HomeMy WebLinkAboutRIGDEN FARM FILING NINETEEN - PDP/FDP - FDP150035 - PLANS - UTILITY PLANSUTILITY CONTACTS: City of Fort Collins Fort Collins, Colorado 80522 WATER/WASTEWATER Shane Boyle Ph. 970.221.6700 700 Wood Street TELEPHONE SERVICE Century Link (Qwest) 3351 Eastbrook Drive Fort Collins, Colorado 80525 Contact: Bill Johnson NATURAL GAS Xcel Energy 1901 E. Horsetooth Road Contact: Stephanie Rich Fort Collins, Colorado 80525 STORMWATER Wes Lamarque Ph. 970.416.2418 LIGHT & POWER Rob Irish Ph. 970.221.6700 Ph. 970.225.7828 Ph. 970.377.6401 vicinity map Scale: 1" = 500' Sheet No. Description of Sheets INDEX OF SHEETS COVER SHEET GENERAL NOTES HORIZONTAL CONTROL PLAN UTILITY PLAN GRADING PLAN DRAINAGE & EROSION CONTROL PLAN DETAILS 1 2 3 4 5 6 7 - 8 ........................................... ........................................... ........................................... ........................................... ........................................... ........................................... ........................................... Utility Plans For RIDGEN FARM FILING NINETEEN Located In The East Half Of Section 29, T-7-N, R-68-W Of The 6th PM City Of Fort Collins, Larimer County, Colorado FEBRUARY 2016 PROPOSED STREET LIGHT PROPOSED STORM SEWER MANHOLE EXISTING SANITARY SEWER MAIN PROPOSED TELEPHONE LINE EXISTING GAS ³ ´ ³´ ³ ´ ³ ´ ³ ´ PREPARED FOR PROJ. NO. DATE: SCALE (H): SCALE (V): CHECKED BY: DESIGNED BY: PROJECT NAME RIGDEN FARM FILING NINETEEN LOTS M8 & M9 GENERAL NOTES 2/26/16 N/A N/A SB RA 1233-133-00 2 of 8 SCHUMAN COMPANIES, INC. 605 S. COLLEGE AVE, SUITE 100 FORT COLLINS, COLORADO 80524 PHONE: 970.219.1493 LOT M8 LOT M9 TRACT AS (OPEN SPACE & DRAINAGE ESMT) TRACT BD (OPEN SPACE & UTILITY ESMT) LOT 319 LOT 232 BLOCK 1 LOT 1 BLOCK 1 LOT 2 BLOCK 1 LOT 3 BLOCK 2 LOT 1 BLOCK 2 LOT 2 BLOCK 2 LOT 3 PREPARED FOR PROJ. NO. DATE: SCALE (H): SCALE (V): CHECKED BY: DESIGNED BY: PROJECT NAME RIGDEN FARM FILING NINETEEN LOTS M8 & M9 HORIZONTAL CONTROL PLAN 2/26/16 1"=10' N/A SB RA 1233-133-00 3 of 8 SCHUMAN COMPANIES, INC. 605 S. COLLEGE AVE, SUITE 100 FORT COLLINS, COLORADO 80524 PHONE: 970.219.1493 0 SCALE: 1" = 10' 10 5 10 20 LEGEND PROPOSED AC PAVEMENT PROPOSED CONCRETE WALK NOTES: 1. ALL SIDEWALKS ON SITE SHALL BE 4" THICK. ALL SIDEWALKS WITHIN THE RIGHT-OF-WAY SHALL BE 6" THICK. 