Loading...
HomeMy WebLinkAboutWEST PLUM HOUSING - FDP - FDP160048 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANS40' FL - FL 20' FL - CROWN 20' FL - CROWN \A1;20' FL - CROWN PROPOSED PLUM STREET (66' ROW) PROPOSED BUILDING 12' TRAVEL LANE 30" VERTICAL CURB & GUTTER 30" VERTICAL CURB & GUTTER EXISTING ±57.5' ROW NORTH RIGHT-OF-WAY 12' TRAVEL LANE 8' BIKE/ PARKING 8' BIKE/ PARKING ADD'L ±8.5' ROW PROPOSED ±66' ROW SOUTH RIGHT-OF-WAY 9' UTIL & ACCESS ESMT EXISTING BUILDING 4' MIN. EXISTING ±43' FL - FL ± 21.5' FL - CROWN ± 21.5' FL - CROWN \A1;%%P 21.5' FL - CROWN PROPOSED CITY PARK AVE (ROW VARIES) PROPOSED BUILDING EXISTING 30" VERTICAL CURB & GUTTER PROPOSED ROW (WIDTH VARIES) EAST RIGHT-OF-WAY 9' UTIL & ACCESS ESMT 7' WALK (5' WITHIN ROW) 8' PARKWAY EXISTING WALK (6' WITHIN ROW) EXISTING 7' PARKWAY 6' WALK (4.5' WITHIN ROW) 8' PARKWAY WEST RIGHT-OF-WAY EXISTING 4' WALK (ATTACHED) No. Revisions: CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner A. GENERAL NOTES 1. All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary G S S T M LID WV H Y D H Y D WV WV E / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X T T T T T T T G G G G G G G G G G G G T T T T T T CTV CTV CTV CTV OHU OHU OHU OHU OHU OHU OHU OHU 9' UTILITY EASEMENT 9' UTILITY EASEMENT 5' UTILITY EASEMENT UTILITY EASEMENT T / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X VAULT ELEC T FO T FO ELEC VAULT ELEC / / / / / / / / / / / / / / / / / / / / / / / / X X X VAULT ELEC VAULT ELEC CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR VAULT ELEC FO VAULT ELEC T FO E X S S T WV H Y D H Y D WV WV / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X T T T T T T T G G G G G G G G G G G G T T T T T T CTV CTV CTV CTV SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W VAULT ELEC S T FO T FO ELEC VAULT ELEC W W ST / / / / / / / / / / / / / / / / / / / / / / / / FO X X G G E E E E E E E F F F E F F S WV H Y D H Y D WV / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X T T T T T T G G G G G G T T T T SS SS SS SS SS SS SS W W W W W W W W V AULT ELEC X T / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X T T T T T T T T T T T T T VAULT ELEC T FO T FO ELEC VAULT ELEC ST / / / / / / / / / / / / / / / / / / / / / / / / X X X VAULT ELEC VAULT ELEC CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR VAULT ELEC FO VAULT ELEC T FO E X X 5030 5035 5040 5045 5050 5030 5035 5040 5045 5050 9+50 10+00 11+00 12+00 13+00 14+00 14+50 5038.22 5037.94 5037.72 5037.54 5037.35 5037.17 5036.99 5036.81 5036.67 5036.53 5036.39 5036.24 5035.94 5035.62 5035.30 5034.98 -1.10% -0.74% 0.34% -1.30% -1.27% -0.56% -0.95% -1.23% -1.25% -1.29% -1.27% -1.28% -1.30% PVI STA = 10+00.00 PVI ELEV = 5038.22 PVI STA = 10+34.67 PVI ELEV = 5037.84 PVI STA = 11+70.88 PVI ELEV = 5036.83 PVI STA = 12+72.14 PVI ELEV = 5036.26 PVI STA = 12+73.26 PVI ELEV = 5036.25 PVI STA = 12+74.14 PVI ELEV = 5036.25 PVI STA = 12+75.26 PVI ELEV = 5036.23 PVI STA = 12+79.81 PVI ELEV = 5036.19 PVI STA = 12+90.88 PVI ELEV = 5036.06 PVI STA = 12+94.81 PVI ELEV = 5036.01 PVI STA = 13+02.97 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C600 UTILITY DETAILS A. Reese B. Ruch N/A No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: Dec. 28, 2016 PROJECT: 1252-001 Sheet of 15 Sheets WEST PLUM HOUSING These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 12/28/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C601 UTILITY DETAILS A. Reese B. Ruch N/A No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: Dec. 28, 2016 PROJECT: 1252-001 Sheet of 15 Sheets WEST PLUM HOUSING These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 12/28/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C602 STORMWATER DETAILS A. Reese B. Ruch N/A No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: Dec. 28, 2016 PROJECT: 1252-001 Sheet of 15 Sheets WEST PLUM HOUSING These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 12/28/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E N G I N E E R I N G N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com NOT TO SCALE 300 C602 STORMWATER BEDDING City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C603 SITE DETAILS A. Reese B. Ruch N/A No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: Dec. 28, 2016 PROJECT: 1252-001 Sheet of 15 Sheets WEST PLUM HOUSING These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 12/28/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E N G I N E E R I N G N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com NOT TO SCALE 400 C603 CURB AND GUTTER UD UD UD UD UD UD X X X X X X X X X X X X X X X V AULT ELEC FO FO ELEC VAULT ELEC ST X X X VAULT ELEC VAULT ELEC CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR VAULT ELEC FO VAULT ELEC FO E X X X X X X D D D TF PLUM STREET (ROW VARIES) 9' UTILITY EASEMENT PROPOSED CONCRETE COLLAR & CHASE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C701 EROSION CONTROL DETAILS A. Reese B. Ruch N/A No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: Dec. 28, 2016 PROJECT: 1252-001 Sheet of 15 Sheets WEST PLUM HOUSING These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 12/28/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 UD UD UD UD UD UD T X X X X X X X X X X X X X X X T T T T T T T T T T T T T V AULT ELEC T FO T FO ELEC VAULT ELEC ST X X X VAULT ELEC VAULT ELEC CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR VAULT ELEC FO VAULT ELEC T FO E X X X X X X D D D TF 1 0.76 PLUM STREET (ROW VARIES) 9' UTILITY EASEMENT PROPOSED CONCRETE COLLAR & CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 5' WALK w/ PAN PROPOSED 1' SIDEWALK CHASE PROPOSED 1' SIDEWALK CHASE PROPOSED 1' SIDEWALK CHASE 9' UTILITY EASEMENT 5' UTILITY EASEMENT UTILITY EASEMENT THE LOFTS AT CAMPUS WEST TOWN SQUARE CONDOMINIUMS CITY PARK CONDOMINIUMS (BOOK 1291, PAGE 862) THE DISTRICT AT CAMPUS WEST (REC. NO. 20130032356) 5' UTILITY EASEMENT PROPOSED STORM DRAIN OPEN BOTTOM DETENTION VAULT 3 2 0.36 2 1 4 0.03 4 PROPOSED OUTLET STRUCTURE PROPOSED TRENCH DRAIN PROPOSED TRENCH DRAIN 3 0.13 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C800 DRAINAGE EXHIBIT A. Reese B. Ruch 1"=20' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: Dec. 28, 2016 PROJECT: 1252-001 Sheet of 15 Sheets WEST PLUM HOUSING These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 12/28/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E N G I N E E R I N G N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com NORTH ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 LEGEND: 4953 PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET DESIGN POINT A FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 1 1 NOTES: 1. REFER TO THE FINAL DRAINAGE REPORT FOR WEST PLUM HOUSING, DATED DECEMBER 28, 2016 FOR ADDITIONAL INFORMATION. BASIN DESIGNATION AREA BASIN (AC) BENCHMARK FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION C 0.60 ac PROJECT DATUM: NAVD88 CITY OF FORT COLLINS BENCHMARK 19-97 AT THE SOUTHEAST CORNER OF WEST ELIZABETH AND SHIELDS ST., ON A CONCRETE TRAFFIC SIGNAL BASE. ELEV.=5025.74 CITY OF FORT COLLINS BENCHMARK 3-08 SOUTHWEST CORNER OF MULBERRY ST. AND SHIELDS ST. ON A CONCRETE TRAFFIC SIGNAL BASE. ELEV.=5030.29 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.17' BASIS OF BEARINGS THE BASIS OF BEARINGS IS THE SOUTH LINE OF THE NORTHEAST QUARTER OF SECTION 15, AS BEARING SOUTH 89°04'20" EAST. DEVELOPED RUNOFF SUMMARY TABLE BASIN ID TOTAL AREA (acres) C2 C10 C100 2-yr Tc (min) 10-yr Tc (min) 100-yr Tc (min) Q2 (cfs) Q10 (cfs) Q100 (cfs) 1 0.76 0.95 0.95 1.00 6.8 6.8 5.7 1.87 3.20 7.35 2 0.36 0.63 0.63 0.79 12.0 12.0 11.4 0.48 0.82 2.14 3 0.13 0.15 0.15 0.19 8.4 8.4 7.9 0.05 0.08 0.21 4 0.03 0.15 0.15 0.19 5.6 5.6 5.2 0.01 0.02 0.06 E N G I N E E R I N G N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com VEHICLE TRACKING CONTROL PAD SHALL BE LOCATED AT EVERY ACCESS POINT TO THE CONSTRUCTION SITE. A SIGN SHALL BE PLACED NEXT TO THE VEHICLE TRACKING CONTROL PAD TO DESIGNATE THE LOCATION AS THE CONSTRUCTION ENTRANCE/EXIT. VEHICLE TRACKING CONTROL PADS SHALL CONSIST OF HARD, DENSE, DURABLE STONE, ANGULAR IN SHAPE AND RESISTANT TO WEATHERING. ROUNDED STONE (i.e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x4'S, PIPES, DIRT, GRAVEL OR ASPHALT, SHALL BE PLACED IN GUTTER TO FACILITATE MOUNTING CURB; HOWEVER, CURB MAY BE CUT DOWN TO A HEIGHT OF 2" OR HIGHER FOR EASIER ACCESS AND REPLACED AT PROJECT COMPLETION. OTHER ACCESS DEVICES MAY BE USED AS ACCEPTED BY THE CITY. 3" - 6" ROCK CURB CUT 50' MIN. 2" MIN. 6" MIN. 6" MIN. ALTHOUGH NOT NORMALLY USED, THE CITY RESERVES THE RIGHT TO REQUIRE VEHICLE TRACKING CONTROL WITH A TEMPORARY CATTLE GUARD AND/OR WHEEL WASH FACILITIES AT SITES WHERE TRACKING ONTO PAVED AREAS BECOMES A SIGNIFICANT PROBLEM AS DETERMINED BY THE CITY INSPECTOR. IF VEHICLE TRACKING CONTROL WITH WHEEL WASH FACILITIES ARE REQUIRED, ALL WHEELS ON EVERY VEHICLE LEAVING THE SITE SHALL BE CLEANED OF MUD USING A PRESSURE-WASHER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A WATER SOURCE AND CONSTRUCTING A WASHWATER SEDIMENT TRAP. 5. 