RE: 2133 S Timberline Rd.-Office and Restaurant, FDP160015, Round Number 1
Comment Summary:
Department: Engineering Development Review
Contact: Marc Ragasa, 970.221.6603, mragasa@fcgov.com
Topic: General
04/26/2016: Remove note 47 from the Utility Plan, General Notes.
Comment Number: 1 Comment Originated: 04/26/2016
04/26/2016: Note 19 in the General Notes needs to be updated to include the
correct erosion control study date.
Comment Number: 2 Comment Originated: 04/26/2016
04/26/2016: Label the Slope and Drainage Easement to be vacated on the Existing
conditions sheet. The slope and drainage easement can then be removed on the
following sheets.
Comment Number: 3 Comment Originated: 04/26/2016
04/26/2016: The existing islands on Lot 2, timberline Center, Second Filing can be
removed on sheets following the Existing Conditions sheet. Show the islands in the
ultimate configuration.
Comment Number: 4 Comment Originated: 04/26/2016
04/26/2016: Please work with PFA fore requirements regarding the Fire Lane
signage and easements. Based on the plat, the Emergency Access Easements
extend into parking stall areas. Typically, no parking is allowed within Emergency
Access Easements. Please see if the plat needs to be refined.
Comment Number: 5 Comment Originated: 04/26/2016
Department: Light And Power
Contact: Todd Vedder, 970-224-6152, tvedder@fcgov.com
Topic: General
Please see the following summary of comments from City staff and outside reviewing agencies for
your submittal of the above referenced project. If you have questions about any comments, you may
contact the individual commenter or direct your questions through the Project Planner, Seth Lorson, at
970-224-6189 or slorson@fcgov.com.
Page 1 of 3
04/22/2016: A survey will need to be done to ensure the transformer located at 2101
S. Timberline Rd is in a utility easement.
Comment Number: 1 Comment Originated: 04/22/2016
04/22/2016: A C-1 form and one-line diagram will need to be submitted for
transformer sizing and billing needs. A link to a C-1 form is below.
http://www.fcgov.com/utilities/business/builders-and-developers/development-forms
-guidelines-regulations
Comment Number: 2 Comment Originated: 04/22/2016
04/22/2016: Please provide finalized AutoCAD drawings for the site and utility plans
to Todd Vedder, tvedder@fcgov.com
Comment Number: 3 Comment Originated: 04/22/2016
Department: Outside Agencies
Contact: Seth Lorson, 970-224-6189, slorson@fcgov.com
Topic: General
04/06/2016: Xcel Energy
Gas main extension required.
Comment Number: 1 Comment Originated: 04/06/2016
Department: Stormwater Engineering
Contact: Wes Lamarque, 970-416-2418, wlamarque@fcgov.com
Topic: General
04/27/2016: LID sizing calculations are required for the PLDs and the bio-swale.
Comment Number: 2 Comment Originated: 04/27/2016
04/27/2016: Clarification is needed for the PLD near the northwest corner of the
building. It is unclear how drainage will enter the pond rather than flow north along
the curb & gutter.
Also, an outlet structure is needed to ensure the 1-foot maximum ponding depth with
an overflow for larger storm events.
Comment Number: 3 Comment Originated: 04/27/2016
04/27/2016: The grading for the PLDs at the back of the building need to be shown
on the plans. It is unclear how the LID feature will function in this location.
Comment Number: 4 Comment Originated: 04/27/2016
04/27/2016: The details for the rain garden and the bio-swale need some revisions.
Please see redlines.
Comment Number: 5 Comment Originated: 04/27/2016
Department: Technical Services
Contact: Jeff County, 970-221-6588, jcounty@fcgov.com
Topic: Building Elevations
04/26/2016: No comments.
Comment Number: 6 Comment Originated: 04/26/2016
Topic: Construction Drawings
04/26/2016: All plan sheets must be 24"x36".
Comment Number: 8 Comment Originated: 04/26/2016
Page 2 of 3
04/26/2016: Please tie the coordinate values shown for utilities to the project
boundary. We would prefer that this be done by adding property corner values to
each sheet, or showing the property corner values on the horizontal control plans
and adding a note to each sheet with coordinate values.
Comment Number: 9 Comment Originated: 04/26/2016
Topic: Landscape Plans
04/25/2016: Some of the easement descriptions shown are incorrect. If they are
going to stay on the plan, they should match what is shown on the Subdivision Plat.
See redlines.
Comment Number: 5 Comment Originated: 04/25/2016
Topic: Lighting Plan
04/26/2016: No comments.
Comment Number: 7 Comment Originated: 04/26/2016
Topic: Plat
04/25/2016: The Basis Of Bearings statement does not match. See redlines.
Comment Number: 1 Comment Originated: 04/25/2016
04/25/2016: Please add dedication information for all street rights of way. See
redlines.
Comment Number: 2 Comment Originated: 04/25/2016
Topic: Site Plan
04/25/2016: Some of the easement descriptions shown are incorrect. If they are
going to stay on the plan, they should match what is shown on the Subdivision Plat.
See redlines.
Comment Number: 3 Comment Originated: 04/25/2016
04/25/2016: There are line over text issues. See redlines.
Comment Number: 4 Comment Originated: 04/25/2016
Department: Water-Wastewater Engineering
Contact: Wes Lamarque, 970-416-2418, wlamarque@fcgov.com
Topic: General
04/27/2016: No comments.
Comment Number: 1 Comment Originated: 04/27/2016
Department: Zoning
Contact: Noah Beals, 970-416-2313, nbeals@fcgov.com
Topic: General
04/26/2016: The minor amendment needs to be finalized. Please contact for more
info.
Comment Number: 1 Comment Originated: 04/26/2016