HomeMy WebLinkAboutCOLUMBINE RESIDENCES (FORMERLY WORTHINGTON AVENUE RESIDENCES) - FDP - FDP160045 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSAASHTO, 6th EDITION LRFD WITH CURRENT INTERIMS. DESIGN METHOD: LOAD AND RESISTANCE FACTOR DESIGN. LIVE LOAD: HL-93 (DESIGN TRUCK OR TANDEM, AND DESIGN LANE LOAD), COLORADO PERMIT VEHICLE. HANDRAILS: 50 plf + 200 lb (CONCURRENT) SOIL PROPERTIES: SOIL UNIT WEIGHT: 133 pcf SOIL UNIT WEIGHT (SATURATED): 140 pcf COEFFICIENT OF AT-REST PRESSURE: 0.43 ALLOWABLE NET BEARING PRESSURE: 1,500 psf REINFORCED CONCRETE: CLASS D CONCRETE: f'c = 4,500 psi REINFORCING STEEL: f'y = 60,000 psi SINGLE-CELL CONCRETE (20'-0" x 5'-0") BOX CULVERT (PRECAST) OVER NEW MERCER DITCH. 1'-0" HEADWALL + 78'-0" BOX CULVERT (PRECAST) + 1'-0" HEADWALL = (80'-0") OUT TO OUT. ƒ 6.(: 1'-0" HEADWALL WITH REMOVABLE HANDRAIL PRECAST CONCRETE BOX CULVERT SHALL CONFORM TO THE ASTM C1433 SPECIFICATION, TABLE 2. PRECAST JOINTS SHALL BE SEALED WITH AN APPROVED SYSTEM USING ONE OR MORE OF THE FOLLOWING: JOINT SEALANTS, RUBBER GASKETS, GEOTEXTILE, EXTERIOR JOINT WRAP MATERIAL. THE FOLLOWING SURFACES SHALL RECEIVE A COLORED STRUCTURAL CONCRETE STAIN. COLOR SHALL BE FEDERAL COLOR NUMBER XXXXX. 1. RAIL CURB TO 1'-0" MINIMUM BELOW GRADE. 2. ENDS OF BOX CULVERT. 3. WINGWALLS TO TOP OF APRON (FRONT FACE) AND 1'-0" BELOW GRADE (BACK FACE). SECTION OR DETAIL IDENTIFICATION CROSS-REFERENCE SHEET NUMBER S1 GENERAL NOTES S2 GENERAL LAYOUT S3 PRECAST SEGMENT LAYOUT S4 WINGWALL AND APRON PLANS S5 WINGWALL AND APRON DETAILS S6 PARAPET AND HANDRAIL DETAILS EXCEPT AS SHOWN IN THE PLANS, STRUCTURE EXCAVATION AND BACKFILL SHALL BE IN ACCORDANCE WITH M-206-1 FOR CAST-IN-PLACE RETAINING WALLS. STRUCTURE EXCAVATION AND BACKFILL SHALL BE AS SHOWN ON THE PLANS, EXCEPT SHORING MAY BE REQUIRED FOR EXCAVATION ADJACENT TO THE EXISTING ROADWAY. TEMPORARY EXCAVATION SUPPORT SHALL BE PAID FOR BY ITEM 206 SHORING. EXPANSION JOINT MATERIAL SHALL MEET AASHTO SPECIFICATION M213. GRADE 60 REINFORCING STEEL IS REQUIRED. ALL REINFORCING STEEL SHALL BE NON-EPOXY COATED UNLESS OTHERWISE NOTED. E DENOTES COATED REINFORCING STEEL. THE FOLLOWING TABLE GIVES THE MINIMUM LAP SPLICE LENGTH FOR EPOXY COATED REINFORCING BARS PLACED IN ACCORDANCE WITH SUBSECTION 602.06. THESE SPLICE LENGTHS SHALL BE INCREASED BY 25% FOR BARS SPACED AT LESS THAN 6" ON CENTER OR LESS THAN 3" OF LATERAL COVER. BAR SIZE #4 #5 #6 #7 #8 #9 #10 #11 SPLICE LENGTH FOR CLASS B OR D CONCRETE 1'-3" 1'-7" 2'-5" 2'-10" 3'-8" 4'-8" 5'-11" 7'-3" WHEN THE CONTRACTOR ELECTS TO SUBSTITUTE EPOXY COATED REINFORCEMENT FOR BLACK REINFORCING BARS, THE MINIMUM LAP SPLICE SHALL BE AS DESCRIBED ABOVE. THE FOLLOWING TABLE GIVES THE MINIMUM LAP SPLICE LENGTH FOR BLACK REINFORCING BARS PLACED IN ACCORDANCE WITH SUBSECTION 602.06. THESE SPLICE LENGTHS SHALL BE INCREASED BY 25% FOR BARS SPACED AT LESS THAN 6" ON CENTER OR LESS THAN 3" OF LATERAL COVER. BAR SIZE #4 #5 #6 #7 #8 #9 #10 #11 SPLICE LENGTH FOR CLASS B OR D CONCRETE 1'-1" 1'-4" 1'-7" 1'-11" 2'-6" 3'-1" 3'-11" 4'-10" THE ABOVE SPLICE LENGTHS SHALL BE INCREASED BY 20% FOR 3 BAR BUNDLES AND 33% FOR 4 BAR BUNDLES. 10'-0" 22'-0" 1'-0" 10'-0" 1'-0" 1'-2" 5'-0" 1'-2" 1'-0" (TYP) 1'-0" (TYP) 1'-6" 6" ROADWAY SURFACE BOX CULVERT PLAN BOX CULVERT ELEVATION TYPICAL SECTION (SECTION TAKEN ALONG CENTERLINE OF BOX CULVERT) (* DIMENSIONS MEASURED ALONG CENTERLINE OF BOX CULVERT) 0' 4' 8' 16' 0' 2' 4' 8' 0' 4' 8' 16' Revisions No. Date Description By Revisions No. Date Description By PRELIMINARY NOT FOR CONSTRUCTION Civil and Structural Engineering San Engineering LLC PREPARED FOR PROJ. NO. DATE: SCALE (H): SCALE (V): CHECKED BY: DESIGNED BY: PROJECT NAME 1278-069-00 LOT 1, CENTRE FOR ADVANCED TECH. 24TH FILING - COLUMBINE RESIDENCES BOX CULVERT GENERAL LAYOUT 10-13-16 N/A N/A JJM JJM S2 r4 ARCHITECTS 226 REMINGTON STREET, UNIT 3 FORT COLLINS, CO 80524 PHONE: 970.224.0630 3'-0" WIDE JOINT MEMBRANE OVER EXTERIOR JOINTS AS SHOWN. MEMBRANE SHALL BE GRACE ICE & WATER SHIELD SELF-ADHERE ROOFING UNDERLAYMENT BURIED FACE OF PRECAST UNIT. JOINT GAP (PER PRECAST MFR.) PRECAST SEGMENT LAYOUT PLAN PRECAST SEGMENT LAYOUT ELEVATION 0' 4.0' 8.0' 16.0' PREPARED FOR PROJ. NO. DATE: SCALE (H): SCALE (V): CHECKED BY: DESIGNED BY: PROJECT NAME 1278-069-00 LOT 1, CENTRE FOR ADVANCED TECH. 24TH FILING - COLUMBINE RESIDENCES BOX CULVERT PRECAST SEGMENT LAYOUT 10-13-16 N/A N/A JJM JJM S3 r4 ARCHITECTS 226 REMINGTON STREET, UNIT 3 FORT COLLINS, CO 80524 PHONE: 970.224.0630 0' 4.0' 8.0' 16.0' Revisions No. Date Description By Revisions No. Date Description By PRELIMINARY NOT FOR CONSTRUCTION Civil and Structural Engineering San Engineering LLC 1. PRECAST SEGMENT LENGTHS AND LAYOUTS SHOWN ON THIS SHEET ARE ONLY ONE POSSIBLE CONFIGURATION. PRECAST FABRICATOR MAY PROPOSE ALTERNATE ARRANGEMENTS. 