November 28, 2016
Cathy Mathis
TB GROUP
444 MOUNTAIN AVENUE
Berthoud, CO 80513
RE: Beebe Christian School, PDP160022, Round Number 2
Comment Summary:
Department: Engineering Development Review
Contact: Katie Andrews, 970-221-6501, kandrews@fcgov.com
Topic: General
11/22/2016: High volume driveways will be concrete to the property line per detail
707.1 – please show this on the plan. Please remove crosspan detail 710.
Comment Number: 5 Comment Originated: 11/22/2016
11/22/2016: Please use LCUASS Table 8-2 to determine the appropriate curb
return radii for the driveways and label these on the plan.
Comment Number: 6 Comment Originated: 11/22/2016
11/22/2016: All concrete and pavement in the right-of-way will need to be designed
to City standards and the design details are City (LCUASS) details. Please remove
the hatching which links these public improvements to the detail/legend currently
shown on the plan.
Comment Number: 7 Comment Originated: 11/22/2016
11/22/2016: Please add cut note. "Limits of street cut are approximate. Final limits
are to be determined in the field by the City Engineering Inspector. All repairs to be in
accordance with City street repair standards."
Comment Number: 8 Comment Originated: 11/22/2016
11/22/2016: Please show the other sides of Joseph Allen and Nancy Gray as they
exist for context/driveway spacing.
Comment Number: 9 Comment Originated: 11/22/2016
11/22/2016: The legend should say "std duty concrete (sidewalk)" not "std duty
asphalt (sidewalk)"
Comment Number: 10 Comment Originated: 11/22/2016
11/22/2016: Please add date (month, year) to the cover sheet above the vicinity
map.
Comment Number: 11 Comment Originated: 11/22/2016
Please see the following summary of comments from City staff and outside reviewing agencies for
your submittal of the above referenced project. If you have questions about any comments, you may
contact the individual commenter or direct your questions through the Project Planner, Ryan Mounce, at
970-224-6186 or rmounce@fcgov.com.
Page 1 of 12
11/22/2016: Please update general note 19 with correct drainage study reference.
Comment Number: 12 Comment Originated: 11/22/2016
Contact: Sheri Langenberger, 970-221-6573, slangenberger@fcgov.com
Topic: General
07/28/2016: An additional $695 is due for the TDRF. There was not a plat included
with the project, but according to the Larimer County website the parcel size is 6.11
acres, which differs from that included in the fee sheet and that is why the
difference.
Comment Number: 1 Comment Originated: 07/28/2016
Department: Forestry
Contact: Molly Roche, , mroche@fcgov.com
Topic: Landscape Plans
11/23/2016:
The first tree east of Joseph Allen Drive on Nancy Gray Avenue appears to be too
close to the stop sign and may not work in this area. Please provide at least 20'
spacing between tree and sign or omit the tree.
Comment Number: 7 Comment Originated: 11/23/2016
11/23/2016:
English Oak suffered some freeze damage during the 2014 freeze. Forestry would
prefer not to use them as street trees on this project. In their place, please use
Kentucky Coffeetree.
Comment Number: 8 Comment Originated: 11/23/2016
11/23/2016:
At the corner of Nancy Gray Avenue and Timberline, please keep the 1st tree on
Timberline well back from corner to provide for good line of sight.
Comment Number: 9 Comment Originated: 11/23/2016
11/23/2016:
Lindens typically do not survive or thrive well in parking lot islands and peninsulas.
Please evaluate changing Lindens in these locations for better adapted shade trees.
Comment Number: 10 Comment Originated: 11/23/2016
11/23/2016:
Chokeberry (Prunus maackii) tends to decline at a fairly early age in Fort Collins.
Consider using a better adapted ornamental tree in its place.
Comment Number: 11 Comment Originated: 11/23/2016
Contact: Tim Buchanan, 970-221-6361, tbuchanan@fcgov.com
Topic: Landscape Plans
11/23/2016: Continued
08/12/2016:
Street trees appear to be spaced closer than 30 feet. The LUC standard is spacing
at 30-40 feet. Adjust spacing of street trees.
