HomeMy WebLinkAboutVILLAGE COOPERATIVE FORT COLLINS - PDP - PDP160036 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSHORSETOOTH ROAD
STANDFORD DRIVE
S. COLLEGE DRIVE
LANDINGS DRIVE
JOHN F. KENNEDY PKWY.
STOVER ROAD
E. MONROE DR.
S. LEMAY AVE.
E. SWALLOW ROAD
No. Revisions:
By: Date:
REVIEWED BY:
N. HAWS
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
10/25/16
PROJECT:
1284-001
Sheet
Of 15
VILLAGE COOPERATIVE OF FORT COLLINS
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
10/25/16
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
CS1
COVER SHEET
S. Thomas
A. Boese
N.T.S.
1
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
No. Revisions:
By: Date:
REVIEWED BY:
N. HAWS
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
10/25/16
PROJECT:
1284-001
Sheet
Of 15
VILLAGE COOPERATIVE OF FORT COLLINS
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
10/25/16
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
CS2
NOTES
GENERAL & CONSTRUCTION S. Thomas
A. Boese
N.T.S.
2
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
X
X
X
X
X X
X
X X X
FO
FO FO FO
FO FO
FO FO FO
FO FO
FO FO FO FO
G G G G G
G G
G G G
G G
G
G G
G G
G G
G
G
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS
D
D
CABLE
TELE
VAULT
ELEC
VAULT
ELEC ELEC
T S
VAULT
F.O.
VAULT
ELEC
VAULT
TELE
S
D
W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
FO
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
G G G G G G G G G G G G G G G G G G G G G G
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS SS SS SS SS
WV
S
STRACHAN 1ST
OWNER: ASPEN LEAF SPE LLC
N:113271.17
E:197261.59
FND 2" ALUM CAP
LS 24305
N:113235.02
E:197354.88
FND #4 REBAR
ILLEGIBLE
N:113222.20
E:197402.19
FND #4 REBAR
ILLEGIBLE
9' EX. UTILITY AND
ACCESS EASEMENT
TO BE VACATED
5' EX. DRAINAGE EASEMENT
TO BE VACATED
20' EX. EMERGENCY
ACCESS EASEMENT
TO BE VACATED
EX. DRAINAGE
EASEMENT
TO BE VACATED
EX. WATER AND
UTILITY EASEMENT
TO BE VACATED
57.5' HALF RIGHT OF WAY
HORSETOOTH ROAD
RIGHT OF WAY VARIES
107.5' TO 108.5'
REMOVE PAVEMENT
STRIPING REMOVE PAVEMENT
STRIPING
SAWCUT AND REMOVE 20 LF
CURB AND GUTTER
SAWCUT AND REMOVE 34 LF
EXISTING SIDEWALK
SAWCUT EDGE OF
ASPHALT 1' WIDE
AND REMOVE EXISTING
ASPHALT
RELOCATE EXISTING
SPEED LIMIT SIGN
EC2
AND DEMOLITION PLAN
EXISTING CONDITIONS S. Thomas
S. Thomas
1"=20'
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
FIRELANE
ONLY
FIRELANE
ONLY
PARKING
GARAGE
ENTRANCE
X
X
X
X
X X
X
X X X
FO
FO FO FO
FO FO
FO FO FO
FO FO
FO FO FO FO
G G G G G
G G
G G G
G G
G
G G
G G
G G
G
G
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS
CABLE
VAULT
ELEC
VAULT
ELEC ELEC
T S
VAULT
F.O.
S
D
W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
UD UD
FIRELANE
ONLY
FIRELANE
ONLY
PARKING
GARAGE
ENTRANCE
FO
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
G G G G G G G G G G G G G G G G G G G G G G
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS SS SS SS SS
WV
S
UD UD
FO
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
G G G G G G G G G G G G G G G G G G G G G G
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS SS SS SS SS
WV
S
STRACHAN 1ST
OWNER: ASPEN LEAF SPE LLC
N:113271.17
E:197261.59
FND 2" ALUM CAP
LS 24305
N:113235.02
E:197354.88
FND #4 REBAR
ILLEGIBLE
N:113222.20
E:197402.19
FND #4 REBAR
ILLEGIBLE
57.5' HALF RIGHT OF WAY
HORSETOOTH ROAD
RIGHT OF WAY VARIES
107.5' TO 108.5'
20' EMERGENCY
ACCESS EASEMENT
20' EMERGENCY
ACCESS AND DRAINAGE
EASEMENT
DRAINAGE
EASEMENT
CESS, AND DRAINAGE EASEMENT
15' UTILTY, ACCESS, AND DRAINAGE EASEMENT
\A1;15' UTILTY, ACCESS, AND DRAINAGE EASEMENT
3
4
3
3
"NO PARKING
FIRE LANE" "NO PARKING
FIRE LANE"
5' SIDEWALK
16'
X
X
X
X
X X
X
X X X
FO
FO FO FO
FO FO
FO FO FO
FO FO
FO FO FO FO
G G G G G
G G
G G G
G G
G
G G
G G
G G
G
G
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS
CABLE
VAULT
ELEC
VAULT
ELEC ELEC
T S
VAULT
F.O.
S
D
W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
G
G
G
G
FO
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
G G G G G G G G G G G G G G G G G G G G G G
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS SS SS SS SS
WV
S
UD UD
FO
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
G G G G G G G G G G G G G G G G G G G G G G
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS SS SS SS SS
WV
S
FO
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
G G G G G G G G G G G G G G G G G G G G G G
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS SS SS SS SS
WV
S
STRACHAN 1ST
OWNER: ASPEN LEAF SPE LLC
15' UTILITY, ACCESS AND
DRAINAGE EASEMENT
57.5' HALF RIGHT OF WAY
HORSETOOTH ROAD
PROJECT
BOUNDARY (TYP.)
PROPOSED
CURB INLET
PROPOSED
STORM DRAIN
PROPOSED
CURB INLET
PROPOSED STORMTECH
UNDERGROUND DETENTION
AND WATER QUALITY SYSTEM
PROPOSED
FES
PROPOSED OUTLET
STRUCTURE
PROPOSED
STORM DRAIN
N:113271.17
E:197261.59
FND 2" ALUM CAP
LS 24305
N:113235.02
E:197354.88
FND #4 REBAR
ILLEGIBLE
N:113222.20
E:197402.19
FND #4 REBAR
ILLEGIBLE
HORSETOOTH ROAD
RIGHT OF WAY VARIES
107.5' TO 108.5'
X
X
X
X
X X
X
X X X
FO
FO FO FO
FO FO
FO FO FO
FO FO
FO FO FO FO
G G G G G
G G
G G G
G G
G
G G
G G
G G
G
G
CABLE
VAULT
ELEC
VAULT
ELEC ELEC
T S
VAULT
F.O.
S
D
G
G
G
G
G
G
G
G
G
G
G G
G
G
G
G
G
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO FO
FO
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
G G G G G G G G G G G G G G G G G G G G G G
S
STRACHAN 1ST
OWNER: ASPEN LEAF SPE LLC
UD UD
FO
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
G G G G G G G G G G G G G G G G G G G G G G
S
FO
FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO
G G G G G G G G G G G G G G G G G G G G G G
S
PROPOSED
CURB INLET
PROPOSED
STORM DRAIN
PROPOSED
PROPOSED STORMTECH CURB INLET
UNDERGROUND DETENTION
AND WATER QUALITY SYSTEM
PROPOSED
FES
PROPOSED OUTLET
STRUCTURE
PROPOSED
STORM DRAIN
4:1
4:1
5:1
5:1
4:1
5:1
4:1
6:1
8:1
14.5%
4:1
5:1
5.2%
5:1
5.5%
2.0%
2.6%
2.6%
2.0%
6.5%
4.7%
11.2%
4.0%
2.7%
5.4%
2.4%
3.5%
4.7%
12.1%
8.2%
5.5%
CABLE
VAULT
ELEC
VAULT
ELEC
ELEC
T S
S
D
S
CABLE
VAULT
ELEC
VAULT
ELEC
ELEC
T S
S
D
S
HORSETOOTH ROAD
STANFORD ROAD
VERTICAL CURB
& GUTTER
PROPOSED STRIPING
SEE SHEET R3
EXISTING STRIPING
6' SIDEWALK
PROPOSED STORM DRAIN
EXISTING STORM DRAIN
EXISTING VERTICAL
CURB & GUTTER
108.3' ROW
(VARIES)
∆
4995
5000
5005
5010
5015
5020
4995
5000
5005
5010
5015
5020
9+50 10+00 11+00 12+00 13+00 14+00
4995
5000
5005
5010
5015
4995
5000
5005
5010
5015
4+50 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 14+00
96.0' VC
S S
F
IRELANE
ONLY
FIRELANE
ONLY
S S
U
UD D
TIE TO EXISTING
SIDEWALK
108.6' ROW
(VARIES)
STRACHAN 1ST
OWNER: ASPEN LEAF SPE LLC
PROPOSED STRIPING
SEE SHEET R3
EXISTING STRIPING
EXISTING VERTICAL
CURB & GUTTER
PROPOSED VERTICAL
CURB & GUTTER
6' SIDEWALK
HORSETOOTH ROAD
SPINDRIFT CT.
STOVER ST.