6. IF VEHICLE WHEEL WASH FACILITIES ARE REQUIRED, CONTRACTOR SHALL INSPECT VEHICLE TRACKING CONTROL AND WHEEL WASH FACILITIES DAILY. ACCUMULATED SEDIMENTS SHALL BE REMOVED FROM THE PAD SURFACE. ACCUMULATED SEDIMENT IN THE WASHWATER/SEDIMENT TRAP SHALL BE REMOVED WHEN THE SEDIMENT REACHES AN AVERAGE DEPTH OF 12-INCHES. 4. 5. VTC 0" ON BEDROCK OR HARD SURFACE, 2" IN SOIL ROCK SOCK SECTION ROCK SOCK PLAN 4" TO 6" MAX AT CURBS, OTHERWISE 6"-10" DEPENDING ON EXPECTED SEDIMENT LOADS ROCK SOCK JOINTING \A1;12" \A1;12" {ROCK SOCK INSTALLATION NOTES }1.SEE PLAN VIEW FOR: - LOCATION (S) OF ROCK SOCKS. 2.CRUSHED ROCK SHALL BE 1{}" (MINUS) IN SIZE WITH A FRACTURED FACE (ALL SIDES) AND SHALL COMPLY WITH GRADATION SHOWN ON THIS SHEET (1{}" MINUS). 3.WIRE MESH SHALL BE FABRICATED OF 10 GAGE POULTRY MESH, OR EQUIVALENT, WITH A MAXIMUM OPENING OF {}", RECOMMENDED MINIMUM ROLL WIDTH OF 48". 4.WIRE MESH SHALL BE SECURED USING "HOG RINGS" OR WIRE TIES AT 6" CENTERS ALONG ALL JOINTS AND AT 2" CENTERS ON ENDS OF SOCKS. 5.SOME MUNICIPALITIES MAY ALLOW THE USE OF FILTER FABRIC AS AN ALTERNATIVE TO WIRE MESH FOR THE ROCK ENCLOSURE. GRADATION TABLE SIEVE SIZE MASS PERCENT PASSING SQUARE MESH SIEVES NO. 4 2" 100 1-1/2" 90-100 1" 20-55 3/4" 0-15 3/8" 0-5 MATCHES SPECIFICATIONS FOR NO. 4 COARSE AGGREGATE FOR CONCRETE PER AASHTO M43. ALL ROCK SHALL BE FRACTURED FACE, ALL SIDES WIRE ENCLOSED 1 1/2" WASHED ROCK CURB AND GUTTER TUBULAR MARKER \A1;2' RS NOT TO SCALE 001 C701 CONCRETE WASHOUT AREA NOT TO SCALE 002 C701 ROCK SOCK NOT TO SCALE 003 C701 VEHICLE TRACKING BAG NOT TO SCALE 004 C701 CONSTRUCTION FENCE w/ ROCK SOCKS TEMPORARY CHAIN-LINK FENCE ROCK SOCK TEMPORARY CHAIN-LINK FENCE ROCK SOCK SIDE VIEW CF 1.CONCRETE WASHOUT AREA SHALL BE INSTALLED PRIOR TO ANY CONCRETE PLACEMENT ON SITE. 2.VEHICLE TRACKING CONTROL IS REQUIRED IF ACCESS TO CONCRETE WASHOUT AREA IS OFF PAVEMENT. 3.SIGNS SHALL BE PLACED AT THE CONSTRUCTION ENTRANCE, AT THE WASHOUT AREA, AND ELSEWHERE AS NECESSARY TO CLEARLY INDICATE THE LOCATION OF THE CONCRETE WASHOUT AREA TO OPERATORS OF CONCRETE TRUCKS AND PUMP RIGS. 4.THE CONCRETE WASHOUT AREA SHALL BE REPAIRED AND ENLARGED OR CLEANED OUT AS NECESSARY TO MAINTAIN CAPACITY FOR WASTED CONCRETE. 5.THE CONCRETE WASHOUT SHOULD BE EMPTIED WHEN HALF OF TOTAL HOLDING CAPACITY HAS BEEN REACHED. 6.AT THE END OF CONSTRUCTION, ALL CONCRETE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF AT AN ACCEPTED WASTE SITE. 7.WHEN THE CONCRETE WASHOUT AREA IS REMOVED, THE DISTURBED AREA SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED IN A MANNER ACCEPTED BY THE CITY. 8.LOCATION OF CONCRETE WASHOUT AREA ON SHEET EC1 IS CONCEPTUAL ONLY. FINAL LOCATION TO BE DETERMINED IN THE FIELD AT CONTRACTOR'S DISCRETION. {\LNOTES:} 3H:1V OR FLATTER SIDE SLOPES \A1;12" MIN 8'x 8' MIN OR AS REQUIRED TO CONTAIN WASTE CONCRETE \A1;12" \A1;2'-0" MIN. COMPACTED EMBANKMENT MATERIAL, TYP. BERM AROUND PERIMETER GROUND SURFACE SIGN TO INDICATE THE LOCATION OF THE CONCRETE WASHOUT AREA CWA * IMPERMEABLE LINER MAY BE NEEDED IF GROUND WATER IS ENCOUNTERED. PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 5' WALK w/ PAN PROPOSED 1' SIDEWALK CHASE PROPOSED 1' SIDEWALK CHASE PROPOSED 1' SIDEWALK CHASE 9' UTILITY EASEMENT 5' UTILITY EASEMENT UTILITY EASEMENT THE LOFTS AT CAMPUS WEST TOWN SQUARE CONDOMINIUMS CITY PARK CONDOMINIUMS (BOOK 1291, PAGE 862) THE DISTRICT AT CAMPUS WEST (REC. NO. 20130032356) 5' UTILITY EASEMENT PROPOSED STORM DRAIN DETENTION VAULT CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF RS VTC CWA CF RS RS RS RS RS CF CF CF CF CF CF CF CF CF CF RS RS CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C700 EROSION CONTROL PLAN A. Reese B. Ruch 1"=20' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: Dec. 28, 2016 PROJECT: 1252-001 Sheet of 15 Sheets WEST PLUM HOUSING These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 12/28/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E N G I N E E R I N G N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com NORTH ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 BENCHMARK 1. IT SHOULD BE NOTED THAT ANY EROSION CONTROL PLAN SERVES ONLY AS A GUIDELINE TO THE CONTRACTOR. STAGING AND/OR PHASING OF BEST MANAGEMENT PRACTICES (BMPs) IS EXPECTED. ADDITIONAL AND/OR DIFFERENT BMPs FROM THOSE ORIGINALLY DEPICTED MAY BE NECESSARY DURING CONSTRUCTION DUE TO CHANGING SITE CONDITIONS OR AS REQUIRED BY LOCAL AUTHORITIES. 2. THIS EROSION CONTROL PLAN IS SCHEMATIC IN NATURE. AS SUCH, GRAPHICAL SYMBOLS MAY NOT BE TO SCALE, NOR ARE THEY NECESSARILY SHOWN IN THEIR EXACT LOCATION. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITTING (CITY, STATE DISCHARGE PERMIT, ETC.) AND COMPLIANCE WITH GOVERNING AUTHORITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR (OR PERMIT HOLDER) TO ENSURE EROSION CONTROL MEASURES ARE PROPERLY MAINTAINED AND FOLLOWED. 4. CONTRACTOR SHALL IMPLEMENT THE APPROPRIATE EROSION CONTROL MEASURES ACCORDING THE THE CONSTRUCTION SEQUENCING AND LEVEL OF SITE STABILIZATION. 5. CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR ALL STORM DRAINS, SWALES, PONDS AND RAIN GARDENS UNTIL SITE IS FULLY STABILIZED. 6. CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR DOWNSPOUT CONNECTIONS, TO THE STORM DRAIN SYSTEM, UNTIL CONNECTION IS ESTABLISHED WITH DOWNSPOUT. 7. INLET PROTECTION SHALL BE ADAPTED, AS NECESSARY, TO THE SURROUNDING SURFACE TYPE AND CONDITION (i.e., STAKE-DRIVEN WATTLES FOR BARE SOIL, GRAVEL SOCKS FOR PAVEMENT, ETC.) 8. CONTRACTOR IS RESPONSIBLE FOR STABILIZING ALL SLOPES, PARTICULARLY THOSE STEEPER THAN 6:1. CRIMP MULCHING, HYDRO MULCHING, EROSION MATS, TEMPORARY IRRIGATION, AND ADDITIONAL WATTLES OR SILT FENCING MAY BE NECESSARY TO ESTABLISH VEGETATIVE COVER AND STABILIZE THE SLOPE. 9. CONTRACTOR IS RESPONSIBLE FOR PREVENTING SEDIMENT FROM UNSTABILIZED LANDSCAPE AREAS FROM MIGRATING ONTO AND ENTERING THE PERMEABLE PAVER SYSTEMS UNTIL UPGRADIENT TRIBUTARY AREAS ARE FULLY STABILIZED. 10. ADDITIONAL WATTLES, SILT FENCE, OR OTHER MEASURES, MAY BE NECESSARY TO ENSURE THAT EACH BUILDING PAD IS STABILIZED THROUGHOUT CONSTRUCTION. WATTLES SHALL BE PROVIDED AROUND BUILDING PAD SIDES TO ENSURE AT NO TIME SHALL SEDIMENT BE ALLOWED TO CROSS THE PUBLIC SIDEWALKS. 11. CONTRACTOR SHALL IMPLEMENT APPROPRIATE PERIMETER PROTECTION FOR AREAS DIRECTING DRAINAGE OFFSITE. PERIMETER PROTECTION SHALL BE ADAPTED, AS NECESSARY, TO THE SURROUNDING SURFACE TYPE AND CONDITION (i.e., STAKE-DRIVEN SEDIMENT CONTROL LOGS OR SILT FENCE FOR BARE SOIL, GRAVEL SOCKS FOR PAVEMENT, ETC.) 12. FUELING FACILITIES SHALL BE LOCATED AT LEAST ONE HUNDRED (100) FEET FROM NATURAL BODY OF WATER, WETLAND, NATURAL DRAINAGE WAY OR MANMADE DRAINAGE WAY. THE FUEL TANKS AND FUELING AREA MUST BE SET IN A CONTAINMENT AREA THAT WILL NOT ALLOW A FUEL SPILL TO DIRECTLY FLOW, SEEP, RUN OFF, OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE WAY. 13. CONSTRUCTION WASTE STORAGE (DUMPSTERS) AND PORTABLE SANITATION UNITS (CONSTRUCTION TOILETS) SHALL BE LOCATED AT LEAST FIFTY (50) FEET FROM ANY STORMWATER INLET, WETLAND, OR DRAINAGE WAY. SAID FACILITIES MUST BE SET IN A CONTAINMENT AREA THAT WILL NOT ALLOW POLLUTANTS TO DIRECTLY FLOW, SEEP, RUN OFF, OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE WAY. DUMPSTERS SHALL BE LOCATED ON FLAT, STABLE GROUND, AND CONSTRUCTION TOILETS SHALL BE STAKED DOWN. 14. THE CONTRACTOR AND ALL SUBCONTRACTORS WILL COOPERATE WITH THE CITY'S CONSTRUCTION INSPECTORS BY CEASING OPERATIONS WHEN WINDS ARE OF SUFFICIENT VELOCITY TO CREATE BLOWING DUST WHICH, IN THE INSPECTOR'S OPINION, IS HAZARDOUS TO THE PUBLIC HEALTH AND WELFARE. 15. WHERE SEASONAL CONSTRAINTS (E.G., DURING SUMMER AND WINTER MONTHS) INHIBIT PERMANENT SEEDING OPERATIONS, DISTURBED AREAS WILL BE TREATED WITH MULCH AND MULCH TACKIFIER OR OTHER MATERIALS APPROVED BY EROSION CONTROL STAFF TO PREVENT EROSION. 16. CONTRACTOR SHALL EXERCISE CAUTION TO PROTECT RAIN GARDENS AND MODIFIED RAIN GARDEN FROM SEDIMENTATION. THIS INCLUDES EDUCATING SUBCONTRACTORS ON-SITE. 17. SEE LANDSCAPE PLANS FOR ADDITIONAL INFORMATION ON PLANTING, REVEGETATION, HARDSCAPE AND OTHER PERMANENT SITE STABILIZATION METHODS. 18. DIRT AND DEBRIS FROM CONSTRUCTION ACTIVITIES TRACKED ON CITY STREETS SHALL BE KEPT TO A MINIMUM AND CLEANED NIGHTLY OR AT THE SUGGESTION OF THE CITY'S EROSION CONTROL INSPECTOR. 19. CONTRACTOR SHALL KEEP CONSTRUCTION VEHICLES ENTERING AND EXITING SITE TO A MINIMUM. EROSION CONTROL NOTES: NOTE: ALL BMPS SHOWN ON THIS PLAN ARE GRAPHIC REPRESENTATIONS ONLY. FINAL DETERMINATION OF SIZE AND LOCATION SHALL BE DETERMINED BY THE CONTRACTOR AND DOCUMENTED ON THE DYNAMIC SITE PLAN. 1. CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BY CRIMP MULCHING OR SIMILAR METHODS. 