HomeMy WebLinkAboutBEEBE CHRISTIAN SCHOOL - PDP - PDP160022 - CORRESPONDENCE - (3)Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov.com/developmentreview November 28, 2016 Cathy Mathis TB GROUP 444 MOUNTAIN AVENUE Berthoud, CO 80513 RE: Beebe Christian School, PDP160022, Round Number 2 Comment Summary: Department: Engineering Development Review Contact: Katie Andrews, 970-221-6501, kandrews@fcgov.com Topic: General 11/22/2016: High volume driveways will be concrete to the property line per detail 707.1 – please show this on the plan. Please remove crosspan detail 710. Comment Number: 5 Comment Originated: 11/22/2016 11/22/2016: Please use LCUASS Table 8-2 to determine the appropriate curb return radii for the driveways and label these on the plan. Comment Number: 6 Comment Originated: 11/22/2016 11/22/2016: All concrete and pavement in the right-of-way will need to be designed to City standards and the design details are City (LCUASS) details. Please remove the hatching which links these public improvements to the detail/legend currently shown on the plan. Comment Number: 7 Comment Originated: 11/22/2016 11/22/2016: Please add cut note. "Limits of street cut are approximate. Final limits are to be determined in the field by the City Engineering Inspector. All repairs to be in accordance with City street repair standards." Comment Number: 8 Comment Originated: 11/22/2016 11/22/2016: Please show the other sides of Joseph Allen and Nancy Gray as they exist for context/driveway spacing. Comment Number: 9 Comment Originated: 11/22/2016 11/22/2016: The legend should say "std duty concrete (sidewalk)" not "std duty asphalt (sidewalk)" Comment Number: 10 Comment Originated: 11/22/2016 11/22/2016: Please add date (month, year) to the cover sheet above the vicinity map. Comment Number: 11 Comment Originated: 11/22/2016 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Ryan Mounce, at 970-224-6186 or rmounce@fcgov.com. Page 1 of 12 11/22/2016: Please update general note 19 with correct drainage study reference. Comment Number: 12 Comment Originated: 11/22/2016 Contact: Sheri Langenberger, 970-221-6573, slangenberger@fcgov.com Topic: General 07/28/2016: An additional $695 is due for the TDRF. There was not a plat included with the project, but according to the Larimer County website the parcel size is 6.11 acres, which differs from that included in the fee sheet and that is why the difference. Comment Number: 1 Comment Originated: 07/28/2016 Department: Forestry Contact: Molly Roche, , mroche@fcgov.com Topic: Landscape Plans 11/23/2016: The first tree east of Joseph Allen Drive on Nancy Gray Avenue appears to be too close to the stop sign and may not work in this area. Please provide at least 20' spacing between tree and sign or omit the tree. Comment Number: 7 Comment Originated: 11/23/2016 11/23/2016: English Oak suffered some freeze damage during the 2014 freeze. Forestry would prefer not to use them as street trees on this project. In their place, please use Kentucky Coffeetree. Comment Number: 8 Comment Originated: 11/23/2016 11/23/2016: At the corner of Nancy Gray Avenue and Timberline, please keep the 1st tree on Timberline well back from corner to provide for good line of sight. Comment Number: 9 Comment Originated: 11/23/2016 11/23/2016: Lindens typically do not survive or thrive well in parking lot islands and peninsulas. Please evaluate changing Lindens in these locations for better adapted shade trees. Comment Number: 10 Comment Originated: 11/23/2016 11/23/2016: Chokeberry (Prunus maackii) tends to decline at a fairly early age in Fort Collins. Consider using a better adapted ornamental tree in its place. Comment Number: 11 Comment Originated: 11/23/2016 Contact: Tim Buchanan, 970-221-6361, tbuchanan@fcgov.com Topic: Landscape Plans 11/23/2016: Continued 08/12/2016: Street trees appear to be spaced closer than 30 feet. The LUC standard is spacing at 30-40 feet. Adjust spacing of street trees. Comment Number: 4 Comment Originated: 08/12/2016 Department: Internal Services Contact: Russell Hovland, 970-416-2341, rhovland@fcgov.com Topic: Building Insp Plan Review Page 2 of 12 08/16/2016: Building Permit Pre-Submittal Meeting: Pre-Submittal meetings are