Horsetooth Proposed North Flowline
4995
5000
5005
5010
5015
5020
4995
5000
5005
5010
5015
5020
14+00 15+00 16+00 17+00 18+00 19+00
4995
5000
5005
5010
5015
4995
5000
5005
5010
5015
14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 23+50
5004.33
5004.75
5005.18
5005.60
5006.03
5006.45
5006.87
5007.23
5007.54
CABLE
VAULT
ELEC
VAULT
ELEC
ELEC
T S
S
D
S
CABLE
VAULT
ELEC
VAULT
ELEC
ELEC
T S
S
D
S
HORSETOOTH ROAD
STANFORD ROAD
EXISTING STRIPING
108.3' ROW
(VARIES)
108.3' ROW
(VARIES)
11' TRAVEL LANE
11' TRAVEL LANE
6' BIKE LANE
6' SIDEWALK
10' PARKWAY
11' TURN LANE
12' TURN LANE
12' TRAVEL LANE
EXISTING 12' TRAVEL LANE 12' TURN LANE
EXISTING 12' TRAVEL LANE
EXISTING 12' TRAVEL LANE
EXISTING 12' TRAVEL LANE
EXISTING 6' MEDIAN
EXISTING 11' TURN LANE
12.0'
11.0'
11.0'
6.0'
11.0'
10.0'
6.0'
A
A
B B
L
K
1
4
4
6
3
12
7
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
10+50
4990
4992
4996
5000
5004
5008
5012
4990
4992
4996
5000
5004
5008
5012
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
11+00
4990
4992
4996
5000
5004
5008
5012
4990
4992
4996
5000
5004
5008
5012
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
11+50
4990
4992
4996
5000
5004
5008
5012
4990
4992
4996
5000
5004
5008
5012
-100 -80 -60 -40 -20 0 20 40 60 80
UD
X
X
X
X
CABLE
VAULT
F.O.
D
ST
ST
X
X
X
X
CABLE
VAULT
F.O.
D
ST
ST
UD3
0.04 AC OS1
1.05 AC
A3
0.21 AC
A5
0.35 AC
B1
0.36 AC
A6
0.44 AC
A4
0.10 AC
A8
0.50 AC
A1
0.02 AC
C1
0.03 AC
A7
0.02 AC
A2
0.07 AC
OS2
0.07 AC
UD2
0.04 AC
UD1
0.03 AC
UD4
0.04 AC
B2
0.54 AC
PROPOSED
CURB INLET
PROPOSED
DRAIN BASIN
PROPOSED
CURB INLET
PROPOSED
CURB INLET
PROPOSED
CURB INLET
PROPOSED
OUTLET
STRUCTURE
EXISTING STORM
JUNCTION STRUCTURE
TO BE RECONFIGURED
PROPOSED
CURB INLET
AND WATER
QUALITY WEIR
PROPOSED STORMTECH
UNDERGROUND DETENTION
AND WATER QUALITY SYSTEM
PROPOSED
OUTLET
STRUCTURE
OS3
0.31 AC
1
2
3
4
5
6
BASIN A5 ROOF
DRAIN RELEASE
TO MANHOLE
7
8
9
10
11
12
DETENTION
POND B
DETENTION
POND A
STRACHAN 3RD
OWNER: ARENA I LLC AND ARENA II LLC
HORSETOOTH ROAD
RIGHT OF WAY VARIES
107.5' TO 108.5'
STRACHAN 3RD
OWNER: PETERSON-MOORE LLP
GREENLEE INVESTMENTS LLLP
STRACHAN 1ST
OWNER: ASPEN LEAF SPE LLC
STANFORD ROAD
98' RIGHT OF WAY
DR1
DRAINAGE PLAN
S. THOMAS
S. THOMAS
1"=40'
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner 15
( IN FEET )
0
1 INCH = 40 FEET
40 40 80 120
LEGEND:
5013
PROPOSED CONTOUR 93
EXISTING CONTOUR
PROPERTY BOUNDARY
EXISTING STORM SEWER
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2. REFER TO THE "PRELIMINARY DRAINAGE AND EROSION CONTROL REPORT FOR
THE VILLAGE COOPERATIVE OF FORT COLLINS" BY NORTHERN ENGINEERING,
DATED October 25th, 2016 FOR ADDITIONAL INFORMATION.
NOTES:
FLOW PATH
DRAINAGE BASIN BUBBLE
A
144 ac
DESIGN POINT A
BASIN BOUNDARY
PROPOSED STORM SEWER
FOR DRAINAGE REVIEW ONLY
NOT FOR CONSTRUCTION
No. Revisions:
By: Date:
REVIEWED BY:
N. HAWS
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
10/25/16
PROJECT:
1284-001
Sheet
Of 15
VILLAGE COOPERATIVE OF FORT COLLINS
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
10/25/16
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
KEYMAP
DRAINAGE SUMMARY TABLE
DESIGN
POINT
BASIN
ID
TOTAL
AREA
(acres)
C2 C100 2-yr
Tc
(min)
100-yr
Tc
(min)
Q2
(cfs)
Q100
(cfs)
1 A1 0.02 0.95 1.00 5.0 5.0 0.05 0.18
2 A2 0.07 0.33 0.41 5.0 5.0 0.07 0.30
3 A3 0.21 0.71 0.89 5.0 5.0 0.43 1.90
4 A4 0.10 0.76 0.95 5.0 5.0 0.22 0.94
5 A5 0.35 0.95 1.00 5.0 5.0 0.96 3.53
6 A6 0.44 0.75 0.93 5.9 5.0 0.90 4.06
7 A7 0.02 0.60 0.75 5.0 5.0 0.04 0.18
8 A8 0.50 0.26 0.33 7.7 7.1 0.32 1.44
9 C1 0.03 0.62 0.78 5.0 5.0 0.05 0.24
8 OS2 0.07 0.25 0.31 9.7 9.0 0.04 0.18
10 OS3 0.31 0.79 0.99 5.0 5.0 0.71 3.08
11 B1 0.36 0.95 1.00 5.0 5.0 0.99 3.62
11 B2 0.54 0.34 0.42 6.4 6.0 0.49 2.23
12 UD1 0.03 0.86 1.00 5.0 5.0 0.06 0.26
12 UD2 0.04 0.45 0.56 5.0 5.0 0.06 0.24
12 UD3 0.04 0.30 0.38 5.0 5.0 0.03 0.14
12 UD4 0.04 0.54 0.67 6.9 6.0 0.06 0.29
12 OS1 1.05 0.87 1.00 5.0 5.0 2.61 10.48
Detention Pond Summary | Proposed Condition
Pond 100-yr Volume
(ac-ft)
100-yr WSEL WQCV
(ft3)
WQCV WSEL Max Release
(cfs)
A 0.49 5005.67 336 4999.88 0.20
B 0.11 5003.76 496 5001.72 0.70
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
12+00
4990
4992
4996
5000
5004
5008
5012
4990
4992
4996
5000
5004
5008
5012
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
12+50
4996
5000
5004
5008
5012
5016
5020
4996
5000
5004
5008
5012
5016
5020
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
13+00
4994
4996
5000
5004
5008
5012
5016
4994
4996
5000
5004
5008
5012
5016
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
13+50
4994
4996
5000
5004
5008
5012
5016
4994
4996
5000
5004
5008
5012
5016
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
14+00
4996
5000
5004
5008
5012
5016
5020
4996
5000
5004
5008
5012
5016
5020
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
14+50
4996
5000
5004
5008
5012
5016
5020
4996
5000
5004
5008
5012
5016
5020
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
15+00
4994
4996
5000
5004
5008
5012
5016
4994
4996
5000
5004
5008
5012
5016
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
15+50
4990
4992
4996
5000
5004
5008
5012
5016
4990
4992
4996
5000
5004
5008
5012
5016
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
16+00
4994
4996
5000
5004
5008
5012
5016
4994
4996
5000
5004
5008
5012
5016
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
16+50
4994
4996
5000
5004
5008
5012
5016
5020
4994
4996
5000
5004
5008
5012
5016
5020
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
17+00
4998
5000
5004
5008
5012
5016
4998
5000
5004
5008
5012
5016
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
17+50
4998
5000
5004
5008
5012
5016
4998
5000
5004
5008
5012
5016
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
18+00
4998
5000
5004
5008
5012
5016
4998
5000
5004
5008
5012
5016
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
18+50
4998
5000
5004
5008
5012
5016
4998
5000
5004
5008
5012
5016
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
19+00
4998
5000
5004
5008
5012
5016
5020
4998
5000
5004
5008
5012
5016
5020
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
19+50
4998
5000
5004
5008
5012
5016
4998
5000
5004
5008
5012
5016
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
20+00
4998
5000
5004
5008
5012
5016
4998
5000
5004
5008
5012
5016
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
20+50
4998
5000
5004
5008
5012
5016
4998
5000
5004
5008
5012
5016
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
21+00
4998
5000
5004
5008
5012
5016
4998
5000
5004
5008
5012
5016
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
21+50
4998
5000
5004
5008
5012
4998
5000
5004
5008
5012
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
22+00
4998
5000
5004
5008
5012
4998
5000
5004
5008
5012
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
22+50
4998
5000
5004
5008
5012
4998
5000
5004
5008
5012
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
23+00
4998
5000
5004
5008
5012
4998
5000
5004
5008
5012
-100 -80 -60 -40 -20 0 20 40 60 80
SECTION
LINE
Horizontal Scale 1" = 50'
Vertical Scale 1" = 10'
23+50
4994
4996
5000
5004
5008
5012
4994
4996
5000
5004
5008
5012
-100 -80 -60 -40 -20 0 20 40 60 80
5003.5 5002.8 5002.3 5001.6 5001.0 5001.0
5008.1 5007.4 5006.6 5005.9 5005.1 5004.3
5010.6 5010.1 5010.1 5009.6 5009.2 5008.7
5006.7 5007.6 5008.5 5009.4 5010.1 5010.8
5004.0 5005.0 5005.8
(-2.0%)
(-2.3%)
(-3.4%)
(-0.5%)
EXISTING
GROUND (TYP.)
