Loading...
HomeMy WebLinkAboutCOLUMBINE RESIDENCES (FORMERLY WORTHINGTON AVENUE RESIDENCES) - FDP - FDP160045 - SUBMITTAL DOCUMENTS - ROUND 1 - ELEVATIONS5047.09 5046.75 5041.49 GRASS GRASS GRASS GRASS GRAVEL GRAVEL ASPHALT "PET WASTE" 300 5047.56 CP-SPRING SET #4 REBAR WITH 2" ALUMINUM CAP N=1446455.28 E=3114287.67 VERTICAL CURB & GUTTER RIVER ROCK CONC WALL RIVER ROCK 13 AC UNITS TRASH ENCLOSURE VERTICAL CURB CONCRETE PAN CONCRETE WALL CONCRETE DRAINAGE STRUCTURE CONCRETE WALL WORTHINGTON CIRCLE NEW MERCER DITCH LARIMER CANAL SMH W RIM=5047.3 INV (NW)=5036.9 INV (SE)=5036.8 15" RCP FL=5040.9 21"X36" RCP FL=5044.5 18" PIPE FL=5041.2 15" RCP FL=5042.2 15" CPP FL=5045.1 INLET AREA INLET CONCRETE DRAINAGE STRUCTURE 12" PVC FL=5042.3 S W O ET E T T SHOWER PAN SHOWER PAN R2 R1 W3 W1 W3 W5 W1 W5 W3 W2 W1 10 4 Roof Peak 121' - 10" W3 11 6 1 1 1 1 W1 1 11 1 W3 W1 4 3 4 R1 W3 7 10 3 9 10 4 3 4 6" 10 12" 6" 12" 6" 12" R1 R2 W5 W5 W5 W5 W3 W1 W1 W3 W1 W3 W1 10 10 3 10 3 10 3 10 10 10 3 Roof Peak 121' - 10" 1 8 2 8 10 5 10 8 1 2 8 10 5 6 4 6" 12" 3 R1 6" SHOWER PAN SHOWER PAN T.O. Sub Floor 100' - 0" Plate Height 109' - 1 1/8" R1 R1 R2 R1 R1 R1 R2 W3 W6 W4 W3 W6 W6 W4 W4 W6 W3 W6 W6 W3 W3 W6 W4 11 2 1 23 1 2 1 6 4 7 1 7 8 6 8 8 8 8 3 1/2" 12" 3 1/2" 12" T.O. Ridge 119' - 9 5/8" 13 12 13 13 13 T.O. Sub Floor 100' - 0" Plate Height 109' - 1 1/8" W6 R2 R1 R1 R1 W6 W4 W3 W3 W6 W6 W3 W6 W6 W3 W6 R1 W6 4 1 7 7 10 10 4 1 6 6 4 1 6 6 3 1/2" 12" 3 1/2" 12" T.O. Ridge 119' - 9 5/8" SHOWER PAN SHOWER PAN SHOWER PAN Roof Peak 119' - 5" W1 W3 R1 W5 W1 W3 W1 4 1 W3 1 W1 4 1 6 6 W3 1 W1 6 1 6 11 1 6 4 1 4 10 3 W1 W3 W5 R1 10 R2 4 W5 9 10 W2 R1 7 5" 12" 5" 12" 5" 12" 5" 12" 5" 12" Roof Peak 119' - 5" W1 W3 R2 W5 R1 1 W1 2 6 1 4 6 1 6 2 8 5 8 5 8 4 6 W3 6 W1 4 3 R1 R1 W2 R2 W5 W5 R1 7 10 9 10 3 4 4 1 10 5" 12" 5" 12" 5" 12" 5" 12" SHOWER PAN SHOWER PAN R1 R2 R1 W6 R1 R2 W6 W5 W3 W6 W6 W3 W6 W5 W6 W5 R1 W3 7 3 3 4 6 6 1 4 6 W6 1 W3 W6 4 1 10 7 3 10 10 10 3 3 4 4 1 10 66 1 4 4 4 T.O. Ridge 3 1/2" 121'-3 1/2" 12" 3 1/2" 12" 6" 12" 6" 12" 6" 12" 6" 12" 1 3/4" 12" R1 R1 R2 W5 R2 R1 W5 W3 W6 W6 W6 W3 10 1 W3 3 10 3 4 10 8 4 1 6 2 8 1 W3 8 10 5 3 10 W3 W6 2 10 8 5 5 10 8 W3 4 1 8 3 3 T.O. Ridge 121'-3 1/2" 6" SHOWER PAN SHOWER PAN T.O. Ridge 119'-4" R2 W3 W6 R2 W3 W6 W4 W6 W3 W4 W6 R2 W6 R1 9 3 7 4 1 1 11 1 1 1 1 11 1 1 4 4 3 9 7 6 10 6 6 4 6 6 6 4 33 4 5" 12" 5" 12" 5" 12" 5" 12" 5" 12" T.O. Ridge 119'-4" W4 W4 W4 W4 W3 W6 W6 W4 W6 W3 W3 W6 W3 R1 R2 7 W6 R2 7 W6 R2 9 4 3 9 10 3 4 4 5 2 1 5 4 6 2 1 4 4 3 33 6 3 3 6 6 8 8 8 8 8 8 5" 5" 12" 12" 5" 12" 5" 12" 5" 12" 5" 12" 5" 12" 13 12 13 13 12 13 W4 W6 R1 R1 W6 W4 W6 1 W6 1 W3 7 3 3 4 66 4 4 4 1 66 3 4 T.O. Ridge 119'-4" 5" 12" 3 1/2" 5" 12" 12" 13 Building elevation is located parallel to adjacent building and is not visible from surrounding areas. T.O. Ridge 119' - 4" 3 R2 7 10 W6 R1 3 44 W3 W6 W4 4 6 4 3 5" 12" 13 Building elevation is located parallel to adjacent building and is not visible from surrounding areas. 6 of 6 3 6 of 6 6 6 of 6 5 6 of 6 4 Adjacent Home on the same lot, refer to sheet ARCH 1 of 6 Adjacent Home on the same lot, refer to sheet ARCH 1 of 6 86' - 4" = 10.4% of Frontage 9' - 0" = 10.4% of Frontage 9' - 0" 14'Patio - 8" Patio 14' - 7 1/2" 13 12 13 4' - 1" 4' - 1" 13 12 13 Compliance per MuniCode 3.5.2(F) • Streets lined with active living spaces at each entry with oversized patio that extends 4'-0" minimum from the face of the garage. • Pedestrian-oriented streetscapes throughout the development • Enhances visual interest in the exterior building design includes masonry and metal railings along the front of each patio with enhanced landscaping. • Total garage door frontage = 18'-0" (20.8%) Extents of roof overhang, Typical. Extents of roof overhang, Typical. Issued Drawing Number Scale Accordingly if Reduced Project No.: Drawn by: Reviewed by: In Association with: ARCHITECTS r4 architects.com 226 Remington Unit #3 Fort Collins, CO 80524 phone 970/224-0630 www.r4architects.com Final Plan ARCH 1 Final Plan 11/01/2016 Contact: Blake Larsen Email: blake@larsensd.com Larsen Structural Design Phone: (970) 568-3355 Fort Collins, CO 80524 19 Old Town Square, Suite 238 Structural Engineer Contact: Tom Segelhorst Email: Thomas-s@int-mech.com Integrated