HomeMy WebLinkAboutWORTHINGTON AVENUE RESIDENCES - PDP - PDP160023 - REPORTS - CITY STAFF1
Worthington Avenue Residences
Clay Frickey
10-13-2016
Project Overview
• 8.15 acre site
• 34 units
• 17 buildings
• 55-65 community
• Employment (E)
Zone District
• 2 modification
requests
Modification #1 – 4.27(D)(2)
All secondary uses shall be integrated both in function and appearance
into a larger employment district development plan that emphasizes
primary uses. A secondary use shall be subject to administrative review
or Planning and Zoning Board review as required for such use in
Section 4.27(B). The following permitted uses shall be considered
secondary uses in this zone district and together shall occupy no
more than twenty-five (25) percent of the total gross area of the
development plan…(d) Residential uses (except mixed-use
dwellings when the residential units are stacked above a primary
use which occupies the ground floor).
Staff Findings – Modification #1
• Use supports primary uses
• Health care providers
• Helps fulfill community wide need
• Growing senior population
• Double by 2030
Modification #2 – 4.27(D)(5)
All residential development in the E Employment District shall have an
overall minimum average density of seven (7) dwelling units per
net acre of residential land.
Staff Findings – Modification #2
• Ranch style better
serves residents
• Fits context
Recommendation
Staff recommends that the Planning & Zoning Board make a motion to
approve Worthington Avenue Residences, PDP160023 based on the
findings of fact found on page 17 of the staff report.
WORTHINGTON CIRCLE
NEW MERCER DITCH
LARIMER CANAL NO. 2
92,270 S.F.
ALL SHRUB BEDS TO RECEIVE A MINIMUM 4"-6" DEPTH
SHREDDED CEDAR WOOD MULCH
SHREDDED CEDAR MULCH
14,880 S.F.
NON-IRRIGATED PRAIRIE MEADOW GRASS MIX
STEEL EDGER, ROUNDED TOP
NATURAL HABITAT BUFFER
PLEASE SEE SECTION 3.4.1 OF
THE LAND USE CODE FOR
ALLOWABLE USES WITHIN THE
NATURAL HABITAT BUFFER
ZONE.
60,871 S.F.
DURA-TURF FESCUE BLEND SEED
IRRIGATED TURF
NOTES:
1. PLEASE SEE SECTION 3.4.1 OF THE
LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NATURAL HABITAT
BUFFER ZONE. THE NATURAL HABITAT
BUFFER ZONE IS INTENDED TO BE
MAINTAINED IN A NATIVE LANDSCAPE.
Sheet Number:
Fort Collins, CO
Worthington
Avenue
Residences
GROUP
landscape architecture|planning|illustration
444 Mountain Ave.
Behtroud,CO 80513
TEL
WEB
970.532.5891
TBGroup.us
PROJECT TITLE
REVISIONS
ISSUE DATE
SHEET TITLE
SHEET INFORMATION
DATE
SEAL
8-9-16
DATE
PREPARED FOR
Columbine Health
Systems
802 West Drake Road
Suite 101
Fort Collins CO 80525
2
Landscape Plan
SCALE 1" = 40'-0"
0 40' 60' 80'
NORTH
Landscape Plan
THAN FINISH GRADE / IRRIGATION TREE WELL TO BE PROVIDED
OPEN BURLAP AROUND TRUNK.
CUT & REMOVE TOP 1/3 OF BURLAP
GROUND COVER & SHRUB PLANTING DETAIL
BACKFILL W/ 2/3 NATIVE SOIL
& 1/3 COMPOST. THOROUGHLY
WATER SETTLE
SLOW RELEASE FERTILIZER TABLET (TYP.)
3" MIN.
3"
AWAY FROM FOLIAGE
SECTION
EXISTING
SOIL
FOR SHRUBS
THAN DIA. OF
TO BE 6" LARGER
PLANTING HOLE
ROOTBALL FOR
DIA. OF ROOTBALL
12" LARGER THAN
GROUNDCOVER.
KEEP MULCH LAYER
FINISH GRADE
TOP OF ROOT CROWN TO BE 1"
HIGHER THAN FINISH GRADE
CEDAR MULCH RING TO BE TWICE
DIAMETER OF ROOT BALL - 2" DEPTH
MULCH - SEE NOTES - 5" DEPTH
MAXIMUM
TRUNK
TREE
3" MULCH
12" MIN.
SECTION
12" MIN.,
TYP.
NOTE:
CEDAR MULCH
TREE RING SHALL
BE 36" DIA.
BACKFILL W/ 2/3 NATIVE SOIL & 1/3
COMPOST. THOROUGHLY WATER
SETTLE
TIE GROMMETED NYLON STRAPS TO STAKE WITH WIRE. WIRE
ENDS SHALL BE BENT BACK TO ELIMINATE BURRS AND WHITE PVC
PIPE ALONG ENTIRE LENGTH OF WIRE FOR VISUAL AND SAFETY
TOP OF ROOT CROWN TO BE 1" HIGHER
EXISTING SOIL
SLOW RELEASE FERTILIZER TABLET (TYP.)
DRIVE TWO (2) WOOD STAKES PER
TREE.
REMOVE WIRE CAGE AND/OR TWINE. OPEN BURLAP
AROUND TRUNK. CUT & REMOVE TOP 1/3 OF BURLAP
PLAN
THAN DIA. OF
24" GREATER
ROOTBALL
FINISH GRADE
T-POST
5047.09
5046.75
5041.49
GRASS
GRASS
GRASS
GRASS
GRAVEL
GRAVEL
ASPHALT
"PET WASTE"
300
5047.56
CP-SPRING
SET #4 REBAR WITH
2" ALUMINUM CAP
N=1446455.28
E=3114287.67
VERTICAL CURB
& GUTTER
RIVER ROCK
CONC WALL
RIVER ROCK
13 AC UNITS
TRASH ENCLOSURE
VERTICAL CURB
CONCRETE PAN
CONCRETE WALL
CONCRETE DRAINAGE STRUCTURE
CONCRETE WALL
WORTHINGTON
CIRCLE
NEW MERCER
DITCH
LARIMER CANAL
SMH W
RIM=5047.3
INV (NW)=5036.9
INV (SE)=5036.8
15" RCP
FL=5040.9
21"X36" RCP
FL=5044.5
18" PIPE
FL=5041.2
15" RCP
FL=5042.2
15" CPP
FL=5045.1
INLET AREA INLET
CONCRETE DRAINAGE STRUCTURE
12" PVC
FL=5042.3
S
W
O
ET
E
T
T
R2 R1
W3
W1
W3
W5
W1
W5
W3
W2
W1
10
4
Roof Peak
121' - 10"
1 W1 1 11 1 W3 W1 1 W3 11 6 1 1
4
3
4
R1
W3
7 10 3 9 10 4 3
4
6" 10
12"
6"
12"
6"
12"
R1
R2
W5
W5
W5
W5
W3
W1 W1 W3 W1
W3
W1
10
10
3 10 3 10 3 10 10
10
3
Roof Peak
121' - 10"
1 8 2 8 10 5 10 8 1 2 8 10 5
6
4
6"
12"
3
R1
6"
12"
6"
12"
1
6"
12"
6"
T.O. Sub Floor
100' - 0"
Plate Height
109' - 1 1/8"
R1 R1 R2
R1
R1
R1
R2
W3
W6
W4
W3 W6 W6
W4 W4 W6
W3 W6 W6 W3 W3 W6
W4
11 2 1 5 1 2
1
6
4
7 1 7
8 6 8 8 8
8
3 1/2"
12"
3 1/2"
12"
T.O. Ridge
119' - 9 5/8"
13 12 13 13 13
T.O. Sub Floor
100' - 0"
Plate Height
109' - 1 1/8"
W6 R2 R1
R1
W5 R1 W6
W4
W3
W3 W6 W6 W3 W6 W6
W3
W6
R1
W6
4
1 11
7 10 7 10
4
6 6 1 6 1 1
4 11 1 6
3 1/2"
12" 3 1/2"
12"
T.O. Ridge
119' - 9 5/8"
3 of 6
5
3 of 6
3
3 of 6
SHOWER
PAN
SHOWER
PAN
SHOWER
PAN
Roof Peak
119' - 5"
W1
W3
R1
W5
W1 W3 W1
4
1 W3 1 W1 4 1 6 6 W3 1 W1 6 1 6 11 1 6 4 1
4
10
3
W1
W3
W5
R1 10 R2 4 W5 9 10 W2 7 R1
5"
12"
5"
12"
5"
12"
5"
12"
5"
12"
Roof Peak
119' - 5"
W1
W3
R2
W5 R1
1 W1 2 6 1
4
6
1 6 2 8 5 8 5 8
4
6
W3 6 W1
4
3
R1 R1 7 W2 R2 W5 10 9 10 3 W5 R1
4 4
1 10
5"
12"
5"
12"
5"
12"
5"
12"
5"
12"
SHOWER
PAN
SHOWER
PAN
R1 R2 R1 W6 R1 R2 W6
W5
W3
W6 W6 W3 W6 W5 W6 W5
R1
W3
7 3
3
4
6
6
1 4 6 W6 1 W3 W6
4
1 10
7 10 3
10 10
3 3 4
4
1 10 66 1
4
4 4
T.O. Ridge
3 1/2" 121'-3 1/2"
12"
3 1/2"
12"
6"
12" 6"
12"
6"
12"
6"
12"
1 3/4"
12"
R1 R1
R2
W5 R2 R1 W5
W3
W6 W6
W6
W3
10 1 W3 3 10 3
4
10
8
4 1 6 2 8 1 W3 8 10 5
3 10
W3 W6 2 10 8 5 5 10 8 W3
4
1 8
3
3 T.O. Ridge
121'-3 1/2"
6"
12"
T.O. Ridge
119'-4"
R2 W3 W6 R2
W3
W6
W4 W6 W3
W4 W6 R2
W6
R1
9 3 7
4
1 1 11 1 1 1 1 11 1 1
4
4
3 9 6 7 10
6 6 4 6 6
6 4
33
4
5"
12"
5"
12"
5"
12"
5"
12"
5"
12"
T.O. Ridge
119'-4"
W4 W4 W4 W4
W3
W6
W6 W4 W6 W3 W3 W6
W3
R1
R2
7 W6 9 R2 4 7 W6 3 9 R2
10
3
4
4
5 2 1 5
4
6
2 1 4 4
3
33
6
3
3
6
6 8 8
8
8 8 8
5"
5" 12"
12"
5"
12"
5"
12"
5"
12"
5"
12"
5"
12"
13 12 13 13 12 13
W4 W6 R1
R1
W6
W4
W6 1 W6 1 W3
7 3 3
4
66
4 4 4 1 66
3
4
T.O. Ridge
119'-4"
5"
12"
3 1/2"
5" 12"
12"
13
Building elevation is located parallel to adjacent
building and is not visible from surrounding areas.
