Loading...
HomeMy WebLinkAboutKING SOOPERS #146, MIDTOWN GARDENS MARKETPLACE (FORMERLY KMART REDEVELOPMENT ) - PDP - PDP160043 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANS# 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 O www.gallowayUS.com C 2016. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By: H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_01-Covr.dwg - Rob Gordon - 2015-04-16 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT King Soopers Marketplace 65 Tejon Street Denver, CO 80223 Phone (303) 778-3053 Fax (303) 871-9262 KSS000146 UTILITY PLANS FOR LOTS 1, 2, AND 4, OF K-MART PLAZA, AND ALL OF LOT 2 OF THE EXTENSION OF K-MART PLAZA, SITUATED IN THE SE 1/4 OF SECTION 23, T. 7 N., R. 69 W., OF THE 6TH P.M. CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO DECEMBER 2016 MIDTOWN GARDENS MARKETPLACE SITE VICINITY MAP NOT TO SCALE LANDSCAPE ARCHITECT SURVEYOR ARCHITECT DEVELOPER/APPLICANT GEOTECHNICAL ENGINEER GALLOWAY & COMPANY, INC. 3760 E. 15th STREET, SUITE 202 LOVELAND, COLORADO 80538 TEL: (970) 800-3300 FAX: (303) 770-3636 ATTN: RON RENNKE KUMAR & ASSOCIATES 2390 S. LIPAN ST. DENVER, COLORADO 80223 TEL: (303) 742-9700 FAX: (303) 742-9666 KING SOOPERS INC. 65 TEJON STREET DENVER, CO 80223 TEL: (303) 778-3150 CONTACT: KEVIN McKENZIE GALLOWAY & COMPANY, INC. 6162 S. WILLOW DRIVE, SUITE 320 GREENWOOD VILLAGE, COLORADO 80111 TEL: (303) 770-8884 # 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 O www.gallowayUS.com C 2016. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By: H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_02-Notes.dwg - Rob Gordon - 2015-04-16 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT King Soopers Marketplace 65 Tejon Street Denver, CO 80223 Phone (303) 778-3053 Fax (303) 871-9262 KSS000146 RDG PJD NOVEMBER 2016 GENERAL AND CONSTRUCTION NOTES 2 A. GENERAL NOTES 1. All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. LOT 1 487,410 SF (11.189 AC) W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W C O CO E UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE SS SS SS SS SS SS SS SS S 1 RxDRIVE THRU GROCERY PICK UP 2 3 4 MARKETPLACE 119,000 SF LOT 1 487,410 SF (11.189 AC) C O CO E X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X E IR IR IR EVT ECB GM E E E E TL TL TV RI SS SD SD E ECB EM E TL SS GM IR TL EXISTING BUILDING TO REMAIN ONE STORY BUILDING ONE STORY BUILDING 1 RxDRIVE THRU GROCERY PICK UP 2 3 4 MARKETPLACE 119,000 SF N1°13'28"E 64.73' S89°28'09"E 657.55' L11 ǻ=22°01'36" R=30.00' L=11.53' CB=S11°28'34"W C=11.46 S0°21'19"W 140.00' S0°49'49"W 66.21' S2°41'09"W 146.80' S0°14'46"W 18.91' S2°20'50"W 192.27' C1 S19°21'41"E 15.80' C2 N89°27'51"W 146.92' S0°22'28"W 160.00' N89°27'52"W 227.71' L12 C3 N89°20'48"W 60.46' C4 L13 C5 N89°27'52"W 66.64' N1°41'18"E 29.21' N88°54'47"W 7.28' N1°22'06"E 173.39' N88°39'54"W 19.64' N1°13'28"E 34.87' C6 N27°53'31"W 41.25' N1°22'03"E 424.81' S89°37'41"E 2.03' LOT 1 487,410 SF (11.189 AC) C O CO E UT UT UT UT X X X DRAKE ROAD 100' RIGHT OF WAY 29.8' R10' R2.5' 12.7' 9.4' 10.2' 14' 12' 13.6' 39.5' 66.8' 10' R5' R10' PROPOSED SIDEWALK; REFERENCE SITE DETAILS, SHEET 8 PROPOSED CURB AND GUTTER; REFERENCE SITE DETAILS, SHEET 8 PROPOSED WHITE TRAFFIC SYMBOLS; REFERENCE SITE DETAILS, SHEET 8 PROPOSED 2' SOLID WHITE STROP BAR; REFERENCE SITE DETAILS, SHEET 8 EXISTING CURB, GUTTER AND SIDEWALK; REFERENCE SITE DETAILS, SHEET 8 EXISTING CONCRETE PAN TO REMAIN EXISTING CONCRETE PAN TO REMAIN 61.7' 50' 62.8' 5.7' 7.5' 10' PROPOSED BUS PULL OUT 6.5' 11.7' 8.3' 5.6' N:444470.76 E:116877.07 ELEV: 5026.42 N:444470.69 E:116882.66 ELEV: 5026.30 N:444468.88 E:117057.24 ELEV: 5023.37 N:444468.80 E:117063.68 ELEV: 5023.34 4" SOLID WHITE LANE LINE 4" DOUBLE YELLOW LANE LINE SAWCUT LINE A A N:445036.40 E:117462.83 ELEV: 5017.60 N:445119.50 E:117463.94 ELEV: 5017.28 N:445038.77 1 RxDRIVE THRU GROCERY PICK UP 2 3 4 MARKETPLACE 119,000 SF LOT 1 487,410 SF (11.189 AC) UT UT UT UT X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X G G G UT UT UT E LOT 1 K-MART PLAZA LOT 2 EXTENTION OF K-MART PLAZA LOT 4 K-MART PLAZA LOT 2 K-MART PLAZA E E E E E EXISTING BUILDING TO REMAIN ONE STORY BUILDING ONE STORY BUILDING TO REMAIN DRAKE ROAD 100' RIGHT OF WAY # 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 O www.gallowayUS.com C 2016. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By: H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_08-Details.dwg - Rob Gordon - 2015-04-16 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT King Soopers Marketplace 65 Tejon Street Denver, CO 80223 Phone (303) 778-3053 Fax (303) 871-9262 KSS000146 RDG PJD NOVEMBER 2016 SITE DETAILS 8 CITY ENGINEER DATE DATE DATE DATE DATE STORMWATER UTILITY PARKS & RECREATION TRAFFIC ENGINEER DATE APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: WATER & WASTEWATER UTILITY CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL ENVIRONMENTAL PLANNER NOT TO SCALE NOT TO SCALE 'PARKING ONLY' SIGN DETAIL NOT TO SCALE 'VAN ACCESSIBLE' SIGN DETAIL NOT TO SCALE HANDICAPPED SYMBOL NOT TO SCALE 6 R3-7R SIGN DETAIL NOT TO SCALE K-1833 SIGN DETAIL NOT TO SCALE LANE STRIPING DETAILS NOT TO SCALE 8' CROSS PAN DETAIL NOT TO SCALE BICYCLE RACK DETAIL NOT TO SCALE ADA HANDICAP RAMP DETAIL NOT TO SCALE 16 CONCRETE SIDEWALK DETAIL(PRIVATE) NOT TO SCALE STOP SIGN DETAIL NOT TO SCALE HANDICAP PARKING SIGN NOT TO SCALE NOT TO SCALE SERVICE MARKER NOT TO SCALE 1 2 3 4 5 7 8 9 10 11 17 18 19 20 TOTAL SIGN AREA PER FACE 48 SF 11'-6 1/2" 8'-0" 4'-0" 3'-0" 4'-9" SMOOTH FACE CMU TO MATCH ADJACENT KING SOOPERS GROCERY STORE CAST STONE SILL - TO MATCH SIMILAR MATERIALS ON ADJACENT KING SOOPERS GROCERY STORE GROUND FACE CMU BASE TO MATCH ADJACENT KING SOOPERS GROCERY STORE CAST STONE SILL - TO MATCH SIMILAR MATERIALS ON ADJACENT KING SOOPERS GROCERY STORE BLACK CABINET, INTERNALLY ILLUMINATED MONUMENT SIGN 1'-3" 2'-9" 2'-9" 2'-41 2" # 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 O www.gallowayUS.com C 2016. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By: H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_09-Details.dwg - Rob Gordon - 2015-04-16 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT King Soopers Marketplace 65 Tejon Street Denver, CO 80223 Phone (303) 778-3053 Fax (303) 871-9262 KSS000146 RDG PJD NOVEMBER 2016 SITE DETAILS 9 NOT USED SCALE: MONUMENT SIGN DETAILS NOT TO SCALE NOT USED SCALE: SCALE: 1"=10' NOT USED SCALE: NOT USED SCALE: NOT USED SCALE: 16 NOT USED SCALE: NOT USED SCALE: NOT USED SCALE: NOT USED SCALE: 5 CO CO E 12''STM 12''STM 12''STM 15''STM 15''STM 15''STM 15'' STM 15''STM 15''STM 12''STM 24''STM 24''STM 24''STM 24''STM 24''STM 24''STM 1 5''STM 15''STM 15''STM 15''STM 15''STM 24''STM 24''STM 24''STM 12''STM 18''S TM 18''STM 18''STM E IR IR IR EVT ECB GM E E E E TL TL TV RI WV SS WV WV SD SD E ECB EM E TL SS GM WM IR TL DRAKE ROAD 100' RIGHT OF WAY S. COLLEGE AVE. R.O.W. WIDTH VARIES SD 12''STM 12''STM 18''STM 18''STM 18''STM 18''STM S D WV SS W WV W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W C O CO E UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE SS SS SS SS SS SS SS SS SS SS SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS CO CO E 12''STM 12''STM 12''STM 15''STM 15''STM 15''STM 15'' STM 15''STM 15''STM 12''STM 24''STM 24''STM 24''STM 24''STM 24''STM 24''STM 12 ''STM 15''STM 15''STM 15''STM 15''STM 15''STM 24''STM 24''STM 24''STM 12''STM 18 ''STM 18''STM 18''STM E IR IR IR EVT ECB GM E E E E TL TL TV RI WV SS WV WV SD SD E ECB EM E TL SS GM WM IR TL DRAKE ROAD 100' RIGHT OF WAY S. COLLEGE AVE. R.O.W. WIDTH VARIES SD 12''STM 12''STM 18''STM 18''STM 18''STM 18''STM S D WV SS W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W C O CO E UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE 12''STM 12''STM 12''STM 15''STM 15'' STM 15''STM 15''STM 15''STM 15''STM 12''STM 24''STM 24''STM 24''STM 24''ST M 24''STM 24''STM 15''STM 15''STM 15''STM 15''STM 15''STM 24''STM 24''STM 24''STM 12''STM 18''STM 18''STM 18''STM UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT G G G G G G G G G UT UT UT UT UT UT UT UT G G G G G G G G G G G G G G G G G G G G G G G E IR IR IR EVT ECB GM E E E E TL TL TV RI WV SS WV WV SD SD E ECB EM E TL SS GM WM IR TL DRAKE ROAD 100' RIGHT OF WAY S. COLLEGE AVE. R.O.W. WIDTH VARIES SD 12''STM 18''STM 18''STM 18''STM 18''STM SS SS SS S D SS SS UE UE UE WV W WV W SD WV WV WV SS MARKETPLACE 119,000 SF STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM W STM STM STM STM STM STM STM STM STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 8''SS 8''SS 8 ''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8'' SS 8''SS 8''SS 8''SS 8''SS LOT 1 487,410 SF (11.189 AC) 1 3 3 3 4 4 4 4 5 5 5 5 5 5 4 5 5 6 6 7 7 6 9 7 7 7 7 7 7 7 7 7 7 8 8 8 8 3 3 9 9 9 9 9 9 9 9 9 9 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 12 12 12 12 12 13 13 14 15 15 16 16 17 17 17 19 18 20 22 21 21 21 21 22 22 22 22 24 24 24 24 16 24 24 24 24 24 24 25 25 25 25 25 27 27 27 27 30 29 29 29 29 29 29 29 29 29 12 32 32 32 32 32 32 34 33 34 32 35 35 35 35 35 35 35 35 35 36 36 36 36 37 36 36 38 39 39 39 40 5 5 9 9 9 9 22 22 41 41 41 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 34 34 33 # 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 O www.gallowayUS.com C 2016. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By: H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_13-Util.dwg - Rob Gordon - 2015-04-16 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT King Soopers Marketplace 65 Tejon Street Denver, CO 80223 Phone (303) 778-3053 Fax (303) 871-9262 KSS000146 RDG PJD NOVEMBER 2016 OVERALL UTILITY PLAN 13 SCHEDULE LEGEND PROPERTY BOUNDARY LINE ADJACENT PROPERTY BOUNDARY LINE EXISTING TO REMAIN EASEMENT BOUNDARY LINE EXISTING TO BE REMOVED SAWCUT LINE PROPOSED WATER LINE PROPOSED GAS LINE PROPOSED OVERHEAD ELECTRICAL PROPOSED UNDERGROUND ELECTRICAL PROPOSED SANITARY SEWER OHE UE UG W SS UTTELEPHONE PROPOSED UNDERGROUND STM PROPOSED STORM SEWER FO PROPOSED FIBER OPTIC LINE EXISTING STORM SEWER EXISTING SANITARY SEWER MANHOLE EXISTING GAS METER EXISTING ELECTRICAL MANHOLE EXISTING WATER VALVE EXISTING FENCE EXISTING TRAIN TRACTS EXISTING FIRE HYDRANT EXISTING ELECTRICAL BOX X X X X EXISTING ELECTRICAL METER/RISER EXISTING WATER METER EXISTING LIGHT POLE EXISTING TELEPHONE MANHOLE EXISTING TELEPHONE RISER EXISTING IRRIGATION BOX EM SECTION LINE WV WM SS CO D Y H IR ECB TL E EVT GM RI E EXISTING SANITARY SEWER CLEANOUT EXISTING ELECTRICAL CABINET EXISTING ELECTRICAL VAULT EXISTING STORM SEWER INLET STM EXISTING WATER LINE EXISTING GAS LINE EXISTING OVERHEAD ELECTRICAL EXISTING UNDERGROUND ELECTRICAL EXISTING SANITARY SEWER OHE UE UG W SS UTTELEPHONE EXISTING UNDERGROUND STM PROPOSED STORM SEWER (LESS THAN 12") FO EXISTING FIBER OPTIC LINE STM EXISTING STORM SEWER (LESS THAN 12") CITY ENGINEER DATE DATE DATE DATE DATE STORMWATER UTILITY PARKS & RECREATION TRAFFIC ENGINEER DATE APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: WATER & WASTEWATER UTILITY CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL ENVIRONMENTAL PLANNER SCALE: 1"=50' 0 10 20 50 PROPOSED 119,000 S.F. KING SOOPERS STORE PROPOSED MONUMENT SIGN PROPOSED CURB INLET PROPOSED AREA INLET PROPOSED STORM SEWER (SIZE AS NOTED) EXISTING STORM SEWER TO REMAIN EXISTING SANITARY SEWER TO REMAIN PROPOSED GREASE INTERCEPTOR AND SAMPLING MANHOLE PROPOSED SANITARY SEWER MANHOLE (4'Ø) PROPOSED DOMESTIC WATER SERVICE PROPOSED 3" WATER METER EXISTING GATE VALVE TO REMAIN PROPOSED GAS SERVICE EXISTING GAS LINE TO REMAIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 PROPOSED SITE LIGHT; REFER TO PHOTOMETRIC PLAN EXISTING STREET LIGHT TO REMAIN PROPOSED 6" FIRE LINE EXISTING INLET TO REMAIN PROPOSED STORM MANHOLE (4'Ø) (PRIVATE) EXISTING STORM MANHOLE TO REMAIN PROPOSED SANITARY SEWER (SIZE AS NOTED) EXISTING SANITARY SEWER MANHOLE TO REMAIN PROPOSED 8" C900 PVC WATER MAIN EXISTING 8" WATER LINE TO REMAIN PROPOSED FIRE HYDRANT ASSEMBLY WITH 6-INCH GATE VALVE AND LINE PROPOSED GATE VALVE PROPOSED FIRE DEPARTMENT CONNECTION LOCATION EASEMENT SCHEDULE BASIS OF BEARING THE EAST LINE OF THE SOUTHEAST QUARTER OF SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PM. BEING MONUMENTED AT THE NORTH END BY A 2-1/2" ALUMINUM CAP, AND AT THE SOUTH END BY A 3" ALUMINUM CAP, IS ASSUMED TO BEAR N 00°18'00" W, WITH A DISTANCE OF 2640.61 FEET BETWEEN SAID MONUMENTS. BENCHMARK NATIONAL GEODETIC SURVEY BENCHMARK "C322 RESET 1959" NAVD 88 ELEVATION: 4989.40 A STANDARD 3 1/2 INCH U.S. CONSTRUCTION AND GEODETIC SURVEY BRASS BENCHMARK DISK SET IN THE TOP OF A CONCRETE WALL ON THE NORTH SIDE OF SPRING CREEK. LOCATED 47 FEET WEST OF THE CENTERLINE OF COLLEGE AVENUE (AKA U.S. HIGHWAY 287) AND 3,566 FEET NORTH OF THE CENTERLINE OF DRAKE STREET. CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. PROPOSED UNDERGROUND ELECTRICAL PROPOSED ELECTRICAL TRANSFORMER PROPOSED UNDERGROUND TELEPHONE CONDUIT EXISTING UNDERGROUND TELEPHONE LINE TO REMAIN EXISTING AREA INLET TO BE REPLACED WITH PROPOSED MANHOLE PROPOSED STORM SEWER INLET PROPOSED MANHOLE PROPOSED WATER VALVE PROPOSED FIRE HYDRANT PROPOSED RAIN GARDEN STORM SEWER (PRIVATE) EXISTING UNDERGROUND ELECTRICAL TO REMAIN EXISTING ELECTRICAL BOX/METER/CABINET/OR VAULT TO REMAIN EXISTING TELEPHONE RISER/MANHOLE TO REMAIN EXISTING WATER METER TO REMAIN EXISTING GAS METER TO REMAIN EXISTING IRRIGATION BOX TO REMAIN 40 EXISTING CABLE BOX TO REMAIN 41 PROPOSED BUILDING ROOF DRAINS EXISTING 6' UTILITY EASEMENT; REF. PLAT EXISTING 15' UTILITY EASEMENT; REF. PLAT EXISTING 20' UTILITY EASEMENT; REF. PLAT EXISTING 40' UTILITY EASEMENT; REF. PLAT EXISTING 10' DRAINAGE EASEMENT; REF. PLAT EXISTING TRAFFIC EASEMENT TO BE VACATED; REF. PLAT EXISTING SHARED PARKING EASEMENT; REF. PLAT EXISTING 40' UNDERGROUND UTILITY EASEMENT; REF. PLAT PROPOSED 20' WATER EASEMENT; REF. PLAT PROPOSED UTILITY EASEMENT; REF. PLAT PROPOSED TRAFFIC EASEMENT; REF. PLAT EXISTING 6' GAS AND POWER EASEMENT; REF. PLAT WV WV SS 1 RxDRIVE THRU GROCERY PICK UP 2 3 4 MARKETPLACE 119,000 SF STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM LOT 1 487,410 SF (11.189 AC) IP IP IP IP IP IP IP IP IP IP IP IP IP IP SSA CWA PT SP SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF # 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 O www.gallowayUS.com C 2016. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By: H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_12-Eros.dwg - Rob Gordon - 2015-04-16 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT King Soopers Marketplace 65 Tejon Street Denver, CO 80223 Phone (303) 778-3053 Fax (303) 871-9262 KSS000146 RDG PJD NOVEMBER 2016 EROSION CONTROL PLAN 12 SCALE: 1"=50' 0 10 20 50 BASIS OF BEARING THE EAST LINE OF THE SOUTHEAST QUARTER OF SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PM. BEING MONUMENTED AT THE NORTH END BY A 2-1/2" ALUMINUM CAP, AND AT THE SOUTH END BY A 3" ALUMINUM CAP, IS ASSUMED TO BEAR N 00°18'00" W, WITH A DISTANCE OF 2640.61 FEET BETWEEN SAID MONUMENTS. BENCHMARK NATIONAL GEODETIC SURVEY BENCHMARK "C322 RESET 1959" NAVD 88 ELEVATION: 4989.40 A STANDARD 3 1/2 INCH U.S. CONSTRUCTION AND GEODETIC SURVEY BRASS BENCHMARK DISK SET IN THE TOP OF A CONCRETE WALL ON THE NORTH SIDE OF SPRING CREEK. LOCATED 47 FEET WEST OF THE CENTERLINE OF COLLEGE AVENUE (AKA U.S. HIGHWAY 287) AND 3,566 FEET NORTH OF THE CENTERLINE OF DRAKE STREET. CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. CITY ENGINEER DATE DATE DATE DATE DATE STORMWATER UTILITY PARKS & RECREATION TRAFFIC ENGINEER DATE APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: WATER & WASTEWATER UTILITY CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL ENVIRONMENTAL PLANNER EROSION CONTROL LEGEND SILT FENCE EXISTING STORM SEWER EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM SEWER (12" AND LARGER) INLET GRAVEL FILTER VEHICLE TRACKING CONTROL CONSTRUCTION ENTRANCE GRAVEL SOCK INLET PROTECTION CONCRETE WASHOUT AREA GRAVEL SOCK IN GUTTER SURFACE ROUGHENING LIMITS OF CONSTRUCTION FLOW ARROW VTC SF IP GS SB CWA SR CONTRACTOR STAGING AREA (APPROXIMATE) SCL SEDIMENT CONTROL LOG SSA (SEEDING BY OTHERS) PTTOILET PORTABLE SP SITE POSTING (CONTACTS AND PERMITS) PROPOSED STORM SEWER (LESS THAN 12") EXISTING CONTOUR PROPOSED CONTOUR 12' 'STM 12''STM 12''STM 15''STM 15''STM 15''STM 15''STM 15' 'STM 15''STM 12''STM 24''STM 24''STM 24''STM 24''STM 24''STM 24''STM 12''STM 15' 'STM 15''STM 15''STM 15''STM 15''STM 24''STM 24''STM 24''STM 18''STM 18'' STM 18''STM UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT G G G G G G G G G UT UT UT UT UT UT UT UT G G G G G G G UT UT UT UT G G G G G G G X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X G X X G G G G G G G G G G G UT UT UT X X X X X X X X X X X X X X X X X X X X X X SS E IR IR IR EVT ECB GM IR CO N0°22'28"E 2640.62' BASIS OF BEARINGS IR E E E E TL TL TV RI WV SS SD CO EM SS WM WV GM D Y H D Y H SD E IR WECB GM ECB D Y H WV D Y H WV ECB EM E TL SS GM WM IR CO TL CO SS EXISTING BUILDING TO REMAIN ONE STORY BUILDING ONE STORY BUILDING TO REMAIN DRAKE ROAD 100' RIGHT OF WAY S. COLLEGE AVE. R.O.W. WIDTH VARIES SD 18''STM 18''STM 18''STM 18''STM SS SS S D CO SS SS SS SS SS SS SS UE UE UE UE UE UE WV W SD WV WV WV SS 1 RxDRIVE THRU GROCERY PICK UP 2 3 4 MARKETPLACE 119,000 SF STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM W STM STM STM STM STM STM STM STM STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 8''SS 8'' SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8' 'SS 8''SS 8''SS 8''SS 8''SS LOT 1 487,410 SF (11.189 AC) SINGLE TYPE 13 COMBINATION INLET A-10 0.67 0.90 1.00 OS-1 0.15 0.85 1.00 A-1 0.63 0.85 1.00 A-2 0.26 0.86 1.00 A-3 0.19 0.91 1.00 A-4 0.75 0.90 1.00 A-6 0.30 0.78 0.97 A-8 0.37 0.81 1.00 A-7 0.92 0.90 1.00 A-9 0.42 0.90 1.00 A-11 0.11 0.95 1.00 A-12 0.32 0.74 0.92 A-13 0.45 0.87 1.00 B-1 1.11 0.88 1.00 B-2 1.31 0.89 1.00 E-1 0.15 0.85 1.00 D-1 0.66 0.65 0.82 B-3 1.38 0.87 1.00 C-1 0.74 0.92 1.00 C-2 0.29 0.92 1.00 SINGLE TYPE 13 COMBINATION INLET 5' TYPE R INLET 5' TYPE R INLET 5' TYPE R INLET 5' TYPE R INLET 5' TYPE R INLET 5' TYPE R INLET 5' TYPE R INLET 5' TYPE R INLET TYPE 13 AREA INLET TYPE 13 AREA INLET TYPE 13 AREA INLET EXISTING INLET TO BE REMOVED EXISTING INLET TO BE REMOVED EXISTING INLET TO BE REMOVED EXISTING INLET TO BE REMOVED EXISTING INLET TO BE REMOVED & REPLACED W/ 4' MANHOLE EXISTING INLET TO BE REMOVED & REPLACED W/ 4' MANHOLE EXISTING INLET TO BE REMOVED & REPLACED W/ 4' MANHOLE # 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 O www.gallowayUS.com C 2016. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By: H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_11-Drainage.dwg - Phil Dalrymple - 2015-04-16 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT King Soopers Marketplace 65 Tejon Street Denver, CO 80223 Phone (303) 778-3053 Fax (303) 871-9262 KSS000146 SITE LEGEND ADJACENT PROPERTY BOUNDARY LINE PROPERTY BOUNDARY LINE PROPOSED CURB & GUTTER EXISTING CURB & GUTTER TO REMAIN PROPOSED INLET EASEMENT BOUNDARY LINE STREET LIGHT EXISTING TO BE REMOVED GRADING LEGEND EXISTING STORM SEWER PROPOSED STORM SEWER STS 45 PROPOSED CONTOUR 5245 EXISTING CONTOUR STS STS PROPOSED STORM SEWER (LESS THAN 12") DRAINAGE LEGEND PROPOSED BASIN BOUNDARY LINE DESIGN POINT BASIN AREA IN ACRES 100-YEAR RUNOFF COEFFICIENT BASIN DESIGNATION A 2-YEAR RUNOFF COEFFICIENT 0.00 0.00 0.00 FLOW ARROW CITY OF FORT COLLINS DRAINAGE NOTES 1. ALL STREET, SANITARY SEWER, STORM SEWER AND WATER CONSTRUCTION SHALL CONFORM TO CITY STANDARDS AND SPECIFICATIONS CURRENT AT THE DATE OF EXECUTION OF THE DEVELOPMENT AGREEMENT PERTAINING TO THIS DEVELOPMENT. ANY CONSTRUCTION OCCURRING THREE YEARS AFTER THE EXECUTION OF THE DEVELOPMENT AGREEMENT SHALL REQUIRE RE-EXAMINATION OF THE PLANS BY THE DIRECTOR WHO MAY REQUIRE THAT THEY BE MADE TO CONFORM TO STANDARDS AND SPECIFICATIONS CURRENT AT THAT TIME. 2. THE TYPE, SIZE, LOCATION, AND NUMBER OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE AS SHOWN ON THE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE AND LOCATION OF ALL UNDERGROUND UTILITIES ALONG THE ROUTE OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING UNKNOWN UNDERGROUND UTILITIES. 3. THESE PLANS HAVE BEEN REVIEWED BY THE CITY FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BY THE REVIEWING DEPARTMENT, THE CITY ENGINEER, OR THE CITY FOR ACCURACY OR CORRECTNESS OF THE CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT THE QUANTITIES OF THE ITEMS ON THE PLANS ARE THE FINAL QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE CITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE CONSTRUCTION PHASE. 4. PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION, THE CONTRACTOR MUST GIVE THE CITY ENGINEERING DEPARTMENT (970-221-6605) AND THE EROSION CONTROL INSPECTOR (970-221-6700) TWENTY-FOUR (24) HOURS ADVANCE-NOTICE. INITIAL EROSION CONTROL MEASURES MUST BE INSTALLED AND A SITE INSPECTION BY THE EROSION CONTROL INSPECTOR IS REQUIRED BEFORE COMMENCING CONSTRUCTION ACTIVITIES. 5. MAINTENANCE OF ONSITE DRAINAGE FACILITIES SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNERS. 6. ALL RECOMMENDATIONS OF THE FINAL DRAINAGE AND EROSION CONTROL STUDY FOR THIS DEVELOPMENT BY (ENGINEERING FIRM) MUST BE MET. 7. PRIOR TO FINAL INSPECTION AND ACCEPTANCE BY THE CITY, CERTIFICATION OF THE DRAINAGE FACILITIES BY A COLORADO REGISTERED PROFESSIONAL ENGINEER MUST BE SUBMITTED TO AND APPROVED BY THE CITY STORMWATER DEPARTMENT. FOR COMMERCIAL AND MULTI-FAMILY DEVELOPMENTS, CERTIFICATION OF ALL DRAINAGE FACILITIES SHALL BE SUBMITTED TO THE CITY STORMWATER DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF A CERTIFICATE OF OCCUPANCY. INDIVIDUAL LOT CERTIFICATION, ELEVATION CERTIFICATION, OR FLOODPROOFING CERTIFICATION, AS SPECIFIED IN THE DEVELOPMENT AGREEMENT, MUST BE SUBMITTED TO THE CITY STORMWATER DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF A CERTIFICATE OF OCCUPANCY FOR SUCH LOT. 8. IF DEWATERING IS USED TO INSTALL UTILITIES, AND DISCHARGE WILL BE INTO THE STREET, GUTTER, STORM SEWER, CHANNEL, IRRIGATION DITCH, OR ANY WATERS OF THE STATE A STATE CONSTRUCTION DEWATERING INDUSTRIAL WASTEWATER DISCHARGE PERMIT IS REQUIRED. 9. ALL LAND DISTURBING ACTIVITIES GREATER THAN OR EQUAL TO ONE ACRE MUST COMPLY WITH THE STATE OF COLORADO PERMITTING PROCESS FOR STORMWATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITY. FOR MORE INFORMATION CONTACT THE COLORADO DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT, WATER QUALITY CONTROL DIVISION, AT 303-692-3500 OR REFER TO THE WEB SITE AT HTTP://WWW.CDPHE.STATE.CO.US/WQ/PERMITSUNIT/ . 10. BENCHMARK: NATIONAL GEODETIC SURVEY BENCHMARK "C322 RESET 1959" NAVD 88 ELEVATION: 4989.40 A STANDARD 3 1/2 INCH U.S. CONSTRUCTION AND GEODETIC SURVEY BRASS BENCHMARK DISK SET IN THE TOP OF A CONCRETE WALL ON THE NORTH SIDE OF SPRING CREEK. LOCATED 47 FEET WEST OF THE CENTERLINE OF COLLEGE AVENUE (AKA U.S. HIGHWAY 287) AND 3,566 FEET NORTH OF THE CENTERLINE OF DRAKE STREET. 11. IF FILL OR DREDGED MATERIAL IS DISCHARGED INTO WATERS OF THE UNITED STATES, A USACE 404 PERMIT IS REQUIRED. 12. IF CONSTRUCTION AFFECTS ANY COLORADO HIGHWAY, A COLORADO DEPARTMENT OF TRANSPORTATION RIGHT-OF-WAY PERMIT IS REQUIRED. SCALE: 1"=50' 0 10 20 50 GENERAL DRAINAGE NOTES 1. NO BUILDING, STRUCTURE, OR FILL WILL BE PLACED IN THE DETENTION AREAS AND CHANGES OR ALTERATIONS AFFECTING THE HYDRAULIC CHARACTERISTICS OF THE DETENTION AREAS WILL BE MADE WITHOUT THE APPROVAL OF THE CITY ENGINEER. 2. MAINTENANCE AND OPERATION OF THE DETENTION AND WATER QUALITY AREAS IS THE RESPONSIBILITY OF PROPERTY OWNER. IF OWNER FAILS IN THIS RESPONSIBILITY, THE CITY HAS THE RIGHT TO ENTER THE PROPERTY, MAINTAIN THE DETENTION AREAS, AND BE REIMBURSED FOR COSTS INCURRED. 3. DETENTION POND VOLUMES, ALL DRAINAGE APPURTENANCES, AND BASIN BOUNDARIES SHALL BE VERIFIED. AS-BUILT DRAWINGS SHALL BE PREPARED BY A REGISTERED PROFESSIONAL ENGINEER PRIOR TO ISSUANCE OF CERTIFICATE OF OCCUPANCY. 4. PERMISSION TO REPRODUCE THESE PLANS IS HEREBY GIVEN TO THE CITY OF LITTLETON FOR CITY PURPOSES ASSOCIATED WITH PLAN REVIEW, APPROVAL, PERMITTING, INSPECTION AND CONSTRUCTION OF THE WORK. 5. ALL PROPOSED CURB AND GUTTER FOR THE SITE SHALL BE 6" VERTICAL CURB AND GUTTER W/ A 1' PAN. Tributary Area tc | 2-Year tc | 100-Year Q2 Q100 Sub-basin (acres) (min) (min) (cfs) (cfs) OS-1 0.15 0.85 1.00 5.0 5.0 0.4 1.5 A-1 0.63 0.85 1.00 5.0 5.0 1.5 6.3 A-2 0.26 0.86 1.00 5.0 5.0 0.6 2.6 A-3 0.19 0.91 1.00 5.0 5.0 0.5 1.9 A-4 0.75 0.90 1.00 5.0 5.0 1.9 7.5 A-5 0.11 0.95 1.00 5.0 5.0 0.3 1.1 A-6 0.30 0.78 0.97 5.0 5.0 0.7 2.9 A-7 0.92 0.90 1.00 5.4 5.0 2.3 9.2 A-8 0.37 0.81 1.00 5.0 5.0 0.9 3.7 A-9 0.42 0.90 1.00 5.0 5.0 1.1 4.2 A-10 0.67 0.90 1.00 5.0 5.0 1.7 6.7 A-11 0.11 0.95 1.00 5.0 5.0 0.3 1.1 A-12 0.32 0.74 0.92 5.0 5.0 0.7 3.0 A-13 0.45 0.87 1.00 5.0 5.0 1.1 4.5 B-1 1.11 0.88 1.00 5.2 5.0 2.8 11.1 B-2 1.31 0.89 1.00 5.0 5.0 3.3 13.1 B-3 1.38 0.87 1.00 5.0 5.0 3.4 13.8 C-1 0.74 0.92 1.00 5.0 5.0 1.9 7.4 C-2 0.29 0.92 1.00 5.0 5.0 0.8 2.9 D-1 0.66 0.65 0.82 12.3 10.5 0.9 4.2 E-1 0.15 0.85 1.00 5.0 5.0 0.4 1.5 BASIN SUMMARY TABLE C2 C 100 SITE VICINITY MAP NOT TO SCALE RDG PJD NOVEMBER 2016 DRAINAGE PLAN 11 BASIS OF BEARING THE EAST LINE OF THE SOUTHEAST QUARTER OF SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PM. BEING MONUMENTED AT THE NORTH END BY A 2-1/2" ALUMINUM CAP, AND AT THE SOUTH END BY A 3" ALUMINUM CAP, IS ASSUMED TO BEAR N 00°18'00" W, WITH A DISTANCE OF 2640.61 FEET BETWEEN SAID MONUMENTS. CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. CITY ENGINEER DATE DATE DATE DATE DATE STORMWATER UTILITY PARKS & RECREATION TRAFFIC ENGINEER DATE APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: WATER & WASTEWATER UTILITY CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL ENVIRONMENTAL PLANNER WV SS 3.66% 0.78% 0.78% 1.61% 2.10% 3.37% 1.91% 2.31% 1.69% 2.77% 1.14% 3.84% 0.56% 1.15% 1.93% 2.09% 3.58% 2.14% 1.76% 1.29% 1.8 8% 1.25% 2.02% 1.78% 1.77% 1.41% 3.28% 3.34% 1.74% 1.50% 1.61% 3.06% 1.78% 2.56% 2.10% 2.88% 2.44% 1.02% 3.43% 1.75% 1 .70% 2.13% 2.49% 1.48% 3.92% 1.46% 1.12% 0.74% 2.46% 2.78% 3.05% 1.54% 2.39% 3.47% 1.93% 1.61% 0.89% 3.10% 2.13% 1.50% 1.50 % 1 RxDRIVE THRU GROCERY PICK UP 2 3 4 MARKETPLACE 119,000 SF STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM 18"STM LOT 1 487,410 SF (11.189 AC) # 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 O www.gallowayUS.com C 2016. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By: H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_10-Grad.dwg - Rob Gordon - 2015-04-16 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT King Soopers Marketplace 65 Tejon Street Denver, CO 80223 Phone (303) 778-3053 Fax (303) 871-9262 KSS000146 RDG PJD NOVEMBER 2016 OVERALL GRADING PLAN 10 SCALE: 1"=50' 0 10 20 50 PROPOSED TOP OF CURB ELEVATION PROPOSED FLOWLINE ELEVATION EXISTING STORM SEWER PROPOSED STORM SEWER (12" AND LARGER) STM PROPOSED SPOT ELEVATION PROPOSED CONTOUR ME MATCH EXISTING FLOWLINE HIGH POINT FL HP LPPOINT LOW TC TOP OF CURB TOG TOP OF GRATE 39 FF FINISHED FLOOR GRADING LEGEND 39CONTOUR EXISTING GB GRADE BREAK FL INT PCR POINT OF CURB RETURN FLOWLINE INTERSECTION CO CURB OPENING TOB TOP OF BERM PC POINT OF CURVE STM 40.0 40.5 40.0 TOSSIDEWALK TOP OF C S SPILL CURB AND GUTTER CATCH CURB AND GUTTER 40 PROPOSED CONTOUR 40CONTOUR EXISTING BASIS OF BEARING THE EAST LINE OF THE SOUTHEAST QUARTER OF SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PM. BEING MONUMENTED AT THE NORTH END BY A 2-1/2" ALUMINUM CAP, AND AT THE SOUTH END BY A 3" ALUMINUM CAP, IS ASSUMED TO BEAR N 00°18'00" W, WITH A DISTANCE OF 2640.61 FEET BETWEEN SAID MONUMENTS. BENCHMARK NATIONAL GEODETIC SURVEY BENCHMARK "C322 RESET 1959" NAVD 88 ELEVATION: 4989.40 A STANDARD 3 1/2 INCH U.S. CONSTRUCTION AND GEODETIC SURVEY BRASS BENCHMARK DISK SET IN THE TOP OF A CONCRETE WALL ON THE NORTH SIDE OF SPRING CREEK. LOCATED 47 FEET WEST OF THE CENTERLINE OF COLLEGE AVENUE (AKA U.S. HIGHWAY 287) AND 3,566 FEET NORTH OF THE CENTERLINE OF DRAKE STREET. CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. CITY ENGINEER DATE DATE DATE DATE DATE STORMWATER UTILITY PARKS & RECREATION TRAFFIC ENGINEER DATE APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: WATER & WASTEWATER UTILITY CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL ENVIRONMENTAL PLANNER EASEMENT SCHEDULE NOTE: THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATION REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. STM PROPOSED STORM SEWER (LESS THAN 12") NOTE: SEE LANDSCAPE AND EROSION CONTROL PLANS FOR METHOD OF REVEGATATION . EXISTING 6' UTILITY EASEMENT; REF. PLAT EXISTING 15' UTILITY EASEMENT; REF. PLAT EXISTING 20' UTILITY EASEMENT; REF. PLAT EXISTING 40' UTILITY EASEMENT; REF. PLAT EXISTING 10' DRAINAGE EASEMENT; REF. PLAT EXISTING TRAFFIC EASEMENT TO BE VACATED; REF. PLAT EXISTING SHARED PARKING EASEMENT; REF. PLAT EXISTING 40' UNDERGROUND UTILITY EASEMENT; REF. PLAT PROPOSED 20' WATER EASEMENT; REF. PLAT PROPOSED UTILITY EASEMENT; REF. PLAT PROPOSED TRAFFIC EASEMENT; REF. PLAT EXISTING 6' GAS AND POWER EASEMENT; REF. PLAT PROPOSED SPOT ELEVATION 8 10 11 12 13 14 15 17 18 19 ADA PARKING SYMBOL (SEE DETAIL, SHEET 8)(TYP.) 4" TRAFFIC YELLOW STRIPING AT 2'-0" KING SOOPERS NOTE: ANY ADA SPACE CAN BE VAN ACCESSIBLE DUE TO WIDER 11' STALLS AND STANDARD 5' ACCESS AISLES PROPOSED KING SOOPERS WEST ENTRY CROSSWALK AND ADA PARKING DETAILS 4" TRAFFIC YELLOW STRIPING AT 2'-0" KING SOOPERS 4" TRAFFIC YELLOW STRIPING AT 2'-0" ADA SIGNAGE (SEE DETAIL, SHEET 8) (TYP.) 5' ACCESS AISLE 5' ACCESS AISLE 9' ACCESSIBLE SPACE PROPOSED KING SOOPERS EAST ENTRY CROSSWALK AND ADA PARKING DETAILS SCALE: 1"=10' 9' TYP CITY ENGINEER DATE DATE DATE DATE DATE STORMWATER UTILITY PARKS & RECREATION TRAFFIC ENGINEER DATE APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: WATER & WASTEWATER UTILITY CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL ENVIRONMENTAL PLANNER NOTE: ANY ADA SPACE CAN BE VAN ACCESSIBLE DUE TO WIDER 11' STALLS AND STANDARD 5' ACCESS AISLES 9' ACCESSIBLE SPACE 9' ACCESSIBLE SPACE 9' ACCESSIBLE SPACE 9' ACCESSIBLE SPACE 9' ACCESSIBLE SPACE 9' 9' ACCESSIBLE SPACE 9' 9' ACCESSIBLE SPACE 5' ACCESS AISLE 5' ACCESS AISLE 9' ACCESSIBLE SPACE 5' ACCESS AISLE 9' ACCESSIBLE SPACE 5' ACCESS AISLE 9' ACCESSIBLE SPACE 9' ACCESSIBLE SPACE 5' ACCESS AISLE 9' ACCESSIBLE SPACE 9' ACCESSIBLE SPACE 9' ACCESSIBLE SPACE 5' ACCESS AISLE 9' ACCESSIBLE SPACE 5' ACCESS AISLE 9' ACCESSIBLE SPACE 9' ACCESSIBLE SPACE 21' 5.9' 21.1' 48' 4' 21' 21' 4' 50' 9' TYP ADA SIGNAGE (SEE DETAIL, SHEET 8) (TYP.) ADA PARKING SYMBOL (SEE DETAIL, SHEET 8)(TYP.) 4" TRAFFIC YELLOW STRIPING AT 2'-0" STREET CURB 3' 22F12-A3PG 2 1/4'' ANCHOR THE UNIFORM TRAFFIC TYPICAL AS STATED IN MANUAL CONTROL DEVICES STOP 3'' 3'' 7' MIN 2' MIN TWO TL-3806CP DRIVE RIVETS 30'' x 30'' SIGN (.100 GA) WITH TWO TL-3806CP DRIVE RIVETS (SIGN TYPE R1-1) 3" 3" 3' 3" 3" 3' WHITE PROVIDE TWO COATS BLUE BACKGROUND WITH WHITE SYMBOL 2. 1. NOTE: OF PAINT BLUE MATERIAL: .060 ALUMINUM - BLUE BACKGROUND WITH 1 1/2" RADIUS CORNERS WHITE 2 MOUNTING HOLES 2 1/4" WHITE COPY AND BORDER 1/4" 1 1/8" 12" 1/4" 1 1/8" 2 1/4" 8" NOTE: WHERE SIGN IS LOCATED IN PLANTER AREA, USE 2" x 2" TUBE STEEL FULL LENGTH AND SET IN CONCRETE 3'-0" MIN. BELOW GRADE. 16" DIAMETER x 36" DEEP CONCRETE FOUNDATION CADMIUM PLATED BOLTS, NUTS, BOLT TO STEEL TUBE WITH 1/2" SYMBOL AND "VAN ACCESSIBLE" PARKING" WITH IDENTIFICATION WHERE APPLICABLE. YELLOW CENTERED IN FOUNDATION, PAINTED 4" x 6'-0" CONCRETE FILLED STEEL POST ON GREEN ENAMEL FINISH U-CHANNEL POST WITH BAKED 2-1/4" x 6'-0" LONG PAVING TOW AWAY ZONE PARKING RESERVED AND WASHERS. SIGN TO READ "RESERVED SIGN WITH WHITE LETTERS ON 12" x 18" FLAT SCREEN STEEL 4" CONCRETE BRICK TYPICAL BLUE BACKGROUND TO COMPLY WITH ADA GUIDELINES. 4'-0" TYPICAL MATERIAL: .060 ALUMINUM - WHITE BACKGROUND WITH BLUE COPY AND BORDER - SYMBOL HAS BLUE BACKGROUND, WHITE COPY WITH BLACK BORDER 1 1/2" RADIUS CORNERS WHITE 2 MOUNTING HOLES 8'-0" 2'-0" 2'-0" 10'-0" (VARIES) 2'-0" TYP. DRIVE CENTERLINE WHITE STOP BAR TO DRIVE CENTERLINE WHITE CROSSWALK BAR TOTAL NUMBER OF BARS VARIES 8'-0" 6'-3" LENGTH VARIES 8'-0" 11.5" 6'-1" 6'-1" 11.5" 9'-6" 5'-1" 3'-2" THRU ARROW TURN ARROW CENTER ON DRIVE CENTER ON LANE WHITE SYMBOLS CENTER IN LANE 2'' POST - 20F12PG TELESTAR TUBING SOLID 12 GAUGE (NO PERFORATIONS) CONCRETE FOOTING PAVING TOP OF 1'-6"Ø 3" 3'-0" 4'-0" 1 1/2" PROVIDE DOMED CEMENT WASH CAP 6" DIA. STEEL PIPE BOLLARD FILLED WITH CONCRETE PAINT PIPE (2) COATS "SIERRA TAN" PAVEMENT PROVIDE AT VAN DESIGNATED SPACES ONLY VARIES SEE PLAN 1/4" PER 1' CROSS SLOPE EXPANSION JOINTS NOT REQUIRED BETWEEN CURB AND SIDEWALK LONGITUDINAL JOINTS REQUIRED IF WIDTH EXCEEDS 8 FEET PANEL SHALL BE AS NEAR SQUARE AS POSSIBLE 1. CONTRACTION JOINTS SHALL BE SPACED SO AS TO FORM AS NEAR SQUARE PANEL AS POSSIBLE, NO SINGLE PANEL SHALL EXCEED 8' ON ANY SIDE. CONTRACTION JOINTS SHALL BE 3/4" DEEP. 2. EXPANSION JOINTS OF 1/2" MASTIC MATERIAL SHALL BE PLACED AT THE FOLLOWING LOCATIONS: P.C.S AND P.T.S OF CURVES GRADE BREAKS AT DRIVEWAYS AT OTHER LOCATIONS AS SPECIFIED BY ENGINEER 3. NO SIDEWALK SHALL BE PLACED WITHOUT A FINAL FORM INSPECTION BY THE ENGINEER 4. CONSTRUCTION MATERIALS AND PROCEDURES SHALL CONFORM TO EXISTING CITY AND STATE STANDARD SPECIFICATIONS. WATER TIGHT PLUG OR CAP SERVICE PIPE 2"x4" MARKER 2"x6" CEDAR OR REDWOOD BLOCKING 1'-0" THREE 6" DIA. COILS MIN. 4'-0" PAINT EACH MARKER PER EXTEND 2"x4" MARKER AND COLOR CODE FOR UTILITY 12 GAUGE GALVANIZED WIRE (SHALL BE FASTENED TO THE BOTTOM ONLY OF 2"X4" STAKE) LOCATES. WATER BLUE TELEPHONE ORANGE GAS YELLOW RED UTILITY COLOR ELECTRIC SEWER GREEN 1:12 SLOPE UP MAX. ELEVATION PLAN 6" CURB RAMP 6'-0" MIN. 0.5' VARIES - 3' MIN. 0.5' RAMP (SEE PLAN) 4'-0" 4'-0" 8'-0" 2" WW 6x6x4.4 OR #4 @ 18" EW 6" 3" CLEARANCE CONCRETE COMPACTED SUBGRADE GROVED DETECTABLE WARNING SURFACE PER A.D.A. 4.29.2 RIGHT LANE TURN RIGHT 1 1/2" R PAVING VARIES TOOLED EDGE 1/4" RADIUS NOTES: SEE NOTE 1 12" 6" 4 1/2" 12" 6" 6" 1 1/2" LEVEL WITH TOP FINISHED LANDSCAPING SIDEWALK OR OF CURB GUTTER CROSS SLOPE SHALL BE 1/2 IN./FT. WHEN DRAINING AWAY FROM CURB AND 1 IN./FT. WHEN DRAINING TOWARD CURB. BASE OF CURB SHALL REST ON COMPACTED FILL. ALL EXPOSED CONCRETE SHALL HAVE A SACK FINISH. CONTROL JOINTS SHALL BE INSTALLED AT 10 FOOT MAXIMUM INTERVALS AND AT THE END OF CURB RETURNS - SEE CURB CONTROL JOINT DETAIL. 1. 2. 3. 4. EXPANSION JOINTS SHALL BE INSTALLED AT 500 FOOT MAXIMUM INTERVALS AND/OR TO MATCH LOCATION OF EXPANSION JOINTS IN PAVING - SEE 5. CURB EXPANSION JOINT DETAIL. FL 1 1/2" R 6" 12" PAVING VARIES TOOLED EDGE 1/4" RADIUS 4 1/2" 1 1/2" 12" 6" 6" FL SIDEWALK OR FINISHED LANDSCAPING LEVEL WITH TOP OF CURB SEE NOTE 1 CURB EXPANSION JOINT DETAIL. AND/OR TO MATCH LOCATION OF EXPANSION JOINTS IN PAVING - SEE EXPANSION JOINTS SHALL BE INSTALLED AT 500 FOOT MAXIMUM INTERVALS AND AT THE END OF CURB RETURNS - SEE CURB CONTROL JOINT DETAIL. CONTROL JOINTS SHALL BE INSTALLED AT 10 FOOT MAXIMUM INTERVALS FROM CURB AND 1 IN./FT. WHEN DRAINING TOWARD CURB. GUTTER CROSS SLOPE SHALL BE 1/2 IN./FT. WHEN DRAINING AWAY BASE OF CURB SHALL REST ON COMPACTED FILL. ALL EXPOSED CONCRETE SHALL HAVE A SACK FINISH. NOTES: 5. 4. 3. 2. 1. DO NOT ENTER 2 3/8"Ø LEVEL GROUND 2'-0" 3'-2 3/8" TOTAL LENGTH FOR 5 SPACE RACK 7 3 7 16" 3 16" 9 5 8" 10 1/4" 2'-11 1/4" BIKE 2 BIKE 3 BIKE 4 BIKE 5 INGROUND ANCHOR MOUNT SURFACE FLANGE MOUNT CATCH CURB & 1' WIDE GUTTER PRIVATE SPILL CURB AND 1' WIDE GUTTER PRIVATE CONTRACTION JOINTS 4" FOR SIDEWALKS NOTES: PIPE BOLLARD DETAIL (OTHER THAN AT FRONT SIDEWALK) 6" OF SUBGRADE COMPACTED TO 95% MODIFIED PROCTOR DENSITY 3" SELECT CRUSHED BASE COMPACTED TO 95%MODIFIED PROCTOR DEN SITY S. COLLEGE AVE. R.O.W. WIDTH VARIES 10 2 2 2 2 2 2 2 2 2 2 5 5 12 12 9 6 2 2 2 10 13 TYP. 13 TYP. 5 6 6 6 6 8 7 12 11 4 4 4 5 12 12 9 5 5 5 4 5 5 14 4 4 4 4 4 4 4 4 4 4 4 5 5 10 10 10 8 12 7 3 3 5 5 5 10 12 2 4 2 4 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 # 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 O www.gallowayUS.com C 2016. