Loading...
HomeMy WebLinkAboutCSU HEALTH CENTER / GF WAIRDS REPLAT & UTILITY PLAN - PDP/FDP - FDP150039 - REPORTS - CITY STAFFCSU Health and Medical Center Plat Administrative Hearing January 7, 2016 1 CSU Health and Medical Center Plat 2 Plat Area: 5.161 acres total, includes: • 2 lots: 4.910 acres • ROW: 0.198 acres • Alley: 0.053 acres Background - Medical Center Site Plan 3 • Site plan approved as a Site Plan Advisory Review (SPAR) by the Planning and Zoning Board on October 8, 2015 • 4 story building, surface parking lot, on-site detention, street improvements • Zoning: Community Commercial (CC) zone district SPAR Submittal Medical Center Site Plan 0’ 10’ 20’ 40’ NORTH 20’ R.O.W September September 28, 2, 2015 2015 West P r o s p e c t R o a d FFE 5001 C o l l e g e A v e n u e M a s o n C o r r i d o r L a k e S t r e e t Po Potential Future re Bus Dro rop-Off 15’ 10’ 60’Setback 16’ 28’ 28’ Mason Co Corridor Tr Tra ransit Stop Serviccee Co Court Genera rator/ r/ Tr Tra ransfo former Mixe xed Ashlar Stone Wa Wall: Buff/ ff/Red Mix Red Sandstone Pa Panel Wa Wall to Match Building Plaza/Pa Patio Rehab/ b/Phys ysical Thera rapy Space Identification Signage and Monument Potential Future re Condition Public Gathering Enhanced Plaza Emerg rgency Access 28’ 30’ 28 28’ 8’ HC HC HC HC HC HC HC HC 30’ 30’ 28 28’ 8’ Tr Tra rash & Recyyccling Loading Existing House Existing House Pro roperty Line Pro roperty Line Existing House Existing Connection Existing Access fr fro rom College Av Ave ve. Existing Access fr fro rom College Av Ave ve. SPAR Submittal Medical Center Design Evolution Responding to City Staff Review 0’ 10’ 20’ 40’ NORTH KEY A Eliminated College Ave. access point B Eliminated Prospect Rd. access point C Shifted building to the north, providing greater setback from Prospect Rd. D Provided direct access from MAX stop to building entry E Increased size of water quality feature, removed parking F Site to take water from existing streets and detain/ treat G Plan accommodates future bus pullout transfer point for Transfort H Detached widened sidewalk per West Central Area plan vision I Preserve existing street trees where feasible along College Ave. J Manipulate grade and provide signifi cant vegetation along service court wall to buffer from College Ave. Use enhanced material for wall. K Detached widened sidewalk along College Ave. L Plan accommodates future intersection improvements at College Ave./ Prospect Rd. M Site access on Lake Street only, align infrastructure with existing to North N Direct pedestrian access through parking lot IDENTIFIED IN SPAR SUBMITTAL COMMENTS O Widen trail section for pedestrians along Mason Trail P Protect Signifi cant trees on site Q Widen College Ave. Sidewalk to 10’ A J K I L O Q P P P P P H C G F E D M M N F B September September 28, 2, 2015 2015 SPAR Submittal Medical Center Contextual Circulation Plan NORTH College Avenue Parking Structure Complete Summer 2016 Medical Center Complete Spring 2017 W. Pitkin St. W. Lake St. 920 parking spaces w/ new structure 106 parking spaces MAX Prospect Station Proposed Bus Stop S. College Ave. P P W. Prospect Rd. September 2, 2015 SPAR Submittal Medical Center Existing