required to assist the designer/builder by assuring, early on in the design, that the new commercial or multi-family projects are on track to complying with all of the adopted City codes and Standards listed below. The proposed project should be in the early to mid-design stage for this meeting to be effective and is typically scheduled after the Current Planning conceptual review meeting. Applicants of new commercial or multi-family projects are advised to call 416-2341 to schedule a pre-submittal meeting. Applicants should be prepared to present site plans, floor plans, and elevations and be able to discuss code issues of occupancy, square footage and type of construction being proposed. Construction shall comply with the following adopted codes as amended: 2012 International Building Code (IBC) 2012 International Residential Code (IRC) 2012 International Energy Conservation Code (IECC) 2012 International Mechanical Code (IMC) 2012 International Fuel Gas Code (IFGC) 2012 International Plumbing Code (IPC) as amended by the State of Colorado 2014 National Electrical Code (NEC) as amended by the State of Colorado Fort Collins has amendments to most of the codes listed above. See the fcgov.com web page to view them. Accessibility: State Law CRS 9-5 & ICC/ANSI A117.1-2009. Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF. Frost Depth: 30 inches. Wind Load: 100- MPH 3 Second Gust Exposure B. Seismic Design: Category B. Climate Zone: Zone 5 Energy Code Use 1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC. 2. Multi-family and Condominiums 3 stories max: 2012 IECC residential chapter. 3. Commercial and Multi-family 4 stories and taller: 2012 IECC commercial chapter. Beebe – project specific concerns: 1. Fire-sprinkler systems are required for buildings larger than 5k sq.ft. or fire containment walls required. 2. Upgraded insulation is required for buildings using electric heat or cooling. 3. Exterior walls and roof must meet a STC (sound resistance) rating of 40 min. if building located within 1000ft to train tracks. 4. Low-flow Watersense plumbing fixtures (toilet, faucets, shower heads) are required. 5. Low VOC interior finishes. City of Fort Collins Building Services Plan Review 416-2341 Comment Number: 1 Comment Originated: 08/16/2016 Department: Light And Power Page 3 of 12 Contact: Coy Althoff, , CAlthoff@fcgov.com Topic: General 08/09/2016: 3-Phase power is available to this area. Comment Number: 1 Comment Originated: 08/09/2016 08/09/2016: Development charges, electric Capacity Fee, Building Site charges and any system modification charges necessary will apply to this development. Comment Number: 2 Comment Originated: 08/09/2016 08/09/2016: Contact Light and Power Engineering to coordinate the transformer and electric meter locations, please show the locations on the utility plans. ***NOTE*** Transformer minimum clearances are 8' from the front and 3' around the back and sides and must be within 10' of a paved surface. Comment Number: 3 Comment Originated: 08/09/2016 08/09/2016: Please provide a one line diagram and a C-1 form to Light and Power Engineering. The C-1 form can be found at: http://zeus.fcgov.com/utils-procedures/files/EngWiki/WikiPdfs/C/C-1Form.pdf Comment Number: 4 Comment Originated: 08/09/2016 08/09/2016: You may contact FCU Light & Power, project engineering if you have questions. (970) 221-6700. You may reference Light & Power¿s Electric Service Standards at http://www.fcgov.com/utilities/img/site_specific/uploads/ElectricServiceStandards_F INAL_17June2016.pdf You may reference our policies, development charge processes, and use our fee estimator at http://www.fcgov.com/utilities/business/builders-and-developers. Comment Number: 5 Comment Originated: 08/09/2016 11/18/2016: No changes on behalf of Light & Power since the original comments were written on 8/9/16. Please contact us directly if you have questions. Comment Number: 6 Comment Originated: 11/18/2016 Department: Outside Agencies Contact: Ryan Mounce, 970-224-6186, rmounce@fcgov.com Topic: General 08/09/2016: Comment made by Don Kapperman, Comcast, 970-484-7166. Run 2'' conduit from IT Room out to Comcast Pedestal. Comment Number: 1 Comment Originated: 08/09/2016 Department: PFA Contact: Jim Lynxwiler, 970-416-2869, jlynxwiler@poudre-fire.org Topic: General Page 4 of 12 11/10/2016: FIRE ACCESS Fire access is required to within 150' of all exterior portions of any building, or facility as measured by an approved route around the building perimeter. The proposed site plan does not currently provide for sufficient fire access as defined by the International Fire Code. The following actions will be needed in order to satisfy this access requirement: > A fire lane will be required on the subject property. The drive aisles on the west and south sides of the building will need to be dedicated by separate document as an Emergency Access Easement. The limits of the EAE will need to be labeled on future plans and the fire lane will need to meet minimum specifications (provided below). > The road to the north of the property line may be used to calculate fire department access if documentation can be provided to show a permanent cross-property agreement can be maintained to an existing EAE. Otherwise, another means of providing fire access to the north side of the building will need to be explored. In either case, fire access must remain open and accessible at all times. (i.e. not blocked by non-gated fencing, potential road realignment, or building footprint). Comment Number: 1 Comment Originated: 07/28/2016 11/22/2016: FIRE LANE SPECIFICATIONS A fire lane plan shall be submitted for approval prior to installation. In addition to the design criteria already contained in relevant standards and policies, any new fire lane must meet the following general requirements: > Shall be designated on the plat as an Emergency Access Easement. > Maintain the required 20 foot minimum unobstructed width & 14 foot minimum overhead clearance. > Be designed as a flat, hard, all-weather driving surface capable of supporting 40 tons. > The required turning radii of a fire apparatus access road shall be a minimum of 25 feet inside and 50 feet outside. Turning radii shall be detailed on submitted plans. > Be visible by painting and/or signage, and maintained unobstructed at all times. Sign locations or red curbing should be labeled and detailed on final plans. > Additional access requirements exist for buildings greater than 30' in height. Refer to Appendix D of the 2012 IFC or contact PFA for details. International Fire Code 503.2.3, 503.2.4, 503.2.5, 503.3, 503.4 and Appendix D; FCLUC 3.6.2(B)2006 and Local Amendments. Comment Number: 2 Comment Originated: 11/10/2016 11/22/2016: FIRE LANE SIGNS The limits of the fire lane shall be fully defined. Fire lane sign locations should be indicated on future plan sets. Code language provided below. > IFC D103.6: Where required by the fire code official, fire apparatus access roads shall be marked with permanent NO PARKING - FIRE LANE signs complying with Figure D103.6. Signs shall have a minimum dimension of 12 inches wide by 18 inches high and have red letters on a white reflective background. Signs shall be posted on one or both sides of the fire apparatus road as required by Section D103.6.1 or D103.6.2. Comment Number: 3 Comment Originated: 11/22/2016 11/22/2016: FDC > IFC 912.2: Fire Department Connections shall be installed in accordance with NFPA standards. Fire department connections shall be located on the street side of buildings, fully visible and recognizable from the street or nearest point of fire department vehicle access. The location of the FDC shall be approved by the fire department. Comment Number: 4 Comment Originated: 11/22/2016 Page 5 of 12 11/22/2016: KEY BOXES REQUIRED > IFC 506.1 and Poudre Fire Authority Bureau Policy 88-20: Poudre Fire Authority requires at least one key box ("Knox Box") to be mounted in an approved, exterior location (or locations) on every new or existing building equipped with a required fire sprinkler or fire alarm system. The box shall be positioned 3 to 7 feet above finished floor and within 10 feet of the front door, or closest door to the fire alarm panel. Exception can be made by the PFA if it is more logical to have the box located somewhere else on the structure. Knox Box size and location(s) to be determined by time of final CO. Comment Number: 5 Comment Originated: 