Mechanical Phone: (970)556-0570 Fort Collins, CO 80524 223 Linden St. Suite 204 Mech/Plumbing Engineer Contact: Chuck Polson Email: chuck@apsinc.biz APS, Inc. Phone: (970) 381-7462 Highlands Ranch, CO 80129 9249 S. Broadway, #200-836 Electrical Engineer Contact: Mike Oberlander Email: moberlander@Interwestgrp.com Interwest Consulting Group Phone: (970)674-3300 Windsor, CO 80550 1218 Ash Street Civil Engineer Contact: Cathy Mathis & Jim Doyle Email: cathy@tbgroup.us, doyle@tbgroup.us TB Group Phone: (970)532-5891 Berthoud, CO 80531 444 Mountain Avenue Planning & Landscape Contact: Tyler Texeira Email: Tyler@Beacon-Con.com Columbine Health Systems Phone: (970)566-1432 Fort Collins, CO 80527 PO Box 270218 Owner Contact: Tyler Texeira Email: Tyler@Beacon-Con.com Beacon Construction Phone: (970)566-1432 Fort Collins, CO 80527 PO Box 270218 General Contractor Contact: Christy Texeira Email: ctintertwine@msn.com Intertwine Design Phone: (970) 377-9980 Fort Collins, CO - Interior Design SA, JDO MR Building Elevations Building Type; DD Fort Collins, CO 80526 2014-15 Columbine Residences 6 of 6 1/8" = 1'-0" 5 Backyard Elevation 1/8" = 1'-0" 3 Street Front Elevation Materials Legend Modular Brick Veneer, field Stone Veneer Horizontal Siding Shingle Siding Direct Applied Thin Brick Standard size brick - running bond 3/4" Thick color to match Modular Brick Veneer - running bond Thin stone veneer, field stone pattern James Hardie Lap Siding James Hardie: HardieShingle Siding, Staggered Edge Panel Pattern Material Name Material Description W1 W2 W6 W3 W5 W4Siding Board & Batten Siding Board and Batten R1 Roofing High profile asphalt shingles 1 Fixed or opperable window unit Basis of Design: Anderson 100 Series, Colors: TBD 3 Main Entry Door Basis of Design: Masonite Barrington Craftsman Series, Color: TBD Keynote Legend 2 4 Roof Fascia Fascia trim board painted, Colors: TBD 5 Gutter & Downspout Pre-finished metal, gutters and downspouts to match fascia trim color. 6 Sectional Garage Door Sectional garage door Colors: TBD 7 8 Exposed Glulam Structure Glulam structure stained, Colors: TBD Fireplace Cap Metal chimney cap with fireplace flue extending to the required clear height, Prefinished Color: TBD Keynote Keynote Item Description Color TBD Material Color / Finish Basis of Design Eldorado Stone: Country Rubble; Color: TBD Exterior Light Fixture Exterior wall sconce, Light fixture controlled by individual tenant. Color: TBD Basis of Design Owens Corning: Duration Series - Color TBD Color TBD Basis of Design: HardiePlank Lap Siding, 4" exposure Color TBD, Finish: smooth Basis of Design: HardieShingle Siding, Staggered Edge Panel Color TBD, Finish: Cedar Mill Basis of Design: HardiePanel Siding, w/ HardieTrim Batten Boards @ 12' o.c. Color TBD, Finish: smooth R2 Roofing Standing seam metal roofing Basis of Design Berridge Manufacturing, CEE-LOCK, Color TBD 9 Gable end vent Vent will be square or pitched to match roof 10 Glulam lookout Glulam structure stained, Colors: TBD Keynote Keynote Item Description 11 Patio doors Basis of Design: to match Anderson 100 Series, Colors: TBD 12 Fence/Railing Prefinished metal fence/railing, 30" high 13 Fence Post/Column Base Masonry corner fence post to match adjacent column base w/ precast concrete cap, 36" high. 14 Electrical Gear Electrical meter and gear as specified by electrical drawings 1/8" = 1'-0" 4 Left Side Elevation 1/8" = 1'-0" 6 Right Side Elevation 2 Building DD - 3D Street View 1/16" = 1'-0" 1 Building DD Planning Floor Plan No. Description Date 1 12" 6" 12" 3 1/2" 12" 3 1/2" 12" 6" 12" 6" 12" 13 12 13 6 13 13 W6 R1 R2 W5 R1 W5 R1 W3 W3 W6 W3 W6 7 3 4 6 1 66 11 44 1 3 8 4 4 2 1/2" 12" 5" 12" 5" 12" 5" 12" 2 1/2" 4 1/4" 12" 12" 2 1/2" 12" T.O. Ridge 121'-3 1/2" 6 13 Building elevation is located parallel to adjacent building and is not visible from surrounding areas. R1 R1 W5 R1 W6 W3 W3 W6 33 9 9 6 11 6 4 4 1 1 8 44 10 4 3 T.O. Ridge 121'-3 1/2" 5" 12" 4 1/4" 12" 4 1/4" 12" 2 1/2" 12" 5" 12" 13 Building elevation is located parallel to adjacent building and is not visible from surrounding areas. 