Conditions/ Site Photos EXISTING CONDITIONS A B C D B WEST PROSPECT ROAD WEST LAKE STREET APPROXIMATE PROJECT LIMITS +/- 4 AC. SOUTH COLLEGE AVENUE MAX PROSPECT STATION E A C D E FG HI J H I F G J September 2, 2015 SOUTH ELEVATION WEST ELEVATION EAST ELEVATION SPAR Submittal Medical Center Building Elevations September September 28, 2, 2015 2015 ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ A Replat of Multiple Parcels of Land, Situate in the Southeast Quarter of Section 14, Township 7 North, Range 69 West of the 6th P.M., City of Fort Collins, County of Larimer, State of Colorado ³ ´ ³ ´ VICINITY MAP ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ KING SURVEYORS 650 E. Garden Drive | Windsor, Colorado 80550 phone: (970) 686-5011 | email: info@KingSurveyors.com 1 N:\2014941-B\DWG\2014941B-SUB.dwg, 12/11/2015 10:28:12 AM LOT 1 201,987 SQ.FT. 4.637 ACRES DEDICATED RIGHT OF WAY 6,356 SQ.FT. 0.146 ACRES LOT 2 11,917 SQ.FT. 0.273 ACRES BLOCK 1 DEDICATED RIGHT OF WAY 1,343 SQ.FT. 0.031 ACRES DEDICATED RIGHT OF WAY 896 SQ.FT. 0.021 ACRES EXISTING 20' ALLEY 2,333 SQ.FT. 0.053 ACRES LEGEND LOT 1 DETAIL A DETAIL B A Replat of Multiple Parcels of Land, Situate in the Southeast Quarter of Section 14, Township 7 North, Range 69 West of the 6th P.M., City of Fort Collins, County of Larimer, State of Colorado KING SURVEYORS 650 E. Garden Drive | Windsor, Colorado 80550 phone: (970) 686-5011 | email: info@KingSurveyors.com 2 N:\2014941-B\DWG\2014941B-SUB.dwg, 12/11/2015 10:28:19 AM COLORADO STATE UNIVERSITY HEALTH AND MEDICAL CENTER 151 WEST LAKE STREET FORT COLLINS, COLORADO LOCATED IN THE SOUTHEAST QUARTER OF SECTION 14, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PM, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO DECEMBER 11, 2015 UTILITY PLANS FOR Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION ’ Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 303 . 623 . 2836 Fax LAKE STREET SOUTH COLLEGE AVENUE MASON CORRIDOR TRANSITWAY WEST PROSPECT ROAD C0.3 DEMOLITION PLAN Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 LAKE STREET SOUTH COLLEGE AVENUE MASON CORRIDOR TRANSITWAY WEST PROSPECT ROAD CE1.0 EROSION CONTROL PLAN Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 CE1.1 SWMP & EROSION CONTROL DETAILS Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 CE1.2 EROSION CONTROL DETAILS Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 LAKE STREET SOUTH COLLEGE AVENUE MASON CORRIDOR TRANSITWAY WEST PROSPECT ROAD 4997.54 BM NGS S402 N=1450392.08 E=3117761.68 4998.70 CP-PED N=1450710.49 E=3118125.26 5004.04 CP-MAX N=1450663.34 E=3117808.94 4993.53 CP-X N=1450178.31 E=3118301.95 4998.66 CP-MAG N=1450139.24 E=3117869.11 4994.80 CP-ALLEY N=1450139.03 E=3118105.77 C1.0 OVERALL GRADING PLAN Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / MASON CORRIDOR TRANSITWAY LAKE STREET Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 LAKE STREET SOUTH COLLEGE AVENUE Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 MASON CORRIDOR TRANSITWAY Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 303 . 623 . 2836 Fax SOUTH COLLEGE AVENUE Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 303 . 623 . 