PROPOSED
GROUND (TYP.)
EXISTING
GROUND (TYP.)
PROPOSED
GROUND (TYP.)
EX. ROW
EX. ROW
FL=5000.19
-0.51%
EX. ROW
EX. ROW
FL=5000.03
-2.83%
EX. ROW
EX. ROW
FL=5000.28
-2.99%
EX. ROW
EX. ROW
FL=5000.66
-3.19%
EX. ROW
EX. ROW
FL=5001.35
-2.58%
EX. ROW
EX. ROW
FL=5002.20
-1.73%
EX. ROW
EX. ROW
FL=5003.05
-2.42%
EX. ROW
FL=5003.91
-1.93%
EX. ROW
EX. ROW
FL=5004.76
-1.83%
EX. ROW
EX. ROW
FL=5005.61
-2.65%
EX. ROW
EX. ROW
FL=5006.46
-2.27%
EX. ROW
EX. ROW
FL=5007.24
-3.12%
EX. ROW
EX. ROW
FL=5007.80
-2.30%
EX. ROW
EX. ROW
FL=5008.35
-4.55%
EX. ROW
EX. ROW
FL=5008.81
-2.89%
EX. ROW
FL=5009.13
-2.03%
EX. ROW
EX. ROW
FL=5009.88
3.05%
EX. ROW
EX. ROW
EX. ROW
EX. ROW
EX. ROW
EX. ROW
EX. ROW
EX. ROW
EX. ROW
EX. ROW
EX. ROW
EX. ROW
EX. ROW
EX. ROW
EX. ROW
EX. ROW
EX. ROW
EX. ROW
EX. ROW
EX. ROW
(-2.2%)
(-2.7%)
(-2.7%)
(-2.4%)
(-2.3%)
(-2.2%)
(-2.9%)
(-2.6%)
(-2.6%)
(-1.7%)
(-0.9%)
(-1.6%)
(-2.6%)
-14.5%
-25.3%
-18.3%
-25.1%
-24.1%
-16.3%
-14.4%
PROPOSED
SIDEWALK (TYP.)
PROPOSED
SIDEWALK (TYP.)
No. Revisions:
By: Date:
REVIEWED BY:
N. HAWS
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
10/25/16
PROJECT:
1284-001
Sheet
Of 15
VILLAGE COOPERATIVE OF FORT COLLINS
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
10/25/16
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
XS1
CROSS-SECTIONS
HORSETOOTH ROAD S. Thomas
A. Boese
1"=50'
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
14
7
STA.=13+30.50
OFFSET=33'
BEGIN 6
END 1
STA.=13+30.67
OFFSET=39'
BEGIN 3
END 4
STA.=12+88.69
OFFSET=12'
BEGIN 3
END 4
STA.=12+88.35
OFFSET=0'
BEGIN 7
STA.=10+32.12
OFFSET=11'
BEGIN 4
STA.=10+32.10
OFFSET=17'
STA.=10+31.26 BEGIN 4
OFFSET=28'
BEGIN 12
STA.=10+31.23
OFFSET=39'
BEGIN 1
STA.=10+31.22
OFFSET=45'
BEGIN 4
STA.=10+83.22
OFFSET=17'
PT 4
3
FIRELANE
ONLY
FIRELANE
ONLY
S S
U
D
S S
U
D
108.6' ROW
(VARIES)
STRACHAN 1ST
OWNER: ASPEN LEAF SPE LLC
EXISTING STRIPING
PROPOSED VERTICAL
CURB & GUTTER
6' SIDEWALK
11' TRAVEL LANE
11' TRAVEL LANE
8' BIKE LANE
6' SIDEWALK
10' PARKWAY
12' TURN LANE
12' TRAVEL LANE
10.7'
11.0'
8.0'
10.0'
6.0'
A A
L
6 1
3
3
12
7
STA.=19+02.62
OFFSET=5'
END 12
STA.=19+10.04
OFFSET=17'
END 1
STA.=17+92.40
OFFSET=14'
END 7
STA.=15+10.75
OFFSET=27'
BEGIN 1
END 6
STA.=15+10.92
OFFSET=33'
END 3
STA.=17+59.60
OFFSET=2'
PC 7
STA.=14+48.62
OFFSET=7'
END 3
STA.=14+52.37
OFFSET=7'
PT 7
STA.=14+44.88
OFFSET=7'
PC 7
TURN RIGHT
MUST
R3-7R
RIGHT LANE
30"
30"
No. Revisions:
By: Date:
REVIEWED BY:
N. HAWS
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
10/25/16
PROJECT:
1284-001
Sheet
Of 15
VILLAGE COOPERATIVE OF FORT COLLINS
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
10/25/16
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
R3
ROADWAY PLAN & PROFILE
HORSETOOTH ROAD S. Thomas
A. Boese
1"=40'
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
EXISTING RIGHT-OF-WAY
LEGEND:
PROPOSED STORM SEWER
EXISTING STORM SEWER
EXISTING EDGE OF ASPHALT
PROPOSED STORM MANHOLE
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PEDESTRIAN ACCESS RAMPS
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
PROPOSED STORM INLET
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
13
LINE
MATCH STA
14+00
LINE
MATCH STA
14+00
10 YELLOW ISLAND CROSS HATCHING
WHITE ISLAND CROSS HATCHING
4" SOLID YELLOW LINE
4" SOLID WHITE LINE
(2) 4" SOLID LINES; 4" APART
DOUBLE YELLOW LINE
4" BROKEN YELLOW LINE
8" SOLID WHITE LINE
DOUBLE YELLOW LINE
4" SOLID AND 4" BROKEN; 4" APART
9
6
3
5
1
8
2
4
7
STRAIGHT AND RIGHT TURN ARROW (31 S.F. EA.)
PREFORMED PLASTIC PAVEMENT MARKING
BICYCLIST AND ARROW
18" X 12' CROSSING LINE, SEE NOTES
PREFORMED PLASTIC PAVEMENT MARKING
PREFORMED PLASTIC PAVEMENT MARKING
18" WIDE STOP BAR
PREFORMED PLASTIC PAVEMENT
MARKING "STOP" (22.5 S.F. EA.)
PREFORMED PLASTIC PAVEMENT MARKING
STRAIGHT AND LEFT TURN ARROW (31 S.F. EA.)
PREFORMED PLASTIC PAVEMENT MARKING
PREFORMED PLASTIC PAVEMENT MARKING
RIGHT TURN ARROW (15.5 S.F. EA.)
PREFORMED PLASTIC PAVEMENT MARKING
LEFT TURN ARROW (15.5 S.F. EA.)
RIGHT AND LEFT TURN ARROW (31 S.F. EA.)
PREFORMED PLASTIC PAVEMENT MARKING
TWO WAY LEFT TURN ARROW (31 S.F. EA.)
PREFORMED PLASTIC PAVEMENT MARKING
PREFORMED PLASTIC PAVEMENT
MARKING "ONLY" (22.5 S.F. EA.)
L
H
D
C
B
A K
E
F
G
I
J
M LANE REDUCTION ARROW
PREFORMED PLASTIC PAVEMENT MARKING
11 MEDIAN LINE YELLOW 18" WIDE
50' O.C. 45° ANGLES
10' 30' 10' 30' 10' 12 4" BROKEN WHITE 10'
N "LANE ENDS"
PREFORMED PLASTIC PAVEMENT MARKING
4" WHITE EXTENSION LINE 3' 9' 3' 9' 3'
O 18" WIDE WHITE MEDIAN STRIPING
PREFORMED PLASTIC PAVEMENT MARKING
A. ALL SIGNAGE AND MARKING IS SUBJECT TO THE TRAFFIC SIGNING AND PAVEMENT
MARKING CONSTRUCTION NOTES ON SHEET CS1 OF THESE PLANS, AS WELL AS
THE TRAFFIC SIGNING AND MARKING CONSTRUCTION NOTES LISTED HERE.
B. SIGNAGE AND STRIPING HAS BEEN DETERMINED BY INFORMATION AVAILABLE AT
THE TIME OF REVIEW. PRIOR TO INITIATION OF THE WARRANTY PERIOD. THE CITY
OF FORT COLLINS RESERVES THE RIGHT TO REQUIRE ADDITIONAL SIGNAGE
AND/OR STRIPING IF THE CITY OF FORT COLLINS DETERMINES THAT AN
UNFORESEEN CONDITION WARRANTS SUCH SIGNAGE ACCORDING TO THE MUTCD
OR THE CDOT M AND S STANDARDS. ALL SIGNAGE AND STRIPING SHALL FALL
UNDER THE REQUIREMENTS OF THE 2-YEAR WARRANTY PERIOD FOR NEW
CONSTRUCTION (EXCEPT FAIR WEAR ON TRAFFIC MARKINGS).
C. STREET NAME SIGNS AT INTERSECTIONS SHALL BE INSTALLED ABOVE STOP SIGNS
ON SAME POLE, PER LCUASS DRAWING 1401.
STRIPING LEGEND:
STRIPING NOTES:
8" WHITE EXTENSION LINE 3' 9' 3' 9' 3'
(NOTE: ALL ITEMS MAY NOT APPLY TO THIS PLAN)
PAVEMENT STRIPING
PAVEMENT MARKINGS
STRAIGHT ARROW (15 S.F. EA.)
