HomeMy WebLinkAboutKING SOOPERS #146, MIDTOWN GARDENS MARKETPLACE (FORMERLY KMART REDEVELOPMENT ) - PDP - PDP160043 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORTW W
W W W W W W W W W W W W W W
W W W W W W W W W W W W W
W
W W W W W
W W W W W
W W
C
O
CO
E
UE UE
UE
UE
UE
UE UE
UE
UE UE UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE UE
UE
UE
UE
UE UE
UE
UE
UE UE
UE
UE
UE
UE
SS SS
SS SS SS SS SS
SS
SS SS SS
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
STM STM
STM STM
STM
STM
STM STM STM STM
STM STM
STM STM STM
STM
CO
CO
12''STM 12''STM 12''STM
15''STM 15''STM 15''STM
15''S
TM 15''STM 15''STM
12''STM
24''STM 24''STM 24''STM
24''STM
24''STM 24''ST
M
15''STM 15''STM
15''STM 15''STM 15''STM
24''STM 24''STM 24''STM
18''STM 1
8''STM 18''STM
X
X
X
X
X
X X X
X X X
X X X X X X X X
X
X X X X
X X X X X X X X
X X X
X
X
X
X
IR
IR
IR
GM
SD SD
GM
IR
EXISTING BUILDING
TO REMAIN
ONE STORY BUILDING
ONE STORY BUILDING
TO REMAIN
DRAKE ROAD
100' RIGHT OF WAY
S. COLLEGE AVE.
R.O.W. WIDTH VARIES
SD
18''STM 18''STM 18''STM 18''STM
SD
1
Rx
DRIVE
THRU
GROCERY
PICK UP
2
3
4
MARKETPLACE
119,000 SF
STM STM
STM STM
STM STM
STM STM
STM
STM
STM STM STM STM
STM STM
STM STM
STM
STM
STM STM
STM
STM
STM
STM
STM
STM
18"STM
18"STM
18"STM
18"STM
18"STM 18"STM
18"STM
18"STM 18"STM
18"STM
18"STM
18"STM
18"STM
18"STM
18"STM
18"STM
18"STM
18"STM
18"STM
18"STM
LOT 1
487,410 SF (11.189 AC)
RG-12
RG-11
RG-1
RG-2
RG-3
RG-4
RG-5/6
RG-7
RG-8
RG-9
RG-10
#
6162 S. Willow Drive, Suite 320
Greenwood Village, CO 80111
303.770.8884 O
www.gallowayUS.com
C 2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\Temp\Herman\KSS146_LID EXHIBIT.dwg - Phil Dalrymple - 2015-04-16
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
King Soopers
Supermarket
65 Tejon Street
Denver, CO 80223
Phone (303) 778-3053
Fax (303) 871-9262
KSS000146
HHF
HHF
NOVEMBER 2016
LID EXHIBIT
1
SITE LEGEND
ADJACENT PROPERTY BOUNDARY LINE
PROPERTY BOUNDARY LINE
PROPOSED CURB & GUTTER
EXISTING CURB & GUTTER TO REMAIN
PROPOSED INLET
EASEMENT BOUNDARY LINE
STREET LIGHT
EXISTING TO BE REMOVED
GRADING LEGEND
EXISTING STORM SEWER
PROPOSED STORM SEWER
STS
45 PROPOSED CONTOUR
5245 EXISTING CONTOUR
STS
STS PROPOSED STORM SEWER (LESS THAN 12")
SCALE: 1"=50'
0 10 20 50
DRAINAGE LEGEND
PROPOSED RAIN GARDEN TRIBUTARY AREA
FLOW ARROW
PROPOSED RAIN GARDEN AND FLAT AREA
12'
'STM 12''STM 12''STM
15''STM 15''STM 15''STM
15''STM 15'
'STM 15''STM
12''STM
24''STM 24''STM 24''STM
24''STM
24''STM 24''STM
12''STM
15'
'STM 15''STM
15''STM 15''STM 15''STM