2836 Fax WEST PROSPECT ROAD MASON CORRIDOR TRANSITWA Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 SOUTH COLLEGE AVENUE WEST PROSPECT ROAD Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 MASON CORRIDOR TRANSITWAY LAKE STREET C1.7 STORM PLAN & PROFILE Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 SOUTH COLLEGE AVENUE C1.8 STORM PLAN & PROFILE Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 MASON CORRIDOR TRANSI C1.9 STORM PLAN & PROFILE Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 SOUTH COLLEGE AVENUE MASON CORRIDOR TRANSITWAY WEST PROSPECT ROAD C1.10 ROOF AND AREA DRAIN PLAN Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 A A CD1.0 GRADING & DRAINAGE DETAILS Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 CD1.1 GRADING & DRAINAGE DETAILS Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 DWG SIZE A SCALE 1:1 SHEET 1 OF 1 DWG NO. 7003-110-009 8 IN - 30 IN INLINE DRAIN SPECIFICATIONS TITLE PROJECT NO./NAME MATERIAL DATE REVISED BY DATE 03-10-00 DRAWN BY CJA 09-09-13 CCA THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT OR POSSESSION OF THIS PRINT DOES NOT CONFER, TRANSFER, OR LICENSE THE USE OF THE DESIGN OR TECHNICAL INFORMATION SHOWN HEREIN REPRODUCTION OF THIS PRINT OR ANY INFORMATION CONTAINED HEREIN, OR MANUFACTURE OF ANY ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN PERMISSION FROM NYLOPLAST. ©2013 NYLOPLAST REV G 3130 VERONA AVE BUFORD, GA 30518 PHN (770) 932-2443 FAX (770) 932-2490 www.nyloplast-us.com DWG SIZE A SCALE 1:40 SHEET 1 OF 1 DWG NO. 7001-110-042 REV D 3130 VERONA AVE BUFORD, GA 30518 PHN (770) 932-2443 FAX (770) 932-2490 www.nyloplast-us.com 8 IN - 30 IN TYPICAL INSTALLATION OPTIONS TITLE PROJECT NO./NAME MATERIAL DATE REVISED BY DATE 8-10-00 THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH DRAWN BY AWA NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT OR POSSESSION OF THIS PRINT DOES NOT CONFER, TRANSFER, OR LICENSE THE USE OF THE DESIGN OR TECHNICAL INFORMATION SHOWN HEREIN REPRODUCTION OF THIS PRINT OR ANY INFORMATION CONTAINED HEREIN, OR MANUFACTURE OF ANY ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN PERMISSION FROM NYLOPLAST. 1-6-10 EBC DUCTILE IRON DO NOT POLLUTE DRAINS TO WATERWAYS NYLOPLAST S T A L O P L Y N D SOUTH COLLEGE AVENUE WEST PROSPECT ROAD MASON CORRIDOR TRANSITWAY LAKE STREET Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 WEST PROSPECT ROAD C2.1 WATER LINE PLAN & PROFILE Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 LAKE STREET C2.2 SEWER PLAN & PROFILE Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 WEST PROSPECT ROAD C2.3 SEWER PLAN & PROFILE Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 NOTES: CD2.0 UTILITY DETAILS Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 COMPACTED GRANULAR MATERIAL CONFORMING TO CDDH #67 LOWER LIMIT OF TRENCH WALL SLOPING INITIAL LIFT * 12 IN. MIN. PIPE O.D. 4 IN. MIN. TRENCH WIDTH AS SPECIFIED IN SECTION 02221 COMPACTED GRANULAR MATERIAL CONFORMING TO CDDH #67 * BEDDING REQUIRMENTS WW-1 ALTERNATE BASE POURED INVERT PRECAST MANHOLE BASE 2 IN. MIN. SLOPE 1 IN. MIN. 8 IN. MIN. 6 IN. 15 IN. OR LESS 48 IN. 18 IN. TO 30 IN. 60 IN. OVER 30 INCHES 72 IN. MIN. MANHOLE MINIMUM INSIDE DIAMETER