HomeMy WebLinkAboutMORNINGSTAR ASSISTED LIVING & MEMORY CARE - PDP - PDP130024 - CORRESPONDENCE -Community Development and
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 - fax
fcgov.com/developmentreview
September 06, 2013
Cathy Mathis
TB Group
444 Mountain Ave.
Berthoud, CO 80513
Comment Summary:
Department: Current Planning
Contact: Jason Holland, 970-224-6126, jholland@fcgov.com
Topic: Building Elevations
Staff would like to see additional context shown with or in addition to the west elevation -- showing the
tapered retaining wall, fencing and landscaping. This could be an elevation view or perspective.
Comment Number: 9 Comment Originated: 09/04/2013
Topic: General
Staff needs more detailed information about the "assisted living" portion of the project. The LUC does
not define assisted living, and this part of the project program needs to be defined as either
independent living, multi-family, or intermediate health care. Staff's understanding at conceptual was
that all of the units would fall under the definition of intermediate health care. The main issue is whether
the residents will have cars and need additional parking. Please provide a note and clarification on
the plan that explains what will comprise "studios, single and doubles" and how these assisted living
units comply with the Long Term Care LUC definition.
Comment Number: 1 Comment Originated: 09/04/2013
Please provide more detailed context surrounding the site showing existing buildings, parking and
trees, and with line hierarchy that make the elements more understandable. Refer to civil plan format.
We recommend showing the overall site plan at 1:40 to show more context and a detail sheet of the
west portion of the property showing plan enlargement of wall, fence, landscaping, sections and
details.
Comment Number: 2 Comment Originated: 09/04/2013
Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of
the above referenced project. If you have questions about any comments, you may contact the individual
commenter or direct your questions through the Project Planner, Jason Holland, at 970-224-6126 or
jholland@fcgov.com.
RE: Morningstar Assisted Living & Memory Care, PDP130024, Round Number 1
Page 1 of 8
Please explore ways to further articulate the fence and wall combination both horizontally and
vertically, and make it more clear on the plans where the fence is going. Make sure the fencing plan
matches between he civil and site plan sheets.
Comment Number: 8 Comment Originated: 09/04/2013
Topic: Landscape Plans
The landscape plan needs to be reformatted. Plants are not readable at 1:30. Tree labels at tree
centers are not readable and are awkard at 90 degrees. The smaller plant list symbols are not
readable. The evergreen tree key code is too small to be readable. The shade tree key code at the
center of the symbol makes the plans difficult to read and there is no center trunk demarcation.
Comment Number: 3 Comment Originated: 09/04/2013
More evergreen trees need to be incorporated into the foundation planting around the building as well
as along the top and bottom of the retaining wall. See redlines for minor comments.
Comment Number: 4 Comment Originated: 09/04/2013
Label existing trees and add/or add them to the legend. Show approximate location of existing trees
to the west and north for context, it appears that there are more than what is shown.
Comment Number: 5 Comment Originated: 09/04/2013
Topic: Site Plan
Please show materials, color and design details for the retaining wall. Coordinate with the utility plans
and label approximate height of the wall at various locations for informational purposes.
Comment Number: 6 Comment Originated: 09/04/2013
Dash in on the building footprint areas that are one story vs. two story. Also show the demarcation
between memory care and the rest of the building.
Comment Number: 7 Comment Originated: 09/04/2013
Department: Engineering Development Review
Contact: Marc Virata, 970-221-6567, mvirata@fcgov.com
Topic: General
09/04/2013: The northernmost driveway out to Lochwood Drive needs to lineup with the driveway
across the street.
Comment Number: 2 Comment Originated: 09/04/2013
09/04/2013: The geotech report indicated the presence of high groundwater and the need to dewater
the site along with the installation of an underdrain system. The implementation of an underdrain
system should indicate an outfall design for the underdrain system on the construction plan set. There
is a concern that if the outfall for the underdrain system is not specified at this time and designed for,
the outfall may discharge in manner that's of negative impact such as spilling onto public sidewalk, or
creating a landscape area that's saturated with water.
Comment Number: 3 Comment Originated: 09/04/2013
09/04/2013: To the extent that the geotech report indicates the presence and concern of high
groundwater, are the proposed LID measures going to implement underdrain systems beneath them?
It seems that the drainage report and geotech report don't cross reference each other with regards to
their findings and recommendations. Shouldn't the geotech report provide some analysis on the site's
proposed use of LID measures for example and whether the porous pavers are able to infiltrate without
interference from groundwater?
