Loading...
HomeMy WebLinkAboutBUCKING HORSE FILING FOUR, MIXED-RESIDENTIAL - FDP - FDP160023 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSPROSPECT RD. TIMBERLINE ROAD BLACKBIRD DRIVE BEAR MOUNTAIN DRIVE NANCY GRAY AVE. KATAHDIN DR. PROSPECT RD. TIMBERLINE ROAD DRAKE ROAD SCARECROW RD KATAHDIN DR. GREAT WESTERN RAILROAD BUCKING HORSE - FILING ONE BUCKING HORSE - FILING TWO BUCKING HORSE - FILING THREE CS1 COVER SHEET A. Reese L. Seeber N/A MAY 2016 I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: VICINITY MAP NORTH 1"=1500' Northern Engineering Services, Inc. Project No. 687-004 Date: October 2015 ORIGINAL FIELD SURVEY BY: PROJECT BENCHMARKS: CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CS2 CONSTRUCTION NOTES GENERAL NOTES & A. Reese L.Seeber N.A. A. GENERAL NOTES 1. All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the Final Drainage Report For Bucking Horse Apartments, dated May 11, 2016 by Northern Engineering shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. W W W W W W W W W W W W W W W W W W W W W W W W W W W W W S W S S S S S S S S S W W W W W W W W UD UD WWWW W WWWW W W W W W W W W W W W S S W W W W W W W \A1;38.6' X X X X X X X X X X X X X X X X X X X E E X X MILES HOUSE AVENUE GOOSEBERRY LANE YEARLING ROAD VAN X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X VAN TF TF TF TF TF TF TF TF TF TF TF TF TF TF TF TF TF EM EM EM EM GM EM GM GM GM GM GM EM GM GM GM GM TF GM GM GM GM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM GM GM GM GM GM EM GM W W W W S W S S S S W W W W W W W W W W W W W W W W W W W X X X X X X X X X X X X X X X X X X X X X X C O CO CO CO CO S S TF TF TF TF TF TF EM GM GM GM GM EM GM GM GM EM EM EM EM EM EM EM EM EM GM EM GM EM W W W W W W W W W W W W W W W W W W W W W SS SS X X X X X X X X X X X X X X X X X X X X X CO CO CO CO CO W W W S TF TF TF TF TF EM EM EM GM GM GM GM GM EM EM EM EM EM EM EM GM GM GM GM W W W W W W W W W W W W W W W W W W W W W S W S S S S S S S S S W W W W W W W W S S W W W W S W S W W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W CO CO CO CO CO SS SS SS W W W W W W W W W W W W W W W W W W W W W W W W W UD UD UD UD WWWW W WWWW W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS CO CO CO CO VAN TF TF TF TF TF TF TF TF TF TF TF EM EM EM EM GM GM GM EM GM GM GM TF EM EM EM EM EM EM EM EM EM GM GM GM EM GM GM GM EM GM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM X X X X X X X X X X TF TF TF TF EM GM GM GM GM GM EM EM EM EM EM EM EM EM EM GM GM GM GM X X X X X X X X X X S S S S W FDC FDC FDC FDC FDC S W F F F F F W W W CO CO S SS SS SS SS SS SS SS SS SS SS SS S S SSMH B3 STA 14+67.06 N: 17467.55 E: 12056.29 SSMH B2 STA 13+53.60 N: 17394.07 W W W W W W W W W W W W W W W W W W X X X CO CO CO CO SS SS S EM GM GM EM GM EM EM GM EM GM FO VAULT F.O. WV H Y D WV WV WV WV WV WV WV GAS h2o GAS WV H Y D h2o GAS WV WV S C T SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS S X X CO S GM EM S IR LUSITANO LANE (PRIVATE DRIVE) INLET B1 STA 10+70.47 N: 17671.70 E: 12156.49 INLET B2 STA 11+77.79 N: 17589.92 E: 12086.98 FES B STA 10+00.00 N: 17725.39 E: 12202.13 70.47 LF 24" RCP 107.33 LF 24" RCP @ 0.50% @ 0.50% BLDG 1 EXISTING 2' CONCRETE PAN INSTALL 2' CONCRETE PAN LID VAULT H Y D SS SS SS SS SS SS SS S W W W W CO TF EM GM EM GM EM GM S W F LUSITANO LANE (PRIVATE DRIVE) BLDG 5 BLDG 4 INLET D2 STA 12+75.41 N: 16993.91 E: 12634.82 STMH D1 STA 10+68.76 N: 17151.82 E: 12768.09 FO C T CO CO \A1;38.6' W W X X X X X X X X X X X X X X X X X X X E E X X VAN TF TF TF TF TF TF TF TF TF TF TF TF TF TF TF TF TF TF TF X X X X X X X X X X X X X X X X X X X X X X X X X 92.30 TF TF TF TF TF TF EM GM GM GM GM EM GM GM GM EM EM EM EM EM EM EM EM EM GM EM GM EM GM GM GM GM X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 92.46 92.30 TF TF TF TF TF EM EM EM GM GM GM GM GM EM EM EM EM EM EM EM GM GM GM GM GM TF EM GM EM GM EM GM X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X VAN TF TF TF TF TF TF EM EM GM GM EM GM GM TF EM EM EM EM EM GM GM GM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM X X X X X X X X X X X X X X X X X X X X X X X X X TF TF TF EM GM GM GM EM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X FO VAULT F.O. GAS GAS GAS C T GAS CO CO UD UD UD UD UD UD \A1;38.6' X X X X X X X X X X X X X X X X X X X X X X W WV V E E X D ST ST ST ST ST WV W W D D D D D WV T T T T VAN TF TF TF TF \A1;38.6' FO VAULT F.O. C T VAN EM EM EM EM GM EM GM GM GM GM GM EM GM GM GM GM GM GM GM GM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM GM GM GM GM GM EM GM GM GM EM EM GM GM GM GM CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Drng\687-004_EROS.dwg LAYOUT NAME: EC2 DATE: May 10, 2016 - 3:29pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xUTIL] [687-004_xADJ] [687-004_xEXST] [687-004_xGRAD] [687-004_xSITE] [687-004_xTOPO] [NES-xborder] [687-004_3D_Proposed] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Details\687-004_DETL UTIL.dwg LAYOUT NAME: D1 DATE: May 10, 2016 - 3:29pm CAD OPERATOR: luke LIST OF XREFS: [NES-xborder] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four D1 SEWER DETAILS A. Reese L. Seeber NTS Date Date Date Date Date Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: City Engineer Water & Wastewater Utility Stormwater Utility Parks & Recreation Traffic Engineer Environmental Planner City of Fort Collins, Colorado UTILITY PLAN APPROVAL No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Details\687-004_DETL UTIL.dwg LAYOUT NAME: D2 DATE: May 10, 2016 - 3:36pm CAD OPERATOR: luke LIST OF XREFS: [NES-xborder] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four D2 WATER DETAILS A. Reese L. Seeber NTS Date Date Date Date Date Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: City Engineer Water & Wastewater Utility Stormwater Utility Parks & Recreation Traffic Engineer Environmental Planner City of Fort Collins, Colorado UTILITY PLAN APPROVAL No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Details\687-004_DETL UTIL.dwg LAYOUT NAME: D3 DATE: May 10, 2016 - 3:29pm CAD OPERATOR: luke LIST OF XREFS: [NES-xborder] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four D3 WATER DETAILS A. Reese L. Seeber NTS Date Date Date Date Date Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: City Engineer Water & Wastewater Utility Stormwater Utility Parks & Recreation Traffic Engineer Environmental Planner City of Fort Collins, Colorado UTILITY PLAN APPROVAL No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Details\687-004_DETL DRAINAGE.dwg LAYOUT NAME: D4 DATE: May 10, 2016 - 3:30pm CAD OPERATOR: luke LIST OF XREFS: [NES-xborder] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four D4 DRAINAGE DETAILS A. Reese L. Seeber NTS Date Date Date Date Date Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: City Engineer Water & Wastewater Utility Stormwater Utility Parks & Recreation Traffic Engineer Environmental Planner City of Fort Collins, Colorado UTILITY PLAN APPROVAL No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Details\687-004_DETL DRAINAGE.dwg LAYOUT NAME: D5 DATE: May 10, 2016 - 3:30pm CAD OPERATOR: luke LIST OF XREFS: [NES-xborder] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four D5 DRAINAGE DETAILS A. Reese L. Seeber NTS Date Date Date Date Date Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: City Engineer Water & Wastewater Utility Stormwater Utility Parks & Recreation Traffic Engineer Environmental Planner City of Fort Collins, Colorado UTILITY PLAN APPROVAL No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Details\687-004_DETL-SITE.dwg LAYOUT NAME: D6 DATE: May 10, 2016 - 3:30pm CAD OPERATOR: luke LIST OF XREFS: [NES-xborder] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four D6 SITE DETAILS A. Reese L. Seeber N/A CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R 1' RAD. (TYP.) WALK LANDSCAPED PLAN ISOMETRIC PLAN ISOMETRIC VARIES LANDSCAPED AREA (SEE PLAN) LANDSCAPED AREA VARIES (SEE PLAN) MAX. 12:1 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Details\687-004_DETL-SITE.dwg LAYOUT NAME: D7 DATE: May 10, 2016 - 3:30pm CAD OPERATOR: luke LIST OF XREFS: [NES-xborder] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four D7 SITE DETAILS A. Reese L. Seeber N/A NOT TO SCALE 410 D7 SIGN POST Max. Sign Panel 1. Attach the sign panels tightly to the post and use oversized washers to keep the sign from breaking loose from the post when hit by a vehicle. 2. Sign panels should be mounted a minimum of 7 feet above the pavement or ground. Cross section of post 3" - 6" ABOVE GRADE 2 1/4" Anchor 3. Signs larger than 36 inches in length or width require wind bracing and special post design. NOTES: 4. Anchor Stub and post are square steel tube (perforated). Anchor/Stub Post Size CRITERIA FOR SINGLE POST 36" x 36" 2.25" x 2.25" x 3'-0" 2" x 2" x 12'-0" 5. All "No Parking" signs shall be installed at 45° from Flow Line. * * 2" x 2" x 10' OR 12' 12 GAUGE TELESPAR POST (22F12A31) 7'-0" MIN. CLEARANCE 2' - 3' FROM F Street Curb REVISION NO: 1 DATE: 04/01/07 STREET STANDARDS CONSTRUCTION DRAWINGS SIGN POST URBAN AREA LARIMER COUNTY DRAWING 1401 See Figure 16-1 SW SAMPLE AVE 2400 R1-1 "STOP" SIGN 30" HIGH DENSITY/DIAMOND GRADE. SIGN MOUNTED TO POST WITH 1 EACH DRIVE RIVET WITH NYLON WASHER AGAINST SIGN FACE (ON TOP OF THE SIGN). THE BOTTOM OF THE SIGN SHALL BE MOUNTED WITH 1 EACH 5/16"x2-1/2" HEW BOLT WITH METAL AND FROM NYLON WASHERS (NYLON WASHER AGAINST SIGN FACE) AND SECURED WITH 1 EACH 5/16" HEX NUT ON THE BACK SIDE OF POST. L 2-1/4" x 2-1/4" x 3' ANCHOR/STUB 2 EACH 8" BLADES MOUNTED TO POST WITH 4 EACH DRIVE RIVETS WITH NYLON WASHERS * 12 Gauge 30" 8" 8" NOT TO SCALE TRENCH DETAIL 12" (Water & Sewer) If this section is less than 4' of existing asphalt/concrete, it must be removed and replaced. Edge of Pavement or Lip of Existing Gutter Compacted Lifts of Suitable Materials Pavement Thickness Varies Varies 1" (min.) (See Note 9 below for Storm.) 4" (min.) 6" (max.) Trench Width Varies 2' (min.) Bedding Material Undisturbed Soil Utility Conduit New Asphalt/Concrete Clean Road Base Existing Road Base 6" Full Depth Asphalt or X/Y Composite Section NOTES: 1. All trenches shall be backfilled in accordance with the above detail unless otherwise specified by the Local Entity Engineer. 2. Prior to placement of asphalt/concrete, pavement edge shall be saw cut to a clean, vertical, and straight edge. 3. Where the surrounding soils are non-expansive, a sand/cement slurry (1 sack mix) may be substituted for backfill material. 4. Trench width shall not be more than 16" nor less than 12" wider than the outside diameter of the pipe. 5. Use a #4 rebar at centers along the perimeter of concrete replacement sections. 6. Refer to Chapter 22, Materials & Construction Specifications for compaction and testing requirements. 7. In unimproved areas, all disturbed areas shall be regraded, seeded & mulched. 8. In concrete roadways, a minimum of one entire concrete panel must be replaced. 9. Bedding material depth when installing storm sewer shall be up to spring line, except in areas of unsuitable backfill; then, bedding material shall be placed to a level 12" above pipe. LARIMER COUNTY URBAN AREA STREET STANDARDS CONSTRUCTION DRAWINGS REVISION NO: 1 DRAWING 2201 DATE: 08/07/00 TRENCH DETAIL NOT TO SCALE SIDEWALK DETAIL ATTACHED SIDEWALK DETAIL Slope sidewalk to curb 1/4" per foot. NOTE: Construct sidewalk with joints at 10' intervals R 1/8" WEAKENED PLANE JOINT EXPANSION JOINT R1/4" and aligned with scoring on curb. INSTALL IN LOCATIONS SPECIFIED IN CHAPTER 22 1/2" 1/4" 1/4 SLAB THICKNESS 1/4" 1/2" Expansion Joint material DETACHED SIDEWALK DETAIL Variable Landscaping Slope sidewalk to curb 1/4" per foot. 2' min. Slope: Minumum 1 4"/ft Maximum 3"/ft CONSTRUCTION SIDEWALK DETAIL LARIMER COUNTY STREET URBAN STANDARDS AREA DRAWINGS 1602 DRAWING REVISION DATE: 04/NO: 01/07 2 NOT TO SCALE STANDARD SIDEWALK Sidewalk Driveway LIP F.L. T.C. DRIVEWAY SIDEWALK SECTION A-A NOTE: 1. Sidewalk grade shall remain consistent across driveway 3. This detail applies to Residential & Commercial driveways. 6" 6" Residential Detached Sidewalk Attached Sidewalk 1/2" Expansion Joint Material 1/2" Expansion Joint Material A A 2. For driveway design requirements, see CONST. DWG. 706 & 707. DETACHED ATTACHED 3'-0" 6'-0" All Sidewalk Thickness Shall Be 6" minimum. Min. STANDARD SIDEWALK STREET STANDARDS LARIMER URBAN COUNTY AREA REVISION NO: 1 CONSTRUCTION DRAWINGS DATE: 04/01/07 1601 DRAWING SIDEWALK 8" Commercial CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NOT TO SCALE BICYCLE RACK FOUNDATION DETAIL City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner VAN- ACCESSIBLE PARKING MIN. MIN. CAR ACCESSIBLE VAN ACCESSIBLE OR 8' 5' 8' 8' 8' 8' 11' 5' 11' 11' 5' RESERVED RESERVED PARKING RESERVED PARKING NOT TO SCALE HANDICAP PARKING REQUIRMENTS PLAN-CONCRETE PAD 4" Concrete Pad ELEVATION Existing Ground 4" Concrete Pad 6'-6" 13'-0" by field Engineer or as directed 2'-0" CL CL Inverted "U" Inverted "U" 1'-6" ONE IN EVERY EIGHT ACCESSIBLE SPACES, BUT NOT LESS THAN ONE, SHALL BE VAN ACCESSIBLE. ONE SIGN PER SPACE REQUIRED R7-8 ONE SIGN PER SPACE REQUIRED R7-8 A "UNIVERSAL" PARKING SPACE DESIGN MAY BE USED. THIS DESIGN IS USED TO ACCOMMODATE CAR & VAN ACCESSIBLE PARKING SPACES, WHICH ELIMINATES THE NEED FOR TWO SIGN TYPES. "UNIVERSAL DESIGN" CAR & VAN ACCESSIBLE ONE SIGN PER SPACE REQUIRED R7-8 NO PARKING TYPICAL PAVEMENT MARKINGS NOT TO SCALE 417 C507 PRIVATE CONCRETE CROSSPAN \A1;48" \A1;1"\A1;6" {NOTES: }1.PROVIDE CONTROL JOINTS AT 10' INTERVALS. 2.OPTION TO PROVIDE 4" THICK PAN W/ 6" X 6" - W14 X W14 WELDED WIRE REINFORCEMENT. ROUND STRAIGHT POLE (RE: ELEC) HAND HOLE AND COVER BOND GROUND WIRE TO METAL REBAR ANCHOR BOLTS (RE: ELEC) BASE COVER (RE: ELEC) GROUT AFTER LEVELING POLE 24" DIAMETER CONCRETE POLE BASE BY G.C. WITH 1" RADIUS, (4) #4 w/ #4 REBAR TIES AT 12" O.C. FINISHED GRADE 6'-0" VARIES 6" 24" MINIMUM 3 4" CONDUIT IN AND OUT 2' MIN. BELOW GRADE NOTE: CONTRACTOR SHALL COORDINATE AND CONFIRM ALL SITE LIGHTING WITH ELECTRICAL ENGINEER AND ARCHITECT. NOT TO SCALE LIGHT POLE BASE 411 D7 412 D7 413 D7 414 D7 415 D7 416 D7 BUILDING 12:MAX. 1 1.RAMP DETAILS ARE PROVIDED TO ILLUSTRATE CONCEPTS ONLY. 2.SEE SHEETS G1-G4 FOR SITE-SPECIFIC SLOPES AND RAMP ELEVATIONS. 3.CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT EACH RAMP COMPLIES WITH SECTION 4.7 OF 'ADA STANDARDS FOR ACCESSIBLE DESGIN' (28 CFR PART 36, APPENDIX A) PRIOR TO POURING CONCRETE. RAMP NOTES: {NOTES: }1.ALL SITE GRADING, SUBGRADE PREPARATION AND PAVING SHALL FOLLOW THE GEOTECHNICAL RECOMMENDATIONS CONTAINED IN THE {GEOTECHNICAL INVESTIGATION - "TERRA VIDA II APARTMENTS"} BY CTL THOMPSON, INC. DATED SEPTEMBER 19, 2013 (PROJ. NO. FC06257-120), AND ANY SUBSEQUENT ADDENDA. 2.NOTE THAT THESE PAVING SECTIONS ARE TO BE USED ONLY FOR AREAS OUTSIDE OF PUBLIC RIGHT-OF-WAY. PAVING SECTIONS WITHIN PUBLIC RIGHT-OF-WAY WILL BE REQUIRED BY THE CITY OF FORT COLLINS TO BE PER AN APPROVED PAVEMENT DESIGN REPORT. 3.SEE CDOT STANDARD M-412-1 FOR TYPICAL CONCRETE PAVING JOINT LAYOUT. 4.CONCRETE PARKING LOT SHALL BE CONSTRUCTED IN ACCORDANCE WITH ACI 330R-08. LIGHT DUTY PAVING HEAVY DUTY PAVING NOT TO SCALE PAVING SECTIONS (PRIVATE AREAS OUTSIDE ROW) CONCRETE {PAVEMENT SECTION } 6" CONCRETE CONCRETE { PAVEMENT SECTION } 5" CONCRETE NOT TO SCALE PRIVATE OUTFALL VERTICAL CURB & GUTTER 1" 6" 4 1/6" 2" 1 1/2" 1'-6" 6" 12" 1'-6" 1 1/2" 6" 1" 6" 6" 4 1/2" 12" NOT TO SCALE PRIVATE INFLOW VERTICAL CURB & GUTTER NOT TO SCALE RAMP DETAIL NOT TO SCALE RAMP DETAIL NOT TO SCALE 400 D6 PEDESTRIAN RAMP DETAIL 1. NO JOINTS ARE ALLOWED IN THE FLOWLINE. SIX INCH WIDE CURB OR "DUMMY JOINT" MAY BE TOOLED NO CLOSER THAN 6 INCHES FROM FLOW LINE AS SHOWN. 2. MINIMUM CONCRETE THICKNESS IS 6 INCHES. 3. JOINT PATTERN TO BE ACCORDING TO 'INTERSECTION GUTTER DETAIL' OR AS DETERMINED BY THE LOCAL ENTITY. 4. WOOD FLOAT FINISH IS REQUIRED OVER THE SLOPED SURFACE OF RAMP AND FLARES. 5. A 6 INCH WIDE CURB MAY BE POURED AT THE BACK OF THE RAMP AS SHOWN IF REQUIRED. IF CURB IS USED IT SHALL MATCH THE CURB AND GUTTER STYLE OF ADJACENT CURB AND GUTTER. 6. MINIMUM RAMP WIDTH SHALL BE FOUR FEET, OR THE SAME AS THE WIDEST ADJACENT SIDEWALK, WHICHEVER IS GREATER, UP TO A MAXIMUM WIDTH OF 8 FEET. 7. THE RAMP LANDING MAY BE POURED MONOLITHIC WITH THE ADJACENT TRANSITIONS PROVIDED THAT AN APPROVED "SHAKE-ON" PIGMENT BE USED TO COLOR THE LANDING AREA. 8. T= THICKNESS (AS SPECIFIED ON PLANS OR LOCAL ENTITY ENGINEER). STANDARD GRAY CONCRETE RAMP WITH PARTIALLY COLORED CONCRETE SECTION A-A LIP OF GUTTER PLAN VIEW FLOWLINE CURB A A 0.5' TYP. N.T.S. 6" 1:12 SLOPE MAX. CURB 0.5' 4' MIN. N.T.S. FLARE OPTION CURB OPTION 6" CURB 0" CURB 1' R 2' NOTES: t=6" or as specified 1"/ft. Max 1"/ft. Max 1.5' TRANSITION 1.5' TRANSITION Flared Option 2' FL REVISION NO: 1 DATE: 04/01/07 DRAWING STREET STANDARDS DRAWINGS 1606 URBAN AREA LARIMER COUNTY PEDESTRIAN RAMP DETAIL (For New Const. & Alterations) CONSTRUCTION 1:25 slope (max.) Truncated Dome Warning Detection Truncated Dome Warning Detection NOT TO SCALE TRUNCATED DOME WARNING FOR ACCESS RAMPS F Curb Flare Varies Curb 2'-0" Flare Ramp concrete ramps Panels embedded in the Apron Gutter or Curb and Gutter Flow line 1:20 Slope 1:12 MAX Slope Section A-A NTS Varies Varies Curb Curb Flare Ramp 2'-0" Varies Panels Panels 6" A A CL Pedestrian flow Aligned with Ramp Width: 4.5' 5.0' 6.0' 7.0' 8.0' Note: Truncated dome panels are available in 2'x2' squares and 2'x2.5' rectangles. Combine the widths to fit the ramp. Panels may be cut to no less than a 2'x1.5' size. Panel Width Combinations: 2'+2.5' 2.5'+2.5' 2'+2'+2' 2.5'+2'+2.5' 2'+2'+2'+2' Note: 1. Truncated dome warning panel: Install panels along with the concrete pour for the ramp. The panel material shall be "Cast In Tact Warning Panels" or an equivalent material that must be first approved by the City Engineer prior to installation. The panel color shall be red, no other color is approved. Specifications for the panel and installation instructions will be provided upon request. 