T.O. Ridge
119' - 4"
3 R2 7 10 W6 R1
3
44
W3 W6
W4
4
6
6
4
3
5"
12"
13
Building elevation is located parallel to adjacent
building and is not visible from surrounding areas.
6 of 6
3
6 of 6
6
6 of 6
5
6 of 6
4
Adjacent Home on the
same lot, refer to sheet
ARCH 1 of 6
Adjacent Home on the
same lot, refer to sheet
ARCH 1 of 6
86' - 4"
= 10.4% of Frontage
9' - 0"
= 10.4% of Frontage
9' - 0"
14'Patio - 8" Patio 14' - 7 1/2"
13
12 13
4' - 1"
4' - 1"
13 12 13
Compliance per MuniCode 3.5.2(F)
• Streets lined with active living spaces at each
entry with oversized patio that extends 4'-0"
minimum from the face of the garage.
• Pedestrian-oriented streetscapes throughout the
development
• Enhances visual interest in the exterior building
design includes masonry and metal railings
along the front of each patio with enhanced
landscaping.
• Total garage door frontage = 18'-0" (20.8%)
Extents of roof
overhang, Typical.
Extents of roof
overhang, Typical.
Issued
Drawing Number
Scale Accordingly if Reduced
Project No.: Drawn by:
Reviewed by:
In Association with:
ARCHITECTS
r4 architects.com
226 Remington
Unit #3
Fort Collins, CO 80524
phone 970/224-0630
www.r4architects.com
PDF Review
ARCH
1 PDP Submittal 08/09/2016
Contact: Blake Larsen
Email: blake@larsensd.com
Larsen Structural Design
Phone: (970) 568-3355
Fort Collins, CO 80524
19 Old Town Square, Suite 238
Structural Engineer
Contact: Tom Segelhorst
Email: Thomas-s@int-mech.com
Integrated Mechanical
Phone: (970)556-0570
Fort Collins, CO 80524
223 Linden St. Suite 204
Mech/Plumbing Engineer
Contact: Chuck Polson
Email: chuck@apsinc.biz
APS, Inc.
Phone: (970) 381-7462
Highlands Ranch, CO 80129
9249 S. Broadway, #200-836
Electrical Engineer
Contact: Mike Oberlander
Email: moberlander@Interwestgrp.com
Interwest Consulting Group
Phone: (970)674-3300
Windsor, CO 80550
1218 Ash Street
Civil Engineer
Contact: Cathy Mathis & Jim Doyle
Email: cathy@tbgroup.us, doyle@tbgroup.us
TB Group
Phone: (970)532-5891
Berthoud, CO 80531
444 Mountain Avenue
Planning & Landscape
Contact: Tyler Texeira
Email: Tyler@Beacon-Con.com
Columbine Health Systems
Phone: (970)566-1432
Fort Collins, CO 80527
PO Box 270218
Owner
Contact: Tyler Texeira
Email: Tyler@Beacon-Con.com
Beacon Construction
Phone: (970)566-1432
Fort Collins, CO 80527
PO Box 270218
General Contractor
2 PDF Review 09/19/2016
SA, JDO
MR
Building Elevations
Building Type; DD
Fort Collins, CO 80526
2014-15
Columbine
Residences
6 of 6
1/8" = 1'-0"
5
Backyard Elevation
1/8" = 1'-0"
3
Street Front Elevation
Materials Legend
Modular Brick Veneer, field
Stone Veneer
Horizontal Siding
Shingle Siding
Direct Applied Thin Brick
Standard size brick - running bond
3/4" Thick color to match Modular Brick
Veneer - running bond
Thin stone veneer, field stone pattern
James Hardie Lap Siding
James Hardie: HardieShingle Siding,
Staggered Edge Panel
Pattern Material Name Material Description
W1
W2
W6
W3
W5
W4Siding Board & Batten Siding Board and Batten
R1 Roofing High profile asphalt shingles
1
Fixed or opperable window
unit
Basis of Design:
Anderson 100 Series, Colors: TBD
3
Main Entry Door
Basis of Design:
Masonite Barrington Craftsman Series,
Color: TBD
Keynote Legend
2
4
Roof Fascia
Fascia trim board painted,
Colors: TBD
5
Gutter & Downspout
Pre-finished metal, gutters and downspouts to
match fascia trim color.
6
Sectional Garage Door
Sectional garage door
Colors: TBD
7
8
Exposed Glulam Structure
Glulam structure stained,
Colors: TBD
Fireplace Cap
Gas fireplace round termination cap, Prefinished
Color: TBD
Keynote Keynote Item Description
Color TBD
Material Color / Finish
Basis of Design
Eldorado Stone: Country Rubble; Color: TBD
Exterior Light Fixture
Exterior wall sconce, Light fixture controlled by
individual tenant. Color: TBD
Basis of Design
Owens Corning: Duration Series - Color TBD
Color TBD
Basis of Design: HardiePlank Lap Siding, 4" exposure
Color TBD, Finish: smooth
Basis of Design: HardieShingle Siding,
Staggered Edge Panel
Color TBD, Finish: Cedar Mill
Basis of Design: HardiePanel Siding, w/ HardieTrim
Batten Boards @ 12' o.c.
Color TBD, Finish: smooth
R2 Roofing Standing seam metal roofing
Basis of Design
Berridge Manufacturing, CEE-LOCK, Color TBD
9 Gable end vent Vent will be square or pitched to match roof
10 Glulam lookout & knee
brace
Glulam structure stained,
Colors: TBD
Keynote Keynote Item Description
11 Patio doors
Basis of Design:
to match Anderson 100 Series, Colors: TBD
12 Fence/Railing Prefinished metal fence/railing, 30" high
13 Fence Post/Column Base
Masonry corner fence post to match adjacent column base w/
precast concrete cap, 36" high.
14 Electrical Gear Electrical meter and gear as specified by electrical drawings
1/8" = 1'-0"
4
Left Side Elevation
1/8" = 1'-0"
6
Right Side Elevation
2
Building DD - 3D Street View
1/16" = 1'-0"
1
Building DD Planning Floor Plan
No. Description Date
1
6"
12"
3 1/2"
12"
3 1/2"
12"
6"
12"
6"
12"
13 12 13
6
13
13
W6 R1 R2 W5 R1 W5 R1
W3 W3 W6 W3
W6
7
3
4
6
1 66 11 44 1
3
8
4
4
2 1/2"
12"
5"
12"
5"
12"
5"
12"
2 1/2"
4 1/4" 12"
12"
2 1/2"
12"
T.O. Ridge
121'-3 1/2"
6
13
Building elevation is located parallel to adjacent
building and is not visible from surrounding areas.
R1 R1 W5 R1
W6 W3
W3
W6
33 9 9
6
11
6
4
4
1 1
8
44
10
4 3
T.O. Ridge
121'-3 1/2"
5"
12"
4 1/4"
12"
4 1/4"
12"
2 1/2"
12"
5"
12"
13
Building elevation is located parallel to adjacent
building and is not visible from surrounding areas.