5 of 6 3 5 of 6 6 5 of 6 5 of 6 5 4 Adjacent Home on the same lot, refer to sheet ARCH 1 of 6 Adjacent Home on the same lot, refer to sheet ARCH 1 of 6 91' - 0 1/2" 20' - 6" Patio 26' - 11 1/2" Patio = 21.4% of Frontage 19' - 6" = 17.6% of Frontage 16' - 0" 6' - 0" 13 12 13 5' - 8 1/2" 13 13 6 Area covered by a wood Pergola Extents of roof overhang, Typical. Extents of roof overhang, Typical. Compliance per MuniCode 3.5.2(F) • Streets lined with active living spaces at each entry with oversized patio that extends 4'-0" minimum from the face of the garage. • Pedestrian-oriented streetscapes throughout the development • Enhances visual interest in the exterior building design includes masonry and metal railings along the front of each patio with enhanced landscaping. A wood pergola is provided over one entry to extend the patio cover accordingly. • Total garage door frontage = 35'-6" (39.0%) Issued Drawing Number Scale Accordingly if Reduced Project No.: Drawn by: Reviewed by: In Association with: ARCHITECTS r4 architects.com 226 Remington Unit #3 Fort Collins, CO 80524 phone 970/224-0630 www.r4architects.com Final Plan ARCH 1 Final Plan 11/01/2016 Contact: Blake Larsen Email: blake@larsensd.com Larsen Structural Design Phone: (970) 568-3355 Fort Collins, CO 80524 19 Old Town Square, Suite 238 Structural Engineer Contact: Tom Segelhorst Email: Thomas-s@int-mech.com Integrated Mechanical Phone: (970)556-0570 Fort Collins, CO 80524 223 Linden St. Suite 204 Mech/Plumbing Engineer Contact: Chuck Polson Email: chuck@apsinc.biz APS, Inc. Phone: (970) 381-7462 Highlands Ranch, CO 80129 9249 S. Broadway, #200-836 Electrical Engineer Contact: Mike Oberlander Email: moberlander@Interwestgrp.com Interwest Consulting Group Phone: (970)674-3300 Windsor, CO 80550 1218 Ash Street Civil Engineer Contact: Cathy Mathis & Jim Doyle Email: cathy@tbgroup.us, doyle@tbgroup.us TB Group Phone: (970)532-5891 Berthoud, CO 80531 444 Mountain Avenue Planning & Landscape Contact: Tyler Texeira Email: Tyler@Beacon-Con.com Columbine Health Systems Phone: (970)566-1432 Fort Collins, CO 80527 PO Box 270218 Owner Contact: Tyler Texeira Email: Tyler@Beacon-Con.com Beacon Construction Phone: (970)566-1432 Fort Collins, CO 80527 PO Box 270218 General Contractor Contact: Christy Texeira Email: ctintertwine@msn.com Intertwine Design Phone: (970) 377-9980 Fort Collins, CO - Interior Design SA MR Building Elevations Building Type; CE Fort Collins, CO 80526 2016-11 Columbine Residences 5 of 6 1/8" = 1'-0" 5 Backyard Elevation 1/8" = 1'-0" 3 Street Front Elevation Materials Legend Modular Brick Veneer, field Stone Veneer Horizontal Siding Shingle Siding Direct Applied Thin Brick Standard size brick - running bond 3/4" Thick color to match Modular Brick Veneer - running bond Thin stone veneer, field stone pattern James Hardie Lap Siding James Hardie: HardieShingle Siding, Staggered Edge Panel Pattern Material Name Material Description W1 W2 W6 W3 W5 W4Siding Board & Batten Siding Board and Batten R1 Roofing High profile asphalt shingles 1 Fixed or opperable window unit Basis of Design: Anderson 100 Series, Colors: TBD 3 Main Entry Door Basis of Design: Masonite Barrington Craftsman Series, Color: TBD Keynote Legend 2 4 Roof Fascia Fascia trim board painted, Colors: TBD 5 Gutter & Downspout Pre-finished metal, gutters and downspouts to match fascia trim color. 6 Sectional Garage Door Sectional garage door Colors: TBD 7 8 Exposed Glulam Structure Glulam structure stained, Colors: TBD Fireplace Cap Metal chimney cap with fireplace flue extending to the required clear height, Prefinished Color: TBD Keynote Keynote Item Description Color TBD Material Color / Finish Basis of Design Eldorado Stone: Country Rubble; Color: TBD Exterior Light Fixture Exterior wall sconce, Light fixture controlled by individual tenant. Color: TBD Basis of Design Owens Corning: Duration Series - Color TBD Color TBD Basis of Design: HardiePlank Lap Siding, 4" exposure Color TBD, Finish: smooth Basis of Design: HardieShingle Siding, Staggered Edge Panel Color TBD, Finish: Cedar Mill Basis of Design: HardiePanel Siding, w/ HardieTrim Batten Boards @ 12' o.c. Color TBD, Finish: smooth R2 Roofing Standing seam metal roofing Basis of Design Berridge Manufacturing, CEE-LOCK, Color TBD 9 Gable end vent Vent will be square or pitched to match roof 10 Glulam lookout Glulam structure stained, Colors: TBD Keynote Keynote Item