Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FOOTHILLS MALL REDEVELOPMENT, MULTI-FAMILY - FDP - FDP150048 - REPORTS - DRAINAGE REPORT
5285 McWhinney Blvd., Suite 160 TEL 303.237.2072 Loveland, CO 80538 FAX 303.237.2659 www.olssonassociates.com January 27, 2016 Stormwater Engineering City of Fort Collins 281 North College Avenue Fort Collins, CO 80524 RE: Addendum 3 Drainage Analysis for the Major Amendment to a Portion of Foothills Mall Redevelopment Planning Area 3 (Lots 3, 4, 5, and 6 of Foothills Mall Redevelopment) Dear Sir or Madam: Olsson has completed an analysis of the drainage design for Lot 3, 4, 5, and 6 of Foothills Mall Redevelopment to determine the changes from the original to the proposed design. The original design is defined within the following drainage report: Storm Water Management Plan for Foothills Redevelopment, prepared by R.A. Smith National, dated Revised December 5, 2013 (existing drainage report). The lots fall within Basin 25 of the Existing Drainage Report. The original basin’s imperviousness was compared to the imperviousness of the proposed design to determine if further analysis would be required. The original design’s overall composite percent imperviousness was determined to be 68 percent. The percent imperviousness of the proposed design was calculated to be 65 percent. Based on the calculations, a reduction of the developed runoff would be anticipated. See attached calculations and supporting material. Since the intended drainage patterns will remain the same, detailed analysis will not be required. In addition, the runoff for original design was intended to drain to sand filters and rain gardens within the Foothills Mall Redevelopment: Sand Filters SF-1.0, SF-2.0, and SF-4.0; and Rain Gardens RG-29 and RG-31. These drainage systems have been designed per the existing drainage report and are being constructed as part of the Foothills Redevelopment Planning Area 2 Final Plans. The rain garden and sand filter design’s assumed the contributing area was 90 percent imperviousness. Based on that assumption, additional analyses will not be required. Since rain garden RG-33 was being constructed as part of Foothills Redevelopment Planning Area 3 Final Plans, analysis of the rain garden was completed for the proposed design. Based on the analysis a rain garden will be provided in the northeast corner of Lot 3 meeting the original intent. Lastly, hydraulic calculations have been completed for the internal drainage system to show the internal system is adequate to convey the runoff from the 2-year and 100-year storm event. To determine the runoff to the system, sub-basins and runoff coefficients where determined base Addendum 3 Drainage Analysis for the Major Amendment to a Portion of Foothills Mall Redevelopment Planning Area 3 (Lots 3, 4, 5, and 6 of Foothills Mall Redevelopment) Page 2 on the layout and impervious services. To simplify the model, the time of concentration for all basins was assumed to be 5 minutes. Based on the calculations, the system will convey the majority of the sites runoff during the 2-year and 100-year storm event in pipe to the raingardens and sand filters. Areas of sheet flow will be conveyed by the existing and proposed grading. In the event Inlets are overtopped by the runoff, the runoff will be conveyed by the existing and proposed grading to the raingardens and sand filters. See attached calculations. The following calculations and supporting material are attached for your reference: • Exhibit A – Vicinity Map • Exhibit B – Existing Drainage Basins • Exhibit C – Percent Imperviousness • Exhibit D – Lot Map (Rain Garden Locations) • Exhibit E – Revised Rain Garden, RG-33 • Exhibit F – Revised Rain Garden, RG33, Calculations • Exhibit G – Sub-Basin Discharge and Inlet Sizing • Exhibit H – Inlet Capacities • Exhibit I – Pipe Hydraulic Calculations • Exhibit J – Sub-basin Map If you have any questions or need additional information, please contact me. Sincerely, Olsson Associates Daniel Hull, PE Senior Project Engineer Enclosures TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard Foothills Mall Multi-Family R Exhibit A Vicinity Map Map taken from Storm Water Management Plan for Foothills Redevelopment, prepared by R.A. Smith National, dated Revised December 5, 2013 Lot 3, 4, 5 and 6 TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard Foothills Mall Multi-Family Exhibit B R Existing Drainage Basins Lot 3, 4, 5, and 6 Map taken from Storm Water Management Plan for Foothills Redevelopment, prepared by R.A. Smith National, dated Revised December 5, 2013 TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard Foothills Mall Multi-Family Exhibit C R Lot Map LOT 3 LOT 4 LOT 5 SAND FILTER 2.0 SAND FILTER 4.0 RAIN GARDEN 29.0 RAIN GARDEN 31.0 RAIN GARDEN 33.0 LOT 6 SAND FILTER 1.0 TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard Foothills Mall Multi-Famliy Exhibit D R Percent Imperviousness Lot Area (SF) AREA (AC) Landscape Paved Roof Walks Porous Paving Percent Impervious 0% 100% 90% 90% 90% 3 170,929 3.92 47,519 47,007 58,191 18,212 0 68% 4 112,588 2.58 36,461 1,162 66,796 8,169 0 61% 5 101,716 2.34 15,199 1,782 68,600 16,135 0 77% 6 134,248 3.08 33,514 2,263 89,864 8,607 0 68% Total 519,481 8.84 132,693 52,214 283,451 51,123 0 68% Lot Area (SF) AREA (AC) Landscape Paved Roof Walks Porous Paving Percent Impervious 0% 100% 90% 90% 90% 3 170,929 3.92 60,271 44,931 42,897 3,831 18,999 61% 4 112,588 2.58 44,439 25,197 29,278 5,663 8,011 57% 5 101,716 2.34 26,054 29,121 32,548 4,580 9,413 70% 6 134,248 3.08 30,846 47,255 38,542 5,166 12,439 73% Total 519,481 8.84 161,610 146,504 143,265 19,240 48,862 65% Existing Design Proposed Design Imperviousness Imperviousness TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard R T T Foothills Mall Multi-Family Exhibit E Revised Rain Garden RG-33 Contributing Area 1.56 acres Rain Garden RG-33.0 Sheet 1 of 2 Designer: Company: Date: Project: Location: 1. Basin Storage Volume A) Effective Imperviousness of Tributary Area, Ia Ia = 68.0 % (100% if all paved and roofed areas upstream of rain garden) B) Tributary Area's Imperviousness Ratio (i = Ia/100) i = 0.680 C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time WQCV = 0.21 watershed inches (WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i) D) Contributing Watershed Area (including rain garden area) Area = 68,348 sq ft E) Water Quality Capture Volume (WQCV) Design Volume VWQCV = 1,213 cu ft Vol = (WQCV / 12) * Area F) For Watersheds Outside of the Denver Region, Depth of d6 = 0.00 in Average Runoff Producing Storm G) For Watersheds Outside of the Denver Region, VWQCV OTHER = 0.0 cu ft Water Quality Capture Volume (WQCV) Design Volume H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER = cu ft (Only if a different WQCV Design Volume is desired) 2. Basin Geometry A) WQCV Depth (12-inch maximum) DWQCV = 12 in B) Rain Garden Side Slopes (Z = 4 min., horiz. dist per unit vertical) Z = 4.00 ft / ft (Use "0" if rain garden has vertical walls) C) Mimimum Flat Surface Area AMin = 809 sq ft D) Actual Flat Surface Area AActual = 993 sq ft E) Area at Design Depth (Top Surface Area) ATop = 1692 sq ft F) Rain Garden Total Volume VT= 1,343 cu ft (VT= ((ATop + AActual) / 2) * Depth) 3. Growing Media 4. Underdrain System A) Are underdrains provided? B) Underdrain system orifice diameter for 12 hour drain time i) Distance From Lowest Elevation of the Storage y = 60.0 ft Volume to the Center of the Orifice ii) Volume to Drain in 12 Hours Vol12 = 1,213 cu ft iii) Orifice Diameter, 3/8" Minimum DO = 0.40 in Design Procedure Form: Rain Garden (RG) Daniel Hull Olsson Associates April 24, 2015 Major Amendment to a Portion of Foothills Mall Redevelopment Planning Area 3 Modified Rain Garden 33 Choose One Choose One 18" Rain Garden Growing Media Other (Explain): YES NO Rain Garden 33.0 Calcs.xlsm, RG 4/24/2015, 1:57 PM Exhibit F Modified Rain Garden, RG33 1of 2 Sheet 2 of 2 Designer: Company: Date: Project: Location: 5. Impermeable Geomembrane Liner and Geotextile Separator Fabric A) Is an impermeable liner provided due to proximity of structures or groundwater contamination? 