Comment Number: 4 Comment Originated: 09/04/2013
Page 2 of 8
09/04/2013: A plat was not found in my submittal documents for review. Was one submitted?
Comment Number: 5 Comment Originated: 09/04/2013
09/04/2013: The plans should be specifying the amount of parkway strip being proposed along
Lochwood Drive.
Comment Number: 6 Comment Originated: 09/04/2013
09/04/2013: The construction plans in addition to specifying the amount of parkway strip along
Lochwood Drive, should be providing a typical cross-section along Lochwood Drive to indicate curb
and gutter type, parkway measured from the face of curb, and detached sidewalk width.
Comment Number: 7 Comment Originated: 09/04/2013
09/04/2013: The construction plans should be showing the removal of the existing attached
sidewalk/hollywood curb where detached sidewalk is being installed and show proposed patching
along Lochwood Drive for the installation of the new (presumably vertical) curb and gutter. Add the
City's standard note regarding limits of street repair: Limits of street cut are approximate. Final limits
are to be determined in the field by the City Engineering Inspector. All repairs to be in accordance
with City street repair standards.
Comment Number: 8 Comment Originated: 09/04/2013
09/04/2013: The access ramp at the corner of Lochwood Drive and Horsetooth Road leads to the
middle and isn't directional. With the removal of the hollywood curb and gutter needing to be brought
to the access ramp, the access ramp should be rebuilt to be directional (facing east) meeting City
standards.
Comment Number: 9 Comment Originated: 09/04/2013
09/04/2013: Please correct the spelling of Lochwood Drive on the site plan, and provide street name
labels on the landscape plan.
Comment Number: 10 Comment Originated: 09/04/2013
Contact: Sheri Langenberger, 970-221-6573, slangenberger@fcgov.com
Topic: General
08/19/2013: The project owes and additonal $122.50 for the TDRF for PDP. The site acreage was
miscalculated. This can be paid at the time of final payment after hearing.
Comment Number: 1 Comment Originated: 08/19/2013
Department: Environmental Planning
Contact: Lindsay Ex, 970-224-6143, lex@fcgov.com
Topic: General
09/04/2013: At time of final plan submittal, please include a detailed species description of the
Arkansas Valley seed mix, including the rates of seed mix to be applied.
Comment Number: 1 Comment Originated: 09/04/2013
Department: Forestry
Contact: Tim Buchanan, 970-221-6361, tbuchanan@fcgov.com
Topic: Landscape Plans
09/06/2013:
If there will be any street lights then show locations on landscape plan and provide tree separation of
40 feet for shade trees or 15 feet for ornamental trees.
Comment Number: 1 Comment Originated: 09/06/2013
Page 3 of 8
09/06/2013:
If there are any existing trees on the site schedule an meeting with The City Forester to review and
inventory.
Comment Number: 2 Comment Originated: 09/06/2013
09/06/2013: Will any off-site trees be impacted by proposed construction?
Comment Number: 3 Comment Originated: 09/06/2013
09/06/2013: Tree protection note # 7 does not seem to apply and may not be needed.
Comment Number: 4 Comment Originated: 09/06/2013
09/06/2013: Consider using lanceleaf cottonwood or plains cottonwood in place of the narrowleaf
cottonwood. The narrowleaf cottonwood produces and abundance of root suckers that can causes
maintenance problems.
Comment Number: 5 Comment Originated: 09/06/2013
Department: Light And Power
Contact: Doug Martine, 970-224-6152, dmartine@fcgov.com
Topic: General
08/19/2013: The electric transformer will likely be 84" wide x 73" deep. In addition, a minimum of 3
feet unobstructed clearance is required on the back and two sides, and 8 feet in front of the
transformer. It is not clear on the utility plan if there is adequate space for the transformer.
Comment Number: 1 Comment Originated: 08/19/2013
08/19/2013: The developer will need to coordinate power requirements and electric development
charges with Light & Power Engineering (970)221-6700.
Comment Number: 2 Comment Originated: 08/19/2013
08/19/2013: After plans are final, please send an AutoCad (version 2008) of the site/utility plan to Terry
Cox at TCOX@FCGOV.COM.
Comment Number: 3 Comment Originated: 08/19/2013
08/19/2013: A landscape plan showing planned streetlights was sent to the landscape architect on
Aug. 19, 2013. These lights need to be shown on the landscape plan and street tree locations
adjusted to provide a minimum of 40 feet between trees and lights (15 feet if tree is an ornamental
type).