11/22/2016 11/22/2016: EXITING REQUIREMENTS A full plan review will be provided at time of building permit; however a peripheral examination of the proposed floor plan indicates some potential problems related to egress requirements. There appears to be numerous rooms for assembly or education having a potential occupant load greater than 49 persons. Any room with a calculated occupant load greater than 49 persons will required a minimum of two exits. All doors leading out of such require the doors to swing in the direction of egress travel. At this time, several rooms appear to provide one exit when two will be required. Numerous doors swing opposite to the direction of egress travel. Refer to IFC or IBC Chapter 10 for further information. Comment Number: 6 Comment Originated: 11/22/2016 Department: Planning Services Contact: Ryan Mounce, 970-224-6186, rmounce@fcgov.com Topic: General 11/21/2016: The new building location is an improvement on meeting the build-to lines given existing easements and drainage channels. However, a modification of standard is still required given the vehicle use area located between the building entrance and the street. In submitting a modification request for analysis, please focus on how the project can enhance this realm through landscaping and user needs, such as convenience and safety for pedestrian and handicap users, as well as discussion of existing constraints of the drainage channel along Timberline Road. Comment Number: 1 Comment Originated: 08/02/2016 11/21/2016: If a new plat is being developed for the site, a preliminary version will need to be reviewed prior to a public hearing. Comment Number: 3 Comment Originated: 08/02/2016 11/21/2016: The new landscaping plan and added trees are a great addition to project plans. Staff is especially appreciative of the continuation of the tree palette and design in the drainage channel fronting Timberline Rd. Comment Number: 5 Comment Originated: 08/02/2016 11/21/2016: A direct connection to the school entrance is still needed from Nancy Gray Avenue; the current route is very circuitous, especially if coming from the west. Where this connection crosses the one-way drive aisle, special paving or crossing elements should be used to emphasize the pedestrian. Comment Number: 7 Comment Originated: 08/02/2016 Page 6 of 12 11/21/2016: On the northwestern portion of the site plan a walkway is shown – the neighboring climbing gym wrapping up construction also has a walkway approximately 5-10 feet to the north within an access easement. You could consider linking to this walkway. Comment Number: 8 Comment Originated: 08/02/2016 08/02/2016: It appears the east church façade facing Timberline Road still features a couple blank walls exceeding 30-feet without additional articulation or interest. I'd like to explore what options are available to improve these walls, whether any windows, materials changes, or trellises are potential solutions to add visual interest. Comment Number: 9 Comment Originated: 08/02/2016 11/21/2016: On the elevation drawings, please include photos/examples of the color or finishes of the proposed building materials (stucco, CMU, metal building roof). Please also specify the color for the vinyl wrapping on the chain-link fence. Comment Number: 10 Comment Originated: 08/02/2016 11/28/2016: As the project has evolved to include more of a focus on the church in relationship to the school, a modification of standard should be submitted for the mix of primary and secondary uses in the employment zone district. While schools are considered a primary use, places of worship are considered secondary uses, and the allotment of secondary uses for this site was already reserved for the single-family homes west of Joseph Allen Drive. Comment Number: 14 Comment Originated: 11/28/2016 11/28/2016: With the inclusion of a subdivision plat, additional review fees for planning and engineering (transportation development review) are required. The base Project Development Plan review fee submitted was $3,887; however with a plat, the fee is $5,879. The difference ($1,992) will need to be collected when the subdivision plat is submitted. When the subdivision plat is completed, please send me