6. Inlet / Outlet Control A) Inlet Control 7. Vegetation 8. Irrigation A) Will the rain garden be irrigated? Notes: Design Procedure Form: Rain Garden (RG) Daniel Hull Olsson Associates April 24, 2015 Major Amendment to a Portion of Foothills Mall Redevelopment Planning Area 3 Modified Rain Garden 33 Choose One Choose One Choose One Sheet Flow- No Energy Dissipation Required Concentrated Flow- Energy Dissipation Provided Plantings Seed (Plan for frequent weed control) Sand Grown or Other High Infiltration Sod Choose One YES NO YES NO Rain Garden 33.0 Calcs.xlsm, RG 4/24/2015, 1:57 PM Exhibit F Modified Rain Garden, RG33 1of 2 R TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard Exhibit G Sub-Basin Discharge and Inlet Sizing Foothills Mall Multi-Famliy INLET SIZING BASIN AREA (AC) COEFF. (C) Tc C*A I 2-year (in./ hr.) I 100-year (in./ hr.) Q 2-year (cfs) Q 100-year (cfs) INLET INLET SIZE (in) HEAD (ft) CAPACITY 300 0.14 0.28 5.00 0.04 2.85 9.95 0.11 0.50 3-1.0 24 0.25 2.73 301 0.47 0.75 5.00 0.35 2.85 9.95 1.01 4.40 3-2.1 24 0.35 3.63 302 0.14 0.75 5.00 0.10 2.85 9.95 0.29 1.26 3-2.0 24 0.47 4.12 303 0.16 0.70 5.00 0.11 2.85 9.95 0.32 1.40 3-14.0 24 0.12 0.91 304 0.15 0.90 5.00 0.14 2.85 9.95 0.39 1.72 3-3.1 24 0.29 3.29 305 0.47 0.75 5.00 0.35 2.85 9.95 1.00 4.36 3-4.1 34 0.35 5.35 306 0.13 0.75 5.00 0.10 2.85 9.95 0.29 1.25 3-4.0 30 0.73 8.71 307 0.18 0.71 5.00 0.13 2.85 9.95 0.36 1.56 3-8.0 24 0.36 3.68 308 0.16 0.72 5.00 0.11 2.85 9.95 0.32 1.39 3-7.0 24 0.31 3.47 309 0.05 0.78 5.00 0.04 2.85 9.95 0.10 0.45 3-9.0 24 0.12 0.91 310 0.10 0.72 5.00 0.07 2.85 9.95 0.20 0.89 3-10.0 24 0.44 4.00 311 0.47 0.76 5.00 0.36 2.85 9.95 1.02 4.45 3-10.1 24 0.35 3.63 312 0.13 0.90 5.00 0.12 2.85 9.95 0.34 1.48 3-11.1 24 0.20 2.03 313 0.27 0.73 5.00 0.19 2.85 9.95 0.56 2.42 3-12.1 24 0.10 0.63 314 0.47 0.75 5.00 0.35 2.85 9.95 1.00 4.37 3-12.2 24 0.35 3.63 400 0.14 0.85 5.00 0.12 2.85 9.95 0.35 1.51 4-3.0 30 0.42 6.80 401 0.49 0.75 5.00 0.37 2.85 9.95 1.06 4.62 4-4.1 30 0.50 7.29 402 0.53 0.73 5.00 0.39 2.85 9.95 1.10 4.80 4-5.0 30 0.31 4.58 403 0.18 0.90 5.00 0.16 2.85 9.95 0.46 1.99 4-6.1 24 0.20 2.03 404 0.49 0.76 5.00 0.37 2.85 9.95 1.07 4.65 4-8.0 24 0.50 4.25 500 0.43 0.88 5.00 0.38 2.85 9.95 1.07 4.68 5-5.0 30 0.30 4.38 501 0.31 0.95 5.00 0.30 2.85 9.95 0.84 3.67 5-7.0 24 0.25 2.73 502 0.08 0.29 5.00 0.02 2.85 9.95 0.07 0.30 5-4.0 24 0.50 4.25 503 0.19 0.88 5.00 0.17 2.85 9.95 0.48 2.10 5-3.0 24 0.52 4.33 504 0.30 0.89 5.00 0.26 2.85 9.95 0.75 3.27 5-1.0 30 0.56 7.66 505 0.25 0.80 5.00 0.20 2.85 9.95 0.56 2.46 5-1.1 24 0.58 4.57 506 0.35 0.91 5.00 0.32 2.85 9.95 0.92 4.01 5-2.2 24 0.78 5.39 600 0.27 0.95 5.00 0.26 2.85 9.95 0.73 3.19 6-1.1 30 0.50 7.29 601 0.18 0.81 5.00 0.14 2.85 9.95 0.41 1.79 6-3.0 30 0.70 8.53 602 0.20 0.93 5.00 0.19 2.85 9.95 0.54 2.36 6-5.0 30 1.00 10.38 603 0.20 0.90 5.00 0.18 2.85 9.95 0.52 2.25 6-5.1 24 0.90 5.88 604 0.30 0.92 5.00 0.28 2.85 9.95 0.79 3.46 6-7.2 24 1.16 6.95 605 0.18 0.81 5.00 0.15 2.85 9.95 0.43 1.86 6-7.1 24 0.50 4.25 606 0.16 0.93 5.00 0.15 2.85 9.95 0.42 1.85 6-7.0 30 0.60 7.91 607 0.20 0.94 5.00 0.19 2.85 9.95 0.54 2.36 6-9.0 24 0.94 6.05 608 0.20 0.81 5.00 0.16 2.85 9.95 0.47 2.05 6-9.1 24 1.12 6.78 609 0.23 0.95 5.00 0.22 2.85 9.95 0.63 2.75 6-10.1 24 0.40 3.84 3130 Verona Avenue • Buford, GA 30518 (866) 888-8479 / (770) 932-2443 • Fax: (770) 932-2490 © Nyloplast Inlet Capacity Charts June 2012 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90 0.95 1.00 1.05 1.10 Capacity (cfs) Head (ft) Nyloplast 24" Standard Grate Inlet Capacity Chart 4.59 2.62 Exhibit I Inlet Capacities 1of 2 3130 Verona Avenue • Buford, GA 30518 (866) 888-8479 / (770) 932-2443 • Fax: (770) 932-2490 © Nyloplast Inlet Capacity Charts June 2012 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90 0.95 1.00 1.05 1.10 Capacity (cfs) Head (ft) Nyloplast 30" Standard Grate Inlet Capacity Chart 3.21 7.60 Exhibit I Inlet Capacities 2 of 2 TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard R BUILDING 1 TYPE D3 BUILDING 2 TYPE C3 BUILDING 3 TYPE E2 BUILDING 4 TYPE D2 