Loading...
HomeMy WebLinkAboutTHE GREEN SOLUTION - PDP/FDP - FDP150045 - SUBMITTAL DOCUMENTS - ROUND 3 - SITE, LANDSCAPE & ELEVATIONS PLANSCOVER SHEET THE GREEN SOLUTION 810 N COLLEGE AVENUE FORT COLLINS, CO TGSFCCO01  03/17/16 MAM JAR DJM Plotted: 4/27/2016 5:56 PM Dwg Name: P:\Tgsfcco01\dwg\Eng\Final Drawings\Plan Set\Cover Sheet.dwg Updated By: mmcguire FINAL DEVELOPMENT PLAN FOR THE GREEN SOLUTION 810 N COLLEGE AVE LOT 1, TGS COLLEGE AVENUE SUBDIVISION A PART OF SECTION 1, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE SIXTH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO VICINITY MAP SITE PROJ. MGR.: DRAWN BY: DATE: OF SHEET PROJ. ASSOC.: DATE REVISIONS DRAWN BY c 2016 MANHARD CONSULTING, LTD. ALL RIGHTS RESERVED TM 1 12/15/15 1ST SUBMITTAL TO CITY JAR 2 02/03/15 2ND SUBMITTAL TO CITY JAR 3 04/28/15 3RD SUBMITTAL TO CITY JAR S PROPERTY LINE EASEMENT CENTERLINE SETBACK BUILDING EXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER PROPOSED SPILL CURB AND GUTTER PROPOSED SIDEWALK SAWCUT PROPOSED STORM DRAIN EXISTING STORM DRAIN PROPOSED CATCH BASIN PROPOSED DRAIN MANHOLE PROPOSED SANITARY SEWER EXISTING SANITARY SEWER EXISTING WATER MAIN EXISTING GAS LINE EXISTING ELECTRICAL EXISTING TELECOM EXISTING SEWER MANHOLE EXISTING FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED WATER VALVE PROPOSED WATER METER PROPOSED WATER PROPOSED SEWER CLEANOUT PROPOSED FDC EXISTING OVERHEAD ELECTRIC PROPOSED MAJOR CONTOUR EXISTING BUILDING TBA: 2330 S.F. BUILDING HEIGHT: 15 FT. EXISTING BOWLING ALLEY EXISTING LIQUOR STORE NORTH COLLEGE AVENUE EXISTING CAR SALES APPROXIMATE LIMITS OF BUILDING EXPANSION TBA: 2470 S.F. BUILDING HEIGHT: 17 FT. 9.00' (TYP) 8.00' (TYP) 8.00' (TYP) 6.00' 5.00' 5.00' 5.00' COMPACTOR ENCLOSURE (SEE ARCH PLANS) 5.00' 8.00' 23.00' COVERED BICYCLE RACKS (SEE ARCH PLANS) MAIN INGRESS/EGRESS TO NORTH COLLEGE AVENUE EX. 8' SIDEWALK 8.0' SIDEWALK 10.61' 40.13' EXISTING MONUMENT SIGN APN:9701300035 PROPOSED STEPS LANDSCAPE AREA LANDSCAPE AREA LANDSCAPE AREA LANDSCAPE AREA (SEE LANDSCAPE PLANS) 17.00' (TYP) N: 1460995.76 E: 3117769.43 N: 1460996.65 E: 3117677.59 15.0' UTILITY EASEMENT CHASE 91.85' (SEE ARCH PLANS) 28.05' LANDSCAPE KEY NEW DECIDUOUS TREE NEW SPECIMEN SHRUB NEW DECIDUOUS SHRUB NEW EVERGREEN SHRUB EXISTING TREE TO REMAIN EXISTING TREE TO BE REMOVED ROCK MULCH NEW ORNAMENTAL GRASS, WOOD MULCH NEW SOD EXISTING TURF PERENNIAL, OR GROUND COVER 1.5" WASHED RIVER ROCK OVER POROUS LANDSCAPE FABRIC TURF TYPE TALL FESCUE NATURAL COLOR SHREDDED CEDAR WITH NO FABRIC UNDERLAY 0'.0" 10'.0" 20'.0" 30'.0" WOOD MULCH SIGHT TRIANGLE ROCK MULCH ROCK MULCH ROCK MULCH EXISTING TO WOOD MULCH SAN. SEWER EXISTING NEW BOWLING ALLEY LIQUOR STORE ZALLI MOTORS CAR SALES REMAIN SOD NEW SOD Revisions: Plan Date: Sheet Number: PLAN LANDSCAPE NATURE'S DESIGN Licensed Landscape Architecture ASSOCIATES LLC 810 