HomeMy WebLinkAboutLEGACY AUTO - PDP - PDP120001 - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTSITEM NO __________________ MEETING DATE __June 26, 2014____ STAFF __Seth Lorson_____ ADMINISTRATIVE HEARING Planning Services 281 N College Ave – PO Box 580 – Fort Collins, CO 80522-0580 fcgov.com/developmentreview/ 970.221.6750 STAFF REPORT PROJECT: Legacy Auto (1845 N. College Ave.) #PDP120001 APPLICANT/OWNER: Legacy Tractor and Auto Sales 1845 N. College Ave. Fort Collins, CO 80524 PROJECT DESCRIPTION: This project proposes to construct a 6,000 square foot addition to the existing 1,221 square foot Legacy Auto building, construct a 4,800 square foot warehouse, and pave 41 customer parking spaces, 36 display spaces, 38 storage spaces and the accompanying drive aisles. The construction is proposed to be completed in four phases. This project is an expansion of existing vehicle sales facilities for “urban tractors”, ATVs, trailers, personal water/snow crafts, cars, light trucks, and conversion vans, including the sales offices and storage warehouse. Map 1: Legacy Auto Location (1845 N. College Ave.) Legacy Auto, PDP #120001 Administrative Hearing 06-26-2014 Page 2 RECOMMENDATION: Approval EXECUTIVE SUMMARY: The proposed PDP has been reviewed by staff and is in compliance with all applicable Land Use Code (LUC) standards with the exception of two proposed modifications of standard for which staff is recommending approval based on findings that the modifications are not detrimental to the public good, and that: 1) by reason of exceptional physical conditions of the site, and 2) do not diverge from the standards except in a nominal and inconsequential way (Sec. 2.8.2.). COMMENTS: 1. Background The project site is zoned Service Commercial (CS) and the surrounding zoning and land uses are as follows: Direction Zone District Existing Land Uses North Larimer County: Commercial (C) Multi-family (MF-1) Retail (liquor store) Residential (mobile home park) South Service Commercial (CS) Commercial (Lamplighter Hotel) East Community Commercial North College (CCN) Commercial (North College Marketplace) West Service Commercial (CS) Commercial (warehouse) 2. Compliance with Applicable Service Commercial (CS) District Standards [Division 4.22] A. Purpose: The purpose of the Service Commercial District is as follows: The Service Commercial District is intended for high traffic commercial corridors where a range of uses is encouraged to create a transition from commercial operations on a highway, arterial street or rail spur, to less intensive use areas or residential neighborhoods. This designation is only for areas that have been designated under an adopted subarea plan as being appropriate for the C-S District. The proposed project is consistent with the stated purpose of the zone district as the use proposed is an existing use along a high traffic highway and does not directly abut a residential neighborhood. Legacy Auto, PDP #120001 Administrative Hearing 06-26-2014 Page 3 B. Permitted Land Uses: [Section 4.22 (B)] The proposed use of Vehicle Sales is permitted in this zone district provided that it is limited to ten percent of the frontage of both sides of North College Avenue between Vine Drive and the northern City limits. However, the vehicle sales use on the subject property is existing and predates the standard, which was established based on the North College Corridor Plan process. All the existing vehicle sales uses are permitted. C. Land Use Standards: [Section 4.22 (D)] The maximum building height shall be three stories. The proposed one-story buildings have a maximum height of 27 feet 5 ¼ inches. 3. Compliance with Applicable General Development Standards – Article 3 A. Site Planning and Design Standards [Division 3.2] 3.2.1(D)(2) Street Trees: Three street trees exist and the proposed development is providing additional street trees to ensure an average of 30 to 40 foot intervals as required. 3.2.1(E)(2) Landscape Area Treatment: The areas of the site that are not covered by buildings, structures, paving or impervious surface are proposed to be landscape areas that incorporate turf grass, shrubs, and trees as required. 3.2.1(E)(4) Parking Lot Perimeter Landscaping: Trees are provided between all parking lots (and vehicle use areas) and public streets at an average ratio of one per 25 lineal feet, and in the side lot setback at an average ratio of one per 40 lineal feet. 3.2.1(E)(4) Parking Lot Interior Landscaping: Parking lot landscape islands are provided throughout the site greater than six percent of the interior space of the parking lots. The landscape islands are used to buffer the vehicle use area from College Avenue with plantings of shrubs and trees. 