24''STM 24''STM 24''STM
18''STM 18''
STM 18''STM
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT
UT UT
UT
UT
UT
G G G
G
G G
G G
G
UT
UT
UT UT UT UT UT UT
G G G G
G
G
G
UT
UT
UT
UT
G
G G
G G G
G
X
X
X
X
X
X
X X
X X X
X X X X X X X X
X
X X X X
X X X X X X X X
X X X
X
X
X X
G
X X
G
G
G G G
G
G G
G G
G
UT
UT
UT
X
X X X X X
X
X X
X
X X X X
X X
X X X X X X
SS
E
IR
IR
IR
EVT
ECB
GM
IR
CO
N0°22'28"E 2640.62'
BASIS OF BEARINGS
IR
E
E
E
E
TL
TL
TV
RI
WV
SS
SD
CO
EM
SS
WM WV
GM
D
Y
H
D
Y
H
SD
E
IR
WECB GM
ECB
D
Y
H
WV
D
Y
H
WV
ECB
EM E
TL
SS
GM
WM
IR
CO
TL
CO
SS
EXISTING BUILDING
TO REMAIN
ONE STORY BUILDING
ONE STORY BUILDING
TO REMAIN
DRAKE ROAD
100' RIGHT OF WAY
S. COLLEGE AVE.
R.O.W. WIDTH VARIES
SD
18''STM 18''STM 18''STM 18''STM
SS SS
S
D
CO
SS SS SS SS SS SS SS
UE
UE
UE
UE
UE
UE
WV
W
SD
WV
WV
WV
SS
1
RxDRIVE
THRU
GROCERY
PICK UP
2
3
4
MARKETPLACE
119,000 SF
STM STM
STM STM
STM STM
STM STM
STM
STM
STM STM STM STM
STM STM
STM STM
STM
W
STM
STM STM
STM
STM
STM
STM
STM
STM
18"STM
18"STM
18"STM
18"STM
18"STM 18"STM
18"STM
18"STM 18"STM
18"STM
18"STM
18"STM
18"STM
18"STM
18"STM
18"STM
18"STM
18"STM
18"STM
18"STM
8''SS 8''
SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
8''SS 8'
'SS 8''SS 8''SS 8''SS 8''SS
LOT 1
487,410 SF (11.189 AC)
SINGLE TYPE 13
COMBINATION
INLET
A-10
0.67
0.90
1.00
OS-1
0.15
0.85
1.00
A-1
0.63
0.85
1.00
A-2
0.26
0.86
1.00
A-3
0.19
0.91
1.00
A-4
0.75
0.90
1.00
A-6
0.30
0.78
0.97
A-8
0.37
0.81
1.00
A-7
0.92
0.90
1.00
A-9
0.42
0.90
1.00
A-11
0.11
0.95
1.00
A-12
0.32
0.74
0.92
A-13
0.45
0.87
1.00
B-1
1.11
0.88
1.00
B-2
1.31
0.89
1.00
E-1
0.15
0.85
1.00
D-1
0.66
0.65
0.82
B-3
1.38
0.87
1.00
C-1
0.74
0.92
1.00
C-2
0.29
0.92
1.00
SINGLE TYPE 13
COMBINATION
INLET
5' TYPE R
INLET
5' TYPE R
INLET
5' TYPE R
INLET
5' TYPE R
INLET
5' TYPE R
INLET
5' TYPE R
INLET
5' TYPE R
INLET
5' TYPE R
INLET
TYPE 13
AREA INLET
TYPE 13
AREA
INLET
TYPE 13
AREA
INLET
EXISTING
INLET
TO BE
REMOVED
EXISTING
INLET
TO BE
REMOVED
EXISTING
INLET
TO BE
REMOVED
EXISTING
INLET
TO BE
REMOVED
EXISTING INLET
TO BE REMOVED &
REPLACED W/ 4'
MANHOLE
EXISTING
INLET
TO BE
REMOVED &
REPLACED W/
4' MANHOLE
EXISTING INLET
TO BE REMOVED
& REPLACED W/ 4'
MANHOLE
#
6162 S. Willow Drive, Suite 320
Greenwood Village, CO 80111
303.770.8884 O
www.gallowayUS.com
C 2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_11-Drainage.dwg - Phil Dalrymple - 2015-04-16
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
King Soopers
Marketplace
65 Tejon Street
Denver, CO 80223
Phone (303) 778-3053