BUILDING 5 TYPE D3 BUILDING 6 TYPE C3 BUILDING 7 TYPE E2 BUILDING 8 TYPE D2 -5.0% -1.8% -2.0% -1.9% -1.9% -3.0% -4.9% -2.6% -4.3% -1.4% -2.0% -1.7% -2.6% -1.0% -1.0% -1.0% -1.1% -0.6% -0.7% -2.0% -2.0% -1.0% -2.0% -2.0% -1.0% -1.0% -2.0% -4.7% -2.1% -1.4% -4.4% -1.0% -1.0% -1.7% -1.0% -4.4% -2.0% -1.0% -1.0% -1.0% -5.3% -0.5% -1.4% -4.3% -4.1% -1.8% -2.0% TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard R Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Lot 3 Profile 1 TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard R Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Lot 3 Profile 2 TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard R Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Lot 3 Profile 3 Scenario: 100 year Base Current Time Step: 0Hr FlexTable: Conduit Table F:\Projects\015-0720\Documents\Reports\Drainage\StormCAD\Lot 3 West.stsw Label Start Node Stop Node Invert (Stop) (ft) Length (Scaled) (ft) Slope (Calculated) (ft/ft) Diameter (in) Flow (cfs) Velocity (ft/s) Depth (Out) (ft) Manning's n 12" INLET 3-2.1 INLET 3-2.0 5,004.74 50.7 0.005 12 3.51 4.66 0.80 0.010 12" INLET 3-1.0 INLET 3-2.0 5,004.74 76.5 0.017 12 0.40 4.32 0.34 0.010 18" INLET 3-2.0 SDMH 3-3.0 5,001.81 123.7 0.020 18 4.82 9.02 0.95 0.010 18" INLET 3-3.1 SDMH 3-3.0 5,001.81 38.4 0.005 18 1.40 3.89 0.95 0.010 18" SDMH 3-3.0 INLET 3-14.0 5,001.17 79.8 0.008 18 6.11 6.96 1.03 0.010 12" INLET 3-4.1 INLET 3-4.0 5,001.38 46.1 0.005 12 3.51 4.66 0.87 0.010 18" INLET 3-14.0 INLET 3-4.0 5,000.88 34.9 0.008 18 7.08 7.23 1.37 0.010 24" INLET 3-4.0 SDMH 3-5.0 5,000.17 112.3 0.002 24 11.32 4.52 1.94 0.010 24" SDMH 3-5.0 SDMH 3-6.0 5,000.03 70.7 0.002 24 11.04 4.79 2.00 0.010 24" SDMH 3-6.0 FES 3-1.0 5,000.01 11.0 0.001 24 10.89 4.09 2.00 0.010 Page 1 of 1 file:///C:/Users/bmathisen/AppData/Local/Temp/Bentley/StormCAD/uye2sprj.xml 1/27/2016 Lot 3 Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Scenario: 100 year Base Current Time Step: 0Hr FlexTable: Catch Basin Table F:\Projects\015-0720\Documents\Reports\Drainage\StormCAD\Lot 3 West.stsw ID Label Elevation (Ground) (ft) Elevation (Rim) (ft) Elevation (Invert) (ft) Hydraulic Grade Line (In) (ft) External Tc (min) External CA (acres) System Intensity (in/h) 116 INLET 3-1.0 5,008.75 5,008.75 5,006.01 5,006.27 5 0.040 9.950 117 INLET 3-2.0 5,007.96 5,007.96 5,004.24 5,005.09 5 0.100 9.761 118 INLET 3-2.1 5,009.10 5,009.10 5,002.99 5,005.88 5 0.350 9.950 120 INLET 3-3.1 5,006.57 5,006.57 5,000.00 5,002.76 5 0.140 9.950 122 INLET 3-14.0 5,005.56 5,005.56 5,001.17 5,002.20 5 0.110 9.492 123 INLET 3-4.0 5,005.29 5,005.29 5,000.38 5,002.25 5 0.100 9.441 124 INLET 3-4.1 5,005.85 5,005.85 4,999.60 5,002.49 5 0.350 9.950 Page 1 of 1 file:///C:/Users/bmathisen/AppData/Local/Temp/Bentley/StormCAD/fr0hjvsa.xml 1/27/2016 Lot 3 Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Scenario: 100 year Base Current Time Step: 0Hr FlexTable: Manhole Table F:\Projects\015-0720\Documents\Reports\Drainage\StormCAD\Lot 3 West.stsw ID Label Elevation (Ground) (ft) Elevation (Rim) (ft) Elevation (Invert in 1) (ft) Hydraulic Grade Line (Out) (ft) Hydraulic Grade Line (In) (ft) 70 SDMH 3-5.0 5,004.60 5,004.60 5,000.17 5,002.11 5,002.11 71 SDMH 3-6.0 5,003.68 5,003.68 5,000.03 5,002.02 5,002.02 128 SDMH 3-3.0 5,006.52 5,006.52 5,001.81 5,002.77 5,002.77 Page 1 of 1 file:///C:/Users/bmathisen/AppData/Local/Temp/Bentley/StormCAD/lrlgddkv.xml 1/27/2016 Lot 3 Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard R BUILDING 10 TYPE D2 BUILDING 11 TYPE C2 BUILDING 12 TYPE E1 BUILDING 13 TYPE D1 BUILDING 9 -2.0% -1.5% -4.7% -2.0% -2.0% -2.2% -2.1% -4.3% -1.7% -4.3% -6.5% -2.5% -2.1% -2.5% -2.1% -3.2% -3.2% -2.0% -2.0% -1.0% -1.0% -2.0% -1.5% -1.0% -1.0% -1.4% -2.0% -1.0% -2.5% -3.5% -1.0% -2.0% -1.0% -1.0% -1.0% -2.0% -2.2% -2.1% -1.7% -2.5% -4.1% -2.5% -4.3% -1.0% -4.3% -4.3% -4.4% -1.0% TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard R Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Lot 4 Scenario: 100 year Current Time Step: 0.000Hr FlexTable: Conduit Table