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By: H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_07-Sign-Strip.dwg - Rob Gordon - 2015-04-16 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT King Soopers Marketplace 65 Tejon Street Denver, CO 80223 Phone (303) 778-3053 Fax (303) 871-9262 KSS000146 RDG PJD NOVEMBER 2016 SIGNAGE AND STRIPING PLAN 7 BASIS OF BEARING THE EAST LINE OF THE SOUTHEAST QUARTER OF SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PM. BEING MONUMENTED AT THE NORTH END BY A 2-1/2" ALUMINUM CAP, AND AT THE SOUTH END BY A 3" ALUMINUM CAP, IS ASSUMED TO BEAR N 00°18'00" W, WITH A DISTANCE OF 2640.61 FEET BETWEEN SAID MONUMENTS. BENCHMARK NATIONAL GEODETIC SURVEY BENCHMARK "C322 RESET 1959" NAVD 88 ELEVATION: 4989.40 A STANDARD 3 1/2 INCH U.S. CONSTRUCTION AND GEODETIC SURVEY BRASS BENCHMARK DISK SET IN THE TOP OF A CONCRETE WALL ON THE NORTH SIDE OF SPRING CREEK. LOCATED 47 FEET WEST OF THE CENTERLINE OF COLLEGE AVENUE (AKA U.S. HIGHWAY 287) AND 3,566 FEET NORTH OF THE CENTERLINE OF DRAKE STREET. CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. CITY ENGINEER DATE DATE DATE DATE DATE STORMWATER UTILITY PARKS & RECREATION TRAFFIC ENGINEER DATE APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: WATER & WASTEWATER UTILITY CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL ENVIRONMENTAL PLANNER BASIS OF BEARING THE EAST LINE OF THE SOUTHEAST QUARTER OF SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PM. BEING MONUMENTED AT THE NORTH END BY A 2-1/2" ALUMINUM CAP, AND AT THE SOUTH END BY A 3" ALUMINUM CAP, IS ASSUMED TO BEAR N 00°18'00" W, WITH A DISTANCE OF 2640.61 FEET BETWEEN SAID MONUMENTS. BENCHMARK NATIONAL GEODETIC SURVEY BENCHMARK "C322 RESET 1959" NAVD 88 ELEVATION: 4989.40 A STANDARD 3 1/2 INCH U.S. CONSTRUCTION AND GEODETIC SURVEY BRASS BENCHMARK DISK SET IN THE TOP OF A CONCRETE WALL ON THE NORTH SIDE OF SPRING CREEK. LOCATED 47 FEET WEST OF THE CENTERLINE OF COLLEGE AVENUE (AKA U.S. HIGHWAY 287) AND 3,566 FEET NORTH OF THE CENTERLINE OF DRAKE STREET. SCALE: 1"=50' 0 10 20 50 PROPOSED PAINTED 8' INTERSECTION CROSSWALK. PAINTED STRIPES TO BE 24" AND SPACED PER LANE PROPOSED PAINTED PARKING AREA CROSSWALK; USE 4" WHITE STRIPE, AT 2' INTERVALS PROPOSED PAINTED CROSSWALK TO BUILDING (SEE DETAIL SHEET CS5.2) PROPOSED 9'x19' 90-DEGREE "HEAD-IN" PARKING STALL (TYP.) 6 PROPOSED 'R-1-1' STOP SIGN. SIGNS BACKS AND POSTS TO BE PAINTED RAL 6012 "FEDERAL 7 10 11 8 9 SCHEDULE PROPOSED 8'x15' 90-DEGREE "HEAD-IN" PARKING STALL (TYP.) PROPOSED 9.5'x21' 60-DEGREE "ANGLED" PARKING STALL (TYP.) PROPOSED ADA PARKING STALL WITH PAINTED ACCESS AISLE AND SIGNAGE (TYP. 21) 4 5 1 2 3 STRIPING NOTES 1. ALL WORKMANSHIP AND MATERIALS TO CONFORM TO THE CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS. 2. CONTRACTOR TO REMOVE ANY CONFLICTING, PREVIOUS MARKINGS, IF ANY, PER CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS. 3. ALL TRAFFIC LANE AND INFORMATIONAL MARKINGS TO CONFORM TO THE CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS. 4. ALL REMOVALS SHALL BE BY GRINDING, SANDBLASTING OR CHEMICAL METHODS PROVIDED THAT THE PAVEMENT SURFACE SHALL NOT BE MATERIALLY DAMAGED. THE PAVEMENT MARKINGS SHALL BE REMOVED TO THE EXTENT THAT THEY SHALL NOT BE VISIBLE UNDER DAY OR NIGHT CONDITIONS. 5. ALL SIGNAGE SHALL CONFORM TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, LATEST EDITION. 6. ALL ONSITE STRIPING TO BE PAINTED WHITE AND 4" WIDE UNLESS SPECIFIED OTHERWISE. 12 13 PROPOSED STOP BAR AND TRAFFIC DIRECTIONAL FLOW ARROW PROPOSED HANDICAP PARKING SIGNS. ALL SIGN BACKS AND POSTS TO BE PAINTED RAL 6012 "FEDERAL GREEN" (SEE SHEET CS5.2) (ALSO SEE HANDICAP PARKING AREA DETAIL SHEET CS5.2) GREEN" (SEE SHEET CS5.2 FOR DETAIL) DISTRIBUTION (TRIPLE PAINT COAT) (SEE PLAN FOR 24" STRIPE LOCATIONS) 4" WIDE SOLID YELLOW, DOUBLE CENTER LINES. LENGTH OF CENTER LINES AS SHOWN ON PLAN (TRIPLE PAINT COAT) PROPOSED PARKING STRIPING PROPOSED STRIPED ISLAND: USE 4" WHITE STRIPE AT 2' INTERVALS E:117462.85 ELEV: 5017.61 N:445115.26 E:117463.91 ELEV: 5017.39 SECTION LINE PROPERTY LINE 5' 37.3' 6' 2.5' 4.2' 1.5' 1.5' 1' EXISTING MEDIAN CURB AND GUTTER TO REMAIN EXISTING ASPHALT TO REMAIN SAWCUT LINE SAWCUT LINE PROPOSED FULL DEPTH ASPHALT PATCHBACK PROPOSED FULL DEPTH ASPHALT PATCHBACK DRAKE ROAD PROPOSED 4" THICK CONCRETE BUS STOP PAD AND SIDEWALK 10.1' 2.8' 5' BIKE PATH 12' TRAVEL LANE 12' TRAVEL LANE 13.3' TRANSITION LANE # 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 O www.gallowayUS.com C 2016. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By: H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_06-Intersect.dwg - Phil Dalrymple - 2015-04-16 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT King Soopers Marketplace 65 Tejon Street Denver, CO 80223 Phone (303) 778-3053 Fax (303) 871-9262 KSS000146 RDG PJD NOVEMBER 2016 INTERSECTIONS PLAN 6 BASIS OF BEARING THE EAST LINE OF THE SOUTHEAST QUARTER OF SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PM. BEING MONUMENTED AT THE NORTH END BY A 2-1/2" ALUMINUM CAP, AND AT THE SOUTH END BY A 3" ALUMINUM CAP, IS ASSUMED TO BEAR N 00°18'00" W, WITH A DISTANCE OF 2640.61 FEET BETWEEN SAID MONUMENTS. BENCHMARK NATIONAL GEODETIC SURVEY BENCHMARK "C322 RESET 1959" NAVD 88 ELEVATION: 4989.40 A STANDARD 3 1/2 INCH U.S. CONSTRUCTION AND GEODETIC SURVEY BRASS BENCHMARK DISK SET IN THE TOP OF A CONCRETE WALL ON THE NORTH SIDE OF SPRING CREEK. LOCATED 47 FEET WEST OF THE CENTERLINE OF COLLEGE AVENUE (AKA U.S. HIGHWAY 287) AND 3,566 FEET NORTH OF THE CENTERLINE OF DRAKE STREET. SCALE: 1"=20' 0 10 20 CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. CITY ENGINEER DATE DATE DATE DATE DATE STORMWATER UTILITY PARKS & RECREATION TRAFFIC ENGINEER DATE APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: WATER & WASTEWATER UTILITY CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL ENVIRONMENTAL PLANNER SCALE: 1"=20' 0 10 20 DRAKE ROAD INTERSECTION PLAN AND BUS PULL OUT DETAIL SCALE: 1"=20' SOUTH COLLEGE AVENUE INTERSECTION PLAN SCALE: 1"=20' PROPERTY BOUNDARY LINE ADJACENT PROPERTY BOUNDARY LINE EXISTING EASEMENT BOUNDARY LINE SAWCUT LINE EXISTING SANITARY SEWER MANHOLE EXISTING GAS METER EXISTING ELECTRICAL MANHOLE EXISTING WATER VALVE EXISTING FENCE EXISTING TRAIN TRACTS EXISTING FIRE HYDRANT EXISTING ELECTRICAL BOX LEGEND X X X X EXISTING ELECTRICAL METER/RISER EXISTING WATER METER EXISTING LIGHT POLE EXISTING TELEPHONE MANHOLE EXISTING TELEPHONE RISER EXISTING IRRIGATION BOX EM SECTION LINE WV WM SS CO D Y H IR ECB TL E EVT GM RI E EXISTING SANITARY SEWER CLEANOUT EXISTING ELECTRICAL CABINET EXISTING ELECTRICAL VAULT EXISTING EXISTING TREE TO REMAIN EXISTING SIGN EXISTING STORM SEWER CURB INLET EXISTING STORM SEWER AERA INLET PROPOSED FIRE HYDRANT PROPOSED MANHOLE COVER PROPOSED INLET EXISTING EASEMENT BOUNDARY LINE TO BE REMOVED PROPOSED EASEMENT BOUNDARY LINE PROPOSED SITE LIGHTING PROPOSED SIGN 36.5' 12.5' 12' 12' 6' 19.7' 84.3' PROPOSED CONCRETE CROSSPAN R20' R20' 4.2' 19.9' 36.5' 20.1' 2.4' 8' PROPOSED CURB AND GUTTER; REFERENCE SITE DETAILS, SHEET 8 PROPOSED WHITE TRAFFIC SYMBOLS; REFERENCE SITE DETAILS, SHEET 8 PROPOSED 2' SOLID WHITE STROP BAR; REFERENCE SITE DETAILS, SHEET 8 PROPOSED CURB AND GUTTER; REFERENCE SITE DETAILS, SHEET 8 PROPOSED ADA RAMP; REFERENCE SITE DETAILS, SHEET 8 PROPOSED ADA RAMP; REFERENCE SITE DETAILS, SHEET 8 PROPOSED SIDEWALK; REFERENCE SITE DETAILS, SHEET 8 PROPOSED SOLID WHITE CROSSWALK BAR; REFERENCE SITE DETAILS, SHEET 8 SECTION A-A SCALE: 1"=20' 4" SOLID WHITE LANE LINE 4" DOUBLE YELLOW LANE LINE PROPOSED HEAVY DUTY ASPHALT X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X G G G UT UT UT E IR IR IR EVT ECB GM N0°22'28"E 2640.62' BASIS OF BEARINGS E E E E TL TL TV RI SD SD E ECB EM E TL GM IR TL EXISTING BUILDING TO REMAIN ONE STORY BUILDING ONE STORY BUILDING TO REMAIN DRAKE ROAD 100' RIGHT OF WAY S. COLLEGE AVE. R.O.W. WIDTH VARIES SD SD SD 24' 21' 21' 24' 21' 21' 24' 21' 21' 33.8' 21' 6' 21' 24' 21' 21' 24' 21' 21' 4.1' 24' 21' 21' 24' 21' 21' 19' 9.6' 19' 19' 24' 19' 19' 36.6' 33' 24' 24' 6' 18.8' 6.5' 15.6' 24' 24.9' 9' 9' 5' 9' 9' 9' 9' 9' 9' TYP TYP TYP TYP TYP TYP TYP TYP 13.3' 19' 24' 15' 15' 24' 19' 19' 24' 19' 19' 24' 19' 35.4' 29.9' 36.1' 34.7' 60.3' 2' 5' 9' TYP 18' 9' TYP 9' TYP 9' TYP 9' TYP 30' 30' 26.1' 24.7' 11.3' 48.5' 32.2' 19.1' 22.9' 92.3' 7.7' R5.5' R10' R7' R4' R4' R4' R2' R10' R10' R7' R30' R30' R10' R8' R10' R3' R3' R3' R10' R10' R3' R3' R10' R10' R3' R15' R10' R3' R3' R R10' 3' R3' R10' R3' R3' R3' R3' R3' R3' R3' R3' R3' R10' R3' R10' R3' R3' R3' R10' R3.5' R3' R10' R3.5' R3.5' R3.5' R3' R3' R10' R10' R165' R10' R3' R3' R3' R3' R3' R10' R10' R3' R3' R10' R10' R3' R3' R10' R3' R3' R10' R3' R10' R3' R3' R15' R3' R8' R50' R10' R3' R3' R10' R80' R10' R3' R3' R3' R3' R10' R3' R3' R3' R3' R3' R10' R10' R3' R10' R3' R10' R3' R10' R3' R3' R3' R3' R3' R3' R10' R5' R10' R10' R3' R3' R15' R3' R3' R3' R3' R3' R10' R10' R3' R3' R10' R10' R20' R3' R3' R20' R20' R20' 79.1' 39.3' 33.7' 79.8' 255.5' 460' 260.2' 41' 241.3' 19.9' 18.1' 16.9' 20.6' 30' 13.8' 8.5' 6' 10' 6' 6' 15.6' 19' 12.5' 10.5' 24' 19' 7' 12' 10' R10' R10' R3' R3' R10' R3' R3' R10' R3' R10' R3' R3' R3' R3' R3' R10' R13' R3' R3' R3' R10' R15' R3' R3' R3' R3' R10' R10' R10' R3' R10' R3' R10' R3' R10' R3' R10' R10' R10' R3' R3' R10' R3' R62' R50' R62' R50' R100' R50' R62' R18' R30' R62' R50' R3' R30' R18' R32' R20' 6' 6' 5.9' 3.6' 6' R135' 8.4' 6' TYP. SEE INTERSECTION PLAN FOR DETAILS SEE INTERSECTION PLAN FOR DETAILS # 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 O www.gallowayUS.com C 2016. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By: H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_05-HCP.dwg - Rob Gordon - 2015-04-16 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT King Soopers Marketplace 65 Tejon Street Denver, CO 80223 Phone (303) 778-3053 Fax (303) 871-9262 KSS000146 RDG PJD NOVEMBER 2016 HORIZONTAL CONTROL PLAN 5 BASIS OF BEARING THE EAST LINE OF THE SOUTHEAST QUARTER OF SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PM. BEING MONUMENTED AT THE NORTH END BY A 2-1/2" ALUMINUM CAP, AND AT THE SOUTH END BY A 3" ALUMINUM CAP, IS ASSUMED TO BEAR N 00°18'00" W, WITH A DISTANCE OF 2640.61 FEET BETWEEN SAID MONUMENTS. BENCHMARK NATIONAL GEODETIC SURVEY BENCHMARK "C322 RESET 1959" NAVD 88 ELEVATION: 4989.40 A STANDARD 3 1/2 INCH U.S. CONSTRUCTION AND GEODETIC SURVEY BRASS BENCHMARK DISK SET IN THE TOP OF A CONCRETE WALL ON THE NORTH SIDE OF SPRING CREEK. LOCATED 47 FEET WEST OF THE CENTERLINE OF COLLEGE AVENUE (AKA U.S. HIGHWAY 287) AND 3,566 FEET NORTH OF THE CENTERLINE OF DRAKE STREET. SCALE: 1"=50' 0 10 20 50 LEGEND CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. CITY ENGINEER DATE DATE DATE DATE DATE STORMWATER UTILITY PARKS & RECREATION TRAFFIC ENGINEER DATE APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: WATER & WASTEWATER UTILITY CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL ENVIRONMENTAL PLANNER PROPERTY BOUNDARY LINE ADJACENT PROPERTY BOUNDARY LINE EXISTING EASEMENT BOUNDARY LINE SAWCUT LINE EXISTING SANITARY SEWER MANHOLE EXISTING GAS METER EXISTING ELECTRICAL MANHOLE EXISTING WATER VALVE EXISTING FENCE EXISTING TRAIN TRACTS EXISTING FIRE HYDRANT EXISTING ELECTRICAL BOX X X X X EXISTING ELECTRICAL METER/RISER EXISTING WATER METER EXISTING LIGHT POLE EXISTING TELEPHONE MANHOLE EXISTING TELEPHONE RISER EXISTING IRRIGATION BOX EM SECTION LINE WV WM SS CO D Y H IR ECB TL E EVT GM RI E EXISTING SANITARY SEWER CLEANOUT EXISTING ELECTRICAL CABINET EXISTING ELECTRICAL VAULT EXISTING EXISTING TREE TO REMAIN EXISTING SIGN EXISTING STORM SEWER CURB INLET EXISTING STORM SEWER AERA INLET PROPOSED FIRE HYDRANT PROPOSED MANHOLE COVER PROPOSED INLET EXISTING EASEMENT BOUNDARY LINE TO BE REMOVED PROPOSED EASEMENT BOUNDARY LINE PROPOSED SITE LIGHTING PROPOSED SIGN ARCHITECTURAL SCOPE; REFERENCE ARCHITECTURAL PLANS FOR PAVING/CONTROL DETAILS CURVE TABLE CURVE C1 C2 C3 C4 C5 C6 RADIUS 62.19 50.00 40.00 40.00 50.00 74.60 LENGTH 23.53 17.65 8.99 12.40 5.77 37.88 DELTA 21°40'32" 20°13'24" 12°52'23" 17°45'47" 6°36'58" 29°05'37" BEARING S08°29'26"E S09°14'59"E N82°54'36"W S81°46'19"W S76°11'54"W N13°20'23"W CHORD 23.39 17.56 8.97 12.35 5.77 37.48 LINE TABLE LINE L11 L12 L13 LENGTH 10.23 52.32 31.67 BEARING S22°29'22"W N76°28'25"W S72°53'25"W TO REMAIN DRAKE ROAD 100' RIGHT OF WAY S. COLLEGE AVE. R.O.W. WIDTH VARIES SD SD SD SS 12 12 55 12 31 14 55 55 12 19 42 42 55 14 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 44 44 44 44 44 44 44 44 44 44 47 TYP. 47 TYP. 47 TYP. 47 TYP. 47 TYP. 47 TYP. 30 30 46 46 46 46 46 46 46 46 45 45 46 46 46 46 46 46 36 36 36 36 36 36 36 16 31 TYP. 50 51 50 43 43 44 44 33 42 33 30 55 33 1 42 49 17 48 50 42 30 55 47 TYP. 70 1 55 55 33 33 55 30 44 43 43 50 50 30 51 51 26 26 51 28 31 TYP. 16 30 46 43 33 42 4 28 55 28 3 11 1 3 1 11 1 4 1 3 3 1 48 48 1 5 6 8 1 33 39 42 55 50 37 56 7 1 5 6 1 1 50 8 7 12 30 42 42 33 33 42 7 53 34 33 42 33 25 30 53 12 53 2 42 42 31 16 9 68 40 54 55 30 35 20 32 29 21 20 23 30 54 16 12 33 33 55 30 9 54 30 35 18 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 12 30 35 16 27 8 24 29 29 14 5 6 5 7 44 39 21 38 22 46 12 4 46 30 44 37 37 37 37 37 37 37 46 47 TYP. 37 37 37 37 37 37 37 37 37 37 37 37 37 37 13 24 24 53 24 14 24 53 24 49 24 54 48 48 48 48 33 10 30 49 49 49 49 48 48 48 48 48 48 48 LOT 2 EXTENTION OF K-MART PLAZA 49 51 51 54 48 48 48 48 48 48 48 10 10 54 27 49 54 10 54 55 55 14 49 48 5 8 14 RIGHT OF WAY DEDICATION RIGHT OF WAY DEDICATION 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 7 7 52 # 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 O www.gallowayUS.com C 2016. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By: H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_04-Site.dwg - Rob Gordon - 2015-04-16 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT King Soopers Marketplace 65 Tejon Street Denver, CO 80223 Phone (303) 778-3053 Fax (303) 871-9262 KSS000146 RDG PJD NOVEMBER 2016 OVERALL SITE PLAN 4 BASIS OF BEARING THE EAST LINE OF THE SOUTHEAST QUARTER OF SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PM. BEING MONUMENTED AT THE NORTH END BY A 2-1/2" ALUMINUM CAP, AND AT THE SOUTH END BY A 3" ALUMINUM CAP, IS ASSUMED TO BEAR N 00°18'00" W, WITH A DISTANCE OF 2640.61 FEET BETWEEN SAID MONUMENTS. BENCHMARK NATIONAL GEODETIC SURVEY BENCHMARK "C322 RESET 1959" NAVD 88 ELEVATION: 4989.40 A STANDARD 3 1/2 INCH U.S. CONSTRUCTION AND GEODETIC SURVEY BRASS BENCHMARK DISK SET IN THE TOP OF A CONCRETE WALL ON THE NORTH SIDE OF SPRING CREEK. LOCATED 47 FEET WEST OF THE CENTERLINE OF COLLEGE AVENUE (AKA U.S. HIGHWAY 287) AND 3,566 FEET NORTH OF THE CENTERLINE OF DRAKE STREET. SCALE: 1"=50' 0 10 20 50 SCHEDULE PROPERTY BOUNDARY LINE ADJACENT PROPERTY BOUNDARY LINE EXISTING EASEMENT BOUNDARY LINE SAWCUT LINE 1 EXISTING SANITARY SEWER MANHOLE EXISTING GAS METER EXISTING ELECTRICAL MANHOLE EXISTING WATER VALVE EXISTING FENCE EXISTING TRAIN TRACTS EXISTING FIRE HYDRANT EXISTING ELECTRICAL BOX LEGEND X X X X EXISTING ELECTRICAL METER/RISER EXISTING WATER METER EXISTING LIGHT POLE EXISTING TELEPHONE MANHOLE EXISTING TELEPHONE RISER EXISTING IRRIGATION BOX EM SECTION LINE WV WM SS CO D Y H IR ECB TL E EVT GM RI E EXISTING SANITARY SEWER CLEANOUT EXISTING ELECTRICAL CABINET EXISTING ELECTRICAL VAULT EXISTING EXISTING TREE TO REMAIN EXISTING SIGN EXISTING STORM SEWER CURB INLET EXISTING STORM SEWER AERA INLET CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. CITY ENGINEER DATE DATE DATE DATE DATE STORMWATER UTILITY PARKS & RECREATION TRAFFIC ENGINEER DATE APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: WATER & WASTEWATER UTILITY CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL ENVIRONMENTAL PLANNER EXISTING CURB AND GUTTER TO REMAIN EXISTING PARKING TO REMAIN EXISTING SIDEWALK TO REMAIN EXISTING BUILDING TO REMAIN EXISTING CONCRETE PAN TO REMAIN EXISTING PEDESTRIAN CROSSWALK TO REMAIN EXISTING SITE LIGHT TO REMAIN EXISTING CURB CUT TO REMAIN EXISTING TREE TO REMAIN EXISTING UTILITY BOX TO REMAIN (SEE UTILITY PLAN FOR TYPE) EXISTING MANHOLE TO REMAIN (SEE UTILITY PLAN FOR TYPE) EXISTING CLEANOUT TO REMAIN (SEE UTILITY PLAN FOR TYPE) EXISTING INLET TO REMAIN (SEE UTILITY PLAN FOR TYPE) EXISTING FIRE HYDRANT TO REMAIN EXISTING RAILROAD TRACKS 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 46 47 48 49 50 51 52 53 54 55 56 45 PROPOSED MODIFIED CURB CUT PROPOSED 119,000 SF KING SOOPERS MARKETPLACE STORE; REF. ARCH. PLANS PROPOSED MECHANICAL ENCLOSURE AREA; REF. ARCH. PLANS PROPOSED CONCRETE LOADING DOCK; REF. ARCH. PLANS PROPOSED SCREEN WALL AT MECHANICAL UNITS; REF. ARCH. PLANS PROPOSED EGRESS LANDING WITH STAIRS OR RAMP; REF. ARCH. PLANS PROPOSED KING SOOPERS TRANSFORMER; REF. UTILITY PLAN PROPOSED VESTIBULE; REF. ARCH. PLANS PROPOSED OUTDOOR SALES AREA; REF. ARCH. PLANS PROPOSED TRASH ENCLOSURE PROPOSED MASONRY SCREEN WALL AT TRUCK DOCK; REF. ARCH. PLANS PROPOSED FIRE HYDRANT; REF. UTILITY PLAN PROPOSED MONUMENT SIGN; REF. SITE DETAILS, SHEET 9 PROPOSED CART CORRAL (TYP. 7) PROPOSED BOLLARD; REF. SITE DETAILS PROPOSED CONCRETE SIDEWALK (SIZE AS SHOWN ON HORIZONTAL CONTROL PROPOSED ASPHALT PAVING MILL AND OVERLAY PROPOSED ADA ACCESSIBLE RAMP WITH DETECTABLE WARNINGS; PROPOSED PHARMACY DRIVE THRU CANOPY AND DRIVE LANES; REF. ARCH. PLANS PROPOSED TRASH COMPACTOR; REF. ARCH. PLANS PROPOSED CONCRETE CURB AND GUTTER; REF. SITE DETAILS PROPOSED FULL DEPTH ASPHALT PAVING PROPOSED 9.5'x20' 