HomeMy WebLinkAboutGATEWAY AT PROSPECT AMENDED ODP - ODP160001 - PLANS - UTILITY PLANSDRAWING FILENAME: D:\Projects\892-001\Dwg\ODP\892-001_MUP.dwg LAYOUT NAME: MUP DATE: Aug 11, 2016 - 3:20pm CAD OPERATOR: stephanie
LIST OF XREFS: [892-001_xEXST] [NES-xborder - ODP] [892-001_MUP_LEGEND] [892-001_xADJ_PARCELS] [892-001_xODP] [892-001_xUTIL-ODP] [892-001_xSITE_ROUNDABOUT] [892-001_State plane section
line] [02-Gateway at Propspect - SITE] [892-001_xSITE_INTERNAL]
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
N O R T H E RN
08/15/2016
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
www.northernengineering.com
Phone: 970.221.4158
W
LEGEND:
W
SS
SS
BL
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
R
( IN FEET )
0
1 INCH = 200 FEET
200 200 400 600
NOTES:
1. ALL WATER LINES TIE INTO ELCO WATER DISTRICT.
2. ALL SANITARY SEWER LINES TIE INTO BOXELDER SANITATION DISTRICT.
3. ALL STREET ALIGNMENTS AND PROPOSED UTILITIES SHOWN WITH THE
MASTER UTILITY PLAN ARE CONCEPTUAL IN NATURE AND ARE SUBJECT TO
CHANGE WITH SUBSEQUENT PROJECT DEVELOPMENT PLAN APPLICATIONS.
4. REFER TO GATEWAY AT PROSPECT ODP BY THE BIRDSALL GROUP FOR
ADDITIONAL INFORMATION.
5. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES
WITHIN THE NATURAL HABITAT BUFFER ZONES. 1
DRAWING FILENAME: D:\Projects\892-001\Dwg\ODP\892-001_MDP.dwg LAYOUT NAME: MDP DATE: Aug 11, 2016 - 3:24pm CAD OPERATOR: stephanie
LIST OF XREFS: [892-001_xEXST] [NES-xborder - ODP] [892-001_xADJ_PARCELS] [892-001_xTOPO] [892-001_MDP_LEGEND] [892-001_State plane section line] [892-001_xACE_IMPROVEMENTS] [892-001_xGRAD_ACE
CHANNEL] [892-001_xSITE_ROUNDABOUT] [892-001_xODP] [892-001_xSITE_INTERNAL] [02-Gateway at Propspect - SITE]
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
N O R T H E RN
08/15/2016
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
www.northernengineering.com
Phone: 970.221.4158
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
R
( IN FEET )
0
1 INCH = 200 FEET
200 200 400 600
2
LEGEND:
1
1.45 ac
XS#:
EBFE: ELEV
BL
PBFE: ELEV
NOTES:
1. ALL STREET ALIGNMENTS AND PROPOSED DRAINAGE IMPROVEMENTS SHOWN WITH
THE MASTER DRAINAGE PLAN ARE CONCEPTUAL IN NATURE AND ARE SUBJECT TO
CHANGE WITH SUBSEQUENT PROJECT DEVELOPMENT PLAN APPLICATIONS.
2. REFER TO GATEWAY AT PROSPECT ODP BY THE BIRDSALL GROUP FOR ADDITIONAL
INFORMATION.
3. FLOOD ZONE DESIGNATION: ACCORDING TO FEMA MAP NUMBER 08069C0984H,
DATED MAY 2, 2012, A PORTION OF THIS TRACT OF LAND IS WITHIN A FEMA
DESIGNATED SPECIAL FLOOD HAZARD AREA (SFHA), AND IS SUBJECT TO
INUNDATION BY THE 1% ANNUAL CHANCE (100-YEAR) FLOOD.
4. THE BOXELDER 6 CLOMR PREPARED FOR THE BOXELDER BASIN REGIONAL
STORMWATER AUTHORITY CAN BE REFERENCED BY FEMA CASE NUMBER
15-08-0329R. BUILDING AND CONSTRUCTION PERMITS MUST MEET THE FLOODPLAIN
REQUIREMENTS BASED ON THE REGULATORY FLOODPLAIN IN EFFECT AT THE TIME
OF PERMIT ISSUANCE. THE REVISED BOXELDER CREEK FLOODPLAIN WILL NOT BE
REGULATORY UNTIL THE LOMR IS APPROVED BY FEMA. FINAL FLOOD FRINGE AND
FLOODWAY BOUNDARIES MAY DIFFER FROM THOSE IN THE CLOMR.
5. REFER TO GATEWAY AT PROSPECT ODP DRAINAGE LETTER DATED MAY 3, 2016 FOR
MORE INFORMATION REGARDING THE MASTER DRAINAGE PLAN.
6. PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATORY 100-YR
BOXELDER CREEK FLOODWAY AND HIGH-RISK FLOOD FRINGE, AND MUST COMPLY
WITH THE FLOODPLAIN REQUIREMENTS OF CHAPTER 10 OF THE CITY OF FORT
COLLINS MUNICIPAL CODE.
7. CONSTRUCTION OF NEW RESIDENTIAL STRUCTURES IS NOT ALLOWED IN THE
FLOODWAY. RESIDENTIAL STRUCTURES ARE ALLOWED IN THE FLOOD FRINGE,
PROVIDED THAT ALL DUCT WORK, HEATING, VENTILATION AND AIR CONDITIONING
SYSTEMS, HOT WATER HEATER, ELECTRICAL AND THE LOWEST FLOOR OF THE
BUILDING ARE A MINIMUM OF 18-INCHES ABOVE THE BASE FLOOD ELEVATION (BFE).
THAT MINIMUM ELEVATION IS KNOWN AS THE REGULATORY FLOOD PROTECTION
ELEVATION (RFPE). RFPE=BFE+18".
8. BASEMENTS MAY NOT BE CONSTRUCTED BELOW THE RFPE IN THE FLOOD FRINGE.
CRAWL SPACES (IF USED RATHER THAN SLAB-ON-GRADE) MUST BE BUILT IN
CONFORMANCE WITH SECTION 10-40 OF CITY OF FORT COLLINS MUNICIPAL CODE
(THIS WILL INCLUDE VENTING, SUMP PUMPS, ETC.).
9. NONSTRUCTURAL DEVELOPMENT (FENCES, DETENTION PONDS, HARD SURFACE
PATHS, FILL, DRIVEWAYS, PARKING AREAS, VEGETATION, ETC.) IS ALLOWED WITHIN
THE 100-YEAR FLOODWAY AS LONG AS IT CAN BE PROVEN THAT THE DEVELOPMENT
WILL NOT CAUSE A RISE IN THE BASE FLOOD ELEVATION (BFE) OR A CHANGE TO THE
FLOODWAY OR FLOOD FRINGE BOUNDARIES. NONSTRUCTURAL DEVELOPMENT IS
NOT RESTRICTED WITHIN THE FLOOD FRINGE.
10. ANY AND ALL CONSTRUCTION ACTIVITIES IN THE FLOODWAY OR FLOOD FRINGE
MUST BE PRECEDED BY AN APPROVED FLOODPLAIN USE PERMIT. IF THE
CONSTRUCTION IS IN THE FLOODWAY A NO-RISE CERTIFICATION MUST BE
APPROVED PRIOR TO CONSTRUCTION.
11. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD88.
SEE COVER SHEET FOR BENCHMARK REFERENCES.