Loading...
HomeMy WebLinkAboutSPRINGER PLAZA - MJA/FDP - FDP160047 - SUBMITTAL DOCUMENTS - ROUND 1 - SITE, LANDSCAPE & ELEVATIONS PLANS7'-5" REVISION TABLE NUMBER DATE REVISED BY DESCRIPTION ASSOCIATES IN BUILDING & DESIGN C 2016 SPRINGER INVESTMENT GROUP SPRINGER PLAZA 4519 S. COLLEGE DR. FORT COLLINS, CO 80525 JOB # 2757 SHEET: Checked By: TER Drawings By: TER Issued For: CONCEPT DATE: 12/12/2016 PROPOSED WORK AREA (SHADED) B18R SB40 SB42 B18RB25R SB40 SB42 B25R RTC352496 W3436 W341815 W1236RDCW2436R W2436RW3136 2850FX 3068 80710MU80710MU3068 5068 3168 6080 3068 3168 2668 3068 3068 w/d R R R R R R R R R 350 SQ FT 124 SQ FT 15 SQ FT 138 SQ FT 59 SQ FT 414 SQ FT 81 SQ FT 34 SQ FT 35 SQ FT 10'-6" 28'-8" 11'-4" 10'-10" 3 1/2" 1'-10" 3 1/2" 2'-6" 3 1/2" 3'-9" 3 1/2" 2'-10" 5 1/2" 4'-3 3/4" 3'-2" 8'-1" 3'-2" 8'-1" 2'-2" 3'-2" 10" 1'-4" 6'-8" 5'-8"6'-2"5'-8"3'-2" 32'20' 28'-8" LIVING KITCHEN BATH B18R SB40 SB42 B18R B25R SB40 SB42 B25R RTC352496 W3436 W341815 W1236R DCW2436R W2436R W3136 2850FX 3068 80710MU 80710MU 3068 5068 3168 6080 3068 3168 2668 3068 3068 w/d R R R R R R R R R 350 SQ FT 124 SQ FT 15 SQ FT 138 SQ FT 59 SQ FT 414 SQ FT 81 SQ FT 34 SQ FT 35 SQ FT 28'-8" 11'-4" 10'-10" 3 1/2" 1'-10" 3 1/2" 2'-6" 3 1/2" 3'-9" 3 1/2" 2'-10" 5 1/2" 4'-3 3/4" 3'-2" 8'-1" 3'-2" 8'-1" 2'-2" 3'-2" 10" 1'-4" 6'-8" 5'-8" 6'-2" 5'-8" 3'-2" 32' 20' 28'-8" LIVING KITCHEN BATH HALL REVISION TABLE NUMBER DATE REVISED BY DESCRIPTION ASSOCIATES IN BUILDING & DESIGN C 2016 SPRINGER INVESTMENT GROUP SPRINGER PLAZA 4519 S. COLLEGE DR. FORT COLLINS, CO 80525 JOB # 2757 SHEET: Checked By: TER Drawings By: TER Issued For: CONCEPT DATE: 12/12/2016 PROPOSED WORK AREA PROPOSED WORK AREA PROPOSED WORK AREA Note 3: Garage door to be replaced with Commercial Double Door Note 2: Address and Wayfinding to be posted per code. BEDROOM DINING CLOSET HALL GARAGE 10080 10080 6068 6874FA 10080 10080 3068 28'-0" X 30'-9" 1'-4" 10' 2' 10' 5'-4" 1'-4" 10' 2' 10' 1'-4" 3'-2" 10" 28'-8" 32' 28'-8" LIVING AREA GARAGE REVISION TABLE NUMBER DATE REVISED BY DESCRIPTION ASSOCIATES IN BUILDING & DESIGN C 2016 SPRINGER INVESTMENT GROUP SPRINGER PLAZA 4519 S. COLLEGE DR. FORT COLLINS, CO 80525 JOB # 2757 SHEET: Checked By: TER Drawings By: TER Issued For: CONCEPT DATE: 12/12/2016 Proposed Concept Floor Plan Scale: 1/4"=1' Existing Floor Plan Scale: 1/4"=1' EXISTING 4" SEWER EXISTING 1" WATER HALL BEDROOM DINING CLOSET HALL GARAGE REVISION TABLE NUMBER DATE REVISED BY DESCRIPTION ASSOCIATES IN BUILDING & DESIGN C 2016 SPRINGER INVESTMENT GROUP SPRINGER PLAZA 4519 S. COLLEGE DR. FORT COLLINS, CO 80525 JOB # 2757 SHEET: Checked By: TER Drawings By: TER Issued For: CONCEPT DATE: 12/12/2016 UTILITY PLAN PROPOSED WORK AREA Note 1: Sprinkler system in new Retail Storage Area Note 2: Address Identification and Wayfinding for new residence per code. Note 3: Garage door to be replaced with Commercial Double Door per code. Note 4: New water and sewer service installed separate from existing utility services. (NEW WATER TAP SHALL BE 3/4" SADDLE TAP & CURB STOP TO BE LOCATED IN LANDSCAPING ) Note 5: Allocation and labeling for one parking space for residence. EXISTING MANHOLE Rim=5035.74 Inv.8"N=5030.2+- Inv.8"S=5030.2+- FIELD VERIFY EXISTING MANHOLE LOCATION EXISTING MANHOLE Sta.=0+00 Rim=5037.23 Inv. 8"N=5032.93+- Inv. 8"E=5032.93+- EXISTING 1 1/2"WATER METER VAULT FOR McDONALDS EXISTING 6" WATER EXISTING 8" SEWER EXISTING 4" SEWER EXISTING 1" WATER EXISTING LANDSCAPING OPTION TO BE RELOCATED EXISTING LANDSCAPING TO REMAIN 8"X6" Tapping Sleeve with t.B. with 6" Gate valve to East (EXISTING) 6" FL (EXISTING) EXISTING 8" STORM DRAIN EXISTING 8" STORM DRAIN 10' min. 6" D.I.P FIRE SERVICE (EXISTING) NEW 4" SEWER NEW 3/4" WATER