Comment Number: 4 Comment Originated: 08/19/2013
Department: PFA
Contact: Jim Lynxwiler, 970-416-2869, jlynxwiler@poudre-fire.org
Topic: General
09/03/2013: PUBLIC-SAFETY RADIO AMPLIFICATION SYSTEM
New buildings greater than 50,000 square feet will require a fire department, emergency
communication system evaluation after the core/shell but prior to final build out. For the purposes of
this section, fire walls shall not be used to define separate buildings. Where adequate radio coverage
cannot be established within a building, public-safety radio amplification systems shall be designed
and installed in accordance with criteria established by the Poudre Fire Authority. Poudre Fire Authority
Bureau Admin Policy #07-01
Comment Number: 1 Comment Originated: 09/03/2013
Page 4 of 8
09/03/2013: FIRE ACCESS FOR STRUCTURES EXCEEDING 30' (OR THREE OR MORE STORIES) IN
HEIGHT
In order to accommodate aerial fire apparatus access (ladder trucks), required fire lanes shall be 30
foot wide minimum on at least one long side of the building. At least one of the required access routes
meeting this condition shall be located within a minimum of 15 feet and a maximum of 30 feet from the
building, and shall be positioned parallel to one entire side of the building. 2006 International Fire
Code Appendix D; Poudre Fire Authority Administrative Policy 85-5
This code requirement is not currently being met with the current site plan and further discussion is
needed.
Comment Number: 2 Comment Originated: 09/03/2013
09/03/2013: HYDRANT PLACEMENT
The relocation of the hydrant on the SE corner of the building, shall be reviewed in future plans
submittals. One additional hydrant on the west side of the building is also needed.
Comment Number: 3 Comment Originated: 09/03/2013
09/03/2013: FDC
Fire Department Connections shall be installed in accordance with NFPA standards. Fire department
connections shall be located on the street side of buildings, fully visible and recognizable from the
street or nearest point of fire department vehicle access. The location of the FDC shall be approved
by the fire department.
2006 International Fire Code 912.2
Comment Number: 4 Comment Originated: 09/03/2013
09/03/2013: 2012 IFC CODE ADOPTION
Please be advised the Poudre Fire Authority and the City of Fort Collins are currently in the process of
reviewing the 2012 International Fire Code in preparation for its adoption in 2014. Building plan reviews
shall be subject to the adopted version of the fire code in place at the time of plan review submittal
and permit application.
Comment Number: 5 Comment Originated: 09/03/2013
Department: Stormwater Engineering
Contact: Jesse Schlam, 970-218-2932, jschlam@fcgov.com
Topic: Erosion Control
08/27/2013: The site disturbs more than 10,000 sq-ft and in a sensitive area, therefore Erosion and
Sediment Control Materials need to be submitted for FDP. The erosion control requirements are in the
Stormwater Design Criteria under the Amendments of Volume 3 Chapter 7 Section 1.3.3. Current
Erosion Control Materials Submitted does not meet requirements. Please submit; Erosion Control
Plan, Erosion Control Report, and an Escrow / Security Calculation. If you need clarification concerning
this section, or if there are any questions please contact Jesse Schlam 970-218-2932 or email @
jschlam@fcgov.com
Comment Number: 1 Comment Originated: 08/27/2013
Contact: Wes Lamarque, 970-416-2418, wlamarque@fcgov.com
Topic: General
09/03/2013: Please provide quantity and quality detention calculations in the drainage report to verify
capacities.
Comment Number: 2 Comment Originated: 09/03/2013
Page 5 of 8
09/03/2013: Both detention ponds need to have spillways directed to the major swale.
Comment Number: 3 Comment Originated: 09/03/2013
09/03/2013: Please document on an exhibit what land area is being treated by a LID technique.
Comment Number: 4 Comment Originated: 09/03/2013
09/03/2013: The site is quite high. Lowering the site a foot or two would be desired.
Comment Number: 5 Comment Originated: 09/03/2013
09/03/2013: The retaining wall will require a building permit.
Comment Number: 6 Comment Originated: 09/03/2013
09/04/2013: Please provide a maintenance agreement for the swale that is shared by the two
properties. If an agreement can not be formalized, please provide a maintenance obligation within the
drainage report that lays out the responsibilities of the Developer.
Comment Number: 7 Comment Originated: 09/04/2013
Department: Technical Services
Contact: Jeff County, 970-221-6588, jcounty@fcgov.com
Topic: Building Elevations
09/03/2013: There is a line over text issue on sheet EL-1. See redlines.