Comment Number: 4 Comment Originated: 08/12/2016
Department: Internal Services
Contact: Russell Hovland, 970-416-2341, rhovland@fcgov.com
Topic: Building Insp Plan Review
Page 2 of 12
08/16/2016:
Building Permit Pre-Submittal Meeting:
Pre-Submittal meetings are required to assist the designer/builder by assuring, early
on in the design,
that the new commercial or multi-family projects are on track to complying with all of
the adopted City
codes and Standards listed below. The proposed project should be in the early to
mid-design stage for
this meeting to be effective and is typically scheduled after the Current Planning
conceptual review
meeting. Applicants of new commercial or multi-family projects are advised to call
416-2341 to schedule
a pre-submittal meeting. Applicants should be prepared to present site plans, floor
plans, and elevations
and be able to discuss code issues of occupancy, square footage and type of
construction being proposed.
Construction shall comply with the following adopted codes as amended:
2012 International Building Code (IBC)
2012 International Residential Code (IRC)
2012 International Energy Conservation Code (IECC)
2012 International Mechanical Code (IMC)
2012 International Fuel Gas Code (IFGC)
2012 International Plumbing Code (IPC) as amended by the State of Colorado
2014 National Electrical Code (NEC) as amended by the State of Colorado
Fort Collins has amendments to most of the codes listed above. See the fcgov.com
web page to view them.
Accessibility: State Law CRS 9-5 & ICC/ANSI A117.1-2009.
Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF.
Frost Depth: 30 inches.
Wind Load: 100- MPH 3 Second Gust Exposure B.
Seismic Design: Category B.
Climate Zone: Zone 5
Energy Code Use
1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC.
2. Multi-family and Condominiums 3 stories max: 2012 IECC residential chapter.
3. Commercial and Multi-family 4 stories and taller: 2012 IECC commercial chapter.
Beebe – project specific concerns:
1. Fire-sprinkler systems are required for buildings larger than 5k sq.ft. or fire
containment walls required.
2. Upgraded insulation is required for buildings using electric heat or cooling.
3. Exterior walls and roof must meet a STC (sound resistance) rating of 40 min. if
building located within 1000ft to train tracks.
4. Low-flow Watersense plumbing fixtures (toilet, faucets, shower heads) are
required.
5. Low VOC interior finishes.
City of Fort Collins
Building Services
Plan Review
416-2341
Comment Number: 1 Comment Originated: 08/16/2016
Department: Light And Power
Page 3 of 12
Contact: Coy Althoff, , CAlthoff@fcgov.com
Topic: General
08/09/2016: 3-Phase power is available to this area.
Comment Number: 1 Comment Originated: 08/09/2016
08/09/2016: Development charges, electric Capacity Fee, Building Site charges
and any system modification charges necessary will apply to this development.
Comment Number: 2 Comment Originated: 08/09/2016
08/09/2016: Contact Light and Power Engineering to coordinate the transformer
and electric meter locations, please show the locations on the utility plans.
***NOTE*** Transformer minimum clearances are 8' from the front and 3' around
the back and sides and must be within 10' of a paved surface.
Comment Number: 3 Comment Originated: 08/09/2016
08/09/2016: Please provide a one line diagram and a C-1 form to Light and Power
Engineering. The C-1 form can be found at:
http://zeus.fcgov.com/utils-procedures/files/EngWiki/WikiPdfs/C/C-1Form.pdf
Comment Number: 4 Comment Originated: 08/09/2016
08/09/2016: You may contact FCU Light & Power, project engineering if you have
questions. (970) 221-6700. You may reference Light & Power¿s Electric Service
Standards at
http://www.fcgov.com/utilities/img/site_specific/uploads/ElectricServiceStandards_F
INAL_17June2016.pdf
You may reference our policies, development charge processes, and use our fee
estimator at http://www.fcgov.com/utilities/business/builders-and-developers.
Comment Number: 5 Comment Originated: 08/09/2016
11/18/2016: No changes on behalf of Light & Power since the original comments
were written on 8/9/16. Please contact us directly if you have questions.