2. This drawing shows vertical curb. For Drive Over Curb the warning detection location shall be placed in the same position 6" back from the Face of Curb or . Case 1-Directional Ramps Case 2-Non-Directional Ramps Varies Panels Ramp Panels Flare 2'-0" Curb Case 3-Mid-Block Ramps 6" Panels Panels Apron Gutter or Flare 6" Flare (Center line of ramp) CL -Center line of ramp BOC BOC BOC FOC L or FL FOC BOC FL -Back of Curb -Face of Curb -Flow line 2' REVISION NO: DATE: 04/01/07 DRAWING STREET STANDARDS DRAWINGS 1607 URBAN AREA LARIMER COUNTY TRUNCATED DOME WARNING FOR ACCESS RAMPS CONSTRUCTION FORT COLLINS ONLY City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner R1 1/2" R2" R2" TRANSITION CURB TO 0" 6" CURB AREA TRANSITION CURB TO 0" 6" CURB WALK PLAN ISOMETRIC SEE PLAN BUILDING MAX. 12:1 NOT TO SCALE RAMP DETAIL CURB TRANSITION TO 0" CURB 6" NOT TO SCALE RAMP DETAIL RAMP TO BE FLUSH WITH PAVEMENT 12:1 MAX. 8' MIN WALK 10' MIN TRANSITION 6" CURB TO 0" CURB TRANSITION 6" CURB TO 0" CURB 12:1 MAX. 8' MIN RAMP TO BE FLUSH WITH PAVEMENT R1 1/2" 401 D6 402 D6 403 D6 404 D6 405 D6 406 D6 407 D6 408 D6 NOT TO SCALE 409 CONCRETE SIDEWALK CULVERT D6 GENERAL NOTES: 1. SIDEWALK SHALL BE 6 IN. THICK. 2. TOP SLAB OF CULVERT SHALL BE SLOPE TO MATCH SIDEWALK. SEE D-6. 3. EXPOSED STEEL SHALL BE GALVANIZED IN ACCORDANCE WITH AASHTO M-111. 4. KEY JOINTS WHERE WALLS CONNECT TO TOP SLAB AND BASE. 5. REINFORCEMENT IN WALLS AND BASE SHALL BE 3 IN. FROM THE SIDE EXPOSED TO EARTH. REINFORCEMENT IN TOP SLAB SHALL BE 1 1/2 IN. CLEAR. SECTION C-C #4@11" #5@18" #4@12" 11'-0" 1'-2 1/2" 12" 6" 4'-0" SECTION B-B DEPRESSED GUTTER SECTION A-A 2" 1 1/2" PIPE SPACER AND 4" 1" R 3"x3"x3/8" 1 1/4" DIA. x 14" GALV. STEEL ROD - THREADED 3 1/2" PLATE DETAIL 1 BACK OF #5@9" O.C. EXTEND WALK 6" ON BOTH SIDES OF WALK #4@11" O.C. SIDEWALK (TYP.) 3'-0" 6" VARIES VARIES 3'-6" 11'-0"' 4'-0" OPENING 12"' (TYP.) PLAN 3'-6" 6" A A B C C B #4@12" O.C. #5@9" #4@11" 0.5% SLOPE (MIN.) SEE DETAIL 1 VARIES VARIES 6" \A1;6" 8 1/2" (TYP.) (TYP.) (TYP.) #5@18" O.C. \A1;VARIES BACK OF #4@12" O.C. 2" 1 1/4"LOCK NUT EDGE OF STREET EDGE OF STREET #4@12" O.C. 1 1/4" DIA. ROD (SEE DETAIL 1) 12" R 12" R SLOPE #4@12" #4@12" #4@12" CURB AT TOP CURB EXPANSION MATERIAL EXPANSION MATERIAL APPROVED: DATE: DETAIL DRAWN BY: FORT COLLINS CONSTRUCTION STORMWATER DETAILS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 TDC 1-20-09 D-12B CONCRETE SIDEWALK CULVERT FOR DETACHED SIDEWALK FOR DETACHED WALK CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R DETAIL FORT COLLINS CONSTRUCTION STORMWATER DETAILS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 APPROVED: DATE: DRAWN BY: CONCRETE END SECTIONS 01/31/01 D-15 NBJ E C B E E E E F F PLAN C B D A RISE SPAN END VIEW PLAN E F M 206 SEE FOR FIGURE ACTUAL 1 OF AASHTO SIZES SECTION D F-FA RISSEPAN END VIEW F 3 IN. 5 IN. 5 IN. 3 IN. F 2 FT. 5 IN. 3/4 IN. GALVANIZED ANCHOR BOLTS, NUTS AND WASHERS, MILD STEEL, ASTM A 307. ROD LUG SHALL BE COATED WITH COAL-TAR EPOXY PAINT OR APPROVED EQUAL. 3/4 IN. "CANOPY" APPROVED, TYPE ROD EQUAL LUG, OR 2 FT. 7 IN. PIPE DIAMETER F 18 IN. - 30 IN. 36 IN. - 42 IN. 48 IN. - 60 IN. 72 IN. - 84 IN. 5 IN. 6 IN. 9 IN. CONCRETE JOINT FASTENER. LOCATION OF 1 IN. DIA. HOLES END SECTION FOR REINFORCED CONCRETE CIRCULAR PIPE END SECTION FOR REINFORCED CONCRETE ELLIPTICAL PIPE END SECTION FOR REINFORCED CONCRETE ARCH PIPE DIMENSIONS A B C D E PIPE I.D. IN. 12 15 18 24 30 36 42 48 54 60 72 5 1/2 11 1/2 12 17 18 24 28 27 36 34 1/2 23 26 26 43 53 60 61 70 65 58 75 49 47 48 54 43 37 36 28 35 40 21 72 73 74 97 96 97 97 98 100 98 96 24 29 36 48 60 71 78 84 90 96 108 IN. IN. IN. IN. IN. SECTION F-F 24 30 36 42 48 54 60 30 38 45 53 60 68 76 19 24 29 34 38 43 48 8 1/2 9 1/2 11 1/8 15 3/4 21 25 1/2 30 39 54 60 60 60 60 60 33 18 24 36 36 36 36 72 72 84 96 96 96 96 48 60 72 78 84 90 96 EQUIVALENT (INCHES) CIRCULAR DIAM. (IN.) NOMINAL (IN.) DIMENSIONS SPAN RISE A B C D E 24 30 36 48 54 DIAM. (IN.) CIRCULAR EQUIVALENT 42 60 72 96 96 96 96 96 (INCHES) 96 8 1/2 9 1/2 11 1/8 25 1/2 A DIMENSIONS 15 3/4 SPAN RISE 30 21 NOMINAL (IN.) B C 60 60 60 60 50 60 39 36 36 36 36 46 35 33 78 90 96 84 D 60 72 48 E 29 36 43 50 58 65 72 86 18 22 27 31 36 40 44 54 31 120 72 60 39 99 PLAN SECTION X-X GENERAL NOTES: 1. REVISED CDOH M-603-10 2. CONCRETE END SECTIONS ARE TO BE FURNISHED WITH TOUGE OR GROOVE AS REQUIRED. 3. INSIDE CONFIGURATION AND JOINT OF CONCRETE END SECTION AND PIPE SHALL MATCH. 4. CONCRETE PIPE JOINT FASTENERS, WHERE SHOWN ON PLANS, SHALL BE INSTALLED SO THAT A MINIMUM OF 15 LINEAR FEET OF THE OUTLET END OF THE ARE MECHANICALLY LOCKED TOGETHER. END SECTION LENGHTS, WHEN USED, WILL BE INCLUDED IN THE 15 L.F. REQUIRED. END VIEW + NOT TO SCALE STANDARD CONCRETE NOTES CONCRETE END SECTIONS STANDARD CONCRETE NOTES 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE LATEST VERSION OF ACI 318, ACI 304, AND ACI 315. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4,000 PSI AT 28 DAYS WITH 4%-6% ENTRAINED AIR AND TYPE II CEMENT UNLESS NOTED OTHERWISE. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, DEFORMED UNLESS NOTED OTHERWISE. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 WELDED STEEL WIRE FABRIC UNLESS NOTED OTHERWISE. SPLICES SHALL BE CLASS "B". ALL HOOKS SHALL BE STANDARD UNLESS NOTED OTHERWISE. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: CONCRETE CAST AGAINST EARTH = 3" CONCRETE EXPOSED TO EARTH OR WEATHER: #6 AND LARGER = 2" #5 AND SMALLER AND WWF = 1 1/2" CONCRETE NOT EXPOSED TO WEATHER NOR CAST AGAINST EARTH: SLAB AND WALL = 3/4" BEAMS AND COLUMNS = 1 1/2" A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE UNLESS NOTED OTHERWISE IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. HOLES TO RECEIVE EXPANSION/WEDGE ANCHORS SHALL BE 1/8" LARGER IN DIAMETER THAT THE ANCHOR BOLT, DOWEL OR ROD AND SHALL CONFORM TO MANUFACTURER'S RECOMMENDATION FOR EMBEDDMENT DEPTH OR AS SHOWN ON THE DRAWINGS. LOCATE AND AVOID CUTTING EXISTING REBAR WHEN DRILLING HOLES IN ELEVATED CONCRETE SLABS. USE AND INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHORS SHALL BE PER ICBO AND MANUFACTURER'S WRITTEN RECOMMENDED PROCEDURES. 2. 3. 5. 6. 7. 4. DETAIL FORT COLLINS CONSTRUCTION STORMWATER DETAILS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 APPROVED: DATE: DRAWN BY: STANDARD CONCRETE NOTES 2/22/05 D-41 TDC NOT TO SCALE 308 SINGLE COMBINATION INLET D5 NOT TO SCALE DOUBLE COMBINATION INLET 3" 5" 4-1/2" SUPPORT BEAM POCKET DETAIL AND ASTM C858-83. 2. DESIGNED ACCORDING TO ASTM C857-87 1. DESIGNED FOR AASHTO HS-20 LOADING. NOTES: IF RISER IS REQUIRED THE BASE IS POURED WITH A "SHIP-LAP" JOINT. 6'-1" 2'-0" GRATING (SEE DETAIL, THIS DRAWING) GRATING DETAIL 3. 2. WEIGHT: 1100 LBS 1. NOTES: ISOMETRIC VIEW PLAN VIEW N.T.S. \A1;7'-\1" A1;6" \A1;6" \A1;2' \A1;6" N.T.S. \A1;6" 5'-8" MAX 3'-0" MIN M.A. STEPS @12" O.C. 4 TON P52 SL ANCHORS (NUMBER REQ'D VARIES WITH HEIGHT) 5'-8" MAX 3'-0" MIN \A1;6" N.T.S. SECTION B-B \\A1;A1;6" 6'-1" POCKET FOR SUPPORT BEAM (SEE DETAIL, THIS DRAWING) 3) STEEL REINFORCEMENT: 4) CEMENT: ASTM C-150 SPECIFICATIONS 1) 4 TON P-52 SL ANCHORS (8 REQ'D) A. AASHTO HS-20-44, W/ IMPACT C. EQUIVALENT FLUID PRESSURE = 45 PCF D. 80 PSF LATERAL LIVE LOAD SURCHARGE B. SOIL WEIGHT = 120 PSF 2) CONCRETE 28 DAY COMPRESSIVE STRENGTH SHALL BE DESIGN NOTES: 4500 PSI (MIN.) 1) DESIGN LOADINGS: LIFTING NOTES: FRAME & GRATING NOT SHOWN 4 TON P-52 SL ANCHORS FOR SETTING A. REBAR, ASTM A-615 GRADE 60, MIN. OF 2" CLR. B. MESH, ASTM A-497 GRADE 80 DATE DRAWN: 3/3/05 D44.dwg DRAWN BY: T. COX CAD FILE NAME: N.T.S. N.T.S. N.T.S. 6'-8" 2'-7" 4" CURB ADJUSTS 6" 3 1/4" TO 9" DESIGNED ACCORDING TO ASTM C857-87 AND ASTM C858-83 DESIGNED FOR AASHTO HS-20 LOADING EAST JORDON IRON WORKS CURB INLET 7031 (OR EQUAL) TYPE M2 GRATE AND T1 BACK COMBINATION. \A1;3' GRATING (SEE DETAIL, THIS DRAWING) POCKET FOR SUPPORT BEAM (SEE DETAIL, THIS DRAWING) PIPE(S) SIZE, SHAPE AND LOCATION VARIES A A SECTION A-A B B A A DIRECTION SECTION IS VIEWED) SECTION LINE A-A (ARROWS POINT IN LEGEND PIPE(S) SIZE, SHAPE AND LOCATION VARIES 6" THICK CONCRETE WALL OPEN AREA: 520 SQ. IN. DETAIL DOUBLE CURB INLET D-44 STORMWATER CONSTRUCTION DETAILS (970) 221-6700 P.O. BOX 580, FORT COLLINS, CO. 80522 CITY OF FORT COLLINS UTILITIES FACE CURB 2'-0" TRANSITION BACK OF CURB LIP OF GUTTER/EDGE OF ASPHALT TO BE FLUSH WITH CAST IRON FRAME LIP OF GUTTER CURB TRANSITION AT INLET N.T.S. STAKING NOTES: 1) CONTRACTOR SHALL HAVE ALL FOUR (4) CORNERS OF INLET BOX STAKED IN FIELD BY A QUALIFIED SURVEYOR PRIOR TO SETTING BOX. 2) CONTRACTOR SHALL ALSO HAVE A MINIMUM OF 20-FEET OF INCOMING CURB AND GUTTER IN EACH DIRECTION STAKED WITH THE INLET BOX. RUN STRING IF NECESSARY TO ENSURE PROPER CURB TRANSITION CAN BE MADE, AND THAT NO CONFLICTS ARISE. IF RISER IS REQUIRED THE BASE IS POURED WITH A "SHIP-LAP" JOINT. 2'-0" 3'-0" GRATING (SEE DETAIL, THIS DRAWING) %%UGRATING DETAIL 3. 2. WEIGHT: 560 LBS 1. %%UNOTES:%%U %%uISOMETRIC VIEW N.T.S. \A1;\A1;4' 6" \A1;6" \A1;2' \A1;6" N.T.S. \A1;6" 5'-8" MAX 3'-0" MIN M.A. STEPS @12" O.C. 4 TON P52 SL (NUMBER REQ'D VARIES WITH HEIGHT) 5'-8" MAX 3'-0" MIN \A1;6" N.T.S. %%USECTION B-B \A1;\A1;6" 3' 3) STEEL REINFORCEMENT: 4) CEMENT: ASTM C-150 SPECIFICATIONS 1) 4 TON P-52 SL ANCHORS (8 REQ'D) A. AASHTO HS-20-44, W/ IMPACT C. EQUIVALENT FLUID PRESSURE = 45 PCF D. 80 PSF LATERAL LIVE LOAD SURCHARGE B. SOIL WEIGHT = 120 PSF 2) CONCRETE 28 DAY COMPRESSIVE STRENGTH SHALL BE %%UDESIGN NOTES: 4500 PSI (MIN.) 1) DESIGN LOADINGS: %%ULIFTING NOTES: FRAME & GRATING NOT SHOWN 4 TON P-52 SL ANCHORS FOR SETTING A. REBAR, ASTM A-615 GRADE 60, MIN. OF 2" CLR. N.T.S. B. MESH, ASTM A-497 GRADE 80 N.T.S. DESIGNED ACCORDING TO ASTM C857-87 AND ASTM C858-83 DESIGNED FOR AASHTO HS-20 LOADING EAST JORDON IRON WORKS CURB INLET 7030 (OR EQUAL) TYPE M2 GRATE AND T1 BACK COMBINATION. \A1;3' GRATING (SEE DETAIL, THIS DRAWING) PIPE(S) SIZE, SHAPE AND LOCATION VARIES A A %%USECTION A-A B B A A DIRECTION SECTION IS VIEWED) SECTION LINE A-A (ARROWS POINT IN LEGEND PIPE(S) SIZE, SHAPE AND LOCATION VARIES OPEN AREA: 260 SQ. IN. CURB ADJUSTS 4" 2'-7" 3'-7" 6" 3 1/4" TO 9" ANCHORS DATE DRAWN: 3/3/05 D43.dwg DRAWN BY: T. COX SINGLE CURB INLET CAD FILE NAME: DETAIL D-43 STORMWATER CONSTRUCTION DETAILS P.O. BOX 580, FORT COLLINS, CO. 80522 CITY OF FORT COLLINS UTILITIES STAKING NOTES: 1) CONTRACTOR SHALL HAVE ALL FOUR (4) CORNERS OF INLET BOX STAKED IN FIELD BY A QUALIFIED SURVEYOR PRIOR TO SETTING BOX. 2) CONTRACTOR SHALL ALSO HAVE A MINIMUM OF 20-FEET OF INCOMING CURB AND GUTTER IN EACH DIRECTION STAKED WITH THE INLET BOX. RUN STRING IF NECESSARY TO ENSURE PROPER CURB TRANSITION CAN BE MADE, AND THAT NO CONFLICTS ARISE. FACE CURB 2'-0" TRANSITION BACK OF CURB LIP OF GUTTER/EDGE OF ASPHALT TO BE FLUSH WITH CAST IRON FRAME LIP OF GUTTER CURB TRANSITION AT INLET N.T.S. 309 D5 311 D5 312 D5 3" 5" 4-1/2" %%USUPPORT BEAM POCKET DETAIL AND ASTM C858-83. 2. DESIGNED ACCORDING TO ASTM C857-87 1. DESIGNED FOR AASHTO HS-20 LOADING. NOTES: IF RISER IS REQUIRED THE BASE IS POURED WITH A "SHIP-LAP" JOINT. 9'-2" 2'-0" GRATING (SEE DETAIL, THIS DRAWING) %%UGRATING DETAIL 3. 2. WEIGHT: 1640 LBS 1. %%UNOTES:%%U %%uISOMETRIC VIEW N.T.S. \A1;122.000\0A1;6.0000 \A1;6.0000 \A1;24.0000 \A1;6.0000 N.T.S. \A1;6.0000 68.0000 MAX 3'-0" MIN M.A. STEPS @12" O.C. 4 TON P52 SL ANCHORS (NUMBER REQ'D VARIES WITH HEIGHT) 68.0000 MAX 3'-0" MIN \A1;6.0000 N.T.S. %%USECTION B-B \A1;6.\0000 A1;110.0000 POCKET FOR SUPPORT BEAM (SEE DETAIL, THIS DRAWING) 3) STEEL REINFORCEMENT: 4) CEMENT: ASTM C-150 SPECIFICATIONS 1) 4 TON P-52 SL ANCHORS (8 REQ'D) A. AASHTO HS-20-44, W/ IMPACT C. EQUIVALENT FLUID PRESSURE = 45 PCF D. 80 PSF LATERAL LIVE LOAD SURCHARGE B. SOIL WEIGHT = 120 PSF 2) CONCRETE 28 DAY COMPRESSIVE STRENGTH SHALL BE %%UDESIGN NOTES: 4500 PSI (MIN.) 1) DESIGN LOADINGS: %%ULIFTING NOTES: FRAME & GRATING NOT SHOWN 4 TON P-52 SL ANCHORS FOR SETTING A. REBAR, ASTM A-615 GRADE 60, MIN. OF 2" CLR. B. MESH, ASTM A-497 GRADE 80 I:\StmWtr\Criteria Manual\D45.dwg 4/7/11 DATE DRAWN: 3/3/05 D45.dwg DRAWN BY: T. COX TRIPLE CURB INLET CAD FILE NAME: N.T.S. N.T.S. N.T.S. 9'-9" CURB ADJUSTS 4" 2'-7" 3 1/4" TO 9" 6" DESIGNED ACCORDING TO ASTM C857-87 AND ASTM C858-83 DESIGNED FOR AASHTO HS-20 LOADING EAST JORDON IRON WORKS CURB INLET 7032 (OR EQUAL) TYPE M2 GRATE AND T1 BACK COMBINATION. \A1;36.0000 GRATING (SEE DETAIL, THIS DRAWING) POCKET FOR SUPPORT BEAM (SEE DETAIL, THIS DRAWING) PIPE(S) SIZE, SHAPE AND LOCATION VARIES A A %%USECTION A-A B B A A DIRECTION SECTION IS VIEWED) SECTION LINE A-A (ARROWS POINT IN LEGEND PIPE(S) SIZE, SHAPE AND LOCATION VARIES 6" THICK CONCRETE WALL OPEN AREA: 780 SQ. IN. DETAIL D-45 STORMWATER CONSTRUCTION DETAILS (970) 221-6700 P.O. BOX 580, FORT COLLINS, CO. 80522 CITY OF FORT COLLINS UTILITIES NOT TO SCALE 310 DOUBLE COMBINATION INLET D5 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NOT TO SCALE 300 D4 STORMWATER BEDDING REQUIREMENTS CLASS B BEDDING LOWER LIMIT OF UNIFORM GRADED CLASS A BEDDING LOWER LIMIT OF LOWER LIMIT OF MATERIAL TRENCH WIDTHS SHALL BE AS SPECIFIED ON PLANS. REFER TO THE STORM SRAINAGE CONSTRUCTION STANDARDS, SECTION 6, "BEDDING MATERIALS" FOR GRADATIONS. SUBDRAIN DETAIL TRENCH WIDTH AS SPECIFIED TRENCH WIDTH AS SPECIFIED ROCK EXCAVATION TRENCH WIDTH AS SPECIFIED GRANULAR MATERIAL UNSTABLE SUBGRADE TRENCH WIDTH AS SPECIFIED ROCK 1 1/2 IN. COMPACTED GRANULAR OR TRENCH WALL SLOPE COMPACTED MATERIAL GRANULAR %%UNOTES: 2. 1. 6 IN. MIN. 4 IN. MIN. \A1;1/8 PIPE O.D. OR 4 IN. MIN. SLOTTED PIPE PERFORATED OR GRAVEL FILTER BACKFILL COMPACTED DENSELY TRENCH WIDTH AS SPECIFIED CLASS C BEDDING TRENCH WIDTH AS SPECIFIED \A1;1/4 PIPE O.D. SLOPE MATERIAL COMPACTED TRENCH DENSELY WALL \A1;PIPE O.D. + 8 IN. \A1;1/4 PIPE O.D. MATERIAL COMPACTED DENSELY SLOPE TRENCH WALL MATERIAL \A1;PIPE O.D. OR 6 IN. MIN. \A1;1/8 PIPE O.D. 3000 CONCRETE P.S.I. TRENCH WALL LOWER LIMIT OF UNIFORMLY SELECTED GRADED SLOPE GRADED COMPACTED ROCK OR MATERIAL GRANULAR COMPACTED \A1;PIPE O.D. TRENCH WALL LOWER LIMIT OF SLOPE COMPACTED DENSELY FILTER 6 IN. MIN. \A1;PIPE O.D. \OR A1;4 1/IN. 8 PIPE MIN. O.D. \A1;PIPE O.D. BROKEN LARGE (IF CONCRETE, REQUIRED) STONES, ETC. MATERIAL LOWER LIMIT OF TRENCH WALL SLOPE DETAIL FORT COLLINS CONSTRUCTION STORMWATER DETAILS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 APPROVED: DATE: DRAWN BY: STORMWATER BEDDING REQUIREMENTS 1/12/00 D-1 SKC DETAIL FORT COLLINS CONSTRUCTION STORMWATER DETAILS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 APPROVED: DATE: DRAWN BY: STANDARD MANHOLE 11/7/00 D-3 NBJ MANHOLE SHALL BE AS FOLLOWS: NOTE: MINIMUM INSIDE DIAMETER OF 27 IN. TO 42 IN. (INCL.) 24 IN. OR LESS VARIABLE ALTERNATE BASE 8 IN. MIN. 6 IN. 1 SLOPE IN./FT. RECAST MANHOLE BASE OVER 42 IN. PIPE SIZE 2 IN. MIN. POURED INVERT 8 IN. MIN. 1 FT. 1 IN./FT. SLOPE 2 IN. 18 IN. MAX 48 IN. MAX. DEPTH 30 IN. MIN. DEPTH 5 FT. MIN. DEPTH RUNGS 12" O.C. MANHOLE 8 IN. SEE NOTE 24 IN. 24 IN. RING AND COVER - 400 LB. OR APPROVED EQUAL DENVER HEAVY BY MACLEAR FINISHED GRADE 16 IN. MAX 28 IN. MAX 48 IN. 72 DIAMETER 60 IN. IN. MIN. MANHOLE POURED CONCRETE INSIDE AND OUT GROUT BASE TO CONE BASE MANHOLE SECTIONS ASTM C-478 INSIDE AND OUT GROUT SHIPLAP JOINT ECCENTRIC CONE ASTM C-478 GROUTED INSIDE AND OUT ADJUSTMENT SHIM BRICK &/OR CONCRETE STANDARD MANHOLE SHALLOW MANHOLE WITH FLAT TOP CHANNELING DETAILS FOR MANHOLES AREA INLET 301 D4 302 D4 303 D4 304 D4 GENERAL NOTES: 1. AREA INLETS MAY BE USED FOR DRAINAGEWAY OTHER THAN STREETS. (EXAMPLE, PARKING LOTS, MEDIANDS, SUMP BASINS) NO. 12 GRATE AND FRAME BY MaCLEAR OR APPROVED EQUAL. PLAN VIEW A A B B 35 3/4 IN. 6 IN. 23 3/4 IN. 3 IN. CIR. O.F. 2 IN. CIR L.F. #4 @ 12 IN. CTRS. (TYP.) #4 @ 12 IN. CTRS. F #4 BAR CONCRETE PIPE O.D. 3 IN. CIR. CONCRETE PIPE I.D. D SECTION A-A SECTION B-B 12 IN. LAP DRAINAGE SLOPE FOR INLET AND FLOW LINE OF CONDUIT PIPE AROUND #4 12 IN. MIN. INLET GRATES CTRS. (TYP.) #4 @ 12 IN. 2 IN. CIR L.F. 3 IN. CIR. O.F. 28 1/4 IN. 6 IN. 16 1/4 IN. H AND FLOOR 6 IN. TYPICAL WALLS 12 IN. SPACING STEP MAX. DETAIL FORT COLLINS CONSTRUCTION STORMWATER DETAILS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 APPROVED: DATE: DRAWN BY: NBJ 12/8/00 D-9A AREA INLET BEND WITH CURVED DEFLECTOR STRAIGHT DEFLECTOR BEND WITH INLINE UPSTREAM MAIN & 90 LATERAL WITH DEFLECTOR WITH DEFLECTOR DIRECTLY OPPOSED LATERAL (HEAD LOSSES ARE STILL EXCESSIVE WITH THIS METHOD, BUT ARE SIGNIFICANTLY MORE THAN WHEN NO DEFLECTOR EXISTS) DETAIL FORT COLLINS CONSTRUCTION STORMWATER DETAILS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 APPROVED: DATE: DRAWN BY: NJB 11/9/00 D-5 CHANNELING DETAILS FOR MANHOLES o DETAIL FORT COLLINS CONSTRUCTION STORMWATER DETAILS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 APPROVED: DATE: DRAWN BY: SHALLOW MANHOLE WITH FLAT TOP 11/8/00 D-4 NBJ PIPE SIZE MIN. MANHOLE DIAMETER 24 IN. OR LESS 27 IN. TO 42 IN. (INCL.) OVER 42 IN. 72 IN. 60 IN. 48 IN. NOTE: MINIMUM INSIDE DIAMETER OF MANHOLE SHALL BE AS FOLLOWS: ALTERNATE BASE POURED INVERT RECAST MANHOLE BASE 8 IN. MIN. 6 IN. 2 IN. MIN. SLOPE 1 IN./FT. BRICK &/OR CONCRETE ADJUSTMENT SHIM GROUTED INSIDE AND OUT FLAT SLAB TOP SECTION IN LIEU OF CONICAL TOP ASTM C-478 MANHOLE SECTIONS GROUT BASE TO CONE INSIDE AND OUT POURED CONCRETE BASE SEE NOTE MANHOLE RUNGS 12 IN. O.C. FINISHED GRADE 24 IN. RING AND COVER - 400 LB. DENVER HEAVY BY MACLEAR OR APPROVED EQUAL 8 IN. 1 FT. 5 FT. MAX. 16 IN. MAX SLOPE 1 IN./FT. 18 IN. MAX 2 IN. 8 IN. MIN. 28 IN. MAX ASTM C-478 AS NEEDED NOT TO SCALE DOUBLE AREA INLET (TYPE 13) 6" 6" 8" 6" 6" D INV. ELEV OUT H (VARIES) SHOWN ON PROFILE PIPE BEDDING OUTLET PIPE IN SIDE OR END WALL H (VARIES) STD VALLEY GUTTER SECTION BICYCLE AND PEDESTRIAN %%uSECTION THRU LENGTH A-A %%uSECTION THRU WIDTH B-B 6" 3" \A1;6" Y Y ALL DIMENSIONS ARE OUT-TO-OUT OF BAR. X 1' 1' X X 403 402 401 %%uBENDING DIAGRAM NOTES: CONCRETE SHALL BE CLASS B. INLET MAY BE CAST-IN-PLACE OR PRECAST. CAST-IN-PLACE CONCRETE WALLS SHALL BE FORMED ON BOTH SIDES. EXPOSED CONCRETE CORNERS SHALL BE CHAMFERED 3/4 IN. REINFORCING BARS SHALL BE DEFORMED AND SHALL HAVE A 2 IN. MINIUMUM CLEARANCE. STEPS SHALL BE PROVIDED WHEN INLET DIMENSION "H" EXCEEDS 3 FT. - 6 IN. AND SHALL BE IN ACCORDANCE WITH AASHTO M 199. ALL GRATES AND FRAMES SHALL BE GRAY OR DUCTILE CAST IRON CONFORMING TO CITY OF LOVELAND SPEC. 05500. GRATES AND FRAMES SHALL BE DESIGNED TO WITHSTAND HS 20 LOADING. ALL REINFORCING BARS SHALL BE NO. 4 BARS. DIMENSIONS FOR C.I.P. PRECAST WALLS & FLOOR THICKNESS ARE MINIMUM 6" STORM DRAIN MARKER TO BE PROVIDED BY THE CITY OF LOVELAND & INSTALLED PER DIRECTION OF THE CITY. INFORMATION FROM CDOT STANDARD PLAN M-604-13 IS REFERENCED IN THIS DETAIL. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10" TO 14" 6" 401 @ EQUAL SPACING AT 9"± \A1;B 403 @ 8" 403 O.C. @ 8" O.C. B A A 6'-3 1/2" 4' ℄ GUTTER TYPE 2 %%uPLAN OF TYPE 13 INLET FOR VALLEY GUTTER CAST GRATING (TYP.) Y SAFE GRATE AND FRAME BACK FILL WITH CLASS 67 GRANULAR MATERIAL HAND TAMPED IN 6" LIFTS. SLOPE FLOOR UNDISTURBED GROUND OR FIRM FOUNDATION MAT'L. 19 1 2" 63 1 2" 4'-0" 402 @ 8" O.C. 305 D4 INLET SCHEDULE INLET ID INLET TYPE A2 Triple Combination A3 Double Combination A6 Triple Combination B2 Single Area Inlet C3 Double Combination D3 Double Combination 307 INLET SCHEDULE D4 NOT TO SCALE RIPRAP SCHEDULE Storm Line/Culvert Label Riprap Type Length of Riprap (ft) Width of Riprap (ft) 2*d50, Depth of Riprap (ft) Storm A Type M 12.00 10.00 1.5 Storm B Type M 10.00 8.00 1.5 Storm C Type M 5.00 5.00 1.5 Storm D Type M 5.00 5.00 1.5 306 RIPRAP SCHEDULE D4 NOT TO SCALE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NOT TO SCALE 207 D3 STANDARD INTERIOR SETTING FOR 3/4 IN. AND 1 IN. WATER METERS ALL JUNCTION BOXES MUST BE INSTALLED NO MORE THAN 96 INCHES ABOVE THE FLOOR AND HAVE OPEN PROVIDE CLEAR AND UNOBSTRUCTED 2 FT. BY 2 FT. MINIMUM ACCESS TO THE COPPERHORN AND SHUTOFF (IF REQUIRED BY PLUMBING CODE) PRESSURE REDUCING VALVE METERS SHALL NOT BE INSTALLED IN CRAWL SPACES. JUNCTION BOXES SHALL NOT BE INSTALLED IN ATTICS OR CRAWL SPACES. A SECURE SUPPORT IS REQUIRED FOR COPPERHORNS. COPPERHORNS WILL BE INSTALLED SO THAT METERS ARE IN A HORIZONTAL POSITION. 5. 7. 6. 4. 3. 2. GENERAL NOTES: 1. STANDARD 2 IN. DEEP RECESSED (SUGGESTED METHOD) FOR WATER SERVICE LINES SUPPORT OR BRACING REQUIRED WATER SERVICE TO INLET AND OUTLET OF COPPERHORN SHUT-OFF VALVES WITH HANDLES ATTACHED (VERTICAL INSTALLATION RECOMMENDED) AND 48 IN. TO 66 IN. ABOVE FINAL GRADE MOUNT WITHIN 4 FT. OF ELECTRIC METER ELECTRIC BOX (SEE NOTES 2 & 3) 1/2 IN. OR LARGER ELECTRICAL CONDUIT (SEE NOTE 2) (SEE NOTE 4) COPPERHORN 3 IN. MIN. FROM WALL NOT TO SCALE 48 IN. MAX. FROM BASEMENT FLOOR SAME SIDE AS THE ELECTRIC METER AND TERMINATED WITHIN 6 INCHES OF THE COPPERHORN. NO FLEXIBLE ELECTRICAL CONDUIT WILL BE 1/2 INCH OR LARGER ELECTRICAL METALLIC TUBING ONLY, INSTALLED IN CONFORMANCE WITH ARTICLES 347 AND 348 OF THE CURRENT NATIONAL ELECTRIC CODE. CONDUIT MAY NOT EXTEND MORE THAN 75 FEET BETWEEN JUNCTION BOXES. CONDUIT WILL BE CONNECTED TO A RECESSED EXTERIOR ELECTRICAL BOX MOUNTED WITHIN 1 FOOT OF THE FRONT CORNER OF THE STRUCTURE ON THE VALVES. PVC CONDUIT ALLOWED. ACCESS. REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 STANDARD INTERIOR SETTING FOR 3/4 IN. AND 1 IN. WATER METERS 14 4/11/11 DO NOT INSTALL IN ANY STREET, ALLEY, PARKING AREA, DRIVEWAY, SIDEWALK, DRAINAGE DITCH OR DETENTION NO LANDSCAPING (SHRUBS, BOULDERS, ETC.) OR STRUCTURES TO BE WITHIN 4 FEET OF METER BOX, OR SLOPE GROUND SURROUNDING METER BOX AWAY FROM LID AT 2% MINIMUM GRADE. MAKE NO PLUMBING CONNECTIONS (TEES, COUPLINGS, ETC.) IN METER BOX. ALL TEES AND CONNECTION FITTINGS TO BE A MINIMUM OF 5 FEET FROM METER BOX WALL ON OUTLET SIDE. GRADE ACCEPTANCE AFTER METER BOX INSTALLATION REQUIRES THAT THE OWNER ADJUST METER BOX COVER TO 1/2 INCH ABOVE FINAL GRADE. IF A PRESSURE REDUCING VALVE IS REQUIRED BY PLUMBING CODE, INSTALL VALVE INSIDE THE BUILDING, IMMEDIATELY FOLLOWING THE MAIN SHUT-OFF VALVE. 1. 2. 3. 4. 5. 6. 7. 14 IN. MIN. ALLOWED CAST IRON FROST PROOF METER BOX COVER COMPRESSION TYPE CONNECTION LOCK TYPE INLET VALVE TYPE "K" COPPER PIPING 48 IN. 10 IN. INSTALL LID 1/2 INCH ABOVE FINAL LANDSCAPED GRADE FLOW METER BOX METER GENERAL NOTES 2 FT. MAX. CURB BOX 64 IN. (NO OR EXTENSIONS) ALTERATIONS CAST IRON RECESSED LID WITH WORM LOCK RUBBER OR PLASTIC INNER LID NO TREES WITHIN 10 FEET OF METER BOX. NO FOR FITTINGS MIN. OF 5 FT. 18 IN. MAX. ALLOWED 15 IN. RECOMMENDED C.L. OF METER CONNECTION 6 INCH LAYER OF GRAVEL (3/4 IN.- 1 1/2 IN.) UNDER METER BOX CURB STOP REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 STANDARD EXTERIOR SETTING FOR 3/4 IN. AND 1 IN. WATER METERS 15 4/11/11 BASIN. NOT TO SCALE 208 D3 STANDARD EXTERIOR SETTING FOR 3/4 IN. AND 1 IN. WATER METERS 6" CONNECTION COMPRESSION 8" LAYER OF 3/4" TO 1 1/2" GRAVEL SUPPORT METER SETTERS BY (2) 18 INCH LENGTHS OF 1 INCH IRON PIPE INSERTED THROUGH IF A PRESSURE REDUCING VALVE IS REQUIRED BY PLUMBING CODE, IT SHALL BE INSTALLED INSIDE THE BUILDING, GRADE ACCEPTANCE AFTER METER PIT INSTALLATION REQUIRES THAT THE OWNER ADJUST METER PIT COVER ALL TEES, COUPLINGS AND CONNECTION FITTINGS TO BE A MINIMUM OF 5 FEET FROM METER PIT WALL ON OUTLET NO LANDSCAPING (TREES, SHRUBS, BOULDERS, ETC.) OR RETAINING WALLS TO BE WITHIN 4 FEET OF METER PIT DO NOT INSTALL IN ANY STREET, ALLEY, PARKING AREA, DRIVEWAY, SIDEWALK, DRAINAGE DITCH OR DETENTION AND NO TREES WITHIN 10 FEET. BRACE PIPE EYELETS AND SET ATOP (4) 8 INCH SQUARE CONCRETE BLOCKS. IMMEDIATELY FOLLOWING THE MAIN SHUT-OFF VALVE. TO 1/2 INCH ABOVE LANDSCAPED FINAL GRADE. MAKE NO PLUMBING CONNECTIONS (TEES, COUPLINGS, ETC.) IN METER PIT. SLOPE GROUND SURROUNDING METER PIT AWAY FROM LID AT 2% GRADE OR GREATER. 9. 8. 7. 6. 5. 1. 3. 2. %%uGENERAL NOTES: 8" 12" (MIN.) PIPE BRACE 1" DIA. IRON (TYP.) 2' (MAX.) 2% SLOPE GRADE RINGS (IF REQUIRED) PRE-CAST CONCRETE BEFORE BACKFILLING AND GROUT KNOCKOUT ARMOUR-FLEX TUBING MANHOLE PRECAST CONCRETE CURB BOX (TYP. ALL JOINTS) PLASTIC GASKETS PRE-FORMED 1-1/2" METERS FLOW 2" METERS 17 1/4" FOR 13 1/4" FOR SETTER METER 12" O.C. MANHOLE RUNGS 48" ALUMINUM MANHOLE RING AND COVER WITH LOCK NUT 24" 54" (MIN.) 66" (MAX.) INSTALL LID 1/2 IN. ABOVE FINAL LANDSCAPED GRADE MASTIC MORTAR OR 16" (MAX.) 7" (MIN.) FINISHED GRADE AMR POD (FORD YOKE BOX PART #YUC-7 WITH FORD YOKE BOX LID PART #YL-TP WITH 1 27/32" DIA. HOLE AND REMOVABLE PLUG) 3" (MAX.) 1" (MAX.) 1/2" EMT OR PVC VAULT OR PIT TOP INTO YOKEBOX 2' (MAX.) 3/4" ROCK FOR GRADE ADJUSTMENT (IF REQ'D) 12" (MIN.) (MAX.) (TYP.) TOP OF AMR LID TO BE 1/2" ABOVE FINISHED GRADE CONDUIT THROUGH 10. A SEPERATE AMR POD MUST BE INSTALLED FOR EACH METER REGISTER. 4. THE METER PIT AND AMR POD(S) MUST REMAIN OPEN AND ACCESSABLE FOR METER READING AND MAINTENANCE. CURB STOP REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 STANDARD SETTING FOR 1-1/2 IN. AND 2 IN. WATER METERS 16A 4/11/11 SIDE. BASIN. NOT TO SCALE 209 D3 STANDARD SETTING FOR 1-1/2 IN. AND 2 IN. WATER METERS NOT TO SCALE 210 D3 STANDARD SETTING FOR 1-1/2 IN. AND 2 IN. WATER METERS (PLAN VIEW) %%UPLAN 48" DIA. VIEW BEFORE BACKFILLING ARMOUR-FLEX TUBING AND GROUT KNOCKOUT BOX CURB FLOW 2' (MAX.) 1" DIA. IRON (TYP) PIPE BRACE MANHOLE RUNGS BELOW LID) METER (PLACED 12" O.C. 24" DIA. PRECAST CONCRETE MANHOLE 8" x 8" CONCRETE BLOCK (TYP.) AND REMOVABLE PLUG) WITH 1 27/32" DIA. HOLE YOKE BOX LID PART #YL-TP PART #YUC-7 WITH FORD AMR POD (FORD YOKE BOX %%uGENERAL NOTES: 1. LOCATION AND ALIGNMENT OF AMR POD ON PIT TOP CAN VARY. 2. SEE DETAIL 16-A FOR ADDITIONAL METER PIT INFORMATION. REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 STANDARD SETTING FOR 1 1/2 IN. AND 2 IN. WATER METERS (PLAN VIEW) 16B 4/11/11 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NOT TO SCALE 200 D2 WATER MAIN BEDDING REQUIREMENTS BOTTOM OF PIPE AND A MINIMUM OF 12 INCHES ABOVE TOP OF PIPE. GRANULAR BEDDING MATERIAL SHALL BE A MINIMUM OF 4 INCHES BELOW INITIAL 12 IN. LIFT MIN. PIPE O.D. 4 IN. MIN. GRANULAR MATERIAL BEDDING ZONE %%UNOTE: * INITIAL LIFT SHALL NOT EXCEED 2 FEET IN DEPTH. TRENCH WALL LOWER LIMIT OF SLOPING TRENCH IN WIDTH SECTION AS 02221 SPECIFIED * REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 WATER MAIN BEDDING REQUIREMENTS (DIP & PVC) 1 4/8/11 NOT TO SCALE 201 D2 STANDARD CONCRETE THRUST BLOCKS PIPE SIZE BENDS TEE OR DEAD END 22 1/2%%D 45%%D 90%%D 6" 8" 12" 1.0 1.5 3.0 1.5 2.5 4.5 2.5 4.5 9.0 4.5 8.0 16.5 3.5 5.5 12.0 MINIMUM BEARING SURFACE AREA (SQ. FT.) Bearing surface areas shown in chart are minimum. All fittings to be wrapped with polyethylene. Pipe installed under conditions different from those normally encountered shall require thrust blocks designed for those particular conditions. Thrust blocks on pipe larger than 16 inches diameter shall be designed for conditions existing at the installation site. Refer to Section 03300 for concrete requirements. 1. 2. 3. 4. 5. GENERAL NOTES: UNDISTURBED SOIL POLYETHYLENE BOND BREAKER UNDISTURBED SOIL BOND BREAKER POLYETHYLENE BEARING SURFACE POLYETHYLENE BOND BREAKER UNDISTURBED SOIL BEARING SURFACE SOIL UNDISTURBED BEARING SURFACE POLYETHYLENE BOND BREAKER BEDDING MATERIAL 2/3 DIA. %%UTEE %%UTYPICAL BEND %%UTYPICAL CROSS-SECTION %%UDEAD END BEARING SURFACES ARE A MINIMUM REQUIREMENT AND DO NOT RELIEVE DESIGN ENGINEER OF RESPONSIBILITY TO DESIGN EACH THRUST BLOCK. 16" 4.8 9.6 18.9 34.7 24.5 REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 STANDARD CONCRETE THRUST BLOCKS 2 4/8/11 FIRE HYDRANT PIPING, VALVES, ETC. SHALL BE WRAPPED IN WALLS OR FENCES ALLOWED WITHIN 4 FEET OF FIRE HYDRANT. NO LANDSCAPING (TREES, SCRUBS, BOULDERS, ETC.), RETAINING GATE VALVE RESILIENT SEAT POLYETHYLENE 8 MIL SHEET OF MUST REMAIN CLEAR OF 24 INCH MIN. CONCRETE BLOCK (REF. SECTION 02644) THRUST BLOCK 12 IN. POLYETHYLENE. JOINTS RESTRAINED (REF. SECTION 02644) HYDRANT GRAVEL 6 INCH DIA. PIPE OBSTRUCTIONS %%UNOTES 18 IN. 0.1 FT.-0.2 FT. FLOW-FILL 12 IN. OR BACK OF CURB EDGE OF SIDEWALK HYDRANT DRAIN OPENINGS MINIMUM 30 INCHES 66 INCHES 54 INCHES MAXIMUM MINIMUM LOCATOR STATION (SEE DETAIL 25) WATROUS PACER 250 NUMBER A-423 OR MUELLER HYDRANT 22 IN. 18 IN. to THRUST BLOCK SWIVEL TEE SECTION 02641) MAIN ONLY) (PVC WATER TRACER WIRE (REFERENCE VALVE BOX REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 FIRE HYDRANT INSTALLATION 3 4/8/11 NOT TO SCALE 202 D2 FIRE HYDRANT INSTALLATION RETAINER GLANDS INSTALL MEG-A-LUG SEE DETAIL 2 FOR THRUST BLOCK SIZING. AS APPLICABLE. SECTION 02615-2.6A OR SECTION 02622-2.2A ALL D.I.P. PIP AND FITTINGS SHALL BE WRAPPED ALL FITTINGS AND JOINTS IN LOWERING AREA SEE DETAIL 4B FOR GRAVITY BLOCK SIZING. WITH POLYETHYLENE ENCASEMENT. TO BE RESTRAINED IN ACCORDANCE WITH GENERAL NOTES: 4. 3. 2. 1. 49"-66" >66" 25"-48" 4"-24" D UTILITY BEING CROSSED THRUST GRAVITY BLOCK (TYP.) ANCHOR (TYP.) SEE DETAIL 4B SEE DETAIL 2 L (ft) (Typ) 18 IN. MIN. D L (ft) STREET GRADE 7' 10' 5' 3' L(ft) WATER MAIN PROPOSED (TYP.) REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 WATER MAIN LOWERING 4A 4/11/11 NOT TO SCALE 203 D2 WATER MAIN LOWERING WATER MAIN SIZE (INCHES) BENDS 45%%D 22 1/2%%D 6 8 10 TRENCH BOTTOM REINFORCING BAR (SEE TABLE) 16 14 12 4 CONCRETE GRAVITY 3 (FT. ) BLOCK VOLUME (FT. 3 ) (FT. 3 ) 15.9 35.3 62.4 8.6 19.1 33.8 4.4 9.7 17.2 95.4 136.4 184.7 51.6 73.8 100.0 26.3 37.6 51.0 240.9 130.4 66.5 LESS THAN 60CF 90CF 200CF 133CF 400CF 600CF NO. OF BARS & SIZE 2 2 2 2 2 3 1/2 IN. 5/8 IN. 3/4 IN. BAR SIZES FOR 150 P.S.I. RESTRAIN ALL FITTINGS AND JOINTS. VOLUMES SHOWN IN TABLE ARE BASED ON 150 P.S.I. INTERNAL STATIC PRESSURE. VALUES FOR ANY PRESSURE MAY BE OBTAINED BY MULTIPLYING TABULATED VALUES BY A CORRECTION FACTOR "F". "F" = (REQUIRED FOR VERTICAL BEND GRAVITY ANCHORS FOR 150 P.S.I. PRESSURE). NOTE: ACTUAL PRESSURE 150 %%UGRAVITY ANCHOR DETAIL REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 WATER MAIN LOWERING GRAVITY BLOCKS 4B 4/11/11 NOT TO SCALE 204 D2 WATER MAIN LOWERING GRAVITY BLOCKS All residential water service shall be installed in the center of the lot All water and sanitary sewer service shall have a minimum of the curb stop and meter pit, and no trees within 10 feet of curb and meter pit. No landscaping (shrubs, boulders, etc.), retaining walls or fences allowed within 4 feet Use type K copper for the service from the corporation stop to a minimum of 5 feet up to and including the curb stop. The owner is responsible for service from the The City is responsible for maintaining the water main, corporation stop, and service piping Locate curb box and meter pit according to the approved utility drawings. Install 1 1/2 inch and 2 inch services with tapped tee and corporation stop at time of Use direct tap (as shown) for 3/4 inch and 1 inch services unless water main is PVC, unless otherwise approved by the Utility. horizontal separation of ten feet. No couplings allowed between curb stop and meter setting. curb stop, including the outlet coupling to the building. construction or use a tapping saddle. in which case, use a tapping saddle. GENERAL NOTES 9. 8. 4. 6. 7. 5. WATER MAIN 3. 2. 1. IN FACE OF CURB CUT 4 INCH CROSS CORPORATION STOP FOR PAVEMENT CURB STOP CURB BOX 66 INCH MAX. 54 INCH MIN. CURB, GUTTER AND SIDEWALK DISTANCE VARIES 1 FT. PROPERTY OR EASEMENT LINE GRADE FINAL LANDSCAPED REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 TYPICAL WATER SERVICE 11 4/12/11 1 1/2 INCH OR GREATER CORPORATION STOP FOR 3/4 AND 1 INCH SERVICES SERVICES 1 INCH SERVICES NOT TO SCALE 205 D2 TYPICAL WATER SERVICE WET UTILITY SERVICE TABLE TAP & METER SIZE SUPPLY LINE SIZE FIRE SANITARY SEWER 32-UNIT BUILDINGS 2" 2" 6" 6" 28-UNIT BUILDINGS 2" 2" 6" 6" TOWNHOME 3/4" - - 4" CLUBHOUSE 1" 1.25" 6" 4" POOL - - - TBD IRRIGATION 1.5" - - - 206 SERVICE SCHEDULE D2 NOT TO SCALE WATERLINE LOWERING ELEVATIONS # CROSSING DESCRIPTION 1 2 3 4 D T A STORM DRAIN A AND CUTTING HORSE DRIVE 4891.01 4888.43 4888.43 4891.01 24" 2.6 B STORM DRAIN C AND PRIVATE DRIVE 4886.41 4884.92 4884.92 4886.41 15" 1.5 C STORM DRAIN C AND LUSITANO LANE 4886.01 4885.45 4885.45 4885.84 15" 0.6 D STORM DRAIN D AND PRIVATE DRIVE 4884.80 4884.25 4884.25 4884.8 15" 0.6 1 2 3 4 T (ft) CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R COMPACTED GRANULAR MATERIAL CONFORMING TO CDDH #67 LOWER LIMIT OF TRENCH WALL SLOPING INITIAL LIFT * 12 IN. MIN. PIPE O.D. 4 IN. MIN. TRENCH WIDTH AS SPECIFIED IN SECTION 02221 COMPACTED GRANULAR MATERIAL CONFORMING TO CDDH #67 * DATE REVISED: SEWER CONSTRUCTION DETAILS APPROVED: DRAWN BY: DETAIL BEDDING REQUIRMENTS WW-1 NBJ 4/11/11 NOT TO SCALE 100 D1 BEDDING REQUIREMENTS STANDARD MANHOLE SERVICE WYE DETAIL ALTERNATE BASE POURED INVERT PRECAST MANHOLE BASE 2 IN. MIN. SLOPE 1 IN. MIN. 8 IN. MIN. 6 IN. 15 IN. OR LESS 48 IN. 18 IN. TO 30 IN. 60 IN. OVER 30 INCHES 72 IN. MIN. MANHOLE MINIMUM INSIDE DIAMETER OF DIAMETER MANHOLE SHALL BE AS FOLLOWS: PIPE SIZE 5 FT. MIN. DEPTH CONCRETE ADJUSTMENT SHIMS GROUTED INSIDE ASTM C-478 ECCENTRIC CONE PRE-FORMED PLASTIC GASKET ASTM C-478 MANHOLE SECTIONS GROUT BASE TO BARREL SECTION ON INSIDE PRE-FORMED PLASTIC GASKET CAST-IN-PLACE CONCRETE BASE 16 IN. MAX. FINISHED GRADE 30 IN. MIN. 48 IN. MAX. VARIABLE 28 IN. MAX. 24 IN. SEE TABLE 6 IN. 12 IN. SLOPE 1 IN./FT. 18 IN. MAX. MANHOLE RUNGS 12 IN. O.C. 8 IN. MIN DATE REVISED: SEWER CONSTRUCTION DETAILS APPROVED: DRAWN BY: DETAIL STANDARD MANHOLE WW-3 NBJ 4/11/11 PLAN VIEW CROSS VIEW 45 ELBOW SERVICE WYE 8 IN. PVC SEWER PIPE COMPACTED GRANULAR MATERIAL AIR-TIGHT PLUG WITH 4 IN. X 4 IN. MARKER UNYIELDING PIPE BEDDING OF COMPACTED ROCK OR LEAN CONCRETE PVC SEWER PIPE NOTE: WYE CONNECTION NOT ALLOWED ON VCP LEAN CONCRETE o 20 MIN. o 45 MAX. o TRENCH UNYIELDING PIPE BEDDING OF COMPACTED ROCK OR 4 IN. X 4 IN. MARKER AIR-TIGHT PLUG DATE REVISED: SEWER CONSTRUCTION DETAILS APPROVED: DRAWN BY: DETAIL SERVICE WYE DETAIL WW-9 NBJ 4/11/11 SERVICE CLEANOUT REQUIREMENTS 2. 3. 1. SLOPE TO MATCH SRV. GRADE AS REQ'D TRAFFIC/PAVED AREAS NTS 6" PVC PIPE CUT TO MATE w/ BELL FLOW CONTINUATION OF SEWER LINE COUPLING SRV. PIPE 4"-45%%D 6"ELBOW x6"x4" VARIES COMPACTED GRANULAR 4" PVC SDR 35 PIPE & FITTINGS (TYP.) FROM BOTTOM OF BEDDING ZONE TO TOP OF ELBOW MATERIAL PVC SLIP VALVE BOX AND COVER W/ "SEWER" CAST INTO COVER SCREW-ON WATER TIGHT PLUG 4. 2'x2'x6" DEEP SEWER SERVICE CLEANOUTS SHALL BE INSTALLED AS NEAR AS PRACTICAL TO BUILDING CONNECTION, AT ALL BEND COMBINATIONS GREATER THAN 45%%D AND AT A MAXIMUM SPACING OF 100'. NO SINGLE BEND GREATER THAN 45%%D SHALL BE ALLOWED. CONCRETE COLLAR CLEANOUTS SHALL MEET ALL REQUIREMENTS OF THE UNIFORM PLUMBING CODE. FERNCO OR CAULDER COUPLINGS SHALL NOT BE ALLOWED AT SPLICES, UNLESS EXIST. SEWER SERVICE IS CLAY. CLEANOUT SHALL BE CONSTRUCTED SO THAT SURFACE LOAD WILL NOT BE TRANSFERRED TO MAIN ELBOW COMPACTED GRANULAR 4"-45%%D 6"x6"x4" SRV. GRADE AS REQ'D w/ BELL CUT SRV. TO MATE PIPE VARIES PIPE 6" PVC FLOW SLOPE TO MATCH MATERIAL TOP OF ELBOW BEDDING ZONE TO FROM BOTTOM OF & FITTINGS (TYP.) 4" PVC SDR 35 PIPE OVER CLEANOUT PVC COUPLING SLIP OF SEWER LINE CONTINUATION ACCESS COVER HEAVY-DUTY FINISHED GRADE LANDSCAPED AREAS NTS 6" MIN. SANITARY SEWER CLEANOUT NOT TO SCALE 101 D1 102 D1 103 D1 WET UTILITY SERVICE TABLE TAP & METER SIZE SUPPLY LINE SIZE FIRE SANITARY SEWER 32-UNIT BUILDINGS 2" 2" 6" 6" 28-UNIT BUILDINGS 2" 2" 6" 6" TOWNHOME 3/4" - - 4" CLUBHOUSE 1" 1.25" 6" 4" POOL - - - TBD IRRIGATION 1.5" - - - 104 SERVICE SCHEDULE D2 NOT TO SCALE - Filing Four EC2 EROSION CONTROL DETAILS A. Reese L. Seeber 1"=50' CONCRETE WASHOUT AREA VEHICLE CONTROL TRACKING PAD CURB INLET PROTECTION NOT TO SCALE 4 EC2 3 EC2 1 EC2 ROCK SOCK DETAIL NOT TO SCALE 2 EC2 0" ON BEDROCK OR HARD SURFACE, 2" IN SOIL ROCK SOCK SECTION ROCK SOCK PLAN 4" TO 6" MAX AT CURBS, OTHERWISE 6"-10" DEPENDING ON EXPECTED SEDIMENT LOADS ROCK SOCK JOINTING \A1;12" \A1;12" {ROCK SOCK INSTALLATION NOTES }1.SEE PLAN VIEW FOR: - LOCATION (S) OF ROCK SOCKS. 