PREFORMED PLASTIC PAVEMENT MARKING
30' 10' 30' 10'
L
( IN FEET )
0
1 INCH = 40 FEET
40 40 80 120
KEYMAP
R3 R3
5007.79
5008.04
5008.34
5008.60
5008.81
5008.95
5009.13
5009.38
5009.84
EXISTING
GROUND
EXISTING
GROUND
EXISTING
GROUND
PROPOSED
GRADE
EXISTING
GROUND
PROPOSED
GRADE
1.70%
0.50%
1.03%
2.45%
0.94%
1.26%
PVI STA = 16+72.21
PVI ELEV = 5008.00
PVI STA = 18+35.28
PVI ELEV = 5009.48
PVI STA = 18+55.90
PVI ELEV = 5009.99
83.7' VC
PVI STA = 16+02.62
PVI ELEV = 5007.35
BVCS: 15+60.79
BVCE: 5006.64
EVCS: 16+44.45
EVCE: 5007.74
A.D. = 0.76
K = 110.00
83.2' VC
PVI STA = 17+30.48
PVI ELEV = 5008.73
BVCS: 16+88.88
BVCE: 5008.21
EVCS: 17+72.08
EVCE: 5008.94
A.D. = 0.76
K = 110.00
31.6' VC
PVI STA = 17+91.94
PVI ELEV = 5009.04
BCVS: 17+76.12
BVCE: 5008.96
ECVS: 18+07.76
EVCE: 5009.20
A.D. = 0.53
K = 60.00
No. Revisions:
By: Date:
REVIEWED BY:
N. HAWS
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
10/25/16
PROJECT:
1284-001
Sheet
Of 15
VILLAGE COOPERATIVE OF FORT COLLINS
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
10/25/16
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
R2
ROADWAY PLAN & PROFILE
HORSETOOTH ROAD S. Thomas
A. Boese
1"=40'
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
EXISTING RIGHT-OF-WAY
LEGEND:
PROPOSED STORM SEWER
EXISTING STORM SEWER
EXISTING EDGE OF ASPHALT
PROPOSED STORM MANHOLE
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PEDESTRIAN ACCESS RAMPS
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1
4" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING
OF 50 FEET.
5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
PROPOSED STORM INLET
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
12
LEFT FLOWLINE
HORSETOOTH ROAD
SCALE : 1" = 40' (H) 1" = 5' (V)
CENTERLINE
HORSETOOTH ROAD
SCALE : 1" = 40' (H) 1" = 5' (V)
LINE
MATCH STA
14+00
( IN FEET )
0
1 INCH = 40 FEET
40 40 80 120
KEYMAP
R1 R2
MATCH LINE SEE SHEET STA 14+00 MATCH LINE SEE SHEET R1 STA 14+00
R1
PVI STA = 12+02.61
PVI ELEV = 5000.55
BCVS: 11+54.61
BVCE: 5000.31
ECVS: 12+50.61
EVCE: 5001.36
A.D. = 1.20
K = 80.00
EXISTING
GROUND
PROPOSED
GRADE
PROPOSED
GRADE
EXISTING
GROUND
EXISTING
GROUND
EXISTING
GROUND
EXISTING 3-44"x28'' ARCH STORM
STA.=10+62.77
INV.±4996.7
0.50%
1.70%
-3.66%
-2.00%
PVI STA = 10+00.00
PVI ELEV = 5001.87
PVI STA = 10+40.92
PVI ELEV = 5000.37
PVI STA = 10+66.28
PVI ELEV = 4999.86
EXISTING STORM
JUNCTION STRUCTURE
5001.87
5000.95
5000.19
4999.91
5000.03
5000.16
5000.28
5000.43
5000.66
5000.97
5001.35
5001.78
5002.20
5002.63
5003.05
5003.48
No. Revisions:
By: Date:
REVIEWED BY:
N. HAWS
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
10/25/16
PROJECT:
1284-001
Sheet
Of 15
VILLAGE COOPERATIVE OF FORT COLLINS
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
10/25/16
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
R1
ROADWAY PLAN & PROFILE
HORSETOOTH ROAD S. Thomas
A. Boese
1"=40'
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
0
1 INCH = 40 FEET
40 40 80 120
EXISTING RIGHT-OF-WAY
LEGEND:
PROPOSED STORM SEWER
EXISTING STORM SEWER
EXISTING EDGE OF ASPHALT
PROPOSED STORM MANHOLE
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PEDESTRIAN ACCESS RAMPS
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1
4" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING
OF 50 FEET.
5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
PROPOSED STORM INLET
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
11
LEFT FLOWLINE
HORSETOOTH ROAD
SCALE : 1" = 40' (H) 1" = 5' (V)
CENTERLINE
HORSETOOTH ROAD
SCALE : 1" = 40' (H) 1" = 5' (V)
MATCH LINE SEE SHEET R2 STA 14+00 MATCH LINE STA
SEE SHEET R2 14+00
LINE
MATCH STA
14+00
KEYMAP
R1 R2
12.5%
2.1%
6.1%
3.8%
57.5' HALF RIGHT OF WAY
20' EMERGENCY
ACCESS EASEMENT
20' EMERGENCY
ACCESS AND DRAINAGE
EASEMENT
DRAINAGE
EASEMENT
CESS, AND DRAINAGE EASEMENT 15' UTILTY, ACCESS, AND
DRAINAGE EASEMENT
LANDSCAPE
RETAINING WALL
2.5' MAX HEIGHT
LANDSCAPE
RETAINING WALL
2.5' MAX HEIGHT
STEPS
GARDEN
BOXES
N:113271.17
E:197261.59
FND 2" ALUM CAP
LS 24305
N:113235.02
E:197354.88
FND #4 REBAR
ILLEGIBLE
N:113222.20
E:197402.19
FND #4 REBAR
ILLEGIBLE
HORSETOOTH ROAD
RIGHT OF WAY VARIES
107.5' TO 108.5'
DETENTION
POND A
PROPOSED
CURB INLET
PROPOSED
STORM DRAIN
7.00
7.00
7.00
7.00
No. Revisions:
By: Date:
REVIEWED BY:
N. HAWS
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
10/25/16
PROJECT:
1284-001
Sheet
Of 15
VILLAGE COOPERATIVE OF FORT COLLINS
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
10/25/16
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
G2
GRADING PLAN
S. Thomas
A. Boese
1"=20'
10
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
MATCHLINE-SEE SHEET G1
LEGEND:
5013
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB AND GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION 33.43
PROPOSED SLOPES
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD88.
SEE COVER SHEET FOR BENCHMARK REFERENCE.
4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS
REQUIRED FOR PROTECTION FROM THE 100-YR STORM.
NOTES:
PROPOSED STORM INLET
PEDESTRIAN ACCESS RAMPS
EXISTING SPOT ELEVATION
PROPOSED FIRE HYDRANT
PROPOSED LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
EXISTING RIGHT OF WAY
PROPOSED RIGHT OF WAY
(33.43)
PROPOSED SLOPES 4:1
KEYMAP
G1 G2
FO
FO
FO
FO
FO
STRACHAN 1ST
OWNER: ASPEN LEAF SPE LLC
STRACHAN 3RD
OWNER: ARENA I LLC AND ARENA II LLC
STRACHAN 3RD
OWNER: PETERSON-MOORE LLP
GREENLEE INVESTMENTS LLLP
S
X
X
X
X
X X
X
X X X
FO
FO FO FO
FO FO
FO FO FO
FO FO
FO FO FO FO
G G G G G
G G
G G G
G G
G
G G
G G
G G
G
G
CABLE
VAULT
ELEC
VAULT
ELEC ELEC
T S
VAULT
F.O.
S
D
G
G
G
G
G
G
G
G
G
G
G G
G
G
G
G
G
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO FO
FO
FO
FO
FO
FO
X
X
X
X
X X
X
X X X
FO
FO FO FO
FO FO
FO FO FO
FO FO
FO FO FO FO
G G G G G
G G
G G G
G G
G
G G
G G
G G
G
G
CABLE
VAULT
ELEC
VAULT
ELEC ELEC
T S
VAULT
F.O.
S
D
G
G
G
G
G
G
G
G
G
G
G G
G
G
G
G
G
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO FO
FO
FO
FO
FO
FO
PROPOSED
CURB INLET
PROPOSED
DRAIN BASIN
PROPOSED
CURB INLET
PROPOSED
CURB INLET
PROPOSED
CURB INLET
PROPOSED
CURB INLET
PROPOSED
OUTLET
STRUCTURE
EXISTING JUNCTION
STRUCTURE TO BE
RELOCATED,
RECONSTRUCTED OR
LEFT IN PLACE
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN
PROPOSED
PROPOSED STORMTECH CURB INLET
UNDERGROUND DETENTION
AND WATER QUALITY SYSTEM
PROPOSED
STORM DRAIN
14.5%
4:1
5:1
5.2%
5:1
5.5%
4.0%
2.7%
5.4%
2.4%
3.5%
4.7%
12.1%
8.2%
5:1
5:1
5:1
5:1
6:1
4:1
3:1
4:1
4:1
6:1
5:1
3:1
6:1
6:1
7:1
5.5%
4.1%
2.9%
2.6%
1.4%
3.7%
3.6%
3.3%
1.6%
2.1%
2.5%
2.3%
2.1%
3.2%
4.4%
5.2%
3.7%
5.0%
4.5%
4.6%
8.9%
5.1%
16.0%
13.5%
6.2%
5.7%
8.8%
3.4%
3:1
4:1
4.0%
4.8%
5.1%
2.0%
FFE=16.66
FFE=16.66
2' WIDE CURB
CHASE
5.3%
5.3%
4.8%
4.0%
5.5%
3.7%
6.1%
3.8%
PROPOSED
ROOF
DRAIN
1' WIDE
SIDEWALK
CHASE
20' EX. SANITARY
SEWER EASEMENT
9' EX. UTILITY AND
ACCESS EASEMENT
EX. SIGHT DISTANCE
EASEMENT
30' EMERGENCY
ACCESS
EASEMENT
24' EMERGENCY
ACCESS EASEMENT
20' EMERGENCY
ACCESS EASEMENT
15' UTILTY, ACCESS, AND DRAINAGE EASEMENT
10' DRAINAGE EASEMENT
N:113449.14
E:196923.80
FND #4 REBAR W/
WPC ILLEGIBLE
N:113423.03
E:196654.22
FND #4 REBAR
W/ WPC ILLEGIBLE
N:113529.92
E:196713.26
FND #4 REBAR
W/ WPC ILLEGIBLE
N:113239.19
E:196590.45
FND #4 REBAR
NO CAP
HORSETOOTH ROAD
RIGHT OF WAY VARIES
107.5' TO 108.5'
STANFORD ROAD
98' RIGHT OF WAY
UTILITY AND DRAINAGE
EASEMENT
58.5' HALF RIGHT OF WAY
DETENTION
POND B
4:1
LANDSCAPE RETAINING
WALL. MAX HEIGHT 2.5'
16.00
16.66
7.00
7.00
7.00
7.00
No. Revisions:
By: Date:
REVIEWED BY:
N. HAWS
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
10/25/16
PROJECT:
1284-001
Sheet
Of 15
VILLAGE COOPERATIVE OF FORT COLLINS
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
10/25/16
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
G1
GRADING PLAN
S. Thomas
A. Boese
1"=20'
9
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
MATCHLINE-SEE SHEET G2
LEGEND:
5013
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB AND GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION 33.43
PROPOSED SLOPES
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD88.