Comment Number: 6 Comment Originated: 11/18/2016
Department: Outside Agencies
Contact: Ryan Mounce, 970-224-6186, rmounce@fcgov.com
Topic: General
08/09/2016: Comment made by Don Kapperman, Comcast, 970-484-7166.
Run 2'' conduit from IT Room out to Comcast Pedestal.
Comment Number: 1 Comment Originated: 08/09/2016
Department: PFA
Contact: Jim Lynxwiler, 970-416-2869, jlynxwiler@poudre-fire.org
Topic: General
Page 4 of 12
11/10/2016: FIRE ACCESS
Fire access is required to within 150' of all exterior portions of any building, or facility
as measured by an approved route around the building perimeter. The proposed site
plan does not currently provide for sufficient fire access as defined by the
International Fire Code. The following actions will be needed in order to satisfy this
access requirement:
> A fire lane will be required on the subject property. The drive aisles on the west
and south sides of the building will need to be dedicated by separate document as
an Emergency Access Easement. The limits of the EAE will need to be labeled on
future plans and the fire lane will need to meet minimum specifications (provided
below).
> The road to the north of the property line may be used to calculate fire department
access if documentation can be provided to show a permanent cross-property
agreement can be maintained to an existing EAE. Otherwise, another means of
providing fire access to the north side of the building will need to be explored. In
either case, fire access must remain open and accessible at all times. (i.e. not
blocked by non-gated fencing, potential road realignment, or building footprint).
Comment Number: 1 Comment Originated: 07/28/2016
11/22/2016: FIRE LANE SPECIFICATIONS
A fire lane plan shall be submitted for approval prior to installation. In addition to the
design criteria already contained in relevant standards and policies, any new fire
lane must meet the following general requirements:
> Shall be designated on the plat as an Emergency Access Easement.
> Maintain the required 20 foot minimum unobstructed width & 14 foot minimum
overhead clearance.
> Be designed as a flat, hard, all-weather driving surface capable of supporting 40
tons.
> The required turning radii of a fire apparatus access road shall be a minimum of
25 feet inside and 50 feet outside. Turning radii shall be detailed on submitted plans.
> Be visible by painting and/or signage, and maintained unobstructed at all times.
Sign locations or red curbing should be labeled and detailed on final plans.
> Additional access requirements exist for buildings greater than 30' in height. Refer
to Appendix D of the 2012 IFC or contact PFA for details.
International Fire Code 503.2.3, 503.2.4, 503.2.5, 503.3, 503.4 and Appendix D;
FCLUC 3.6.2(B)2006 and Local Amendments.
Comment Number: 2 Comment Originated: 11/10/2016
11/22/2016: FIRE LANE SIGNS
The limits of the fire lane shall be fully defined. Fire lane sign locations should be
indicated on future plan sets. Code language provided below.
> IFC D103.6: Where required by the fire code official, fire apparatus access roads
shall be marked with permanent NO PARKING - FIRE LANE signs complying with
Figure D103.6. Signs shall have a minimum dimension of 12 inches wide by 18
inches high and have red letters on a white reflective background. Signs shall be
posted on one or both sides of the fire apparatus road as required by Section
D103.6.1 or D103.6.2.
Comment Number: 3 Comment Originated: 11/22/2016
11/22/2016: FDC
> IFC 912.2: Fire Department Connections shall be installed in accordance with
NFPA standards. Fire department connections shall be located on the street side of
buildings, fully visible and recognizable from the street or nearest point of fire
department vehicle access. The location of the FDC shall be approved by the fire
department.
Comment Number: 4 Comment Originated: 11/22/2016
Page 5 of 12
11/22/2016: KEY BOXES REQUIRED
> IFC 506.1 and Poudre Fire Authority Bureau Policy 88-20: Poudre Fire Authority
requires at least one key box ("Knox Box") to be mounted in an approved, exterior
location (or locations) on every new or existing building equipped with a required fire
sprinkler or fire alarm system. The box shall be positioned 3 to 7 feet above finished
floor and within 10 feet of the front door, or closest door to the fire alarm panel.
Exception can be made by the PFA if it is more logical to have the box located
somewhere else on the structure. Knox Box size and location(s) to be determined
by time of final CO.