2. REFER TO THE GEOTECHNICAL REPORT FOR ADDITIONAL PAVEMENT DESIGN RECOMMENDATIONS. DUAL SIDEWALK CHASE NTS LOT M8 LOT M9 LOT 319 LOT 232 FF=99.93 GFF=98.60 BFF=90.09 FF=98.93 GFF=97.60 BFF=89.09 FF=97.93 GFF=96.60 BFF=88.09 FF=96.23 GFF=94.90 BFF=85.39 FF=95.73 GFF=94.40 BFF=86.89 FF=96.23 GFF=94.90 BFF=85.39 TRACT AS (OPEN SPACE & DRAINAGE ESMT) TRACT BD (OPEN SPACE & UTILITY ESMT) BLOCK 1 LOT 1 BLOCK 1 LOT 2 BLOCK 1 LOT 3 BLOCK 2 LOT 1 BLOCK 2 LOT 2 BLOCK 2 LOT 3 PREPARED FOR PROJ. NO. DATE: SCALE (H): SCALE (V): CHECKED BY: DESIGNED BY: PROJECT NAME RIGDEN FARM FILING NINETEEN LOTS M8 & M9 UTILITY PLAN 2/26/16 1"=10' N/A SB RA 1233-133-00 4 of 8 SCHUMAN COMPANIES, INC. 605 S. COLLEGE AVE, SUITE 100 FORT COLLINS, COLORADO 80524 PHONE: 970.219.1493 NOTES: 1. SANITARY SEWER INSTALLATIONS SHALL CONFORM FF=99.93 GFF=98.60 BFF=90.09 FF=98.93 GFF=97.60 BFF=89.09 FF=97.93 GFF=96.60 BFF=88.09 FF=96.23 GFF=94.90 BFF=85.39 FF=95.73 GFF=94.40 BFF=86.89 FF=96.23 GFF=94.90 BFF=85.39 LOT M8 LOT M9 LOT 319 LOT 232 TRACT AS (OPEN SPACE & DRAINAGE ESMT) TRACT BD (OPEN SPACE & UTILITY ESMT) A A PREPARED FOR PROJ. NO. DATE: SCALE (H): SCALE (V): CHECKED BY: DESIGNED BY: PROJECT NAME RIGDEN FARM FILING NINETEEN LOTS M8 & M9 GRADING PLAN 2/26/16 1"=10' N/A SB RA 1233-133-00 5 of 8 SCHUMAN COMPANIES, INC. 605 S. COLLEGE AVE, SUITE 100 FORT COLLINS, COLORADO 80524 PHONE: 970.219.1493 0 SCALE: 1" = 10' 10 5 10 20 NOTES: 1. ONSITE IMPROVEMENTS WILL BE PRIVATELY OWNED AND MAINTAINED. 2. ALL EARTHWORK AND PAVEMENT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT FOR THE SITE AND LCUASS AS APPLICABLE. 3. ALL CATCH SLOPES SHALL BE A MAXIMUM OF 4:1 UNLESS FF=99.93 GFF=98.60 BFF=90.09 FF=98.93 GFF=97.60 BFF=89.09 FF=97.93 GFF=96.60 BFF=88.09 FF=96.23 GFF=94.90 BFF=85.39 FF=95.73 GFF=94.40 BFF=86.89 FF=96.23 GFF=94.90 BFF=85.39 LOT M8 LOT M9 TRACT AS TRACT BD LOT 319 LOT 232 POND 269 PREPARED FOR PROJ. NO. DATE: SCALE (H): SCALE (V): CHECKED BY: DESIGNED BY: PROJECT NAME RIGDEN FARM FILING NINETEEN LOTS M8 & M9 DRAINAGE & EROSION CONTROL PLAN 2/26/16 1"=20' N/A SB RA 1233-133-00 6 of 8 SCHUMAN COMPANIES, INC. 605 S. COLLEGE AVE, SUITE 100 FORT COLLINS, COLORADO 80524 PHONE: 970.219.1493 0 SCALE: 1" = 20' 20 10 20 40 LEGEND BASIN COEFFICIENT (100-YR) BASIN DESIGNATION BASIN AREA DESIGN POINT DRAINAGE FLOW ARROW DRAINAGE BASIN BOUNDARY SILT FENCE INLET PROTECTION PREPARED FOR PROJ. NO. DATE: SCALE (H): SCALE (V): CHECKED BY: DESIGNED BY: PROJECT NAME RIGDEN FARM FILING NINETEEN LOTS M8 & M9 DETAILS 2/26/16 N/A N/A SB RA 1233-133-00 7 of 8 SCHUMAN COMPANIES, INC. 605 S. COLLEGE AVE, SUITE 100 FORT COLLINS, COLORADO 80524 PHONE: 970.219.1493 TRAFFIC BEARING CLEANOUT NOT TO SCALE PREPARED FOR PROJ. NO. DATE: SCALE (H): SCALE (V): CHECKED BY: DESIGNED BY: PROJECT NAME RIGDEN FARM FILING NINETEEN LOTS M8 & M9 DETAILS 2/26/16 N/A N/A SB RA 1233-133-00 8 of 8 SCHUMAN COMPANIES, INC. 605 S. COLLEGE AVE, SUITE 100 FORT COLLINS, COLORADO 80524 PHONE: 970.219.1493 CONSTRUCTION ENTRANCE W/ VEHICLE TRACKING CONTROL GRAVEL BAG CONCRETE WASHOUT AREA NOTES: 1. CONCRETE WASHOUT LOCATION TO BE DETERMINED IN THE FIELD. 