information on the size of the parcel in acres, which will be required to determine the updated transportation development review fees. Comment Number: 15 Comment Originated: 11/28/2016 Department: Stormwater Engineering Contact: Heather McDowell, 970-224-6065, hmcdowell@fcgov.com Topic: Drainage Report 11/22/2016: Drainage Report – In addition to the Timberline Road Widening project and the Police Services Building project drainage reports, the Spring Creek Farms North drainage report and also the Sidehill Filing 2 Stormwater pipe reduction drainage report will need to be referenced for this site. The maximum release rate from the pond will need to be capped at 1.1 cfs. Please re-run the detention pond volume analysis with this runoff. All of the above mentioned drainage reports can be found on Citydocs on our website. Please contact me if you need help finding these. (Prelim) Comment Number: 18 Comment Originated: 11/22/2016 11/22/2016: Drainage Report – it looks like you re-analyzed the offsite basins (OS-7 which is Nancy Gray Ave, and PS-1 which is the Police Services Bldg site) for inclusion into your pond calculations. You don’t need to re-analyze these basins, simply utilize the information already provided in the other drainage reports for these areas. (Prelim) Comment Number: 19 Comment Originated: 11/22/2016 Page 7 of 12 11/22/2016: Drainage Report – Per the Spring Creek Farms North drainage report, the bottom portion (~1.3 feet or up to the top of the WQ orifice plate) of the existing detention pond is for the WQCV. Please ensure that you’re calculating the required volume for the quantity detention above the WQCV elevation. (Prelim) Comment Number: 20 Comment Originated: 11/22/2016 11/22/2016: Drainage Report – 100-yr orifice on the existing outlet structure will need to be checked to verify that the maximum flow through the orifice is no more than the 1.1 cfs allowed. (Final) Comment Number: 21 Comment Originated: 11/22/2016 11/22/2016: Drainage Report – see the redlined report for other minor comments. Comment Number: 22 Comment Originated: 11/22/2016 Topic: General 11/22/2016: Grading Plan - Please include additional slope labels on the grading plan. (Final) 08/08/2016: Grading Plan ¿ Please include slope labels on the grading plan. Comment Number: 1 Comment Originated: 08/08/2016 11/22/2016: Grading Plan – The east parking lot entry off of Nancy Gray Avenue indicates a “ridge line” across the access, presumably to capture onsite runoff and route it to the curb chase and rain garden. However, a 0.04’ elevation difference is not sufficient enough to capture the onsite flows. Please modify the grading in this area. (Preliminary) Comment Number: 13 Comment Originated: 11/22/2016 11/22/2016: Grading Plan – Please also include the storm pipes exiting from the rain gardens and the roof drains on the overall utility plan. (Final) Comment Number: 14 Comment Originated: 11/22/2016 11/22/2016: Grading Plan – per our design standards, please provide some slope variation and undulation with the portion of the detention pond that you’re proposing to regrade. (Preliminary) Comment Number: 15 Comment Originated: 11/22/2016 11/22/2016: Grading Plan – per our criteria manual, Chapter 7, Section 4.3.3.3, we discourage the use of riprap and encourage the use of other types of permanent erosion control materials, such as Scour Stop or equivalent. (Final) Comment Number: 16 Comment Originated: 11/22/2016 11/22/2016: Grading Plan – it doesn’t look like you’ve provided any vertical separation between the FF of the building and the finished grade along it on the east side. Please revise. (Final) Comment Number: 17 Comment Originated: 11/22/2016 Contact: Jesse Schlam, 970-218-2932, jschlam@fcgov.com Topic: Erosion Control Page 8 of 12 11/23/2016: Current Erosion Control Materials Submitted do not meet requirements. Please submit; Erosion Control Plan (based on redlined comments), Erosion Control Report (based on redline comments), and an Escrow / Security Calculation (based upon any changes to the erosion control plan) . If you need clarification concerning the erosion control section, or if there are any questions please contact Jesse Schlam 970-218-2932 or email @ jschlam@fcgov.com 08/09/2016: Current Erosion Control Materials Submitted do not meet requirements. Please submit; Erosion Control Plan (based on redlined comments), Erosion Control Report (based on redline comments), and an Escrow / Security Calculation (based upon any changes to the erosion control plan) . If you need clarification concerning the erosion control section, or if there are any questions please contact Jesse Schlam 970-218-2932 or email @ jschlam@fcgov.com Comment Number: 12 Comment Originated: 08/09/2016 Department: Technical Services Contact: Jeff County, 970-221-6588, jcounty@fcgov.com Topic: Building Elevations 11/22/2016: There are line over text issues. See redlines. 08/08/2016: There are line over text issues. See redlines. Comment Number: 6 Comment Originated: 08/08/2016 Topic: Construction Drawings 11/22/2016: Please change the name in the title block to match the main title on all sheets. See redlines. 08/09/2016: Please change the name to "Beebe Christian School". Comment Number: 8 Comment Originated: 08/09/2016 11/22/2016: We acknowledge your response. A benchmark statement must be added based on NAVD88 in the EXACT format shown below. PROJECT DATUM: NAVD88 BENCHMARK # w/ DESCRIPTION ELEVATION: BENCHMARK # w/ DESCRIPTION ELEVATION: PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - X.XX’. 08/09/2016: We did not see any benchmarks or benchmark statement shown on the plans. Comment Number: 9 Comment Originated: 08/09/2016 11/22/2016: Some of the sheet titles & sheet numbers in the index do not match the sheet titles on the noted sheets. 08/09/2016: Some of the sheet titles in the sheet index do not match the sheet titles on the noted sheets. Comment Number: 10 Comment Originated: 08/09/2016 Page 9 of 12 11/23/2016: There are line over text issues. See redlines. 08/09/2016: There are line over text issues. See redlines. Comment Number: 11 Comment Originated: 08/09/2016 11/23/2016: There is text that needs to be masked. Mask all text in hatched areas. See redlines. 08/09/2016: There is text that needs to be masked. Mask all text in hatched areas. See redlines. Comment Number: 12 Comment Originated: 08/09/2016 11/23/2016: This has been addressed. 08/09/2016: There is text that needs to be rotated 180 degrees. See redlines. Comment Number: 13 Comment Originated: 08/09/2016 11/23/2016: Please clean up the fuzzy text in the Outlet Structure detail on sheet 7. See redlines. Comment Number: 17 Comment Originated: 11/23/2016 Topic: Lighting Plan 11/22/2016: This has not been corrected. 08/08/2016: Please change the name to "Beebe Christian School". Comment Number: 7 Comment Originated: 08/08/2016 11/22/2016: Please change the title in the title block as marked. See redlines. Comment Number: 16 Comment Originated: 11/22/2016 Topic: Site Plan 11/22/2016: Please add a metes & bounds description of the portion of Tract A that this project is located. We suggest consulting with a Land Surveyor for this. 08/08/2016: Please include in the legal description the Metes & Bounds description of the "portion" of Outlot A. Comment Number: 1 Comment Originated: 08/08/2016 11/22/2016: Some of the sheet titles in the sheet index do not match the sheet titles on the noted sheets. See redlines. Comment Number: 14 Comment Originated: 11/22/2016 11/22/2016: There are some sheets missing from the sheet index. Comment Number: 15 Comment Originated: 11/22/2016 Department: Traffic Operation Contact: Nicole Hahn, 970-221-6820, nhahn@fcgov.com Topic: Traffic Impact Study 08/09/2016: Operational analysis for school drop off and pick up will need to be provided with next submittal. 