5 of 6
3
5 of 6
6
5 of 6
5 of 6
5
4
Adjacent Home on the
same lot, refer to sheet
ARCH 1 of 6
Adjacent Home on the
same lot, refer to sheet
ARCH 1 of 6
91' - 0 1/2"
20' - 6" Patio 26' - 11 1/2" Patio
= 21.4% of Frontage
19' - 6"
= 17.6% of Frontage
16' - 0"
6' - 0"
13 12 13
5' - 8 1/2"
13 13
6
Area covered by a
wood Pergola
Extents of roof
overhang, Typical.
Extents of roof
overhang, Typical.
Compliance per MuniCode 3.5.2(F)
• Streets lined with active living spaces at each
entry with oversized patio that extends 4'-0"
minimum from the face of the garage.
• Pedestrian-oriented streetscapes throughout
the development
• Enhances visual interest in the exterior
building design includes masonry and metal
railings along the front of each patio with
enhanced landscaping. A wood pergola is
provided over one entry to extend the patio
cover accordingly.
• Total garage door frontage = 35'-6" (39.0%)
Issued
Drawing Number
Scale Accordingly if Reduced
Project No.: Drawn by:
Reviewed by:
In Association with:
ARCHITECTS
r4 architects.com
226 Remington
Unit #3
Fort Collins, CO 80524
phone 970/224-0630
www.r4architects.com
PDF Review
ARCH
1 PDP Submittal 08/09/2016
Contact: Blake Larsen
Email: blake@larsensd.com
Larsen Structural Design
Phone: (970) 568-3355
Fort Collins, CO 80524
19 Old Town Square, Suite 238
Structural Engineer
Contact: Tom Segelhorst
Email: Thomas-s@int-mech.com
Integrated Mechanical
Phone: (970)556-0570
Fort Collins, CO 80524
223 Linden St. Suite 204
Mech/Plumbing Engineer
Contact: Chuck Polson
Email: chuck@apsinc.biz
APS, Inc.
Phone: (970) 381-7462
Highlands Ranch, CO 80129
9249 S. Broadway, #200-836
Electrical Engineer
Contact: Mike Oberlander
Email: moberlander@Interwestgrp.com
Interwest Consulting Group
Phone: (970)674-3300
Windsor, CO 80550
1218 Ash Street
Civil Engineer
Contact: Cathy Mathis & Jim Doyle
Email: cathy@tbgroup.us, doyle@tbgroup.us
TB Group
Phone: (970)532-5891
Berthoud, CO 80531
444 Mountain Avenue
Planning & Landscape
Contact: Tyler Texeira
Email: Tyler@Beacon-Con.com
Columbine Health Systems
Phone: (970)566-1432
Fort Collins, CO 80527
PO Box 270218
Owner
Contact: Tyler Texeira
Email: Tyler@Beacon-Con.com
Beacon Construction
Phone: (970)566-1432
Fort Collins, CO 80527
PO Box 270218
General Contractor
2 PDF Review 09/19/2016
SA
MR
Building Elevations
Building Type; CE
Fort Collins, CO 80526
2016-11
Columbine
Residences
5 of 6
1/8" = 1'-0"
5
Backyard Elevation
1/8" = 1'-0"
3
Street Front Elevation
Materials Legend
Modular Brick Veneer, field
Stone Veneer
Horizontal Siding
Shingle Siding
Direct Applied Thin Brick
Standard size brick - running bond
3/4" Thick color to match Modular Brick
Veneer - running bond
Thin stone veneer, field stone pattern
James Hardie Lap Siding
James Hardie: HardieShingle Siding,
Staggered Edge Panel
Pattern Material Name Material Description
W1
W2
W6
W3
W5
W4Siding Board & Batten Siding Board and Batten
R1 Roofing High profile asphalt shingles
1
Fixed or opperable window
unit
Basis of Design:
Anderson 100 Series, Colors: TBD
3
Main Entry Door
Basis of Design:
Masonite Barrington Craftsman Series,
Color: TBD
Keynote Legend
2
4
Roof Fascia
Fascia trim board painted,
Colors: TBD
5
Gutter & Downspout
Pre-finished metal, gutters and downspouts to
match fascia trim color.
6
Sectional Garage Door
Sectional garage door
Colors: TBD
7
8
Exposed Glulam Structure
Glulam structure stained,
Colors: TBD
Fireplace Cap
Gas fireplace round termination cap, Prefinished
Color: TBD
Keynote Keynote Item Description
Color TBD
Material Color / Finish
Basis of Design
Eldorado Stone: Country Rubble; Color: TBD
Exterior Light Fixture
Exterior wall sconce, Light fixture controlled by
individual tenant. Color: TBD
Basis of Design
Owens Corning: Duration Series - Color TBD
Color TBD
Basis of Design: HardiePlank Lap Siding, 4" exposure
Color TBD, Finish: smooth
Basis of Design: HardieShingle Siding,
Staggered Edge Panel
Color TBD, Finish: Cedar Mill
Basis of Design: HardiePanel Siding, w/ HardieTrim
Batten Boards @ 12' o.c.
Color TBD, Finish: smooth
R2 Roofing Standing seam metal roofing
Basis of Design
Berridge Manufacturing, CEE-LOCK, Color TBD
9 Gable end vent Vent will be square or pitched to match roof
10 Glulam lookout & knee
brace
Glulam structure stained,
Colors: TBD
Keynote Keynote Item Description
11 Patio doors
Basis of Design:
to match Anderson 100 Series, Colors: TBD
12 Fence/Railing Prefinished metal fence/railing, 30" high
13 Fence Post/Column Base
Masonry corner fence post to match adjacent column base w/
precast concrete cap, 36" high.
14 Electrical Gear Electrical meter and gear as specified by electrical drawings
1/8" = 1'-0"
4
Left Side Elevation
1/8" = 1'-0"
6
Right Side Elevation
2
Building CE - 3D Street View
1/16" = 1'-0"
1
Building CE Planning Floor Plan
No. Description Date
1 3/4"
12"
13
W1 13 12 13 13 12
W3 W1
W5
R1
W3 W1
W2 R1 W5
W1
1 4 1
4
3
7
1
10 10 9 W5 3 R2
5"
12"
1 3/4"
5" 12"
5" 12"
12"
8
4
3
6 8 6 4
Roof Peak
119' - 5"
13
Building elevation is located parallel to adjacent
building and is not visible from surrounding areas.
Roof Peak
119' - 5"
4
6
4
4 6 W1 8 W3 W1 1 1 W3 1 W1 4
8
W1
R1
W5
R1 W5 R1 R1 R1 W2
R1
10 9 10 10 7
2 1/2"
12"
5"
12"
5"
12"
13
Building elevation is located parallel to adjacent
building and is not visible from surrounding areas.
*Provide transom window in unit #26 only.
4 of 6
3
4 of 6
6
4 of 6
4 of 6
5
4
Adjacent Home on the
same lot, refer to sheet
ARCH 1 of 6
Adjacent Home on the
same lot, refer to sheet
ARCH 1 of 6
88' - 9"
= 10.1% of Frontage
9' - 0"
27' - 0" Patio 18' - 5 1/2" Patio
12
13
13
4' - 1"
4' - 1"
Compliance per MuniCode 3.5.2(F)
• Streets lined with active living spaces at each
entry with oversized patio that extends 4'-0"
minimum from the face of the garage.
• Pedestrian-oriented streetscapes throughout
the development
• Enhances visual interest in the exterior building
design includes masonry and metal railings
along the front of each patio with enhanced
landscaping.
• Total garage door frontage = 25'-0" (28.1%)
Extents of roof
overhang, Typical.
Extents of roof
overhang, Typical.
13
= 18.0% of Frontage 13 12
16' - 0"
Issued
Drawing Number
Scale Accordingly if Reduced
Project No.: Drawn by:
Reviewed by:
In Association with:
ARCHITECTS
r4 architects.com
226 Remington
Unit #3
Fort Collins, CO 80524
phone 970/224-0630
www.r4architects.com
PDF Review
ARCH
1 PDP Submittal 08/09/2016
Contact: Blake Larsen
Email: blake@larsensd.com
Larsen Structural Design
Phone: (970) 568-3355
Fort Collins, CO 80524
19 Old Town Square, Suite 238
Structural Engineer
Contact: Tom Segelhorst
Email: Thomas-s@int-mech.com
Integrated Mechanical
Phone: (970)556-0570
Fort Collins, CO 80524
223 Linden St. Suite 204
Mech/Plumbing Engineer
Contact: Chuck Polson
Email: chuck@apsinc.biz
APS, Inc.