2. PRECAST SHOP DRAWINGS AND PIECE FABRICATION SHALL TAKE INTO ACCOUNT CONSTRUCTION TOLERANCES AND GAPS BETWEEN ADJACENT PIECES SO AS TO PROVIDE A FINISHED STRUCTURE WITH INDICATED OUT-TO-OUT MEASUREMENTS. TYPICAL JOINT MEMBRANE DETAIL 0' 4.0' 8.0' 16.0' INTLET WINGWALL AND APRON PLAN 0' 1.0' 2.0' 4.0' OUTLET WINGWALL AND APRON PLAN PREPARED FOR PROJ. NO. DATE: SCALE (H): SCALE (V): CHECKED BY: DESIGNED BY: PROJECT NAME 1278-069-00 LOT 1, CENTRE FOR ADVANCED TECH. 24TH FILING - COLUMBINE RESIDENCES BOX CULVERT WING WALL AND APRON PLANS 10-13-16 N/A N/A JJM JJM S4 r4 ARCHITECTS 226 REMINGTON STREET, UNIT 3 FORT COLLINS, CO 80524 PHONE: 970.224.0630 Revisions No. Date Description By Revisions No. Date Description By 0' 1.0' 2.0' 4.0' Revisions No. Date Description By Revisions No. Date Description By PRELIMINARY NOT FOR CONSTRUCTION Civil and Structural Engineering San Engineering LLC ONE CUBIC FOOT OF 3/4" WASHED ROCK IN FILTER FABRIC SECURELY TIED. CENTER ON WEEP HOLE. (INCLUDED IN THE COST OF THE WINGWALLS) 2" CLR RE. SUBGRADE REQUIREMENTS #4 @ 12" 1'-6" (MIN) VARIES EL. VARIES #5 @ 12" 8" 1'-3" (MIN) 1'-3" (MIN) 6" (MIN) 1'-6" 8" 5'-4" 7'-6" CONSTRUCTION JOINT 8" 3'-0" 1'-6" (MIN) 1'-0" 3/4" CHAMFER (TYP) 3'-0" (MIN) TYPICAL WINGWALL SECTION APRON TOE WALL SECTION TYPICAL WINGWALL SECTION WINGWALL CONNECTION TO CULVERT APRON TOE WALL SECTION APRON CONNECTION TO CULVERT 0' 0.5' 1' 2' 0' 0.5' 1' 2' 0' 0.5' 1' 2' 0' 0.5' 1' 2' PREPARED FOR PROJ. NO. DATE: SCALE (H): SCALE (V): CHECKED BY: DESIGNED BY: PROJECT NAME 1278-069-00 LOT 1, CENTRE FOR ADVANCED TECH. 24TH FILING - COLUMBINE RESIDENCES BOX CULVERT WING WALL SECTIONS AND DETAILS 10-13-16 N/A N/A SIDEWALK PRECAST CBC UNIT (TYP) CURB & GUTTER. RE. ROADWAY PLANS 6" 3'-0" 21 2"Ⱦ STD PIPE (TYP) 3'-6" #4 E X @ 12" #6 E CONT. (6 TOT.) VARIES (23'-1" TO 25'-3" WEST, 19'-7" TO 21'-9" EAST) 1'-0" 6" EXTEND PRECAST CBC UNIT T & B REINFORCING 2'-0". BEND UP AS REQUIRED AT OUTSIDE FACE OF HEADWALL 2"Ⱦ STD PIPE x 10" 10" CONFIGURATION AT OPPOSITE HEADWALL 2 1/8" SET SCREWS. PLACE DIAMETRICLLY ALONG HANDRAIL AXIS 6" ABOVE BOTTOM OF POST. 2 1/2"Ⱦ STD PIPE FOR RAILS AND POSTS 2"Ⱦ STD PIPE x 10" BASE PL 1/2 x 6 x 0'-6" W/ 4 -13/16"Ⱦ HOLES @ 4 1/2" GAUGE FOR 4 -3/4"Ⱦ POST INSTALLED EXPANSION BOLTS 6" 10" CAST-IN-PLACE HEADWALL 20'-0" 5'-3" 5'-3" CONT. TUBE RAILS (TYP) STEEL POST (TYP) WINGWALL FOOTING GUARDRAIL POSTS 5'-3" 5'-3" (3 EQUAL