60-DEGREE "ANGLED" PARKING STALL (TYP.); PROPOSED ADA PARKING STALL WITH PAINTED ACCESS AISLE AND SIGNAGE PROPOSED PARKING STRIPING; REF. SIGNAGE & STRIPING PLAN PROPOSED STOP BAR AND TRAFFIC DIRECTIONAL FLOW ARROW; REF. SITE DETAILS PROPOSED CROSSWALK; REF. SITE DETAILS PROPOSED R1-1 STOP SIGN; REF. SITE DETAILS PROPOSED BICYCLE RACK; REF. SITE DETAILS PROPOSED LANDSCAPING; REF. LANDSCAPE PLANS PROPOSED SITE LIGHT; REF. PHOTOMETRIC PLAN PROPOSED OUTDOOR SEATING AREA; REF. ARCH. PLANS PROPOSED 8'x15' 0-DEGREE "HEAD-IN" PARKING STALL (TYP.); PROPOSED AREA INLET; REF. UTILITY PLAN PROPOSED CURB INLET; REF. UTILITY PLAN PROPOSED LANDSCAPE PLANTER; REF. LANDSCAPE PLANS PROPOSED MANHOLE; REF. UTILITY PLAN FOR TYPE PROPOSED 9'x19' 90-DEGREE "HEAD-IN" PARKING STALL (TYP.); EXISTING 3 RAIL FENCE PROPOSED BUS PULL-OUT PROPOSED GREASE INTERCEPTOR EASEMENT SCHEDULE PROPOSED FIRE HYDRANT PROPOSED MANHOLE COVER PROPOSED INLET CART CORRAL (APPROXIMATE LOCATION) PARKING COUNT EXISTING EASEMENT BOUNDARY LINE TO BE REMOVED PROPOSED EASEMENT BOUNDARY LINE PROPOSED SITE LIGHTING PROPOSED SIGN 1 PARKING CALCULATIONS: STANDARD SPACE SITE DATA TABLE SITE AREA: 487,410 SF 119,000 SF F.A.R.: (KING SOOPERS BUILDING): HANDICAP SPACE TOTAL KING SOOPERS SHARED 367 22 20 0 394 60 LANDSCAPING: EXISTING FUELING TO REMAIN: 3,050 SF (11.19 ACRES) F.A.R.: (EXISTING FUELING TO REMAIN): F.A.R.: (EXISTING RETAIL TO REMAIN): 0.2440 0.0063 0.0113 TOTAL BLDG AREA: 127,550 SF BUILDING AREA: KING SOOPERS STORE: BICYCLE PARKING: 21 (1/20 SPACES) 22 (TWO RACKS) (SEE LANDSCAPE PLAN FOR DETAILS) (SEE LANDSCAPE PLAN FOR DETAILS) COMPACT SPACE 0 38 EXISTING RETAIL TO REMAIN: 5,500 SF F.A.R.: (TOTAL): 0.2616 (24.41% OF SITE) (0.63% OF SITE) (1.13% OF SITE) (26.17% OF SITE) 127,550 SF HARDSCAPE (DRIVEWAY, PARKING SIDEWALK, ETC.): 306,542 SF TOTAL SITE COVERAGE 487,410 SF SITE COVERAGE: BUILDINGS: LANDSCAPE/OPEN AREA: 43,400 SF (26.17% OF SITE) (62.89% OF SITE) (8.90% OF SITE) (100.00% OF SITE) CART CORRALS 7 0 ZONING: GENERAL COMMERCIAL GENERAL COMMERCIAL EXISTING PROPOSED MAXIMUM BUILDING HEIGHT: 35'-4" R.O.W. DEDICATION: 9,918 SF (2.04% OF SITE) EXISTING 6' UTILITY EASEMENT; REF. PLAT EXISTING 15' UTILITY EASEMENT; REF. PLAT EXISTING 20' UTILITY EASEMENT; REF. PLAT EXISTING 40' UTILITY EASEMENT; REF. PLAT EXISTING 10' DRAINAGE EASEMENT; REF. PLAT EXISTING TRAFFIC EASEMENT TO BE VACATED; REF. PLAT EXISTING SHARED PARKING EASEMENT; REF. PLAT EXISTING 40' UNDERGROUND UTILITY EASEMENT; REF. PLAT PROPOSED 20' WATER EASEMENT; REF. PLAT PROPOSED UTILITY EASEMENT; REF. PLAT PROPOSED TRAFFIC EASEMENT; REF. PLAT EXISTING 6' GAS AND POWER EASEMENT; REF. PLAT PLAN); REF. SITE DETAILS REF. SITE DETAILS REF. SIGNAGE & STRIPING PLAN (TYP. 21); REF. SITE DETAILS REF. SIGNAGE & STRIPING PLAN REF. SIGNAGE & STRIPING PLAN S SS SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 12' 'STM 12''STM 12''STM 15''STM 15''STM 15''STM 15''STM 15''ST M 15''STM 12''STM 24''STM 24''STM 24''STM 24''STM 24''STM 24''STM 12''STM 15''STM 15''STM 15''STM 15''STM 15''STM 24''STM 24''STM 24''STM 12''STM 18''STM 18' 'STM 18''STM UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT G G G G G G G G G UT UT UT UT UT UT UT UT G G G G G G G UT UT UT UT G G G G G G G X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X G X X G G G G G G G G G G G UT UT UT X X X X X X X X X X X X X X X X X X X X X X SS E IR IR IR EVT ECB GM IR CO IR E E E E TL TL TV RI WV SS WV WV SD CO EM SS WM WV GM D Y H D Y H SD E IR WECB GM ECB D Y H WV D Y H WV ECB EM E TL SS GM WM IR CO TL CO SS EXISTING BUILDING TO REMAIN ONE STORY BUILDING ONE STORY BUILDING TO REMAIN DRAKE ROAD 100' RIGHT OF WAY S. COLLEGE AVE. R.O.W. WIDTH VARIES SD 12''STM 18''STM 18''STM 18''STM 18''STM SS SS SS S D CO SS SS SS SS SS SS SS UE UE UE UE UE UE WV W WV W SD WV WV WV SS 3 28 10 36 10 30 10 36 40 36 1 1 34 35 45 49 45 40 27 1 28 57 47 43 43 32 31 43 10 35 44 20 48 35 43 34 1 27 27 29 1 1 28 29 27 57 56 32 13 16 29 21 27 26 47 52 51 59 46 35 47 48 44 52 45 31 29 52 55 58 50 12 21 55 58 52 27 37 59 49 51 50 49 44 50 59 34 43 43 34 58 40 55 35 34 40 34 44 37 35 34 43 27 34 39 38 52 54 54 10 10 10 43 1 20 43 10 10 10 10 3 32 10 34 40 44 27 52 43 34 35 35 35 35 35 35 35 35 35 35 35 35 35 40 34 43 31 27 52 43 34 43 34 24 9 40 34 43 10 40 34 34 43 34 36 31 4 19 4 27 55 49 43 58 34 50 43 34 52 43 43 40 72 34 14 30 1 3 31 31 32 15 1 30 17 4 14 7 8 10 3 1 10 12 8 1 3 34 49 59 59 52 43 10 34 40 61 7 8 6 5 22 1 3 26 10 10 10 34 12 43 34 59 34 21 36 20 26 1 12 16 22 5 8 6 1 1 7 13 3 2 31 51 52 3 13 10 10 1 1 8 18 44 56 56 11 21 23 23 23 15 24 53 25 12 34 25 28 53 25 32 28 28 LOT 4 K-MART PLAZA LOT 2 EXTENTION OF K-MART PLAZA LOT 2 K-MART PLAZA LOT 1 K-MART PLAZA 10 43 36 # 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 O www.gallowayUS.com C 2016. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By: H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_03-Demo.dwg - Rob Gordon - 2015-04-16 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT King Soopers Marketplace 65 Tejon Street Denver, CO 80223 Phone (303) 778-3053 Fax (303) 871-9262 BASISKSS000146 OF BEARING THE EAST LINE OF THE SOUTHEAST QUARTER OF SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PM. BEING MONUMENTED AT THE NORTH END BY A 2-1/2" ALUMINUM CAP, AND AT THE SOUTH END BY A 3" ALUMINUM CAP, IS ASSUMED TO BEAR N 00°18'00" W, WITH A DISTANCE OF 2640.61 FEET BETWEEN SAID MONUMENTS. BENCHMARK NATIONAL GEODETIC SURVEY BENCHMARK "C322 RESET 1959" NAVD 88 ELEVATION: 4989.40 A STANDARD 3 1/2 INCH U.S. CONSTRUCTION AND GEODETIC SURVEY BRASS BENCHMARK DISK SET IN THE TOP OF A CONCRETE WALL ON THE NORTH SIDE OF SPRING CREEK. LOCATED 47 FEET WEST OF THE CENTERLINE OF COLLEGE AVENUE (AKA U.S. HIGHWAY 287) AND 3,566 FEET NORTH OF THE CENTERLINE OF DRAKE STREET. RDG PJD NOVEMBER 2016 EXISTING CONDITIONS & DEMOLITION PLAN 3 SCALE: 1"=50' 0 10 20 50 SCHEDULE PROPERTY BOUNDARY LINE ADJACENT PROPERTY BOUNDARY LINE EXISTING TO REMAIN EASEMENT BOUNDARY LINE EXISTING TO BE REMOVED SAWCUT LINE CONTRACTOR TO REFER TO GEOTECHNICAL REPORT (PREPARED BY KUMAR & ASSOCIATES, REPORT No. XX-X-XXX) FOR PAVING, SUBGRADE AND COMPACTION RECOMMENDATIONS. SEE GRADING AND PAVING PLANS FOR DETAILED INFORMATION ON FINAL GRADES AND PAVING CONTRACTOR TO REFER TO THE LANDSCAPE AND IRRIGATION PLANS AND TREE PROTECTION NOTES FOR LOCATION OF EXISTING TREES, TREE PRESERVATION DETAILS, STORAGE OF EQUIPMENT UNDER TREES, PRUNING AND EXISTING IRRIGATION. DEMOLITION NOTES 1. ALL DEMOLITION TO BE IN ACCORDANCE WITH STATE, LOCAL, AND FEDERAL REQUIREMENTS. 2. CONTRACTOR TO VERIFY ALL UTILITY SERVICE LOCATIONS AND EXISTING SITE CONDITIONS PRIOR TO PROCEEDING. ANY SITE CONDITIONS THAT ARE NOT AS SHOWN MUST BE REPORTED TO THE COMPANY REPRESENTATIVE PRIOR TO BID. 3. CONTRACTOR TO REMOVE OR RELOCATE EXISTING UTILITIES PER UTILITY COMPANY REQUIREMENTS. 4. CONTRACTOR TO ERECT BARRIERS, FENCES, GUARDRAILS, ENCLOSURES, ETC. TO PROTECT SITE. THE PROTECTION PLAN MUST BE REVIEWED BY THE COMPANY REPRESENTATIVE PRIOR TO PROCEEDING. 5. COMPANY REPRESENTATIVE WILL DETERMINE WHEN CONDITIONS ARE SUITABLE TO COMMENCE WORK. CONTRACTOR TO VERIFY AREAS TO BE DEMOLISHED ARE UNOCCUPIED AND NOT IN USE. 6. REMOVE ALL STRUCTURES ALONG WITH ALL ELECTRICAL, MECHANICAL AND OTHER APPURTENANCES. 7. ABANDON BOTTOM SLABS IN PLACE EXCEPT IN THE FOLLOWING INSTANCES: A. IF ANY POINT OF THE SLAB IS LESS THAN 4' BELOW FINISH GRADE B. IF THE SLAB INTERFERES WITH CONSTRUCTION OF OTHER FACILITIES. 8. DISPOSE OF AND TRANSPORT DEBRIS TO AREA OBTAINED BY CONTRACTOR. DO NOT STORE OR BURN MATERIALS ON SITE. 9. REMOVE ALL ASPHALT, TREES, POSTS AND OTHER IMPROVEMENTS UNLESS THE ITEM IS SPECIFIED TO REMAIN. 10. FILL AND COMPACT BASEMENTS, CESSPOOLS, AND OTHER LARGE EXCAVATED AREAS WITH CLEAN FILL SUITABLE TO THE COMPANY REPRESENTATIVE AND IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. GRADE TO MATCH EXISTING OR PROPOSED FINISH GRADE. 11. SEE PROJECT SPECIFICATIONS FOR EXISTING ITEMS TO BE SALVAGED AND OTHER REQUIREMENTS PERTAINING TO THE SALVAGE THEREOF. 12. REMOVE ALL EXISTING FOUNDATION WALLS AND FOOTINGS COMPLETELY UNLESS OTHERWISE NOTED OR SPECIFIED. 13. ALL UNDERGROUND STORM SEWER, WATER, AND SANITARY SEWER MAIN LOCATIONS ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. 