Description 11 Patio doors Basis of Design: to match Anderson 100 Series, Colors: TBD 12 Fence/Railing Prefinished metal fence/railing, 30" high 13 Fence Post/Column Base Masonry corner fence post to match adjacent column base w/ precast concrete cap, 36" high. 14 Electrical Gear Electrical meter and gear as specified by electrical drawings 1/8" = 1'-0" 4 Left Side Elevation 1/8" = 1'-0" 6 Right Side Elevation 2 Building CE - 3D Street View 1/16" = 1'-0" 1 Building CE Planning Floor Plan No. Description Date 5" 12" 1 3/4" 12" 13 W1 13 12 13 13 12 W3 W1 W5 R1 W3 W1 W2 R1 W5 W1 1 4 1 4 3 7 1 10 10 9 W5 3 R2 5" 12" 1 3/4" 5" 12" 5" 12" 12" 8 4 3 6 8 6 4 Roof Peak 119' - 5" 13 Building elevation is located parallel to adjacent building and is not visible from surrounding areas. Roof Peak 119' - 5" 4 6 4 4 6 W1 8 W3 W1 1 1 W3 1 W1 4 8 W1 R1 W5 R1 W5 R1 R1 R1 W2 R1 10 9 10 10 7 2 1/2" 12" 5" 12" 5" 12" 13 Building elevation is located parallel to adjacent building and is not visible from surrounding areas. *Provide transom window in unit #26 only. 4 of 6 3 4 of 6 6 4 of 6 4 of 6 5 4 Adjacent Home on the same lot, refer to sheet ARCH 1 of 6 Adjacent Home on the same lot, refer to sheet ARCH 1 of 6 88' - 9" = 10.1% of Frontage 9' - 0" 27' - 0" Patio 18' - 5 1/2" Patio 12 13 13 4' - 1" 4' - 1" Compliance per MuniCode 3.5.2(F) • Streets lined with active living spaces at each entry with oversized patio that extends 4'-0" minimum from the face of the garage. • Pedestrian-oriented streetscapes throughout the development • Enhances visual interest in the exterior building design includes masonry and metal railings along the front of each patio with enhanced landscaping. • Total garage door frontage = 25'-0" (28.1%) Extents of roof overhang, Typical. Extents of roof overhang, Typical. 13 = 18.0% of Frontage 13 12 16' - 0" Issued Drawing Number Scale Accordingly if Reduced Project No.: Drawn by: Reviewed by: In Association with: ARCHITECTS r4 architects.com 226 Remington Unit #3 Fort Collins, CO 80524 phone 970/224-0630 www.r4architects.com Final Plan ARCH 1 Final Plan 11/01/2016 Contact: Blake Larsen Email: blake@larsensd.com Larsen Structural Design Phone: (970) 568-3355 Fort Collins, CO 80524 19 Old Town Square, Suite 238 Structural Engineer Contact: Tom Segelhorst Email: Thomas-s@int-mech.com Integrated Mechanical Phone: (970)556-0570 Fort Collins, CO 80524 223 Linden St. Suite 204 Mech/Plumbing Engineer Contact: Chuck Polson Email: chuck@apsinc.biz APS, Inc. Phone: (970) 381-7462 Highlands Ranch, CO 80129 9249 S. Broadway, #200-836 Electrical Engineer Contact: Mike Oberlander Email: moberlander@Interwestgrp.com Interwest Consulting Group Phone: (970)674-3300 Windsor, CO 80550 1218 Ash Street Civil Engineer Contact: Cathy Mathis & Jim Doyle Email: cathy@tbgroup.us, doyle@tbgroup.us TB Group Phone: (970)532-5891 Berthoud, CO 80531 444 Mountain Avenue Planning & Landscape Contact: Tyler Texeira Email: Tyler@Beacon-Con.com Columbine Health Systems Phone: (970)566-1432 Fort Collins, CO 80527 PO Box 270218 Owner Contact: Tyler Texeira Email: Tyler@Beacon-Con.com Beacon Construction Phone: (970)566-1432 Fort Collins, CO 80527 PO Box 270218 General Contractor Contact: Christy Texeira Email: ctintertwine@msn.com Intertwine Design Phone: (970) 377-9980 Fort Collins, CO - Interior Design JDO, SA MR Building Elevations Building Type: BE Fort Collins, CO 80526 2016-11 Columbine Residences 4 of 6 1/8" = 1'-0" 5 Backyard Elevation 1/8" = 1'-0" 3 Street Front Elevation Materials Legend Modular Brick Veneer, field Stone Veneer Horizontal Siding Shingle Siding Direct Applied Thin Brick Standard size brick - running bond 3/4" Thick color to match Modular Brick Veneer - running bond Thin stone veneer, field stone pattern James Hardie Lap Siding James Hardie: HardieShingle Siding, Staggered Edge Panel Pattern Material Name Material Description W1 W2 W6 W3 W5 W4Siding Board & Batten Siding Board and Batten R1 Roofing High profile asphalt shingles 1 Fixed or opperable window unit Basis of Design: Anderson 100 Series, Colors: TBD 3 Main Entry Door Basis of Design: Masonite Barrington Craftsman Series, Color: TBD Keynote Legend 2 4 Roof Fascia Fascia trim board painted, Colors: TBD 5 Gutter & Downspout Pre-finished metal, gutters and downspouts to match fascia trim color. 