SEE COVER SHEET FOR BENCHMARK REFERENCE.
4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS
REQUIRED FOR PROTECTION FROM THE 100-YR STORM.
NOTES:
PROPOSED STORM INLET
PEDESTRIAN ACCESS RAMPS
EXISTING SPOT ELEVATION
PROPOSED FIRE HYDRANT
PROPOSED LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
EXISTING RIGHT OF WAY
PROPOSED RIGHT OF WAY
(33.43)
PROPOSED SLOPES 4:1
KEYMAP
G1 G2
20' EMERGENCY
ACCESS EASEMENT
20' EMERGENCY
ACCESS AND DRAINAGE
EASEMENT
DRAINAGE
EASEMENT
PROPOSED
STORM DRAIN
PROPOSED
CURB INLET
KEYMAP
No. Revisions:
By: Date:
REVIEWED BY:
N. HAWS
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
10/25/16
PROJECT:
1284-001
Sheet
Of 15
VILLAGE COOPERATIVE OF FORT COLLINS
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
10/25/16
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
U2
UTILITY PLAN
S. Thomas
A. Boese
1"=20'
8
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
MATCHLINE-SEE SHEET U1
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS
UTILITIES SPECIFICATIONS LATEST EDITION.
3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS AND SERVICES.
6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED
IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
8. MINIMUM COVER OF 4.5' SHALL BE MAINTAINED THROUGHOUT THE WATERLINE AND
SERVICE LINE INSTALLATION. MAXIMUM ALLOWED COVER SHALL BE 6' UNLESS
SPECIFICALLY APPROVED BY THE CITY.
EXISTING STORM SEWER
EXISTING ELECTRIC
EXISTING TELEPHONE
EXISTING GAS
EXISTING ELECTRIC METER
EXISTING WATER METER
EXISTING IRRIGATION BOX
EXISTING POWER POLE
EXISTING TELEPHONE PEDESTAL
EXISTING TREES
EXISTING SANITARY SEWER
PROPOSED STORM INLET
EXISTING LIGHT POLE
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT H Y
D
PROPOSED LOTLINE
EASEMENT LINE
COWNTROL
IRR
W S
O
E
PROPERTY BOUNDARY
S
PROPOSED SEWER SERVICE
PROPOSED RESIDENTIAL WATER SERVICE
EXISTING GAS METER G
W
U1 U2
G
G
G
G
G
G
G G
G
G
G
G
G
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO FO
FO
FO
FO
FO
FO
W W
FDC
W
F
S
X
X
X
X
X X
X
X X X
FO
FO FO FO
FO FO
FO FO FO
FO FO
FO FO FO FO
G G G G G
G G
G G G
G G
G
G G
G G
G G
G
G
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS
C
ABLE
VAULT
ELEC
VAULT
ELEC ELEC
T S
VAULT
F.O.
S
D
W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
G
G
G
G
G
G
G
G
G
G
G G
G
G
G
G
G
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO FO
FO
FO
FO
FO
FO
W W
X
X
X
X
X X
X
X X X
FO
FO FO FO
FO FO
FO FO FO
FO FO
FO FO FO FO
G G G G G
G G
G G G
G G
G
G G
G G
G G
G
G
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS
C
ABLE
VAULT
ELEC
VAULT
ELEC ELEC
T S
VAULT
F.O.
S
D
W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
G
G
G
G
G
G
G
G
G
G
G G
G
G
G
G
G
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO FO
FO
FO
FO
FO
FO
W W
STRACHAN 1ST
OWNER: ASPEN LEAF SPE LLC
STRACHAN 3RD
OWNER: ARENA I LLC AND ARENA II LLC
STRACHAN 3RD
OWNER: PETERSON-MOORE LLP
GREENLEE INVESTMENTS LLLP
78' ROW
60'
FL-FL
20' EX. SANITARY
SEWER EASEMENT
15' UTILITY, ACCESS, AND
DRAINAGE EASEMENT
9' EX. UTILITY AND
ACCESS EASEMENT
PROJECT
BOUNDARY (TYP.)
PROPOSED
FIRE HYDRANT
PROPOSED FIRE
SERVICE
PROPOSED APPROX. 3"
DOMESTIC WATER METER WITH
CURB STOP
70.03± APPROX. 3" WATER SERVICE
N57°31'15"W
69.21± 6" PVC FIRELINE
S57°31'15"E
50.44 LF 6" PVC
N53°09'11"W
EX. SIGHT DISTANCE
EASEMENT
CONNECT TO
EXISTING WATER MAIN
12"x6" WET
CONNECTION w/TB
AND GV
CONNECT TO
EXISTING WATER MAIN
12"x6" WET
CONNECTION w/ TB
AND GV
CONNECT TO
EXISTING WATER MAIN
3" WET TAP
CONNECT TO EXISTING
SANITARY SEWER
57.45± @ 2.0 % APPROX. 6" PVC
N00°21'48"E SANITARY SERVICE
SANITARY SEWER SERVICE
PROPOSED
CURB INLET
PROPOSED
DRAIN BASIN
PROPOSED
CURB INLET
PROPOSED
CURB INLET
PROPOSED
CURB INLET
PROPOSED
CURB INLET
PROPOSED
OUTLET
STRUCTURE
EXISTING JUNCTION
STRUCTURE TO BE
RELOCATED,
RECONSTRUCTED, OR
LEFT IN PLACE.
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN
PROPOSED
CURB INLET
PROPOSED STORMTECH
UNDERGROUND DETENTION
AND WATER QUALITY SYSTEM
PROPOSED
STORM DRAIN
N:113449.14
E:196923.80
FND #4 REBAR W/
WPC ILLEGIBLE
N:113529.92
E:196713.26
FND #4 REBAR
W/ WPC ILLEGIBLE
N:113239.19
E:196590.45
FND #4 REBAR
NO CAP
HORSETOOTH ROAD
RIGHT OF WAY VARIES
107.5' TO 108.5'
STANFORD ROAD
78' RIGHT OF WAY
58.5' HALF RIGHT OF WAY
30' EMERGENCY ACCESS EASEMENT
24' EMERGENCY
ACCESS EASEMENT
20' EMERGENCY
ACCESS EASEMENT
ROOF DRAIN
10' DRAINAGE EASEMENT
DRAINAGE
EASEMENT
UTILITY AND DRAINAGE
EASEMENT
EX. 12" WATERMAIN
EX. 8" SANITARY
SEWER
No. Revisions:
By: Date:
REVIEWED BY:
N. HAWS
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
10/25/16
PROJECT:
1284-001
Sheet
Of 15
VILLAGE COOPERATIVE OF FORT COLLINS
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
10/25/16
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
U1
UTILITY PLAN
S. Thomas
A. Boese
1"=20'
7
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
MATCHLINE-SEE SHEET U2
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS
UTILITIES SPECIFICATIONS LATEST EDITION.
3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS AND SERVICES.
6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED
IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
8. MINIMUM COVER OF 4.5' SHALL BE MAINTAINED THROUGHOUT THE WATERLINE AND
SERVICE LINE INSTALLATION. MAXIMUM ALLOWED COVER SHALL BE 6' UNLESS
SPECIFICALLY APPROVED BY THE CITY.