SPACES) GUARDRAIL POSTS (3 EQUAL SPACES) TYPICAL PARAPET WALL SECTION OVER BOX CULVERT 0' 0.5' 1' 2' HEADWALL AND HANDRAIL ELEVATION (EAST AND WEST) 0' 1.0' 2.0' 4.0' Revisions No. Date Description By Revisions No. Date Description By PRELIMINARY NOT FOR CONSTRUCTION Civil and Structural Engineering San Engineering LLC PREPARED FOR PROJ. NO. DATE: SCALE (H): SCALE (V): CHECKED BY: DESIGNED BY: PROJECT NAME 1278-069-00 LOT 1, CENTRE FOR ADVANCED TECH. 24TH FILING - COLUMBINE RESIDENCES BOX CULVERT PARAPET AND HANDRAIL DETAILS 10-13-16 N/A N/A JJM JJM S6 r4 ARCHITECTS 226 REMINGTON STREET, UNIT 3 FORT COLLINS, CO 80524 PHONE: 970.224.0630 JJM JJM S5 r4 ARCHITECTS 226 REMINGTON STREET, UNIT 3 FORT COLLINS, CO 80524 PHONE: 970.224.0630 Revisions No. Date Description By Revisions No. Date Description By Revisions No. Date Description By Revisions No. Date Description By PRELIMINARY NOT FOR CONSTRUCTION Civil and Structural Engineering San Engineering LLC THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE DURING CONSTRUCTION. STATIONS, ELEVATIONS, AND DIMENSIONS CONTAINED IN THESE PLANS ARE CALCULATED FROM A RECENT FIELD SURVEY. THE CONTRACTOR SHALL VERIFY ALL DEPENDENT DIMENSIONS IN THE FIELD BEFORE ORDERING OR FABRICATING ANY MATERIAL. ALL LONGITUDINAL AND TRANSVERSE DIMENSIONS ARE MEASURED HORIZONTALLY AND INCLUDE NO CORRECTION FOR GRADE. THE INFORMATION SHOWN ON THESE PLANS CONCERNING THE TYPE AND LOCATION OF UNDERGROUND UTILITIES IS NOT GUARANTEED TO BE ACCURATE OR ALL INCLUSIVE. THE CONTRACTOR IS RESPONSIBLE FOR MAKING HIS OWN DETERMINATION AS TO THE TYPE AND LOCATION OF UNDERGROUND UTILITIES AS MAY BE NECESSARY TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT THE UTILITY NOTIFICATION CENTER OF COLORADO AT 811 (1-800-922-1987) AT LEAST 3 DAYS (2 DAYS NOT INCLUDING THE DAY OF NOTIFICATION) PRIOR TO ANY EXCAVATION OR OTHER EARTHWORK. PREPARED FOR PROJ. NO. DATE: SCALE (H): SCALE (V): CHECKED BY: DESIGNED BY: PROJECT NAME 1278-069-00 LOT 1, CENTRE FOR ADVANCED TECH. 24TH FILING - COLUMBINE RESIDENCES BOX CULVERT GENERAL NOTES 10-13-16 N/A N/A JJM JJM S1 r4 ARCHITECTS 226 REMINGTON STREET, UNIT 3 FORT COLLINS, CO 80524 PHONE: 970.224.0630 Revisions No. Date Description By Revisions No. Date Description By Revisions No. Date Description By Revisions No. Date Description By PRELIMINARY NOT FOR CONSTRUCTION Civil and Structural Engineering San Engineering LLC