Loading...
HomeMy WebLinkAbout2133 S. TIMBERLINE RD., OFFICE & RESTAURANT - FDP - FDP160015 - CORRESPONDENCE -Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov.com/developmentreview April 27, 2016 Keith Meyer 1315 OAKRIDGE DR SUITE 120 Fort Collins, CO 80525 RE: 2133 S Timberline Rd.-Office and Restaurant, FDP160015, Round Number 1 Comment Summary: Department: Engineering Development Review Contact: Marc Ragasa, 970.221.6603, mragasa@fcgov.com Topic: General 04/26/2016: Remove note 47 from the Utility Plan, General Notes. Comment Number: 1 Comment Originated: 04/26/2016 04/26/2016: Note 19 in the General Notes needs to be updated to include the correct erosion control study date. Comment Number: 2 Comment Originated: 04/26/2016 04/26/2016: Label the Slope and Drainage Easement to be vacated on the Existing conditions sheet. The slope and drainage easement can then be removed on the following sheets. Comment Number: 3 Comment Originated: 04/26/2016 04/26/2016: The existing islands on Lot 2, timberline Center, Second Filing can be removed on sheets following the Existing Conditions sheet. Show the islands in the ultimate configuration. Comment Number: 4 Comment Originated: 04/26/2016 04/26/2016: Please work with PFA fore requirements regarding the Fire Lane signage and easements. Based on the plat, the Emergency Access Easements extend into parking stall areas. Typically, no parking is allowed within Emergency Access Easements. Please see if the plat needs to be refined. Comment Number: 5 Comment Originated: 04/26/2016 Department: Light And Power Contact: Todd Vedder, 970-224-6152, tvedder@fcgov.com Topic: General Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Seth Lorson, at 970-224-6189 or slorson@fcgov.com. Page 1 of 3 04/22/2016: A survey will need to be done to ensure the transformer located at 2101 S. Timberline Rd is in a utility easement. Comment Number: 1 Comment Originated: 04/22/2016 04/22/2016: A C-1 form and one-line diagram will need to be submitted for transformer sizing and billing needs. A link to a C-1 form is below. http://www.fcgov.com/utilities/business/builders-and-developers/development-forms -guidelines-regulations Comment Number: 2 Comment Originated: 04/22/2016 04/22/2016: Please provide finalized AutoCAD drawings for the site and utility plans to Todd Vedder, tvedder@fcgov.com Comment Number: 3 Comment Originated: 04/22/2016 Department: Outside Agencies Contact: Seth Lorson, 970-224-6189, slorson@fcgov.com Topic: General 04/06/2016: Xcel Energy Gas main extension required. Comment Number: 1 Comment Originated: 04/06/2016 Department: Stormwater Engineering Contact: Wes Lamarque, 970-416-2418, wlamarque@fcgov.com Topic: General 04/27/2016: LID sizing calculations are required for the PLDs and the bio-swale. Comment Number: 2 Comment Originated: 04/27/2016 04/27/2016: Clarification is needed for the PLD near the northwest corner of the building. It is unclear how drainage will enter the pond rather than flow north along the curb & gutter. Also, an outlet structure is needed to ensure the 1-foot maximum ponding depth with an overflow for larger storm events. Comment Number: 3 Comment Originated: 04/27/2016 04/27/2016: The grading for the PLDs at the back of the building need to be shown on the plans. It is unclear how the LID feature will function in this location. Comment Number: 4 Comment Originated: 04/27/2016 04/27/2016: The details for the rain garden and the bio-swale need some revisions. Please see redlines. Comment Number: 5 Comment Originated: 04/27/2016 Department: Technical Services Contact: Jeff County, 970-221-6588, jcounty@fcgov.com Topic: Building Elevations 04/26/2016: No comments. Comment Number: 6 Comment Originated: 04/26/2016 Topic: Construction Drawings 04/26/2016: All plan sheets must be 24"x36". Comment Number: 8 Comment Originated: 04/26/2016 Page 2 of 3 04/26/2016: Please tie the coordinate values shown for utilities to the project boundary. We would prefer that this be done by adding property corner values to each sheet, or showing the property corner values on the horizontal control plans and adding a note to each sheet with coordinate values. Comment Number: 9 Comment Originated: 04/26/2016 Topic: Landscape Plans 04/25/2016: Some of the easement descriptions shown are incorrect. If they are going to stay on the plan, they should match what is shown on the Subdivision Plat. See redlines. Comment Number: 5 Comment Originated: 04/25/2016 Topic: Lighting Plan 04/26/2016: No comments. Comment Number: 7 Comment Originated: 04/26/2016 Topic: Plat 04/25/2016: The Basis Of Bearings statement does not match. See redlines. Comment Number: 1 Comment Originated: 04/25/2016 04/25/2016: Please add dedication information for all street rights of way. See redlines. Comment Number: 2 Comment Originated: 04/25/2016 Topic: Site Plan 04/25/2016: Some of the easement descriptions shown are incorrect. If they are going to stay on the plan, they should match what is shown on the Subdivision Plat. See redlines. Comment Number: 3 Comment Originated: 04/25/2016 04/25/2016: There are line over text issues. See redlines. Comment Number: 4 Comment Originated: 04/25/2016 Department: Water-Wastewater Engineering Contact: Wes Lamarque, 970-416-2418, wlamarque@fcgov.com Topic: General 04/27/2016: No comments. Comment Number: 1 Comment Originated: 04/27/2016 Department: Zoning Contact: Noah Beals, 970-416-2313, nbeals@fcgov.com Topic: General 04/26/2016: The minor amendment needs to be finalized. Please contact for more info. Comment Number: 1 Comment Originated: 04/26/2016 Page 3 of 3