6 Sectional Garage Door Sectional garage door Colors: TBD 7 8 Exposed Glulam Structure Glulam structure stained, Colors: TBD Fireplace Cap Metal chimney cap with fireplace flue extending to the required clear height, Prefinished Color: TBD Keynote Keynote Item Description Color TBD Material Color / Finish Basis of Design Eldorado Stone: Country Rubble; Color: TBD Exterior Light Fixture Exterior wall sconce, Light fixture controlled by individual tenant. Color: TBD Basis of Design Owens Corning: Duration Series - Color TBD Color TBD Basis of Design: HardiePlank Lap Siding, 4" exposure Color TBD, Finish: smooth Basis of Design: HardieShingle Siding, Staggered Edge Panel Color TBD, Finish: Cedar Mill Basis of Design: HardiePanel Siding, w/ HardieTrim Batten Boards @ 12' o.c. Color TBD, Finish: smooth R2 Roofing Standing seam metal roofing Basis of Design Berridge Manufacturing, CEE-LOCK, Color TBD 9 Gable end vent Vent will be square or pitched to match roof 10 Glulam lookout Glulam structure stained, Colors: TBD Keynote Keynote Item Description 11 Patio doors Basis of Design: to match Anderson 100 Series, Colors: TBD 12 Fence/Railing Prefinished metal fence/railing, 30" high 13 Fence Post/Column Base Masonry corner fence post to match adjacent column base w/ precast concrete cap, 36" high. 14 Electrical Gear Electrical meter and gear as specified by electrical drawings 1/8" = 1'-0" 4 Left Side Elevation 1/8" = 1'-0" 6 Right Side Elevation 1/16" = 1'-0" 1 Building BE Planning Floor Plan 2 Building BE - 3D Street View No. Description Date 3 of 6 5 3 of 6 3 3 of 6 4 Adjacent Home on the same lot, refer to sheet ARCH 1 of 6 83' - 0" Overall Street Frontage = 21.7% of Frontage 18' - 0" Adjacent Home on the same lot, refer to sheet ARCH 1 of 6 = 10.8% of Frontage 9' - 0" 17' - 6" Patio 14' - 9 1/2" Patio Area covered by a wood Pergola Extents of roof overhang, Typical. Extents of roof overhang, Typical. 3 of 6 6 Compliance per MuniCode 3.5.2(F) • Streets lined with active living spaces at each entry with oversized patio that extends 4'-0" minimum from the face of the garage. • Pedestrian-oriented streetscapes throughout the development • Enhances visual interest in the exterior building design includes masonry and metal railings along the front of each patio with enhanced landscaping. A wood pergola is provided over one entry to extend the patio cover accordingly. • Total garage door frontage = 27'-0" (32.5%) 13 12 13 13 13 6 4' - 1" 4' - 1" T.O. Sub Floor 100' - 0" Plate Height 109' - 1 1/8" W6 R1 W4 R1 W6 W3 R1 1 1 1 4 W3 W6 R1 7 10 7 10 3 1/2" 12" 8 W6 4 T.O. Ridge 119' - 9 5/8" 13 Building elevation is located parallel to adjacent building and is not visible from surrounding areas. T.O. Sub Floor 100' - 0" Plate Height 109' - 1 1/8" R1 R1 R1 W6 R2 W3 W6 R2 W4 W6 W3 W6 W4 W4 W3 4 1 6 1 1 1 8 3 1/2" 12" 10 7 10 7 4 6 11 W6 T.O. Ridge 119' - 9 5/8" 13 6 Building elevation is located parallel to adjacent building and is not visible from surrounding areas. Issued Drawing Number Scale Accordingly if Reduced Project No.: Drawn by: Reviewed by: In Association with: ARCHITECTS r4 architects.com 226 Remington Unit #3 Fort Collins, CO 80524 phone 970/224-0630 www.r4architects.com Final Plan ARCH 1 Final Plan 11/01/2016 Contact: Blake Larsen Email: blake@larsensd.com Larsen Structural Design Phone: (970) 568-3355 Fort Collins, CO 80524 19 Old Town Square, Suite 238 Structural Engineer Contact: Tom Segelhorst Email: Thomas-s@int-mech.com Integrated Mechanical Phone: (970)556-0570 Fort Collins, CO 80524 223 Linden St. Suite 204 Mech/Plumbing Engineer Contact: Chuck Polson Email: chuck@apsinc.biz APS, Inc. Phone: (970) 381-7462 Highlands Ranch, CO 80129 9249 S. Broadway, #200-836 Electrical Engineer Contact: Mike Oberlander Email: moberlander@Interwestgrp.com Interwest Consulting Group Phone: (970)674-3300 Windsor, CO 80550 1218 Ash Street Civil Engineer Contact: Cathy Mathis & Jim Doyle Email: cathy@tbgroup.us, doyle@tbgroup.us TB Group Phone: (970)532-5891 Berthoud, CO 80531 444 Mountain Avenue Planning & Landscape Contact: Tyler Texeira Email: Tyler@Beacon-Con.com Columbine Health Systems Phone: (970)566-1432 Fort Collins, CO 80527 PO Box 270218 Owner