Comment Number: 5 Comment Originated: 11/22/2016
11/22/2016: EXITING REQUIREMENTS
A full plan review will be provided at time of building permit; however a peripheral
examination of the proposed floor plan indicates some potential problems related to
egress requirements. There appears to be numerous rooms for assembly or
education having a potential occupant load greater than 49 persons.
Any room with a calculated occupant load greater than 49 persons will required a
minimum of two exits. All doors leading out of such require the doors to swing in the
direction of egress travel. At this time, several rooms appear to provide one exit
when two will be required. Numerous doors swing opposite to the direction of
egress travel. Refer to IFC or IBC Chapter 10 for further information.
Comment Number: 6 Comment Originated: 11/22/2016
Department: Planning Services
Contact: Ryan Mounce, 970-224-6186, rmounce@fcgov.com
Topic: General
11/21/2016: The new building location is an improvement on meeting the build-to
lines given existing easements and drainage channels. However, a modification of
standard is still required given the vehicle use area located between the building
entrance and the street.
In submitting a modification request for analysis, please focus on how the project
can enhance this realm through landscaping and user needs, such as convenience
and safety for pedestrian and handicap users, as well as discussion of existing
constraints of the drainage channel along Timberline Road.
Comment Number: 1 Comment Originated: 08/02/2016
11/21/2016: If a new plat is being developed for the site, a preliminary version will
need to be reviewed prior to a public hearing.
Comment Number: 3 Comment Originated: 08/02/2016
11/21/2016: The new landscaping plan and added trees are a great addition to
project plans. Staff is especially appreciative of the continuation of the tree palette
and design in the drainage channel fronting Timberline Rd.
Comment Number: 5 Comment Originated: 08/02/2016
11/21/2016: A direct connection to the school entrance is still needed from Nancy
Gray Avenue; the current route is very circuitous, especially if coming from the west.
Where this connection crosses the one-way drive aisle, special paving or crossing
elements should be used to emphasize the pedestrian.
Comment Number: 7 Comment Originated: 08/02/2016
Page 6 of 12
11/21/2016: On the northwestern portion of the site plan a walkway is shown – the
neighboring climbing gym wrapping up construction also has a walkway
approximately 5-10 feet to the north within an access easement. You could consider
linking to this walkway.
Comment Number: 8 Comment Originated: 08/02/2016
08/02/2016: It appears the east church façade facing Timberline Road still features
a couple blank walls exceeding 30-feet without additional articulation or interest. I'd
like to explore what options are available to improve these walls, whether any
windows, materials changes, or trellises are potential solutions to add visual
interest.
Comment Number: 9 Comment Originated: 08/02/2016
11/21/2016: On the elevation drawings, please include photos/examples of the color
or finishes of the proposed building materials (stucco, CMU, metal building roof).
Please also specify the color for the vinyl wrapping on the chain-link fence.
Comment Number: 10 Comment Originated: 08/02/2016
11/28/2016: As the project has evolved to include more of a focus on the church in
relationship to the school, a modification of standard should be submitted for the mix
of primary and secondary uses in the employment zone district. While schools are
considered a primary use, places of worship are considered secondary uses, and
the allotment of secondary uses for this site was already reserved for the
single-family homes west of Joseph Allen Drive.
Comment Number: 14 Comment Originated: 11/28/2016
11/28/2016: With the inclusion of a subdivision plat, additional review fees for
planning and engineering (transportation development review) are required.
The base Project Development Plan review fee submitted was $3,887; however with
a plat, the fee is $5,879. The difference ($1,992) will need to be collected when the
subdivision plat is submitted.
When the subdivision plat is completed, please send me information on the size of
the parcel in acres, which will be required to determine the updated transportation
development review fees.