3.2.2(K)(2) Nonresidential Parking Requirements: The maximum amount of parking permitted for General Retail (which is the most similar use listed) is four parking spaces per 1,000 square feet. The project is Legacy Auto, PDP #120001 Administrative Hearing 06-26-2014 Page 4 proposing a total of 12,011 square feet of floor area and thus is permitted a maximum of 48 parking spaces ([12,011/1,000]*4). The project proposes to provide 44 parking spaces. All other vehicle use areas, totaling 74 parking spaces, are for storage and display and do not count toward the maximum parking requirement. 3.2.4 Site Lighting: The maximum light level permitted on the site is 10 foot candles and the maximum level shown on the lighting plan is 8.7 foot candles. The site lighting does not spill over the lot lines beyond 20 feet in excess of 0.1 foot candles. B. Natural Habitats and Features [Division 3.4.1] The Legacy Auto site is south of the Larimer and Weld Canal; the standard buffer for an irrigation ditch serving as a wildlife corridor is 50’ (Section 3.4.1(E)(1). The existing site’s habitat value is very limited due to no vertical diversity exists as only non-native grasses are found within the 50’ buffer zone. To meet the standards associated with Section 3.4.1, the project has proposed to apply the quantitative (50’ buffer) and qualitative standards contained in Section 3.4.1(E) of the Land Use Code: The proposed buffer is 50’ in width, meeting the quantitative standard. The project meets the qualitative performance standards in Section 3.4.1 by incorporating the following elements into the design: • No fencing is proposed between the ditch and the development, which will allow for wildlife movement across the site (Section 3.4.1(E)(1)(b)). • The project enhances the vegetation by providing additional trees, shrubs, and native grasses to enhance the value of the ditch as a wildlife corridor. A mix of deciduous and evergreen species will provide cover for wildlife in all seasons (Section 3.4.1(E)(1)(g)). • There is no light spillover into the buffer zone to minimize impacts to the area as a wildlife corridor (Section 3.4.1(E)(1)(e)). C. Building Standards [Division 3.5] 3.5.1 Building and Project Compatibility The proposed development is compatible with the existing surrounding development in terms of height, bulk, mass, and scale. The buildings are Legacy Auto, PDP #120001 Administrative Hearing 06-26-2014 Page 5 proposed at one-story and the existing buildings across the street (Chase Bank) are one story and the motel (America’s Best Value Inn, directly abutting to the south) has one-and two-story buildings. 3.5.3 Mixed-Use, Institutional, and Commercial Buildings Relationship of Buildings to Streets, Walkways, and Parking. [Section 3.5.3(C)] The main entrances of the building face onto a sidewalk with crosswalks across the drive aisle attaching to the College Avenue sidewalk. An existing canopy from a previous gas station, with a pedestrian crosswalk underneath, will remain as an architectural feature that carries the existing and proposed buildings to the College Avenue frontage. However, the applicant has requested an exception to the build-to line standard requiring that the building be located no more than 15 feet from the College Avenue ROW. And, the applicant has requested a Modification of Standard to permit a vehicular use area between the building and the street (discussed below). An exception to the 15 foot build-to line standard may be granted “if the building abuts a four-lane or six-lane arterial street, and the Director has determined that an alternative to the street sidewalk better serves the purpose of connecting commercial destinations due to one or more of the following conditions:” The proposed building addition abuts College Avenue, a 4-lane arterial in this location, and the existing building and the buildings to the south have established a pattern of development that has similar setbacks as the proposed addition. Setbacks from ROW: Existing Building: 64’ 3” Proposed Addition: 60’ 7” America’s Best Value Inn: 51’ 2” Loaf-n-Jug: 66’ 4” Additionally, the proposed site plan provides walkways connecting to the College Avenue sidewalk, extensive landscaping and pedestrian benches all meant to engage the public realm and mitigate the impact of the additional setback distance. Variation in Massing. [Section 3.5.3 (D)] and Character and Image. [Section 3.5.2 (E)] The proposed buildings are simple in form but provide variation with a variety of materials and architectural features. The easternmost building, an existing building and a proposed addition, has a pronounced entrance and canopied abutting walkway. Along its west elevation, gable dormer windows break up the Legacy Auto, PDP #120001 Administrative Hearing 06-26-2014 Page 6 massing. The westernmost building (warehouse) also has a central pronounced entrance and four other double-door entrances along its south side. The north side has garage doors that are separated with brick pilasters. Both buildings feature cultured stone wainscot with stone sills and primarily consist of wood siding. 