2. TOTAL DISTURBED AREA = 1.38 ACRES 3. SWMP ADMINISTRATOR: Contact ________________________________ Company ________________________________ Address ________________________________ Phone________________________________ 4. CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE WASHOUT AREA IF ACCESS IS OFF PAVEMENT. 5. REFER TO THE FINAL DRAINAGE REPORT FOR WEST PLUM HOUSING, DATED DECEMBER 28, 2016, BY NORTHERN ENGINEERING, FOR ADDITIONAL INFORMATION. GENERAL NOTES: LEGEND: 4953 PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET VEHICLE TRACKING CONTROL PAD CONSTRUCTION FENCE w/ ROCK SOCK CF CONCRETE WASHOUT ROCK SOCK TABLE OF CONSTRUCTION SEQUENCE AND BMP APPLICATION Project: West Plum Housing CONSTRUCTION PHASE MOBILIZATION DEMOLITION GRADING BEST MANAGEMENT PRACTICES (BMPS) Structural "Installation" Flow Barriers (Bales, Wattles, etc.) (RS) UTILITIES INSTALLATION FLAT WORK INSTALLATION VERTICAL INSTALLATION LANDSCAPE DEMOBILIZATION Concrete Washout Area (CWA) * All Temporary BMPs to be Removed once Construction is Complete Vehicle Tracking Pad * (VTC) CWA RS VTC CF PROJECT DATUM: NAVD88 CITY OF FORT COLLINS BENCHMARK 19-97 AT THE SOUTHEAST CORNER OF WEST ELIZABETH AND SHIELDS ST., ON A CONCRETE TRAFFIC SIGNAL BASE. ELEV.= 5025.74 CITY OF FORT COLLINS BENCHMARK 3-08 SOUTHWEST CORNER OF MULBERRY ST. AND SHIELDS ST. ON A CONCRETE TRAFFIC SIGNAL BASE. ELEV.= 5030.29 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.17' BASIS OF BEARINGS THE BASIS OF BEARINGS IS THE SOUTH LINE OF THE NORTHEAST QUARTER OF SECTION 15, AS BEARING SOUTH 89°04'20" EAST. NOT TO SCALE 401 C603 STANDARD DRIVEWAY APPROACH NOT TO SCALE 402 C603 DRAINAGE UNDER SIDEWALK NOT TO SCALE 403 C603 NOT TO SCALE 404 C603 NOT TO SCALE 405 C603 NOT TO SCALE 406 C603 TRUNCATED DOME WARNING FOR ACCESS RAMPS 6" 2"R. 2" 6" 6" 12" 1 1/2"R. 2'-6" 6" 4 1/2" 30" 9" R 0.5" 4.5" 18" 3.63" 21.75" R 0.13" 7" 2" 3.75" 12" ROLL-OVER VERTICAL (LOVELAND) Gutter edge may be tapered or battered. (Typical for all Curb & & Gutter Types) DATE: 03/01/02 CURB AND GUTTER URBAN AREA STREET STANDARDS LARIMER COUNTY CONSTRUCTION DRAWINGS REVISION NO: 1 701 DRAWING NOTES: 1. 6' wide pan for residential streets. 2. All intersections to have access ramps. 3. Standard Curb and Gutter Section, See Standard Drawing 701 4. 0" Curb Height, See Section A-A 5. All of these pedestrian improvements shall be in ROW or a pedestrian or public access easement. 6. Detectable Warning to extend the full width of the ramp and be 2'-0" in the direction of travel. Maximum slope in the direction of travel shall be no more than 5.0 percent (1:20). Material to be approved by local engineer 7. T = 6" for residential and 8" for commercial. 8. Distance from back of curb to the beginning of Detectable Warning cannot be greater than 5'-0" TYPE III DETACHED WALK N.T.S. SECTIONS A-A CLASSIFICATION APPROACH TYPE Single Family 12' 24' Commercial I, II, III, or IV Multi Family 24' 36' 24' 36' MINIMUM WIDTH WIDTH MAXIMUM Industrial 24' 36' I, II, III, or IV I or II RESIDENTIAL: * * * * * DRIVEWAY WIDTHS LARIMER COUNTY DRAWINGS CONSTRUCTION REVISION NO: 1 707.DRAWING 1 STREET STANDARDS URBAN AREA DATE: 02/17/15 STANDARD DRIVEWAY APPROACH (HIGH VOLUME DRIVE TYPE III) High volume driveways (Type III or IV) allowed for 350 or greater trip ends/day. * 30' maximum for 3 car garages. * *No single opening shall exceed 36'. Wider driveways shall be divided w/a median not less than 6' wide. 1/4" per ft. 1" per ft. 1:50 Slope  T Walk 1:50 1:12 (max.) Gutter Parkway Sidewalk Detached 1:12 A A (max) 2' Flare See Note 4 See Note 3 If Concrete Driveway Expansion Joint NOT TO SCALE See Note 6 1/4" per ft. 1" per ft. 1:12 (max.) 1" per ft. Driveway FL See Note 8 I, II, III, or IV Sidewalk Detached or equivalent. (typical both sides) With curb walk, cover plate extends from property line to top of walk face. 6" VERTICAL CURB, GUTTER, AND SIDEWALK SECTION A-A (2 VIEWS) COMBINATION CURB, GUTTER, AND SIDEWALK center, Nelson Standard Anchor 3" #4 Bar Welded at 12" on L = 1 1/4" x 1 1/4" x 1/4" 5/8" Rolled Steel Tread Plate SECTION C-C 1.0' (minimum) approved by the Engineer. Right of Way line to flow line unless 2. Chase and cover plate run from 1. Length of steel plate varies. Notes: Dimension Variable (diamond pattern) 5/8" Rolled Steel Tread Plate 4'-0" or as Directed Retaining Screws at Top of Curb C B A C B PLAN VIEW A Street 10 3/8" SECTION B-B 6" 1 1/4" STANDARD DETAILS FOR DRAINAGE UNDER SIDEWALK STREET STANDARDS LARIMER COUNTY URBAN AREA CONSTRUCTION DRAWINGS DATE: REVISION 04/NO: 01/07 1 709 DRAWING Attached Ft. Collins only Detached Sidewalk finish 12" on center Screw Brass or Electro-galv. 1/2" x 1" Flat Head Mach. threaded to receive screw. Angle iron to be drilled and screw to extend into the Concrete to be drilled to allow Lip of Gutter concrete (typical both sides). (typical both sides) F L Sidewalk X (Varies, See Plans Xmax=2.0') d (Varies, See Plans) ATTACHED SIDEWALK DETAIL Slope sidewalk to curb 1/4" per foot. NOTE: Construct sidewalk with joints at 10' intervals R 1/8" WEAKENED PLANE JOINT EXPANSION JOINT R1/4" and aligned with scoring on curb. INSTALL IN LOCATIONS SPECIFIED IN CHAPTER 22 1/2" 1/4" 1/4 SLAB THICKNESS 1/4" 1/2" Expansion Joint material DETACHED SIDEWALK DETAIL Variable Landscaping Slope sidewalk to curb 1/4" per foot. 2' min. Slope: Minumum 1 4"/ft Maximum 3"/ft CONSTRUCTION SIDEWALK DETAIL LARIMER COUNTY STREET URBAN STANDARDS AREA DRAWINGS 1602 DRAWING REVISION DATE: 04/NO: 01/07 2 02/17/15 STANDARD SIDEWALK URBAN AREA STREET STANDARDS LARIMER COUNTY CONSTRUCTION DRAWINGS REVISION NO: 1601 DRAWING DATE: 4 Driveway Driveway Sidewalk SECTION A-A Detached Sidewalk Attached Sidewalk Detached Attached All Sidewalk Thickness Shall Be 6" minimum. Sidewalk NOTE: 1. Sidewalk grade shall remain consistent across driveway 2. For driveway design requirements, see CONST. DWG. Series 706 & 707 3. This detail applies to Residential & Commercial driveways. 6" 2'-0" 6'-0" T.C. F.L. Lip 1/2" Expansion Joint Material 1/2" Expansion Joint Material 8" Commercial 6" Residential A A Sidewalk Min. NOT TO SCALE 02/17/15 RESIDENTIAL LOCAL STREET ACCESS RAMPS URBAN AREA STREET STANDARDS LARIMER COUNTY CONSTRUCTION DRAWINGS REVISION NO: 3 1606a DRAWING DATE: FORT COLLINS ONLY Notes: 1. Set ramp slopes using the center of the ramp. 2. Truncated dome warning panel: Install panels along with the concrete pour for the ramp. Specifications for the panel material will be provided upon request. 3. Each ramp shall align perpendicular to the street in which the ramp is provided to cross. 4. Refer to standard drawing 1606 in the Laimer County urban area street standards for other necessary criteria needed to construct these ramps that is not specified on this drawing. 5. Construct the ramps and walk so the corner area all drains to the street. 6. If curb and gutter are poured monolithic with ramp, place dome edge at back of curb as shown. If not poured monolithic, place dome edge 6" from back of curb. PLAN VIEW NTS Ramp Flare Gutter Ramp Ramp Flare Curb Curb Conc. Flare Panels Panels Truncated dome panels: 1-2'x2.5' 1-2'x2' Truncated Dome Warning Detection Plan Locations LEGEND: BOC- Back of curb ⅊ Property Line PT - Point of Tangency Flow line Section A-A NTS 4'-6" 2'-6" 2'-0" 2'-0" t Varies Varies 4.5' 6.0' .5' 1.5' 4.5' 1.5 ' 12.0' 12.0' 4.5' .5' 4.5' 6.0' Landscaped Area PT Curb A A 6" Curb (TYP) 0" Curb Full height curb Truncated dome warning detection ⅊  PT of walk R15.0' ⅊ ⅊ & BOW 5'-6" BOC to walk w/ vertical curb 5'-7" BOC to walk w/ drive over curb Conc. Sidewalk Area to be landscaped Conc. walk Gutter or Apron Truncate Dome Warning Panel 1:12 Max slope 1:20 Slope PT of curb return 6" Conc. Flare 6" Curb (TYP) NOT TO SCALE See note 6 02/17/15 TRUNCATED DOME WARNING FOR ACCESS RAMPS URBAN AREA STREET STANDARDS LARIMER COUNTY CONSTRUCTION DRAWINGS REVISION NO: 3 1607 DRAWING DATE: Curb Flare Varies Curb Flare Ramp Curb Curb Flare Ramp Varies Panels Panels 6" Ramp Width: 4.5' 5.0' 6.0' 7.0' 8.0' Note: Truncated dome panels are available in 2'x2' squares and 2'x2.5' rectangles. Combine the widths to fit the ramp. Panels may be cut to no less than a 2'x1.5' size. Panel Width Combinations: 2'+2.5' 2.5'+2.5' 2'+2'+2' 2.5'+2'+2.5' 2'+2'+2'+2' Notes: 1. Truncated dome warning panel: Install panels along with the concrete pour for the ramp. Specifications for the panel and installation instructions will be provided upon request. 