Fax (303) 871-9262
KSS000146
SITE LEGEND
ADJACENT PROPERTY BOUNDARY LINE
PROPERTY BOUNDARY LINE
PROPOSED CURB & GUTTER
EXISTING CURB & GUTTER TO REMAIN
PROPOSED INLET
EASEMENT BOUNDARY LINE
STREET LIGHT
EXISTING TO BE REMOVED
GRADING LEGEND
EXISTING STORM SEWER
PROPOSED STORM SEWER
STS
45 PROPOSED CONTOUR
5245 EXISTING CONTOUR
STS
STS PROPOSED STORM SEWER (LESS THAN 12")
DRAINAGE LEGEND
PROPOSED BASIN BOUNDARY LINE
DESIGN POINT
BASIN AREA IN ACRES
100-YEAR RUNOFF COEFFICIENT
BASIN DESIGNATION
A 2-YEAR RUNOFF COEFFICIENT
0.00
0.00
0.00
FLOW ARROW
CITY OF FORT COLLINS DRAINAGE NOTES
1. ALL STREET, SANITARY SEWER, STORM SEWER AND WATER CONSTRUCTION SHALL CONFORM TO CITY STANDARDS
AND SPECIFICATIONS CURRENT AT THE DATE OF EXECUTION OF THE DEVELOPMENT AGREEMENT PERTAINING TO
THIS DEVELOPMENT. ANY CONSTRUCTION OCCURRING THREE YEARS AFTER THE EXECUTION OF THE
DEVELOPMENT AGREEMENT SHALL REQUIRE RE-EXAMINATION OF THE PLANS BY THE DIRECTOR WHO MAY
REQUIRE THAT THEY BE MADE TO CONFORM TO STANDARDS AND SPECIFICATIONS CURRENT AT THAT TIME.
2. THE TYPE, SIZE, LOCATION, AND NUMBER OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE AS SHOWN ON THE
DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE AND LOCATION OF ALL
UNDERGROUND UTILITIES ALONG THE ROUTE OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR
SHALL BE RESPONSIBLE FOR LOCATING UNKNOWN UNDERGROUND UTILITIES.
3. THESE PLANS HAVE BEEN REVIEWED BY THE CITY FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BY
THE REVIEWING DEPARTMENT, THE CITY ENGINEER, OR THE CITY FOR ACCURACY OR CORRECTNESS OF THE CALCULATIONS.
FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT THE QUANTITIES OF THE ITEMS ON THE PLANS ARE THE FINAL
QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS ACCEPTANCE OF FINANCIAL
RESPONSIBILITY BY THE CITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE
CONSTRUCTION PHASE.
4. PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION, THE CONTRACTOR MUST GIVE THE CITY ENGINEERING
DEPARTMENT (970-221-6605) AND THE EROSION CONTROL INSPECTOR (970-221-6700) TWENTY-FOUR (24) HOURS
ADVANCE-NOTICE. INITIAL EROSION CONTROL MEASURES MUST BE INSTALLED AND A SITE INSPECTION BY THE EROSION
CONTROL INSPECTOR IS REQUIRED BEFORE COMMENCING CONSTRUCTION ACTIVITIES.
5. MAINTENANCE OF ONSITE DRAINAGE FACILITIES SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNERS.
6. ALL RECOMMENDATIONS OF THE FINAL DRAINAGE AND EROSION CONTROL STUDY FOR THIS DEVELOPMENT BY (ENGINEERING
FIRM) MUST BE MET.