OF DIAMETER MANHOLE SHALL BE AS FOLLOWS: PIPE SIZE 5 FT. MIN. DEPTH CONCRETE ADJUSTMENT SHIMS GROUTED INSIDE ASTM C-478 ECCENTRIC CONE PRE-FORMED PLASTIC GASKET ASTM C-478 MANHOLE SECTIONS GROUT BASE TO BARREL SECTION ON INSIDE PRE-FORMED PLASTIC GASKET CAST-IN-PLACE CONCRETE BASE 16 IN. MAX. FINISHED GRADE 30 IN. MIN. 48 IN. MAX. VARIABLE 28 IN. MAX. 24 IN. SEE TABLE 6 IN. 12 IN. SLOPE 1 IN./FT. 18 IN. MAX. MANHOLE RUNGS 12 IN. O.C. 8 IN. MIN STANDARD MANHOLE LAKE STREET SOUTH COLLEGE AVENUE MASON CORRIDOR TRANSITWAY WEST PROSPECT ROAD C3.0 HORIZONTAL CONTROL PLAN Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 C3.1 LINE AND CURVE TABLES Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 CD3.0 SITE DETAILS Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 NOTES: 1. THE SIGN PLATE SHALL BE A MINIMUM OF 12"X18" WITH A THICKNESS OF .080 ALUMINUM CONSTRUCTION. 2. THE SIGN FACE SHALL HAVE A WHITE REFLECTIVE BACKGROUND WITH A RED LEGEND. USE THE STANDARD 3M SCOTCHLITE SIGN FACE NUMBER R7-32 OR EQUIVALENT, WITH RED LETTERING AS SHOWN ABOVE. 3. ARROWS MAY BE NEEDED (LEFT, RIGHT OR DOUBLE), TO DESIGNATE BEGIN AND END OF NO PARKING AREA. FIRE LANE NO PARKING BY ORDER OF THE FIRE MARSHAL STANDARD FIRE LANE SIGN DETAIL UNIVERSAL FIRE LANE SIGN DETAIL 18" 2" 1 1/2" 3/4" 12" 12" FIRE LANE COLOR SCHEDULE BACKGROUND "P" RED WHITE BLACK LEGEND, CIRCLE DIAGONAL, BORDER, "ARROW", "FIRE LANE" (FORT COLLINS ONLY) Double Lines Normal Width Line 4" White 4" Yellow 4" Space 4" White Preferential lane symbol (6' X 4') for designated bikeways. White pavement marking placed 65' (min) from the projected flowline and Projected Flowline (FL) NO CROSSPAN Continental bars (9' X 1.5'): NO CROSSPAN OR EXISTING CROSSPAN White Stop Bar (1.5' X Length) 30' Gaps 3:1 Ratio 10' Segments 4" White Broken Line STANDARD NO STOP BAR SPECIFIED STOP BAR SPECIFIED STOP BAR SPECIFIED EXISTING CROSSPAN Crosspan exits (no stop bar) -- shall CD3.2 SITE DETAILS Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 CD3.3 SITE DETAILS Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 SOUTH COLLEGE AVE WEST PROSPECT ROAD C4.0 PROSPECT ROAD IMPROVEMENTS PLAN (FOR REFERENCE ONLY) Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner No crosspan -- shall be positioned along projected flowline. match the edge of the pan. Crosspan exits (stop bar specified) -- shall be positioned along projected flowline overlapping 4' of crosspan. 1 2 3 FL to stop bar 14.5' Projected 14.5' Stop Bar to FL 13' 9' 1.5' 6' Crosspan 4' 4' 4' NOTES: Continental crosswalk bars shall be placed centered on each lane line & in the center of each lane. (Lanes 5' wide or less shall not receive a bar centered in the lane.) Both outside Continental bars shall be centered on the curb & gutter when possible. If 6' crosspan exists, bars to match pan edge to 13' from projected FL. Exception: The downstream bike lane line shall terminate at the curb return. NOTE: All longitudinal (lane) striping shall terminate at the continental crosswalk bars when no stop bar exists. If a stop bar is specified, the striping shall terminate at the stop bar. 65' (min) centered on bike lane. CD3.1 SITE DETAILS Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner WW-3 PLAN VIEW CROSS VIEW 45 ELBOW SERVICE WYE 8 IN. PVC SEWER PIPE COMPACTED GRANULAR MATERIAL AIR-TIGHT PLUG WITH 4 IN. X 4 IN. MARKER UNYIELDING PIPE BEDDING OF COMPACTED ROCK OR LEAN CONCRETE PVC SEWER PIPE NOTE: WYE CONNECTION NOT ALLOWED ON VCP LEAN CONCRETE o 20 MIN. o 45 MAX. o TRENCH UNYIELDING PIPE BEDDING OF COMPACTED ROCK OR 4 IN. X 4 IN. MARKER AIR-TIGHT PLUG SERVICE WYE DETAIL WW-9 SECTION A-A PLAN A A CD2.1 UTILITY DETAILS Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner Denver . Colorado . 80204 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER C2.0 UTILITY PLAN CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner U C T I L E I R O N A S T L P O L Y N D U C T I L E I R O N DUCTILE IRON DO NOT POLLUTE DRAINS TO WATERWAYS NYLOPLAST WHEN ARE DRAIN BASINS USED? 2808AG _ _ X 2810AG _ _ X 2812AG _ _ X 2815AG _ _ X 2818AG _ _ X 2824AG _ _ X 2830AG _ _ X WHEN ARE INLINE DRAINS USED? 2708AG _ _ X 2710AG _ _ X 2712AG _ _ X 2715AG _ _ X 2718AG _ _ X 2724AG _ _ X 2730AG _ _ X TYPICAL INSTALLATIONS TYPICAL INSTALLATION OF NYLOPLAST DRAIN BASIN AND INLINE DRAIN 1: TO ENTER AN EXISTING LINE USING A TEE & RISER 2: AT THE BEGINNING OF A DRAIN LINE USING AN ELBOW & RISER TEE ELBOW 12" DRAIN BASIN (2) INLET & OUTLET ADAPTERS CAN BE PUT ON ANY ANGLE 1: TO CHANGE ELEVATION 2: TO CHANGE PIPE DIAMETER 3: TO CHANGE PIPE TYPE 4: FOR SHALLOW APPLICATIONS 5: TO CHANGE DIRECTION A° RISER DRAIN BASIN INLINE DRAIN 10" INLINE DRAIN 10" INLINE DRAIN (3) VARIABLE ELEVATION WATERTIGHT ADAPTERS AVAILABLE FOR MOST COMMON PLASTIC PIPING SYSTEMS 8" 6" CORRUGATED HDPE PIPE SMOOTH WALL PVC 1 - STRUCTURES & ADAPTERS AVAILABLE IN SIZES 8" - 30" 2 - ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°, TO DETERMINE MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING NO. 7001-110-012 3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO SHIPPING RESTRICTIONS SEE DRAWING NO. 7001-110-065 ® ©2010 NYLOPLAST DWG SIZE A SCALE 1:25 SHEET 1 OF 1 DWG NO. 7001-110-340 REV E 3130 VERONA AVE BUFORD, GA 30518 PHN (770) 932-2443 FAX (770) 932-2490 www.nyloplast-us.com 12 IN - 30 IN DRAIN BASIN & INLINE DRAIN TURF TRAFFIC INSTALLATION TITLE PROJECT NO./NAME MATERIAL DATE REVISED BY DATE 01-05-09 THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH DRAWN BY EBC NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT OR POSSESSION OF THIS PRINT DOES NOT CONFER, TRANSFER, OR LICENSE THE USE OF THE DESIGN OR TECHNICAL INFORMATION SHOWN HEREIN REPRODUCTION OF THIS PRINT OR ANY INFORMATION CONTAINED HEREIN, OR MANUFACTURE OF ANY ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN PERMISSION FROM NYLOPLAST. 12" - 30" DRAIN BASIN 12" - 30" INLINE DRAIN THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I OR CLASS II MATERIAL AS DEFINED IN ASTM D2321. BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE WELL PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321. NYLOPLAST TURF TRAFFIC INSTALLATION TOP SOIL FRAME & GRATE/SOLID COVER ® ©2013 NYLOPLAST 12-03-14 NMH TRAFFIC LOADS: CONCRETE SLAB DIMENSIONS ARE FOR GUIDELINE PURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE DESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS, TRAFFIC LOADING, & OTHER APPLICABLE DESIGN FACTORS. 