Comment Number: 15 Comment Originated: 11/28/2016
Department: Stormwater Engineering
Contact: Heather McDowell, 970-224-6065, hmcdowell@fcgov.com
Topic: Drainage Report
11/22/2016: Drainage Report – In addition to the Timberline Road Widening project
and the Police Services Building project drainage reports, the Spring Creek Farms
North drainage report and also the Sidehill Filing 2 Stormwater pipe reduction
drainage report will need to be referenced for this site. The maximum release rate
from the pond will need to be capped at 1.1 cfs. Please re-run the detention pond
volume analysis with this runoff. All of the above mentioned drainage reports can be
found on Citydocs on our website. Please contact me if you need help finding these.
(Prelim)
Comment Number: 18 Comment Originated: 11/22/2016
11/22/2016: Drainage Report – it looks like you re-analyzed the offsite basins (OS-7
which is Nancy Gray Ave, and PS-1 which is the Police Services Bldg site) for
inclusion into your pond calculations. You don’t need to re-analyze these basins,
simply utilize the information already provided in the other drainage reports for these
areas. (Prelim)
Comment Number: 19 Comment Originated: 11/22/2016
Page 7 of 12
11/22/2016: Drainage Report – Per the Spring Creek Farms North drainage report,
the bottom portion (~1.3 feet or up to the top of the WQ orifice plate) of the existing
detention pond is for the WQCV. Please ensure that you’re calculating the required
volume for the quantity detention above the WQCV elevation. (Prelim)
Comment Number: 20 Comment Originated: 11/22/2016
11/22/2016: Drainage Report – 100-yr orifice on the existing outlet structure will
need to be checked to verify that the maximum flow through the orifice is no more
than the 1.1 cfs allowed. (Final)
Comment Number: 21 Comment Originated: 11/22/2016
11/22/2016: Drainage Report – see the redlined report for other minor comments.
Comment Number: 22 Comment Originated: 11/22/2016
Topic: General
11/22/2016: Grading Plan - Please include additional slope labels on the grading
plan. (Final)
08/08/2016: Grading Plan ¿ Please include slope labels on the grading plan.
Comment Number: 1 Comment Originated: 08/08/2016
11/22/2016: Grading Plan – The east parking lot entry off of Nancy Gray Avenue
indicates a “ridge line” across the access, presumably to capture onsite runoff and
route it to the curb chase and rain garden. However, a 0.04’ elevation difference is
not sufficient enough to capture the onsite flows. Please modify the grading in this
area. (Preliminary)
Comment Number: 13 Comment Originated: 11/22/2016
11/22/2016: Grading Plan – Please also include the storm pipes exiting from the rain
gardens and the roof drains on the overall utility plan. (Final)
Comment Number: 14 Comment Originated: 11/22/2016
11/22/2016: Grading Plan – per our design standards, please provide some slope
variation and undulation with the portion of the detention pond that you’re proposing
to regrade. (Preliminary)
Comment Number: 15 Comment Originated: 11/22/2016
11/22/2016: Grading Plan – per our criteria manual, Chapter 7, Section 4.3.3.3, we
discourage the use of riprap and encourage the use of other types of permanent
erosion control materials, such as Scour Stop or equivalent. (Final)
Comment Number: 16 Comment Originated: 11/22/2016
11/22/2016: Grading Plan – it doesn’t look like you’ve provided any vertical
separation between the FF of the building and the finished grade along it on the east
side. Please revise. (Final)
Comment Number: 17 Comment Originated: 11/22/2016
Contact: Jesse Schlam, 970-218-2932, jschlam@fcgov.com
Topic: Erosion Control
Page 8 of 12
11/23/2016: Current Erosion Control Materials Submitted do not meet
requirements. Please submit; Erosion Control Plan (based on redlined comments),
Erosion Control Report (based on redline comments), and an Escrow / Security
Calculation (based upon any changes to the erosion control plan) . If you need
clarification concerning the erosion control section, or if there are any questions
please contact Jesse Schlam 970-218-2932 or email @ jschlam@fcgov.com
08/09/2016: Current Erosion Control Materials Submitted do not meet
requirements. Please submit; Erosion Control Plan (based on redlined comments),
Erosion Control Report (based on redline comments), and an Escrow / Security
Calculation (based upon any changes to the erosion control plan) . If you need
clarification concerning the erosion control section, or if there are any questions
please contact Jesse Schlam 970-218-2932 or email @ jschlam@fcgov.com
Comment Number: 12 Comment Originated: 08/09/2016
Department: Technical Services
Contact: Jeff County, 970-221-6588, jcounty@fcgov.com
Topic: Building Elevations
11/22/2016: There are line over text issues. See redlines.