Contact: Tyler Texeira Email: Tyler@Beacon-Con.com Beacon Construction Phone: (970)566-1432 Fort Collins, CO 80527 PO Box 270218 General Contractor Contact: Christy Texeira Email: ctintertwine@msn.com Intertwine Design Phone: (970) 377-9980 Fort Collins, CO - Interior Design JDO, SA MR Building Elevations Building Type: AD Fort Collins, CO 80526 2016-11 Columbine Residences 3 of 6 1/8" = 1'-0" 3 Street Front Elevation 1/8" = 1'-0" 5 Backyard Elevation Materials Legend Modular Brick Veneer, field Stone Veneer Horizontal Siding Shingle Siding Direct Applied Thin Brick Standard size brick - running bond 3/4" Thick color to match Modular Brick Veneer - running bond Thin stone veneer, field stone pattern James Hardie Lap Siding James Hardie: HardieShingle Siding, Staggered Edge Panel Pattern Material Name Material Description W1 W2 W6 W3 W5 W4Siding Board & Batten Siding Board and Batten R1 Roofing High profile asphalt shingles 1 Fixed or opperable window unit Basis of Design: Anderson 100 Series, Colors: TBD 3 Main Entry Door Basis of Design: Masonite Barrington Craftsman Series, Color: TBD Keynote Legend 2 4 Roof Fascia Fascia trim board painted, Colors: TBD 5 Gutter & Downspout Pre-finished metal, gutters and downspouts to match fascia trim color. 6 Sectional Garage Door Sectional garage door Colors: TBD 7 8 Exposed Glulam Structure Glulam structure stained, Colors: TBD Fireplace Cap Metal chimney cap with fireplace flue extending to the required clear height, Prefinished Color: TBD Keynote Keynote Item Description Color TBD Material Color / Finish Basis of Design Eldorado Stone: Country Rubble; Color: TBD Exterior Light Fixture Exterior wall sconce, Light fixture controlled by individual tenant. Color: TBD Basis of Design Owens Corning: Duration Series - Color TBD Color TBD Basis of Design: HardiePlank Lap Siding, 4" exposure Color TBD, Finish: smooth Basis of Design: HardieShingle Siding, Staggered Edge Panel Color TBD, Finish: Cedar Mill Basis of Design: HardiePanel Siding, w/ HardieTrim Batten Boards @ 12' o.c. Color TBD, Finish: smooth R2 Roofing Standing seam metal roofing Basis of Design Berridge Manufacturing, CEE-LOCK, Color TBD 9 Gable end vent Vent will be square or pitched to match roof 10 Glulam lookout Glulam structure stained, Colors: TBD Keynote Keynote Item Description 11 Patio doors Basis of Design: to match Anderson 100 Series, Colors: TBD 12 Fence/Railing Prefinished metal fence/railing, 30" high 13 Fence Post/Column Base Masonry corner fence post to match adjacent column base w/ precast concrete cap, 36" high. 14 Electrical Gear Electrical meter and gear as specified by electrical drawings 1/16" = 1'-0" 1 Building AD Planning Floor Plan 1/8" = 1'-0" 4 Left Side Elevation 1/8" = 1'-0" 6 Right Side Elevation 2 Building AD - 3D Street View No. Description Date 12" 6" 12" 1 6" 12" 6" 12" 13 12 13 13 12 13 8 R1 W1 R1 10 Roof Peak 121' - 10" 8 6 8 4 11 W1 1 4 W1 W3 4 1 4 W5 4 3 5" 12" 5" 12" 10 9 R1 W5 4 R1 13 Building elevation is located parallel to adjacent building and is not visible from surrounding areas. R1 W3 R1 W1 W5 R1 W5 W2 Roof Peak 121' - 10" W1 W3 1 1 4 8 3 4 10 9 10 10 7 4 4 W3 3" 12" 5" 12" 5" 12" 3" 12" 13 Building elevation is located parallel to adjacent building and is not visible from surrounding areas. 2 of 6 3 2 of 6 6 2 of 6 2 of 6 5 4 Adjacent Home on the same lot, refer to sheet ARCH 1 of 6 Adjacent Home on the same lot, refer to sheet ARCH 1 of 6 Compliance per MuniCode 3.5.2(F) • Streets lined with active living spaces at each entry with oversized patio that extends 4'-0" minimum from the face of the garage. • Pedestrian-oriented streetscapes throughout the development • Enhances visual interest in the exterior building design includes masonry and metal railings along the front of each patio with enhanced landscaping. • Total garage door frontage = 36'-0" (44.6%) 80' - 10 1/2" = 22.3% of Frontage 18' - 0" = 22.3% of Frontage 18' - 0" 17'Patio - 9" Patio 16' - 10 1/2" 4' - 0 1/2" 4' - 1" 12' - 7" Extents of roof overhang, Typical. Extents of roof overhang, Typical. 