EXISTING STORM SEWER
EXISTING ELECTRIC
EXISTING TELEPHONE
EXISTING GAS
EXISTING ELECTRIC METER
EXISTING WATER METER
EXISTING IRRIGATION BOX
EXISTING POWER POLE
EXISTING TELEPHONE PEDESTAL
EXISTING TREES
EXISTING SANITARY SEWER
PROPOSED STORM INLET
EXISTING LIGHT POLE
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT H Y
D
PROPOSED LOTLINE
EASEMENT LINE
COWNTROL
IRR
W S
O
E
PROPERTY BOUNDARY
S
PROPOSED SEWER SERVICE
PROPOSED RESIDENTIAL WATER SERVICE
EXISTING GAS METER G
W
KEYMAP
U1 U2
"NO PARKING
FIRE LANE"
"RIGHT LANE MUST
TURN RIGHT"
"FIRELANE ONLY"
"FIRELANE ONLY"
"FIRELANE ONLY"
4
4 3
"NO PARKING
FIRE LANE"
LANDSCAPE
RETAINING WALL
2.5' MAX HEIGHT
LINE TABLE
LINE
L1
L4
L6
L7
L8
L10
L11
L13
L15
L16
L17
L19
L21
L22
L23
L25
LENGTH
45.21'
1.45'
15.00'
72.38'
13.50'
13.50'
45.51'
108.35'
117.71'
16.95'
45.64'
41.27'
6.21'
17.91'
46.32'
5.52'
BEARING
S69°51'56.64"E
S69°00'32.13"E
N20°59'27.87"E
S69°00'32.13"E
S20°59'27.87"W
N20°59'27.87"E
S69°00'32.13"E
S62°03'59.24"E
S00°12'50.10"W
S21°08'11.87"W
S83°02'29.42"E
N69°00'32.13"W
S69°00'32.13"E
S21°08'11.87"W
S69°51'56.64"E
S07°58'05.04"W
LINE TABLE
LINE
L27
L28
L29
L31
L35
L36
L38
L40
L42
L43
L44
L45
L46
L47
L49
L51
LENGTH
21.21'
30.00'
60.97'
149.14'
20.37'
1.08'
49.16'
20.05'
22.01'
32.96'
70.12'
16.05'
16.05'
13.90'
29.12'
6.50'
BEARING
N61°01'32.26"W
S28°58'27.74"W
S61°01'32.26"E
S83°02'29.42"E
N60°00'00.00"E
N60°00'00.00"E
S62°03'59.24"E
S00°12'50.10"W
N89°47'09.90"W
S89°47'09.90"E
S00°12'50.10"W
S00°12'50.10"W
S00°12'50.10"W
N51°58'13.33"E
S61°01'32.26"E
N28°58'27.74"E
CURVE TABLE
CURVE
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C12
C14
C15
C16
C17
C18
DELTA
50°09'52"
49°18'27"
90°00'00"
180°00'00"
6°56'33"
62°16'49"
165°58'03"
89°51'16"
44°44'38"
112°06'18"
90°08'44"
77°50'02"
111°00'23"
22°00'57"
27°09'03"
9°48'27"
RADIUS
49.00'
4.00'
3.00'
4.50'
218.00'
50.00'
4.00'
2.00'
24.00'
5.00'
2.00'
25.00'
12.00'
50.00'
30.00'
30.00'
LENGTH
42.90'
3.44'
4.71'
14.14'
26.41'
54.35'
11.59'
3.14'
18.74'
9.78'
3.15'
33.96'
23.25'
19.21'
14.22'
5.14'
BEARING
S44°47'01"E
S44°21'19"E
N65°59'28"E
S69°00'32"E
S65°32'16"E
S30°55'35"E
N13°58'29"E
S66°03'50"W
N23°29'09"W
N54°56'19"E
S23°56'10"E
S30°56'56"E
S63°28'16"W
S72°02'01"E
N83°22'59"E
N64°54'14"E
CHORD
41.54'
3.34'
4.24'
9.00'
26.40'
51.71'
7.94'
2.82'
18.27'
8.30'
2.83'
31.41'
19.78'
19.09'
14.08'
5.13'
CURVE TABLE
CURVE
C19
C20
C21
C22
C23
DELTA
57°56'01"
62°16'49"
90°00'00"
67°00'14"
90°00'00"
RADIUS
15.00'
30.00'
10.00'
20.00'
10.00'
LENGTH
15.17'
32.61'
15.71'
23.39'
15.71'
BEARING
N88°58'00"E
S30°55'35"E
S45°12'50"W
N85°28'21"E
N73°58'28"E
CHORD
14.53'
31.03'
14.14'
22.08'
14.14'
2
2
LANDSCAPE
RETAINING WALL
2.5' MAX HEIGHT
STEPS
GARDEN
BOXES
HC2
HORIZONTAL CONTROL PLAN
S. Thomas
S. Thomas
1"=20'
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
6
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
MATCHLINE-SEE SHEET HC1
No. Revisions:
By: Date:
REVIEWED BY:
N. HAWS
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
10/25/16
PROJECT:
1284-001
Sheet
Of 15
VILLAGE COOPERATIVE OF FORT COLLINS
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
10/25/16
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
LEGEND:
1. CURVES AND LINES ARE MEASURED AT FLOWLINE, CENTERLINE OR EDGE OF
WALK.
2. ATTACHED WALK WIDTHS ARE FROM FLOWLINE OF CURB & GUTTER.
3. ALL PARKING STRIPE SHALL BE 4" WHITE OR PER MUTCD.
4. SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND
PAVEMENT SECTIONS.
5. SEE GEOTECHNICAL REPORT FOR SUBGRADE PREPARATION AND PAVEMENT
RECOMMENDATIONS.
6. REFER TO SITE AND LANDSCAPE PLANS FOR PAVERS, DECORATIVE PAVING,
SCORING, ETC.
NOTES:
STANDARD ACCESS RAMP S
CURB AND GUTTER
DIRECTIONAL ACCESS RAMP D
X' PAN PX
CORNER APPROACH ACCESS RAMP C
VERTICAL CURB AND GUTTER
MONOLITHIC OUTFALL CURB, PARKING & GUTTER
18" INFALL CURB AND GUTTER
18" OUTFALL VERTICAL CURB AND GUTTER
1
2
3
4
KEYMAP
HC1 HC2
W
W
W
G
G
G
G
G
G
G
G
G
G
G G
G
G
G
G
G
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO FO
FO
FO
FO
FO
FO
W W
X
X
X
X
X X
X
X X X
FO
FO FO FO
FO FO
FO FO FO
FO FO
FO FO FO FO
G G G G G
G G
G G G
G G
G
G G
G G
G G
G
G
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS
C
ABLE
VAULT
ELEC
VAULT
ELEC ELEC
T S
VAULT
F.O.
S
D
W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
G
G
G
G
G
G
G
G
G
G
G G
G
G
G
G
G
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO FO
FO
FO
FO
FO
FO
W W
STRACHAN 1ST
OWNER: ASPEN LEAF SPE LLC
N:113449.14
E:196923.80
FND #4 REBAR W/
WPC ILLEGIBLE
STRACHAN 3RD
OWNER: ARENA I LLC AND ARENA II LLC
HORSETOOTH ROAD
RIGHT OF WAY VARIES
107.5' TO 108.5'
STANFORD ROAD
78' RIGHT OF WAY
STRACHAN 3RD
OWNER: PETERSON-MOORE LLP
GREENLEE INVESTMENTS LLLP
PRIVATE DRIVE
N:113423.03
E:196654.22
FND #4 REBAR
W/ WPC ILLEGIBLE
N:113529.92
E:196713.26
FND #4 REBAR
W/ WPC ILLEGIBLE
N:113239.19
E:196590.45
FND #4 REBAR
NO CAP
20' EX. SANITARY
SEWER EASEMENT
9' EX. UTILITY AND
ACCESS EASEMENT
EX. SIGHT DISTANCE
EASEMENT
58.5' HALF RIGHT OF WAY
30' EMERGENCY ACCESS EASEMENT
24' EMERGENCY
ACCESS EASEMENT
20' EMERGENCY
ACCESS EASEMENT
15' UTILTY, ACCESS, AND DRAINAGE EASEMENT
10' DRAINAGE EASEMENT
DRAINAGE
EASEMENT
UTILITY AND DRAINAGE
EASEMENT
4
C
4
3
3
4
4
4
3
4
3
3
3
HC PARKING
HC PARKING
"NO PARKING
FIRE LANE"
"NO PARKING
FIRE LANE"
"NO PARKING
FIRE LANE" "NO PARKING
FIRE LANE"
9' (TYP.)
18' (TYP.)
9' (TYP.)
18' (TYP.)
8'
8'
8'
S
"NO PARKING
FIRE LANE"
6.5' SIDEWALK
6.5' SIDEWALK
5' SIDEWALK
5' SIDEWALK
5' SIDEWALK
6' SIDEWALK
5' SIDEWALK
16'
"NO PARKING
FIRE LANE"
5' SIDEWALK
6.5' SIDEWALK
BIKE RACK
"FIRELANE ONLY"
"FIRELANE ONLY"
4
24' DRIVE LANE
4
LANDSCAPE
RETAINING WALL
2.5' MAX HEIGHT
2
2
5' SIDEWALK
D
2' WIDE
CURB CHASE
HC1
HORIZONTAL CONTROL PLAN
S. Thomas
S. Thomas
1"=20'
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
5
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
MATCHLINE-SEE SHEET HC2
No. Revisions:
By: Date:
REVIEWED BY:
N. HAWS
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
10/25/16
PROJECT:
1284-001
Sheet
Of 15
VILLAGE COOPERATIVE OF FORT COLLINS
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
10/25/16
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
LEGEND:
1. CURVES AND LINES ARE MEASURED AT FLOWLINE, CENTERLINE OR EDGE OF
WALK.
2. ATTACHED WALK WIDTHS ARE FROM FLOWLINE OF CURB & GUTTER.
3. ALL PARKING STRIPE SHALL BE 4" WHITE OR PER MUTCD.
4. SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND
PAVEMENT SECTIONS.
5. SEE GEOTECHNICAL REPORT FOR SUBGRADE PREPARATION AND PAVEMENT
RECOMMENDATIONS.
6. REFER TO SITE AND LANDSCAPE PLANS FOR PAVERS, DECORATIVE PAVING,
SCORING, ETC.