North College Avenue, Fort Collins, Colorado The Green Solution LANDSCAPE PLAN DESIGN STATEMENT PLANT LIST NUMBER OF TREES ON SITE REQUIREMENT: 0-19 % OF ANY ONE SPECIES 50% PROVIDED: 7 43% TREE DIVERSITY CHART TREE AND SHRUB PLACEMENT NOTE: THERE MUST BE A 10 FT. SEPARATION BETWEEN ALL NEW TREES AND EXISTING 4" CAL. OAK TO REMAIN EXISTING 4" CAL. CRABAPPLE TO REMAIN 0'.0" 10'.0" 20'.0" 30'.0" EXISTING SIBERIAN ELM 2 STEMS: 8" AND 6" CAL. FAIR CONDITION-WILD ORIGIN-NO MITIGATION EXISTING SIBERIAN ELM 3 STEMS: 7", 8" AND 9" CAL. POOR CONDITION-WILD ORIGIN-NO MITIGATION REMOVE: REMOVE: EXISTING SIBERIAN ELM 1 STEM: 3" CAL. POOR CONDITION-WILD ORIGIN-NO MITIGATION REMOVE: EXISTING BOX ELDER 3 STEMS: 4", 5", AND 6" CAL. POOR CONDITION-WILD ORIGIN-NO MITIGATION REMOVE: EXISTING BOX ELDER 1 STEM: 10" CAL. LIVE CROWN: MITIGATE (UPSIZE 1 PROPOSED TREE REMOVE: TO 3"BB-SEE SHEET L-1) REMOVAL OF EXISTING TREES WITH OWNER OF ADJACENT PROPERTY COORDINATE REMOVE STUMP EXISTING BOX ELDER 2 STEMS: 3" AND 4" CAL. POOR CONDITION-WILD ORIGIN-NO MITIGATION REMOVE: NOTE: EXISTING SIBERIAN ELM 3 STEMS: 5", 7" AND 7" CAL. POOR CONDITION-WILD ORIGIN-NO MITIGATION REMOVE: LIQUOR STORE (ADJACENT PROPERTY OWNER MUST GRANT APPROVAL FOR THE REMOVAL OF THIS OFF- SITE TREE. Revisions: Plan Date: Sheet Number: PLAN LANDSCAPE FIN. FLR. 100'-0" (4968.9' NAVD-88) NEW STUCCO ON EXISTING T1-11 NEW BRICK VENEER WATERTABLE EXISTING METAL MANSARD ROOF ADDITION PARAPET WALL BEYOND NEW BIKE RACKS NEW FLOOD DOORS IN EXISTING FACADE,PAINT P1 EXISTING WOOD FRAMED WINDOWS REMOVE LAP SIDING & INSTALL STUCCO EXISTING BRICK VENEER (REMOVE & REPLACE) EXISTING METAL MANSARD ROOF 3/16" = 1' - 0" 3 WEST ELEVATION A2.1 EXISTING ROOF “  EXTEND EXIST. PARAPET WALL UP NEW PARAPET “  EXTERIOR MATERIALS & COLORS: BRICK VENEER: ALL NEW BRICK TO MATCH EXISTING STUCCO: ALL NEW STUCCO TO MATCH EXISTING BUILDING PRIMARY FIELD COLOR (P1-BEIGE) TRIM & GUTTERS/D.S.: P2-PAINT GREEN (MATCH EXISTING TRIM COLOR) METAL ROOFING: NEW STANDING SEAM METAL ROOF TO MATCH EXISTING COLOR & PROFILE DOORS: HOLLOW METAL, COLOR TO MATCH EXISTING DOORS, (P1-BEIGE) STUCCO EXISTING BUILDING FRONTAGE EXISTING BRICK VENEER EXISTING METAL ROOF (GREEN) EXISTING TRIM (GREEN) EXISTING LAP SIDING, CHANGE TO STUCCO (BEIGE) N.T.S. EXISTING BUILDING FRONTAGE EXISTING WOOD COLUMN DEMO (E) VENTS, PATCH OPENING 810 EXISTING GUTTER RFPE (4969.77' NAVD-88) ELEV. 100'-10" INFILL OPENING W/ STUCCO & BRICK BUILDING ADDRESS NUMBERS (6" Min.) BFE ELEV. 97'-10"(4967.77' NAVD-88) KNOX BOX FIN. FLR. NORTH COLLEGE AVENUE 1" = 10' - 0" north 1 LIGHTING PLAN E1 0' 5' 10' 15' WALL MTD. LIGHT FIXTURES - DOWNCAST A A A A A B B B B B B B B B B RECESSED DOWN LIGHTS IN SOFFIT SA architecture EXTERIOR LIGHTING THE GREEN SOLUTION 810 N. COLLEGE AVENUE, FORT COLLINS, COLORADO Ph: (303) 443-1585 Boulder, Colorado 80303 5375 Pennsylvania Ave. PDP A Recessed downlights in soffit. B Wall mounted light fixtures. Note: All exterior fixtures to be full cut-off and downcast. 