2.CRUSHED ROCK SHALL BE 1{}" (MINUS) IN SIZE WITH A FRACTURED FACE (ALL SIDES) AND SHALL COMPLY WITH GRADATION SHOWN ON THIS SHEET (1{}" MINUS). 3.WIRE MESH SHALL BE FABRICATED OF 10 GAGE POULTRY MESH, OR EQUIVALENT, WITH A MAXIMUM OPENING OF {}", RECOMMENDED MINIMUM ROLL WIDTH OF 48". 4.WIRE MESH SHALL BE SECURED USING "HOG RINGS" OR WIRE TIES AT 6" CENTERS ALONG ALL JOINTS AND AT 2" CENTERS ON ENDS OF SOCKS. 5.SOME MUNICIPALITIES MAY ALLOW THE USE OF FILTER FABRIC AS AN ALTERNATIVE TO WIRE MESH FOR THE ROCK ENCLOSURE. GRADATION TABLE SIEVE SIZE MASS PERCENT PASSING SQUARE MESH SIEVES NO. 4 2" 100 1-1/2" 90-100 1" 20-55 3/4" 0-15 3/8" 0-5 MATCHES SPECIFICATIONS FOR NO. 4 COARSE AGGREGATE FOR CONCRETE PER AASHTO M43. ALL ROCK SHALL BE FRACTURED FACE, ALL SIDES RS VEHICLE TRACKING CONTROL PAD SHALL BE LOCATED AT EVERY ACCESS POINT TO THE CONSTRUCTION SITE. A SIGN SHALL BE PLACED NEXT TO THE VEHICLE TRACKING CONTROL PAD TO DESIGNATE THE LOCATION AS THE CONSTRUCTION ENTRANCE/EXIT. VEHICLE TRACKING CONTROL PADS SHALL CONSIST OF HARD, DENSE, DURABLE STONE, ANGULAR IN SHAPE AND RESISTANT TO WEATHERING. ROUNDED STONE (i.e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x4'S, PIPES, DIRT, GRAVEL OR ASPHALT, SHALL BE PLACED IN GUTTER TO FACILITATE MOUNTING CURB; HOWEVER, CURB MAY BE CUT DOWN TO A HEIGHT OF 2" OR HIGHER FOR EASIER ACCESS AND REPLACED AT PROJECT COMPLETION. OTHER ACCESS DEVICES MAY BE USED AS ACCEPTED BY THE CITY. 3" - 6" ROCK CURB CUT 50' MIN. 2" MIN. 6" MIN. 6" MIN. ALTHOUGH NOT NORMALLY USED, THE CITY RESERVES THE RIGHT TO REQUIRE VEHICLE TRACKING CONTROL WITH A TEMPORARY CATTLE GUARD AND/OR WHEEL WASH FACILITIES AT SITES WHERE TRACKING ONTO PAVED AREAS BECOMES A SIGNIFICANT PROBLEM AS DETERMINED BY THE CITY INSPECTOR. IF VEHICLE TRACKING CONTROL WITH WHEEL WASH FACILITIES ARE REQUIRED, ALL WHEELS ON EVERY VEHICLE LEAVING THE SITE SHALL BE CLEANED OF MUD USING A PRESSURE-WASHER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A WATER SOURCE AND CONSTRUCTING A WASHWATER SEDIMENT TRAP. 5. 6. IF VEHICLE WHEEL WASH FACILITIES ARE REQUIRED, CONTRACTOR SHALL INSPECT VEHICLE TRACKING CONTROL AND WHEEL WASH FACILITIES DAILY. ACCUMULATED SEDIMENTS SHALL BE REMOVED FROM THE PAD SURFACE. ACCUMULATED SEDIMENT IN THE WASHWATER/SEDIMENT TRAP SHALL BE REMOVED WHEN THE SEDIMENT REACHES AN AVERAGE DEPTH OF 12-INCHES. 4. 5. VTC CONCRETE WASHOUT AREA SHALL BE INSTALLED PRIOR TO ANY CONCRETE PLACEMENT ON SITE. VEHICLE TRACKING CONTROL IS REQUIRED IF ACCESS TO CONCRETE WASHOUT AREA IS OFF PAVEMENT. SIGNS SHALL BE PLACED AT THE CONSTRUCTION ENTRANCE, AT THE WASHOUT AREA, AND ELSEWHERE AS NECESSARY TO CLEARLY INDICATE THE LOCATION OF THE CONCRETE WASHOUT AREA TO OPERATORS OF CONCRETE TRUCKS AND PUMP RIGS. THE CONCRETE WASHOUT AREA SHALL BE REPAIRED AND ENLARGED OR CLEANED OUT AS NECESSARY TO MAINTAIN CAPACITY FOR WASTED CONCRETE. AT THE END OF CONSTRUCTION, ALL CONCRETE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF AT AN ACCEPTED WASTE SITE. WHEN THE CONCRETE WASHOUT AREA IS REMOVED, THE DISTURBED AREA SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED IN A MANNER ACCEPTED BY THE CITY. LOCATION OF CONCRETE WASHOUT AREA ON SHEET EC1 IS CONCEPTUAL ONLY. FINAL LOCATION TO BE DETERMINED IN THE FIELD AT CONTRACTOR'S DISCRETION. {NOTES: }1. 2. 3. 4. 5. 6. 7. 3H:1V OR FLATTER SIDE SLOPES \A1;12" MIN 8'x 8' MIN OR AS REQUIRED TO CONTAIN WASTE CONCRETE \A1;12" \A1;2'-0" MIN. COMPACTED EMBANKMENT MATERIAL, TYP. BERM AROUND PERIMETER GROUND SURFACE SIGN TO INDICATE THE LOCATION OF THE CONCRETE WASHOUT AREA CWA MANHOLE ROCK BERM SHALL 2"x 4" WOOD STUD EXTENDED INTO CONCRETE BLOCKS WIRE ENCLOSED 1 1/2" WASHED ROCK CONCRETE BLOCKS CURB INLET GRAVEL FILTER WIRE SHALL ENCLOSED BE 2"x4" WOOD STUD OVERFLOW FILTERED RUNOFF %%uSECTION A-A A A %%uPLAN VIEW {CURB INLET GRAVEL FILTER (CONTINUOUS GRADE)} %%uSECTION B-B %%uPLAN VIEW B B ROCK BERM SHALL BE PLACED TIGHTLY AGAINST CURB FACE WIRE ENCLOSED 1 1/2" WASHED ROCK CURB AND GUTTER CURB AND GUTTER BE PLACED TIGHTLY AGAINST CURB FACE GRAVEL FILTER 1/2" TO 1" BELOW TOP OF CURB TUBULAR MARKER IF AREA ADJACENT TO CURB INLET BOX IS NOT STABILIZED, INSTALL A TEMPORARY SEDIMENT/EROSION CONTROL BMP UNTIL THE SURROUNDING AREA IS SUFFICIENTLY STABILIZED. TUBULAR MARKER TUBULAR MARKER \A1;3' \A1;2' CURB INLET WIRE ENCLOSED SETTLED RUNOFF GRAVEL FILTER CURB INLET MANHOLE {CURB INLET BLOCK AND GRAVEL FILTER (INLET IN SUMP)} INTERIM CONFIGURATION INLET PROTECTION IN STREETS SHALL BE INSTALLED WITHIN 48 HOURS OF POURING INLET. INLET PROTECTION (AFTER PAVING) SHALL BE INSTALLED WITHIN 48 HOURS AFTER PAVING IS PLACED. WASHED ROCK SHALL COMPLY WITH A 1-1/2" MINUS GRADATION. WIRE MESH SHALL BE FABRICATED OF 10 GAUGE WIRE TWISTED INTO A MESH WITH A MAXIMUM OPENING OF 1" (COMMONLY TERMED "CHICKEN WIRE"). ROLL WIDTH SHALL BE 48". TUBULAR MARKERS SHALL MEET REQUIREMENTS OF MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). OTHER CURB INLET PROTECTION METHODS WILL BE ALLOWED IF ACCEPTED BY THE CITY. {GENERAL NOTES: }1. 2. 3. 4. 5. THE CONTRACTOR SHALL INSPECT INLET PROTECTION EVERY TWO WEEKS AND AFTER SIGNIFICANT STORM EVENTS AND MAKE REPAIRS OR CLEAN OUT AS NECESSARY. SEDIMENT ACCUMULATED UPSTREAM OF INLET PROTECTION SHALL BE REMOVED WHEN THE SEDIMENT DEPTH UPSTREAM OF ROCK BERM IS 2 1/2" OF THE CREST. INLET PROTECTION IS TO REMAIN IN PLACE UNTIL THE UPSTREAM DISTURBED AREA IS STABILIZED AND GRASS COVER IS ACCEPTED. UNLESS THE CITY ACCEPTS EARLIER REMOVAL OF INLET PROTECTION IN STREETS. {MAINTENANCE NOTES: }1. 2. 3. 4" MIN 5" MAX \A1;BMP WIDTH VARIES \A1;BMP WIDTH VARIES \A1;BMP WIDTH VARIES \A1;BMP WIDTH VARIES TUBULAR MARKER TUBULAR MARKER IP GM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM EM GM EM GM X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF FDC FDC FDC FDC FDC FDC FDC FDC FDC FDC FDC FDC FDC FDC NANCY GRAY AVENUE (76' PUBLIC ROW) GOOSEBERRY LANE (51' PUBLIC ROW) BLUE YONDER WAY (51' PUBLIC ROW) YEARLING ROAD (51' PUBLIC ROW) CUTTING HORSE DRIVE (51' PUBLIC ROW) MILES HOUSE AVENUE (PRIVATE DRIVE) LUSITANO LANE (PRIVATE DRIVE) CALABRESE STREET (PRIVATE DRIVE) CALABRESE STREET (PRIVATE DRIVE) ANDALUSIAN STREET (PRIVATE DRIVE) LUSITANO LANE (PRIVATE DRIVE) IP IP IP IP IP IP IP IP IP IP IP IP SW SW SW SW SW SW SW RS RS RS RS RS RS RS RS RS RS RS RS VTC CWA SF SF SF SF SF SF SF SF SF SF IP IP IP IP IP IP IP IP IP IP NORTH ( IN FEET ) 1 inch = ft. 30 0 30 Feet 30 60 90 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner BENCHMARK/BASIS OF BEARING LEGEND: 5013 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPOSED STORM INLET PROPOSED CONCRETE CROSS PAN (TYP.) PEDESTRIAN ACCESS RAMPS PROPERTY BOUNDARY SILT FENCE SF INLET PROTECTION IP ROCK SOCK RS VEHICLE TRACKING PAD VTC SF CONCRETE WASHOUT AREA CWA NOTE: ALL BMP'S SHOWN ON THIS PLAN ARE GRAPHIC REPRESENTATIONS ONLY. FINAL DETERMINATION OF SIZE AND LOCATION SHALL BE DETERMINED BY THE CONTRACTOR AND DOCUMENTED ON THE DYNAMIC SITE PLAN. FIELD SURVEY BY: GENERAL NOTES: NORTHERN ENGINEERING SERVICES, INC. PROJECT NO. 687-004 DATE: OCTOBER 28, 2013 PROJECT DATUM: NGVD 29 Unadjusted (Old City of Fort Collins Datum) City of Fort Collins Benchmark 4-07 Southwest corner of Timberline Rd. and Bear Mountain Dr. due north of new police building on the southwest corner of a catch basin Elevation = 4939.66 City of Fort Collins Benchmark 17-92 300 feet south of the southwest corner of East Drake Rd. and Timberline Rd. in the top of an irrigation structure. Elevation = 4935.51 Note: IF NACD 88 Datum is required for any purpose, the following equations should be used: NAVD 88 = NGVD 29 UNADJUSTED + 3.18' (FOR BM 4-07) NAVD 88 = NGVD 29 UNADJUSTED + 3.19' (FOR BM 17-92) BASIS OF BEARING The Northeast line of Tract M, Bucking Horse Filing One as bearing South 49° 38' 07" East (assumed bearing). 1. CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BY CRIMP MULCHING OR SIMILAR METHODS (AS APPLICABLE). 2. TOTAL DISTURBED AREA = 2.80 ACRES 3. SWMP ADMINISTRATOR: Contact ________________________________ Company ________________________________ Address ________________________________ Phone________________________________ 4. CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE WASHOUT AREA IF ACCESS IS OFF PAVEMENT. 5. REFER TO THE SEE SEPARATE FINAL DRAINAGE REPORT FOR BUCKING HORSE APARTMENTS, DATED MAY 11, 2016FOR ADDITIONAL INFORMATION. PLANTED RIPRAP PROTECTION RP PERMANENT BMP'S TEMPORARY BMP'S EROSION CONTROL FABRIC EF No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Drng\687-004_EROS.dwg LAYOUT NAME: EC1 DATE: May 10, 2016 - 3:29pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xUTIL] [687-004_xADJ] [687-004_xEXST] [687-004_xGRAD] [687-004_xSITE] [687-004_xTOPO] [NES-xborder] [687-004_3D_Proposed] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four EC1 (STATIC SITE PLAN) EROSION CONTROL PLAN A. Reese L. Seeber 1"=50' 1. IT SHOULD BE NOTED THAT ANY EROSION CONTROL PLAN SERVES ONLY AS A GUIDELINE TO THE CONTRACTOR. STAGING AND/OR PHASING OF BEST MANAGEMENT PRACTICES (BMPs) IS EXPECTED. ADDITIONAL AND/OR DIFFERENT BMPs FROM THOSE ORIGINALLY DEPICTED MAY BE NECESSARY DURING CONSTRUCTION DUE TO CHANGING SITE CONDITIONS OR AS REQUIRED BY LOCAL AUTHORITIES. 2. THIS EROSION CONTROL PLAN IS SCHEMATIC IN NATURE. AS SUCH, GRAPHICAL SYMBOLS MAY NOT BE TO SCALE, NOR ARE THEY NECESSARILY SHOWN IN THEIR EXACT LOCATION. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITTING (CITY, STATE DISCHARGE PERMIT, ETC.) AND COMPLIANCE WITH GOVERNING AUTHORITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR (OR PERMIT HOLDER) TO ENSURE EROSION CONTROL MEASURES ARE PROPERLY MAINTAINED AND FOLLOWED. 4. CONTRACTOR SHALL IMPLEMENT THE APPROPRIATE EROSION CONTROL MEASURES ACCORDING THE THE CONSTRUCTION SEQUENCING AND LEVEL OF SITE STABILIZATION. 5. CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR ALL STORM DRAINS, SWALES, PONDS AND RAIN GARDENS UNTIL SITE IS FULLY STABILIZED. 6. CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR DOWNSPOUT CONNECTIONS, TO THE STORM DRAIN SYSTEM, UNTIL CONNECTION IS ESTABLISHED WITH DOWNSPOUT. 7. INLET PROTECTION SHALL BE ADAPTED, AS NECESSARY, TO THE SURROUNDING SURFACE TYPE AND CONDITION (i.e., STAKE-DRIVEN WATTLES FOR BARE SOIL, SAND BAGS OR GRAVEL SOCKS FOR PAVEMENT, ETC.) 8. CONTRACTOR IS RESPONSIBLE FOR STABILIZING ALL SLOPES, PARTICULARLY THOSE STEEPER THAN 6:1. CRIMP MULCHING, HYDRO MULCHING, EROSION MATS, TEMPORARY IRRIGATION, AND ADDITIONAL WATTLES OR SILT FENCING MAY BE NECESSARY TO ESTABLISH VEGETATIVE COVER AND STABILIZE THE SLOPE. 9. ADDITIONAL WATTLES, SILT FENCE, OR OTHER MEASURES, MAY BE NECESSARY TO INSURE THAT EACH BUILDING PAD IS STABILIZED THROUGHOUT CONSTRUCTION. AT NO TIME SHALL SEDIMENT BE ALLOWED TO CROSS THE PUBLIC SIDEWALKS. 10. CONTRACTOR SHALL IMPLEMENT APPROPRIATE PERIMETER PROTECTION FOR AREAS DIRECTING DRAINAGE OFFSITE. PERIMETER PROTECTION SHALL BE ADAPTED, AS NECESSARY, TO THE SURROUNDING SURFACE TYPE AND CONDITION (i.e., STAKE-DRIVEN SEDIMENT CONTROL LOGS OR SILT FENCE FOR BARE SOIL, SAND BAGS OR GRAVEL SOCKS FOR PAVEMENT, ETC.) 11. FUELING FACILITIES SHALL BE LOCATED AT LEAST ONE HUNDRED (100) FEET FROM NATURAL BODY OF WATER, WETLAND, NATURAL DRAINAGE WAY OR MANMADE DRAINAGE WAY. THE FUEL TANKS AND FUELING AREA MUST BE SET IN A CONTAINMENT AREA THAT WILL NOT ALLOW A FUEL SPILL TO DIRECTLY FLOW, SEEP, RUN OFF, OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE WAY. 12. CONSTRUCTION WASTE STORAGE (DUMPSTERS) AND PORTABLE SANITATION UNITS (CONSTRUCTION TOILETS) SHALL BE LOCATED AT LEAST FIFTY (50) FEET FROM ANY STORMWATER INLET, WETLAND, OR DRAINAGE WAY. SAID FACILITIES MUST BE SET IN A CONTAINMENT AREA THAT WILL NOT ALLOW POLLUTANTS TO DIRECTLY FLOW, SEEP, RUN OFF, OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE WAY. DUMPSTERS SHALL BE LOCATED ON FLAT, STABLE GROUND, AND CONSTRUCTION TOILETS SHALL BE STAKED DOWN. 13. THE CONTRACTOR AND ALL SUBCONTRACTORS WILL COOPERATE WITH THE CITY'S CONSTRUCTION INSPECTORS BY CEASING OPERATIONS WHEN WINDS ARE OF SUFFICIENT VELOCITY TO CREATE BLOWING DUST WHICH, IN THE INSPECTOR'S OPINION, IS HAZARDOUS TO THE PUBLIC HEALTH AND WELFARE. 14. WHERE SEASONAL CONSTRAINTS (E.G., DURING SUMMER AND WINTER MONTHS) INHIBIT PERMANENT SEEDING OPERATIONS, DISTURBED AREAS WILL BE TREATED WITH MULCH AND MULCH TACKIFIER OR OTHER MATERIALS APPROVED BY EROSION CONTROL STAFF TO PREVENT EROSION. 15. SEE LANDSCAPE PLANS FOR ADDITIONAL INFORMATION ON PLANTING, REVEGETATION, HARDSCAPE AND OTHER PERMANENT SITE STABILIZATION METHODS. EROSION CONTROL NOTES: TABLE OF CONSTRUCTION SEQUENCE AND BMP APPLICATION CONSTRUCTION PHASE (DESCRIPTION) PHASE I (GRADING) PHASE II (INFRASTRUCTURE) PHASE III (VERTICAL CONSTRUCITON) PHASE IV (PERMANENT BMP'S) Grading (Include Offsite) Overlot Pipeline Installation Stormwater Concrete Installation Site Walls Building Structure Miscellaneous Hardscape Amenities BEST MANAGEMENT PRACTICES Temporary Inlet Protection (IP) Vehicle Tracking Control (VTC) Flow Barriers (Wattles, Rock Socks, etc.) (RS) Concrete Washout Area (CWA) Preventative Maintenance Activities/Meetings/etc. Silt Fence (SF) Permanent Mulching/Sealant Permanent Seed Planting Sewer Service Water Service Curb and Gutter Rip Rap (RP) Erosion Control Fabric (EF) TF TF TF TF TF TF TF TF TF TF TF TF TF EM EM EM EM GM EM GM GM GM GM GM EM GM GM GM GM TF GM GM GM GM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM EM GM GM GM GM GM EM GM GM GM EM EM GM GM GM GM GM TF EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X GOOSEBERRY LANE BLUE YONDER WAY YEARLING ROAD CUTTING HORSE DRIVE BUCKING HORSE - FILING ONE GREAT WESTERN RAILROAD BUCKING HORSE - FILING TWO BUCKING HORSE - FILING THREE PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED SUBDRAIN OS1 4.96 OS2 4.44 2 3.18 3a 3.56 5 5.82 1 1.22 OS4 0.64 OS3 2.33 4 1.43 4 1 5 3a 2 OS1 OS2 OS4 OS3 PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN EXISTING STORM DRAIN NANCY GRAY AVENUE MILES HOUSE AVENUE 3b 3.08 3b 1 1 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NOTES: 1. REFER TO THE FINAL DRAINAGE REPORT FOR BUCKING HORSE APARTMENTS, DATED MAY 11, 2016 FOR ADDITIONAL INFORMATION. 2. TRACT A IS BEYOND THE LIMITS OF THESE PLANS. NO IMPROVEMENTS ARE PROPOSED OUTSIDE THE LIMITS SHOWN. BENCHMARK FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION Project Datum: NGVD 29 Unadjusted (Old City of Fort Collins Datum) City of Fort Collins Benchmark 4-07 Southwest corner of Timberline Rd. and Bear Mountain Dr. due north of new police building on the southwest corner of a catch basin. Elevation = 4939.66 City of Fort Collins Benchmark 17-92 300 feet south of the southwest corner of East Drake Rd. and Timberline Rd. in the top of an irrigation structure. Elevation = 4935.51 Note: If NAVD 88 Datum is required for any purpose, the following equations should be used: NAVD 88 = NGVD 29 Unadjusted + 3.18' (FOR BM 4-07) NAVD 88 = NGVD 29 Unadjusted + 3.19' (FOR BM17-92) Basis of Bearings The Northeast line of Tract M, Bucking Horse Filing One as bearing South 49° 38' 07" East (assumed bearing). NORTH ( IN FEET ) 0 1 INCH = 80 FEET 80 80 160 240 LEGEND: 4953 PROPOSED CONTOUR 93 PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED PROPERTY BOUNDARY CURB & GUTTER PROPOSED INLET A DESIGN POINT FLOW ARROW DRAINAGE BASIN LABEL BASIN DESIGNATION BASIN AREA (AC) DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 1 1 B2 1.45 ac DR1 DRAINAGE EXHIBIT A. Reese L. Seeber 1"=80' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Drng\687-004_DRNG.dwg LAYOUT NAME: DR1 DATE: May 10, 2016 - 3:28pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xUTIL] [687-004_xEXST] [687-004_xSITE] [687-004_xADJ] [NES-xborder] [687-004_xGRAD] [687-004_xTOPO] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four X X X X X X X X X X X X X X X X X X X X UD UD UD UD \A1;38.6' 23.2% 12.2% 21.2% 7.3% POOL 14.4% 7.4% 24.3% 22.8% PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN MILES HOUSE AVENUE MILES HOUSE AVENUE (PRIVATE DRIVE) BUCKING HORSE- FILING THREE BUCKING HORSE- FILING TWO CALABRESE STREET (PRIVATE DRIVE) EXISTING 18" RCP (2) - EXISTING 18" RCP EXISTING 24" RCP N:16814.86 E:12564.55 NANCY GRAY AVENUE EXISTING 30" RCP N:16899.16 E:12481.75 EXISTING 18" RCP 5.7% 0.8% 0.8% 8.1% 4.6% 0.8% 0.8% 1.3% 1.2% 1.5% 1.5% 3.8% 1.5% 5.8% 4.2% 1.5% 92.04 91.53 91.51 91.73 93.47 93.15 93.02 93.40 94.12 94.09 94.14 94.44 93.17 93.22 94.14 94.55 95.39 95.28 94.55 94.44 94.41 94.25 94.04 93.99 95.87 96.15 96.46 95.66 95.36 95.22 95.26 95.56 95.07 95.00 94.99 95.48 96.82 95.73 96.82 95.93 95.92 93.20 93.05 93.15 93.52 91.40 90.94 90.92 96.30 96.34 95.25 93.05 92.39 (92.37) (94.26) CLUBHOUSE FFE=92.04 91.90 92.11 94.55 93.24 96.20 96.27 94.85 94.97 94.99 94.02 94.05 93.85 92.90 93.14 94.06 94.05 BLDG 19 FFE=97.23 BLDG 18 FFE=95.49 BLDG 17 FFE=94.56 BLDG 16 FFE=93.64 95.86 93.89 92.07 93.82 94.06 93.62 93.95 94.14 92.45 92.62 92.03 95.59 (92.13) (92.47) (91.86) (92.24) 91.96 91.43 91.64 (92.68) (93.13) BLDG 14 FFE=97.24 BLDG 15 FFE=96.14 BLDG 15 FFE=94.64 (93.46) (93.08) 93.31 93.80 96.15 96.11 93.14 95.31 94.26 95.19 92.04 92.00 91.95 90.51 90.50 94.32 