11/22/2016: Analysis has been provided and the conclusions accepted. Comment Number: 1 Comment Originated: 08/09/2016 Department: Water Conservation Contact: Eric Olson, 970-221-6704, eolson@fcgov.com Topic: General Page 10 of 12 08/08/2016: Irrigation plans are required no later than at the time of building permit. The irrigation plans must comply with the provisions outlined in Section 3.2.1(J) of the Land Use Code. Direct questions concerning irrigation requirements to Eric Olson, at 221-6704 or eolson@fcgov.com Comment Number: 1 Comment Originated: 08/08/2016 Department: Water-Wastewater Engineering Contact: Heather McDowell, 970-224-6065, hmcdowell@fcgov.com Topic: General 11/22/2016: Utility Plan – For the proposed water service, please show the meter vault to scale. (Final) 08/08/2016: Utility Plan ¿ For the proposed water service, please show the proposed curb stop and water meter to scale and place them according to our standard details. Comment Number: 2 Comment Originated: 08/08/2016 11/22/2016: Utility Plan – please include the roof drains and storm pipes on this utility plan. (Final) Comment Number: 8 Comment Originated: 11/22/2016 11/22/2016: Utility Plan – it looks as though there are several notes on this page that are from another jurisdiction. Please remove all notes that do not specifically pertain to the City of Fort Collins. See redlined comments. (Final) Comment Number: 9 Comment Originated: 11/22/2016 11/22/2016: Utility Plan – Add a note regarding the abandonment of existing water or sewer services at the main. Contractor to coordinate with City of Fort Collins Field Operations for water or sewer line abandonment procedures during construction at (970) 221-6700. Also please add a note that reuse of the hydrant will be verified at the time of construction with CoFC Field Operations. (Final) Comment Number: 10 Comment Originated: 11/22/2016 Topic: Landscape Plans 11/22/2016: Landscape Plan – Please show the relocated hydrant on Joseph Allen Drive. You may need to shift a tree to provide 10-feet of separation from the hydrant. Please also check the separation between the relocated hydrant on Nancy Gray and the closest tree. (Prelim) Comment Number: 11 Comment Originated: 11/22/2016 11/22/2016: Landscape Plan – please ensure 6’ of separation between the water and sewer services and the proposed trees along Joseph Allen Drive parking lot frontage. (Prelim) Comment Number: 12 Comment Originated: 11/22/2016 11/22/2016: Landscape Plan – please relabel the water quality ponds as rain gardens. (Prelim) Comment Number: 13 Comment Originated: 11/22/2016 11/22/2016: Landscape Plan - a portion of the existing detention pond is going to have to be regraded, please remove the label on the detention pond that says “to be left undisturbed”. (Prelim) Comment Number: 14 Comment Originated: 11/22/2016 11/22/2016: Landscape Plan – I think the scale label is incorrect. (Prelim) Comment Number: 15 Comment Originated: 11/22/2016 Department: Zoning Page 11 of 12 Contact: Noah Beals, 970-416-2313, nbeals@fcgov.com Topic: General 11/21/2016: The sidewalk connection to the main door needs to enhanced and moved closer to the door. Comment Number: 12 Comment Originated: 11/21/2016 11/21/2016: The sidewalk along the north maybe redundant. Possibly consider a connection to the sidewalk on the property to the north. Comment Number: 13 Comment Originated: 11/21/2016 11/21/2016: The handicap parking spaces do not have to be bunched together. Comment Number: 14 Comment Originated: 11/21/2016 11/21/2016: The ramp for the handicap spaces do not have a landing. Comment Number: 15 Comment Originated: 11/21/2016 11/21/2016: The lighting levels are low in the drive aisle on the south side of the building. Comment Number: 16 Comment Originated: 11/21/2016 11/21/2016: The trash enclosure's walk-in access is not clear on the plans. Comment Number: 17 Comment Originated: 11/21/2016 Contact: Ryan Boehle, 970-416-2401, rboehle@fcgov.com Topic: General To establish "build-to" lines, buildings shall be located and designed to align or approximately align with any previously established building/sidewalk relationships that are consistent with this standard. Buildings shall be located no more than fifteen (15) feet from the right-of-way of an adjoining street if the street is smaller than a full arterial or has on-street parking. Comment Number: 2 Comment Originated: 08/09/2016 Site lighting needs to be provided as per 3.2.4 (C), a lighting plan, including photometrics and fixture cut sheets. Comment Number: 7 Comment Originated: 08/10/2016 3.5.1(I)(6) All mechanical equipment, meters, conduit, vents and RTU’s shall be screened from public view both from above and below by integrating it into the building and roof design. Comment Number: 9 Comment Originated: 08/10/2016 Page 12 of 12