HomeMy WebLinkAbout2590 MIDPOINT DRIVE - FDP - FDP160031 - CORRESPONDENCE - RESPONSE TO STAFF REVIEW COMMENTSCommunity Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov.com/developmentreview September 02, 2016 Cathy Mathis TB GROUP 444 MOUNTAIN AVE Berthoud, CO 80513 RE: 2590 Midpoint Drive, FDP160031, Round Number 1 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Meaghan Overton, at 970-416-2283 or moverton@fcgov.com. Comment Summary: Department: Engineering Development Review Contact: Katie Andrews, 970-221-6501, kandrews@fcgov.com Topic: General Comment Number: 1 Comment Originated: 08/26/2016 08/26/2016: Driveway should be concrete to the back of walk per included LCUASS detail 707.1. Please reflect this in the plans and remove detail 710. RESPONSE: Detail 710 has been removed and Concrete drive has been revised to correlate with detail 707.1. Comment Number: 2 Comment Originated: 08/30/2016 08/30/2016: Please move the City signature block to the lower right-hand corner of each sheet and include it on every sheet. RESPONSE: City signature block has been moved to the bottom right hand corner and added to each sheet in the plan set. Comment Number: 3 Comment Originated: 08/30/2016 08/30/2016: Title "Utility Plans for" should be followed by the project name "2590 Midpoint Drive." RESPONSE: Clarification was given to us that Jeff prefers the Title of the project to be “Lot 18” instead of “2590 Midpoint.” Title now reads Utility Plans for Lot 18, 2590 Midpoint Drive, Prospect Industrial Park. Department: PFA Contact: Jim Lynxwiler, 970-416-2869, jlynxwiler@poudre-fire.org Topic: General Comment Number: 1 Comment Originated: 09/01/2016 09/01/2016: FIRE CONTAINMENT The proposed building exceeds 5,000 square feet and shall be sprinklered or fire contained. As the current plan is to provide fire containment, the plan for containment construction shall be reviewed and approved by the Poudre Fire Authority prior to installation. RESPONSE: Building will be provided with a sprinkler connection. Comment Number: 2 Comment Originated: 09/01/2016 09/01/2016: PRIOR COMMENT FROM PDP Perimeter fire access is required to within 150' of all exterior portions of the building. Since the building will not be provided a fire sprinkler system, the structure reverts to 60' out of access and the limits of the fire lane will need to be adjusted to include a fire lane on the north side of the building with an approved turnaround. RESPONSE: Building will be provided with a sprinkler connection See earlier comment from PDP regarding perimeter access: Prior comment from 03/31/2016: FIRE LANE - Emergency Access Easement details will be provided by time of FDP. The fine lane will need to extend onto the property, along the north side of the building, to 150' in length and no turnaround will be required. The building will be approximately 60' out of access as defined by IFC 503.1.1, however as the building will be provided with an automatic fire sprinkler system, the out of access condition is allowable. Code language provided below. RESPONSE: Building will be provided with a sprinkler connection; no further improvements should have to be made to the site plan. With coordination from the Poudre Fire Authority, a fire access lane has been added to the Utility Plan C-3.0. > IFC 503.1.1: Approved fire Lanes shall be provided for every facility, building or portion of a building hereafter constructed or moved into or within the jurisdiction. The fire apparatus access road shall comply with the requirements of this section and shall extend to within 150 feet of all portions of the facility and all portions of the exterior walls of the first story of the building as measured by an approved route around the exterior of the building or facility. When any portion of the facility or any portion of an exterior wall of the first story of the building is located more than 150 feet from fire apparatus access, the fire code official is authorized to increase the dimension if the building is equipped throughout with an approved, automatic fire-sprinkler system. RESPONSE: A 24’ fire access easement has been added to the plan set after discussion with Poudre Fire Authority. With the building sprinklered and access easement shown, we are meeting the requirements for quality fire protection. Comment Number: 3 Comment Originated: 09/01/2016 09/01/2016: SECURITY GATES The gating plan across a fire lane will need to be reviewed and approved. Code language provided below. > IFC 503.6: The installation of security gates across a fire apparatus access road shall be approved by the fire chief. Where