92.40 95.53 94.37 90.43 91.90 92.04 2.0% 4.3% 5.0% 4.3% 5.0% 4.7% 5.0% 5.0% 93.98 95.07 93.97 94.38 93.77 93.67 93.66 93.96 93.98 93.98 93.99 93.77 93.96 95.06 95.19 95.59 95.49 95.59 95.48 95.59 95.48 95.49 94.80 96.71 96.38 96.58 96.58 96.58 96.50 92.04 91.37 91.37 91.37 91.37 92.04 93.64 93.64 93.64 93.64 93.64 93.64 93.64 93.64 93.64 93.64 93.64 93.64 93.64 94.56 94.56 94.56 94.56 94.56 94.56 94.56 94.56 94.56 94.56 94.56 94.56 95.49 95.49 95.49 95.49 95.49 95.49 95.49 95.49 95.49 95.49 95.49 97.23 97.23 97.23 97.26 97.26 97.26 97.23 97.23 97.23 97.23 97.23 97.23 PROPOSED 12" HDPE PROPOSED 12" HDPE 92.00 92.83 95.35 97.25 96.84 PROPOSED 18" FES EXISTING WETLANDS CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 G4 GRADING PLAN A. Reese L. Seeber 1" = 30' MATCHLINE - SEE SHEET G3 MATCHLINE - SEE SHEET G1 MATCHLINE - SEE SHEET G2 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Grad\687-004_GRAD.dwg LAYOUT NAME: G4 DATE: May 10, 2016 - 3:27pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xUTIL] [687-004_xEXST] [687-004_xGRAD] [687-004_xSITE] [687-004_xTOPO] [NES-xborder] [687-004_KEYMAP] [687-004_xADJ] [687-004_3D_Proposed] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four KEYMAP G1 G2 G4 G3 LEGEND: 5013 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED OUTFLOW CURB AND GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NGVD 29 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. TRACT A IS BEYOND THE LIMITS OF THESE PLANS. NO IMPROVEMENTS ARE PROPOSED OUTSIDE THE LIMITS SHOWN. NOTES: PROPOSED STORM INLET PEDESTRIAN ACCESS RAMPS EXISTING SPOT ELEVATION (47.45) PROPOSED FIRE HYDRANT PROPOSED ELECTRIC TRANSFORMER PROPOSED LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING RIGHT OF WAY PROPOSED INFLOW CURB AND GUTTER X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X C T CO CO W W 20.1% 21.9% 32.4% 23.2% 9.8% POOL 29.7% 26.6% 11.9% 11.7% 13.8% 25.0% 36.6% PROPOSED RAIN GARDEN YEARLING ROAD BLUE YONDER WAY CALABRESE STREET (PRIVATE DRIVE) ANDALUSIAN STREET (PRIVATE DRIVE) BUCKING HORSE- FILING THREE GOOSEBERRY LANE STORM DRAIN A SEE SHEET ST1 NANCY GRAY AVENUE N:17213.72 E:11584.51 LANDSCAPE RETAINING WALLS 0.8% 1.2% 4.2% 3.7% 6.4% 1.5% 1.0% 1.5% 2.0% 1.5% 4.4% 3.7% 1.5% 3.9% 1.4% 2.5% 0.9% 1.5% 2.3% 6.0% 1.5% 1.4% 1.5% 1.4% 1.5% PROPOSED RAIN GARDEN 0.9% 2.0% 1.8% 2.0% 0.3% 1.9% 3.5% 20.8% 3-6" STEPS 5.0% 5.0% 4.3% 14.4% 4.3% 12.8% 2.0% 0.9% 1.4% 2.0% 95.87 96.15 96.46 96.82 95.93 95.92 96.85 96.77 96.75 97.11 97.10 97.12 97.46 96.42 96.48 96.59 96.46 97.49 98.00 0.26 2.23 2.20 2.50 97.63 97.56 97.54 98.48 98.96 98.90 99.01 1.49 2.32 2.35 2.50 2.66 2.70 (2.82) 0.48 0.39 98.42 98.36 98.39 98.81 96.09 95.63 95.63 95.93 97.38 97.02 97.17 97.37 97.20 97.30 96.82 96.71 96.73 96.75 95.27 95.34 95.83 96.83 97.24 96.30 96.34 98.46 2.28 2.26 97.23 96.15 96.47 95.80 95.67 96.87 96.91 96.90 97.08 97.27 97.40 97.63 98.96 98.00 98.60 98.86 98.32 98.21 2.37 2.24 0.91 (3.12) 2.77 2.38 2.15 0.64 1.00 98.96 97.30 96.83 96.71 96.28 95.79 95.69 96.55 96.85 96.47 97.32 96.76 96.71 96.46 95.67 (3.23) (3.38) (3.31) (2.76) (1.80) (1.24) (0.09) (99.86) (99.44) 94.75 91.90 96.41 96.56 95.93 95.42 94.55 93.24 98.05 0.97 0.36 98.37 97.71 96.79 96.38 98.59 98.69 97.66 96.36 99.52 96.99 93.85 BLDG 23 FFE=2.74 BLDG 22 FFE=99.38 BLDG 21 FFE=98.04 BLDG 20 FFE=97.26 BLDG 19 FFE=97.23 96.69 0.56 95.59 FFE=97.81 (2.92) (4.16) (2.90) (4.70) (5.25) (4.90) (3.74) (3.85) (3.19) (3.20) (3.65) (2.15) (2.41) (2.05) (3.03) BLDG 12 FFE=99.07 BLDG 12 BLDG 11 FFE=0.07 FFE=2.20 BLDG 11 FFE=0.70 BLDG 13 FFE=97.56 BLDG 13 FFE=98.06 BLDG 14 FFE=98.74 BLDG 14 FFE=97.24 BLDG 15 FFE=96.14 97.07 95.87 95.54 96.61 96.85 2.34 97.16 96.39 96.15 96.11 93.14 97.47 95.65 97.67 3.18 2.81 95.31 96.01 95.63 96.44 0.94 0.61 (2.71) 96.90 98.67 95.56 97.90 98.37 99.26 98.84 96.13 97.58 96.86 96.46 97.20 97.03 96.77 98.27 0.59 0.72 99.17 98.75 98.14 0.03 1.69 97.10 97.18 92.04 92.00 91.95 94.32 96.62 99.25 96.70 96.48 96.50 96.47 95.53 96.09 96.45 97.18 96.69 96.30 96.08 96.05 96.43 95.58 91.90 92.04 0.96 99.51 99.21 98.21 99.93 99.16 98.88 4.7% 5.0% 4.0% 5.3% 0.4% 2.0% 4.0% 2.1% 2.0% 1.2% 2.0% 2.0% 5.0% 4.4% 3.5% 3.0% 5.0% 5.0% 93.77 93.96 95.06 95.19 95.59 95.49 95.59 95.48 95.59 98.08 98.08 98.08 98.08 97.78 97.55 97.34 97.22 97.48 98.08 97.29 96.71 96.46 96.38 96.58 96.58 96.58 96.50 96.98 97.08 98.08 97.78 97.79 97.74 98.90 98.70 98.81 98.69 98.76 99.40 99.70 99.81 99.40 99.52 99.40 99.40 99.40 99.40 99.40 99.51 99.25 99.46 98.46 98.75 98.90 99.01 98.93 98.90 98.90 98.90 98.90 1.53 1.53 1.15 1.07 0.77 1.07 0.55 0.24 99.84 0.03 0.03 0.14 0.14 0.03 0.03 0.03 0.48 1.53 1.53 1.77 1.75 1.53 0.96 1.26 0.32 98.81 98.81 99.19 97.37 97.39 97.39 97.39 97.50 97.39 97.41 97.10 97.39 96.60 96.91 96.69 96.69 97.17 96.99 96.95 97.41 97.18 97.30 97.39 97.39 99.47 97.26 97.26 97.26 97.23 97.23 97.23 97.23 97.23 97.26 97.26 97.26 97.26 97.26 97.26 98.04 98.04 98.04 98.04 98.04 98.04 98.04 98.04 99.38 99.37 99.37 99.37 99.37 99.37 99.39 99.38 99.36 2.74 2.74 2.74 2.74 2.74 2.74 2.74 2.74 FFE=96.75 FFE=96.50 PROPOSED 12" HDPE 95.35 95.95 3-6" STEPS 3-6" STEPS 97.14 97.62 0.72 97.25 96.84 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 G3 GRADING PLAN A. Reese L. Seeber 1" = 30' MATCHLINE - SEE SHEET G1 MATCHLINE - SEE SHEET G4 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Grad\687-004_GRAD.dwg LAYOUT NAME: G3 DATE: May 10, 2016 - 3:27pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xUTIL] [687-004_xEXST] [687-004_xGRAD] [687-004_xSITE] [687-004_xTOPO] [NES-xborder] [687-004_KEYMAP] [687-004_xADJ] [687-004_3D_Proposed] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four KEYMAP G1 G2 G4 G3 LEGEND: 5013 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED OUTFLOW CURB AND GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NGVD 29 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. TRACT A IS BEYOND THE LIMITS OF THESE PLANS. NO IMPROVEMENTS ARE PROPOSED OUTSIDE THE LIMITS SHOWN. NOTES: PROPOSED STORM INLET PEDESTRIAN ACCESS RAMPS EXISTING SPOT ELEVATION (47.45) PROPOSED FIRE HYDRANT PROPOSED ELECTRIC TRANSFORMER PROPOSED LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING RIGHT OF WAY PROPOSED INFLOW CURB AND GUTTER X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X \A1;38.6' X X X X X X X X X X X X X X X X X X X X X 7.3% 6.2% POOL PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN MILES HOUSE AVENUE NANCY GRAY AVENUE LUSITANO LANE (PRIVATE DRIVE) MILES HOUSE AVENUE (PRIVATE DRIVE) BUCKING HORSE- FILING TWO GREAT WESTERN RAILROAD TRACT A CALABRESE STREET (PRIVATE DRIVE) STORM DRAIN C SEE SHEET ST2 STORM DRAIN D SEE SHEET ST2 N:17203.96 E:12871.22 N:16814.86 E:12564.55 EXISTING 2' CONCRETE PAN EXISTING 15" RCP EXISTING 30" RCP EXISTING 15" RCP EXISTING 30" RCP N:16899.16 E:12481.75 1.0% 1.0% 1.0% 1.0% 12.9% 2.0% 1.5% 1.5% 1.5% 1.5% 3.1% 2.4% 2.9% 1.6% 9.4% 1.5% 1.5% 1.8% 1.2% 1.7% 8.2% 7.8% 1.2% 5.1% 1.5% 5.7% 0.8% 1.5% 1.5% 3.8% 7.5% 4.8% 13.2% 2.9% 5.8% 4.2% 1.5% 1.5% 1.4% 1.5% 3.8% 1.4% 3.1% 1.5% 1.3% 1.5% 1.4% 1.5% 2.0% 5.2% 7.8% 1.7% 2.9% 3-6" STEPS 3-6" STEPS 91.45 89.82 90.47 90.99 91.50 91.51 91.53 91.37 92.04 91.53 91.51 91.73 93.47 92.83 92.72 92.80 92.93 92.48 92.72 92.49 92.72 92.90 92.34 92.08 92.28 92.47 91.82 91.63 91.53 91.67 91.92 91.22 91.06 91.16 91.45 90.63 90.01 90.45 90.45 92.25 92.26 92.21 90.82 90.78 90.80 90.56 91.65 91.36 91.24 91.42 92.17 91.95 91.65 91.85 91.40 90.94 90.92 90.70 90.08 89.90 89.49 89.14 89.30 89.36 89.83 89.84 90.55 90.60 90.59 91.01 90.91 90.27 90.21 91.45 91.35 90.71 90.65 90.67 91.35 91.20 91.14 92.02 91.46 91.80 91.08 92.10 93.05 92.39 91.35 92.69 92.49 92.02 91.05 91.11 90.41 90.31 91.91 91.29 91.21 90.79 90.72 90.30 90.22 89.80 89.75 89.46 89.62 89.62 90.56 91.43 90.23 90.42 90.57 90.67 90.66 91.26 91.17 91.30 91.49 91.59 91.54 91.24 91.13 90.63 90.82 91.25 90.87 91.03 (92.53) (92.46) (92.68) (92.89) (91.50) (92.37) BLDG 5 FFE=91.45 CLUBHOUSE FFE=92.04 90.91 91.90 91.91 92.41 91.35 91.18 91.61 91.48 91.32 91.33 91.43 91.73 91.99 91.69 91.63 91.89 92.02 92.11 91.36 91.31 90.54 90.45 90.64 90.47 90.29 91.01 90.12 89.95 89.97 90.90 89.71 89.67 89.45 89.47 93.24 91.44 91.87 92.90 92.02 92.02 92.02 92.04 92.04 92.07 92.62 92.03 92.03 FFE=89.73 FFE=89.62 FFE=91.21 FFE=90.72 FFE=90.22 FFE=91.71 89.91 (91.64) (91.95) (92.00) (92.42) (92.00) (92.25) (92.87) (92.00) (92.37) (92.64) (92.31) (92.55) (92.17) (92.44) (91.50) (91.41) (92.19) (92.13) (92.13) (92.56) (92.47) (91.86) (92.24) 91.96 91.43 91.64 91.27 91.38 91.52 91.86 91.69 (92.68) (93.13) (93.90) 90.79 BLDG 8 FFE=94.09 BLDG 3 FFE=93.81 BLDG 3 FFE=93.81 BLDG 4 FFE=92.79 BLDG 4 FFE=92.79 BLDG 10 FFE=93.16 BLDG 10 FFE=93.16 BLDG 15 FFE=94.64 (93.46) (93.45) (93.08) (93.08) 91.43 91.46 90.94 90.68 90.56 90.22 93.14 91.61 91.54 91.92 92.22 92.17 91.45 91.37 92.00 91.94 93.15 92.54 91.45 91.46 91.01 89.81 91.12 91.00 90.88 91.06 91.09 91.37 91.64 91.32 91.54 91.82 89.08 (86.80) (86.07) 90.21 90.29 90.81 90.11 90.87 90.84 91.42 91.13 90.91 91.29 92.08 92.21 91.28 91.35 91.69 92.00 91.76 92.17 91.66 92.52 93.30 92.86 92.41 92.02 92.53 92.53 93.43 93.30 92.81 92.82 94.17 91.79 92.20 92.69 92.11 92.19 92.77 92.00 92.04 92.04 92.00 91.95 90.51 90.50 90.53 91.06 90.62 91.92 92.40 91.34 90.93 90.20 91.91 94.28 92.08 90.23 90.57 91.10 90.57 90.92 92.00 91.99 92.12 (85.51) (86.39) 91.90 92.04 4.7% 2.0% 4.7% 5.0% 2.0% 0.6% 2.0% 5.2% 4.6% 2.0% 2.0% 0.5% 2.0% 3.4% 4.2% 4.0% 14.1% 4.2% 0.1% 2.0% 4.8% 27.8% 2.7% 2.0% 5.0% 5.0% 93.98 92.16 90.77 90.06 94.49 94.60 93.12 93.81 93.14 93.25 93.14 92.98 93.81 93.12 93.81 93.13 93.81 92.89 92.12 92.12 92.18 92.27 92.23 92.13 91.92 92.07 92.18 91.92 92.12 92.23 92.49 92.48 92.49 92.47 92.45 92.51 91.91 91.71 91.67 92.49 92.52 92.53 92.53 92.53 92.53 92.52 92.69 92.49 92.48 92.49 92.49 92.47 92.60 92.49 93.77 93.67 93.66 93.96 93.98 93.98 93.99 93.96 93.77 93.42 93.41 93.42 93.35 93.42 93.42 93.42 93.42 93.42 92.04 91.37 91.37 91.37 91.37 92.04 92.04 92.04 91.10 91.88 92.04 92.04 93.64 93.64 93.64 93.64 93.64 93.64 91.45 91.45 91.45 91.45 91.45 91.45 91.45 91.45 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 G2 GRADING PLAN A. Reese L. Seeber 1" = 30' MATCHLINE - SEE SHEET G1 MATCHLINE - SEE SHEET G4 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Grad\687-004_GRAD.dwg LAYOUT NAME: G2 DATE: May 10, 2016 - 3:27pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xUTIL] [687-004_xEXST] [687-004_xGRAD] [687-004_xSITE] [687-004_xTOPO] [NES-xborder] [687-004_KEYMAP] [687-004_xADJ] [687-004_3D_Proposed] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four KEYMAP G1 G2 G4 G3 LEGEND: 5013 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED OUTFLOW CURB AND GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NGVD 29 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. TRACT A IS BEYOND THE LIMITS OF THESE PLANS. NO IMPROVEMENTS ARE PROPOSED OUTSIDE THE LIMITS SHOWN. NOTES: PROPOSED STORM INLET PEDESTRIAN ACCESS RAMPS EXISTING SPOT ELEVATION (47.45) PROPOSED FIRE HYDRANT PROPOSED ELECTRIC TRANSFORMER PROPOSED LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING RIGHT OF WAY PROPOSED INFLOW CURB AND GUTTER X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 9.8% 9.2% 2.1% POOL PROPOSED RAIN GARDEN GOOSEBERRY LANE BLUE YONDER WAY CUTTING HORSE DRIVE ANDALUSIAN STREET (PRIVATE DRIVE) LUSITANO LANE (PRIVATE DRIVE) BUCKING HORSE- FILING ONE GREAT WESTERN RAILROAD TRACT A EXISTING 2' CONCRETE PAN N:17734.95 E:11994.09 N:17811.14 E:12058.85 STORM DRAIN A SEE SHEET ST1 STORM DRAIN B SEE SHEET ST2 STORM DRAIN A SEE SHEET ST1 4.2% 3.7% 6.0% 1.5% 1.4% 1.5% 1.5% 1.5% 2.0% 5.2% 7.8% 1.7% 2.9% 1.5% 1.5% 1.5% 1.6% 1.6% 1.5% 2.1% 11.1% 16.5% 5.2% 1.5% 1.5% 1.5% 1.5% 2.0% 1.5% 1.6% 1.8% 2.0% 0.3% 1.9% 0.6% 2.0% 0.4% 2.0% 2.0% 5.6% 5.0% 2.0% 3.5% 20.8% 3-6" STEPS (95.56) 95.54 95.67 95.69 95.57 95.14 94.10 93.60 93.36 93.39 93.69 92.28 97.37 96.78 94.98 94.56 94.47 94.07 93.61 95.11 96.18 96.01 95.73 (95.60) 94.71 94.63 94.72 94.98 94.14 94.04 94.03 94.09 94.40 93.72 93.54 93.60 93.91 93.23 93.13 93.11 93.18 93.50 92.83 92.72 92.80 92.93 92.48 92.72 94.77 94.78 94.52 93.93 93.66 93.60 93.38 92.49 92.72 92.90 92.25 92.26 92.21 91.65 91.36 91.24 91.42 92.17 91.95 91.65 91.85 94.15 94.20 96.82 96.71 96.73 96.75 91.35 91.20 91.14 92.02 91.46 92.69 92.01 91.95 93.01 92.91 92.27 92.21 92.40 93.39 93.49 92.80 92.69 92.75 93.84 93.94 93.20 95.27 95.34 95.83 93.33 97.23 92.69 91.91 91.29 91.21 96.47 95.80 95.67 96.06 96.47 97.32 96.76 96.71 96.46 95.67 (92.57) (98.02) (98.87) (0.09) (99.86) (99.44) (92.71) 92.79 91.39 90.80 91.52 91.91 92.03 92.31 90.91 96.43 95.35 94.75 93.11 91.90 91.91 92.41 (96.59) 94.45 95.69 95.91 97.41 96.19 95.76 97.81 98.30 91.89 92.59 94.55 95.16 94.66 91.89 92.02 95.93 93.24 (96.08) (96.10) FFE=92.70 FFE=92.20 FFE=91.71 FFE=93.69 FFE=93.19 92.77 92.70 92.20 91.78 91.71 (96.20) (95.87) (96.55) (96.84) (97.00) (96.66) (96.89) (96.24) (97.28) (96.92) (96.39) (96.72) BLDG 1 FFE=95.99 BLDG 1 FFE=95.99 BLDG 1 FFE=95.66 BLDG 2 FFE=95.16 BLDG 7 FFE=97.63 BLDG 7 FFE=97.63 BLDG 8 FFE=95.86 BLDG 8 FFE=94.09 BLDG 6 FFE=99.48 BLDG 6 FFE=98.48 BLDG 3 FFE=93.81 BLDG 11 FFE=0.70 BLDG 13 FFE=97.56 97.07 93.14 95.08 95.18 95.33 95.42 92.85 91.61 91.54 91.92 94.01 93.96 93.00 94.36 94.69 93.95 93.69 93.60 93.66 93.66 93.69 93.19 93.27 93.31 93.14 93.83 93.44 93.50 92.70 92.21 92.22 92.17 94.03 92.65 92.71 93.10 93.04 92.30 91.91 91.45 91.37 92.00 91.94 93.15 93.55 94.45 94.52 94.64 93.88 95.56 92.54 93.62 (89.41) (90.10) 93.69 93.07 92.82 92.77 94.17 93.02 94.41 93.40 94.10 93.40 94.74 93.99 95.28 93.91 94.40 94.22 94.58 94.02 94.46 94.00 94.87 95.49 95.23 95.24 93.60 94.11 94.98 93.92 94.39 93.20 91.68 91.68 91.68 94.78 95.38 93.26 93.11 95.61 93.19 98.07 97.90 98.31 97.09 95.83 95.91 96.52 97.25 96.43 96.09 96.68 96.75 93.82 98.75 98.14 0.03 93.41 93.21 92.00 92.04 92.04 92.00 91.95 94.70 98.10 98.10 98.98 98.98 91.68 91.92 99.25 97.61 96.76 95.54 96.18 94.33 94.56 92.91 91.34 92.12 96.70 97.26 96.05 95.58 91.90 92.04 (88.75) (89.22) 99.51 99.21 98.21 99.93 2.0% 0.8% 2.9% 2.0% 5.0% 4.5% 5.8% 5.0% 96.16 96.58 5.2% 4.0% 4.6% 4.0% 4.0% 3.2% 2.0% 2.0% 4.3% 5.0% 3.6% 2.0% 3.6% 4.0% 4.0% 4.3% 3.5% 3.0% 5.0% 5.0% 1.2% 2.0% 0.8% 2.0% 3.5% 4.1% 92.16 95.33 95.33 95.30 95.31 95.33 95.52 95.23 95.33 95.28 95.33 94.49 94.99 94.55 94.64 94.49 94.60 95.00 94.79 94.42 95.05 94.49 94.64 94.99 95.10 92.98 92.89 93.96 93.77 0.24 99.84 0.03 0.03 0.14 0.14 0.03 0.03 0.03 0.48 0.32 98.81 98.81 98.98 99.03 98.51 98.81 98.43 98.26 98.10 97.81 97.80 97.80 97.81 97.81 97.81 97.81 97.81 98.26 99.19 98.97 99.03 98.81 98.39 98.70 98.09 96.97 96.97 97.37 97.25 97.02 96.97 97.26 97.37 96.97 97.08 96.97 96.97 96.97 96.97 96.97 96.98 96.68 97.02 97.02 96.70 96.97 96.98 97.08 96.97 96.97 96.97 96.97 95.33 95.33 95.09 95.33 95.33 95.24 95.46 95.33 95.33 95.33 95.33 95.33 95.33 95.20 95.20 95.17 94.61 95.20 93.62 93.41 93.42 93.41 93.42 95.20 95.20 95.41 95.20 94.31 93.21 93.32 93.35 93.42 93.42 93.42 93.42 93.42 97.41 97.10 97.39 96.60 96.91 96.69 96.89 96.89 96.89 96.89 96.89 97.00 96.69 97.17 96.99 96.95 97.41 97.18 97.30 95.49 93.60 94.40 94.18 95.36 94.59 94.74 99.47 FFE=96.75 FFE=96.50 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 G1 GRADING PLAN A. Reese L. Seeber 1" = 30' MATCHLINE - SEE SHEET G3 MATCHLINE - SEE SHEET G2 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Grad\687-004_GRAD.dwg LAYOUT NAME: G1 DATE: May 10, 2016 - 3:27pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xUTIL] [687-004_xEXST] [687-004_xGRAD] [687-004_xSITE] [687-004_xTOPO] [NES-xborder] [687-004_KEYMAP] [687-004_xADJ] [687-004_3D_Proposed] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four KEYMAP G1 G2 G4 G3 LEGEND: 5013 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED OUTFLOW CURB AND GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NGVD 29 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. TRACT A IS BEYOND THE LIMITS OF THESE PLANS. NO IMPROVEMENTS ARE PROPOSED OUTSIDE THE LIMITS SHOWN. NOTES: PROPOSED STORM INLET PEDESTRIAN ACCESS RAMPS EXISTING SPOT ELEVATION (47.45) PROPOSED FIRE HYDRANT PROPOSED ELECTRIC TRANSFORMER PROPOSED LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING RIGHT OF WAY PROPOSED INFLOW CURB AND GUTTER X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X BUCKING HORSE- FILING ONE BUCKING HORSE- FILING THREE BUCKING HORSE- FILING THREE BUCKING HORSE- FILING TWO BUCKING HORSE- FILING TWO GREAT WESTERN RAILROAD TRACT A BLDG 23 BLDG 22 BLDG 21 BLDG 20 BLDG 19 BLDG 18 BLDG 17 BLDG 16 BLDG 13 BLDG 14 BLDG 15 BLDG 12 BLDG 11 BLDG 7 BLDG 8 BLDG 6 BLDG 1 BLDG 2 BLDG 3 BLDG 4 BLDG 5 CLUBHOUSE BLDG 10 MILES HOUSE AVENUE GOOSEBERRY LANE YEARLING ROAD BLUE YONDER WAY NANCY GRAY AVENUE CUTTING HORSE DRIVE CALABRESE STREET (PRIVATE DRIVE) ANDALUSIAN STREET (PRIVATE DRIVE) LUSITANO LANE (PRIVATE DRIVE) LUSITANO LANE (PRIVATE DRIVE) CALABRESE STREET (PRIVATE DRIVE) MILES HOUSE AVENUE (PRIVATE DRIVE) PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN STORM DRAIN D SEE SHEET ST2 STORM DRAIN C SEE SHEET ST2 STORM DRAIN B SEE SHEET ST2 STORM DRAIN A SEE SHEET ST1 STORM DRAIN A SEE SHEET ST1 PROPOSED RAIN GARDEN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 OG1 OVERALL GRADING PLAN A. Reese L. Seeber 1" = 50' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Grad\687-004_OAGRAD.dwg LAYOUT NAME: OG1 DATE: May 10, 2016 - 3:26pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xUTIL] [687-004_xEXST] [687-004_xGRAD] [687-004_xSITE] [687-004_xTOPO] [687-004_xADJ] [NES-xborder] [687-004_KEYMAP] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four KEYMAP G1 G2 G4 G3 LEGEND: 5013 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB AND GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES PROPOSED STORM INLET PEDESTRIAN ACCESS RAMPS EXISTING SPOT ELEVATION (47.45) PROPOSED FIRE HYDRANT PROPOSED ELECTRIC TRANSFORMER PROPOSED LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING RIGHT OF WAY PROPOSED RIGHT OF WAY FOR REFERENCE ONLY. SEE 30 SCALE DRAWINGS FOR DETAILED INFORMATION. 