08/08/2016: There are line over text issues. See redlines.
Comment Number: 6 Comment Originated: 08/08/2016
Topic: Construction Drawings
11/22/2016: Please change the name in the title block to match the main title on all
sheets. See redlines.
08/09/2016: Please change the name to "Beebe Christian School".
Comment Number: 8 Comment Originated: 08/09/2016
11/22/2016: We acknowledge your response. A benchmark statement must be
added based on NAVD88 in the EXACT format shown below.
PROJECT DATUM: NAVD88
BENCHMARK # w/ DESCRIPTION
ELEVATION:
BENCHMARK # w/ DESCRIPTION
ELEVATION:
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM.
SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR
THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE
FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88
- X.XX’.
08/09/2016: We did not see any benchmarks or benchmark statement shown on
the plans.
Comment Number: 9 Comment Originated: 08/09/2016
11/22/2016: Some of the sheet titles & sheet numbers in the index do not match the
sheet titles on the noted sheets.
08/09/2016: Some of the sheet titles in the sheet index do not match the sheet titles
on the noted sheets.
Comment Number: 10 Comment Originated: 08/09/2016
Page 9 of 12
11/23/2016: There are line over text issues. See redlines.
08/09/2016: There are line over text issues. See redlines.
Comment Number: 11 Comment Originated: 08/09/2016
11/23/2016: There is text that needs to be masked. Mask all text in hatched areas.
See redlines.
08/09/2016: There is text that needs to be masked. Mask all text in hatched areas.
See redlines.
Comment Number: 12 Comment Originated: 08/09/2016
11/23/2016: This has been addressed.
08/09/2016: There is text that needs to be rotated 180 degrees. See redlines.
Comment Number: 13 Comment Originated: 08/09/2016
11/23/2016: Please clean up the fuzzy text in the Outlet Structure detail on sheet 7.
See redlines.
Comment Number: 17 Comment Originated: 11/23/2016
Topic: Lighting Plan
11/22/2016: This has not been corrected.
08/08/2016: Please change the name to "Beebe Christian School".
Comment Number: 7 Comment Originated: 08/08/2016
11/22/2016: Please change the title in the title block as marked. See redlines.
Comment Number: 16 Comment Originated: 11/22/2016
Topic: Site Plan
11/22/2016: Please add a metes & bounds description of the portion of Tract A that
this project is located. We suggest consulting with a Land Surveyor for this.
08/08/2016: Please include in the legal description the Metes & Bounds description
of the "portion" of Outlot A.
Comment Number: 1 Comment Originated: 08/08/2016
11/22/2016: Some of the sheet titles in the sheet index do not match the sheet titles
on the noted sheets. See redlines.
Comment Number: 14 Comment Originated: 11/22/2016
11/22/2016: There are some sheets missing from the sheet index.
Comment Number: 15 Comment Originated: 11/22/2016
Department: Traffic Operation
Contact: Nicole Hahn, 970-221-6820, nhahn@fcgov.com
Topic: Traffic Impact Study
08/09/2016: Operational analysis for school drop off and pick up will need to be
provided with next submittal.
11/22/2016: Analysis has been provided and the conclusions accepted.
Comment Number: 1 Comment Originated: 08/09/2016
Department: Water Conservation
Contact: Eric Olson, 970-221-6704, eolson@fcgov.com
Topic: General
Page 10 of 12
08/08/2016: Irrigation plans are required no later than at the time of building permit.
The irrigation plans must comply with the provisions outlined in Section 3.2.1(J) of
the Land Use Code. Direct questions concerning irrigation requirements to Eric
Olson, at 221-6704 or eolson@fcgov.com
Comment Number: 1 Comment Originated: 08/08/2016
Department: Water-Wastewater Engineering
Contact: Heather McDowell, 970-224-6065, hmcdowell@fcgov.com
Topic: General
11/22/2016: Utility Plan – For the proposed water service, please show the meter
vault to scale. (Final)
08/08/2016: Utility Plan ¿ For the proposed water service, please show the
proposed curb stop and water meter to scale and place them according to our
standard details.