Phone: (970) 381-7462
Highlands Ranch, CO 80129
9249 S. Broadway, #200-836
Electrical Engineer
Contact: Mike Oberlander
Email: moberlander@Interwestgrp.com
Interwest Consulting Group
Phone: (970)674-3300
Windsor, CO 80550
1218 Ash Street
Civil Engineer
Contact: Cathy Mathis & Jim Doyle
Email: cathy@tbgroup.us, doyle@tbgroup.us
TB Group
Phone: (970)532-5891
Berthoud, CO 80531
444 Mountain Avenue
Planning & Landscape
Contact: Tyler Texeira
Email: Tyler@Beacon-Con.com
Columbine Health Systems
Phone: (970)566-1432
Fort Collins, CO 80527
PO Box 270218
Owner
Contact: Tyler Texeira
Email: Tyler@Beacon-Con.com
Beacon Construction
Phone: (970)566-1432
Fort Collins, CO 80527
PO Box 270218
General Contractor
2 PDF Review 09/19/2016
JDO, SA
MR
Building Elevations
Building Type: BE
Fort Collins, CO 80526
2016-11
Columbine
Residences
4 of 6
1/8" = 1'-0"
5
Backyard Elevation
1/8" = 1'-0"
3
Street Front Elevation
Materials Legend
Modular Brick Veneer, field
Stone Veneer
Horizontal Siding
Shingle Siding
Direct Applied Thin Brick
Standard size brick - running bond
3/4" Thick color to match Modular Brick
Veneer - running bond
Thin stone veneer, field stone pattern
James Hardie Lap Siding
James Hardie: HardieShingle Siding,
Staggered Edge Panel
Pattern Material Name Material Description
W1
W2
W6
W3
W5
W4Siding Board & Batten Siding Board and Batten
R1 Roofing High profile asphalt shingles
1
Fixed or opperable window
unit
Basis of Design:
Anderson 100 Series, Colors: TBD
3
Main Entry Door
Basis of Design:
Masonite Barrington Craftsman Series,
Color: TBD
Keynote Legend
2
4
Roof Fascia
Fascia trim board painted,
Colors: TBD
5
Gutter & Downspout
Pre-finished metal, gutters and downspouts to
match fascia trim color.
6
Sectional Garage Door
Sectional garage door
Colors: TBD
7
8
Exposed Glulam Structure
Glulam structure stained,
Colors: TBD
Fireplace Cap
Gas fireplace round termination cap, Prefinished
Color: TBD
Keynote Keynote Item Description
Color TBD
Material Color / Finish
Basis of Design
Eldorado Stone: Country Rubble; Color: TBD
Exterior Light Fixture
Exterior wall sconce, Light fixture controlled by
individual tenant. Color: TBD
Basis of Design
Owens Corning: Duration Series - Color TBD
Color TBD
Basis of Design: HardiePlank Lap Siding, 4" exposure
Color TBD, Finish: smooth
Basis of Design: HardieShingle Siding,
Staggered Edge Panel
Color TBD, Finish: Cedar Mill
Basis of Design: HardiePanel Siding, w/ HardieTrim
Batten Boards @ 12' o.c.
Color TBD, Finish: smooth
R2 Roofing Standing seam metal roofing
Basis of Design
Berridge Manufacturing, CEE-LOCK, Color TBD
9 Gable end vent Vent will be square or pitched to match roof
10 Glulam lookout & knee
brace
Glulam structure stained,
Colors: TBD
Keynote Keynote Item Description
11 Patio doors
Basis of Design:
to match Anderson 100 Series, Colors: TBD
12 Fence/Railing Prefinished metal fence/railing, 30" high
13 Fence Post/Column Base
Masonry corner fence post to match adjacent column base w/
precast concrete cap, 36" high.
14 Electrical Gear Electrical meter and gear as specified by electrical drawings
1/8" = 1'-0"
4
Left Side Elevation
1/8" = 1'-0"
6
Right Side Elevation
1/16" = 1'-0"
1
Building BE Planning Floor Plan
2
Building BE - 3D Street View
No. Description Date
4
Adjacent Home on the
same lot, refer to sheet
ARCH 1 of 6
83' - 0" Overall Street Frontage
= 21.7% of Frontage
18' - 0"
Adjacent Home on the
same lot, refer to sheet
ARCH 1 of 6
= 10.8% of Frontage
9' - 0"
17' - 6" Patio 14' - 9 1/2" Patio
Area covered by a
wood Pergola
Extents of roof
overhang, Typical.
Extents of roof
overhang, Typical.
3 of 6
6
Compliance per MuniCode 3.5.2(F)
• Streets lined with active living spaces at each entry
with oversized patio that extends 4'-0" minimum
from the face of the garage.
• Pedestrian-oriented streetscapes throughout the
development
• Enhances visual interest in the exterior building
design includes masonry and metal railings along
the front of each patio with enhanced landscaping.
A wood pergola is provided over one entry to
extend the patio cover accordingly.
• Total garage door frontage = 27'-0" (32.5%)
13 12 13
13 13 6
4' - 1"
4' - 1"
T.O. Sub Floor
100' - 0"
Plate Height
109' - 1 1/8"
W6 R1 W4 R1
W6 W3
R1
1 1 1
4
W3
W6
R1
7 10 7 10
3 1/2"
12"
8
W6 4
T.O. Ridge
119' - 9 5/8"
13
Building elevation is located parallel to adjacent
building and is not visible from surrounding areas.
T.O. Sub Floor
100' - 0"
Plate Height
109' - 1 1/8"
R1 R1
R1
W6
R2
W3 W6
R2 W4
W6 W3 W6 W4
W4
W3
4 1 6 1 1 1
8
3 1/2"
12"
10 7 10 7
4
6
11
W6
T.O. Ridge
119' - 9 5/8"
13
6
Building elevation is located parallel to adjacent
building and is not visible from surrounding areas.
Issued
Drawing Number
Scale Accordingly if Reduced
Project No.: Drawn by:
Reviewed by:
In Association with:
ARCHITECTS
r4 architects.com
226 Remington
Unit #3
Fort Collins, CO 80524
phone 970/224-0630
www.r4architects.com
PDF Review
ARCH
1 PDP Submittal 08/09/2016
Contact: Blake Larsen
Email: blake@larsensd.com
Larsen Structural Design
Phone: (970) 568-3355
Fort Collins, CO 80524
19 Old Town Square, Suite 238
Structural Engineer
Contact: Tom Segelhorst
Email: Thomas-s@int-mech.com
Integrated Mechanical
Phone: (970)556-0570
Fort Collins, CO 80524
223 Linden St. Suite 204
Mech/Plumbing Engineer
Contact: Chuck Polson
Email: chuck@apsinc.biz
APS, Inc.
Phone: (970) 381-7462
Highlands Ranch, CO 80129
9249 S. Broadway, #200-836
Electrical Engineer
Contact: Mike Oberlander
Email: moberlander@Interwestgrp.com
Interwest Consulting Group
Phone: (970)674-3300
Windsor, CO 80550
1218 Ash Street
Civil Engineer
Contact: Cathy Mathis & Jim Doyle
Email: cathy@tbgroup.us, doyle@tbgroup.us
TB Group
Phone: (970)532-5891
Berthoud, CO 80531
444 Mountain Avenue
Planning & Landscape
Contact: Tyler Texeira
Email: Tyler@Beacon-Con.com
Columbine Health Systems
Phone: (970)566-1432
Fort Collins, CO 80527
PO Box 270218
Owner
Contact: Tyler Texeira
Email: Tyler@Beacon-Con.com
Beacon Construction
Phone: (970)566-1432
Fort Collins, CO 80527
PO Box 270218
General Contractor
2 PDF Review 09/19/2016
JDO, SA
MR
Building Elevations
Building Type: AD
Fort Collins, CO 80526
2016-11
Columbine
Residences
3 of 6
1/8" = 1'-0"
3
Street Front Elevation
1/8" = 1'-0"
5
Backyard Elevation
Materials Legend
Modular Brick Veneer, field
Stone Veneer
Horizontal Siding
Shingle Siding
Direct Applied Thin Brick
Standard size brick - running bond
3/4" Thick color to match Modular Brick
Veneer - running bond
Thin stone veneer, field stone pattern
James Hardie Lap Siding
James Hardie: HardieShingle Siding,
Staggered Edge Panel
Pattern Material Name Material Description
W1
W2
W6
W3
W5
W4Siding Board & Batten Siding Board and Batten
R1 Roofing High profile asphalt shingles
1
Fixed or opperable window
unit
Basis of Design:
Anderson 100 Series, Colors: TBD
3
Main Entry Door
Basis of Design:
Masonite Barrington Craftsman Series,
Color: TBD
Keynote Legend
2
4
Roof Fascia
Fascia trim board painted,
Colors: TBD
5
Gutter & Downspout
Pre-finished metal, gutters and downspouts to
match fascia trim color.
6
Sectional Garage Door
Sectional garage door
Colors: TBD
7
8
Exposed Glulam Structure
Glulam structure stained,
Colors: TBD
Fireplace Cap
Gas fireplace round termination cap, Prefinished
Color: TBD
Keynote Keynote Item Description
Color TBD
Material Color / Finish
Basis of Design
Eldorado Stone: Country Rubble; Color: TBD
Exterior Light Fixture
Exterior wall sconce, Light fixture controlled by
individual tenant. Color: TBD
Basis of Design
Owens Corning: Duration Series - Color TBD
Color TBD
Basis of Design: HardiePlank Lap Siding, 4" exposure
Color TBD, Finish: smooth
Basis of Design: HardieShingle Siding,
Staggered Edge Panel
Color TBD, Finish: Cedar Mill
Basis of Design: HardiePanel Siding, w/ HardieTrim
Batten Boards @ 12' o.c.