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NGVD 29 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. TRACT A IS BEYOND THE LIMITS OF THESE PLANS. NO IMPROVEMENTS ARE PROPOSED OUTSIDE THE LIMITS SHOWN. NOTES: FES D STA 10+00.00 N: 17204.22 E: 12812.63 68.76 LF 15" RCP @ 0.40% 206.64 LF 15" RCP @ 0.40% EXISTING 2' CONCRETE PAN INSTALL 2' CONCRETE PAN LID VAULT 4885 4890 4895 4900 4905 4910 4885 4890 4895 4900 4905 4910 12+00 11+00 10+00 9+50 70.47 LF 24" RCP @ 0.50% 107.33 LF 24" RCP @ 0.50% INLET B1 STA 10+70.47 RIM 4893.1± INV. IN 4889.77 (SW) INV. OUT 4889.77 (NE) INLET B2 STA 11+77.79 RIM 4893.3± INV. OUT 4890.30 (NE) FES B STA 10+00.00 RIM 4891.8± INV. IN 4889.41 (SW) PROPOSED GRADE EXISTING GRADE STA.=11+52.36 INV.= 4885.32 12" PVC SANITARY 4880 4885 4890 4895 4900 4905 4880 4885 4890 4895 4900 4905 13+00 12+00 11+00 10+00 9+50 68.76 LF 15" RCP @ 0.40% 206.64 LF 15" RCP @ 0.40% INLET D2 STA 12+75.41 RIM 4889.8± INV. OUT 4887.17 (NE) STMH D1 STA 10+68.76 RIM 4889.1± INV. IN 4886.34 (SW) INV. OUT 4886.34 (NE) FES D STA 10+00.00 RIM 4887.9± INV. IN 4886.07 (SW) PROPOSED GRADE EXISTING GRADE STA.=11+35.76 INV.= 4884.25 STA.=11+51.51 8" PVC WATER INV.= 4882.85 12" PVC SANITARY SS SS SS SS S X X CO TF TF TF EM GM EM EM EM GM GM TF FDC FDC W S W S F F CALABRESE STREET (PRIVATE DRIVE) STMH C2 STA 12+57.20 N: 17143.12 E: 12487.38 INLET C3 STA 13+59.20 N: 17067.27 E: 12419.18 FES C STA 10+00.00 N: 17339.09 E: 12653.96 68.76 LF 15" RCP @ 0.35% 102.00 LF 15" RCP @ 0.35% BLDG 4 BLDG 3 188.44 LF 15" RCP @ 0.35% INLET C1 STA 10+68.76 N: 17286.69 E: 12609.43 LID VAULT LID VAULT EXISTING 2' CONCRETE PAN INSTALL 2' CONCRETE PAN LUSITANO LANE (PRIVATE DRIVE) 4880 4885 4890 4895 4900 4905 4880 4885 4890 4895 4900 4905 14+00 13+00 12+00 11+00 10+00 9+50 68.76 LF 15" RCP @ 0.35% 102.00 LF 15" RCP @ 0.35% STMH C2 STA 12+57.20 RIM 4892.1± INV. IN 4887.71 (SW) INV. OUT 4887.71 (NE) INLET C3 STA 13+59.20 RIM 4890.6± INV. OUT 4888.06 (NE) FES C STA 10+00.00 RIM 4888.6± INV. IN 4886.80 (SW) PROPOSED GRADE EXISTING GRADE 188.44 LF 15" RCP @ 0.35% INLET C1 STA 10+68.76 RIM 4890.1± INV. IN 4887.04 (SW) INV. OUT 4887.04 (NE) STA.=11+50.76 INV.= 4883.29 12" PVC SANITARY STA.=11+35.76 INV.= 4884.92 8" PVC WATER STA.=12+86.58 INV.= 4885.45 8" PVC WATER No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Strm\687-004_STRM B C D.dwg LAYOUT NAME: ST2 DATE: May 10, 2016 - 3:25pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xUTIL] [687-004_xADJ] [687-004_xEXST] [687-004_xSITE] [687-004_xTOPO] [NES-xborder] [687-004_KEYMAP] [687-004_xSTRM_leg] [687-004_xGRAD] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four KEYMAP EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D PROPOSED LOT LINE EXISTING EASEMENT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY EXISTING STORM SEWER PROPOSED EASEMENT LINE 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. PROPOSED RIGHT OF WAY PROPOSED AREA DRAINS CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 STORM DRAIN C PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' STORM DRAIN B STORM DRAIN D NORTH ST2 PLAN & PROFILE STORM DRAIN B, C & D A. Reese L. Seeber 1"=50' STORM DRAIN B STORM DRAIN C STORM DRAIN D PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' INLET SCHEDULE INLET ID INLET TYPE A2 Triple Combination A3 Double Combination A6 Triple Combination B2 Single Area Inlet C3 Double Combination D3 Double Combination RIPRAP SCHEDULE Storm Line/Culvert Label Riprap Type Length of Riprap (ft) Width of Riprap (ft) 2*d50, Depth of Riprap (ft) Storm A Type M 12.00 10.00 1.5 Storm B Type M 10.00 8.00 1.5 Storm C Type M 5.00 5.00 1.5 Storm D Type M 5.00 5.00 1.5 S S S S S 140.46 LF 30" RCP @ 0.50% 25.02 LF 24" RCP @ 0.50% 87.90 LF 18" RCP @ 0.50% 383.24 LF 18" RCP @ 0.50% 53.96 LF 18" RCP @ 0.50% S S I R FDC F F FDC W W W S BLDG 6 BLDG 11 EXISTING 2' CONCRETE PAN STMH A4 STA 16+36.62 N: 17327.00 E: 11688.68 INLET A5 STA 16+90.58 N: 17291.75 E: 11647.82 STMH A3 STA 12+53.38 N: 17619.00 E: 11936.88 INLET A2 STA 11+65.48 N: 17679.19 E: 12000.95 INLET A1 STA 11+40.46 N: 17698.14 E: 12017.28 FES A STA 10+00.00 N: 17805.58 E: 12107.76 GOOSEBERRY LANE BLUE YONDER WAY YEARLING ROAD CUTTING HORSE DRIVE LUSITANO LANE (PRIVATE DRIVE) CALABRESE STREET (PRIVATE DRIVE) INSTALL 2' CONCRETE PAN 96.01 4880 4885 4890 4895 4900 4905 4910 4915 4880 4885 4890 4895 4900 4905 4910 4915 17+50 17+00 16+00 15+00 14+00 13+00 12+00 11+00 10+00 9+50 140.46 LF 30" RCP @ 0.50% 25.02 LF 24" RCP @ 0.50% 87.90 LF 18" RCP @ 0.50% 383.24 LF 18" RCP @ 0.50% 53.96 LF 18" RCP @ 0.50% STMH A4 STA 16+36.62 RIM 4902.8± INV. IN 4893.28 (SW) INV. OUT 4893.28 (NE) INLET A5 STA 16+90.58 RIM 4903.1± INV. OUT 4893.55 (NE) STMH A3 STA 12+53.38 RIM 4897.4± INV. IN 4891.37 (SW) INV. OUT 4891.37 (NE) INLET A2 STA 11+65.48 RIM 4895.9± INV. IN 4890.93 (SW) INV. INLET OUT A1 4890.93 (NE) STA 11+40.46 RIM 4895.5± INV. IN 4890.80 (SW) INV. OUT 4890.80 (NE) FES A STA 10+00.00 RIM 4893.0± INV. IN 4890.10 (SW) PROPOSED GROUND EXISTING GROUND STA.=13+17.00 INV.= 4893.76 2" WATER SERVICE STA.=15+04.05 INV.= 4894.95 2" WATER SERVICE STA.=14+97.05 INV.= 4894.95 6" FIRE SERVICE STA.=13+10.00 INV.= 4893.76 6" FIRE SERVICE STA.=11+49.65 INV.= 4888.43 8" PVC WATER STA.=16+64.07 INV.= 4898.22 8" PVC WATER No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Strm\687-004_STRM A.dwg LAYOUT NAME: ST1 DATE: May 10, 2016 - 3:22pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xUTIL] [687-004_xADJ] [687-004_xEXST] [687-004_xGRAD] [687-004_xSITE] [687-004_xTOPO] [NES-xborder] [687-004_KEYMAP] [687-004_xSTRM_leg] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four ST1 PLAN & PROFILE STORM DRAIN A A. Reese L. Seeber 1"=50' NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 KEYMAP STORM DRAIN A EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D PROPOSED LOT LINE EXISTING EASEMENT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY EXISTING STORM SEWER PROPOSED EASEMENT LINE 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. PROPOSED RIGHT OF WAY PROPOSED AREA DRAINS CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner STORM DRAIN A INLET SCHEDULE INLET ID INLET TYPE A2 Triple Combination A3 Double Combination A6 Triple Combination B2 Single Area Inlet C3 Double Combination D3 Double Combination PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' RIPRAP SCHEDULE Storm Line/Culvert Label Riprap Type Length of Riprap (ft) Width of Riprap (ft) 2*d50, Depth of Riprap (ft) Storm A Type M 12.00 10.00 1.5 Storm B Type M 10.00 8.00 1.5 Storm C Type M 5.00 5.00 1.5 Storm D Type M 5.00 5.00 1.5 E: 12142.74 SSMH B STA 10+00.00 N: 17359.84 E: 12396.37 SSMH B1 STA 11+38.18 N: 17254.55 E: 12306.88 215.42 LF 8" PVC @ 0.50% 113.46 LF 8" PVC @ 0.50% 138.18 LF 8" PVC @ 0.50% LUSITANO LANE ANDALUSIAN STREET SANITARY LINE B2 SEE THIS SHEET CONNECT TO EXISTING 12" PVC SANITARY EXISTING 12" PVC SANITARY VAN TF TF TF TF TF EM GM EM EM EM EM GM GM EM GM GM GM S S S S S S S W W W FDC FDC FDC FDC FDC F F F F F W W SSMH B2-1 STA 13+20.81 N: 17149.63 E: 11934.96 320.81 LF 8" PVC @ 0.50% SSMH B2 STA 10+00.00 N: 17394.07 E: 12142.74 ANDALUSIAN STREET SANITARY LINE B SEE THIS SHEET 4880 4885 4890 4895 4900 4905 4910 4880 4885 4890 4895 4900 4905 4910 15+00 14+00 13+00 12+00 11+00 10+00 9+50 SSMH B2 STA 13+53.60 RIM 4894.5± INV. IN 4886.17 (SW) INV. IN 4886.17 (NW) INV. OUT 4885.97 (SE) 113.46 LF 8" PVC @ 0.50% 215.42 LF 8" PVC @ 0.50% 138.18 LF 8" PVC @ 0.50% SSMH B3 STA 14+67.06 RIM 4893.9± INV. OUT 4886.74 (SE) SSMH B STA 10+00.00 RIM 4892.7± INV. IN 4884.00 (SW) INV. IN 4884.00 (NW) INV. OUT 4883.80 (SE) SSMH B1 STA 11+38.18 RIM 4891.9± INV. IN 4884.89 (NW) INV. OUT 4884.69 (NE) PROPOSED GROUND EXISTING GROUND STA.=11+98.70 INV.= 4887.73 2" WATER SERVICE STA.=14+27.84 INV.= 4889.30 2" WATER SERVICE STA.=13+63.60 INV.= 4889.42 8" PVC WATER STA.=14+34.84 INV.= 4889.30 6" FIRE SERVICE STA.=11+91.70 INV.= 4887.73 6" FIRE SERVICE 2.5' 4880 4885 4890 4895 4900 4905 4910 4880 4885 4890 4895 4900 4905 4910 13+50 13+00 12+00 11+00 10+00 9+50 SSMH B2-1 STA 13+20.81 RIM 4896.4± INV. OUT 4887.77 (NE) SSMH B2 STA 10+00.00 RIM 4894.5± INV. IN 4886.17 (SW) INV. IN 4886.17 (NW) INV. OUT 4885.97 (SE) 320.81 LF 8" PVC @ 0.50% PROPOSED GROUND EXISTING GROUND STA.=11+73.74 INV.= 4890.87 2" WATER SERVICE STA.=11+63.98 INV.= 4890.87 6" FIRE SERVICE TF TF EM EM GM EM GM EM GM EM GM X X X X X X X S S S W FDC W F W W S S SSMH A2 STA 10+00.00 N: 16967.43 E: 12344.55 103.06 LF 8" PVC @ 0.50% SSMH A2-1 STA 11+03.06 N: 16926.05 E: 12250.16 4875 4880 4885 4890 4895 4900 4905 4910 4875 4880 4885 4890 4895 4900 4905 4910 11+25 11+00 10+00 9+50 103.06 LF 8" PVC @ 0.50% SSMH A2-1 STA 11+03.06 RIM 4892.9± INV. OUT 4886.58 (NE) SSMH A2 STA 10+00.00 RIM 4891.8± INV. IN 4886.07 (SE) INV. IN 4886.07 (SW) INV. OUT 4885.87 (NE) PROPOSED GROUND EXISTING GROUND STA.=10+13.03 INV.= 4887.39 8" PVC WATER 0.6' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Util\687-004_ SAN A2 B B3.dwg LAYOUT NAME: SS2 DATE: May 10, 2016 - 3:20pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xUTIL] [687-004_xADJ] [687-004_xEXST] [687-004_xSITE] [NES-xborder] [687-004_KEYMAP] [687-004_xSAN_leg] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four KEYMAP EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 3. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. ALL FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 6. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS, SERVICES AND AREA DRAINS. 7. ALL MULTI-FAMILY SANITARY SEWER SERVICES TO BE 6" PVC. ALL TOWNHOME SANITARY SEWER SERVICES TO BE 4" PVC. 8. ALL SANITARY MANHOLES TO BE 4' Ø 9. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. EXISTING STORM SEWER PROPOSED SEWER SERVICE S EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H YD LOT LINE EASEMENT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY PROPOSED CURB STOP & WATER METER W EXISTING RIGHT-OF-WAY PROPOSED CURB STOP & IRRIGATION METER IR 8" SS 8" W NORTH NORTH SANITARY SEWER LINE B SANITARY SEWER LINE B3 SANITARY SEWER LINE B SANITARY SEWER LINE B2 SS2 PLAN & PROFILE SANITARY SEWER LINE A2, B & B3 A. Reese L. Seeber 1"=50' ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' NORTH SANITARY SEWER LINE A2 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X W W W W W S S S S S S S S W W W W W W W W S W W W W W W W W SS SS SS SS SS CO CO CO CO S S W W S S S S S S S S S S S S S S W WV V WV WV GAS WV H Y D h 2o GAS WV WV C T WV H Y D CO CO SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS S S S S S S S S S S SANITARY LINE B3 SEE SHEET SS2 BLDG 23 BLDG 22 BLDG 21 BLDG 20 BLDG 19 BLDG 18 BLDG 17 BLDG 16 BLDG 13 BLDG 14 BLDG 15 BLDG 12 BLDG 11 CLUBHOUSE S S S S S S S S S S S S S IR W W W W W FDC FDC FDC FDC FDC S W FDC FDC W F F F F F F S F W W W W W W W W S S S W W S W S W S W S W S W S W SSMH A10 STA 20+06.52 N: 17147.44 E: 11741.52 SSMH A6 STA 15+33.45 N: 16860.37 E: 12101.20 SSMH A5 STA 14+22.89 N: 16859.01 E: 12211.76 SSMH A4 STA 13+12.32 N: 16889.21 E: 12318.11 SSMH A3 STA 12+51.42 N: 16922.16 E: 12369.33 SSMH A2 STA 11+99.81 N: 16967.43 E: 12344.55 SSMH A1 STA 11+36.87 N: 17009.11 E: 12391.71 PIPE END A STA 10+00.00 N: 16920.47 E: 12496.00 SSMH A7 STA 16+44.01 N: 16893.17 E: 11995.62 SSMH A8 STA 17+54.57 N: 16954.69 E: 11903.75 SSMH A9 STA 19+03.38 N: 17069.29 E: 11808.83 136.87 LF 8" PVC @ 0.50% 62.94 LF 8" PVC @ 0.50% 51.61 LF 8" PVC @ 0.50% 60.90 LF 8" PVC @ 0.50% 110.56 LF 8" PVC @ 0.50% 110.56 LF 8" PVC @ 0.50% 110.56 LF 8" PVC @ 0.50% 110.56 LF 8" PVC @ 0.50% 148.80 LF 8" PVC @ 0.50% 103.14 LF 8" PVC @ 1.00% CALABRESE STREET (PRIVATE DRIVE) ANDALUSIAN STREET (PRIVATE DRIVE) MILES HOUSE AVENUE (PRIVATE DRIVE) 8" PVC WATER 8" PVC WATER 103.22 LF 8" PVC @ 1.00% SSMH A11 STA 21+09.74 N: 17217.56 E: 11665.78 SANITARY LINE B3 SEE SHEET SS2 4880 4885 4890 4895 4900 4905 4910 4915 4880 4885 4890 4895 4900 4905 4910 4915 21+50 21+00 20+00 19+00 18+00 17+00 16+00 15+00 14+00 13+00 12+00 11+00 10+00 9+50 136.87 LF 8" PVC @ 0.50% 62.94 LF 8" PVC @ 0.50% 51.61 LF 8" PVC @ 0.50% 60.90 LF 8" PVC @ 0.50% 110.56 LF 8" PVC @ 0.50% 110.56 LF 8" PVC @ 0.50% 110.56 LF 8" PVC @ 0.50% 110.56 LF 8" PVC @ 0.50% 148.80 LF 8" PVC @ 0.50% 103.14 LF 8" PVC @ 1.00% SSMH A10 STA 20+06.52 RIM 4899.5± INV. IN 4892.22 (NW) INV. OUT 4892.02 (SE) SSMH A9 STA 19+03.38 RIM 4897.6± INV. IN 4890.99 (NW) INV. OUT 4890.79 (SE) SSMH A8 STA 17+54.57 RIM 4896.6± INV. IN 4890.04 (NW) INV. OUT 4889.84 (SE) SSMH A7 STA 16+44.01 RIM 4895.9± INV. IN 4889.29 (NW) INV. OUT 4889.09 (E) SSMH A6 STA 15+33.45 RIM 4895.0± INV. IN 4888.54 (W) INV. OUT 4888.34 (E) SSMH A5 STA 14+22.89 RIM 4894.1± INV. IN 4887.78 (W) INV. OUT 4887.58 (E) SSMH A4 STA 13+12.32 RIM 4893.2± INV. IN 4887.03 (W) INV. OUT 4886.83 (NE) SSMH A3 STA 12+51.42 RIM 4892.6± INV. IN 4886.53 (SW) INV. OUT 4886.33 (NW) SSMH A2 STA 11+99.81 RIM 4891.8± INV. IN 4886.07 (SE) INV. IN 4886.07 (SW) INV. OUT 4885.87 (NE) SSMH A1 STA 11+36.87 RIM 4891.3± INV. IN 4885.55 (SW) INV. OUT 4885.35 (SE) PIPE END A STA 10+00.00 RIM 4885.4± INV. IN 4884.67 (NW) PROPOSED GROUND EXISTING GROUND 103.22 LF 8" PVC @ 1.00% SSMH A11 STA 21+09.74 RIM 4902.3± INV. OUT 4893.25 (SE) STA.=10+55.88 INV.= 4887.13 3/4" WATER SERVICE STA.=12+86.23 INV.= 4888.10 3/4" WATER SERVICE STA.=13+48.71 INV.= 4888.58 3/4" WATER SERVICE STA.=13+99.01 INV.= 4889.03 3/4" WATER SERVICE STA.=14+62.80 INV.= 4889.51 3/4" WATER SERVICE STA.=15+13.04 INV.= 4889.97 3/4" WATER SERVICE STA.=15+76.89 INV.= 4890.44 3/4" WATER SERVICE STA.=16+26.96 INV.= 4890.92 3/4" WATER SERVICE STA.=16+90.81 INV.= 4891.34 3/4" WATER SERVICE STA.=17+40.90 INV.= 4891.77 3/4" WATER SERVICE STA.=18+05.12 INV.= 4892.11 3/4" WATER SERVICE STA.=18+56.81 INV.= 4892.47 3/4" WATER SERVICE STA.=19+24.97 INV.= 4892.95 3/4" WATER SERVICE STA.=19+77.35 INV.= 4893.94 3/4" WATER SERVICE STA.=20+47.21 INV.= 4895.91 3/4" WATER SERVICE STA.=20+99.73 INV.= 4897.31 3/4" WATER SERVICE No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Util\687-004_SAN A.dwg LAYOUT NAME: SS1 DATE: May 10, 2016 - 3:19pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xUTIL] [687-004_xADJ] [687-004_xEXST] [687-004_xSITE] [NES-xborder] [687-004_KEYMAP] [687-004_xSAN_leg] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four SANITARY SEWER LINE A PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' KEYMAP SS1 PLAN & PROFILE SANITARY SEWER LINE A A. Reese L. Seeber 1"=50' SANITARY SEWER LINE A NORTH EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 3. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. ALL FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 6. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS, SERVICES AND AREA DRAINS. 7. ALL MULTI-FAMILY SANITARY SEWER SERVICES TO BE 6" PVC. ALL TOWNHOME SANITARY SEWER SERVICES TO BE 4" PVC. 8. ALL SANITARY MANHOLES TO BE 4' Ø 9. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. EXISTING STORM SEWER PROPOSED SEWER SERVICE S EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H YD LOT LINE EASEMENT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY PROPOSED CURB STOP & WATER METER W EXISTING RIGHT-OF-WAY PROPOSED CURB STOP & IRRIGATION METER IR 8" SS 8" W ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner CO CO CO S S S S S S S S S S S S S S S S S S TF TF TF EM GM GM GM EM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS S S S S S S S S S CONNECT TO EXISTING 8" SANITARY STUB INV = ±4884.7 N:16920.47 E:12496.00 N:16899.16 E:12481.75 N:16815.10 E:12565.12 S S S S S S IR W S FDC FDC W F W W W W S S S W W S W S EXISTING SSMH RIM=4892.62 INV. IN=4884.67 INV. OUT=4884.64 8"x6" SWIVEL TEE & 1-6" GV (NW) & FH ASSEMBLY N:16918.75 E:12345.17 8"x6" TEE w/TB & 6" GV (SE) N:16944.65 E:12261.99 BUCKING HORSE- FILING THREE BUCKING HORSE- FILING TWO BLDG 19 BLDG 18 BLDG 17 BLDG 16 BLDG 15 CLUBHOUSE SANITARY LINE A SEE SHEET SS1 SANITARY LINE A SEE SHEET SS1 EXISTING 18" RCP (2) - EXISTING 18" RCP EXISTING 24" RCP EXISTING 18" RCP EXISTING 30" RCP SSMH A7 SSMH A6 SSMH A5 SSMH A4 SSMH A3 SSMH A2 SSMH A1 18.81 LF 8" PVC S44°32'26"W 17.02 LF 8" PVC S56°29'00"W 47.32 LF 8" PVC S32°57'45"E 10.55 LF 8" PVC S13°28'24"W 5.47 LF 8" PVC S58°28'24"W 1.91 LF 8" PVC S58°28'24"W 2 6 5 . 2 4 L F 8 " P V C R = 3 70 . 0 0 ' 49.90 LF 8" PVC S67°44'00"W 15.70 LF 8" PVC R=300.00' 4 7 . 4 1 L F 8 " PV C R = 30 0 . 0 0 ' 16.89 LF 8" PVC S37°56'52"W 46.52 LF 8" PVC S07°56'16"E 45.00° BEND w/ TB N:16921.61 E:12349.83 45.00° BEND w/ TB N:16931.87 E:12352.29 END HORZ. DEFL. 45.00° BEND w/ TB N:16932.60 E:12216.19 45.00° BEND w/ TB N:16919.28 E:12205.81 11.25° BEND w/ TB N:16969.12 E:12322.85 BEGIN HORZ. DEFLECTION N:16917.75 E:12343.54 END HORZ. DEFLECTION N:16980.97 E:12340.73 N49°38'05"W 8"x8" TEE w/TB & 2-8" GV (SE,SW) N:16971.57 E:12326.54 SSMH A2-1 BEGIN HORZ. DEFLECTION N:16950.21 E:12276.67 8"x8" TEE w/ TB & 2-8" GV (NW,NE) N:16873.21 E:12212.23 MILES HOUSE AVENUE MILES HOUSE AVENUE (PRIVATE DRIVE) CALABRESE STREET (PRIVATE DRIVE) PROPOSED 18" FES 3/4" WATER METER 3/4" WATER METER 3/4" WATER METER 3/4" WATER METER 3/4" WATER METER 3/4" WATER METER 3/4" WATER METER 3/4" WATER METER 4.43 LF 8" PVC S56°29'00"W NANCY GRAY AVENUE 2" WATER METER EXISTING WETLANDS EXISTING 12" SANITARY SEWER EXISTING 8" WATER MAIN EXISTING 8" PVC SANITARY SEWER EXISTING 8" PVC SANITARY SEWER U4 UTILITY PLAN A. Reese L. Seeber 1"=30' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 MATCHLINE - SEE SHEET U2 MATCHLINE - SEE SHEET U3 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Util\687-004_UTIL.dwg LAYOUT NAME: U4 DATE: May 10, 2016 - 3:18pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xUTIL] [687-004_xSITE] [687-004_xEXST] [NES-xborder] [687-004_KEYMAP] [687-004_xADJ] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four WET UTILITY SERVICE TABLE TAP & METER SIZE SUPPLY LINE SIZE FIRE SANITARY SEWER 32-UNIT BUILDINGS 2" 2" 6" 6" 28-UNIT BUILDINGS 2" 2" 6" 6" TOWNHOME 3/4" - - 4" CLUBHOUSE 1" 1.25" 6" 4" POOL - - - TBD IRRIGATION 1.5" - - - KEYMAP U1 U2 U4 U3 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 3. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 5. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 6. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 7. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAINE CLEANOUTS PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 8. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 9. THE MINIMUM COVER OVER WATER LINES IS 4.5 FEET AND THE MAXIMUM COVER IS 5.5 FEET UNLESS OTHERWISE NOTED IN THE PLANS AND APPROVED BY THE WATER UTILITY. 10. TRACT A EXTENDS BEYOND THE LIMITS OF THESE PLANS. NO IMPROVEMENTS ARE PROPOSED OUTSIDE THE LIMITS SHOWN. W G T EXISTING STORM SEWER ST EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING TELEPHONE PEDESTAL F PROPOSED FIRE SERVICE EXISTING SANITARY SEWER SS PROPOSED STORM INLET EXISTING LIGHT POLE PROPOSED FIRE DEPT. CONN. PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER FDC PROPOSED LIGHT POLE PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D PROPOSED LOTLINE EASEMENT LINE CONWTROL IRR W S O E G PROPERTY BOUNDARY S W PROPOSED SEWER SERVICE PROPOSED CURB STOP & METER PIT IR PROPOSED IRRIGATION CURB STOP & METER PIT PROPOSED ELECTRIC TRANSFORMER PROPOSED AREA DRAIN TF S S S SS SS SS S S VAN TF TF TF TF TF TF EM EM GM GM EM GM GM TF EM EM EM EM EM GM GM GM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X WV WV WV WV GAS WV H Y D h 2o GAS S C T CO CO SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS S S S S S S CONNECT TO EXISTING STUB 11.25° BEND w/ TB N:17297.79 E:11681.15 N:17213.72 E:11584.51 S S S S S S S S W W W W FDC FDC FDC FDC F F F F W W W W W S W S W S W S W S 8"x6" SWIVEL TEE & 1-6" GV (NE) & FH ASSEMBLY N:16929.83 E:11958.89 8"x6" SWIVEL TEE & 1-6" GV (N) & FH ASSEMBLY N:17127.55 E:11902.64 8"x6" SADDLE TAP w/ TB & 1-6" GV (SE) N:17446.75 E:11763.07 EXISTING SSMH RIM = 4904.17 INV. IN = 4893.44 (NW) INV. OUT = 4893.24 (NE) BUCKING HORSE- FILING THREE BLDG 23 BLDG 22 BLDG 21 BLDG 20 BLDG 19 BLDG 13 BLDG 14 BLDG 12 BLDG 11 STORM DRAIN A SEE SHEET ST1 SANITARY LINE A SEE SHEET SS1 SANITARY LINE B2 SEE SHEET SS2 EXISTING 8" PVC SANITARY SEWER SSMH A10 SSMH A9 SSMH A8 SSMH A7 SSMH B2-1 8"X6" TEE w/ 6" GV (NE) N:17156.01 E:11821.27 8"X6" TEE w/ 6" GV (SE) N:17144.68 E:11917.63 8"X6" TEE w/ 6" GV (SE) N:17275.63 E:12028.95 2 6 5 . 1 11. 2 6 L F 8 " P V C R = 3 7 0 . 0 0 ' 138.99 LF 8" PVC N39°38'05"W 1 4 7 . 64 L F 8 " P V C R = 849.00 ' 8.00 LF 8" PVC N49°35'54"W 3.90 LF 8" PVC N04°35'54"W 52.25 LF 8" PVC N40°21'55"E 26.79 LF 8" PVC S37°14'44"E 18.43 LF 8" PVC S49°38'05"E 10.03 LF 8" PVC S49°38'05"E 1 44 . 5 8 L F 8 " P V C R = 90 5 .0 0 ' 13.37 LF 8" PVC R=905.00' 49.15 LF 8" PVC S39°38'05"E 20.00 LF 8" PVC S86°38'05"E 27.92 LF 8" PVC R=300.00' 13.97 LF 8" PVC R=300.00' 8.80 LF 8" PVC N40°21'55"E 171.87 LF 8" PVC N40°21'59"E 173.94 LF 8" PVC N40°21'50"E BEGIN HORZ. DEFL. 45.00° BEND w/ TB N:17106.75 E:11881.20 45.00° BEND w/ TB N:17107.92 45.00° BEND w/ TB E:11861.23 N:17224.71 E:11677.56 45.00° BEND w/ TB N:17220.83 E:11677.87 11.25° BEND w/ TB N:17276.47 E:11697.36 END HORZ. DEFLECTION N:17137.97 E:11911.93 END HORZ. DEFLECTION N:17145.77 E:11829.88 END HORZ. DEFLECTION N:17258.03 E:11719.05 END HORZ. DEFLECTION N:17215.64 E:11683.96 BEGIN HORZ. DEFLECTION N:17110.68 E:11787.53 END HORZ. DEFLECTION N:17003.64 E:11876.19 YEARLING ROAD BLUE YONDER WAY CALABRESE STREET (PRIVATE DRIVE) CALABRESE STREET (PRIVATE DRIVE) GOOSEBERRY LANE ANDALUSIAN STREET (PRIVATE DRIVE) ASPHALT PATCH 6" SANITARY SERVICE N:17408.94 E:11718.07 INV.= 2" WATER METER 3/4" WATER METER 3/4" WATER METER 3/4" WATER METER 3/4" WATER METER 3/4" WATER METER 3/4" WATER METER 3/4" WATER METER 3/4" WATER METER 3/4" WATER METER LANDSCAPE RETAINING WALLS 2" WATER METER 2" WATER METER 2" WATER METER 8"x8" TEE w/TB & 2-8" GV (SE,SW) N:17264.53 E:11711.40 SSMH A11 EXISTING 8" PVC SANITARY SEWER U3 UTILITY PLAN A. Reese L. Seeber 1"=30' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 MATCHLINE - SEE SHEET U1 MATCHLINE - SEE SHEET U4 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Util\687-004_UTIL.dwg LAYOUT NAME: U3 DATE: May 10, 2016 - 3:17pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xUTIL] [687-004_xSITE] [687-004_xEXST] [NES-xborder] [687-004_KEYMAP] [687-004_xADJ] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four WET UTILITY SERVICE TABLE TAP & METER SIZE SUPPLY LINE SIZE FIRE SANITARY SEWER 32-UNIT BUILDINGS 2" 2" 6" 6" 28-UNIT BUILDINGS 2" 2" 6" 6" TOWNHOME 3/4" - - 4" CLUBHOUSE 1" 1.25" 6" 4" POOL - - - TBD IRRIGATION 1.5" - - - KEYMAP U1 U2 U4 U3 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 3. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 5. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 6. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 7. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAINE CLEANOUTS PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 8. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 9. THE MINIMUM COVER OVER WATER LINES IS 4.5 FEET AND THE MAXIMUM COVER IS 5.5 FEET UNLESS OTHERWISE NOTED IN THE PLANS AND APPROVED BY THE WATER UTILITY. 10. TRACT A EXTENDS BEYOND THE LIMITS OF THESE PLANS. NO IMPROVEMENTS ARE PROPOSED OUTSIDE THE LIMITS SHOWN. W G T EXISTING STORM SEWER ST EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING TELEPHONE PEDESTAL F PROPOSED FIRE SERVICE EXISTING SANITARY SEWER SS PROPOSED STORM INLET EXISTING LIGHT POLE PROPOSED FIRE DEPT. CONN. PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER FDC PROPOSED LIGHT POLE PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D PROPOSED LOTLINE EASEMENT LINE CONWTROL IRR W S O E G PROPERTY BOUNDARY S W PROPOSED SEWER SERVICE PROPOSED CURB STOP & METER PIT IR PROPOSED IRRIGATION CURB STOP & METER PIT PROPOSED ELECTRIC TRANSFORMER PROPOSED AREA DRAIN TF GM TF EM GM EM GM EM GM X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X WV WV WV WV WV H Y D H Y D GAS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS S S S S S S S CONNECT TO EXISTING STUB N:16932.89 E:12500.06 CONNECT TO EXISTING 8" SANITARY STUB INV = ±4884.7 N:16920.47 E:12496.00 FH ASSEMBLY w/6" GV (SW) N:17424.17 E:12470.08 8"x8" TEE w/ 8"X6" REDUCER (NE) N:17364.98 E:12413.87 8"X12" SADDLE TAP w/ TB & 1-8" GV (NW) N:17045.42 E:12789.82 N:17203.86 E:12871.15 N:16899.16 E:12481.75 N:16815.10 E:12565.12 IR S W FDC FDC FDC S W FDC S W W S F F S F F S W W EXISTING SSMH RIM=4892.62 INV. IN=4884.67 INV. OUT=4884.64 8"x6" SWIVEL TEE & 1-6" GV (NE) & FH ASSEMBLY N:17186.66 E:12402.19 BEGIN HORZ. DEFL. 8"x8" TEE w/TB & 2-8" GV (SE,SW) N:17024.73 E:12392.00 EXISTING SSMH RIM = 4892.33 INV. IN = 4883.47 (NW) INV. OUT = 4883.27 (SE) EXISTING SSMH RIM = 4892.74 INV. IN = 4882.60 (NW) INV. OUT = 4882.40 (SW) BUCKING HORSE- FILING TWO BLDG 3 BLDG 4 BLDG 5 CLUBHOUSE BLDG 10 GREAT WESTERN RAILROAD TRACT A SANITARY LINE B SEE SHEET SS2 STORM DRAIN D SEE SHEET ST2 EXISTING 12" SANITARY EXISTING 8" SANITARY SANITARY LINE A SEE SHEET SS1 EXISTING 15" RCP EXISTING 30" RCP EXISTING 42" RCP EXISTING 30" RCP 8"x6" TEE w/ TB & 1-6" GV (NW) N:17030.10 E:12397.28 SSMH A3 SSMH B SSMH B1 SSMH A2 SSMH A1 8"X6" TEE w/ 6" GV (SW) N:17269.37 E:12526.36 8"X6" TEE w/ 6" GV (SW) N:17160.58 E:12654.35 63.36 LF 8" PVC S49°38'05"E 106.60 LF 8" PVC S49°38'05"E 85.46 LF 8" PVC S49°38'05"E 28.82 LF 8" PVC S02°27'34"E 101.60 LF 8" PVC S44°32'26"W 18.81 LF 8" PVC S44°32'26"W 17.02 LF 8" PVC S56°29'00"W 47.32 LF 8" PVC S32°57'45"E 10.55 LF 8" PVC S13°28'24"W 5.47 LF 8" PVC S58°28'24"W 147.63 LF 8" PVC S49°38'05"E 104.23 LF 8" PVC S49°38'05"E 241.55 LF 8" PVC S49°38'05"E 143.44 LF 8" PVC N40°21'55"E 31.78 LF 6" PVC N40°21'55"E 34.40 LF 6" PVC R=250.00' 15.58 LF 6" PVC N48°14'57"E 45.00° BEND w/ TB N:16931.87 E:12352.29 11.25° BEND w/ TB N:16969.12 E:12322.85 45.00° BEND w/ TB N:17102.51 E:12468.54 8"X8" TEE w/ 2-8" GV (NE,SE) N:17255.69 E:12320.97 BEGIN HORZ. DEFLECTION N:17389.20 E:12434.45 END HORZ. DEFLECTION N:17413.79 E:12458.46 END HORZ. DEFLECTION N:16980.97 E:12340.73 127.05 LF 8" PVC N49°38'05"W 15.00 LF 8" PVC N49°38'05"W 8"x8" TEE w/TB & 2-8" GV (SE,SW) N:16971.57 E:12326.54 MILES HOUSE AVENUE NANCY GRAY AVENUE LUSITANO LANE (PRIVATE DRIVE) MILES HOUSE AVENUE (PRIVATE DRIVE) CALABRESE STREET (PRIVATE DRIVE) 45.00° BEND w/ TB N:17131.31 E:12467.31 8"X6" TEE w/ 6" GV (SW) N:16962.91 E:12464.74 STORM DRAIN C SEE SHEET ST2 LID VAULTS LID VAULTS LID VAULTS LID VAULTS 2" WATER METER 2" WATER METER 3/4" WATER METER AREA INLET AREA INLET AREA INLET AREA INLET 3/4" WATER METER 2" WATER METER 1" WATER METER 4.43 LF 8" PVC S56°29'00"W COMBO INLET COMBO INLET EXISTING 2' CONCRETE PAN EXISTING 8" WATER MAIN U2 UTILITY PLAN A. Reese L. Seeber 1"=30' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 MATCHLINE - SEE SHEET U4 MATCHLINE - SEE SHEET U1 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Util\687-004_UTIL.dwg LAYOUT NAME: U2 DATE: May 10, 2016 - 3:17pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xUTIL] [687-004_xSITE] [687-004_xEXST] [NES-xborder] [687-004_KEYMAP] [687-004_xADJ] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four WET UTILITY SERVICE TABLE TAP & METER SIZE SUPPLY LINE SIZE FIRE SANITARY SEWER 32-UNIT BUILDINGS 2" 2" 6" 6" 28-UNIT BUILDINGS 2" 2" 6" 6" TOWNHOME 3/4" - - 4" CLUBHOUSE 1" 1.25" 6" 4" POOL - - - TBD IRRIGATION 1.5" - - - KEYMAP U1 U2 U4 U3 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 3. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 5. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 6. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 7. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAINE CLEANOUTS PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 8. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 9. THE MINIMUM COVER OVER WATER LINES IS 4.5 FEET AND THE MAXIMUM COVER IS 5.5 FEET UNLESS OTHERWISE NOTED IN THE PLANS AND APPROVED BY THE WATER UTILITY. 10. TRACT A EXTENDS BEYOND THE LIMITS OF THESE PLANS. NO IMPROVEMENTS ARE PROPOSED OUTSIDE THE LIMITS SHOWN. W G T EXISTING STORM SEWER ST EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING TELEPHONE PEDESTAL F PROPOSED FIRE SERVICE EXISTING SANITARY SEWER SS PROPOSED STORM INLET EXISTING LIGHT POLE PROPOSED FIRE DEPT. CONN. PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER FDC PROPOSED LIGHT POLE PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D PROPOSED LOTLINE EASEMENT LINE CONWTROL IRR W S O E G PROPERTY BOUNDARY S W PROPOSED SEWER SERVICE PROPOSED CURB STOP & METER PIT IR PROPOSED IRRIGATION CURB STOP & METER PIT PROPOSED ELECTRIC TRANSFORMER PROPOSED AREA DRAIN TF 1.5" IRRIGATION METER GM GM GM GM X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X FO VAULT F.O. WV WV WV GAS h2o WV WV SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS S SS SS SS SS S S S S FH ASSEMBLY w/6" GV (SW) N:17424.17 E:12470.08 8"x8" TEE w/ 8"X6" REDUCER (NE) N:17364.98 E:12413.87 N:17859.27 E:12099.77 N:17734.94 E:11994.08 N:17718.42 E:12013.51 S S S S S S IR W W FDC FDC FDC FDC FDC FDC F F F F F F F W W W FDC W W 8"x6" SWIVEL TEE & 1-6" GV (NE) & FH ASSEMBLY N:17670.02 E:12022.19 8"x6" SWIVEL TEE & 1-6" GV (NE) & FH ASSEMBLY N:17422.04 E:12125.27 8"x6" SADDLE TAP w/ TB & 1-6" GV (SE) N:17589.72 E:11884.29 8"x6" SADDLE TAP w/ TB & 1-6" GV (SE) N:17446.75 E:11763.07 EXISTING SSMH RIM = 4896.68 INV. IN = 4886.06(NW) INV. IN = 4886.06 (SW) INV. OUT = 4885.90 (SE) EXISTING SSMH RIM = 4894.52 INV. IN = 4885.65 (NW) INV. OUT = 4885.45 (SE) EXISTING SSMH RIM = 4894.02 INV. IN = 4884.86 (NW) INV. OUT = 4884.66 (SE) EXISTING SSMH RIM = 4894.53 INV. IN = 4884.30 (NW) INV. OUT = 4884.10 (SE) BUCKING HORSE- FILING ONE GREAT WESTERN RAILROAD TRACT A BLDG 13 BLDG 7 BLDG 8 BLDG 6 BLDG 1 BLDG 2 EXISTING 8" WATER EXISTING 8" SANITARY EXISTING 12" PVC SANITARY SEWER STORM DRAIN B SEE SHEET ST2 STORM DRAIN A SEE SHEET ST1 SANITARY LINE B SEE SHEET SS2 SANITARY LINE B2 SEE SHEET SS2 8"x8" TEE w/ 8" GV (SW,SE) N:17408.17 E:12141.60 SSMH B3 SSMH B2 SSMH B SSMH B1 8"X6" TEE w/ 6" GV (SE) N:17275.63 E:12028.95 8"X6" TEE w/ 6" GV (NE) N:17418.94 E:12128.92 8"X6" TEE w/ 6" GV (SW) N:17454.38 E:12087.23 8"X6" TEE w/ 6" GV (SW) N:17296.73 E:12272.70 41.51 LF 8" PVC S27°16'03"E 31.47 LF 8" PVC S27°16'03"E 10.41 LF 8" PVC S04°18'59"E 83.46 LF 8" PVC S08°32'05"W 2.67 LF 8" PVC S13°57'55"E 53.72 LF 8" PVC S49°38'05"E 49.94 LF 8" PVC S49°38'05"E 4.78 LF 8" PVC S49°38'05"E 16.64 LF 8" PVC S49°38'05"E 150.98 LF 8" PVC S49°38'05"E 21.08 LF 8" PVC S49°38'05"E 63.36 LF 8" PVC S49°38'05"E 106.60 LF 8" PVC S49°38'05"E 171.87 LF 8" PVC N40°21'59"E 173.94 LF 8" PVC N40°21'50"E 147.63 LF 8" PVC S49°38'05"E 143.44 LF 8" PVC N40°21'55"E 31.78 LF 6" PVC N40°21'55"E 34.40 LF 6" PVC R=250.00' 15.58 LF 6" PVC N48°14'57"E BEGIN HORZ. DEFLECTION N:17546.54 E:12025.65 END HORZ. DEFL. 22.50° BEND w/ TB N:17489.18 E:12046.30 22.50° BEND w/ TB N:17549.13 E:12025.00 22.50° BEND w/ TB N:17642.05 E:12036.61 CONNECT TO EXISTING WATER 22.50° BEND w/ TB N:17706.91 E:12003.17 8"X8" TEE w/ 2-8" GV (NE,SE) N:17255.69 E:12320.97 BEGIN HORZ. DEFLECTION N:17389.20 E:12434.45 END HORZ. DEFLECTION N:17413.79 E:12458.46 GOOSEBERRY LANE BLUE YONDER WAY CUTTING HORSE DRIVE ANDALUSIAN STREET (PRIVATE DRIVE) LUSITANO LANE (PRIVATE DRIVE) 8"X6" TEE w/ 6" GV (SW) N:17310.38 E:12256.64 LID VAULTS N:17811.12 E:12058.84 EXISTING 2' CONCRETE PAN 1.5" IRRIGATION METER 2" WATER METER ASPHALT PATCH 6" SANITARY SERVICE N:17551.68 E:11838.71 INV.= 2" WATER METER 2" WATER METER 2" WATER METER 2" WATER METER 2" WATER METER AREA INLET AREA INLET 2" WATER METER 11.25° BEND w/ TB N:17631.67 E:12037.39 61 . 0 7 L F 8 " P V C R = 3 0 0 . 0 0 ' U1 UTILITY PLAN A. Reese L. Seeber 1"=30' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 MATCHLINE - SEE SHEET U2 MATCHLINE - SEE SHEET U3 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Util\687-004_UTIL.dwg LAYOUT NAME: U1 DATE: May 10, 2016 - 3:17pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xUTIL] [687-004_xSITE] [687-004_xEXST] [NES-xborder] [687-004_KEYMAP] [687-004_xADJ] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four KEYMAP WET UTILITY SERVICE TABLE TAP & METER SIZE SUPPLY LINE SIZE FIRE SANITARY SEWER 32-UNIT BUILDINGS 2" 2" 6" 6" 28-UNIT BUILDINGS 2" 2" 6" 6" TOWNHOME 3/4" - - 4" CLUBHOUSE 1" 1.25" 6" 4" POOL - - - TBD IRRIGATION 1.5" - - - U1 U2 U4 U3 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 3. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 5. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 6. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 7. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAINE CLEANOUTS PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 8. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 9. THE MINIMUM COVER OVER WATER LINES IS 4.5 FEET AND THE MAXIMUM COVER IS 5.5 FEET UNLESS OTHERWISE NOTED IN THE PLANS AND APPROVED BY THE WATER UTILITY. 10. TRACT A EXTENDS BEYOND THE LIMITS OF THESE PLANS. NO IMPROVEMENTS ARE PROPOSED OUTSIDE THE LIMITS SHOWN. W G T EXISTING STORM SEWER ST EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING TELEPHONE PEDESTAL F PROPOSED FIRE SERVICE EXISTING SANITARY SEWER SS PROPOSED STORM INLET EXISTING LIGHT POLE PROPOSED FIRE DEPT. CONN. PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER FDC PROPOSED LIGHT POLE PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D PROPOSED LOTLINE EASEMENT LINE CONWTROL IRR W S O E G PROPERTY BOUNDARY S W PROPOSED SEWER SERVICE PROPOSED CURB STOP & METER PIT IR PROPOSED IRRIGATION CURB STOP & METER PIT PROPOSED ELECTRIC TRANSFORMER PROPOSED AREA DRAIN TF GM GM EM EM GM GM GM GM GM TF EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM EM GM X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X W W W W W W W W W W W W W W W W W W W W W S S S S S S S S S S W W W W W W W WWWW W WWWW W W W W W W W W W W S S W W W W W W W S W S W S W S S S S S W W W W W W W W W W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS W W X X X X X X X X X X X X X X X CO CO CO CO CO CO CO CO CO CO CO CO CO CO SS SS X X X X E E X X S S S S S S W W S S S S S S S S S S S S S S FO V AULT F.O. WV WV WV WV WV WV WV GAS h 2o GAS WV H Y D h2o GAS WV WV S C T WV WV WV WV WV H Y D H Y D GAS CO CO SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS S S S S S S S S S S S S S S S S S S S S S BUCKING HORSE- FILING ONE BUCKING HORSE- FILING THREE BUCKING HORSE- FILING THREE BUCKING HORSE- FILING TWO BUCKING HORSE- FILING TWO GREAT WESTERN RAILROAD TRACT A BLDG 23 BLDG 22 BLDG 21 BLDG 20 BLDG 19 BLDG 18 BLDG 17 BLDG 16 BLDG 13 BLDG 14 BLDG 15 BLDG 12 BLDG 11 BLDG 7 BLDG 8 BLDG 6 BLDG 1 BLDG 2 BLDG 3 BLDG 4 BLDG 5 CLUBHOUSE BLDG 10 S S S S S S S S S S S S S S S S S S IR IR S W W W W W W W FDC FDC FDC FDC FDC FDC FDC FDC FDC FDC FDC S W FDC S W W S FDC W F F F F F F F F F F F F S F F W W W W W W W W W FDC W W W S S S W W S W S W S W S W S W S W EXISTING 18" RCP STORM DRAIN D SEE SHEET ST2 STORM DRAIN C SEE SHEET ST2 STORM DRAIN B SEE SHEET ST2 STORM DRAIN A SEE SHEET ST1 STORM DRAIN A SEE SHEET ST1 PROPOSED 8" WATER CONNECT TO EXISTING 8" WATER PROPOSED 8" WATER PROPOSED 8" WATER PROPOSED 8" WATER PROPOSED 8" WATER PROPOSED 6" WATER CONNECT TO EXISTING 8" WATER CONNECT TO EXISTING 8" SANITARY SANITARY LINE B SEE SHEET SS2 SANITARY LINE B2 SEE SHEET SS2 PROPOSED 8" WATER PROPOSED FH PROPOSED FH PROPOSED FH PROPOSED FH RELOCATED FH TIE INTO EXISTING 8" WATER SANITARY LINE B SEE SHEET SS2 SANITARY LINE B2 SEE SHEET SS2 PROPOSED 8" WATER CONNECT TO EXISTING 12" PVC SANITARY EXISTING 12" PVC SANITARY PROPOSED FH PROPOSED FH PROPOSED 1.5" IRRIGATION PROPOSED 1.5" IRRIGATION SANITARY LINE A SEE SHEET SS1 SANITARY LINE A SEE SHEET SS1 SANITARY LINE A SEE SHEET SS1 EXISTING 12" SANITARY CONNECT TO EXISTING 12" WATER MAIN EXISTING FH EXISTING FH EXISTING FH CONNECT TO EXISTING 12" PVC SANITARY EXISTING 2' CONCRETE PAN EXISTING 42" RCP (2) - EXISTING 18" RCP EXISTING 30" RCP EXISTING 30" RCP EXISTING 15" RCP CONNECT TO EXISTING 8" PVC SANITARY CONNECT TO EXISTING 8" PVC WATER CONNECT TO EXISTING 8" PVC WATER MILES HOUSE AVENUE GOOSEBERRY LANE YEARLING ROAD BLUE YONDER WAY NANCY GRAY AVENUE CUTTING HORSE DRIVE CALABRESE STREET (PRIVATE DRIVE) ANDALUSIAN STREET (PRIVATE DRIVE) LUSITANO LANE (PRIVATE DRIVE) LUSITANO LANE (PRIVATE DRIVE) CALABRESE STREET (PRIVATE DRIVE) MILES HOUSE AVENUE (PRIVATE DRIVE) PROPOSED 8" WATER CONNECT TO EXISTING 12" PVC SANITARY CONNECT TO EXISTING 12" PVC SANITARY PROPOSED FES SANITARY LINE A2 SEE SHEET SS1 OU1 OVERALL UTILITY PLAN A. Reese L. Seeber 1"=50' City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 3. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 5. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 6. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 7. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAINE CLEANOUTS PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 8. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 9. THE MINIMUM COVER OVER WATER LINES IS 4.5 FEET AND THE MAXIMUM COVER IS 5.5 FEET UNLESS OTHERWISE NOTED IN THE PLANS AND APPROVED BY THE WATER UTILITY. 10. TRACT A EXTENDS BEYOND THE LIMITS OF THESE PLANS. NO IMPROVEMENTS ARE PROPOSED OUTSIDE THE LIMITS SHOWN. W G T EXISTING STORM SEWER ST EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING TELEPHONE PEDESTAL F PROPOSED FIRE SERVICE EXISTING SANITARY SEWER SS PROPOSED STORM INLET EXISTING LIGHT POLE PROPOSED FIRE DEPT. CONN. PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER FDC PROPOSED LIGHT POLE PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D PROPOSED LOTLINE EASEMENT LINE CONWTROL IRR W S O E G PROPERTY BOUNDARY S W PROPOSED SEWER SERVICE PROPOSED CURB STOP & METER PIT IR PROPOSED IRRIGATION CURB STOP & METER PIT PROPOSED ELECTRIC TRANSFORMER PROPOSED AREA DRAIN No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Util\687-004_OAUTIL.dwg LAYOUT NAME: OU1 DATE: May 10, 2016 - 3:16pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xUTIL] [687-004_xADJ] [687-004_xEXST] [687-004_xSITE] [NES-xborder] [687-004_KEYMAP] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four KEYMAP U1 U2 U4 U3 FOR REFERENCE ONLY. SEE 30 SCALE DRAWINGS FOR DETAILED INFORMATION. WET UTILITY SERVICE TABLE TAP & METER SIZE SUPPLY LINE SIZE FIRE SANITARY SEWER 32-UNIT BUILDINGS 2" 2" 6" 6" 28-UNIT BUILDINGS 2" 2" 6" 6" TOWNHOME 3/4" - - 4" CLUBHOUSE 1" 1.25" 6" 4" POOL - - - TBD IRRIGATION 1.5" - - - CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner TF X X X X X X X X X X 9' 9' 9' 9' 9' 9' 9' 9' 9' 9' 9' 8' 8' 23' 23' 8' 23' 9' 9' 9' 24' 23' 12' 13' 9' 19' 19' 19' 8' 19' 19' 19' 19' 19' 19' 19' 19' 19' BLUE YONDER WAY NANCY GRAY AVENUE CUTTING HORSE DRIVE 24' - 24'  - 24' -  4.5' SIDEWALK 9' 9' 9' 9' 9' 9' 9' 9' 9' 9' 23' 23' 23' 8' 24' 9' 19' 13' 13' 11' 12' 24' 19' 19' 20' 20' 23' 9' 19' 19' 19' 19' 19' 19' 24' -  24'  -  24' - R5' R20' POOL 9' 19' 24' - R10' R3' 9' \A1;9' CALABRESE STREET (PRIVATE DRIVE) ANDALUSIAN STREET (PRIVATE DRIVE) 8' 8' 23' 8' LUSITANO LANE (PRIVATE DRIVE) LUSITANO LANE (PRIVATE DRIVE) CALABRESE STREET (PRIVATE DRIVE) 1 2 2 MILES HOUSE AVENUE (PRIVATE DRIVE) 24' 24' 19' 9' R3' R15' 8' SIDEWALK (TYP.) 4.5' SIDEWALK RAISED CROSSWALK 4.5' SIDEWALK 8' SIDEWALK (TYP.) 4.5' SIDEWALK 1 1 10' CROSSPAN TRASH ENCLOSURE TRASH ENCLOSURE TRASH ENCLOSURE TRASH ENCLOSURE R888' BLDG 23 BLDG 22 BLDG 21 BLDG 20 BLDG 19 BLDG 18 BLDG 17 BLDG 16 BLDG 13 BLDG 14 BLDG 15 BLDG 12 BLDG 11 BLDG 7 BLDG 8 BLDG 6 BLDG 1 BLDG 2 BLDG 3 BLDG 4 BLDG 5 CLUBHOUSE BLDG 10 1 1 1 1 1 1 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK R29' 2 2 1 1 R52' R933' R20' R25' R5' R15' 18" VERTICAL CURB 4.5' SIDEWALK R332' 4.5' SIDEWALK EXISTING CONCRETE DRIVEWAY EXISTING DRIVEWAY 5.5' SIDEWALK R5' R15' R20' R5' 5.5' SIDEWALK 1 1 1 1 1 1 1 1 1 4.5' SIDEWALK 8' SIDEWALK (TYP.) 8' SIDEWALK (TYP.) TRASH ENCLOSURE 4' CROSSPAN R25' R78' R102' 1 1 4.5' SIDEWALK 8' SIDEWALK (TYP.) 8' SIDEWALK (TYP.) R20' 4.5' SIDEWALK RAISED CROSSWALK 1 5' CHASE DRAIN 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 4.5' SIDEWALK R25' R49' R25' R8' R3' 4.5' SIDEWALK 4.5' SIDEWALK R6' R3' R25' 1 R25' R20' 8' SIDEWALK (TYP.) 8' SIDEWALK (TYP.) 8' SIDEWALK (TYP.) CONCRETE DRIVEAWAY CONCRETE DRIVEAWAY CONCRETE DRIVEAWAY 8' SIDEWALK (TYP.) 8' SIDEWALK (TYP.) 8' SIDEWALK (TYP.) EXISTING 30" VERTICAL CURB & GUTTER EXISTING 30" VERTICAL CURB & GUTTER EXISTING 30" VERTICAL CURB & GUTTER LANDSCAPE RETAINING WALLS PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 4.5' CONCRETE TRAIL EXISTING 2' CONCRETE PAN 2' CURB CHASE 2' CURB CHASE 3 3 3 3 3 3 3 3 3 3 3 3 PV1 PAVING PLAN PRIVATE SIGNAGE & A. Reese L. Seeber 1"=50' LEGEND: EASEMENTS NOTES: 1. SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS. 2. PAVEMENT MARKINGS SHALL BE PER CITY STANDARDS. 3. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 4. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OR FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 5. PRIVATE CONCRETE DRIVE AISLES/PARKING STALLS SHALL BE CONSTRUCTED IN ACCORDANCE WITH ACI 330R-08. 6. ALL CURB & GUTTER SHALL BE 18" VERTICAL UNLESS OTHERWISE NOTED. 7. TRACT A EXTENDS BEYOND THE LIMITS OF THESE PLANS. NO IMPROVEMENTS ARE PROPOSED OUTSIDE THE LIMITS SHOWN. PROPOSED INFLOW VERTICAL CURB & GUTTER PROPERTY BOUNDARY PRIVATE HEAVY DUTY PAVING PROPOSED LOT LINE ASPHALT PATCH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Site\687-004_PAVE.dwg LAYOUT NAME: PV1 DATE: May 10, 2016 - 3:16pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xEXST] [NES-xborder] [687-004_xADJ] [687-004_xSITE] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four PRIVATE LIGHT DUTY PAVING SITE SIGN LEGEND 1 PRIVATE DRIVE PRIVATELY MAINTANED City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner PROPOSED OUTFLOW VERTICAL CURB & GUTTER 2 3 R7-8 RESERVED PARKING 18" 12" LANE FIRE NO PARKING R8-31D 18" 12" S S W W S W S S S S S W W W W W W W W W W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W X X X X X X X X X X X X X X X CO CO CO CO CO CO CO CO CO CO CO CO CO CO CO CO CO CO SS SS S S S S S S S S SS SS W W S S S S S S S S S S S S S S FO VAULT F.O. WV H Y D WV WV WV WV WV WV WV GAS h 2o GAS WV H Y D h2o GAS WV WV S C T WV WV WV WV WV H Y D H Y D H Y D GAS CO CO SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS S S S S S S S S S S S S S S S S S S S S S PAVEMENT REMOVAL AREA EXISTING 4.5' SIDEWALK EXISTING 51' ROW TO BE VACATED EXISTING 51' ROW TO BE VACATED EXISTING 51' ROW TO BE VACATED EXISTING 15" RCP STORM INV.=4890.51 EXISTING 4" SANITARY SERVICE (TYP.) EXISTING COMBO INLET GRATE EL.=4894.08 18" INV. OUT=4889.40 (S) EXISTING 24" FLARED END SECTION INV.=4888.94 EXISTING COMBO INLET GRATE EL.=4894.13 18" INV. IN=4889.25 (N) 24" INV. OUT=4889.18 (SE) EXISTING 8" WATER MAIN EXISTING 12" SANITARY BUCKING HORSE - FILING THREE BUCKING HORSE - FILING TWO TRACT A GREAT WESTERN RAILROAD EXISTING 3/4" WATER SERVICE (TYP.) EXISTING 8" SANITARY EXISTING 8" SANITARY EXISTING 8" SANITARY PAVEMENT SAWCUT LINE EXISTING ROLLOVER CURB & GUTTER PAVEMENT SAWCUT LINE PAVEMENT REMOVAL AREA EXISTING 8" WATER EXISTING SSMH RIM = 4904.17 INV. IN = 4893.44 (NW) INV. OUT = 4893.24 (NE) EXISTING BARRICADE TO BE REMOVED EXISTING RIPRAP TO BE REMOVED EXISTING 51' ROW TO BE VACATED EXISTING 8" PVC WATER STUB EXISTING FH PAVEMENT REMOVAL AREA EXISTING 51' ROW TO BE VACATED PAVEMENT REMOVAL AREA EXISTING RIPRAP TO BE REMOVED EXISTING BARRICADE TO BE REMOVED EXISTING 8" PVC WATER STUB EXISTING FH TO BE RELOCATED EXISTING SSMH RIM = 4896.68 INV. IN = 4886.06(NW) INV. IN = 4886.06 (SW) INV. OUT = 4885.90 (SE) EXISTING SSMH RIM = 4894.52 INV. IN = 4885.65 (NW) INV. OUT = 4885.45 (SE) EXISTING SSMH RIM = 4894.02 INV. IN = 4884.86 (NW) INV. OUT = 4884.66 (SE) EXISTING SSMH RIM = 4892.33 INV. IN = 4883.47 (NW) INV. OUT = 4883.27 (SE) EXISTING SSMH RIM = 4892.74 INV. IN = 4882.60 (NW) INV. OUT = 4882.40 (SW) EXISTING SSMH RIM = 4894.53 INV. IN = 4884.30 (NW) INV. OUT = 4884.10 (SE) EXISTING 2' CONCRETE PAN EXISTING 42" RCP FL=4885.00 EXISTING 42" RCP FL=4884.95 EXISTING 42" RCP FL=4884.79 EXISTING 42" RCP FL=4884.83 EXISTING BARRICADE EXISTING FH EXISTING 8" WATER EXISTING STREET STRIPING TO BE REMOVED PAVEMENT SAWCUT LINE EXISTING 4.5' SIDEWALK EXISTING 12" SANITARY EXISTING FH EXISTING 51' ROW TO BE VACATED EXISTING 8" SANITARY EXISTING TEMPORARY FH & REDUCER TO BE REMOVED EXISTING 8" SANITARY STUB INV=±4884.75 EXISTING BARRICADE TO BE REMOVED EXISTING SSMH RIM=4892.62 INV. IN=4884.67 INV. OUT=4884.64 PAVEMENT REMOVAL AREA EXISTING 12" PVC SANITARY SEWER PAVEMENT REMOVAL AREA PAVEMENT REMOVAL AREA PAVEMENT REMOVAL AREA NANCY GRAY AVENUE MILES HOUSE AVENUE GOOSEBERRY LANE BLUE YONDER WAY YEARLING ROAD CUTTING HORSE DRIVE SONGBIRD LANE PERENDALE LANE DRYSDALE LANE CUTTING HORSE DRIVE YEARLING DRIVE BUCKING HORSE - FILING ONE EXISTING CONCRETE DRIVEWAY TO REMAIN EXISTING WETLANDS EX1 & DEMOLITION PLAN EXISTING CONDITIONS A. Reese L. Seeber 1" = 50' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\Exist\687-004_ECON.dwg LAYOUT NAME: EX1 DATE: May 10, 2016 - 3:16pm CAD OPERATOR: luke LIST OF XREFS: [687-004_xTOPO] [687-004_xEXST] [NES-xborder] [687-004_xADJ] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four EXISTING ELECTRIC E LEGEND: G T EXISTING STORM SEWER ST EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL FIELD SURVEY BY: SUBSURFACE EXPLORATION BY: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249. 4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND CITY SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 8. TRACT A EXTENDS BEYOND THE LIMITS OF THESE PLANS. NO IMPROVEMENTS ARE PROPOSED OUTSIDE THE LIMITS SHOWN. 9. Project Datum: NGVD 29 Unadjusted (Old City of Fort Collins Datum) City of Fort Collins Benchmark 4-07 Southwest corner of Timberline Rd. and Bear Mountain Dr. due north of new police building on the southwest corner of a catch basin. Elevation = 4939.66 City of Fort Collins Benchmark 17-92 300 feet south of the southwest corner of East Drake Rd. and Timberline Rd. in the top of an irrigation structure. Elevation = 4935.51 Note: If NAVD 88 Datum is required for any purpose, the following equations should be used: NAVD 88 = NGVD 29 Unadjusted + 3.18' (FOR BM 4-07) NAVD 88 = NGVD 29 Unadjusted + 3.19' (FOR BM17-92) Basis of Bearings The Northeast line of Tract M, Bucking Horse Filing One as bearing South 49° 38' 07" East (assumed bearing). Northern Engineering Services, Inc. Project No. 687-004 Date: October 2015 EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR 5015 5013 VAULT ELEC H Y D CONTROL IRR H2O G Earth Engineering Consultants, Inc Geotechnical Exploration Report Bucking Horse Development - Southeast Project No. 1122025C Date: July 19, 2012 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by t he construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by the City of Fort Collins. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: Project Datum: NGVD 29 Unadjusted (Old City of Fort Collins Datum) City of Fort Collins Benchmark 4-07 Southwest corner of Timberline Rd. and Bear Mountain Dr. due north of new police building on the southwest corner of a catch basin. Elevation = 4939.66 City of Fort Collins Benchmark 17-92 300 feet south of the southwest corner of East Drake Rd. and Timberline Rd. in the top of an irrigation structure. Elevation = 4935.51 Note: If NAVD 88 Datum is required for any purpose, the following equations should be used: NAVD88 = NGVD29 UNADJUSTED + 3.18' (FOR BM 4-07) NAVD88 = NGVD29 UNADJUSTED + 3.19 (FOR BM 17-92) Basis of Bearings The Northeast line of Tract M, Bucking Horse Filing One as bearing South 49° 38' 07" East (assumed bearing) . 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: a. Calabrese Street b. Andalusian Street c. Lusitano Lane 48. Approved Variances are listed as follows: a. N/A CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. 16. For additional information see separate Erosion Control Report for Bucking Horse - Filing Four. B. Street Improvement Notes 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. All recommendations of the Final Drainage Report For Bucking Horse Apartments, dated May 11, 2016 by Northern Engineering shall be followed and implemented. 3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Utility Notes 1. All waterline and sanitary sewer construction shall conform to the City of Fort Collins Utility standards and specifications current to date of construction. 2. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water utility. 3. Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire. 4. HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections. Tracer wire shall be installed with the HDPE service, and shall extend up the curb stop. The curb stop shall be covered with a metal box and tracer wire test lid per City Water Detail 25. No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\687-004_COVR.dwg LAYOUT NAME: CS2 DATE: May 10, 2016 - 3:15pm CAD OPERATOR: luke LIST OF XREFS: [NES-xborder] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R CONTACT INFORMATION COVER SHEET SHEET INDEX CS1 CS2 GENERAL NOTES & CONSTRUCTION NOTES PV1 PRIVATE SIGNAGE & PAVING PLAN UTILITY PLANS FOR City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER GAS----------------- Xcel Energy----------------------------- Stephanie Rich (970) 225-7857 ELECTRIC-------- City of Fort Collins Light & Power-- Todd Vedder (970) 224-6152 CABLE------------- Comcast---------------------------------- Don Kapperman (970) 567-0425 TELECOM.--------CenturyLink------------------------------- William Johnson (970) 377-6401 WATER------------ City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339 WASTEWATER--City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339 STORMWATER- City of Fort Collins Utilities----------- Wes Lamarque (970) 416-2418 UTILITY PLAN DR1 DRAINAGE EXHIBIT PROJECT LOCATION EX1 EXISTING CONDITIONS & DEMOLITION PLAN BEING A REPLAT OF PORTIONS OF SIDEHILL - FILING TWO, BUCKING HORSE FILING ONE, BUCKING HORSE FILING TWO, AND BUCKING HORSE FILING THREE, LOCATED IN SECTION 20, TOWNSHIP 7 NORTH, RANGE 68 WEST OF THE 6TH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO DEVELOPER/APPLICANT PROJECT TEAM: SITE ENGINEER Northern Engineering Services, Inc. Nick Haws, PE, LEED AP 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 SURVEYOR Northern Engineering Services, Inc. Eric Smith, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 PLANNER/ LANDSCAPE ARCHITECT E N G I N E E R I N G N O R T H E RN E N G I N E E R I N G N O R T H E RN Bucking Horse, LLC Ralph Shields 3702 Manhatten Ave., Suite 201 Fort Collins, CO 80526 (970) 229-5900 Project Datum: NGVD 29 Unadjusted (Old City of Fort Collins Datum) City of Fort Collins Benchmark 4-07 Southwest corner of Timberline Rd. and Bear Mountain Dr. due north of new police building on the southwest corner of a catch basin. Elevation = 4939.66 City of Fort Collins Benchmark 17-92 300 feet south of the southwest corner of East Drake Rd. and Timberline Rd. in the top of an irrigation structure. Elevation = 4935.51 Note: If NAVD 88 Datum is required for any purpose, the following equations should be used. NAVD88 = NGVD29 UNADJUSTED + 3.18' (FOR BM 4-07) NAVD88 = NGVD29 UNADJUSTED + 3.19' (FOR BM 17-92) Basis of Bearings The Northeast line of Tract M, Bucking Horse Filing One as bearing South 49° 38' 07" East (assumed bearing). Russell + Mills Studios Paul Mills, RLA, ASLA 141 S. College Avenue, Suite 104 Fort Collins, CO 80524 (970) 484-8855 OG1 OVERALL GRADING PLAN GEOTECHNICAL ENGINEER Earth Engineering Company, Inc. Lester Litton, PE 4396 Greenfield Drive Windsor, Colorado 80550 (970) 545-3908 Earth Engineering Consultants, Inc Geotechnical Exploration Report Bucking Horse Development - Southeast Project No. 1122025C Date: July 19, 2012 SUBSURFACE EXPLORATION BY: G1-G4 GRADING PLAN No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: MAY 11, 2016 PROJECT: 687-004 Sheet Of 28 Sheets DRAWING FILENAME: D:rojects\687-004\Dwg\687-004_COVR.dwg LAYOUT NAME: CS1 DATE: May 10, 2016 - 3:15pm CAD OPERATOR: luke LIST OF XREFS: [NES-xborder] These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E N G I N E E R I N G N O R T H E RN 05/11/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 www.northernengineering.com Phone: 970.221.4158 - Filing Four russell mills studios + FILING FOUR OU1 OVERALL UTILITY PLAN U1-U4 TRAFFIC ENGINEER Matt Delich, PE Delich Associates 2272 Glen Haven Drive Loveland, Colorado 80538 (970) 669-2061 TRAFFIC & TRANSPORTATION ENGINEERING ST1 SS1 SANITARY SEWER LINE A PLAN & PROFILE SS2 SANITARY SEWER LINE A2, B, & B3 PLAN & PROFILE ST2 STORM DRAIN A PLAN & PROFILE STORM DRAIN B, C, & D PLAN & PROFILE EC1 EROSION CONTROL PLAN D1 SEWER DETAILS D4-D5 DRAINAGE DETAILS EC2 EROSION CONTROL DETAILS D6-D7 SITE DETAILS D2-D3 WATER DETAILS UTILITY SHEETS GRADING SHEETS DRAINAGE & EROSION CONTROL SHEETS DETAIL SHEETS