NOTES:
STANDARD ACCESS RAMP S
CURB AND GUTTER
DIRECTIONAL ACCESS RAMP D
X' PAN PX
CORNER APPROACH ACCESS RAMP C
VERTICAL CURB AND GUTTER
MONOLITHIC OUTFALL CURB, PARKING & GUTTER
18" INFALL CURB AND GUTTER
18" OUTFALL VERTICAL CURB AND GUTTER
1
2
3
4
KEYMAP
HC1 HC2
Know what's below.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
4
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
MATCHLINE-SEE SHEET EC1
No. Revisions:
By: Date:
REVIEWED BY:
N. HAWS
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
10/25/16
PROJECT:
1284-001
Sheet
Of 15
VILLAGE COOPERATIVE OF FORT COLLINS
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
10/25/16
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
EXISTING ELECTRIC E
LEGEND:
G
T
EXISTING STORM SEWER
ST
EXISTING TELEPHONE
EXISTING GAS
EXISTING IRRIGATION BOX
EXISTING GAS METER
EXISTING TELEPHONE PEDESTAL
EXISTING TREES (TO REMAIN)
FIELD SURVEY BY:
SUBSURFACE EXPLORATION BY:
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL,
REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL.
3. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.
4. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING
SITE SURVEY.
5. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT
MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES
APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE,
ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF
FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT
WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS
RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL
ROAD AND CAN BE REACHED AT (970) 482-1249.
6. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND
POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND CITY SHALL BE NOTIFIED
OF ANY POTENTIAL CONFLICTS.
8. THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING
ELEVATIONS OF ALL EXISTING SEWER MAINS, WATER MAINS, CURBS, GUTTERS AND
OTHER UTILITIES AT THE POINTS OF CONNECTION SHOWN ON THE PLANS, AND AT
ANY UTILITY CROSSINGS PRIOR TO INSTALLING ANY OF THE NEW IMPROVEMENTS.
IF A CONFLICT EXISTS AND/OR A DESIGN MODIFICATION IS REQUIRED, THE
CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN.
Northern Engineering Services, Inc.
NE Project No. 1284-001
Date: July 7, 2016
EXISTING SANITARY SEWER SS
EXISTING WATER W
EXISTING FENCE X
EXISTING WATER METER
EXISTING FIRE HYDRANT
EXISTING ELECTRIC VAULT
PROPERTY BOUNDARY
EXISTING RIGHT-OF-WAY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
5015
5013
VAULT
ELEC
H
Y
D
CONTROL
IRR
H2O
G
EXISTING TREES (TO BE REMOVED)
Earth Engineering Consultants, LLC.
"GEOTECHNICAL SUBSURFACE EXPLORATION REPORT PROPOSED VILLAGE
COOPERATIVE OF FORT COLLINS HORSETOOTH AND STANFORD ROADS"
EEC Project No. 1162088
Date: October 21, 2016
KEYMAP
EC1 EC2
W
W
W
G
G
G
G
G
G
G
G
G
G
G G
G
G
G
G
G
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO FO
FO
FO
FO
FO
FO
W W
STRACHAN 1ST
OWNER: ASPEN LEAF SPE LLC
N:113449.14
E:196923.80
FND #4 REBAR W/
WPC ILLEGIBLE
STRACHAN 3RD
OWNER: ARENA I LLC AND ARENA II LLC
HORSETOOTH ROAD
RIGHT OF WAY VARIES
107.5' TO 108.5'
STANFORD ROAD
78' RIGHT OF WAY
STRACHAN 3RD
OWNER: PETERSON-MOORE LLP
GREENLEE INVESTMENTS LLLP
PRIVATE DRIVE
N:113423.03
E:196654.22
FND #4 REBAR
W/ WPC ILLEGIBLE
N:113529.92
E:196713.26
FND #4 REBAR
W/ WPC ILLEGIBLE
N:113239.19
E:196590.45
FND #4 REBAR
NO CAP 5' EX. ACCESS EASEMENT
TO BE VACATED
20' EX. SANITARY
SEWER EASEMENT
EX. DRAINAGE AND
STORM SEWER
EASEMENT TO BE VACATED
9' EX. UTILITY AND
ACCESS EASEMENT
TO BE VACATED
9' EX. UTILITY AND
ACCESS EASEMENT
20' EX. CITY OF FORT
COLLINS UTILITY EASEMENT
TO BE VACATED
5' EX. DRAINAGE EASEMENT
TO BE VACATED
30' EX. EMERGENCY
ACCESS EASEMENT
TO BE VACATED
30' EX. EMERGENCY ACCESS
EASEMENT
TO BE VACATED
EX. DRAINAGE
EASEMENT
TO BE VACATED
EX. WATER AND
UTILITY EASEMENT
TO BE VACATED
EX. WATER AND
UTILITY EASEMENT
TO BE VACATED
EX. SIGHT DISTANCE
EASEMENT
58.5' HALF RIGHT OF WAY
SAWCUT AND REMOVE
32 LF CURB AND GUTTER
SAWCUT AND REMOVE
67 LF CURB AND GUTTER
REMOVE PAVEMENT
REMOVE PAVEMENT STRIPING
STRIPING
SAWCUT EDGE OF
ASPHALT 1' WIDE
AND REMOVE EXISTING
ASPHALT
RELOCATE EXISTING
FC BIKEWAYS SIGN
EXISTING STORM JUNCTION
STRUCTURE TO BE
RELOCATED, RECONSTRUCTED OR
LEFT IN PLACE.
DEMOLISH EXISTING
INLET
DEMOLISH EXISTING
INLET
RELOCATE EXISTING
TELECOM BOX
RELOCATE EXISTING
ELECTRIC VAULTS
SAW CUT AND PATCH ASPHALT
±151 SQ. YD.
EX. 8" SANITARY SEWER
EX. 12" WATERMAIN
EC1
AND DEMOLITION PLAN
EXISTING CONDITIONS S. Thomas
S. Thomas
1"=20'
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
Call before you dig.
R
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
3
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
MATCHLINE-SEE SHEET EC2
No. Revisions:
By: Date:
REVIEWED BY:
N. HAWS
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
10/25/16
PROJECT:
1284-001
Sheet
Of 15
VILLAGE COOPERATIVE OF FORT COLLINS
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
10/25/16
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
E N G I N E E R I N G
N O R T H E RN
PHONE: 970.221.4158
www.northernengineering.com
EXISTING ELECTRIC E
LEGEND:
G
T
EXISTING STORM SEWER
ST
EXISTING TELEPHONE
EXISTING GAS
EXISTING IRRIGATION BOX
EXISTING GAS METER
EXISTING TELEPHONE PEDESTAL
EXISTING TREES (TO REMAIN)
FIELD SURVEY BY:
SUBSURFACE EXPLORATION BY:
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL,
REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL.
3. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.
4. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING
SITE SURVEY.
5. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT
MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES
APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE,
ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF
FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT
WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS
RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL
ROAD AND CAN BE REACHED AT (970) 482-1249.
6. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND
POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND CITY SHALL BE NOTIFIED
OF ANY POTENTIAL CONFLICTS.
8. THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING
ELEVATIONS OF ALL EXISTING SEWER MAINS, WATER MAINS, CURBS, GUTTERS AND
OTHER UTILITIES AT THE POINTS OF CONNECTION SHOWN ON THE PLANS, AND AT
ANY UTILITY CROSSINGS PRIOR TO INSTALLING ANY OF THE NEW IMPROVEMENTS.
IF A CONFLICT EXISTS AND/OR A DESIGN MODIFICATION IS REQUIRED, THE
CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN.
Northern Engineering Services, Inc.
NE Project No. 1284-001
Date: July 7, 2016
EXISTING SANITARY SEWER SS
EXISTING WATER W
EXISTING FENCE X
EXISTING WATER METER
EXISTING FIRE HYDRANT
EXISTING ELECTRIC VAULT
PROPERTY BOUNDARY
EXISTING RIGHT-OF-WAY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
5015
5013
VAULT
ELEC
H
Y
D
CONTROL
IRR
H2O
G
EXISTING TREES (TO BE REMOVED)
Earth Engineering Consultants, LLC.
"GEOTECHNICAL SUBSURFACE EXPLORATION REPORT PROPOSED VILLAGE
COOPERATIVE OF FORT COLLINS HORSETOOTH AND STANFORD ROADS"
EEC Project No. 1162088
Date: October 21, 2016
KEYMAP
EC1 EC2
COLORADO
Know what's below.
Call before you dig.
R
A. GENERAL NOTES
1. All materials, workmanship, and construction of ppublic improvements shall meet or exceed the standards and specifications set forth in the
Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and
the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the
City of Fort Collins.
2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise.
3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins
Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to
commencement of any work shown in these plans.
4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as
beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort
Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by
law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all
liabilities, claims, and demands which may arise from any errors and omissions contained in these plans.
5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and
specifications current at the date of approval of the plans by the City of Fort Collins Engineer.
6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the
responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing
new construction. The Developer shall be responsible for unknown underground utilities.
7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning
excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to
be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading.
It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these
plans.
8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for
any utility crossings required.
9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the
engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction.
10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is
accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance,
all parties affected by any disruption of any utility service as well as the utility companies.
11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility
provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility
provider, a pre-construction meeting may be required prior to commencement of any work.
12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and
sanitary sewer should be constructed prior to installation of the water lines and dry utilities.
13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the
Water Utility.
14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is
discharged into a storm sewer, channel, irrigation ditch or any waters of the United States.
15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department
of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan.
16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of
onsite drainage facilities shall be the responsibility of the property owner(s).
17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be
submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at
least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be
submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed
prior to certification per the Development Agreement.
18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater
seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as
a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development.
19. All recommendations of the Preliminary Drainage Report for Village Cooperative of Fort Collins dated October 25th, 2016 by Northern
Engineering Services, Inc., shall be followed and implemented.