F:\Projects\015-0720\Documents\Reports\Drainage\StormCAD\Lot 4.stsw Label Start Node Stop Node Invert (Stop) (ft) Length (Scaled) (ft) Slope (Calculated) (ft/ft) Diameter (in) Flow (cfs) Velocity (ft/s) Depth (Out) (ft) Manning's n 12" INLET 4-8.0 SDMH 4-7.0 5,002.67 45.9 0.005 12 3.71 4.72 0.99 0.010 12" SDMH 4-7.0 SDMH 4-6.0 5,002.01 131.7 0.005 12 3.67 4.68 0.82 0.010 12" INLET 4-6.1 SDMH 4-6.0 5,002.01 95.4 0.010 12 1.60 5.36 0.41 0.010 12" INLET 4-4.1 SDMH 4-4.0 5,000.81 39.4 0.005 12 3.71 4.72 0.82 0.010 24" SDMH 4-2.0 SDMH 4-1.0 4,999.41 71.4 0.003 24 13.08 5.69 1.67 0.010 24" SDMH 4-1.0 WALL PENETRATION 4,999.01 80.9 0.005 24 12.93 6.98 2.00 0.010 18" SDMH 4-6.0 INLET 4-5.0 5,000.55 62.4 0.015 18 5.10 8.39 0.59 0.010 24" INLET 4-3.0 SDMH 4-2.0 4,999.62 34.8 0.002 24 13.17 4.77 1.56 0.010 24" INLET 4-5.0 SDMH 4-4.0 4,999.81 47.6 0.005 24 8.78 6.34 1.56 0.010 24" SDMH 4-4.0 INLET 4-3.0 4,999.69 58.1 0.002 24 12.21 4.75 1.57 0.010 Page 1 of 1 file:///C:/Users/bmathisen/AppData/Local/Temp/Bentley/StormCAD/jbntedoq.xml 1/27/2016 Lot 4 Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Scenario: 100 year Current Time Step: 0Hr FlexTable: Catch Basin Table F:\Projects\015-0720\Documents\Reports\Drainage\StormCAD\Lot 4.stsw ID Label Elevation (Ground) (ft) Elevation (Rim) (ft) Elevation (Invert) (ft) Hydraulic Grade Line (In) (ft) External Tc (min) External CA (acres) System Intensity (in/h) 125 INLET 4-3.0 5,003.43 5,003.43 4,999.69 5,001.27 5 0.120 9.267 126 INLET 4-5.0 5,003.57 5,003.57 5,000.05 5,001.34 5 0.390 9.467 127 INLET 4-4.1 5,004.78 5,004.78 5,001.01 5,001.94 5 0.370 9.950 128 INLET 4-6.1 5,005.45 5,005.45 5,000.96 5,003.50 5 0.160 9.950 129 INLET 4-8.0 5,006.67 5,006.67 5,002.90 5,003.96 5 0.370 9.950 Page 1 of 1 file:///C:/Users/bmathisen/AppData/Local/Temp/Bentley/StormCAD/aqzmsf0h.xml 1/27/2016 Lot 4 Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Scenario: 100 year Current Time Step: 0Hr FlexTable: Manhole Table F:\Projects\015-0720\Documents\Reports\Drainage\StormCAD\Lot 4.stsw ID Label Elevation (Ground) (ft) Elevation (Rim) (ft) Elevation (Invert in 1) (ft) Hydraulic Grade Line (Out) (ft) Hydraulic Grade Line (In) (ft) 51 SDMH 4-7.0 5,005.62 5,005.62 5,002.67 5,003.66 5,003.66 66 SDMH 4-1.0 5,004.70 5,004.70 4,999.41 5,001.08 5,001.08 71 SDMH 4-6.0 5,004.28 5,004.28 5,002.01 5,002.38 5,002.38 72 SDMH 4-2.0 5,004.27 5,004.27 4,999.62 5,001.18 5,001.18 74 SDMH 4-4.0 5,004.03 5,004.03 5,000.81 5,001.37 5,001.37 Page 1 of 1 file:///C:/Users/bmathisen/AppData/Local/Temp/Bentley/StormCAD/xvy0y4ju.xml 1/27/2016 Lot 4 Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard R -1.5% -2.0% BUILDING 14 TYPE D1 BUILDING 15 TYPE C1 BUILDING 16 TYPE B BUILDING 17 TYPE A -2.0% -1.0% -2.0% -2.0% -2.0% -4.2% -4.4% -2.0% -2.0% -1.0% -2.0% -4.7% -2.0% -1.5% -2.0% -2.0% -2.1% -4.0% -1.8% -2.3% -2.1% -2.1% -3.8% -3.8% -3.6% -3.2% -2.5% -2.5% -2.0% -2.1% -2.6% -4.7% -2.5% -1.0% -1.0% -1.0% -1.0% -2.7% -1.0% -1.0% -1.5% -1.0% -1.0% -1.0% -1.0% -2.0% -1.0% -1.0% -4.4% -2.0% -1.3% TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard R Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Lot 5 Profile 1 TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard R Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Lot 5 Profile 2 TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard R Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Lot 5 Profile 3 Scenario: 100 year Current Time Step: 0.000Hr FlexTable: Conduit Table F:\Projects\015-0720\Documents\Reports\Drainage\StormCAD\Lot 5.stsw Label Start Node Stop Node Invert (Stop) (ft) Length (Scaled) (ft) Slope (Calculated) (ft/ft) Diameter (in) Flow (cfs) Velocity (ft/s) Depth (Out) (ft) Manning's n 18" TEE SDMH 5-6.0 5,008.45 19.1 0.030 18 2.97 9.14 0.66 0.010 18" SDMH 5-6.0 INLET 5-5.0 5,006.80 54.9 0.030 18 2.96 9.14 1.00 0.010 12" INLET 5-7.0 TEE 5,009.52 73.5 0.007 12 3.01 5.60 0.65 0.010 18" INLET 5-5.0 FES 5-2 5,005.51 26.4 0.049 18 6.66 13.71 1.50 0.010 18" INLET 5-1.1 TEE 5,006.22 21.2 0.005 18 5.15 5.55 1.37 0.010 18" TEE INLET 5-1.0 5,006.05 55.9 0.003 18 5.13 4.55 1.48 