6 OF 6 100'-0" WALL MOUNTED LIGHT FIXTURES. NOTE: ALL SITE LIGHTING SHALL BE FULL CUT-OFF & DOWN CAST. EXISTING ROOF BEYOND STUCCO, PAINT P1 “  ADDITION ROOF 117'-0" EXISTING BUILDING PROPOSED ADDITION STUCCO RTU UNIT SCREEN BEYOND 3/16" = 1' - 0" 4 SOUTH ELEVATION A2.1 NEW STUCCO ON EXIST. CMU NEW BRICK VENEER EXISTING METAL MANSARD ROOF EXTEND EXISTING PARAPET WALL UP EXISTING ROOF “  RTU UNIT SCREEN SCUPPER & D.S. CONTROL JOINTS, TYP. CONC. SPLASHBLOCK, TYPICAL CONC. FOUNDATION WALL ROOF BEYOND ELEV. 100'-10" BFE ELEV. 97'-10" RFPE (4969.77' NAVD-88) TRASH ENCLOSURE TRASH ENCLOUSRE 4" CORNICE OVERHANG, RE: 1/A3.1 3/16" = 1' - 0" 2 EAST ELEVATION A2.1 FILL EXISTING WINDOW OPENING WITH C.M.U. EXISTING ROOF & GUTTER EXISTING D.S. PARGE COAT OVER EXISTING CMU FIN. FLR. 100'-0" EXISTING METAL MANSARD ROOF BEYOND TRASH ENCLOUSRE ADDITION EXISTING FLUSH HOLLOW METAL FLOOD DOOR, PAINT P1 ADDITION ROOF 117'-0" EXISTING ROOF “  11 2‘67((/3,(5$,/3$,173 NEW BRICK VENEER ON EXISTING CMU ELEV. 100'-10" BFE ELEV. 97'-10" RFPE (4969.77' NAVD-88) 3'-0" 9'-8" 4'-4" 4" CORNICE OVERHANG, RE: 1/A3.1 TRASH ENCLOSURE FIN. FLR. 100'-0" WALL MOUNTED LIGHT FIXTURES. NOTE: ALL SITE LIGHTING SHALL BE FULL CUT-OFF & DOWN CAST. BRICK VENEER PILASTER, MATCH EXISTING BRICK STUCCO, PAINT P1 EXISTING PARGE COATED CMU EXISTING METAL MANSARD ROOF EXISTING WINDOW STUCCO EXISTING BRICK VENEER EXISTING ROOF “  ADDITION ROOF 117'-0" WIRE MESH TRELLIS, BLACK POWDER COAT BRICK VENEER WATERTABLE SOLDIER COURSE NEW BRICK VENEER WATERTABLE ON EXISTING PARGE COAT PROPOSED ADDITION EXISTING BUILDING STUCCO RTU UNIT SCREEN BEYOND 3/16" = 1' - 0" 1 NORTH ELEVATION A2.1 “  “  FLUSH HOLLOW METAL FLOOD DOOR PAINT P1 FLUSH HOLLOW METAL MAN DOOR PAINT P1 STEEL ENCLOSURE GATES, PAINT P1 TRASH ENCLOUSRE ROOF BEYOND C.J. RE: 4/A3.3 TYP. ELEV. 100'-10" BFE ELEV. 97'-10" RFPE (4969.77' NAVD-88) 4'-4" 1'-6" CORNICE OVERHANG, RE: 1/A3.1 SOLDIER COURSE EXTERIOR ELEVATIONS Ph: (303) 443-1585 SA architecture Boulder, Colorado 80303 5375 Pennsylvania Ave. Sickbert & Associates PDP 5 OF 6 THE GREEN SOLUTION 810 N. COLLEGE AVENUE, FORT COLLINS, COLORADO NATURE'S DESIGN Licensed Landscape Architecture ASSOCIATES LLC 810 North College Avenue, Fort Collins, Colorado The Green Solution EXISTING TREE PLAN HYDROZONE MAP ANNUAL WATER BUDGET LANDSCAPE NOTES ALL WATER AND SEWER MAINS. THERE MUST BE A 6 FT. SEPARATION BETWEEN ALL NEW TREES AND ALL WATER AND SEWER SERVICE LINES THERE MUST BE A 4 FT. SEPARATION BETWEEN ALL NEW SHRUBS AND ALL WATER AND SEWER MAINS AND SERVICES. (SEE ARCH PLANS) PROPOSED CONCRETE WALK PROPOSED ASPHALT PROPOSED ASPHALT PAINTED WHITE PARKING STRIPE (TYP) SAWCUT LINE BIORETENTION FACILITY PROPOSED CURB FEMA 100-YEAR POUDRE RIVER FLOODPLAIN