8" MIN THICKNESS GUIDELINE 1. GRATES/SOLID COVERS SHALL MEET H-20 LOAD RATING FOR 30" PEDESTRIAN & 12" - 30" STANDARD & SOLID 2. DESIGN SHOULD ACCOUNT FOR ROOT DEPTH TO ALLOW TURF TO GROW AND PREVENT EROSION AROUND GRATE SO THAT HAZARDS DO NOT FORM. 4" MIN ON 12" - 24" 6" MIN ON 30" MINIMUM PIPE BURIAL DEPTH PER PIPE MANUFACTURER RECOMMENDATION BOTTOM FLANGE OF FRAME MUST BE SUPPORTED BY CONCRETE COLLAR TOP SOIL (2) (2) MIN DEPTH FOR TURF 18" MIN THICKNESS 18" MIN THICKNESS BOTTOM FLANGE OF FRAME MUST BE SUPPORTED BY CONCRETE COLLAR DWG SIZE A SCALE 1:20 SHEET 1 OF 1 DWG NO. 7003-110-025 REV D 3130 VERONA AVE BUFORD, GA 30518 PHN (770) 932-2443 FAX (770) 932-2490 www.nyloplast-us.com 12 IN INLINE DRAIN QUICK SPEC INSTALLATION DETAIL TITLE PROJECT NO./NAME MATERIAL DATE REVISED BY DATE 04-03-06 DRAWN BY EBC 08-19-13 CCA MINIMUM PIPE BURIAL DEPTH PER PIPE MANUFACTURER RECOMMENDATION INVERT ACCORDING TO PLANS/TAKE OFF NYLOPLAST 12" INLINE DRAIN: 2712AG _ _ X (3) VARIOUS TYPES OF INLET & OUTLET ADAPTERS AVAILABLE: 4" - 12" FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL, ADS/HANCOR SINGLE WALL), N-12 HP, PVC SEWER (EX: SDR 35), PVC DWV (EX: SCH 40), PVC C900/C905, CORRUGATED & RIBBED PVC (CORRUGATED HDPE SHOWN) THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT OR POSSESSION OF THIS PRINT DOES NOT CONFER, TRANSFER, OR LICENSE THE USE OF THE DESIGN OR TECHNICAL INFORMATION SHOWN HEREIN REPRODUCTION OF THIS PRINT OR ANY INFORMATION CONTAINED HEREIN, OR MANUFACTURE OF ANY ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN PERMISSION FROM NYLOPLAST. 1 - GRATES/SOLID COVER SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05, WITH THE EXCEPTION OF THE BRONZE GRATE. 2 - FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05. 3 - DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212 FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL), N-12 HP, & PVC SEWER. 4 - DIMENSIONS ARE FOR REFERENCE ONLY. ACTUAL DIMENSIONS MAY VARY. 5 - DIMENSIONS ARE IN INCHES 6 - SEE DRAWING NO. 7001-110-275 FOR ADS N-12 & HANCOR DUAL WALL BELL INFORMATION & DRAWING NO. 7001-110-364 FOR N-12 HP BELL INFORMATION. (B) THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I OR CLASS II MATERIAL AS DEFINED IN ASTM D2321. BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321. ® ©2013 NYLOPLAST 18" MIN WIDTH GUIDELINE 8" MIN THICKNESS GUIDELINE (1, 2) INTEGRATED DUCTILE IRON FRAME & GRATE TO MATCH BASIN O.D. TRAFFIC LOADS: CONCRETE SLAB DIMENSIONS ARE FOR GUIDELINE PURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE DESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS, TRAFFIC LOADING, & OTHER APPLICABLE DESIGN FACTORS. SEE DRAWING NO. 7001-110-111 FOR NON TRAFFIC INSTALLATION. CD1.2 GRADING & DRAINAGE DETAILS Date Drawn By Checked By Project Number Sheet of Issue Revisions OWNER'S REPRESENTATIVE Colorado State University Facilities Management 251 Edison Drive Fort Collins, CO, 80523-6030 970.491.0080 - Phone 970.491.7572 - Fax CIVIL ENGINEER JVA Consulting Engineers 25 Old Town Square, Ste. 200 Fort Collins, CO 80524 303.444.1951 LANDSCAPE ARCHITECT Design Workshop 1390 Lawrence St. Ste. 100 Denver, CO, 80204 303.623.2616 STRUCTURAL ENGINEER JVA Consulting Engineers 1319 Spruce St. Boulder, CO, 80302 303.444.1951 MECHANICAL / ELECTRICAL / PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner Denver . Colorado . 