20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall
be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping.
21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and
debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.)
or as approved by the the City of Fort Collins street inspector.
22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction
Permit is obtained, if applicable.
23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction.
The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control
Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all
public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the
Developer may commence work in the Engineer's absence. However, the City of Fort Collins reserves the right not to accept the
improvement if subsequent testing reveals an improper installation.
24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench
work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not
correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement
section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final
soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a
minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur
until the City of Fort Collins Engineer approves the final report.
25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter
flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must
certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be
noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets.
26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction.
For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be
stubbed to the property lines and marked so as to reduce the excavation necessary for building connections.
27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional
criteria for roads within these districts.
28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as
established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval.
29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any
tree removal requiring a permit.
30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and
security. Refer to OSHA Publication 2226, Excavating and Trenching.
31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The
the City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way.
The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities.
32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins
Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor
moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed.
33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the
Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing
traffic access to and from the Development.
34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site
construction activities on Sundays or holidays, unless there is prior written approval by Larimer County.
35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on
these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise.
36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer
for clarification, and annotate the dimension on the as-built record drawings.
37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and
specifications, and a copy of any permits and extension agreements needed for the job.
38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or
specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately.
39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available
to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort
Collins Engineer.
40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as
well as the basis of bearings. The information shall be as follows:
PROJECT DATUM: NAVD 88
BENCHMARK #1:
CITY OF FORT COLLINS BENCHMARK 29-92: APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT RD. AND SHIELDS ST., ON
THE NORTH END OF THE WEST BRIDGE PARAPET WALL.
ELEVATION: 5025.67
BENCHMARK #2:
CITY OF FORT COLLINS BENCHMARK 28-92: SOUTHWEST CORNER OF WEST PROSPECT RD. AND CENTER AVE., ON A
WATER VALVE PIT.
ELEVATION: 5010.65
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED
NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29
UNADJUSTED = NAVD88 - 3.17.
BASIS OF BEARINGS
THE BASIS OF BEARINGS IS THE SOUTH LINE OF THE SOUTHWEST QUARTER OF SECTION 14, TOWNSHIP 7 NORTH, RANGE
69 WEST OF THE 6TH P.M. AS BEARING SOUTH 89°22'14" EAST
41. All stationing is based on centerline of roadways unless otherwise noted.
42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters,
landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored
in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements
and/or prior to the issuance of the first Certificate of Occupancy.
43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The
existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be
done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing
surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the
entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the
Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made.
44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before
construction, or to the grades and condition as required by these plans.
45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections.
46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and
workmanship defects for a minimum period of two years from the date of acceptance.
47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage
structures and pipes, for the following private streets: N.A.
48. Approved Variances are listed as follows: N.A.
CONSTRUCTION NOTES
A. Grading and Erosion Control Notes
1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site.
2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans.
3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc).
All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the
approved project schedule, construction plans, and erosion control report.
4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the
property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining
all erosion control facilities shown herein.
5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be
limited to the area(s) required for immediate construction operations, and for the shortest practical period of time.
6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened
condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils
in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required
temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County.
7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall:
a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as
necessary in order to ensure the continued performance of their intended function.
b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control
inspector.
c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector.
8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment
and debris from all drainage infrastructure and other public facilities.
9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public
rights of way, and make sure streets and walkways are cleaned at the end of each working day.
10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not
to cause their release into any waters of the United States.
11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening,
watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched.
12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project
and before turning the maintenance over to the City/County or Homeowners Association (HOA).
13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any
pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete
truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are
necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and
federal regulations.
14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout
material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the
concrete washout material will be removed and properly disposed of prior to the area being restored.
15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement
whatever measures are determined necessary, as directed by the City.
B. Street Improvement Notes
1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed
here.
2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for
approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt).
The job mix shall be submitted for approval prior to placement of any asphalt.
3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing
edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean
construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins.
4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the
subgrade has been inspected and approved by the City of Fort Collins Engineer.
5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting
rings are not allowed.
6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The
existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in
conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The
determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with
adjacent landowners such that future projects do not cut the new asphalt overlay work.
7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement)
and as per the Right-of-Way Work Permit traffic control plan.
8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of
asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain
properly.
9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a
full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will
be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than
50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall
not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as
determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface.
The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence
of an Inspector.
C. Traffic Signing and Pavement Marking Construction Notes
1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking
Construction Notes listed here.
2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic.
3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD.
4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads.
5. All lane lines for concrete pavement should be epoxy paint.
6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and
placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of
striping and symbols.
7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards.
8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction.
9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings.
10. All sign posts shall utilize break-away assemblies and fasteners per the Standards.
11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies
identified during the field inspection must be corrected before the 2-year warranty period will begin.
12. The Developer installing signs shall be responsible for locating and protecting all underground utilities.
13. Special care shall be taken in sign location to ensure an unobstructed view of each sign.
14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of
Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer
determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and
striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings).
15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail.
D. Storm Drainage Notes
1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of
onsite drainage facilities shall be the responsibility of the property owner(s).
2. All recommendations of the Preliminary Drainage Report for Village Cooperative of Fort Collins dated October 25th, 2016 by Northern
Engineering Services, Inc., shall be followed and implemented.
3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by
submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at
least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by
submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed
prior to certification per the Development Agreement.
E. Utility Notes
1. All waterline and sanitary sewer construction shall conform to the Fort Collins Utility standards and specifications current to date of
construction.
2. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the
water utility.
3. Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire.
4. HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and
ASTM. The HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections. Tracer
wire shall be installed with the HDPE service, and shall extend up the curb stop. The curb stop shall be covered with a metal box and tracer
wire test lid per City Water Detail 25.
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
OCTOBER 2016 CONTACT INFORMATION
PROJECT TEAM:
Northern Engineering Services, Inc.
Nick Haws, PE
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
(970) 221-4158
Northern Engineering Services, Inc.
Eric Smith, PLS
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
(970) 221-4158
E N G I N E E R I N G
N O R T H E RN
E N G I N E E R I N G
N O R T H E RN
I hereby affirm that these final
construction plans were prepared
under my direct supervision, in
accordance with all applicable City
of Fort Collins and State of
Colorado standards and statutes,
respectively; and that I am fully
responsible for the accuracy of all
design. revisions, and record
conditions that I have noted on
these plans.
These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility
by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness
of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities
required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort
Collins for additional quantities of items shown that may be required during the construction phase.
DISCLAIMER STATEMENT:
CERTIFICATION STATEMENT:
PROJECT
LOCATION
VICINITY MAP
NORTH 1"=2000'
SITE ENGINEER
SURVEYOR
PROJECT DATUM: NAVD 88
BENCHMARK #1:
CITY OF FORT COLLINS BENCHMARK 7-13: NORTHWEST CORNER OF HORSETOOTH RD. AND
TIMBERLINE RD., ON A CONCRETE TRAFFIC SIGNAL BASE.
ELEVATION: 5005.59
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING
DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION
SHOULD BE USED:
NGVD29 UNADJUSTED = NAVD88 - 3.17.
BASIS OF BEARINGS
THE BASIS OF BEARINGS IS THE SOUTH LINE OF LOT 1 AS BEARING NORTH 89°51'02" WEST.
Northern Engineering Services, Inc
NE Project No. 1284-001
Date: July 7, 2016
ORIGINAL FIELD SURVEY BY:
Earth Engineering Consultants, LLC
EEC Project No. 1162088
Date: October 21, 2016
SUBSURFACE EXPLORATION BY:
PROJECT BENCHMARKS:
SHEET INDEX
COVER SHEET
GENERAL & CONSTRUCTION NOTES
CS1
CS2
EC1-EC2 EXISTING CONDITIONS & DEMOLITION PLAN
UTILITY PLANS FOR
VILLAGE COOPERATIVE OF FORT COLLINS
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
Call before you dig.
R
UTILITY CONTACT LIST: *
UTILITY COMPANY
* This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for
the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for
locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of
Colorado (UNCC) at 811 for additional information.
PHONE NUMBER
GAS----------------- Xcel Energy----------------------------- Stephanie Rich (970) 225-7857
ELECTRIC-------- City of Fort Collins Light & Power-- Luke Unruh (970) 416-2724
CABLE------------- Comcast---------------------------------- Don Kapperman (970) 567-0425
TELECOM.--------CenturyLink------------------------------- William Johnson (970) 377-6401
WATER------------ City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339
WASTEWATER--City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339
LANDSCAPE ARCHITECT STORMWATER- City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339
GEOTECHNICAL ENGINEER
Earth Engineering Consultants, LLC
David A. Richer, PE
4396 Greenfield Drive
Windsor, Colorado 80550
(970) 545-3908
DEVELOPER/APPLICANT
U1-U2 UTILITY PLAN
G1-G2 GRADING PLAN
R3 HORSETOOTH ROAD STRIPING PLAN
LOT 1, BELLAVISTA PDP, LOCATED IN THE SOUTHWEST QUARTER OF SECTION 25,
TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO
Ripley Design Inc.
Cathy Mathis
444 Mountain Avenue
Berthoud, Colorado 80513
(970) 532-5891
DR1 DRAINAGE EXHIBIT
XS1 HORSETOOTH ROAD CROSS SECTIONS
HC1-HC2 HORIZONTAL CONTROL & SIGNAGE PLAN
R1-R2 HORSETOOTH ROAD PLAN & PROFILE
Village Cooperative of Fort Collins
Shane Wright
1400 Corporate Center Curve, Suite 100
Eagan, Minnesota 55121
(651) 760-8306