Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutWILMARC MEDICAL - PDP - PDP160033 - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTS (14)01 FLOOR
100'-0"
01 FLOOR
100'-0"
T.O.W. (A)
129'-0"
T.O.W. (A)
129'-0"
BRICK VENEER
MAS-01
TBD
METAL WALL PANEL
MW-01
"CHARCOAL"
BRICK VENEER
MAS-01
TBD
COMPOSITE METAL WALL PANEL
MW-02
"WHITE"
METAL WALL PANEL
MW-01
"CHARCOAL"
ALUMINUM
SUNSHADE
CHANGE IN WALL
PLANE (2'-8")
METAL WALL PANEL
MW-01
"CHARCOAL"
MAIN ENTRANCE
COMPOSITE METAL WALL PANEL
MW-02
"WHITE"
01 FLOOR
100'-0"
01 FLOOR
100'-0"
T.O.W. (A)
129'-0"
T.O.W. (A)
129'-0"
ALUMINUM SUNSHADE
OVERHEAD DOCK DOORS, TYPICAL
PROPOSED WASTE COMPACTOR
CHANGE IN WALL
PLANE (6'-0")
HEIGHT:WIDTH RATIO - 1.0 : 4.5
144'-0"
HEIGHT:WIDTH RATIO = 1.0 : 1.7
48'-0"
HEIGHT:WIDTH RATIO = 1.0 : 1.7
48'-0"
CHANGE IN WALL
PLANE (5'-4")
RAMP W/ FLUSH OVERHEAD DOOR
PRECAST/SITE CAST CONCRETE PANELS
PTE-03
TEX COTE COLORED FINISH "DOVE GREY"
PRECAST/SITE CAST CONCRETE PANELS
01 FLOOR
100'-0"
T.O.W. (A)
129'-0"
ALUMINUM SUNSHADE
PROJECTING FIN
BRICK VENEER
MAS-01
TBD
29'-0" 4'-0"
33'-0"
7'-1" 6'-11" 4'-0" 7'-0" 4'-0"
PRECAST/SITE CAST CONCRETE PANELS
PTE-03
TEX COTE COLORED FINISH "DOVE GREY"
PRECAST/SITE CAST CONCRETE PANELS
PTE-01
TEX COTE COLORED FINISH "CHARCOAL"
PRECAST/SITE CAST CONCRETE PANELS
PTE-02
TEX COTE COLORED FINISH "LINEN"
PRECAST/SITE CAST CONCRETE PANELS
PTE-03
TEX COTE COLORED FINISH "DOVE GREY"
01 FLOOR
100'-0"
T.O.W. (A)
129'-0"
T.O.W. (B)
127'-0"
CHANGE IN WALL
PLANE (6'-0")
HEIGHT:WIDTH RATIO = 1.0 : 1.7
48'-0"
PRECAST/SITE CAST CONCRETE PANELS
PTE-01
TEX COTE COLORED FINISH "CHARCOAL"
BRICK VENEER
MAS-01
TBD
27'-0" 2'-0"
6'-0" 8'-0" 4'-0" 9'-0"
29'-0"
PROJECT NO:
ISSUE AND REVISION SCHEDULE:
SEAL:
DRAWN BY:
CHECKED BY:
DATE: REVISION:
FILE:
DRAWN BY:
SHEET:
DRAWING TITLE:
PROJECT:
405 Mason Court, Suite 115 A
Fort Collins, CO 80524
Phone: (970) 482-8125
LOT 1, HARMONY TECHNOLOGY
PARK FIFTH FILING
C:\Local TAS Files\16-406 Wilmarc Medical_RVT2016_LOCAL (el).rvt
11/28/2016 8:32:29 AM B, PDP SUBMITTAL 2, 28 NOV 2016
PRELIMINARY
DEVELOPMENT
PLAN
16-406
TAS-EL
TAS-JE
TAS-EL
EL002
PANEL ELEVATIONS
AND 3D VIEWS
WILMARC
MEDICAL
EL002 1/8" = 1'-0"
1 BUILDING ELEVATION - PANEL TYPE "A"
EL002 1/8" = 1'-0"
2 BUILDING ELEVATION - PANEL TYPE "B"
EL002
3 3D VIEW
EL002
4 3D VIEW
EL002
5 3D VIEW
PDP SUBMITTAL 11 OCT 2016
PDP SUBMITTAL 2 28 NOV 2016
PTE-02
TEX COTE COLORED FINISH "LINEN"
PRECAST/SITE CAST CONCRETE PANELS
PTE-01
TEX COTE COLORED FINISH "CHARCOAL"
PRECAST/SITE CAST CONCRETE PANELS
PTE-01
TEX COTE COLORED FINISH "CHARCOAL"
PRECAST/SITE CAST CONCRETE PANELS
PTE-03
TEX COTE COLORED FINISH "DOVE GREY"
PRECAST/SITE CAST CONCRETE PANELS
PTE-01
TEX COTE COLORED FINISH "CHARCOAL"
MECHANICAL LOUVERS
01 FLOOR
100'-0"
01 FLOOR
100'-0"
