Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WILMARC MEDICAL - PDP - PDP160033 - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTS (14)
01 FLOOR 100'-0" 01 FLOOR 100'-0" T.O.W. (A) 129'-0" T.O.W. (A) 129'-0" BRICK VENEER MAS-01 TBD METAL WALL PANEL MW-01 "CHARCOAL" BRICK VENEER MAS-01 TBD COMPOSITE METAL WALL PANEL MW-02 "WHITE" METAL WALL PANEL MW-01 "CHARCOAL" ALUMINUM SUNSHADE CHANGE IN WALL PLANE (2'-8") METAL WALL PANEL MW-01 "CHARCOAL" MAIN ENTRANCE COMPOSITE METAL WALL PANEL MW-02 "WHITE" 01 FLOOR 100'-0" 01 FLOOR 100'-0" T.O.W. (A) 129'-0" T.O.W. (A) 129'-0" ALUMINUM SUNSHADE OVERHEAD DOCK DOORS, TYPICAL PROPOSED WASTE COMPACTOR CHANGE IN WALL PLANE (6'-0") HEIGHT:WIDTH RATIO - 1.0 : 4.5 144'-0" HEIGHT:WIDTH RATIO = 1.0 : 1.7 48'-0" HEIGHT:WIDTH RATIO = 1.0 : 1.7 48'-0" CHANGE IN WALL PLANE (5'-4") RAMP W/ FLUSH OVERHEAD DOOR PRECAST/SITE CAST CONCRETE PANELS PTE-03 TEX COTE COLORED FINISH "DOVE GREY" PRECAST/SITE CAST CONCRETE PANELS 01 FLOOR 100'-0" T.O.W. (A) 129'-0" ALUMINUM SUNSHADE PROJECTING FIN BRICK VENEER MAS-01 TBD 29'-0" 4'-0" 33'-0" 7'-1" 6'-11" 4'-0" 7'-0" 4'-0" PRECAST/SITE CAST CONCRETE PANELS PTE-03 TEX COTE COLORED FINISH "DOVE GREY" PRECAST/SITE CAST CONCRETE PANELS PTE-01 TEX COTE COLORED FINISH "CHARCOAL" PRECAST/SITE CAST CONCRETE PANELS PTE-02 TEX COTE COLORED FINISH "LINEN" PRECAST/SITE CAST CONCRETE PANELS PTE-03 TEX COTE COLORED FINISH "DOVE GREY" 01 FLOOR 100'-0" T.O.W. (A) 129'-0" T.O.W. (B) 127'-0" CHANGE IN WALL PLANE (6'-0") HEIGHT:WIDTH RATIO = 1.0 : 1.7 48'-0" PRECAST/SITE CAST CONCRETE PANELS PTE-01 TEX COTE COLORED FINISH "CHARCOAL" BRICK VENEER MAS-01 TBD 27'-0" 2'-0" 6'-0" 8'-0" 4'-0" 9'-0" 29'-0" PROJECT NO: ISSUE AND REVISION SCHEDULE: SEAL: DRAWN BY: CHECKED BY: DATE: REVISION: FILE: DRAWN BY: SHEET: DRAWING TITLE: PROJECT: 405 Mason Court, Suite 115 A Fort Collins, CO 80524 Phone: (970) 482-8125 LOT 1, HARMONY TECHNOLOGY PARK FIFTH FILING C:\Local TAS Files\16-406 Wilmarc Medical_RVT2016_LOCAL (el).rvt 11/28/2016 8:32:29 AM B, PDP SUBMITTAL 2, 28 NOV 2016 PRELIMINARY DEVELOPMENT PLAN 16-406 TAS-EL TAS-JE TAS-EL EL002 PANEL ELEVATIONS AND 3D VIEWS WILMARC MEDICAL EL002 1/8" = 1'-0" 1 BUILDING ELEVATION - PANEL TYPE "A" EL002 1/8" = 1'-0" 2 BUILDING ELEVATION - PANEL TYPE "B" EL002 3 3D VIEW EL002 4 3D VIEW EL002 5 3D VIEW PDP SUBMITTAL 11 OCT 2016 PDP SUBMITTAL 2 28 NOV 2016 PTE-02 TEX COTE COLORED FINISH "LINEN" PRECAST/SITE CAST CONCRETE PANELS PTE-01 TEX COTE COLORED FINISH "CHARCOAL" PRECAST/SITE CAST CONCRETE PANELS PTE-01 TEX COTE COLORED FINISH "CHARCOAL" PRECAST/SITE CAST CONCRETE PANELS PTE-03 TEX COTE COLORED FINISH "DOVE GREY" PRECAST/SITE CAST CONCRETE PANELS PTE-01 TEX COTE COLORED FINISH "CHARCOAL" MECHANICAL LOUVERS 01 FLOOR 100'-0" 01 FLOOR 100'-0" T.O.W. (A) 