Color TBD, Finish: smooth
R2 Roofing Standing seam metal roofing
Basis of Design
Berridge Manufacturing, CEE-LOCK, Color TBD
9 Gable end vent Vent will be square or pitched to match roof
10 Glulam lookout & knee
brace
Glulam structure stained,
Colors: TBD
Keynote Keynote Item Description
11 Patio doors
Basis of Design:
to match Anderson 100 Series, Colors: TBD
12 Fence/Railing Prefinished metal fence/railing, 30" high
13 Fence Post/Column Base
Masonry corner fence post to match adjacent column base w/
precast concrete cap, 36" high.
14 Electrical Gear Electrical meter and gear as specified by electrical drawings
1/16" = 1'-0"
1
Building AD Planning Floor Plan
1/8" = 1'-0"
4
Left Side Elevation
1/8" = 1'-0"
6
Right Side Elevation
2
Building AD - 3D Street View
No. Description Date
12"
13 12 13 13 12 13
8
R1
W1
R1
10
Roof Peak
121' - 10"
8 6
8
4
11 W1 1 4 W1 W3 4 1 4
W5
4
3
5"
12"
5"
12"
10 9 R1 W5 4 R1
13
Building elevation is located parallel to adjacent
building and is not visible from surrounding areas.
R1 W3 R1
W1
W5
R1 W5 W2
Roof Peak
121' - 10"
W1 W3 1 1
4
8
3
4 10 9 10 10 7
4
4
W3
3"
12"
5"
12"
5"
12"
3"
12"
13
Building elevation is located parallel to adjacent
building and is not visible from surrounding areas.
2 of 6
3
2 of 6
6
2 of 6
2 of 6
5
4
Adjacent Home on the
same lot, refer to sheet
ARCH 1 of 6
Adjacent Home on the
same lot, refer to sheet
ARCH 1 of 6
Compliance per MuniCode 3.5.2(F)
• Streets lined with active living spaces at each
entry with oversized patio that extends 4'-0"
minimum from the face of the garage.
• Pedestrian-oriented streetscapes throughout
the development
• Enhances visual interest in the exterior building
design includes masonry and metal railings
along the front of each patio with enhanced
landscaping.
• Total garage door frontage = 36'-0" (44.6%)
80' - 10 1/2"
= 22.3% of Frontage
18' - 0"
= 22.3% of Frontage
18' - 0"
17'Patio - 9" Patio 16' - 10 1/2"
4' - 1"
4' - 1"
12' - 7 1/2"
Extents of roof
overhang, Typical.
Extents of roof
overhang, Typical.
12
13 13 13 12 13
Issued
Drawing Number
Scale Accordingly if Reduced
Project No.: Drawn by:
Reviewed by:
In Association with:
ARCHITECTS
r4 architects.com
226 Remington
Unit #3
Fort Collins, CO 80524
phone 970/224-0630
www.r4architects.com
PDF Review
ARCH
1 PDP Submittal 08/09/2016
Contact: Blake Larsen
Email: blake@larsensd.com
Larsen Structural Design
Phone: (970) 568-3355
Fort Collins, CO 80524
19 Old Town Square, Suite 238
Structural Engineer
Contact: Tom Segelhorst
Email: Thomas-s@int-mech.com
Integrated Mechanical
Phone: (970)556-0570
Fort Collins, CO 80524
223 Linden St. Suite 204
Mech/Plumbing Engineer
Contact: Chuck Polson
Email: chuck@apsinc.biz
APS, Inc.
Phone: (970) 381-7462
Highlands Ranch, CO 80129
9249 S. Broadway, #200-836
Electrical Engineer
Contact: Mike Oberlander
Email: moberlander@Interwestgrp.com
Interwest Consulting Group
Phone: (970)674-3300
Windsor, CO 80550
1218 Ash Street
Civil Engineer
Contact: Cathy Mathis & Jim Doyle
Email: cathy@tbgroup.us, doyle@tbgroup.us
TB Group
Phone: (970)532-5891
Berthoud, CO 80531
444 Mountain Avenue
Planning & Landscape
Contact: Tyler Texeira
Email: Tyler@Beacon-Con.com
Columbine Health Systems
Phone: (970)566-1432
Fort Collins, CO 80527
PO Box 270218
Owner
Contact: Tyler Texeira
Email: Tyler@Beacon-Con.com
Beacon Construction
Phone: (970)566-1432
Fort Collins, CO 80527
PO Box 270218
General Contractor
2 PDF Review 09/19/2016
JDO, SA
MR
Building Elevations
Building Type: AA
Fort Collins, CO 80526
2014-15
Columbine
Residences
2 of 6
1/8" = 1'-0"
5
Backyard Elevation
1/8" = 1'-0"
3
Street Front Elevation
Materials Legend
Modular Brick Veneer, field
Stone Veneer
Horizontal Siding
Shingle Siding
Direct Applied Thin Brick
Standard size brick - running bond
3/4" Thick color to match Modular Brick
Veneer - running bond
Thin stone veneer, field stone pattern
James Hardie Lap Siding
James Hardie: HardieShingle Siding,
Staggered Edge Panel
Pattern Material Name Material Description
W1
W2
W6
W3
W5
W4Siding Board & Batten Siding Board and Batten
R1 Roofing High profile asphalt shingles
1
Fixed or opperable window
unit
Basis of Design:
Anderson 100 Series, Colors: TBD
3
Main Entry Door
Basis of Design:
Masonite Barrington Craftsman Series,
Color: TBD
Keynote Legend
2
4
Roof Fascia
Fascia trim board painted,
Colors: TBD
5
Gutter & Downspout
Pre-finished metal, gutters and downspouts to
match fascia trim color.
6
Sectional Garage Door
Sectional garage door
Colors: TBD
7
8
Exposed Glulam Structure
Glulam structure stained,
Colors: TBD
Fireplace Cap
Gas fireplace round termination cap, Prefinished
Color: TBD
Keynote Keynote Item Description
Color TBD
Material Color / Finish
Basis of Design
Eldorado Stone: Country Rubble; Color: TBD
Exterior Light Fixture
Exterior wall sconce, Light fixture controlled by
individual tenant. Color: TBD
Basis of Design
Owens Corning: Duration Series - Color TBD
Color TBD
Basis of Design: HardiePlank Lap Siding, 4" exposure
Color TBD, Finish: smooth
Basis of Design: HardieShingle Siding,
Staggered Edge Panel
Color TBD, Finish: Cedar Mill
Basis of Design: HardiePanel Siding, w/ HardieTrim
Batten Boards @ 12' o.c.
Color TBD, Finish: smooth
R2 Roofing Standing seam metal roofing
Basis of Design
Berridge Manufacturing, CEE-LOCK, Color TBD
9 Gable end vent Vent will be square or pitched to match roof
10 Glulam lookout & knee
brace
Glulam structure stained,
Colors: TBD
Keynote Keynote Item Description
11 Patio doors
Basis of Design:
to match Anderson 100 Series, Colors: TBD
12 Fence/Railing Prefinished metal fence/railing, 30" high
13 Fence Post/Column Base
Masonry corner fence post to match adjacent column base w/
precast concrete cap, 36" high.
14 Electrical Gear Electrical meter and gear as specified by electrical drawings
1/8" = 1'-0"
4
Left Side Elevation
1/8" = 1'-0"
6
Right Side Elevation
1/16" = 1'-0"
1
Building AA Planning Floor Plan
2
Building AA - 3D Street View
No. Description Date
E
T
E
E
Unit #1
Unit #2
Unit #3
Unit #4
Unit #5
Unit #6
Unit #7
Unit #8
Unit #9
Unit #10
Unit #11
Unit #12 Unit #13
Unit #14
Unit #15
Unit #16
Unit #17
Unit #18
Unit #19
Unit #20
Unit #21
Unit #22
Unit #23
Unit #24
Unit #25
Unit #26
Unit #27
Unit #28
Unit #29
Unit #30
Unit #31
Unit #32
Unit #33
Unit #34
1 of 6
1
Plate Height
W3 109' - 1 1/8"
6
8
13 13
3
6"
12"
2"
12"
R1 R2
Mail Boxes
4
Plate Height
109' - 1 1/8"
W3
R2 R1
6
8
13
14
4
13
12' - 0"
10' - 0"
1 of 6
3
1 of 6
2
Mail boxes
Electrical for
neighborhood lighting
Neighborhood
landscape irrigation
controls & backflow.
