF BOX. NOTES: STORM - C PLAN VEIW SCALE: 1" = 20' STORM - B PLAN VEIW SCALE: 1" = 20' HYDRAULIC GRADE LINE = 4940 4945 4950 4955 4960 4965 STORM A-2 PROFILE HORIZ. SCALE: 1" = 50' VERT. SCALE: 1" = 5' 4935 4940 4945 4950 4955 4960 4965 4970 4975 4935 4940 4945 4950 4955 4960 4965 4970 4975 36" RCP ~ L=30.0' @ 0.50% STORM-A1 PROFILE HORIZ. SCALE: 1" = 50' VERT. SCALE: 1" = 5' 4930 4935 4940 4945 4950 4955 4960 4930 4935 4940 4945 4950 4955 4960 18" RCP ~ L=38.9' @ 1.30% TYPE 'L' RIPRAP L=14', W=9', d=18" 12" TYPE II BEDDING TYPE 'L' RIPRAP L=5', W=5', d=18" 6" TYPE II BEDDING 33" RCP ~ L=95.4' @ 0.50% 30" RCP ~ L=65.6' @ 0.50% 24" RCP ~ L=87.9' @ 0.50% 24" RCP ~ L=47.8' @ 0.50% 18" RCP ~ L=55.0' @ 0.50% 18" RCP ~ L=14.4' @ 0.50% 18" RCP ~ L=11.9' @ 0.50% 18" RCP ~ L=135.6' @ 0.50% STORM A-3 PROFILE HORIZ. SCALE: 1" = 50' VERT. SCALE: 1" = 5' 4935 4940 4945 4950 4955 4960 4965 4935 4940 4945 4950 4955 4960 4965 18" RCP ~ L=13.3' @ 0.50% STORM A-4 PROFILE HORIZ. SCALE: 1" = 50' VERT. SCALE: 1" = 5' 4935 4940 4945 4950 4955 4960 4965 4935 4940 4945 4950 4955 4960 4965 18" RCP ~ L=25.3' @ -0.50% STORM A-5 PROFILE HORIZ. SCALE: 1" = 50' VERT. SCALE: 1" = 5' 4930 4935 4940 4945 4950 4955 4960 4965 4930 4935 4940 4945 4950 4955 4960 4965 18" RCP ~ L=31.7' @ 0.49% THORELL PARK COUNTY OF LARIMER FT. COLLINS, COLORADO PRELIMINARY DEVELOPMENT PLAN THESE PLANS HAVE BEEN REVIEWED BY THE LOCAL ENTITY FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY FOR BY THE REVIEWING DEPARTMENT, THE LOCAL ENTITY ENGINEER, OR THE LOCAL ENTITY FOR ACCURACY AND CORRECTNESS OF THE CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT QUANTITIES OF ITEMS ON THESE PLANS ARE THE FINAL QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS TO ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE LOCAL ENTITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE CONSTRUCTION PHASE. City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: City Engineer Date Water & Wastewater Utility Date Stormwater Utility Parks & Recreation Traffic Engineer Environmental Planner Date Date Date Date STORM SEWER - A PLAN & PROFILES 1. PIPES SHALL HAVE A PRESSURE SEAL. RCP JOINT SEALS SHALL COMPLY WITH ASTM C-443. 2. ALL STORM SEWER SHALL BE CLASS III RCP WITH WATER TIGHT JOINTS. 3. ALL COORDINATES GIVEN FOR STORM SEWER INLETS ARE TO THE INTERSECTION OF THE MIDPOINT OF THE INLET AND FLOWLINE OF THE STREET. ALL OTHER COORDINATES FOR STORM SEWER STRUCTURES ARE TO END OF PIPE OR CENTER OF MANHOLE. ALL LENGTHS OF STORM SEWER PIPE ARE FROM THE CENTER OF MANHOLE OR INSIDE FACE OF THE INLET/STRUCTURE TO THE END OF PIPE. ALL SPECIALLY FABRICATED ACCESS STRUCTURES SHALL PROVIDE A CONTINUOUS VERTICAL ACCESS AT ONE SIDE OF THE PIPE SECTION. SHOP DRAWINGS OF SPECIALLY FABRICATED ACCESS STRUCTURE MUST BE SUBMITTED TO THE ENGINEER AND TO THE LARIMER COUNTY ENGINEERING DEPARTMENT FOR APPROVAL AT LEAST TWO WEEKS PRIOR TO CONSTRUCTION. 4. IFOB = INSIDE FACE OF BOX. NOTES: STORM - A THRU A1 PLAN SCALE: 1" = 50' HYDRAULIC GRADE LINE =