0.010 12" INLET 5-4.0 SDMH 5-3.0 5,007.06 86.7 0.010 12 0.20 2.95 0.47 0.010 12" SDMH 5-3.0 INLET 5-2.0 5,006.91 30.6 0.005 12 0.19 2.29 0.62 0.010 18" INLET 5-2.0 INLET 5-1.0 5,006.05 71.3 0.005 18 1.82 4.19 1.48 0.010 24" INLET 5-1.0 FES 5-1 5,005.51 20.2 0.002 24 9.11 4.52 2.00 0.010 12" INLET 5-2.2 INLET 5-1.1 5,006.82 54.6 0.005 12 3.21 4.75 0.77 0.010 Page 1 of 1 file:///C:/Users/bmathisen/AppData/Local/Temp/Bentley/StormCAD/u0hroies.xml 1/27/2016 Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Lot 5 Scenario: 100 year Current Time Step: 0Hr FlexTable: Catch Basin Table F:\Projects\015-0720\Documents\Reports\Drainage\StormCAD\Lot 5.stsw ID Label Elevation (Ground) (ft) Elevation (Rim) (ft) Elevation (Invert) (ft) Hydraulic Grade Line (In) (ft) External Tc (min) External CA (acres) System Intensity (in/h) 120 INLET 5-2.2 5,009.50 5,009.50 5,007.10 5,007.90 5 0.320 9.950 121 INLET 5-1.1 5,009.96 5,009.96 5,006.32 5,007.60 5 0.200 9.827 122 INLET 5-1.0 5,010.07 5,010.07 5,005.55 5,007.53 5 0.260 9.312 123 INLET 5-2.0 5,010.10 5,010.10 5,006.41 5,007.53 5 0.170 9.494 124 INLET 5-4.0 5,010.42 5,010.42 5,007.93 5,008.11 5 0.020 9.950 134 INLET 5-7.0 5,012.91 5,012.91 5,010.07 5,010.82 5 0.300 9.950 138 INLET 5-5.0 5,010.68 5,010.68 5,006.60 5,007.80 5 0.380 9.724 Page 1 of 1 file:///C:/Users/bmathisen/AppData/Local/Temp/Bentley/StormCAD/lpl1fyfj.xml 1/27/2016 Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Lot 5 Scenario: 100 year Current Time Step: 0Hr FlexTable: Manhole Table F:\Projects\015-0720\Documents\Reports\Drainage\StormCAD\Lot 5.stsw ID Label Elevation (Ground) (ft) Elevation (Rim) (ft) Elevation (Invert in 1) (ft) Hydraulic Grade Line (Out) (ft) Hydraulic Grade Line (In) (ft) 42 TEE 5,013.80 5,013.80 5,009.52 5,009.68 5,009.68 63 TEE 5,010.55 5,010.55 5,006.22 5,007.59 5,007.59 64 SDMH 5-3.0 5,010.49 5,010.49 5,007.06 5,007.53 5,007.53 137 SDMH 5-6.0 5,014.07 5,014.07 5,008.45 5,009.10 5,009.10 Page 1 of 1 file:///C:/Users/bmathisen/AppData/Local/Temp/Bentley/StormCAD/5nkemck3.xml 1/27/2016 Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Lot 5 TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard R BUILDING 18 -3.9% BUILDING 19 -3.6% -3.7% -2.0% -2.0% -2.0% -4.4% -4.5% -2.0% -1.0% -1.0% -2.2% -1.0% -2.3% -1.4% -2.0% -3.3% -2.0% -1.7% -2.0% -2.0% -2.0% -2.0% -2.0% -2.5% -2.0% -2.0% -1.7% -2.0% -1.0% -0.7% -1.0% -1.0% -2.0% -1.3% -2.0% -0.1% -2.0% -1.5% -1.0% -1.0% -2.0% -1.0% -2.0% -1.0% -2.0% -1.2% -2.0% -4.4% -4.4% -2.0% -2.0% -2.0% -1.0% -1.0% -4.4% -1.9% -2.0% TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard R Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Lot 6 Scenario: 100 year Current Time Step: 0.000Hr FlexTable: Conduit Table F:\Projects\015-0720\Documents\Reports\Drainage\StormCAD\Lot 6.stsw Label Start Node Stop Node Invert (Stop) (ft) Length (Scaled) (ft) Slope (Calculated) (ft/ft) Diameter (in) Flow (cfs) Velocity (ft/s) Depth (Out) (ft) Manning's n 10" INLET 6-10.3 TEE 5,012.01 35.9 0.004 10 2.81 5.15 0.73 0.010 12" TEE TEE 5,011.79 10.3 0.005 12 2.79 4.68 0.71 0.010 18" TEE TEE 5,010.87 5.1 0.008 18 5.50 6.60 1.07 0.010 18" TEE INLET 6-10.1 5,010.78 41.1 0.002 18 5.49 4.07 1.07 0.010 16" INLET 6-10.2 TEE 5,011.08 30.1 0.008 16 5.52 6.63 0.80 0.010 12" TEE INLET 6-10.2 5,011.64 30.2 0.005 12 2.78 4.68 0.71 0.010 30" INLET 6-5.0 SDMH 6-4.0 5,008.51 75.2 0.002 30 19.26 5.28 2.25 0.010 30" SDMH 6-4.0 INLET 6-3.0 5,008.36 67.4 0.002 30 19.00 5.52 2.33 0.010 18" INLET 6-10.1 TEE 5,010.61 15.2 0.011 18 7.56 8.33 0.89 0.010 24" TEE SDMH 6-10.0 5,009.95 46.5 0.003 24 7.55 5.31 0.93 0.010 24" SDMH 6-10.0 INLET 6-9.0 5,009.64 61.1 0.005 24 7.47 6.07 1.17 0.010 30" INLET 6-7.0 SDMH 6-6.0 5,008.70 26.0 0.003 30 16.00 5.80 2.15 0.010 30" SDMH 6-6.0 INLET 6-5.0 5,008.65 34.1 0.002 30 15.94 4.65 2.18 0.010 24" INLET 6-9.0 SDMH 6-8.0 5,009.41 42.3 0.005 24 10.71 6.89 1.45 0.010 24" SDMH 6-8.0 INLET 6-7.0 5,009.27 32.8 0.004 24 10.63 6.30 1.60 0.010 12" INLET 6-1.1 SDMH 6-1.0 5,009.21 49.6 0.010 12 2.61 6.07 1.32 0.010 18" INLET 6-7.2 INLET 6-7.1 5,009.87 122.5 0.005 