4. Modification of Standards [Division 2.8] A. Relationship of Buildings to Streets, Walkways and Parking. [3.5.3(C)(1)&(2)] The applicant is requesting a modification to the standard requiring that developments have “no vehicle use area between building faces and the street” as a function of the 15 foot build-to line requirement. The proposed vehicle use area precludes compliance with the requirement to orient to a Connecting Walkway which is defined as a walkway that directly connects a main entrance of a building to the street sidewalk without requiring pedestrians to walk across parking lots or driveways. The project proposes nine display spaces for their inventory directly between the street and the proposed building, and an additional 18 display spaces along the College Avenue frontage. The applicant requests that the Hearing Officer find that the requested modification be granted on the grounds that it is not detrimental to the public good and by reason of exceptional physical conditions or other extraordinary and exceptional situations, unique to such property. The College Avenue streetscape was improved and installed by the City of Fort Collins as a capital project which created an access to this site directly adjacent to the proposed addition. Said access would be entirely blocked if this addition were to meet the required build-to line standard. Additionally, site circulation around the back of the existing building is difficult due to a significant grade drop directly to the west. Please see attached the applicant’s request for a modification of standard and existing condition images. B. Industrial uses located at least 200 feet from North College Avenue [4.22(B)(d)(1)&(5)] The applicant is requesting a modification to the standard requiring that warehouses and wholesale distribution facilities are setback at least 200 feet from North College Avenue. Legacy Auto, PDP #120001 Administrative Hearing 06-26-2014 Page 7 The project proposes a 4,800 square foot warehouse and distribution facility located on the western portion of the lot, 182 feet setback from North College Avenue. The applicant asks that the Hearing Officer find that the requested modification be granted on the grounds that it is not detrimental to the public good and that the modification does not diverge from the standard except in a nominal, inconsequential way when considered from the perspective of the entire development plan. The proposed warehouse and distribution building is sited behind the existing building, the proposed 6,000 square foot addition, and a 6-foot-high fence used to screen vehicle storage. The 18 foot difference between the requirement and the proposal represents the exact distance that was dedicated as ROW for the North College Avenue streetscape improvements. 5. Findings of Fact/Conclusion In evaluating Legacy Auto (1845 N. College Ave.), #PDP120001, Staff makes the following findings of fact: A. The request for a modification of standard to permit a vehicle use area between the building face and the street (3.5.3(C)(2)) is not detrimental to the public good and by reason of exceptional physical conditions or other extraordinary and exceptional situations, unique to such property because the North College Avenue streetscape improvements created a curb cut access in the logical area to site an addition to the existing building that would comply with said standard. B. The request for a modification of standard to reduce the required setback for a warehouse and wholesale distribution building (4.22(B)(d)(1)&(5)) is not detrimental to the public good and does not diverge from the standard except in a nominal, inconsequential way when considered from the perspective of the entire development plan. This is because the proposed setback of 182 feet is hidden behind the principal addition and screening and represents a divergence of 9% from the required setback. C. The PDP contains permitted uses and complies with the applicable land development standards of the Service Commercial District in accordance with Article 4 of the Land Use Code with the exception of the requested modification of standards. D. The PDP complies with the applicable General Development Standards of Article 3 of the Land Use Code with the exception of the requested modification of standards. Legacy Auto, PDP #120001 Administrative Hearing 06-26-2014 Page 8 E. The PDP complies with the applicable procedural and administrative requirements of Article 2 of the Land Use Code. RECOMMENDATION: Staff recommends approval of Legacy Auto (1845 N. College Ave.), #PDP120001 ATTACHMENTS: 1 – PDP Plan Set 2 – Modification Requests 3 – Applicant Narrative 4 – Existing Site Images