Issued
Drawing Number
Scale Accordingly if Reduced
Project No.: Drawn by:
Reviewed by:
In Association with:
ARCHITECTS
r4 architects.com
226 Remington
Unit #3
Fort Collins, CO 80524
phone 970/224-0630
www.r4architects.com
PDF Review
ARCH
1 PDP Submittal 08/09/2016
Contact: Blake Larsen
Email: blake@larsensd.com
Larsen Structural Design
Phone: (970) 568-3355
Fort Collins, CO 80524
19 Old Town Square, Suite 238
Structural Engineer
Contact: Tom Segelhorst
Email: Thomas-s@int-mech.com
Integrated Mechanical
Phone: (970)556-0570
Fort Collins, CO 80524
223 Linden St. Suite 204
Mech/Plumbing Engineer
Contact: Chuck Polson
Email: chuck@apsinc.biz
APS, Inc.
Phone: (970) 381-7462
Highlands Ranch, CO 80129
9249 S. Broadway, #200-836
Electrical Engineer
Contact: Mike Oberlander
Email: moberlander@Interwestgrp.com
Interwest Consulting Group
Phone: (970)674-3300
Windsor, CO 80550
1218 Ash Street
Civil Engineer
Contact: Cathy Mathis & Jim Doyle
Email: cathy@tbgroup.us, doyle@tbgroup.us
TB Group
Phone: (970)532-5891
Berthoud, CO 80531
444 Mountain Avenue
Planning & Landscape
Contact: Tyler Texeira
Email: Tyler@Beacon-Con.com
Columbine Health Systems
Phone: (970)566-1432
Fort Collins, CO 80527
PO Box 270218
Owner
Contact: Tyler Texeira
Email: Tyler@Beacon-Con.com
Beacon Construction
Phone: (970)566-1432
Fort Collins, CO 80527
PO Box 270218
General Contractor
2 PDF Review 09/19/2016
JDO, SA
MR
Architectural Site
Fort Collins, CO 80526
2016-11
Columbine
Residences
1 of 6
1" = 60'-0"
5
Planning Site Plan
Building Area Matrix
0 60 120 180 240
GRAPHIC SCALE
3D Street View Looking East
1/8" = 1'-0"
2
Amenities Building - South Elevation
1/8" = 1'-0"
3
Amenities Building - East Elevation
1/8" = 1'-0"
1
Mail Kiosk Plan
4
3D View of Amenities Building
Materials Legend
Modular Brick Veneer, field
Stone Veneer
Horizontal Siding
Shingle Siding
Direct Applied Thin Brick
Standard size brick - running bond
3/4" Thick color to match Modular Brick
Veneer - running bond
Thin stone veneer, field stone pattern
James Hardie Lap Siding
James Hardie: HardieShingle Siding,
Staggered Edge Panel
Pattern Material Name Material Description
W1
W2
W6
W3
W5
W4Siding Board & Batten Siding Board and Batten
R1 Roofing High profile asphalt shingles
1
Fixed or opperable window
unit
Basis of Design:
Anderson 100 Series, Colors: TBD
3
Main Entry Door
Basis of Design:
Masonite Barrington Craftsman Series,
Color: TBD
Keynote Legend
2
4
Roof Fascia
Fascia trim board painted,
Colors: TBD
5
Gutter & Downspout
Pre-finished metal, gutters and downspouts to
match fascia trim color.
6
Sectional Garage Door
Sectional garage door
Colors: TBD
7
8
Exposed Glulam Structure
Glulam structure stained,
Colors: TBD
Fireplace Cap
Gas fireplace round termination cap, Prefinished
Color: TBD
Keynote Keynote Item Description
Color TBD
Material Color / Finish
Basis of Design
Eldorado Stone: Country Rubble; Color: TBD
Exterior Light Fixture
Exterior wall sconce, Light fixture controlled by
individual tenant. Color: TBD
Basis of Design
Owens Corning: Duration Series - Color TBD
Color TBD
Basis of Design: HardiePlank Lap Siding, 4" exposure
Color TBD, Finish: smooth
Basis of Design: HardieShingle Siding,
Staggered Edge Panel
Color TBD, Finish: Cedar Mill
Basis of Design: HardiePanel Siding, w/ HardieTrim
Batten Boards @ 12' o.c.
Color TBD, Finish: smooth
R2 Roofing Standing seam metal roofing
Basis of Design
Berridge Manufacturing, CEE-LOCK, Color TBD
9 Gable end vent Vent will be square or pitched to match roof
10 Glulam lookout & knee
brace
Glulam structure stained,
Colors: TBD
Keynote Keynote Item Description
11 Patio doors
Basis of Design:
to match Anderson 100 Series, Colors: TBD
12 Fence/Railing Prefinished metal fence/railing, 30" high
13 Fence Post/Column Base
Masonry corner fence post to match adjacent column base w/
precast concrete cap, 36" high.
14 Electrical Gear Electrical meter and gear as specified by electrical drawings
No. Description Date
TREE TRUNK
WIRE, TYP.
NOTE: THE WIRE BETWEEN THE STAKE
AND THE TREE MUST HAVE SLACK
5' MIN.
GROMMETED NYLON STRAP, TYP.
NOTE:
WIRE BASKETS AND TWINE SHALL BE COMPLETELY
REMOVED PRIOR TO TREE INSTALLATION.
THAN FINISH GRADE / IRRIGATION TREE WELL TO BE PROVIDED
TOP OF ROOT CROWN TO BE 1" HIGHER
DRIVE THREE (3) WOOD STAKES PER
TREE FOR TREES OVER 6' IN HEIGHT.
DRIVE TWO (2) WOOD STAKES FOR
TREES 6' IN HEIGHT OR LESS. SPACE
ANCHORS EQUALLY AROUND TRUNK.
AVOID DAMAGE TO BRANCHES.
EXISTING SOIL
SLOW RELEASE FERTILIZER TABLET (TYP.)
BACKFILL W/ 2/3 NATIVE SOIL & 1/3
COMPOST. THOROUGHLY WATER
SETTLE
REMOVE WIRE CAGE AND/OR TWINE. OPEN BURLAP
AROUND TRUNK. CUT & REMOVE TOP 1/3 OF BURLAP
18" MIN.,
TYP.
SECTION
12" MIN.
ROOTBALL
THAN DIA. OF
24" GREATER
FINISH GRADE
PLAN
TREE TRUNK
T-POST
GROMMETED NYLON STRAP, TYP.
WIRE, TYP.
NOTE: THE WIRE BETWEEN THE STAKE
AND THE TREE MUST HAVE SLACK
TOP OF ROOT CROWN TO
BE 1" HIGHER THAN
FINISH GRADE
NOTE:
WIRE BASKETS AND TWINE SHALL BE COMPLETELY
REMOVED PRIOR TO TREE INSTALLATION.
DECIDUOUS TREE PLANTING DETAIL CONIFER TREE PLANTING DETAIL
NOTE:
CEDAR MULCH TREE
RING SHALL BE 36" DIA.
3" MULCH
ROOTBALL
DEPTH
ROOTBALL
DEPTH
ROOTBALL
DEPTH
TIE GROMMETED NYLON STRAPS TO STAKE WITH WIRE. WIRE
ENDS SHALL BE BENT BACK TO ELIMINATE BURRS AND WHITE PVC
PIPE ALONG ENTIRE LENGTH OF WIRE FOR VISUAL AND SAFETY
FOR ALL TREES WITHIN THE BUFFER ENHANCEMENT ZONE
FOR ALL TREES WITHIN THE BUFFER ENHANCEMENT ZONE
92,270 S.F.
ALL SHRUB BEDS TO RECEIVE A MINIMUM 4"-6" DEPTH
SHREDDED CEDAR WOOD MULCH
SHREDDED CEDAR MULCH
14,880 S.F.
NON-IRRIGATED PRAIRIE MEADOW GRASS MIX
STEEL EDGER, ROUNDED TOP
NATURAL HABITAT BUFFER
PLEASE SEE SECTION 3.4.1 OF
THE LAND USE CODE FOR
ALLOWABLE USES WITHIN THE
NATURAL HABITAT BUFFER
ZONE.
60,871 S.F.
DURA-TURF FESCUE BLEND SEED
IRRIGATED TURF
NOTES:
1. PLEASE SEE SECTION 3.4.1 OF THE
LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NATURAL HABITAT
BUFFER ZONE. THE NATURAL HABITAT
BUFFER ZONE IS INTENDED TO BE
MAINTAINED IN A NATIVE LANDSCAPE.
Sheet Number:
Fort Collins, CO
Worthington
Avenue
Residences
GROUP
landscape architecture|planning|illustration
444 Mountain Ave.
Behtroud,CO 80513
TEL
WEB
970.532.5891
TBGroup.us
PROJECT TITLE
REVISIONS
ISSUE DATE
SHEET TITLE
SHEET INFORMATION
DATE
SEAL
8-9-16
DATE
PREPARED FOR
Columbine Health
Systems
802 West Drake Road
Suite 101
Fort Collins CO 80525
Landscape Notes,
Details & Schedules
Hydrozone Table
ZONE AREA WATER USE GALLONS
HIGH 0 SF 18 GAL/SF 0 GAL
MODERATE 60,871 SF 10 GAL/SF 608,710 GAL
LOW 14,880 SF 3 GAL/SF 44,640 GAL
VERY LOW 92,270 SF 0 GAL/SF 0 GAL
TOTAL / AVERAGE 168,021 SF 653,350 GAL 3.9 GAL/SF
Plant List
3
NATIVE GRASS - NATIVE PRAIRIE MEADOW GRASS MIX:
1. SEED SHALL BE AS MANUFACTURED BY ARKANSAS VALLEY SEED SOLUTIONS, 4625 COLORADO
BOULEVARD, DENVER, CO 80216, (877) 957-3337.