T.O.W. (A)
129'-0"
T.O.W. (A)
129'-0"
4'-8"
EMPLOYEE AND WAREHOUSE ENTRANCE
CHANGE IN WALL
PLANE (11'-4")
HEIGHT:WIDTH RATIO = 1.0 : 2.7
90'-0"
PROPOSED BUILDING WALL
SIGN - APPROVED THROUGH
SEPARATE APPLICATION
METAL WALL PANEL
MW-01
"CHARCOAL"
BRICK VENEER
MAS-01
TBD
PRECAST/SITE CAST CONCRETE PANELS
PTE-01
TEX COTE COLORED FINISH "CHARCOAL"
PRECAST/SITE CAST CONCRETE PANELS
PTE-03
TEX COTE COLORED FINISH "DOVE GREY"
PRECAST/SITE CAST CONCRETE PANELS
PTE-02
TEX COTE COLORED FINISH "LINEN"
PRECAST/SITE CAST CONCRETE PANELS
PTE-01
TEX COTE COLORED FINISH "CHARCOAL"
PRECAST/SITE CAST CONCRETE PANELS
PTE-03
TEX COTE COLORED FINISH "DOVE GREY"
33'-0" MAX. HEIGHT
29'-0"
SITE WALL
01 FLOOR
100'-0"
01 FLOOR
100'-0"
T.O.W. (A)
129'-0"
T.O.W. (A)
129'-0"
BRICK VENEER
MAS-01
TBD
BRICK VENEER
MAS-01
TBD
ALUMINUM
SUNSHADE
METAL WALL PANEL
MW-01
"CHARCOAL"
OUTDOOR EMPLOYEE
BREAK AREA BEHIND
LOW SITE WALL
CURTAIN WALL
SYSTEM
COMPOSITE METAL WALL PANEL
MW-02
"WHITE"
COMPOSITE METAL WALL PANEL
MW-02
"WHITE"
01 FLOOR
100'-0"
01 FLOOR
100'-0"
T.O.W. (A)
129'-0"
T.O.W. (A)
129'-0"
ALUMINUM
SUNSHADE, TYPICAL
33'-0" MAX HEIGHT
27'-0" 2'-0"
29'-0"
HEIGHT:WIDTH RATIO = 1.0 : 2.7
96'-0"
CHANGE IN WALL
PLANE (6'-0")
CHANGE IN WALL
PLANE (6'-0")
PROJECTING FIN
PROJECTING FIN
HEIGHT:WIDTH RATIO = 1.0 : 2.7
96'-0"
HEIGHT:WIDTH RATIO = 1.0 : 2.7
96'-0"
HEIGHT:WIDTH RATIO = 1.0 : 1.7
48'-0"
HEIGHT:WIDTH RATIO = 1.0 : 1.7
48'-0"
4'-0" "TOP"
PRECAST/SITE CAST CONCRETE PANELS
PTE-02
TEX COTE COLORED FINISH "LINEN"
PRECAST/SITE CAST CONCRETE PANELS
PTE-01
TEX COTE COLORED FINISH "CHARCOAL"
BRICK VENEER
MAS-01
TBD
PRECAST/SITE CAST CONCRETE PANELS
PTE-02
TEX COTE COLORED FINISH "LINEN"
BRICK VENEER
MAS-01
TBD
METAL WALL PANEL
MW-01
"CHARCOAL"
PRECAST/SITE CAST CONCRETE PANELS
PTE-03
TEX COTE COLORED FINISH "DOVE GREY"
PRECAST/SITE CAST CONCRETE PANELS
PTE-01
PRECAST/SITE CAST CONCRETE PANELS TEX COTE COLORED FINISH "CHARCOAL"
PTE-03
TEX COTE COLORED FINISH "DOVE GREY"
TYP. WINDOW SPACING
24'-0"
PROJECT NO:
ISSUE AND REVISION SCHEDULE:
SEAL:
DRAWN BY:
CHECKED BY:
DATE: REVISION:
FILE:
DRAWN BY:
SHEET:
DRAWING TITLE:
PROJECT:
405 Mason Court, Suite 115 A
Fort Collins, CO 80524
Phone: (970) 482-8125
LOT 1, HARMONY TECHNOLOGY
PARK FIFTH FILING
C:\Local TAS Files\16-406 Wilmarc Medical_RVT2016_LOCAL (el).rvt
11/28/2016 8:31:48 AM B, PDP SUBMITTAL 2, 28 NOV 2016
PRELIMINARY
DEVELOPMENT
PLAN
16-406
TAS-EL
TAS-JE
TAS-EL
EL001
BUILDING ELEVATIONS
WILMARC
MEDICAL
EL001 1" = 20'-0"
5 BUILDING ELELVATION - SOUTHEAST (PZ)
EL001 1" = 20'-0"
3 BUILDING ELEVATION - EAST (PZ)
EL001 1" = 20'-0"
2 BUILDING ELEVATION - NORTH (PZ)
EL001 1" = 20'-0"
4 BUILDING ELEVATION - SOUTHWEST (PZ)
EL001 1" = 20'-0"
1 BUILDING ELEVATION - WEST (PZ)
PDP SUBMITTAL 11 OCT 2016
PDP SUBMITTAL 2 28 NOV 2016