12 13 13 13 12 13 Issued Drawing Number Scale Accordingly if Reduced Project No.: Drawn by: Reviewed by: In Association with: ARCHITECTS r4 architects.com 226 Remington Unit #3 Fort Collins, CO 80524 phone 970/224-0630 www.r4architects.com Final Plan ARCH 1 Final Plan 11/01/2016 Contact: Blake Larsen Email: blake@larsensd.com Larsen Structural Design Phone: (970) 568-3355 Fort Collins, CO 80524 19 Old Town Square, Suite 238 Structural Engineer Contact: Tom Segelhorst Email: Thomas-s@int-mech.com Integrated Mechanical Phone: (970)556-0570 Fort Collins, CO 80524 223 Linden St. Suite 204 Mech/Plumbing Engineer Contact: Chuck Polson Email: chuck@apsinc.biz APS, Inc. Phone: (970) 381-7462 Highlands Ranch, CO 80129 9249 S. Broadway, #200-836 Electrical Engineer Contact: Mike Oberlander Email: moberlander@Interwestgrp.com Interwest Consulting Group Phone: (970)674-3300 Windsor, CO 80550 1218 Ash Street Civil Engineer Contact: Cathy Mathis & Jim Doyle Email: cathy@tbgroup.us, doyle@tbgroup.us TB Group Phone: (970)532-5891 Berthoud, CO 80531 444 Mountain Avenue Planning & Landscape Contact: Tyler Texeira Email: Tyler@Beacon-Con.com Columbine Health Systems Phone: (970)566-1432 Fort Collins, CO 80527 PO Box 270218 Owner Contact: Tyler Texeira Email: Tyler@Beacon-Con.com Beacon Construction Phone: (970)566-1432 Fort Collins, CO 80527 PO Box 270218 General Contractor Contact: Christy Texeira Email: ctintertwine@msn.com Intertwine Design Phone: (970) 377-9980 Fort Collins, CO - Interior Design JDO, SA MR Building Elevations Building Type: AA Fort Collins, CO 80526 2014-15 Columbine Residences 2 of 6 1/8" = 1'-0" 5 Backyard Elevation 1/8" = 1'-0" 3 Street Front Elevation Materials Legend Modular Brick Veneer, field Stone Veneer Horizontal Siding Shingle Siding Direct Applied Thin Brick Standard size brick - running bond 3/4" Thick color to match Modular Brick Veneer - running bond Thin stone veneer, field stone pattern James Hardie Lap Siding James Hardie: HardieShingle Siding, Staggered Edge Panel Pattern Material Name Material Description W1 W2 W6 W3 W5 W4Siding Board & Batten Siding Board and Batten R1 Roofing High profile asphalt shingles 1 Fixed or opperable window unit Basis of Design: Anderson 100 Series, Colors: TBD 3 Main Entry Door Basis of Design: Masonite Barrington Craftsman Series, Color: TBD Keynote Legend 2 4 Roof Fascia Fascia trim board painted, Colors: TBD 5 Gutter & Downspout Pre-finished metal, gutters and downspouts to match fascia trim color. 6 Sectional Garage Door Sectional garage door Colors: TBD 7 8 Exposed Glulam Structure Glulam structure stained, Colors: TBD Fireplace Cap Metal chimney cap with fireplace flue extending to the required clear height, Prefinished Color: TBD Keynote Keynote Item Description Color TBD Material Color / Finish Basis of Design Eldorado Stone: Country Rubble; Color: TBD Exterior Light Fixture Exterior wall sconce, Light fixture controlled by individual tenant. Color: TBD Basis of Design Owens Corning: Duration Series - Color TBD Color TBD Basis of Design: HardiePlank Lap Siding, 4" exposure Color TBD, Finish: smooth Basis of Design: HardieShingle Siding, Staggered Edge Panel Color TBD, Finish: Cedar Mill Basis of Design: HardiePanel Siding, w/ HardieTrim Batten Boards @ 12' o.c. Color TBD, Finish: smooth R2 Roofing Standing seam metal roofing Basis of Design Berridge Manufacturing, CEE-LOCK, Color TBD 9 Gable end vent Vent will be square or pitched to match roof 10 Glulam lookout Glulam structure stained, Colors: TBD Keynote Keynote Item Description 11 Patio doors Basis of Design: to match Anderson 100 Series, Colors: TBD 12 Fence/Railing Prefinished metal fence/railing, 30" high 13 Fence Post/Column Base Masonry corner fence post to match adjacent column base w/ precast concrete cap, 36" high. 14 Electrical Gear Electrical meter and gear as specified by electrical drawings 1/8" = 1'-0" 4 Left Side Elevation 1/8" = 1'-0" 6 Right Side Elevation 1/16" = 1'-0" 1 Building AA Planning Floor Plan 2 Building AA - 3D Street View No. Description Date E T E E Unit #1 Unit #2 Unit #3 Unit #4 Unit #5 Unit #6 Unit #7 Unit #8 Unit #9 Unit #10 Unit #11 Unit #12 Unit #13 Unit #14 Unit #15 Unit #16 Unit #17 Unit #18 Unit #19 Unit #20 Unit #21 Unit #22 Unit #23 Unit #24 Unit #25 Unit #26 Unit #27 Unit #28 Unit #29 Unit #30 Unit #31 Unit #32 Unit #33 Unit #34 1 of 6 1 Plate Height W3 109' - 1 1/8" 8 13 13 3 6" 12" 2" 12" R1 R2 Mail Boxes 4 