2. SEED SHALL BE A MIXTURE THAT MATCHES THE FOLLOWING:
NON-IRRIGATED NATIVE PRAIRIE SEED MIX
COMMON NAME SEEDING RATE (PLS LBS/ACRE-DRILL RATE)
PURPLE THREE-AWN 2
BUFFALOGRASS 8
SQUIRRELTAIL 2
WESTERN WHEATGRASS 6
SANDBERG BLUEGRASS 1/2
BLUE GRAMA (COATED) 3
NEEDLE AND THREAD 4
FRINGED SAGE 1/16
PLAINS COREOPSIS 1/16
PLAINS WALLFLOWER 1/8
BLANKET FLOWER 1/2
DOTTED GAYFEATHER 1/2
NARROWLEAF PENSTEMON 1/2
PRAIRIE CONEFLOWER 1/8
GLORIOSA DAISY 1/16
SCARLET GLOBEMALLOW 1/16
3. NATIVE SEED AREAS: ADEQUATE TEMPORARY IRRIGATION WILL BE PROVIDED FOR THE
ESTABLISHMENT AND MAINTENANCE FOR THESE SEEDED AREAS, AND THAT NATIVE GRASSES
SHALL BE MAINTAINED IN A CONDITION OF ACCEPTABLE HEIGHT, FREE OF WEEDS, TRASH AND
DEBRIS, AND SHALL NOT REPRESENT A FIRE HAZARD NOR BECOME A NUISANCE SITE FOR WATER
OR WIND EROSION.
MULCH IN ALL NATIVE SEED AREAS:
1. IMMEDIATELY FOLLOWING THE RAKING OPERATION, ADD STRAW MULCH TO THE SEEDED AREAS.
2. APPLY STRAW MULCH AT A MINIMUM OF 1.5 TONS PER ACRE OF AIR DRY MATERIAL. SPREAD
STRAW MULCH UNIFORMLY OVER THE AREA WITH MECHANICAL MULCH SPREADER / CRIMPER. DO
NOT MULCH WHEN WIND VELOCITY EXCEEDS 10 MPH.
3. WHEREVER THE USE OF CRIMPING EQUIPMENT IS PRACTICAL, PLACE MULCH IN THE MANNER
NOTED ABOVE AND ANCHOR IT INTO THE SOIL. USE A DISC SUCH AS A MULCH TILLER, WITH A FLAT
SERRATED DISC AT LEAS ¼ INCH IN THICKNESS, HAVING DULL EDGES, AND SPACE NO MORE THAN
9 INCHES APART, WITH DISCS OF SUFFICIENT DIAMETER TO PREVENT THE FRAME OF THE
EQUIPMENT FROM DRAGGING THE MULCH. ANCHOR MULCH A MINIMUM DEPTH OF 2 INCHES AND
ACROSS THE SLOPE WHERE PRACTICAL WITH NO MORE THAN TWO PASSES OF THE ANCHORING
EQUIPMENT.
4. IMMEDIATELY UPON COMPLETION OF THE MULCHING AND BINDING OPERATION, THE SEEDED
AREAS SHALL BE IRRIGATED, KEEPING THE TOP 2 INCHES OF SOIL EVENLY MOIST UNTIL SEED HAS
UNIFORMLY GERMINATED AND GROWN TO A HEIGHT OF 2-INCHES.
5. WATERING APPLICATION SHALL BE DONE IN A MANNER WHICH WILL PROVIDE UNIFORM COVERAGE
BUT WHICH WILL NOT CAUSE EROSION, MOVEMENT, OR DAMAGE TO THE FINISHED SURFACE.
Native Grass Seed Mix
General Landscape Notes
1. PLANT QUALITY: ALL PLANT MATERIAL SHALL BE A-GRADE OR NO. 1 GRADE - FREE OF ANY DEFECTS, OF NORMAL HEALTH, HEIGHT, LEAF DENSITY AND SPREAD APPROPRIATE TO THE
SPECIES AS DEFINED BY THE AMERICAN ASSOCIATION OF NURSERYMEN (AAN) STANDARDS. ALL TREES SHALL BE BALL AND BURLAP OR EQUIVALENT.
2. IRRIGATION: ALL LANDSCAPE AREAS WITHIN THE SITE INCLUDING TURF, SHRUB BEDS AND TREE AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC IRRIGATION SYSTEM. THE IRRIGATION
PLAN MUST BE REVIEWED AND APPROVED BY THE CITY OF FORT COLLINS WATER UTILITIES DEPARTMENT PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL TURF AREAS SHALL BE
IRRIGATED WITH AN AUTOMATIC POP-UP IRRIGATION SYSTEM. ALL SHRUB BEDS AND TREES, INCLUDING IN NATIVE SEED AREAS, SHALL BE IRRIGATED WITH AN AUTOMATIC DRIP
(TRICKLE) IRRIGATION SYSTEM, OR WITH AN ACCEPTABLE ALTERNATIVE APPROVED BY THE CITY WITH THE IRRIGATION PLANS. THE IRRIGATION SYSTEM SHALL BE ADJUSTED TO MEET
THE WATER REQUIREMENTS OF THE INDIVIDUAL PLANT MATERIAL.
3. TOPSOIL: TO THE MAXIMUM EXTENT FEASIBLE, TOPSOIL THAT IS REMOVED DURING CONSTRUCTION ACTIVITY SHALL BE CONSERVED FOR LATER USE ON AREAS REQUIRING
REVEGETATION AND LANDSCAPING.
4. SOIL AMENDMENTS: SOIL AMENDMENTS SHALL BE PROVIDED AND DOCUMENTED IN ACCORDANCE WITH CITY CODE SECTION 12-132. THE SOIL IN ALL LANDSCAPE AREAS, INCLUDING
PARKWAYS AND MEDIANS, SHALL BE THOUGHLY LOOSENED TO A DEPTH OF NOT LESS THAN EIGHT(8) INCHES AND SOIL AMENDMENT SHALL BE THOROUGHLY INCORPORATED INTO THE
SOIL OF ALL LANDSCAPE AREAS TO A DEPTH OF AT LEAST SIX(6) INCHES BY TILLING, DISCING OR OTHER SUITABLE METHOD, AT A RATE OF AT LEAST THREE (3) CUBIC YARDS OF SOIL
AMENDMENT PER ONE THOUSAND (1,000) SQUARE FEET OF LANDSCAPE AREA. PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY, A WRITTEN CERTIFICATION MUST BE
SUBMITTED TO THE CITY THAT ALL PLANTED AREAS, OR AREAS TO BE PLANTED, HAVE BEEN THOROUGHLY LOOSENED AND THE SOIL AMENDED, CONSISTENT WITH THE REQUIREMENTS
SET FORTH IN SECTION 12-132.
5. INSTALLATION AND GUARANTEE: ALL LANDSCAPING SHALL BE INSTALLED ACCORDING TO SOUND HORTICULTURAL PRACTICES IN A MANNER DESIGNED TO ENCOURAGE QUICK
ESTABLISHMENT AND HEALTHY GROWTH. ALL LANDSCAPING FOR EACH PHASE MUST BE EITHER INSTALLED OR THE INSTALLATION MUST BE SECURED WITH AN IRREVOCABLE LETTER
OF CREDIT, PERFORMANCE BOND, OR ESCROW ACCOUNT FOR 125% OF THE VALUATION OF THE MATERIALS AND LABOR PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR
ANY BUILDING IN SUCH PHASE.
6. MAINTENANCE: TREES AND VEGETATION, IRRIGATION SYSTEMS, FENCES, WALLS AND OTHER LANDSCAPE ELEMENTS WITH THESE FINAL PLANS SHALL BE CONSIDERED AS ELEMENTS OF
THE PROJECT IN THE SAME MANNER AS PARKING, BUILDING MATERIALS AND OTHER SITE DETAILS. THE APPLICANT, LANDOWNER OR SUCCESSORS IN INTEREST SHALL BE JOINTLY AND
SEVERALLY RESPONSIBLE FOR THE REGULAR MAINTENANCE OF ALL LANDSCAPING ELEMENTS IN GOOD CONDITION. ALL LANDSCAPING SHALL BE MAINTAINED FREE FROM DISEASE,
PESTS, WEEDS AND LITTER, AND ALL LANDSCAPE STRUCTURES SUCH AS FENCES AND WALLS SHALL BE REPAIRED AND REPLACED PERIODICALLY TO MAINTAIN A STRUCTURALLY
SOUND CONDITION.