14. ALL UNDERGROUND GAS AND ELECTRIC UTILITY INFORMATION SHOWN IS BASED ON MAPS PROVIDED BY UTILITY COMPANY AND ARE TO BE CONSIDERED AS AN APPROXIMATE LOCATION ONLY BASED ON SAID MAPS. 15. CONTRACTOR TO OBTAIN ALL PERMITS AND LICENSES REQUIRED FOR DEMOLITION OF WORK SHOWN. EXISTING WATER LINE EXISTING GAS LINE EXISTING UNDERGROUND ELECTRICAL TO BE REMOVED EXISTING SANITARY SEWER UE UG W SS UTTELEPHONE EXISTING UNDERGROUND STM EXISTING STORM SEWER FO EXISTING FIBER OPTIC LINE EXISTING STORM SEWER (TO BE REMOVED) GEOTECHNICAL NOTE LANDSCAPE AND IRRIGATION NOTE CONTRACTOR TO REFER TO THE ASBESTOS SURVEY PREPARED BY KUMAR & ASSOCIATES (REPORT No. xx-x-xxx) FOR THE RETAIL BUILDING BEING DEMOLISHED FOR DETAILS ON ASBESTOS CONTAINING MATERIALS AND DISPOSAL PARAMETERS. ENVIRONMENTAL NOTE 1 EXISTING SANITARY SEWER MANHOLE EXISTING GAS METER EXISTING ELECTRICAL MANHOLE EXISTING WATER VALVE EXISTING FENCE EXISTING TRAIN TRACTS EXISTING FIRE HYDRANT EXISTING ELECTRICAL BOX LEGEND X X X X EXISTING ELECTRICAL METER/RISER EXISTING WATER METER EXISTING LIGHT POLE EXISTING TELEPHONE MANHOLE EXISTING TELEPHONE RISER EXISTING IRRIGATION BOX EM SECTION LINE WV WM SS CO D Y H IR ECB TL E EVT GM RI E EXISTING SANITARY SEWER CLEANOUT EXISTING ELECTRICAL CABINET EXISTING ELECTRICAL VAULT EXISTING EXISTING TREE TO REMAIN EXISTING SIGN EXISTING STORM SEWER CURB INLET EXISTING STORM SEWER AERA INLET STM CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. CITY ENGINEER DATE DATE DATE DATE DATE STORMWATER UTILITY PARKS & RECREATION TRAFFIC ENGINEER DATE APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: WATER & WASTEWATER UTILITY CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL ENVIRONMENTAL PLANNER EXISTING CURB AND GUTTER TO REMAIN EXISTING PARKING TO REMAIN EXISTING SIDEWALK TO REMAIN EXISTING BUILDING TO REMAIN EXISTING CONCRETE PAN TO REMAIN EXISTING PEDESTRIAN CROSSWALK TO REMAIN EXISTING SITE LIGHT TO REMAIN EXISTING CURB CUT TO REMAIN EXISTING TREE TO REMAIN EXISTING CABLE TELEVISION UTILITY BOX TO REMAIN EXISTING UNDERGROUND ELECTRICAL TO REMAIN EXISTING ELECTRICAL CABINET TO REMAIN EXISTING WATER MANHOLE TO REMAIN EXISTING ELECTRICAL MANHOLE TO REMAIN EXISTING ELECTRICAL VAULT TO REMAIN EXISTING GAS METER TO REMAIN EXISTING GAS TO REMAIN EXISTING TELEPHONE MANHOLE TO REMAIN EXISTING TELEPHONE RISER TO REMAIN EXISTING FENCE TO REMAIN EXISTING SANITARY SEWER MANHOLE TO REMAIN EXISTING STORM SEWER TO REMAIN EXISTING STORM SEWER INLET TO REMAIN EXISTING STORM SEWER MANHOLE TO REMAIN EXISTING IRRIGATION BOX TO REMAIN EXISTING WATER TO REMAIN EXISTING WATER VALVE TO REMAIN EXISTING WATER METER TO REMAIN EXISTING CURB AND GUTTER TO BE REMOVED EXISTING PARKING STRIPING TO BE REMOVED EXISTING SIDEWALK TO BE REMOVED EXISTING BUILDING TO BE REMOVED EXISTING CONCRETE PAN TO BE REMOVED EXISTING PEDESTRIAN CROSSWALK TO BE REMOVED EXISTING SITE LIGHT TO BE REMOVED/RELOCATED EXISTING ASPALT PAVEMENT TO BE REMOVED EXISTING TREE TO BE REMOVED EXISTING UNDERGROUND ELECTRICAL TO BE REMOVED EXISTING ELECTRICAL BOX TO BE REMOVED/REPLACED EXISTING ELECTRICAL METER TO BE REMOVED EXISTING GAS METER TO BE REMOVED EXISTING UNDERGROUND TELEPHONE TO BE REMOVED EXISTING SANITARY SEWER CLEANOUT TO BE REMOVED EXISTING SANITARY SEWER TO BE REMOVED EXISTING SANITARY SEWER MANHOLE TO BE REMOVED EXISTING STORM SEWER TO BE REMOVED EXISTING IRRIGATION BOX TO BE REMOVED EXISTING WATER TO BE REMOVED EXISTING WATER METER TO BE REMOVED EXISTING FIRE HYDRANT TO BE REMOVED EXISTING RAILROAD TRACKS EXISTING ELECTRICAL BOX TO REMAIN EXISTING ELECTRICAL METER TO REMAIN EXISTING UNDERGROUND TELEPHONE TO REMAIN EXISTING SANITARY SEWER TO REMAIN EXISTING STORM SEWER INLET TO BE REMOVED EXISTING WATER VALVE TO BE REMOVED 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 EXISTING ASPALT PAVEMENT TO ROTO MILLED 2" 45 EXISTING FENCE TO REMAIN EXISTING CONCRETE TO BE REMOVED UEELECTRICAL EXISTING UNDERGROUND SS EXISTING SANITARY SEWER TO BE REMOVED EMREMOVED EXISTING ELECTRICAL METER/RISER TO BE ECB EXISTING ELECTRICAL CABINET TO BE REMOVED EXISTING WATER VALVE TO BE REMOVED EXISTING FIRE HYDRANT TO BE REMOVED EXISTING WATER METER TO BE REMOVED WV WM D Y H EXISTING GAS METER TO BE REMOVED CO GM EXISTING SANITARY SEWER CLEANOUT TO BE REMOVED IR EXISTING IRRIGATION BOX TO BE REMOVED EXISTING EXISTING TREE TO BE REMOVED EXISTING SIGN TO BE REMOVED EXISTING STORM SEWER AERA INLET 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 6.0 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the Final Drainage and Erosion Control Reports for Timbervine dated October 15, 2014 by Galloway and Company, Inc., shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by Larimer County. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: PROJECT DATUM: BENCHMARK: NATIONAL GEODETIC SURVEY BENCHMARK "C322 RESET 1959" NAVD 88 ELEVATION: 4989.40 A STANDARD 3 1/2 INCH U.S. CONSTRUCTION AND GEODETIC SURVEY BRASS BENCHMARK DISK SET IN THE TOP OF A CONCRETE WALL ON THE NORTH SIDE OF SPRING CREEK. LOCATED 47 FEET WEST OF THE CENTERLINE OF COLLEGE AVENUE (AKA U.S. HIGHWAY 287) AND 3,566 FEET NORTH OF THE CENTERLINE OF DRAKE STREET. 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: Approved Variances are listed as follows: CONSTRUCTION NOTES A. GRADING AND EROSION CONTROL NOTES 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. B. STREET IMPROVEMENT NOTES 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. TRAFFIC SIGNING AND PAVEMENT MARKING CONSTRUCTION NOTES 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. STORM DRAINAGE NOTE 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. All recommendations of the Final Drainage and Erosion Control Reports for Kmart Plaza Redevelopment dated November XX, 2016 by Galloway and Company, shall be followed and implemented. 3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. CITY ENGINEER DATE DATE DATE DATE DATE STORMWATER UTILITY PARKS & RECREATION TRAFFIC ENGINEER DATE APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: WATER & WASTEWATER UTILITY CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL ENVIRONMENTAL PLANNER FAX: (303) 770-3636 ATTN: PHIL DALRYMPLE, PE GALLOWAY & COMPANY, INC. 6162 S. WILLOW DRIVE, SUITE 320 GREENWOOD VILLAGE, COLORADO 80111 TEL: (303) 770-8884 FAX: (303) 770-3636 ATTN: KERRI LILJEGREN, RLA, LEED AP CIVIL ENGINEER/ENTITLEMENT CONSULTANT SITE MAP SCALE: 1"=250' CR ARCHITECTURE & DESIGN 1675 BROADWAY, SUITE 2480 DENVER, CO 80202 TEL: (303) 863-8100 CONTACT: BAYLOR BLAND SITE DRAKE ROAD S. COLLEGE AVE. LEGAL DESCRIPTION A PARCEL OF LAND BEING A REPLAT OF LOTS 1, 2, AND 4, OF K-MART PLAZA, AND ALL OF LOT 2 OF THE EXTENSION OF K-MART PLAZAIN THE SOUTHEAST QUARTER (SE 1/4) OF SECTION TWENTY-THREE (23), TOWNSHIP SEVEN NORTH (T.7N.), RANGE SIXTY-NINE WEST (R.69W.), SIXTH PRINCIPAL MERIDIAN (6TH P.M.), CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO WHICH CONTAINS 11.189 ACRES MORE OR LESS. BASIS OF BEARING THE EAST LINE OF THE SOUTHEAST QUARTER OF SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PM. BEING MONUMENTED AT THE NORTH END BY A 2-1/2" ALUMINUM CAP, AND AT THE SOUTH END BY A 3" ALUMINUM CAP, IS ASSUMED TO BEAR N 00°18'00" W, WITH A DISTANCE OF 2640.61 FEET BETWEEN SAID MONUMENTS. BENCHMARK NATIONAL GEODETIC SURVEY BENCHMARK "C322 RESET 1959" NAVD 88 ELEVATION: 4989.40 A STANDARD 3 1/2 INCH U.S. CONSTRUCTION AND GEODETIC SURVEY BRASS BENCHMARK DISK SET IN THE TOP OF A CONCRETE WALL ON THE NORTH SIDE OF SPRING CREEK. LOCATED 47 FEET WEST OF THE CENTERLINE OF COLLEGE AVENUE (AKA U.S. HIGHWAY 287) AND 3,566 FEET NORTH OF THE CENTERLINE OF DRAKE STREET. CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. RDG PJD NOVEMBER 2016 COVER SHETT 1 UTILITY CONTACT LIST: * UTILITY COMPANY * ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. PHONE NUMBER GAS XCEL ENERGY STEPHANIE RICH (970) 225-7828 ELECTRIC CITY OF FORT COLLINS LIGHT & POWER DOUG MARTINE (970) 224-6152 CABLE XFINITY DON KAPPERMAN (970) 567-0425 TELECOM CENTURYLINK WILLIAM JOHNSON (970) 377-6401 WATER ELCO MIKE SCHEID (970) 493-2044 WASTEWATER BOXELDER SANITATION DISTRICT KAREN REYNOLDS (970) 498-0604 STORMWATER CITY OF FORT COLLINS UTILITIES GLEN SCHLUETER (970) 221-6700 PROJECT TEAM TRAFFIC ENGINEER KIMLEY-HORN 4582 S. ULSTER STREET, SUITE 1500 DENVER, COLORADO 80237 TEL: (303) 228-2304 CONTACT: CURTIS ROWE, P.E. PTOE CONTACT THESE PLANS HAVE BEEN REVIEWED BY THE CITY OF FORT COLLINS FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BY THE REVIEWING DEPARTMENT, THE CITY OF FORT COLLINS ENGINEER, OR THE CITY OF FORT COLLINS FOR ACCURACY AND CORRECTNESS OF THE CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT QUANTITIES OF ITEMS ON THE PLANS ARE THE FINAL QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED FOR ANY REASON AS ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE CITY OF FORT COLLINS FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE CONSTRUCTION PHASE. DISCLAIMER STATEMENT I HEREBY AFFIRM THAT THESE FINAL CONSTRUCTION PLANS WERE PREPARED UNDER MY DIRECT SUPERVISION, IN ACCORDANCE WITH ALL APPLICABLE CITY OF FORT COLLINS AND STATE OF COLORADO STANDARDS AND STATUTES, RESPECTIVELY; AND THAT I AM FULLY RESPONSIBLE FOR THE ACCURACY OF ALL DESIGN. REVISIONS, AND RECORD CONDITIONS THAT I HAVE NOTED ON THESE PLANS. CERTIFICATION STATEMENT CITY ENGINEER DATE DATE DATE DATE DATE STORMWATER UTILITY PARKS & RECREATION TRAFFIC ENGINEER DATE APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: WATER & WASTEWATER UTILITY CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL ENVIRONMENTAL PLANNER