80204 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner Denver . Colorado . 80204 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER C1.6 DETAILED GRADING PLAN - SOUTHEAST CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER C1.5 DETAILED GRADING PLAN - SOUTHWEST CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER C1.4 DETAILED GRADING PLAN - EAST CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER C1.3 DETAILED GRADING PLAN - WEST CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER C1.2 DETAILED GRADING PLAN - NORTHEAST CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER C1.1 DETAILED GRADING PLAN - NORTHWEST CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner PLUMBING ENGINEERING ME Engineers 14143 Denver West Parkway, Ste. 300 Golden, CO, 80401 303.421.6655 ELECTRICAL Gregory Electric 3317 North Lincoln Ave Loveland, CO, 80538 970-669-7609 MECHANICAL CONTRACTOR US Engineering Co 1100 W. 120th Ave #900 Westminster, CO, 80234 303.964.8060 ENERGY / ENVIRONMENTAL Ambient Energy 130 W. 5th Ave Denver, CO, 80204 303.278.1532 SPECIFICATIONS Specifications for Architects, Inc. 6560 West Alamo Drive Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER C0.2 CITY OF FORT COLLINS NOTES CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER C0.1 NOTES, LEGEND, & ABBREVIATIONS CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner Littleton, CO, 80123 303.927.8362 1301 Wazee . Suite 100 Denver . Colorado . 80204 303 . 623 . 7323 303 . 623 . 2836 Fax NOT FOR CONSTRUCTION 797 Ventura St. Aurora. Colorado. 80011 303 . 363 . 7101 303 . 363 . 9251 Fax Owner Project Number BENNETT WAGNER GRODY ARCHITECTS 10/8/2015 12:22:27 PM DECEMBER 11, 2015 14-023 151 W. Lake Street Fort Collins, CO 80524 100% UTILITY PLAN SET KRB KAT 15042.00 CSU HEALTH AND MEDICAL CENTER C0.0 COVER SHEET CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Date Date Date Date Date Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL Parks and Recreation Traffic Engineer Stormwater Utility Water & Wastewater Utility City Engineer CHECKED BY: APPROVED: Date Environmental Planner Pre reservveeExisting 20’Alley R.O.W. Bike ke Cage 24’ 4’ 24’ 4’ 30’ 18’ 88.5’ Medica cal Ce Center 106 Pa Parkingg Space ces Wa Wayyfindingg Sign Maintain Exist stingg Acc cce cess Limits of Wo Work ExistingWWaalk Dro rop-Off EV Charg rging 8S g g Station: 8 Stalls TW 98.5 BW 97.0 TW 99.5 BW 98.0 TW 98.5 BW 97.0 TW 95.3 BW 93.7 TW 99.5 BW 98.00 TW 98.5 66’ 8’ 7’ 10’ 10’ 10’ Detention Are rea Landmark Preservation Commission Presentation Medical Center Site Plan with Existing Structures 0’ 10’ 20’ 40’ NORTH 1405 S. College Ave. 1407 S. College Ave. 1413 S. College Ave. 1415 S. College Ave. 1417 S. College Ave. 1419 S. College Ave. 1421 S. College Ave. 1435 S. College Ave. 117 W. Lake St. 119 W. Lake St. 121 W. Lake St. 131 W. Lake St. 133 W. Lake St. 137 W. Lake St. 120 W. Prospect Rd. 116 W. Prospect Rd. September 9, 2015