2. CONTRACTOR TO ESTABLISH PERIMETER PROTECTION ALONG THE LIMITS OF DISTURBANCE TO LIMIT ACCESS TO THE ACTIVE CONSTRUCTION AREA. CONTRACTOR TO LIMIT SEDIMENT FROM ENTERING THE PUBLIC RIGHT OF WAY THROUGH THE USE OF A VEHICLE TRACKING PAD OR OTHER APPROVED METHOD. 3. THE DOWNSTREAM INLET ON THE SOUTH SIDE OF WILLIAM NEAL PARKWAY JUST WEST OF THE ZIEGLER INTERSECTION MAY BE REQUIRED TO RECEIVE INLET PROTECTION IF GRAVEL BAG AT PROPERTY LINE IS NOT ADEQUATELY MAINTAINED. 4. THE SITE CURRENTLY HAS EXISTING PERIMETER SILT FENCE INSTALLED. CONTRACTOR TO INSTALL NEW SILT FENCE AS NEEDED AND/OR MAINTAIN THE EXISTING SILT FENCE IN PLACE. OTHERWISE NOTED ON THE PLAN. 4. ALL SPOT SHOTS SHOWN ARE FINISH GRADE UNLESS OTHERWISE NOTED. 5. THE CONTRACTOR SHALL OBTAIN AND STAY CONTINUOUSLY IN COMPLIANCE WITH A STATE OF COLORADO STORMWATER DISCHARGE PERMIT ASSOCIATED WITH CONSTRUCTION ACTIVITIES. THIS INCLUDES THE CREATION AND MAINTENANCE OF A STORMWATER MANAGEMENT PLAN FOR THE SITE. 6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE AND APPROPRIATE EROSION CONTROL MEASURES IN THE CONSTRUCTION AREA. THE CONTRACTOR SHALL INSTALL TEMPORARY BMPS AS NEEDED TO CONTAIN SEDIMENT AND POLLUTANTS ON THE JOB SITE. 7. ALL EXTERIOR BUILDING GRADES SHALL BE 6" BELOW FINISHED FLOOR UNLESS OTHERWISE NOTED ON THE PLAN. 8. CONTRACTOR TO STAKE ADJACENT PROPERTY LINES PRIOR TO CONSTRUCTION TO PREVENT DAMAGE TO OFFSITE PROPERTY. 9. STEM WALL REQUIRED TO ALLOW GRADES HIGHER THAN PROPOSED FINISH FLOOR ELEVATION. 10. HANDRAILS REQUIRED AT STEPS. SEE ARCHITECTURAL PLAN FOR DETAIL. SECTION A-A TO THE CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS CURRENT AT THE DATE OF APPROVAL OF THE PLANS BY THE LOCAL ENGINEER. 2. LENGTH OF PIPE IS MEASURED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE. 3. ALL SANITARY SEWER PIPE SHALL BE PVC (SDR 35) UNLESS OTHERWISE NOTED ON THE PLAN. SEWER PIPE SHALL BE AS SPECIFIED BY THE CITY OF FORT COLLINS STANDARD PLANS AND SPECIFICATIONS. 4. ALL SANITARY SEWER CLEANOUTS LOCATED IN THE DRIVE AREA SHALL BE TRAFFIC RATED CLEANOUTS. 5. ALL SANITARY SEWER SERVICE SHALL BE 6" PVC AT A MINIMUM SLOPE OF 1% UNLESS OTHERWISE NOTED. 6. CONTRACTOR TO CONFIRM DEPTH OF EXISTING SANITARY SEWER STUB FOR EACH LOT. THE INVERT AT THE CONNECTION NOTED ON THE PLANS IS BASED ON AS BUILT INFORMATION OF THE MAIN LINE IN BRYCE DRIVE AND ASSUMED SERVICE CONFIGURATION. NOTIFY THE ENGINEER IF THE INVERT IN THE FIELD IS DIFFERENT THAN THE INVERT NOTED ON THE PLANS. 7. SITE CONTRACTOR SHALL TERMINATE UTILITY SERVICES 3 FEET FROM BUILDING UNLESS OTHERWISE NOTED. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT BUILDING CONNECTION LOCATIONS. 