129'-0" T.O.W. (A) 129'-0" 4'-8" EMPLOYEE AND WAREHOUSE ENTRANCE CHANGE IN WALL PLANE (11'-4") HEIGHT:WIDTH RATIO = 1.0 : 2.7 90'-0" PROPOSED BUILDING WALL SIGN - APPROVED THROUGH SEPARATE APPLICATION METAL WALL PANEL MW-01 "CHARCOAL" BRICK VENEER MAS-01 TBD PRECAST/SITE CAST CONCRETE PANELS PTE-01 TEX COTE COLORED FINISH "CHARCOAL" PRECAST/SITE CAST CONCRETE PANELS PTE-03 TEX COTE COLORED FINISH "DOVE GREY" PRECAST/SITE CAST CONCRETE PANELS PTE-02 TEX COTE COLORED FINISH "LINEN" PRECAST/SITE CAST CONCRETE PANELS PTE-01 TEX COTE COLORED FINISH "CHARCOAL" PRECAST/SITE CAST CONCRETE PANELS PTE-03 TEX COTE COLORED FINISH "DOVE GREY" 33'-0" MAX. HEIGHT 29'-0" SITE WALL 01 FLOOR 100'-0" 01 FLOOR 100'-0" T.O.W. (A) 129'-0" T.O.W. (A) 129'-0" BRICK VENEER MAS-01 TBD BRICK VENEER MAS-01 TBD ALUMINUM SUNSHADE METAL WALL PANEL MW-01 "CHARCOAL" OUTDOOR EMPLOYEE BREAK AREA BEHIND LOW SITE WALL CURTAIN WALL SYSTEM COMPOSITE METAL WALL PANEL MW-02 "WHITE" COMPOSITE METAL WALL PANEL MW-02 "WHITE" 01 FLOOR 100'-0" 01 FLOOR 100'-0" T.O.W. (A) 129'-0" T.O.W. (A) 129'-0" ALUMINUM SUNSHADE, TYPICAL 33'-0" MAX HEIGHT 27'-0" 2'-0" 29'-0" HEIGHT:WIDTH RATIO = 1.0 : 2.7 96'-0" CHANGE IN WALL PLANE (6'-0") CHANGE IN WALL PLANE (6'-0") PROJECTING FIN PROJECTING FIN HEIGHT:WIDTH RATIO = 1.0 : 2.7 96'-0" HEIGHT:WIDTH RATIO = 1.0 : 2.7 96'-0" HEIGHT:WIDTH RATIO = 1.0 : 1.7 48'-0" HEIGHT:WIDTH RATIO = 1.0 : 1.7 48'-0" 4'-0" "TOP" PRECAST/SITE CAST CONCRETE PANELS PTE-02 TEX COTE COLORED FINISH "LINEN" PRECAST/SITE CAST CONCRETE PANELS PTE-01 TEX COTE COLORED FINISH "CHARCOAL" BRICK VENEER MAS-01 TBD PRECAST/SITE CAST CONCRETE PANELS PTE-02 TEX COTE COLORED FINISH "LINEN" BRICK VENEER MAS-01 TBD METAL WALL PANEL MW-01 "CHARCOAL" PRECAST/SITE CAST CONCRETE PANELS PTE-03 TEX COTE COLORED FINISH "DOVE GREY" PRECAST/SITE CAST CONCRETE PANELS PTE-01 PRECAST/SITE CAST CONCRETE PANELS TEX COTE COLORED FINISH "CHARCOAL" PTE-03 TEX COTE COLORED FINISH "DOVE GREY" TYP. WINDOW SPACING 24'-0" PROJECT NO: ISSUE AND REVISION SCHEDULE: SEAL: DRAWN BY: CHECKED BY: DATE: REVISION: FILE: DRAWN BY: SHEET: DRAWING TITLE: PROJECT: 405 Mason Court, Suite 115 A Fort Collins, CO 80524 Phone: (970) 482-8125 LOT 1, HARMONY TECHNOLOGY PARK FIFTH FILING C:\Local TAS Files\16-406 Wilmarc Medical_RVT2016_LOCAL (el).rvt 11/28/2016 8:31:48 AM B, PDP SUBMITTAL 2, 28 NOV 2016 PRELIMINARY DEVELOPMENT PLAN 16-406 TAS-EL TAS-JE TAS-EL EL001 BUILDING ELEVATIONS WILMARC MEDICAL EL001 1" = 20'-0" 5 BUILDING ELELVATION - SOUTHEAST (PZ) EL001 1" = 20'-0" 3 BUILDING ELEVATION - EAST (PZ) EL001 1" = 20'-0" 2 BUILDING ELEVATION - NORTH (PZ) EL001 1" = 20'-0" 4 BUILDING ELEVATION - SOUTHWEST (PZ) EL001 1" = 20'-0" 1 BUILDING ELEVATION - WEST (PZ) PDP SUBMITTAL 11 OCT 2016 PDP SUBMITTAL 2 28 NOV 2016