7. REPLACEMENT: ANY LANDSCAPE ELEMENT THAT DIES, OR IS OTHERWISE REMOVED, SHALL BE PROMPTLY REPLACED IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS.
8. THE FOLLOWING SEPARATIONS SHALL BE PROVIDED BETWEEN TREES/SHRUBS AND UTILITIES:
40 FEET BETWEEN CANOPY TREES AND STREET LIGHTS
15 FEET BETWEEN ORNAMENTAL TREES AND STREETLIGHTS
10 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER MAIN LINES
6 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER SERVICE LINES.
4 FEET BETWEEN SHRUBS AND PUBLIC WATER AND SANITARY AND STORM SEWER LINES
4 FEET BETWEEN TREES AND GAS LINES
9. ALL STREET TREES SHALL BE PLACED A MINIMUM EIGHT (8) FEET AWAY FROM THE EDGES OF DRIVEWAYS AND ALLEYS PER LUC 3.2.1(D)(2)(A).
10. PLACEMENT OF ALL LANDSCAPING SHALL BE IN ACCORDANCE WITH THE SIGHT DISTANCE CRITERIA AS SPECIFIED BY THE CITY OF FORT COLLINS. NO STRUCTURES OR LANDSCAPE
ELEMENTS GREATER THAN 24" SHALL BE ALLOWED WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENTS WITH THE EXCEPTION OF DECIDUOUS TREES PROVIDED THAT THE LOWEST
BRANCH IS AT LEAST 6' FROM GRADE. ANY FENCES WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENT MUST BE NOT MORE THAN 42" IN HEIGHT AND OF AN OPEN DESIGN.
11. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO
BE MAINTAINED BY A PROPERTY OWNERS ASSOCIATION. THE PROPERTY OWNERS ASSOCIATION IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND ON
ALL DRIVEWAYS, PRIVATE DRIVES AND PARKING AREAS WITHIN THE DEVELOPMENT.
12. THE DEVELOPER SHALL ENSURE THAT THE FINAL LANDSCAPE PLAN IS COORDINATED WITH ALL OTHER FINAL PLAN ELEMENTS SO THAT THE PROPOSED GRADING, STORM DRAINAGE,
AND OTHER DEVELOPMENT IMPROVEMENTS DO NOT CONFLICT WITH NOR PRECLUDE INSTALLATION AND MAINTENANCE OF LANDSCAPE ELEMENTS ON THIS PLAN.
13. MINOR CHANGES IN SPECIES AND PLANT LOCATIONS MAY BE MADE DURING CONSTRUCTION -- AS REQUIRED BY SITE CONDITIONS OR PLANT AVAILABILITY. OVERALL QUANTITY,
QUALITY, AND DESIGN CONCEPT MUST BE CONSISTENT WITH THE APPROVED PLANS. IN THE EVENT OF CONFLICT WITH THE QUANTITIES INCLUDED IN THE PLANT LIST, SPECIES AND
QUANTITIES ILLUSTRATED SHALL BE PROVIDED. ALL CHANGES OF PLANT SPECIES AND LOCATION MUST HAVE WRITTEN APPROVAL BY THE CITY PRIOR TO INSTALLATION.
14. ALL PLANTING BEDS SHALL BE MULCHED TO A MINIMUM DEPTH OF THREE INCHES.
15. IRRIGATED TURF SHALL BE TEXAS BLUEGRASS/KENTUCKY BLUEGRASS HYBRID REVEILLE OR APPROVED EQUAL.
16. EDGING BETWEEN GRASS AND SHRUB BEDS SHALL BE 18" X 4" STEEL SET LEVEL WITH TOP OF SOD OR APPROVED EQUAL.
17. LANDSCAPING AND IRRIGATION WITHIN THE BUFFER ZONE ENHANCEMENT AREA SHALL BE ESTABLISHED AND MAINTAINED FOR A PERIOD OF AT LEAST THREE YEARS UNTIL IT
REACHES AN AGREED UPON LEVEL OF SUCCESS, AT WHICH POINT THE CONTINUED MAINTENANCE WILL BE TURNED OVER TO STORMWATER. THE ESTABLISHMENT & MAINTENANCE
PERIOD MAY BE EXTENDED PAST 3 YEARS BY THE CITY TO ENSURE THE REQUIRED LEVEL OF ESTABLISHMENT HAS OCCURRED. PRIOR TO THE AREA BEING TURNED OVER FOR
MAINTENANCE TO STORMWATER THE DEVELOPMENT SHALL CONTACT CITY REPRESENTATIVES FROM STORMWATER, FORESTRY AND ENVIRONMENTAL PLANNING FOR A SITE
INSPECTION. THE LEVEL OF ESTABLISHMENT MUST BE APPROVED BY THE CITY PRIOR TO THE MAINTENANCE BEING TRANSFERRED TO STORMWATER. ALL SHADE AND EVERGREEN
TREES NEED TO BE IN PLACE AND ESTABLISHED.
18. IRRIGATION PLANS ARE SUBJECT TO REVIEW AND APPROVAL BY THE CITY PRIOR TO ISSUANCE OF ANY BUILDING PERMIT.
19. WITHIN THE BUFFER ZONE ENHANCEMENT AREA SHRUBS SHALL HAVE 3 DRIP EMITTERS AND TREES SHALL HAVE 5 DRIP EMITTERS. MULCH BASINS SHALL BE 5"-6" HIGH.
20. NATURAL HABITAT AREA IS MEANT TO BE MAINTAINED IN A NATIVE LANDSCAPE.
21. REFER TO SECTION 3.4.1 OF THE CITY OF FORT COLLINS LAND USE CODE FOR ALLOWABLE USES WITHIN THE BUFFER ZONE ENHANCEMENT ZONE.
Street Tree Notes
1. A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC
RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO
BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING
OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY.
2. CONTACT THE CITY FORESTER TO INSPECT ALL STREET TREE PLANTINGS AT THE COMPLETION OF EACH PHASE OF THE DEVELOPMENT. ALL MUST BE INSTALLED AS SHOWN ON
THE LANDSCAPE PLAN. APPROVAL OF STREET TREE PLANTING IS REQUIRED BEFORE FINAL APPROVAL OF EACH PHASE.
3. STREET LANDSCAPING, INCLUDING STREET TREES, SHALL BE SELECTED IN ACCORDANCE WITH ALL CITY CODES AND POLICIES. ALL TREE PRUNING AND REMOVAL WORKS SHALL BE
PERFORMED BY A CITY OF FORT COLLINS LICENSED ARBORS WHERE REQUIRED BY CODE.STREET TREES SHALL BE SUPPLIED AND PLANTED BY THE DEVELOPER USING A QUALIFIED
LANDSCAPE CONTRACTOR.
4. THE DEVELOPER SHALL REPLACE DEAD OR DYING STREET TREES AFTER PLANTING UNTIL FINAL MAINTENANCE INSPECTION AND ACCEPTANCE BY THE CITY OF FORT COLLINS
FORESTRY DIVISION. ALL STREET TREES IN THE PROJECT MUST BE ESTABLISHED, WITH AN APPROVED SPECIES AND OF ACCEPTABLE CONDITION PRIOR TO ACCEPTANCE.
5. SUBJECT TO APPROVAL BY THE CITY FORESTER -- STREET TREE LOCATIONS MAY BE ADJUSTED TO ACCOMMODATE DRIVEWAY LOCATIONS, UTILITY SEPARATIONS BETWEEN TREES,
STREET SIGNS AND STREET LIGHTS. STREET TREES TO BE CENTERED IN THE MIDDLE OF THE LOT TO THE EXTENT FEASIBLE. QUANTITIES SHOWN ON PLAN MUST BE INSTALLED
UNLESS A REDUCTION IS APPROVED BY THE CITY TO MEET SEPARATION STANDARDS.
Tree Protection Notes
1. ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE
PLANS FOR REMOVAL.
2. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS
EVALUATED AND APPROVED THE DISTURBANCE.
3. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS
THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE.
4. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF
FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE
SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE.
5. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE
MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY
PROTECTED TREE OR GROUP OF TREES.
6. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE.
7. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS
MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY
PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS
BEING CLEARED.
8. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING
UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE
TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW:
TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET)
0-2 1
3-4 2
5-9 5
10-14 10
15-19 12
OVER 19 15
9. ALL TREE REMOVAL SHOWN SHALL BE COMPLETED OUTSIDE OF THE SONGBIRD NESTING SEASON (FEB 1 - JULY 31) OR CONDUCT A SURVEY OF TREES ENSURING NO ACTIVE NESTS
IN THE AREA.
A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC
RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND
SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO
RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY.
Landscape Legend
Plant List
Legend
AMENITY SPACE
POTENTIAL TRAIL
PARK
BENCH SEATING
AREA
5' WALK
NATURAL HABITAT
BUFFER ZONE
MAIL KIOSK SPACE
ENTRY PERENNIAL
FLOWER BED