2. This drawing shows vertical curb. For Drive Over Curb the warning detection location shall be placed in the same position 6" back from the back of curb. 3. If curb and gutter are poured monolithic with ramp, place dome edge at back of curb as shown. If not poured monolithic, place dome edge 6" from back of curb. Case 1-Directional Ramps Case 2-Non-Directional Ramps Varies Panels Ramp Panels Flare Curb Case 3-Mid-Block Ramps 6" Panels Panels Flare 6" Flare Varies FORT COLLINS ONLY Aligned with Pedestrian flow Gutter or Apron ℄Center line of ramp BOC-Back of Curb FOC -Face of Curb -Flow line Varies 2'-0" 2'-0" A A FOC or ℄ 2'-0" BOC BOC 1:20 1:12 max slope slope Panels embedded in the concrete ramps Section A-A (Center line of ramp) NTS Flow line Curb and Gutter BOC NOT TO SCALE See Note 3 STANDARD SIDEWALK SIDEWALK DETAIL RESIDENTIAL LOCAL STREET ACCESS RAMPS 6 IN. SEE DETAIL 'A' BOLT LAYOUT PER MANUFACTURER B B A A 12" WIDE COVER (SEE DETAIL ABOVE) FRAME AND ANCHORING BY MANUFACTURER 12" WIDE COVER (COORDINATE w/ OWNER AND LANDSCAPE ARCH.) 1 8 IN. PER FT. SLOPE NOTES: 1. CONFIRM FRAME AND GRATE DIMENSIONS WITH MANUFACTURER PRIOR TO POURING CONCRETE CHASE. 2. DEPTH OF CHASE VARIES BY 1 2 IN. TO PROVIDE 1 8 IN. PER FOOT SLOPE ALONG CHANNEL BOTTOM. SIDEWALK ISOMETRIC VIEW SECTION A-A DETAIL 'A' SECTION B-B 4'-6" 6" 3'-0" SEE NOTE 1 6" 2 1 2 1 DECORATIVE IRON GRATE VARIES, 6" TYP. FRAME AND MOUNTING HARDWARE BY MANUFACTURER (SEE DETAIL A) COBBLE SWALE 1' CHASE 1' CHASE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NOT TO SCALE 407 C603 TYPICAL PASS-THROUGH SIDEWALK CHASE NOT TO SCALE 301 C602 CURB, GUTTER AND SIDEWALK NOT TO SCALE 302 C602 METAL SIDEWALK CULVERT FOR VERT. CURB & GUTTER AND DETACHED SIDEWALK-OUFALL TO CURB NOT TO SCALE 302 C602 CLASS B BEDDING LOWER LIMIT OF UNIFORM GRADED CLASS A BEDDING LOWER LIMIT OF LOWER LIMIT OF MATERIAL TRENCH WIDTHS SHALL BE AS SPECIFIED ON PLANS. REFER TO THE STORM SRAINAGE CONSTRUCTION STANDARDS, SECTION 6, "BEDDING MATERIALS" FOR GRADATIONS. SUBDRAIN DETAIL TRENCH WIDTH AS SPECIFIED TRENCH WIDTH AS SPECIFIED ROCK EXCAVATION TRENCH WIDTH AS SPECIFIED GRANULAR MATERIAL UNSTABLE SUBGRADE TRENCH WIDTH AS SPECIFIED ROCK 1 1/2 IN. COMPACTED GRANULAR OR TRENCH WALL SLOPE COMPACTED MATERIAL GRANULAR %%UNOTES: 2. 1. 6 IN. MIN. 4 IN. MIN. \A1;1/8 PIPE O.D. OR 4 IN. MIN. SLOTTED PIPE PERFORATED OR GRAVEL FILTER BACKFILL COMPACTED DENSELY TRENCH WIDTH AS SPECIFIED CLASS C BEDDING TRENCH WIDTH AS SPECIFIED \A1;1/4 PIPE O.D. SLOPE MATERIAL COMPACTED TRENCH DENSELY WALL \A1;PIPE O.D. + 8 IN. \A1;1/4 PIPE O.D. MATERIAL COMPACTED DENSELY SLOPE TRENCH WALL MATERIAL \A1;PIPE O.D. OR 6 IN. MIN. \A1;1/8 PIPE O.D. 3000 CONCRETE P.S.I. TRENCH WALL LOWER LIMIT OF UNIFORMLY SELECTED GRADED SLOPE GRADED COMPACTED ROCK OR MATERIAL GRANULAR COMPACTED \A1;PIPE O.D. TRENCH WALL LOWER LIMIT OF SLOPE COMPACTED DENSELY FILTER 6 IN. MIN. \A1;PIPE O.D. \OR A1;4 1/IN. 8 PIPE MIN. O.D. \A1;PIPE O.D. BROKEN LARGE (IF CONCRETE, REQUIRED) STONES, ETC. MATERIAL LOWER LIMIT OF TRENCH WALL SLOPE APPROVED: DATE: DETAIL DRAWN BY: FORT COLLINS CONSTRUCTION STORMWATER DETAILS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 STORMWATER BEDDING REQUIREMENTS 1/12/00 D-1 SKC APPROVED: DATE: DETAIL DRAWN BY: FORT COLLINS CONSTRUCTION STORMWATER DETAILS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 CURB, GUTTER AND SIDEWALK DETAILS 11/13/00 D-6 NBJ DRIVE-OVER CURB, GUTTER AND SIDEWALK VERTICAL 6 IN. CURB, GUTTER AND SIDEWALK DUMMY JOINT FOR WALKS COMBINATION CURB, GUTTER AND SIDEWALK "HOLLYWOOD" (OBSOLETE - FOR REPLACEMENT ONLY) EDGED 1/8 IN. R. 1/8 IN. 3/4 IN. MIN. SURFACE 4 FT. MIN. .30 FT. 6 IN. .11 FT. .09 FT. 4.43 FT. 1.18 FT. .58 FT. 2.67 FT. 6 IN. 12 IN. 6 IN. 2 FT 6 IN. 2 IN. 6 IN. 1 1/2 IN. 4 1/2 IN. 1 1/2 IN. R 2 IN. R WHERE WALK ADJOINS A CURB, IT SHALL BE CONSTRUCTED 1/4 INCH ABOVE THE CURB. SLOPE SIDEWALK TO CURB - 1/4 IN. TO 1/2 IN. PER FT. 6 IN. 1 3/8 IN. (.11 FT.) 3 3/8 IN. (.28 FT.) 18 IN. (1.5 FT.) (1.5 FT.) 18 IN. (1.17 FT.) LIMITS OF C & G (1.42 FT.) (3.75 FT.) 3 FT. 9 IN. FLOW LINE (1.33 FT) 16 IN. R (1.33 FT.) 16 IN. R 6 IN. 1 1/2 IN. APPROVED: DATE: DETAIL DRAWN BY: STORMWATER CONSTRUCTION DETAILS FORT COLLINS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 D. MOGEN 7/30/2013 D-10B METAL SIDEWALK CULVERT FOR VERT. CURB & GUTTER AND DETACHED SIDEWALK - OUTFALL TO CURB 2 1 2 1 \A1;6" \A1;6" \A1;VARIES \A1;\A1;3' 2' SECTION B-B DETAIL 1 SECTION A-A PLAN SECTION C-C SLOPE \A1;VARIES VARIES 0.5% SLOPE \A1;VARIES (MIN.) \A1;2' DEPRESSED GUTTER \A1;VARIES \A1;3'-3" \A1;2' OPENING \A1;3'-3" \A1;6" (TYP.) \A1;3" (TYP.) \A1;3' (TYP.) SIDEWALK (TYP.) \A1;VARIES \A1;VARIES SLOPE C C B B A A \A1;8'-6" \A1;\A1;6" 2' CONCRETE SIDEWALK w/ PAN CAD FILE NAME: DETAILS DRAWN BY: T. COX D46.dwg OUTLET STRUCTURE DATE DRAWN: 8/15/05 C C A A B B CONTROL PLATE \A1;Ls \A1;3'-6" (MIN.) \A1;6" \A1;Ws \A1;6" \A1;6" \A1;VARIES \A1;VARIES \A1;6" \A1;Ws/2 \A1;Ws/2 OUTLET CENTERLINE PIPE OF SECTION C-C SECTION A-A SECTION B-B WELL SCREEN FLOW CONTROL PLATE ##4@4@12" 12" #4@18" #4@12" \A1;2'-6" #4L@12" #4@12" \A1;6" Wo \A1;Wo \A1;\A1;Wp Wo (Wo+6") \A1;4" (TYP.) TABLE 3" (TYP.) 1/4" (MIN.) THICK STEEL FLOW CONTROL PLATE STAINLESS STEEL ANCHOR BOLT (TYP.) (MAX.) INTO CONCRETE SIDES STEEL CHANNEL FORMED 3/8"x1" FLAT BAR HOLDING FRAME INTERMITTANT WELDS ON TOP AND SIDES STAINLESS STEEL ANCHOR BOLTS OR PLATE FLOW CONTROL END OPTIONAL OF WING CONCRETE WALL) WING WALL (TYP.) 51"x51" GRATING (3/8" ROUND OR TWISTED CROSS BARS AT 3" O.C., WELDED TO 1"x3/8" BEARING BARS AT 2 1/2" O.C.) 3/8" ROUND OR TWISTED CROSS BAR BAR 1"x3/BEARING 8" PLAN \A1;6" \A1;3" CLR. 3" CLR. 3" CLR. TO FASTEN GRATE DOWN \A1;3/8"x6" THREADED BOLT D1 4 OR 3 4. ALL TRASH RACKS SHALL BE MOUNTED USING STAINLESS STEEL HARDWARE AND PROVIDED WITH HINGED AND LOCKABLE OR BOLTABLE ACCESS PANELS. 5. TRASH RACKS SHALL BE STAINLESS STEEL, ALUMINUM, OR STEEL. STEEL TRASH RACKS SHALL BE HOT DIP GALVANIZED AND MAY BE HOT POWDER PAINTED AFTER GALVANIZING. 3 1/2" x1 1/2" KEY OUTLET PIPE 4% 4% CLR. 3" BAR #4 HOOP PIPE CONCRETE METAL OR F LAP 12" #4@12" O.C. O.C. #4@12" CONCRETE SHALL BE CLASS B. MAY BE CAST-IN-PLACE OR PRECAST. GENERAL NOTES 1. 2. 3. STEPS SHALL BE PROVIDED WHEN VERTICAL DIMENSION EXCEEDS 3'-6" AND SHALL BE IN ACCORDANCE WITH AASHTO M 199. HAVE A MINIMUM 2" CLEARANCE. REINFORCING BARS SHALL BE EPOXY COATED AND DEFORMED, AND SHALL #4 DIAGONAL (TYP.) SECTION D-D HOLE (TYP.), SEE ELEV. B ELEV. A ELEV. C WQ WATER QUALITY 100-YEAR OUTLET D D CONCRETE OF OPTIONAL PAD WING WITH WALLS USE ELEV. A (POND INV.) ELEV. B (WQCU ELEV) ELEV. C SPILL ELEV. WQ HOLE DIA. # OF COLUMNS # OF ROWS SECTION LINE A-A (ARROWS A A POINT IN DIRECTION SECTION OPP. OPPOSITE CLR. CLEARANCE ABBREVIATIONS MINIMUM MAXIMUM ON CENTER DIAMETER TYPICAL WIDTH OF CONCRETE OPENING WIDTH OF PLATE NUMBER @ AT # Wp Wo TYP. DIA. O.C. MAX. LEGEND WATER QUALITY (WQ) WQ WATER QUALITY D WQ INV. INVERT ELEV. ELEVATION \A1;6" Ls Ws AND PAD (END OF PAD TO MATCH \A1;6" CONCRETE DOWEL WITH PAD USE OF Ls LENGTH OF STRUCTURE Ws WIDTH OF STRUCTURE Wo (12" MIN.) STEEL OR EQUAL) (NOTE 5) TRASH RACK (U.S. FILTER STAINLESS WELL SCREEN NO. 93 TRASH RACK STEEL OR EQUAL) (U.S. FILTER STAINLESS WELL SCREEN NO. 93 EQUAL) FILTER STAINLESS NO. 93 (U.S. WELL SCREEN STEEL OR DETAIL D-46 INVERT OF PLATE HOLES TO BE AT BOTTOM ROW OF LAST DATE REVISED: 4/7/11 3/8"x6" THREADED BOLT TO FASTEN GRATE DOWN GRATE (TYP. OPP. SIDE) 2 1/4" FROM EDGE OF TO HOLD HINGE IN PLACE, 3/8"x6" BOLTS 12" O.C. FLOW TO COVER OPENING (FASTEN WITH 3/8"x6" TREADED 1/4" METAL BOLTS) PLATE TO GRATE, WITH TO GRATE, WITH (TYP. OPP. SIDE) GRATE (TYP. OPP. SIDE) 2 1/4" FROM EDGE OF TO HOLD HINGE IN PLACE, 3/8"x6" BOLTS 12" O.C. 1/4" PLATE, WELDED 1/4" PLATE, WELDED STORMWATER CONSTRUCTION DETAILS (970) 221-6700 P.O. BOX 580, FORT COLLINS, CO. 80522 CITY OF FORT COLLINS UTILITIES EXTERIOR WALL NOT TO SCALE 305 C602 ORIFICE PLATE ORIFICE OPENING (6.25" Ø) PLATE CENTERED OVER PIPE OPENING IN WALL 1 2" Ø HOLES FOR 3 8" Ø EXPANSION BOLTS EMBEDDING 2" INTO CONCRETE WALL @ 6" O.C. MIN. 5 16" THICK GALVANIZED STEEL PLATE D D+4" D+4" ORIFICE INVERT SHALL MATCH PIPE INVERT NOT TO SCALE 303 C602 OUTLET STRUCTURE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NOT TO SCALE 304 C602 CONCRETE COLLAR 4" 4" R2" 4" 4" R2" 6" OUTLET PIPE FRONT VIEW SIDE VIEW 1' 4' 1" 2.00% 8.33% 6" 5036.05 5037.05 5038.05 N/A 4' 4' 12" 3/8" 3 1 E N G I N E E R I N G N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com NOT TO SCALE 200 C601 BEDDING REQUIREMENTS NOT TO SCALE 201 C601 STANDARD MANHOLE COMPACTED GRANULAR MATERIAL CONFORMING TO CDDH #67 LOWER LIMIT OF TRENCH WALL SLOPING INITIAL LIFT * 12 IN. MIN. PIPE O.D. 4 IN. MIN. TRENCH WIDTH AS SPECIFIED IN SECTION 02221 COMPACTED GRANULAR MATERIAL CONFORMING TO CDDH #67 * DATE REVISED: SEWER CONSTRUCTION DETAILS APPROVED: DRAWN BY: DETAIL BEDDING REQUIRMENTS WW-1 NBJ 4/11/11 ALTERNATE BASE POURED INVERT PRECAST MANHOLE BASE 2 