ZONE AE N: 1460985.16 E: 3117786.80 N: 1461060.15 E: 3117787.27 N: 1461061.26 E: 3117609.81 N: 1460986.26 E: 3117609.34 R2.00' R2.00' R2.00' 17.44' 10.50' 10.81' SAWCUT LINE SAWCUT LINE 0 SCALE: 1"=10' 5 10 20 SITE PLAN THE GREEN SOLUTION 810 N COLLEGE AVENUE FORT COLLINS, CO TGSFCCO01  03/17/16  JAR DJM Plotted: 4/27/2016 5:57 PM Dwg Name: P:\Tgsfcco01\dwg\Eng\Final Drawings\Plan Set\Site Plan.dwg Updated By: JRentz SITE DATA EXISTING PROPOSED ZONING SERVICE COMMERCIAL DISTRICT SERVICE COMMERCIAL DISTRICT LAND USE MEDICAL MARIJUANA STORE RETAIL MARIJUANA STORE LOT SIZE 13310 S.F. 13310 S.F. ACREAGE 0.305 GROSS 0.305 GROSS TOTAL FLOOR AREA 2330 S.F. 4800 S.F. RATIO 0.18 0.36 BUILDING HEIGHT 15'-0" 17'-0" PARKING SPACES 13 10 BIKE PARKING 0 4 PROPOSED COVERAGE SQUARE FOOTAGE PERCENTAGE LOT SIZE 13310 100.00 BUILDING 4800 36.06 DRIVEWAY/ PARKING 2370 17.81 PUBLIC R.O.W. 0 0.00 LANDSCAPE 4390 32.98 ACTIVE RECREATIONAL USE 0 0.00 PROJ. MGR.: DRAWN BY: DATE: OF SHEET PROJ. ASSOC.: DATE REVISIONS DRAWN BY c 2016 MANHARD CONSULTING, LTD. ALL RIGHTS RESERVED TM 1 12/15/15 1ST SUBMITTAL TO CITY JAR 2 02/03/15 2ND SUBMITTAL TO CITY JAR 3 04/28/15 3RD SUBMITTAL TO CITY JAR PROJECT DEVELOPMENT PLAN FOR THE GREEN SOLUTION 810 N COLLEGE AVE LOT 1, TGS COLLEGE AVENUE SUBDIVISION A PART OF SECTION 1, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE SIXTH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO 1. SIDEWALK WITHIN THIS PROJECT SHALL BE 5' WIDE CONCRETE UNLESS OTHERWISE NOTED. 2. PARKING LOT DIMENSIONS ARE TO THE FLOWLINE UNLESS OTHERWISE NOTED. 3. TYPICAL PARKING STALL DIMENSION SHOWN ON THIS PLAN IS 9' X 17' 4. PARKING LOT CURB RADII ARE 5' AT FLOWLINE UNLESS OTHERWISE NOTED. 5. SEE ARCH PLANS FOR EXACT BUILDING DIMENSIONS, LOCATIONS OF DOORS, AND BUILDING LIGHTING LOCATIONS. NOTES PROPOSED MINOR CONTOUR EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED SIGN EXISTING SIGN PARKING COUNT SYMBOL ADJ ADJUST ARCH ARCHITECT BOP BOTTOM OF PIPE B/W BACK OF WALK BM BENCHMARK B/O BY OTHERS BW BOTTOM OF WALL CB CATCH BASIN CL CENTERLINE C.O.F. CITY OF FORT COLLINS CONC CONCRETE CY CUBIC YARD DIA DIAMETER DIP DUCTILE IRON PIPE E ELECTRIC ELEV ELEVATION EP EDGE OF PAVEMENT ESMT EASEMENT EX EXISTING FDC FIRE DEPARTMENT CONNECTION FG FINISHED GRADE FF FINISHED FLOOR FFE FINISH FLOOR ELEVATION FES FLARED END SECTION FL FLOW LINE/ FIRE LANE G GROUND G/F GRADE AT FOUNDATION G/S GARAGE SLAB GW GUY WIRE HP HIGH POINT HYD HYDRANT INL INLET INV INVERT LP LOW POINT ME MATCH EXISTING MAX MAXIMUM MH MANHOLE MIN MINIMUM PA PUBLIC ACCESS PL PROPERTY LINE PP POWER POLE PROP PROPOSED PVC POLYVINYL CHLORIDE PIPE P PAVEMENT R RADIUS ROW RIGHT-OF-WAY RCP REINFORCED CONCRETE PIPE SAN SANITARY SEWER SF SQUARE FOOT SMH SANITARY MANHOLE ST STORM SEWER SW SIDEWALK SY SQUARE YARDS TB THRUST BLOCK TBR TO BE REMOVED T TELEPHONE TC TOP OF CURB TF TOP OF FOUNDATION TOP TOP OF PIPE TW TOP OF WALL TEMP TEMPORARY U UTILITY WM WATER MAIN WSE WATER SURFACE ELEVATION LEGEND ABBREVIATIONS 1. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS M TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS. 2. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS. 3. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION. 4. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 5. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. 6. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY. 7. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM. 8. ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED. 9. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSIBLE PARKING SPACES. ACCESSIBLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE. NOTES: THE GROW SHOP, LLC PO BOX 1428 FORT COLLINS, CO 80522 CONTACT: JOE DICE MANHARD CONSULTING LTD 8008 EAST ARAPAHOE COURT SUITE 110 CENTENNIAL, CO 80112 CONTACT: DANIEL MADRUGA PE ENGINEER: OWNER/DEVELOPER: SICKBERT & ASSOCIATES 5375 PENNSYLVANIA AVENUE BOULDER, CO 80303 CONTACT: MIKE SICKBERT ARCHITECT: FLOOD PLAIN ENGINEER HIGH POINT ENGINEERING PO BOX 150894 LAKEWOOD, CO 802015 CONTACT: JOHN TOMPKINS LANDSCAPE ARCHITECT NATURE'S DESIGN ASSOCIATES, LLC 15674 INDIANA GULCH ROAD JAMESTOWN, CO 80455 CONTACT: BECKY MARTINEK APPLICANT/TENANT THE GREEN SOLUTION, LLC 700 17TH STREET, SUITE 2200 DENVER, CO 80202 CONTACT: KYLE SPEIDELL PROJECT DATUM: NAVD88 SOURCE BENCHMARKS: 1. CITY OF FORT COLLINS BM 1-00 2" ALUMINUM CAP ON A CATCH BASIN AT THE SOUTHEAST CORNER OF VINE DRIVE AND COLLEGE AVENUE. ELEVATION = 4968.74 2. CITY OF FORT COLLINS BENCHMARK 43-97 2" ALUMINUM CAP LOCATED ON THE SOUTH END OF THE WEST HEADWALL OF THE LAKE CANAL BRIDGE AT NORTH LEMAY AVENUE, 200 FEET SOUTH OF THE INTERSECTION OF LEMAY AVENUE AND CONIFER STREET. ELEVATION = 4960.11 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED. NGVD29 UNADJUSTED = NAVD88 - 3.17'. BENCHMARKS OWNER'S ACKNOWLEDGMENT THE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT I/WE ARE THE LAWFUL OWNERS OF THE REAL PROPERTY DESCRIBED ON THIS SITE PLAN AND DO HEREBY CERTIFY THAT I/WE ACCEPT THE CONDITIONS AND RESTRICTIONS SET FORTH ON SAID SITE PLAN. OWNER (SIGNED) DATE THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS ________ DAY OF _____________ 20_____ A.D. BY (PRINT NAME) AS ____________________________________ MY COMMISSION EXPIRES:_______________ WITNESS MY HAND AND OFFICAL SEAL. NOTARY PUBLIC ADDRESS PLANNING CERTIFICATE APPROVED BYT THE DIRECTOR OF PLANNING OF THE CITY OF FORT COLLINS, COLORADO ON THIS ________ DAY OF _____________ 20_____ A.D. BY DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES SHEET INDEX COVER SHEET 1 OF 6 SITE PLAN 2 OF 6 LANDSCAPE PLAN (L-1) 3 OF 6 LANDSCAPE PLAN (L-2) 4 OF 6 BUILDING ELEVATIONS (A2.1) 5 OF 6 LIGHTING PLAN (E1) 6 OF 6