7. PRIOR TO FINAL INSPECTION AND ACCEPTANCE BY THE CITY, CERTIFICATION OF THE DRAINAGE FACILITIES BY A COLORADO
REGISTERED PROFESSIONAL ENGINEER MUST BE SUBMITTED TO AND APPROVED BY THE CITY STORMWATER DEPARTMENT.
FOR COMMERCIAL AND MULTI-FAMILY DEVELOPMENTS, CERTIFICATION OF ALL DRAINAGE FACILITIES SHALL BE SUBMITTED TO
THE CITY STORMWATER DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF A CERTIFICATE OF OCCUPANCY.
INDIVIDUAL LOT CERTIFICATION, ELEVATION CERTIFICATION, OR FLOODPROOFING CERTIFICATION, AS SPECIFIED IN THE
DEVELOPMENT AGREEMENT, MUST BE SUBMITTED TO THE CITY STORMWATER DEPARTMENT AT LEAST TWO WEEKS PRIOR TO
THE RELEASE OF A CERTIFICATE OF OCCUPANCY FOR SUCH LOT.
8. IF DEWATERING IS USED TO INSTALL UTILITIES, AND DISCHARGE WILL BE INTO THE STREET, GUTTER, STORM SEWER,
CHANNEL, IRRIGATION DITCH, OR ANY WATERS OF THE STATE A STATE CONSTRUCTION DEWATERING INDUSTRIAL
WASTEWATER DISCHARGE PERMIT IS REQUIRED.
9. ALL LAND DISTURBING ACTIVITIES GREATER THAN OR EQUAL TO ONE ACRE MUST COMPLY WITH THE STATE OF COLORADO
PERMITTING PROCESS FOR STORMWATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITY. FOR MORE
INFORMATION CONTACT THE COLORADO DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT, WATER QUALITY CONTROL
DIVISION, AT 303-692-3500 OR REFER TO THE WEB SITE AT HTTP://WWW.CDPHE.STATE.CO.US/WQ/PERMITSUNIT/ .
10. BENCHMARK: NATIONAL GEODETIC SURVEY BENCHMARK "C322 RESET 1959"
NAVD 88 ELEVATION: 4989.40
A STANDARD 3 1/2 INCH U.S. CONSTRUCTION AND GEODETIC SURVEY BRASS BENCHMARK DISK SET IN THE TOP OF
A CONCRETE WALL ON THE NORTH SIDE OF SPRING CREEK. LOCATED 47 FEET WEST OF THE CENTERLINE OF
COLLEGE AVENUE (AKA U.S. HIGHWAY 287) AND 3,566 FEET NORTH OF THE CENTERLINE OF DRAKE STREET.
11. IF FILL OR DREDGED MATERIAL IS DISCHARGED INTO WATERS OF THE UNITED STATES, A USACE 404 PERMIT IS REQUIRED.
12. IF CONSTRUCTION AFFECTS ANY COLORADO HIGHWAY, A COLORADO DEPARTMENT OF TRANSPORTATION RIGHT-OF-WAY
PERMIT IS REQUIRED.
SCALE: 1"=50'
0 10 20 50
GENERAL DRAINAGE NOTES
1. NO BUILDING, STRUCTURE, OR FILL WILL BE PLACED IN THE DETENTION AREAS AND
CHANGES OR ALTERATIONS AFFECTING THE HYDRAULIC CHARACTERISTICS OF THE
DETENTION AREAS WILL BE MADE WITHOUT THE APPROVAL OF THE CITY ENGINEER.
2. MAINTENANCE AND OPERATION OF THE DETENTION AND WATER QUALITY AREAS IS THE
RESPONSIBILITY OF PROPERTY OWNER. IF OWNER FAILS IN THIS RESPONSIBILITY, THE
CITY HAS THE RIGHT TO ENTER THE PROPERTY, MAINTAIN THE DETENTION AREAS, AND BE
REIMBURSED FOR COSTS INCURRED.