18 2.81 4.73 0.99 0.010 30" SDMH 6-1.0 WALL PENETRATION 5,008.01 11.0 0.005 30 21.86 7.96 2.50 0.010 30" SDMH 6-2.0 SDMH 6-1.0 5,008.07 119.8 0.002 30 19.96 5.44 2.46 0.010 12" INLET 6-5.1 INLET 6-5.0 5,010.15 19.7 0.005 12 1.81 4.27 0.68 0.010 18" INLET 6-7.1 INLET 6-7.0 5,009.77 19.7 0.005 18 4.19 5.27 1.10 0.010 12" INLET 6-9.1 INLET 6-9.0 5,010.64 41.6 0.005 12 1.60 4.15 0.49 0.010 30" INLET 6-3.0 SDMH 6-2.0 5,008.30 26.4 0.002 30 20.05 5.56 2.36 0.010 Page 1 of 1 file:///C:/Users/bmathisen/AppData/Local/Temp/Bentley/StormCAD/4sirtckr.xml 1/27/2016 Lot 6 Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Scenario: 100 year Current Time Step: 0Hr FlexTable: Catch Basin Table F:\Projects\015-0720\Documents\Reports\Drainage\StormCAD\Lot 6.stsw ID Label Elevation (Ground) (ft) Elevation (Rim) (ft) Elevation (Invert) (ft) Hydraulic Grade Line (In) (ft) External Tc (min) External CA (acres) System Intensity (in/h) 117 INLET 6-10.3 5,014.46 5,014.46 5,012.17 5,013.15 5 0.280 9.950 118 INLET 6-10.2 5,014.46 5,014.46 5,011.31 5,012.25 5 0.280 9.784 119 INLET 6-10.1 5,014.46 5,014.46 5,010.78 5,011.85 5 0.220 9.619 120 INLET 6-9.1 5,013.53 5,013.53 5,008.85 5,011.39 5 0.160 9.950 121 INLET 6-9.0 5,013.86 5,013.86 5,009.64 5,010.82 5 0.190 9.399 122 INLET 6-7.0 5,013.83 5,013.83 5,008.77 5,010.87 5 0.150 9.284 123 INLET 6-7.1 5,013.95 5,013.95 5,007.87 5,010.86 5 0.150 9.674 124 INLET 6-7.2 5,014.34 5,014.34 5,008.48 5,011.12 5 0.280 9.950 125 INLET 6-5.0 5,013.83 5,013.83 5,008.65 5,010.83 5 0.190 9.184 126 INLET 6-5.1 5,013.95 5,013.95 5,008.25 5,010.82 5 0.180 9.950 127 INLET 6-3.0 5,013.34 5,013.34 5,008.36 5,010.69 5 0.140 8.959 128 INLET 6-1.1 5,014.36 5,014.36 5,007.70 5,010.68 5 0.260 9.950 Page 1 of 1 file:///C:/Users/bmathisen/AppData/Local/Temp/Bentley/StormCAD/kzaxmvvq.xml 1/27/2016 Lot 6 Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Scenario: 100 year Current Time Step: 0Hr FlexTable: Manhole Table F:\Projects\015-0720\Documents\Reports\Drainage\StormCAD\Lot 6.stsw ID Label Elevation (Ground) (ft) Elevation (Rim) (ft) Elevation (Invert in 1) (ft) Hydraulic Grade Line (Out) (ft) Hydraulic Grade Line (In) (ft) 50 TEE 5,014.83 5,014.83 5,012.01 5,012.56 5,012.56 51 TEE 5,014.82 5,014.82 5,010.87 5,011.94 5,011.94 52 TEE 5,014.77 5,014.77 5,011.08 5,011.91 5,011.91 53 TEE 5,014.77 5,014.77 5,011.79 5,012.51 5,012.51 55 SDMH 6-4.0 5,014.67 5,014.67 5,008.51 5,010.76 5,010.76 56 TEE 5,014.62 5,014.62 5,010.61 5,011.09 5,011.09 57 SDMH 6-10.0 5,014.52 5,014.52 5,009.95 5,010.92 5,010.92 58 SDMH 6-6.0 5,014.48 5,014.48 5,008.70 5,010.85 5,010.85 62 SDMH 6-8.0 5,014.45 5,014.45 5,009.41 5,010.87 5,010.87 65 SDMH 6-1.0 5,014.31 5,014.31 5,009.21 5,010.53 5,010.53 71 SDMH 6-2.0 5,013.62 5,013.62 5,008.30 5,010.66 5,010.66 Page 1 of 1 file:///C:/Users/bmathisen/AppData/Local/Temp/Bentley/StormCAD/rd5sfcjz.xml 1/27/2016 Lot 6 Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations REVISIONS NO. REV. DATE REVISIONS DESCRIPTION project no.: approved by: checked by: drawn by: drawing no.: QA/QC by: date: SHEET TEL 970.461.7733 www.olssonassociates.com 5285 McWhinney Boulevard, Suite 160 Loveland, CO 80538 OLSSON ASSOCIATES ASSUMES NO RESPONSIBILITY FOR EXISTING UTILITY LOCATIONS (HORIZONTAL OR VERTICAL). THE EXISTING UTILITIES SHOWN ON THIS DRAWING HAVE BEEN PLOTTED FROM THE BEST AVAILABLE INFORMATION. IT IS HOWEVER THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITIES. NOTE THIS DOCUMENT HAS BEEN RELEASED BY OLSSON ASSOCIATES ONLY FOR REVIEW BY REGULATORY AGENCIES AND OTHER PROFESSIONALS, AND IS SUBJECT TO CHANGE. THIS DOCUMENT IS NOT TO BE USED FOR CONSTRUCTION. CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES R CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: DATE DATE DATE DATE DATE DATE CITY ENGINEER WATER AND WASTEWATER UTILITY STORMWATER UTILITY PARKS AND RECREATION TRAFFIC ENGINEER SUB-BASIN MAP FORT COLLINS, CO 2016 01/27/2016 015-0720 FOOTHILLS MALL MULTI-FAMILY DH 150720_DRN02.dwg JG MH EXHIBIT J A 12/21/2015 01/27/2016 1ST FDP SUBMITTAL 2ND FDP SUBMITTAL B CONSTRUCTION DOCUMENTS