security gates are installed, they shall have an approved means of emergency operation. The security gates and the emergency operation shall be maintained operational at all times. > IFC D103.5: Gates securing fire apparatus access roads shall comply with all of the following criteria: 1. The minimum gate width for vehicle access shall be 20 feet. 2. Gates shall be of the swinging or sliding type. 3. Construction of gates shall be of materials that allow manual operation by one person. : 4. Gate components shall be maintained in an operative condition at all times and replaced or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with an unapproved padlock, or chain and padlock, unless they are capable of being opened by means of forcible entry tools or when a key box containing the key(s) to the lock is installed at the gate location. 7. Gate design and locking device specifications shall be submitted for approval by the fire code official prior to installation. 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates intended for automatic operation shall be designed, constructed and installed to comply with the requirements of ASTM F 2200. RESPONSE: No gate will be installed across the approved fire lane. Department: Planning Services Contact: Meaghan Overton, 970-416-2283, moverton@fcgov.com Topic: Building Elevations Comment Number: 4 Comment Originated: 08/29/2016 08/29/2016: All TBD for colors should be edited with colors when chosen. Colors should be neutral. RESPONSE: Colors have been updated, see elevations Comment Number: 5 Comment Originated: 08/29/2016 08/29/2016: Detail sheets indicated in the Keynote Text: A7.1 (C5) and xx/As.x (C11) will need to be provided or these references should be removed. RESPONSE: Notes have been updated Topic: General Comment Number: 7 Comment Originated: 08/29/2016 08/29/2016: Common questions we receive at this point in the process: When can I get my building permit? and, When can I submit for building permit? Please be aware of the following steps and policies regarding the finalization of your documents prior to full building permit review: -- Development Agreement, Contact: Katie Andrews at (970) 221-6501 to coordinate. -- Development Permit Coordination: DCP or excavation permit, utility coordination meeting, etc. Also finalize the coordination of any offsite easements prior to recording of mylars. Contact: Katie Andrews at (970) 221-6501 to coordinate. --Signing and Recording: Three documents are signed. This includes the planning set, utility plans and plat. (No new plat for this project). The planning set is held until the utility plan mylars are signed, then the planning mylars are signed last. It may take several days for staff to gather all of the signatures on the utility plans, and then the planning mylars are signed shortly thereafter. --Land Records Established: Technical Services and GIS will then work on establishing your land records in order to trigger your full building permit review (see below).  Mylars must be recorded and indexed first  GIS steps: plat and easement information entered into CAD,  assignment of addresses (if not assigned),  import land records data into City database,  data is reviewed for accuracy and made available for building permit review. RESPONSE: Acknowledged. --Building Permit Review: Once GIS has completed the land records process above, you are ready to submit for full BP review. Contact, Building Services at 416-2740 if you have questions on the submittal items. The DCP (Development Construction Permit) process can overlap with the above preparation and review of the building permit. Comment Number: 8 Comment Originated: 09/02/2016 09/02/2016: The project title should be "Lot 18, Prospect Industrial Park" on all sheets. The address (2590 Midpoint Drive) should be below the Lot 18 title if the address is included on submittal documents. RESPONSE: The title has been changed on all sheets, Topic: Site Plan Comment Number: 1 Comment Originated: 08/29/2016 08/29/2016: The detention basin outline is missing in the basin along the Midpoint Drive frontage of the building. Please add this back on to the site plan. RESPONSE: The detention pond has been added back. Comment Number: 2 Comment Originated: 08/29/2016 08/29/2016: Please correct square footage of the office space in the land use table currently shows 2905 square feet, but should be 2950 square feet. RESPONSE: The typo has been corrected. Department: Stormwater Engineering Contact: Dan Mogen, 970-224-6192, dmogen@fcgov.com Topic: General Comment Number: 1 Comment Originated: 08/31/2016 08/31/2016: Please note that