3. DETENTION POND VOLUMES, ALL DRAINAGE APPURTENANCES, AND BASIN BOUNDARIES
SHALL BE VERIFIED. AS-BUILT DRAWINGS SHALL BE PREPARED BY A REGISTERED
PROFESSIONAL ENGINEER PRIOR TO ISSUANCE OF CERTIFICATE OF OCCUPANCY.
4. PERMISSION TO REPRODUCE THESE PLANS IS HEREBY GIVEN TO THE CITY OF LITTLETON
FOR CITY PURPOSES ASSOCIATED WITH PLAN REVIEW, APPROVAL, PERMITTING,
INSPECTION AND CONSTRUCTION OF THE WORK.
5. ALL PROPOSED CURB AND GUTTER FOR THE SITE SHALL BE 6" VERTICAL CURB AND
GUTTER W/ A 1' PAN.
Tributary Area tc | 2-Year tc | 100-Year
Q2 Q100
Sub-basin (acres) (min) (min) (cfs) (cfs)
OS-1 0.15 0.85 1.00 5.0 5.0 0.4 1.5
A-1 0.63 0.85 1.00 5.0 5.0 1.5 6.3
A-2 0.26 0.86 1.00 5.0 5.0 0.6 2.6
A-3 0.19 0.91 1.00 5.0 5.0 0.5 1.9
A-4 0.75 0.90 1.00 5.0 5.0 1.9 7.5
A-5 0.11 0.95 1.00 5.0 5.0 0.3 1.1
A-6 0.30 0.78 0.97 5.0 5.0 0.7 2.9
A-7 0.92 0.90 1.00 5.4 5.0 2.3 9.2
A-8 0.37 0.81 1.00 5.0 5.0 0.9 3.7
A-9 0.42 0.90 1.00 5.0 5.0 1.1 4.2
A-10 0.67 0.90 1.00 5.0 5.0 1.7 6.7
A-11 0.11 0.95 1.00 5.0 5.0 0.3 1.1
A-12 0.32 0.74 0.92 5.0 5.0 0.7 3.0
A-13 0.45 0.87 1.00 5.0 5.0 1.1 4.5
B-1 1.11 0.88 1.00 5.2 5.0 2.8 11.1
B-2 1.31 0.89 1.00 5.0 5.0 3.3 13.1
B-3 1.38 0.87 1.00 5.0 5.0 3.4 13.8
C-1 0.74 0.92 1.00 5.0 5.0 1.9 7.4
C-2 0.29 0.92 1.00 5.0 5.0 0.8 2.9
D-1 0.66 0.65 0.82 12.3 10.5 0.9 4.2
E-1 0.15 0.85 1.00 5.0 5.0 0.4 1.5
BASIN SUMMARY TABLE
C2 C
100
SITE
VICINITY MAP
NOT TO SCALE
RDG
PJD
NOVEMBER 2016
DRAINAGE PLAN
11
BASIS OF BEARING
THE EAST LINE OF THE SOUTHEAST QUARTER OF SECTION 23, TOWNSHIP 7 NORTH, RANGE 69
WEST OF THE 6TH PM. BEING MONUMENTED AT THE NORTH END BY A 2-1/2" ALUMINUM CAP, AND
AT THE SOUTH END BY A 3" ALUMINUM CAP, IS ASSUMED TO BEAR N 00°18'00" W, WITH A DISTANCE
OF 2640.61 FEET BETWEEN SAID MONUMENTS.
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED
BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE
EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED
AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS
OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY
DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT
IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE
HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING
UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE
METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO
CONSTRUCTION.
CITY ENGINEER DATE
DATE
DATE
DATE
DATE
STORMWATER UTILITY
PARKS & RECREATION
TRAFFIC ENGINEER
DATE
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
WATER & WASTEWATER UTILITY
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
ENVIRONMENTAL PLANNER