8. WATER CONSTRUCTION SHALL CONFORM TO THE CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS CURRENT AT THE DATE OF APPROVAL OF THE PLANS BY THE LOCAL ENGINEER. 9. WATER SERVICES SHALL BE TYPE K COPPER PIPE AS SPECIFIED BY THE CITY OF FORT COLLINS STANDARD PLANS AND SPECIFICATIONS. 10. ALL WATER SERVICES SHALL BE INSTALLED AT A MINIMUM OF 5-FEET BELOW FINISHED FLOOR ELEVATION. 11. CITY OF FORT COLLINS LIGHT & POWER (L&P) SHALL INSTALL PRIMARY LINE FROM CONNECTION POINT TO ELECTRIC VAULT, SECONDARY LINES FROM VAULT TO METER, AND BUILDING METER. CONTRACTOR SHALL COORDINATE WITH FORT COLLINS METER GROUP FOR METER LOCATION. CONTACT CITY OF FORT COLLINS LIGHT & POWER FOR THEIR CURRENT REQUIREMENTS. 12. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATION DETAILS OF GAS METERS, ELECTRIC METERS, AND TELEPHONE TERMINALS. 13. ALL DOWN SPOUTS SHALL DISCHARGE ON GRADE. DOWN SPOUTS DRAINING SOUTH SHALL DISCHARGE ON GRADE TO THE PERMEABLE PAVER SYSTEM. 0 SCALE: 1" = 10' 10 5 10 20 WATER METER TYPICAL LAYOUT SPLIT WATER METER DETAIL NOT TO SCALE EXISTING STORM SEWER EXISTING WATER MAIN EXISTING MANHOLE PROPOSED STORM INLET LEGEND PROPOSED CONCRETE PROPOSED MINOR CONTOUR PROPOSED SPOT ELEVATION EXISTING SPOT ELEVATION PROPOSED MAJOR CONTOUR EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR EXISTING UTILITY POLE EXISTING GUY WIRE PROPOSED GAS EXISTING ELECTRIC LINE PROPOSED ELECTRIC LINE EXISTING TELEPHONE LINE PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT EXISTING WATER VALVE PROPOSED SANITARY SEWER MANHOLE PROPOSED WATER VALVE EXISTING CONCRETE EXISTING FLOWLINE, CURB & GUTTER PROPOSED FLOWLINE, CURB & GUTTER PROPOSED FENCE LIMITS OF DEVELOPMENT (LOD) EXISTING OVERHEAD UTILITY EXISTING STORM SEWER INLET PROPOSED UTILITY POLE EXISTING STREET LIGHT PROPOSED SWALE PROPOSED DIRECTION OF OVERLAND FLOW PROPOSED EMERGENCY OVERFLOW ROUTE EXISTING FIBER OPTIC LINE PROPOSED HANDICAP RAMP EXISTING OVERHEAD ELECTRIC LINE EXISTING OVERHEAD TELEPHONE LINE PROPOSED OVERHEAD ELECTRIC LINE PROPOSED FIBER OPTIC LINE PROPOSED OVERHEAD TELEPHONE LINE EXISTING FENCE PROPOSED WATER SERVICE W/ PROPOSED SANITARY SEWER SERVICE CURB STOP AND METER PIT W/ CLEANOUT AD ALGEBRAIC DIFFERENCE AE ACCESS EASEMENT ARV AIR RELEASE VALVE BOV BLOW OFF VALVE BW BOTTOM OF WALL CL CENTERLINE CMP CORRUGATED METAL PIPE CO CLEAN OUT DE DRAINAGE EASEMENT E ELECTRIC EAE EMERGENCY ACCESS EASEMENT EG EXISTING GROUND EL ELEVATION EOA EDGE OF ASPHALT EX EXISTING ESMT EASEMENT F FIRE LINE FES FLARED END SECTION FF FINISHED FLOOR FG FINISHED GRADE FH FIRE HYDRANT FL FLOWLINE FO FIBER OPTIC G GAS GB GRADE BREAK GD GROUND GV GATE VALVE HDPE HIGH DENSITY POLYETHYLENE HP HIGH POINT IE IRRIGATION EASEMENT INV INVERT