Comment Number: 1 Comment Originated: 09/03/2013
Topic: Construction Drawings
09/03/2013: Please change the index on sheet 1 to read "Drainage & Erosion Control Plan" for the
sheet 4. See redlines.
Comment Number: 2 Comment Originated: 09/03/2013
09/03/2013: There are line over text issues on sheets UT (2 of 4), GR (3 of 4) & DR (4 of 4). See
redlines.
Comment Number: 3 Comment Originated: 09/03/2013
09/03/2013: Please rotate the street names marked on sheet DR (4 of 4) 180 degrees to read from the
right side of the plan sheet. See redlines.
Comment Number: 4 Comment Originated: 09/03/2013
Topic: General
09/03/2013: Why is there not a Subdivision Plat included for this project? This project is on an
unplatted piece of property.
Comment Number: 5 Comment Originated: 09/03/2013
Topic: Landscape Plans
09/03/2013: There are line over text issues on sheet 2. See redlines.
Comment Number: 6 Comment Originated: 09/03/2013
09/03/2013: Please mask all text that is within hatched areas on sheet 2. See redlines.
Comment Number: 7 Comment Originated: 09/03/2013
Topic: Lighting Plan
09/03/2013: Please add a north arrow & scale to sheet PTP1. See redlines.
Comment Number: 8 Comment Originated: 09/03/2013
Page 6 of 8
Topic: Site Plan
09/03/2013: Please rotate the street names marked on sheet 1 180 degrees to read from the right
side of the plan sheet. See redlines.
Comment Number: 9 Comment Originated: 09/03/2013
09/03/2013: There are line over text issues on sheet 1. See redlines.
Comment Number: 10 Comment Originated: 09/03/2013
Department: Traffic Operation
Contact: Ward Stanford, 970-221-6820, wstanford@fcgov.com
Topic: Construction Drawings
09/04/2013: The north access should align with the northern access of the daycare center, per
LCUASS requirements.
Comment Number: 3 Comment Originated: 09/04/2013
Topic: Traffic Impact Study
09/03/2013: TIS is accepted.
Comment Number: 1 Comment Originated: 09/03/2013
09/04/2013: A west bound right turn lane is needed in the existing condition per Figure 8-4, LCUASS,
and this project adds traffic to that right turn. As such this project has a responsibility to construct a west
bound right turn lane on Horsetooth at Lochwood. Traffic staff recognizes the addition of such turn lane
would also cause the removal of numerous large existing trees and therefore would suggest the
applicant submit a variance request to remove the responsibility of constructing the right turn lane.
Comment Number: 2 Comment Originated: 09/04/2013
Department: Water-Wastewater Engineering
Contact: Roger Buffington, 970-221-6854, rbuffington@fcgov.com
Topic: Construction Drawings
09/03/2013: Label sewer service clean-outs in paved areas "traffic-rated".
Comment Number: 2 Comment Originated: 09/03/2013
Topic: General
09/03/2013: Show/label curb stop on the 2" water service.
Comment Number: 3 Comment Originated: 09/03/2013
Topic: Landscape Plans
09/03/2013: Adjust plantings to provide the required separation distances from water/sewer lines.
Comment Number: 1 Comment Originated: 09/03/2013
Department: Zoning
Contact: Peter Barnes, 970-416-2355, pbarnes@fcgov.com
Topic: General
Page 7 of 8
08/20/2013: Need further clarification of the use. If the units have kitchens, and if they aren't classified
as an 'independent living facility' per the definition of Long Term Care Facility in Article 5 of the Land
Use Code, then the building is considered a multi-family dwelling. The parking requirements for
multi-family are much greater. i.e. if all 78 units are studios or one bedroom, then a minimum of 117
parking spaces are required.
Comment Number: 1 Comment Originated: 08/20/2013
Topic: Site Plan
08/20/2013: Handicap parking stalls shouldn't be parallel parking spaces. If the HC person is on the
drivers side and needs to remove a wheel chair from the back seat, the driver's side doors will be
open into the drive aisle for a longer than normal period of time. That would create an unsafe
condition.
Comment Number: 2 Comment Originated: 08/20/2013
08/20/2013: Provide a detail drawing of the trash enclosure.
Comment Number: 3 Comment Originated: 08/20/2013
08/20/2013: Show some building dimensions on the site plan.
Comment Number: 4 Comment Originated: 08/20/2013
Page 8 of 8