all City construction detail drawings are to be used in their original, unaltered state. ANY modification(s) must be clearly distinguished and all City logos/identifiers must be removed from the modified detail. Detail drawings can be found in both .pdf and .dwg formats through the links to “Construction Drawings” on www.fcgov.com/utility-development. RESPONSE: All references made to “Fort Collins” on altered details have been removed from the plan set. Comment Number: 2 Comment Originated: 08/31/2016 08/31/2016: Please provide evidence that the detention basin is in compliance with drain times per Colorado Revised Statute 37-92-602(8). More information on this statute is available at http://tinyurl.com/RevisedStatuteMemo, and a spreadsheet to show compliance is available for download at http://tinyurl.com/ComplianceSpreadsheet. Please contact Dan Mogen at (970)224-6192 or dmogen@fcgov.com with any questions about this requirement or for assistance with the spreadsheet. RESPONSE: Please see updated Drainage Report dated Sept. 26th, 2016 titled “Drainage Report for Hess Land, LLC,” for all drainage information. Comment Number: 3 Comment Originated: 08/31/2016 08/31/2016: Please clarify the easement extents for the two detention basins as there seems to be discrepancy between the site plan and utility plans. While basin 1.0 seems to be covered on the utility plans, it does not appear to be on the site plan. Basin 2.0 does not appear to be covered by an easement on the western end. RESPONSE: Easement lines for Basin 2.0 have been updated to incorporate the entire pond 2 boundaries. Please see Grading Plan C-2.0 for more easement information. Comment Number: 4 Comment Originated: 08/31/2016 08/31/2016: More understanding of Basin 2.0 is needed. While it is clear that this will be combined with existing basin for Lot 19, clarification is needed for the outlet structure modifications as well as how the water quality capture volumes are being combined. RESPONSE: Please see updated Drainage Report dated Sept. 26th, 2016 titled “Drainage Report for Hess Land, LLC,” for all drainage information. Comment Number: 5 Comment Originated: 08/31/2016 08/31/2016: Additional details are needed for the proposed rain gardens. Please show the underdrains on the plans and detail the connection to the drywells. Are the drywells proposed to be open at the surface? It was understood that the drywells would be capped and the underdrains would be the only tie-in to the drywells. RESPONSE: Underdrain detail has been updated to show connection to dry well. Detail updated on C-4.2, rain garden cross section can be found on C-2.1 Drainage Plan. Comment Number: 6 Comment Originated: 08/31/2016 08/31/2016: Please see redlined report and plans. Please be sure to return these with future submittals. RESPONSE: Report has been updated and revised. New copy will be provided with this next submittal. Department: Technical Services Contact: Jeff County, 970-221-6588, jcounty@fcgov.com Topic: Building Elevations Comment Number: 3 Comment Originated: 08/31/2016 08/31/2016: No comments. Topic: Construction Drawings Comment Number: 5 Comment Originated: 08/31/2016 08/31/2016: There are line over text issues. See redlines. RESPONSE: Line over text issues have been resolved. Topic: Landscape Plans Comment Number: 2 Comment Originated: 08/31/2016 08/31/2016: No comments. Topic: Lighting Plan Comment Number: 4 Comment Originated: 08/31/2016 08/31/2016: No comments. Topic: Site Plan Comment Number: 1 Comment Originated: 08/31/2016 08/31/2016: There are line over text issues. See redlines. RESPONSE: Line over text corrected. Department: Water Conservation Contact: Eric Olson, 970-221-6704, eolson@fcgov.com Topic: General Comment Number: 1 Comment Originated: 08/29/2016 08/29/2016: Irrigation plans are required no later than at the time of building permit. The irrigation plans must comply with the provisions outlined in Section 3.2.1(J) of the Land Use Code. Direct questions concerning irrigation requirements to Eric Olson, at 221-6704 or eolson@fcgov.com RESPONSE: Acknowledged. Department: Zoning Contact: Noah Beals, 970-416-2313, nbeals@fcgov.com Topic: General Comment Number: 1 Comment Originated: 08/31/2016 08/31/2016: The Site plan sheet needs a SHEET INDEX. RESPONSE: Sheet index has been added. Comment Number: 2 Comment Originated: 08/31/2016 08/31/2016: Please locate the Mechanical equipment (RTU, boxes, conduit, AC units) on the plans (elevations, site and landscape). How is the equipment screened? RESPONSE: We are showing condenser units on the site and landscape plans and exterior elevations.