IN. MIN. SLOPE 1 IN. MIN. 8 IN. MIN. 6 IN. 15 IN. OR LESS 48 IN. 18 IN. TO 30 IN. 60 IN. OVER 30 INCHES 72 IN. MIN. MANHOLE MINIMUM INSIDE DIAMETER OF DIAMETER MANHOLE SHALL BE AS FOLLOWS: PIPE SIZE 5 FT. MIN. DEPTH CONCRETE ADJUSTMENT SHIMS GROUTED INSIDE ASTM C-478 ECCENTRIC CONE PRE-FORMED PLASTIC GASKET ASTM C-478 MANHOLE SECTIONS GROUT BASE TO BARREL SECTION ON INSIDE PRE-FORMED PLASTIC GASKET CAST-IN-PLACE CONCRETE BASE 16 IN. MAX. FINISHED GRADE 30 IN. MIN. 48 IN. MAX. VARIABLE 28 IN. MAX. 24 IN. SEE TABLE 6 IN. 12 IN. SLOPE 1 IN./FT. 18 IN. MAX. MANHOLE RUNGS 12 IN. O.C. 8 IN. MIN DATE REVISED: SEWER CONSTRUCTION DETAILS APPROVED: DRAWN BY: DETAIL STANDARD MANHOLE WW-3 NBJ 4/11/11 NOT TO SCALE 202 C601 TRAFFIC RATED CLEANOUT W/ SEWER STAMPED ON LID VALVE BOX \A1;6" MIN \A1;WATER TIGHT SCREW CAP \A1;4" HARD ASPHALT SURFACE OR OTHER FLOW DIRECTION DATE REVISED: SEWER CONSTRUCTION DETAILS APPROVED: DRAWN BY: DETAIL TRAFFIC RATED CLEANOUT WW-15 NBJ 4/11/11 E N G I N E E R I N G N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com NOT TO SCALE 100 C600 WATER MAIN BEDDING BOTTOM OF PIPE AND A MINIMUM OF 12 INCHES ABOVE TOP OF PIPE. GRANULAR BEDDING MATERIAL SHALL BE A MINIMUM OF 4 INCHES BELOW INITIAL 12 IN. LIFT MIN. PIPE O.D. 4 IN. MIN. GRANULAR MATERIAL BEDDING ZONE %%UNOTE: * INITIAL LIFT SHALL NOT EXCEED 2 FEET IN DEPTH. TRENCH WALL LOWER LIMIT OF SLOPING TRENCH IN WIDTH SECTION AS 02221 SPECIFIED * REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 WATER MAIN BEDDING REQUIREMENTS (DIP & PVC) 1 4/8/11 PIPE SIZE BENDS TEE OR DEAD END 22 1/2%%D 45%%D 90%%D 6" 8" 12" 1.0 1.5 3.0 1.5 2.5 4.5 2.5 4.5 9.0 4.5 8.0 16.5 3.5 5.5 12.0 MINIMUM BEARING SURFACE AREA (SQ. FT.) Bearing surface areas shown in chart are minimum. All fittings to be wrapped with polyethylene. Pipe installed under conditions different from those normally encountered shall require thrust blocks designed for those particular conditions. Thrust blocks on pipe larger than 16 inches diameter shall be designed for conditions existing at the installation site. Refer to Section 03300 for concrete requirements. 1. 2. 3. 4. 5. GENERAL NOTES: UNDISTURBED SOIL POLYETHYLENE BOND BREAKER UNDISTURBED SOIL BOND BREAKER POLYETHYLENE BEARING SURFACE POLYETHYLENE BOND BREAKER UNDISTURBED SOIL BEARING SURFACE SOIL UNDISTURBED BEARING SURFACE POLYETHYLENE BOND BREAKER BEDDING MATERIAL 2/3 DIA. %%UTEE %%UTYPICAL BEND %%UTYPICAL CROSS-SECTION %%UDEAD END BEARING SURFACES ARE A MINIMUM REQUIREMENT AND DO NOT RELIEVE DESIGN ENGINEER OF RESPONSIBILITY TO DESIGN EACH THRUST BLOCK. 16" 4.8 9.6 18.9 34.7 24.5 REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 STANDARD CONCRETE THRUST BLOCKS 2 4/8/11 DESIGNATED SPRINKLER SERVICE FLOW 5 FT. MIN. METER PIT AIR-INJECTION PORT (TOP OF PIPE MAX. 1/4" PIT METER 5 FT. MIN. FLOW SPRINKLER TAP OFF DOMESTIC SERVICE SERVICE MAIN VACUUM BREAKER VACUUM BREAKER (FROM OUTLET SIDE OF METER PIT TO SHUT-OFF VALVE TEE) IRRIGATION SHUT-OFF VALVE AIR-INJECTION PORT DOWNSTREAM OF VACUUM BREAKER SPRINKLER TEE) METER PIT TO (FROM OUTLET SIDE OF (STOP AND WASTE VALVE NOT PERMITTED) IRRIGATION SHUT-OFF VALVE (STOP AND WASTE VALVE NOT PERMITTED) DIA. WITH CAP OR PLUG) AIR-INJECTION PORT (TOP OF PIPE MAX. 1/4" DIA. WITH CAP OR PLUG) (3/4" OR LARGER RECOMMENDED) RECOMMENDED) (3/4" OR LARGER PORT DOWNSTREAM OF VACUUM BREAKER AIR-INJECTION REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 SPRINKLER SYSTEM DETAIL 13 8/4/15 GENERAL NOTES: 1/4" HOLE IN HANDLE 1 1/2" BALL VALVE 6. %METER %INSTALLATION UPLAN DESIGN FOR 6 VIEW IN. AND LARGER METERS SHALL BE DETERMINED BY THE 1 1/UTILITY. 2" CAP 5. FOR IRRIGATION ONLY SERVICES, NO BYPASS ALLOWED. 4. 3. GATE VALVES MUST OPEN RIGHT AND BE EPOXY COATED, RESILIENT SEAT WITH A HAND WHEEL ASSIST. ALL PIPING WITHIN VAULT SHALL BE D.I.P. WITH FLANGED FITTINGS, EXCEPT FOR THE SOLID SLEEVES. 2. ALL JOINTS OUTSIDE OF VAULT SHALL BE RESTRAINED MECHANICAL JOINTS. (REFERENCE SECTION 02615) 1. THE BUILDING IMMEDIATELY FOLLOWING THE MAIN SHUT OFF VALVE. IF A PRESSURE REDUCING VALVE IS REQUIRED BY PLUMBING CODE, INSTALL VALVE INSIDE 7. LOCATION AND ALIGNMENT OF AMR POD(S) ON VAULT TOP CAN VARY. %%UTEST-TEE SIDE VIEW SEE DETAIL TEST-TEE BELOW LID) 24" DIA. FOR H-20 BRIDGE LOADING PRECAST CONCRETE VAULT DESIGNED STRAINER 7'-0" 1'-6" 2'-6" METER (PLACED FLOW SLEEVE SOLID VALVE VALVE GATE GATE SLEEVE SOLID 8'-6" AMR POD(S) (FORD YOKE BOX PART #YUC-7 WITH FORD YOKE BOX LID PART #YL-TP WITH 1 27/32" DIA. HOLE AND REMOVABLE PLUG) ANCHOR RODS PROTECTIVE COATING (TYP.) WITH GATE VALVE FLOW FLOW FLOW ACCESS OPENING LADDER RUNG VAULT ACCESS PRECAST CONCRETE OR FOOTING CAST IN PLACE 18" DIA. PERFORATED PIPE SUMP 8. A SEPERATE AMR POD MUST BE INSTALLED FOR EACH METER REGISTER. REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 STANDARD SETTING FOR 3 IN. AND 4 IN. WATER METERS (PLAN VIEW) 17A 4/11/11 1. DO NOT INSTALL IN ANY STREET, ALLEY, PARKING AREA, DRIVEWAY, SIDEWALK DRAINAGE DITCH OR DETENTION BASIN. 2. NO LANDSCAPING (SHRUBS, BOULDERS, ECT.) OR STRUCTURES TO BE WITHIN 4 FT. OR TREES WITHIN 10 FT. OF METER VAULT. 3. SLOPE GROUND SURROUNDING METER VAULT AWAY FROM LID AT 2%%% GRADE OR GREATER. 4. MAKE NO PLUMBING CONNECTIONS (TEES, COUPLINGS, ECT.) IN METER VAULT. 5. GRADE ACCEPTANCE AFTER METER PIT INSTALLATION REQUIRES THAT THE OWNER ADJUST METER VAULT COVER TO 1/2 IN. ABOVE FINAL GRADE. 6. IF A PRESSURE REDUCING VALVE IS REQUIRED BY PLUMBING CODE, IT SHALL BE INSTALLED INSIDE THE BUILDING, IMMEDIATELY FOLLOWING THE MAIN SHUT-OFF VALVE. GENERAL NOTES: ADJUSTABLE PIPE SUPPORT UNDER VALVES AND METER 3/4" TO 1-1/2" GRAVEL ASPHALTIC GROUT SOLID PAVING BRICK (TYPICAL) PRE-FORMED PLASTIC GASKETS PIPE ENCASED WITH MASTIC GATE VALVE STRAINER SOLID SLEEVE GATE VALVE MANHOLE RUNGS 12 INCHES O.C. FINISHED GRADE 2% SLOPE INSTALL LID 1/2" ABOVE FINAL GRADE ALUMINUM MANHOLE COVER AND RING WITH LID LOCK MORTAR OR LIFTING HOOK MASTIC FLOW BLOCK-OUT TO BE GROUTED 54" (MIN.) 6" (MAX.) 7" (MIN.) 16" (MAX.) GRADE PRE-RINGS CAST CONCRETE (IF REQUIRED) 10" 30" 8" 8" (TYPICAL) ANCHOR RODS (TYP.) WITH PROTECTIVE 1" (MAX.) CONDUIT THROUGH INTO YOKEBOX VAULT OR PIT TOP 1/2" EMT OR PVC 3" (MAX.) AND REMOVABLE PLUG) YOKE WITH PART BOX #1 YUC-27/LID 32" 7 PART WITH DIA. HOLE FORD #YL-TP AMR POD (FORD YOKE BOX FINISHED GRADE BE 1/2" ABOVE TOP OF AMR LID TO 2' 3/4" ROCK FOR GRADE ADJUSTMENT (MAX.) (IF REQ'D) (TYP.) (TYP.) 66" (MAX.) 12" (TYP.) PRECAST OR CAST IN PLACE CONCRETE FOOTING (TYP.) PIPE 18" SUMP DIA. PERFORATED REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 STANDARD SETTING FOR 3 IN. AND 4 IN. WATER METERS (SIDE VIEW) 17B 4/11/11 COATING SERVICE LINE BY-PASS 30" 54" (MIN.) 8" 8" 10" 6" (MAX.) 12 INCHES MANHOLE O.RUNGS C. AND RING WITH LID LOCK ALUMINUM MANHOLE COVER MORTAR OR MASTIC PRE-CAST GRADE CONCRETE RINGS (IF PLASTIC GASKETS PRE-FORMED LIFTING HOOK REQUIRED) 3/4" TO 1-1/2" GRAVEL PRECAST OR CAST IN PLACE CONCRETE FOOTING (TYP.) (TYP.) 66" (MAX.) 12" (TYP.) REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 STANDARD SETTING FOR 3 IN. AND 4 IN. WATER METERS (END VIEW) 17C 4/11/11 CP TEST STATION U S A \A1;1 1/8" 7/16" 3 1/2" 7 5/16" 5/2" 8" A S U I E J W STATION LOCATOR LID PLAN VIEW LID SECTION VIEW VALVE BOX SECTION VIEW 9" 6 1/8" 10" \A1;7 9/16" 2 1/16" CLOSED PICKHOLE (TYPICAL OPPOSITE SIDE) 1/2" RAISED LETTERING (RECESSED FLUSH) REFERENCE SPECIFICATIONS 02622-2 THROUGH 02622-4 FOR LOCATOR FOR CP TEST STATION INFORMATION. REFERENCE SPECIFICATIONS 16640-5 STATION BOX INFORMATION. REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 CP TEST AND LOCATOR STATION BOX 25 W J E I NOT TO SCALE 101 C600 STANDARD CONCRETE TRUST BLOCKS NOT TO SCALE 102 C600 SPRINKLER SYSTEM DETAIL NOT TO SCALE 103 C600 STANDARD SETTING FOR 3 IN. AND 4 IN. WATER METERS (PLAN VIEW) NOT TO SCALE 104 C600 NOT TO SCALE 105 C600 NOT TO SCALE 106 C600 STANDARD SETTING FOR 3 IN. AND CP TEST AND LOCATOR STATION BOX 4 IN. WATER METERS (SIDE VIEW) STANDARD SETTING FOR 3 IN. AND 4 IN. WATER METERS (END VIEW) PVI ELEV = 5035.90 PVI STA = 13+20.33 PVI ELEV = 5035.68 PVI STA = 13+38.65 PVI ELEV = 5035.45 PVI STA = 13+75.31 PVI ELEV = 5034.97 EXISTING GROUND PROPOSED GRADE PROPOSED GRADE EXISTING GROUND / / / / / / / / / / / / / / / / / / / / / / / / T T T T T T T VAULT ELEC VAULT ELEC ST X VAULT ELEC CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR D D D TF PLUM STREET (ROW VARIES) CITY PARK AVENUE 5' CURB TRANSITION 7' SIDEWALK 9' UTILITY EASEMENT ±40' - 66' ROW EXISTING 30" VERTICAL CURB & GUTTER PROPOSED 30" VERTICAL CURB & GUTTER PAVEMENT MILL & OVERLAY AREA NEW PAVEMENT AREA LIMIT OF MILL & OVERLAY LIMIT OF MILL & OVERLAY EXISTING STRIPING TO BE REPLACED EXISTING 30" VERTICAL CURB & GUTTER 7' SIDEWALK 9' UTILITY EASEMENT LIMIT OF NEW PAVEMENT DETENTION OUTFALL SEE SHEET C301 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C500 PLAN & PROFILE WEST PLUM STREET A. Reese B. Ruch 1"=20' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: Dec. 28, 2016 PROJECT: 1252-001 Sheet of 13 Sheets WEST PLUM HOUSING These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 12/28/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E N G I N E E R I N G N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com NORTH ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 3. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 4. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN, AND RECOMMENDATIONS. LEGEND: PROPOSED CURB & GUTTER PROPOSED EASEMENT LINE PROPERTY BOUNDARY EXISTING FENCE X RIGHT FLOWLINE WEST PLUM STREET SCALE : 1" = 20' (H) 1" = 5' (V) PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED PEDESTRIAN ACCESS RAMPS ASPHALT MILL & OVERLAY ASPHALT PATCH X X X X D D D TF UD UD UD UD UD UD PLUM STREET (ROW VARIES) 5' UTILITY EASEMENT UTILITY EASEMENT 5' UTILITY EASEMENT PROPOSED CONCRETE COLLAR & CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 5' WALK w/ PAN PROPOSED 1' SIDEWALK CHASE PROPOSED 1' SIDEWALK CHASE PROPOSED 1' SIDEWALK CHASE 9' UTILITY EASEMENT THE LOFTS AT CAMPUS WEST TOWN SQUARE CONDOMINIUMS CITY PARK CONDOMINIUMS (BOOK 1291, PAGE 862) THE DISTRICT AT CAMPUS WEST (REC. NO. 20130032356) OPEN BOTTOM DETENTION VAULT FFE=41.25 FFE=39.30 FFE=41.25 PATIO=40.87 FFE= 39.81 FFE=39.69 41.22 41.21 39.88 38.63 37.72 37.07 36.97 36.97 36.37 35.89 35.05 35.83 35.26 36.01 35.75 36.57 36.73 37.03 36.89 36.20 35.58 34.97 36.25 36.32 37.50 36.07 37.66 39.71 38.43 38.61 37.43 37.55 38.40 38.61 39.11 38.16 38.89 38.93 38.28 38.90 39.01 39.61 39.67 39.94 40.76 38.22 40.65 36.83 40.65 38.60 38.31 38.70 (40.01) 40.66 40.86 40.94 40.99 40.75 40.64 39.74 40.87 39.03 39.03 39.30 39.49 39.59 38.99 39.30 37.31 36.64 37.63 37.53 41.13 41.17 40.16 40.75 40.58 40.58 41.88 41.87 39.44 39.06 40.12 40.44 39.32 39.20 38.98 40.51 40.51 39.80 39.31 39.27 38.75 38.79 38.26 38.22 37.95 38.09 36.42 36.23 36.28 (35.09) (35.63) (35.79) 40.32 (40.58) (40.61) 40.48 1.0% 0.5% (39.02) PROPOSED 6' SIDEWALK PROPOSED 7' SIDEWALK 44' - 40' - 38.46 38.36 5' CURB TRANSITION 39.81 (36.80) (35.62) (36.00) (40.93) TIE TO EXISTING SIDEWALK R20' R15' R15' 36.92 36.54 43.55 42.02 TIE TO EXISTING SIDEWALK 7-RISERS 7-RISERS 3-RISERS 4-RISERS 5-RISERS 2-RISERS 37.31 40.54 40.58 40.58 41.25 40.09 40.58 40.58 39.80 39.41 39.32 38.85 40.54 40.54 38.80 41.25 41.25 37.29 37.21 41.15 41.25 39.03 40.41 41.25 40.99 41.09 (40.89) (40.29) (40.16) 2.3% 10.4% 8.3% 6:1 5:1 7:1 8:1 9:1 39.62 2.0% 5.0% 2.0% 2.3% 2.3% 4.9% 41.15 41.25 17.7% 9' UTILITY EASEMENT 40.59 40.17 39.61 39.90 40.04 39.45 39.41 39.11 40.17 39.03 36.72 36.72 37.66 36.99 37.14 37.14 DETENTION OUTFALL SEE SHEET C301 N:127177.22 E:188606.38 N:127149.29 E:188593.17 N:126964.67 E:188604.53 N:126964.51 E:188487.96 N:126974.98 E:188590.10 N:126976.58 E:188499.45 N:127062.74 E:188488.37 N:127069.63 E:188215.75 N:127080.94 E:188238.50 N:127182.65 E:188216.54 N:127161.56 E:188236.91 PROPOSED TRENCH DRAIN FFE=36.05 PROPOSED OUTLET STRUCTURE PROPOSED TRENCH DRAIN PROPOSED DRIVE WAY PER LCUASS 38.97 40.27 6-RISERS 39.79 42.99 41.68 41.68 41.77 39.79 39.79 40.44 41.38 42.50 43.05 40.52 39.94 39.24 39.30 36.17 36.97 37.07 36.47 40.64 35.14 36.09 36.53 36.97 41.09 40.67 39.69 39.52 (39.22) 41.09 41.09 40.02 40.02 40.75 (41.10) 40.69 40.20 40.11 40.08 40.00 1.9% 2.3% 0.9% 3.0% 3.7% 41.20 38.66 LEGEND: 5013 PROPOSED CONTOUR EXISTING CONTOUR PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. NOTES: 2.0% (47.45) EXISTING SPOT ELEVATION PROPOSED STORM PROPOSED VERTICAL CURB AND GUTTER CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C400 GRADING PLAN A. Reese B. Ruch 1"=20' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: Dec. 28, 2016 PROJECT: 1252-001 Sheet of 15 Sheets WEST PLUM HOUSING These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 12/28/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E N G I N E E R I N G N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com NORTH ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 W D D W F F W S F TF 9' UTILITY EASEMENT 5' UTILITY EASEMENT PLUM STREET (ROW VARIES) TOWN SQUARE CONDOMINIUMS THE LOFTS AT CAMPUS WEST OPEN BOTTOM DETENTION VAULT BASIN A1 STA 11+19.88 N: 127044.91 E: 188597.86 OUTLET STRUCTURE A2 STA 11+29.58 N: 127045.08 E: 188588.17 FES A STA 10+00.00 N: 127164.77 E: 188599.97 119.88 LF 12" PVC @ 0.50% 9.70 LF 12" PVC @ 1.80% EXISTING 12" PVC SANITARY SEWER EXISTING FH PROPOSED CONCRETE COLLAR & CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED WATER METER EXISTING 20" WATER LINE PROPOSED 4" WATER SERVICE PROPOSED 6" FIRE SERVICE PROPOSED ELECTRIC TRANSFORMER PROPOSED 8" SANITARY SERVICE N:127177.22 E:188606.38 N:126964.67 E:188604.53 N:126974.98 E:188590.10 N:127149.29 E:188593.17 PROPOSED TRENCH DRAIN TRENCH DRAIN CONNECTION SEE SHEET C300 5025 5030 5035 5040 5045 5050 5055 5025 5030 5035 5040 5045 5050 5055 9+75 10+00 11+00 11+50 119.88 LF 12" PVC @ 0.50% 9.70 LF 12" PVC @ 1.80% BASIN A1 STA 11+19.88 RIM 5037.8± INV. IN 5035.87 (W) INV. OUT 5035.87 (N) OUTLET STRUCTURE A2 STA 11+29.58 INV. 5036.05 (E) FES A STA 10+00.00 INV. 5035.27 (S) EXISTING GROUND PROPOSED GROUND NORTH ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C301 PLAN & PROFILE DETENTION OUTFALL A. Reese B. Ruch 1"=20' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: Dec. 28, 2016 PROJECT: 1252-001 Sheet of 15 Sheets WEST PLUM HOUSING These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 12/28/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E N G I N E E R I N G N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com EXISTING RIGHT OF WAY EXISTING WATER MAIN LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 3. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 5. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 6. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. W G T E EXISTING STORM SEWER PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED SEWER SERVICE S PROPOSED FIRE SERVICE F EXISTING SANITARY SEWER SS PROPOSED FIRE DEPT. CONN. PROPOSED CURB & GUTTER PROPOSED CURB STOP & METER PIT FDC PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D PROPERTY BOUNDARY EASEMENT LINE EXISTING FIBER OPTICS FO PROPOSED STORM SEWER PROPOSED WATER MAIN PROPOSED SANITARY SEWER W PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=20' DETENTION OUTFALL X G G G G FO FO FO VAULT ELEC S S H Y D WV WV VAULT ELEC CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR VAULT ELEC FO VAULT ELEC T FO E X X X X X X CTV CTV CTV CTV CTV FO FO FO FO FO FO FO FO E E E E E E E E E E E E E E E E E E E E E E CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV FO FO FO FO FO FO FO FO FO FO FO FO FO W W W W W W W W W W W W W W W W W W W W W W W W W W G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS S W W W W D D D SS SS S W S G G G G E E E E E E E E E E E E E E E E E E E E E UD UD UD UD UD UD F F F F F E E E E E E E E E E E E E E E F F F F F W F F W S F TF 9' UTILITY EASEMENT 9' UTILITY EASEMENT 5' UTILITY EASEMENT UTILITY EASEMENT 5' UTILITY EASEMENT PLUM STREET (ROW VARIES) THE LOFTS AT CAMPUS WEST TOWN SQUARE CONDOMINIUMS CITY PARK CONDOMINIUMS (BOOK 1291, PAGE 862) THE DISTRICT AT CAMPUS WEST (REC. NO. 20130032356) OPEN BOTTOM DETENTION VAULT UTILITY EASEMENT CONNECT TO EXISTING 20" WATER MAIN 20"x4" TAPPING SADDLE w/ 4" GV (S) N:127201.48 E:188591.27 CONNECT TO EXISTING 20" WATER MAIN 20"x6" TAPPING SADDLE w/ 6" GV (S) N:127201.57 CUT IN MANHOLE CONNECT TO E:188586.27 EXISTING 12" SANITARY SEWER N:127193.30 E:188559.04 SSMH A INV. IN=5026.72 (W) INV. IN=5027.05 (S) INV. OUT=5026.72 (E) FG=5035.84 8" SANITARY SERVICE INV. OUT=5027.37 (N) FG=5036.79 56.88 LF 12" PVC @ 0.28% 96.65 LF 12" PVC @ 0.28% 31.36 LF 8" PVC @ 1.00% PROPOSED ±42 LF 4" WATER SERVICE PROPOSED ±42 LF 6" FIRE SERVICE N:126964.51 E:188487.96 N:126964.67 E:188604.53 N:126974.98 E:188590.10 N:126976.58 E:188499.45 N:127177.22 E:188606.38 N:127149.29 E:188593.17 N:127074.31 E:188501.17 N:127080.94 E:188238.50 N:127161.56 E:188236.91 N:127182.65 E:188216.54 N:127069.63 E:188215.75 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING 20" WATER LINE EXISTING 12" PVC SANITARY SEWER EXISTING FH EXISTING FH PROPOSED CONCRETE COLLAR & CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 5' WALK w/ PAN PROPOSED 1' SIDEWALK CHASE PROPOSED 1' SIDEWALK CHASE PROPOSED 1' SIDEWALK CHASE PROPOSED 12" PVC STORM DRAIN PROPOSED ELECTRIC TRANSFORMER PROPOSED WATER METER EXISTING FH PROPOSED EXTERIOR STANDPIPE CONNECTION PROPOSED GAS/ ELECTRIC METERS EXMH RIM=5035.26 INV IN=5026.56 (W) INV IN=5026.93 (S) INV OUT=5026.51 (E) EXMH RIM=5036.72 INV IN=5027.06 (W) INV IN=5027.22 (N) INV