Plate Height 109' - 1 1/8" W3 R2 R1 8 13 14 4 13 12' - 0" 10' - 0" 1 of 6 3 1 of 6 2 Mail boxes Electrical for neighborhood lighting Neighborhood landscape irrigation controls & backflow. Issued Drawing Number Scale Accordingly if Reduced Project No.: Drawn by: Reviewed by: In Association with: ARCHITECTS r4 architects.com 226 Remington Unit #3 Fort Collins, CO 80524 phone 970/224-0630 www.r4architects.com Final Plan ARCH 1 Final Plan 11/01/2016 Contact: Blake Larsen Email: blake@larsensd.com Larsen Structural Design Phone: (970) 568-3355 Fort Collins, CO 80524 19 Old Town Square, Suite 238 Structural Engineer Contact: Tom Segelhorst Email: Thomas-s@int-mech.com Integrated Mechanical Phone: (970)556-0570 Fort Collins, CO 80524 223 Linden St. Suite 204 Mech/Plumbing Engineer Contact: Chuck Polson Email: chuck@apsinc.biz APS, Inc. Phone: (970) 381-7462 Highlands Ranch, CO 80129 9249 S. Broadway, #200-836 Electrical Engineer Contact: Mike Oberlander Email: moberlander@Interwestgrp.com Interwest Consulting Group Phone: (970)674-3300 Windsor, CO 80550 1218 Ash Street Civil Engineer Contact: Cathy Mathis & Jim Doyle Email: cathy@tbgroup.us, doyle@tbgroup.us TB Group Phone: (970)532-5891 Berthoud, CO 80531 444 Mountain Avenue Planning & Landscape Contact: Tyler Texeira Email: Tyler@Beacon-Con.com Columbine Health Systems Phone: (970)566-1432 Fort Collins, CO 80527 PO Box 270218 Owner Contact: Tyler Texeira Email: Tyler@Beacon-Con.com Beacon Construction Phone: (970)566-1432 Fort Collins, CO 80527 PO Box 270218 General Contractor Contact: Christy Texeira Email: ctintertwine@msn.com Intertwine Design Phone: (970) 377-9980 Fort Collins, CO - Interior Design JDO, SA MR Architectural Site Fort Collins, CO 80526 2016-11 Columbine Residences 1 of 6 1" = 60'-0" 5 Planning Site Plan Building Area Matrix 0 60 120 180 240 GRAPHIC SCALE 3D Street View Looking East 1/8" = 1'-0" 2 Amenities Building - South Elevation 1/8" = 1'-0" 3 Amenities Building - East Elevation 1/8" = 1'-0" 1 Mail Kiosk Plan 4 3D View of Amenities Building Materials Legend Modular Brick Veneer, field Stone Veneer Horizontal Siding Shingle Siding Direct Applied Thin Brick Standard size brick - running bond 3/4" Thick color to match Modular Brick Veneer - running bond Thin stone veneer, field stone pattern James Hardie Lap Siding James Hardie: HardieShingle Siding, Staggered Edge Panel Pattern Material Name Material Description W1 W2 W6 W3 W5 W4Siding Board & Batten Siding Board and Batten R1 Roofing High profile asphalt shingles 1 Fixed or opperable window unit Basis of Design: Anderson 100 Series, Colors: TBD 3 Main Entry Door Basis of Design: Masonite Barrington Craftsman Series, Color: TBD Keynote Legend 2 4 Roof Fascia Fascia trim board painted, Colors: TBD 5 Gutter & Downspout Pre-finished metal, gutters and downspouts to match fascia trim color. 6 Sectional Garage Door Sectional garage door Colors: TBD 7 8 Exposed Glulam Structure Glulam structure stained, Colors: TBD Fireplace Cap Metal chimney cap with fireplace flue extending to the required clear height, Prefinished Color: TBD Keynote Keynote Item Description Color TBD Material Color / Finish Basis of Design Eldorado Stone: Country Rubble; Color: TBD Exterior Light Fixture Exterior wall sconce, Light fixture controlled by individual tenant. Color: TBD Basis of Design Owens Corning: Duration Series - Color TBD Color TBD Basis of Design: HardiePlank Lap Siding, 4" exposure Color TBD, Finish: smooth Basis of Design: HardieShingle Siding, Staggered Edge Panel Color TBD, Finish: Cedar Mill Basis of Design: HardiePanel Siding, w/ HardieTrim Batten Boards @ 12' o.c. Color TBD, Finish: smooth R2 Roofing Standing seam metal roofing Basis of Design Berridge Manufacturing, CEE-LOCK, Color TBD 9 Gable end vent Vent will be square or pitched to match roof 10 Glulam lookout Glulam structure stained, Colors: TBD Keynote Keynote Item Description 11 Patio doors Basis of Design: to match Anderson 100 Series, Colors: TBD 12 Fence/Railing Prefinished metal fence/railing, 30" high 13 Fence Post/Column Base Masonry corner fence post to match adjacent column base w/ precast concrete cap, 36" high. 14 Electrical Gear Electrical meter and gear as specified by electrical drawings No. Description Date