Comment Number: 2 Comment Originated: 08/08/2016
11/22/2016: Utility Plan – please include the roof drains and storm pipes on this
utility plan. (Final)
Comment Number: 8 Comment Originated: 11/22/2016
11/22/2016: Utility Plan – it looks as though there are several notes on this page that
are from another jurisdiction. Please remove all notes that do not specifically pertain
to the City of Fort Collins. See redlined comments. (Final)
Comment Number: 9 Comment Originated: 11/22/2016
11/22/2016: Utility Plan – Add a note regarding the abandonment of existing water or
sewer services at the main. Contractor to coordinate with City of Fort Collins Field
Operations for water or sewer line abandonment procedures during construction at
(970) 221-6700. Also please add a note that reuse of the hydrant will be verified at
the time of construction with CoFC Field Operations. (Final)
Comment Number: 10 Comment Originated: 11/22/2016
Topic: Landscape Plans
11/22/2016: Landscape Plan – Please show the relocated hydrant on Joseph Allen
Drive. You may need to shift a tree to provide 10-feet of separation from the hydrant.
Please also check the separation between the relocated hydrant on Nancy Gray and
the closest tree. (Prelim)
Comment Number: 11 Comment Originated: 11/22/2016
11/22/2016: Landscape Plan – please ensure 6’ of separation between the water
and sewer services and the proposed trees along Joseph Allen Drive parking lot
frontage. (Prelim)
Comment Number: 12 Comment Originated: 11/22/2016
11/22/2016: Landscape Plan – please relabel the water quality ponds as rain
gardens. (Prelim)
Comment Number: 13 Comment Originated: 11/22/2016
11/22/2016: Landscape Plan - a portion of the existing detention pond is going to
have to be regraded, please remove the label on the detention pond that says “to be
left undisturbed”. (Prelim)
Comment Number: 14 Comment Originated: 11/22/2016
11/22/2016: Landscape Plan – I think the scale label is incorrect. (Prelim)
Comment Number: 15 Comment Originated: 11/22/2016
Department: Zoning
Page 11 of 12
Contact: Noah Beals, 970-416-2313, nbeals@fcgov.com
Topic: General
11/21/2016: The sidewalk connection to the main door needs to enhanced and
moved closer to the door.
Comment Number: 12 Comment Originated: 11/21/2016
11/21/2016: The sidewalk along the north maybe redundant. Possibly consider a
connection to the sidewalk on the property to the north.
Comment Number: 13 Comment Originated: 11/21/2016
11/21/2016: The handicap parking spaces do not have to be bunched together.
Comment Number: 14 Comment Originated: 11/21/2016
11/21/2016: The ramp for the handicap spaces do not have a landing.
Comment Number: 15 Comment Originated: 11/21/2016
11/21/2016: The lighting levels are low in the drive aisle on the south side of the
building.
Comment Number: 16 Comment Originated: 11/21/2016
11/21/2016: The trash enclosure's walk-in access is not clear on the plans.
Comment Number: 17 Comment Originated: 11/21/2016
Contact: Ryan Boehle, 970-416-2401, rboehle@fcgov.com
Topic: General
To establish "build-to" lines, buildings shall be located and designed to align or
approximately align with any previously established building/sidewalk relationships
that are consistent with this standard. Buildings shall be located no more than fifteen
(15) feet from the right-of-way of an adjoining street if the street is smaller than a full
arterial or has on-street parking.
Comment Number: 2 Comment Originated: 08/09/2016
Site lighting needs to be provided as per 3.2.4 (C), a lighting plan, including
photometrics and fixture cut sheets.
Comment Number: 7 Comment Originated: 08/10/2016
3.5.1(I)(6) All mechanical equipment, meters, conduit, vents and RTU’s shall be
screened from public view both from above and below by integrating it into the
building and roof design.
Comment Number: 9 Comment Originated: 08/10/2016