OUT=5026.99(E) DETENTION OUTFALL SEE SHEET C301 EXISTING 20" WATER LINE EXISTING WATER SERVICE TO BE ABANDONED AT MAIN EXISTING WATER SERVICE TO BE ABANDONED AT MAIN EXISTING WATER SERVICE TO BE ABANDONED AT MAIN EXISTING WATER SERVICE TO BE ABANDONED AT MAIN APPROXIMATE LOCATION EXISTING WATER SERVICE TO BE ABANDONED AT MAIN APPROXIMATE LOCATION EXISTING WATER SERVICE TO BE ABANDONED AT MAIN EXISTING GAS LINE TO BE REMOVED EXISTING GAS LINE TO BE REMOVED EXISTING GAS LINE TO BE REMOVED EXISTING GAS LINE TO BE REMOVED TRENCH DRAIN CONNECTION INV. OUT=5038.31 (SE) FG=5039.03 DETENTION CONNECTION INV. IN=5036.05 (NW) FG=5036.05 75.26 LF 6" PVC @ 3.00% PROPOSED TRENCH DRAIN TRENCH BOTTOM SLOPE = 1% PROPOSED TRENCH DRAIN TRENCH BOTTOM SLOPE = 1% PROPOSED TRENCH DRAIN TRENCH BOTTOM SLOPE = 1% PROPOSED OUTLET STRUCTURE NORTH ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C300 UTILITY PLAN A. Reese B. Ruch 1"=20' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: Dec. 28, 2016 PROJECT: 1252-001 Sheet of 15 Sheets WEST PLUM HOUSING These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 12/28/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E N G I N E E R I N G N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OR FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 9. REFER TO PLUMBING PLANS FOR ALL WATER SERVICE AND SANITARY SEWER SERVICE LOCATIONS. IF CONFLICT OCCURS, BOTH THE PLUMBING ENGINEER AND CIVIL ENGINEER SHALL BE CONTACTED PRIOR TO INSTALLATION OR ORDERING OF MATERIALS. 10. ALL SANITARY SEWER SERVICE CONNECTION INVERTS AND LOCATIONS BASED ON BEST AVAILABLE DATA. CONTRACTOR TO VERIFY LOCATION PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER OF ANY DISCREPANCIES. 11. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 12. ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443/C877 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). STORM DRAINS SHOWN ON THIS DRAWING AS POLYVINYL CHLORIDE (PVC) SHALL BE C-900 OR APPROVED EQUAL. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND CITY SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 14. CONTRACTOR SHALL COORDINATE ANY NECESSARY TELEPHONE, CABLE, FIBER, GAS, AND ELECTRIC LOWERINGS (OR RE-ROUTING) WITH THE RESPECTIVE UTILITY PROVIDERS. 15. CONTRACTOR TO COORDINATE FINAL LOCATION OF ALL GAS AND ELECTRIC METERS WITH ARCHITECT AND UTILITY PROVIDERS. EXISTING WATER MAIN LEGEND: W G T CTV EXISTING STORM SEWER EXISTING CABLE EXISTING TELEPHONE EXISTING GAS PROPOSED SEWER SERVICE S EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED WATER SERVICE PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EASEMENT LINE PROPERTY BOUNDARY EXISTING LOTLINE W PROPOSED WATER MAIN PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED ELECTRIC TRANSFORMER PROPOSED ELECTRIC E EXISTING PAVEMENT TO BE REMOVED PROPOSED FIRE DEPARTMENT CONNECTION FDC TF PROPOSED FIRE SERVICE F EXISTING ELECTRIC E X X X X X PROPOSED 30" VERITCAL CURB & GUTTER THE LOFTS AT CAMPUS WEST TOWN SQUARE CONDOMINIUMS CITY PARK CONDOMINIUMS (BOOK 1291, PAGE 862) THE DISTRICT AT CAMPUS WEST (REC. NO. 20130032356) EXISTING 30" VERTICAL CURB & GUTTER TIE TO EXISTING SIDEWALK EXISTING PAVEMENT MARKINGS (TYP.) PROPOSED 5' WALK w/ PAN PROPOSED ACCESS RAMPS 5' UTILITY EASEMENT 44' - 40' - \A1;40' {\fISOCPEUR|b0|i0|c186|p34;}-{\fISOCPEUR|b0|i0|c186|p34;} PROPOSED SAWCUT LINE DETENTION VAULT OPEN BOTTOM UTILITY EASEMENT ASPHALT MILL LIMIT ASPHALT MILL LIMIT MATCH EXISTING N:127079.67 E:188201.29 TIE TO EXISTING CURB & GUTTER N:127163.49 E:188210.26 N:127182.65 E:188216.54 N:127069.63 E:188215.75 N:127062.74 E:188488.37 N:126964.51 E:188487.96 N:126964.67 E:188604.53 N:127177.22 E:188606.38 TIE TO EXISTING CUB & GUTTER N:127182.28 E:188611.47 PROPOSED ACCESS RAMPS R15' PROPOSED 2' CONCRETE CHASE PROPOSED 6' SIDEWALK PROPOSED 7' SIDEWALK PROPOSED 2' CONCRETE CHASE PROPOSED CONCRETE DRIVEWAY PROPOSED 2' CONCRETE CHASE PROPOSED 1' CONCRETE CHASE PROPOSED 1' CONCRETE CHASE PROPOSED 1' CONCRETE CHASE 5' CURB TRANSITION N:127182.86 E:188509.84 N:127181.98 E:188559.83 N:126974.98 E:188590.10 N:127149.29 N:127161.56 E:188593.17 E:188236.91 N:126976.58 E:188499.45 N:127080.94 E:188238.50 PLUM STREET (ROW VARIES) LINE TABLE LINE L1 L2 L3 L4 L5 L6 L8 LENGTH 5.14' 46.62' 15.05' 20.00' 14.95' 278.69' 6.45' BEARING S77°25'25.19"W N88°59'31.80"W N88°59'31.80"W N88°59'31.80"W N88°59'31.80"W N88°59'31.80"W S06°08'40.97"W CURVE TABLE CURVE C1 DELTA 84°51'47" RADIUS 20.00' LENGTH 29.62' BEARING S48°34'35"W CHORD 26.99' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C200 PAVING PLAN HORIZONTAL CONTROL & A. Reese B. Ruch 1"=20' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: Dec. 28, 2016 PROJECT: 1252-001 Sheet of 15 Sheets WEST PLUM HOUSING These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 12/28/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E N G I N E E R I N G N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com NORTH ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 1. SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS. 2. PAVEMENT MARKINGS SHALL BE PER CITY STANDARDS AND PROJECT SPECIFICATION MANUAL. 3. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 4. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 5. ALL PUBLIC CONCRETE SIDEWALKS SHALL BE 6" THICK. ALLEY DRIVEWAY/SIDEWALK CONCRETE SHALL BE 8" (MIN.) THICK. ACTUAL ALLEY CONCRETE THICKNESS SHALL BE BASED ON FINAL PAVEMENT DESIGN. 6. REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES. 7. DUE TO THE NUMBER OF PROPOSED STREET CUTS IN PLUM STREET, THE ENTIRE SOUTH HALF SHALL BE MILLED AND OVERLAID PRIOR TO PROJECT COMPLETION. PROPOSED VERTICAL CURB & GUTTER ACCESS RAMP w/ TRUNCATED DOMES EASEMENTS PUBLIC CONCRETE FLATWORK PROPERTY BOUNDARY PROPOSED LOT LINE PROPOSED EDGE OF PAVEMENT ASPHALT MILL & OVERLAY PRIVATE CONCRETE FLATWORK ASPHALT PATCH OHU SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W V AULT ELEC S T FO T FO ELEC VAULT ELEC W W ST / / / / / / / / / / / / / / / / / / / / / / / / FO X X X X X X X X X X X X X X G G G G FO FO FO W W W VAULT ELEC S S VAULT CABLE H Y D WV WV VAULT ELEC CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR VAULT ELEC FO G G G W E E G E VAULT ELEC T FO E E E CABLE W S O T T T T T T E E E X X X E E CTV CTV OHU OHU OHU OHU CTV X X X X X E E E T X CTV CTV CTV CTV CTV FO FO FO FO FO FO FO FO E E E E E E E E E X X X X E E E E E E E E E E E E E E E E E CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV FO FO FO FO FO FO FO FO FO FO FO FO FO W W W W W W W W W W W W W W W W W W W W W W W W W W G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS S W W W W D D D SS SS S W S G G G G E E E E E E E E E E E E E E E E E E E E E UD UD UD UD UD UD DS2 DS2 DS2 DS2 DS2 F F F F F E E E E E E E E E E E E E E E F F F F DS3 DS3 F / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / THE LOFTS AT CAMPUS WEST TOWN SQUARE CONDOMINIUMS CITY PARK CONDOMINIUMS (BOOK 1291, PAGE 862) THE DISTRICT AT CAMPUS WEST (REC. NO. 20130032356) / / / / / / / / / / / / / / EXISTING 20" WATER LINE EXISTING 12" PVC SANITARY SEWER EXISTING BUILDING TO BE REMOVED EXISTING BUILDING TO BE REMOVED EXISTING BUILDING TO BE REMOVED EXISTING BUILDING TO BE REMOVED EXISTING BUILDING TO BE REMOVED EXISTING BUILDING TO BE REMOVED EXISTING BUILDING TO BE REMOVED EXISTING BUILDING TO BE REMOVED EXISTING BUILDING TO BE REMOVED EXISTING TREE TO BE REMOVED (TYP.) EXISTING TREE TO BE REMOVED (TYP.) EXISTING GAS LINE TO BE REMOVED EXISTING GAS LINE TO BE REMOVED EXISTING GAS LINE TO BE REMOVED EXISTING GAS LINE TO BE REMOVED EXISTING UTILITIES TO BE REMOVED EXISTING UTILITIES TO BE REMOVED EXISTING UTILITIES TO BE REMOVED EXISTING UTILITIES TO BE REMOVED EXISTING UTILITIES TO BE REMOVED EXISTING GRAVEL DRIVE TO BE REMOVED EXISTING GRAVEL DRIVE TO BE REMOVED EXISTING GRAVEL DRIVE TO BE REMOVED EXISTING GRAVEL DRIVE TO BE REMOVED EXISTING GRAVEL DRIVE TO BE REMOVED EXISTING CURB AND GUTTER EXISTING 4' SIDEWALK TO BE REMOVED EXISTING 4' SIDEWALK TO BE REMOVED APPROXIMATE FULL DEPTH REMOVAL LIMIT APPROXIMATE FULL DEPTH REMOVAL LIMIT EXISTING CURB & GUTTER TO BE REMOVED PAVEMENT REMOVAL AREA PLUM STREET (ROW VARIES) CITY PARK AVENUE EXISTING TREE TO BE REMAIN EXISTING FENCE TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING WATER SPIGOT TO BE REMOVED ±40' - 44' - EXISTING FENCE TO BE REMOVED EXISTING FH EXISTING FH EXISTING CABLE VAULT TO BE RELOCATED EXISTING FH EXISTING LIGHT TO BE RELOCATED / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING WATER SERVICE TO BE ABANDONED AT MAIN EXISTING WATER SERVICE TO BE ABANDONED AT MAIN EXISTING WATER SERVICE TO BE ABANDONED AT MAIN EXISTING WATER SERVICE TO BE ABANDONED AT MAIN EXISTING EDGE OF ASPHALT EXISTING EDGE OF ASPHALT W W W W W W W W W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / APPROXIMATE LOCATION EXISTING WATER SERVICE TO BE ABANDONED AT MAIN APPROXIMATE LOCATION EXISTING WATER SERVICE TO BE ABANDONED AT MAIN / / / / / / / / / / / / / / / / / / / / / / / / / / / / / APPROXIMATE LOCATION EXISTING WATER SERVICE TO BE ABANDONED AT MAIN APPROXIMATE MILL LIMIT APPROXIMATE MILL LIMIT APPROXIMATE FULL DEPTH REMOVAL LIMIT APPROXIMATE MILL LIMIT PAVEMENT MILL AREA PAVEMENT MILL AREA N:127182.65 E:188216.54 N:127177.22 E:188606.38 N:126964.67 E:188604.53 N:126964.51 E:188487.96 N:127062.74 E:188488.37 N:127069.63 E:188215.75 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C100 & DEMOLITION PLAN EXISTING CONDITIONS A. Reese B. Ruch 1"=20' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: Dec. 28, 2016 PROJECT: 1252-001 Sheet of 15 Sheets WEST PLUM HOUSING These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 12/28/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E N G I N E E R I N G N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com NORTH LEGEND: EXISTING STORM SEWER EXISTING VALVE EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) FIELD SURVEY BY: EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROPERTY BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR 5015 5013 H Y EXISTING TREES (TO BE REMOVED) EXISTING PAVEMENT TO BE MILLED AND OVERLAID 1. ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9. ALL TREE REMOVAL SHOWN SHALL BE COMPLETED OUTSIDE OF THE SONGBIRD NESTING SEASON (FEB 1 - JULY 31) OR CONDUCT A SURVEY OF TREES ENSURING NO ACTIVE NESTS IN THE AREA. 10. REFER TO LANDSCAPE AND IRRIGATION PLANS FOR ADDITIONAL TREE PROTECTION MEASURES. TREE PROTECTION NOTES: SUBSURFACE EXPLORATION BY: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249. 4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 7. ADDITIONAL TREES NOT SHOWN ON THESE PLANS MAY EXIST AND MAY REQUIRE REMOVAL. COORDINATION OF WHICH TREES ARE TO REMAIN AND WHICH ARE TO BE REMOVED SHOULD BE COORDINATED WITH THE CITY FORESTER. REFER TO LANDSCAPE PLANS AND TREE MITIGATION PLAN FOR ADDITIONAL INFORMATION. 8. CONTRACTOR SHALL COORDINATE WITH FORT COLLINS UTILITY FIELD OPERATIONS DEPARTMENT AT (970) 221-6700 FOR WATER AND SEWER SERVICE ABANDONMENT. TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 VAULT ELEC ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 NORTHERN ENGINEERING PROJECT NO. 1252-001 DATE: JUNE 2016 TERRACON CONSULTANTS, INC. GEOTECHNICAL ENGINEERING REPORT PLUM STREET PROJECT 1303 AND 1307 WEST PLUM STREET FORT COLLINS, COLORADO TERRACON PROJECT NO. 20165035 DATE: MAY 19, 2016 EXISTING PAVEMENT TO BE REMOVED T WV W sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the Final Drainage Report for West Plum Housing, dated December 28, 2016 by Northern Engineering shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by th e construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by City of Fort Collins. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: PROJECT DATUM: NAVD88 City of Fort Collins Benchmark 19-97 At the Southeast corner of West Elizabeth and Shields St., on a concrete traffic signal base. ELEV.=5025.74 City of Fort Collins Benchmark 3-08 Southwest corner of Mulberry St. and Shields St. on a concrete traffic signal base. ELEV.=5030.29 Please Note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted for their vertical datums. If NGVD29 Unadjusted Datum is required for any purpose, the following equation should be used: NGVD29 Unadjusted = NAVD88 - 3.17' Basis of Bearings The Basis of Bearings is the South line of the Northeast Quarter of Section 15, as bearing South 89°04'20" East. 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 48. Approved Variances are listed as follows: a. Driveway Spacing CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. 16. For additional information see separate Stormwater Management Plan / Erosion Control Report for West Plum Housing. B. Street Improvement Notes 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. All recommendations of the Final Drainage Report for West Plum Housing, dated December 28, 2016 by Northern Engineering shall be followed and implemented. 3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Utility Notes 1. All waterline and sanitary sewer construction shall conform to the City of Fort Collins Utility standards and specifications current to date of construction. 2. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water utility. 3. Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire. 4. HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections. Tracer wire shall be installed with the HDPE service, and shall extend up the curb stop. The curb stop shall be covered with a metal valve box and "water" lid per City Water Detail 11A. C002 GENERAL & CONSTRUCTION NOTES A. Reese B. Ruch NTS No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: Dec. 28, 2016 PROJECT: 1252-001 Sheet of 15 Sheets WEST PLUM HOUSING These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 12/28/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E N G I N E E R I N G N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: Dec. 28, 2016 PROJECT: 1252-001 Sheet of 15 Sheets WEST PLUM HOUSING These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 12/28/16 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E N G I N E E R I N G N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com DECEMBER 2016 I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: VICINITY MAP NORTH 1"=1500' PROJECT DATUM: NAVD88 City of Fort Collins Benchmark 19-97 At the Southeast corner of West Elizabeth and Shields St., on a concrete traffic signal base. ELEV.= 5025.74 City of Fort Collins Benchmark 3-08 Southwest corner of Mulberry St. and Shields St. on a concrete traffic signal base. ELEV.= 5030.29 Please Note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted for their vertical datums. If NGVD29 Unadjusted Datum is required for any purpose, the following equation should be used: NGVD29 Unadjusted = NAVD88 - 3.17' Basis of Bearings The Basis of Bearings is the South line of the Northeast Quarter of Section 15, as bearing South 89°04'20" East. Northern Engineering Project No. 1252-001 Date: June 2016 ORIGINAL FIELD SURVEY BY: PROJECT BENCHMARKS: CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R A TRACT OF LAND LOCATED IN THE NORTHEAST QUARTER OF SECTION 15, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO OWNER/APPLICANT PROJECT TEAM: SITE ENGINEER Northern Engineering Services, Inc. Nick Haws, PE, LEED AP 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 SURVEYOR ARCHITECT CONTACT INFORMATION PROJECT TEAM: SHEET INDEX E N G I N E E R I N G N O R T H E RN FINAL UTILITY PLANS FOR City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER GAS----------------- Xcel Energy----------------------------- Pat Kreager (970) 225-7840 ELECTRIC-------- City of Fort Collins Light & Power-- Luke Unruh (970) 416-2724 CABLE------------- Comcast---------------------------------- Don Kapperman (970) 567-0425 TELECOM.--------CenturyLink------------------------------- William Johnson (970) 377-6401 WATER------------ City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339 WASTEWATER--City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339 STORMWATER- City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339 LANDSCAPE ARCHITECT GEOTECH PROJECT LOCATION WEST PLUM HOUSING Humphreys & Partners Architects, L.P. Yaohua Yu 5339 Alpha Road, Suite 300 Dallas, Texas 75240 (972) 701-9636 Ripley Design, Inc. Stephanie Van Dyken, PLA, APA 419 Canyon Avenue, Suite 200 Fort Collins, Colorado 80513 (970) 224-5828 Northern Engineering Services, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 E N G I N E E R I N G N O R T H E RN Terracon Consultants, Inc. Kurt A. Stauder, P.G. 1901 Sharp Point Drive, Suite C Fort Collins, CO 80525 (970) 484-0359 C001 COVER SHEET A. Reese B. Ruch NTS C001 COVER SHEET Terracon Consultants, Inc. Geotechnical Engineering Report Plum Street Project 1303 and 1307 West Plum Street Fort Collins, Colorado Terracon Project No. 20165035 Date: May 19, 2016 SUBSURFACE EXPLORATION BY: C002 GENERAL & CONSTRUCTION NOTES S. SHIELDS ST. W. MULBERRY ST. W. ELIZABETH ST. CSU W. PLUM ST. W. LAUREL ST. CITY PARK AVE. ■ land planning ■ landscape architecture ■ ■ urban design ■ entitlement ■ C100 EXISTING CONDITIONS & DEMOLITION PLAN C200 HORIZONTAL CONTROL & PAVING PLAN C300 UTILITY PLAN C400 GRADING PLAN C600-C601 UTILITY DETAILS Plum Owner Ft Collins CO LLC 999 South Shady Grove Road, Suite 600 Memphis, TN 38120 (901) 259-2500 C602 STORMWATER DETAILS TYPICAL SECTIONS C301 DETENTION OUTFALL PLAN & PROFILE C603 SITE DETAILS C700 EROSION CONTROL PLAN C701 EROSION CONTROL DETAILS C800 DRAINAGE EXHIBIT C500 WEST PLUM STREET PLAN & PROFILE