IRR IRRIGATION LF LINEAR FEET LP LOW POINT LT LEFT MH MANHOLE OHE OVERHEAD ELECTRIC OHT OVERHEAD TELEPHONE OHU OVERHEAD UTILITY PE PEDESTRIAN EASEMENT PC POINT OF CURVATURE PCR POINT OF CURB RETURN PI POINT OF INTERSECTION PT POINT OF TANGENCY PVC POLYVINYL CHLORIDE RCP REINFORCED CONCRETE PIPE RD ROOF DRAIN ROW RIGHT-OF-WAY RT RIGHT S SANITARY SEWER STA STATION SD STORM DRAIN PIPE SDMH STORM DRAIN MANHOLE SMH SANITARY SEWER MANHOLE T TELEPHONE TB THRUST BLOCK TBC TOP BACK OF CURB TCE TEMPORARY CONSTRUCTION EASEMENT TC TOP OF CONCRETE TF TOP OF FOUNDATION TW TOP OF WALL TYP TYPICAL UE UTILITY EASEMENT VB VALVE BOX VCP VITRIFIED CLAY PIPE VPC VERTICAL POINT OF CURVATURE VPI VERTICAL POINT OF INTERSECTION VPT VERTICAL POINT OF TANGENCY W WATERLINE ABBREVIATION LIST PROPOSED OVERHEAD UTILITY PROPOSED LIGHT POLES EXISTING CABLE TV PROPOSED CABLE TV EXISTING WOOD POST EXISTING METAL POST PHASE LINE INDEMNIFICATION STATEMENT: THESE PLANS HAVE BEEN REVIEWED BY THE LOCAL ENTITY FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BY THE REVIEWING DEPARTMENT, THE LOCAL ENTITY ENGINEER, OR THE LOCAL ENTITY FOR ACCURACY AND CORRECTNESS OF THE CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT QUANTITIES OF ITEMS ON THE PLANS ARE THE FINAL QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE LOCAL ENTITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE CONSTRUCTION PHASE. PREPARED FOR PROJ. NO. DATE: SCALE (H): SCALE (V): CHECKED BY: DESIGNED BY: PROJECT NAME RIGDEN FARM FILING NINETEEN COVER SHEET 2/26/16 N/A N/A SB RA 1233-133-00 1 of 8 SCHUMAN COMPANIES, INC. 605 S. COLLEGE AVE, SUITE 100 FORT COLLINS, COLORADO 80524 PHONE: 970.219.1493 ARCHITECT Rentfrow Design, LLC 205 Allen Street Fort Collins, CO 80525 Ph. 970.412.3400 Contact: Jon Rentfrow LANDSCAPE ARCHITECT The Birdsall Group 444 Mountain Avenue Berthoud, CO 80513 Ph. 970.532.5891 Contact: Cathy Mathis ENGINEER Interwest Consulting Group 1218 W. Ash, Suite A Windsor, Colorado 80550 Ph. 970.674.3300 Contact: Skylar Brower SURVEYOR King Surveyors, Inc. 650 East Garden Drive Windsor, Colorado 80550 Ph. 970.686.5011 Contact: Larry Pepek PROJECT DATUM: NAVD88 BENCHMARK #2-94 IN FORT COLLINS, EAST DRAKE AND ZIEGLER RD., APPROX. 110 FEET EAST OF SOUTH ENTRANCE TO WATER TREATMENT PLANT #2, ON TOP OF THE SECTION CORNER MONUMENT DATED 1989 IN RANGE BOX. ELEVATION: 49881.56 BENCHMARK #3-94 IN FORT COLLINS, EAST SIDE OF ZIEGLER RD. APPROXIMATELY 1/2 MILE NORTH OF HORSETOOTH RD., 250' NORTH OF INTERSECTION OF WILLIAM NEAL PARKWAY/CR 9 AND 25' WEST OF FENCE ON A CONCRETE HEADWALL. ELEVATION: 4890.97 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD 29 UNADJUSTED = NAVD88 BENCHMARK #2-94 - 3.18' BENCHMARK #3-94 - 3.19'