DRAINAGE NOTES JD 1. Reference Addendum 3 Drainage Analysis for the Major Amendment to a Portion of Foothills Mall Redevelopment Planning Area 3 (Lots 3, 4, 5, and 6 of Foothills Mall Redevelopment) -1.5% -2.0% BUILDING 14 TYPE D1 BUILDING 15 TYPE C1 BUILDING 16 TYPE B BUILDING 17 TYPE A -2.0% -1.0% -2.0% -2.0% -2.0% -4.2% -4.4% -2.0% -2.0% -1.0% -2.0% -4.7% -2.0% -1.5% -2.0% -2.0% -2.1% -4.0% -1.8% -2.3% -2.1% -2.1% -3.8% -3.8% -3.6% -3.2% -2.5% -2.5% -2.0% -2.1% -2.6% -4.7% -2.5% -1.0% -1.0% -1.0% -1.0% -2.7% -1.0% -1.0% -1.5% -1.0% -1.0% -1.0% -1.0% -2.0% -1.0% -1.0% -4.4% -2.0% -1.3% -1.0% -3.9% -2.0% -1.5% -0.8% 1.0% -1.4% -2.0% -0.4% -3.5% -1.0% -3.0% -3.1% -2.5% -3.0% -2.0% -1.0% -1.0% -2.3% -2.0% -0.8% -2.0% -2.6% -2.9% -1.0% -3.2% -1.0% -4.1% -1.6% -1.0% -1.6% -4.1% -1.0% -1.0% -1.0% -1.5% -1.8% -1.9% -1.0% -3.1% -2.2% BUILDING 10 TYPE D2 BUILDING 11 TYPE C2 BUILDING 12 TYPE E1 BUILDING 13 TYPE D1 BUILDING 9 -2.0% -1.5% -4.7% -2.0% -2.0% -2.2% -2.1% -4.3% -1.7% -4.3% -6.5% -2.5% -2.1% -2.5% -2.1% -3.2% -3.2% -2.0% -2.0% -1.0% -1.0% -2.0% -1.5% -1.0% -1.0% -1.4% -2.0% -1.0% -2.5% -3.5% -1.0% -2.0% -1.0% -1.0% -1.0% -2.0% -2.2% -2.1% -1.7% -2.5% -4.1% -2.5% -4.3% -1.0% -4.3% -4.3% -4.4% -1.0% -1.6% -1.0% -2.6% -2.6% -1.0% -2.0% -3.2% -1.0% -2.0% -2.6% -3.3% -1.7% -4.3% -6.6% -2.2% -2.1% -2.5% -2.1% -3.2% -1.7% -2.5% -1.8% -2.5% -4.4% -2.5% -2.6% -2.6% -1.1% -1.6% -2.0% 402 404 403 401 400 500 501 503 502 506 505 504 BUILDING 18 -3.9% BUILDING 19 -3.6% -3.7% -2.0% -2.0% -2.0% -4.4% -4.5% -2.0% -1.0% -1.0% -2.2% -1.0% -2.3% -1.4% -2.0% -3.3% -2.0% -1.7% -2.0% -2.0% -2.0% -2.0% -2.0% -2.5% -2.0% -2.0% -1.7% -2.0% -1.0% -0.7% -1.0% -1.0% -2.0% -1.3% -2.0% -0.1% -2.0% -1.5% -1.0% -1.0% -2.0% -1.0% -2.0% -1.0% -2.0% -1.2% -2.0% -4.4% -4.4% -2.0% -2.0% -2.0% -1.0% -1.0% -4.4% -1.9% -2.0% -2.0% -1.0% -1.0% -0.9% -1.2% -1.0% -1.9% -2.0% -1.4% -2.0% -2.0% -2.0% -2.0% -2.0% -1.2% -2.0% -4.7% -2.2% -1.6% -2.0% -2.0% -2.0% -4.1% -1.6% -4.3% -2.0% -4.5% -1.0% -1.0% -2.0% -2.0% -1.8% BUILDING 1 TYPE D3 BUILDING 2 TYPE C3 BUILDING 3 TYPE E2 BUILDING 4 TYPE D2 BUILDING 5 TYPE D3 BUILDING 6 TYPE C3 BUILDING 7 TYPE E2 BUILDING 8 TYPE D2 -5.0% -1.8% -2.0% -1.9% -1.9% -3.0% -4.9% -2.6% -4.3% -1.4% -2.0% -1.7% -2.6% -1.0% -1.0% -1.0% -1.1% -0.6% -0.7% -2.0% -2.0% -1.0% -2.0% -2.0% -1.0% -1.0% -2.0% -4.7% -2.1% -1.4% -4.4% -1.0% -1.0% -1.7% -1.0% -4.4% -2.0% -1.0% -1.0% -1.0% -5.3% -0.5% -1.4% -4.3% -4.1% -1.8% -2.0% -2.4% -2.0% -2.0% -2.0% -2.0% -2.0% -2.0% -2.0% -2.0% -1.0% -1.0% -2.0% -1.0% -1.0% -1.0% -1.0% -1.0% -2.1% -2.0% -2.0% -2.0% -2.0% -3.3% -2.0% -2.0% -3.5% -3.3% -1.0% -1.0% -1.0% -1.7% -1.0% -2.8% -1.0% -1.0% -0.9% -2.0% -3.1% -1.0% -1.0% -1.0% -1.0% -1.0% -4.7% -2.3% -2.9% -2.1% -5.0% -1.8% -2.1% -1.9% -1.6% -3.0% -4.9% -4.8% -2.6% -1.4% -2.1% -1.6% -3.4% -2.0% -2.0% -3.0% -2.1% -2.5% -1.3% -1.2% -3.0% -1.0% -1.0% -1.0% -1.0% -1.0% -1.3% -1.3% -2.0% -2.0% -1.5% -2.7% -1.5% -1.0% -0.9% -2.4% -4.5% -1.8% -2.0% -1.9% -1.7% -3.0% -4.3% -2.6% -3.8% -1.0% -2.0% -1.6% -2.4% -1.5% -2.0% -2.9% -2.1% -2.4% -2.6% -1.0% -1.1% -1.0% -1.1% -0.6% -0.7% -1.0% -1.0% -1.5% -1.5% -2.1% -2.2% -2.7% -1.5% -1.5% -1.0% -0.9% -2.7% -5.0% -1.8% -2.0% -2.0% -2.0% -3.0% -4.8% -7.2% -2.6% -1.0% -2.0% -1.6% -3.4% -2.0% -2.0% -3.0% -2.1% -2.6% -0.9% -2.0% -2.0% -2.0% -2.0% -2.0% -2.0% -2.0% -2.0% -2.0% -2.0% -4.3% -4.6% -4.1% -3.2% -3.1% 604 601 602 606 610 611 600 609 607 605 608 603 314 310 313 308 306 305 302 300 312 -2.0% -1.0% -1.0% -0.9% -1.2% -1.0% -1.9% -2.0% -1.4% -2.0% -2.0% -2.0% -2.0% -2.0% -1.2% -2.0% -4.7% -2.2% -1.6% -2.0% -2.0% -2.0% -4.1% -1.6% -4.3% -2.0% -4.5% -1.0% -1.0% -2.0% -2.0% -1.8% Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Lot 6 Model Profile Alignment -1.0% -3.9% -2.0% -1.5% -0.8% 1.0% -1.4% -2.0% -0.4% -3.5% -1.0% -3.0% -3.1% -2.5% -3.0% -2.0% -1.0% -1.0% -2.3% -2.0% -0.8% -2.0% -2.6% -2.9% -1.0% -3.2% -1.0% -4.1% -1.6% -1.0% -1.6% -4.1% -1.0% -1.0% -1.0% -1.5% -1.8% -1.9% -1.0% -3.1% -2.2% Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Lot 5 Model Profile Alignment Profile 3 Profile 2 Profile 1 -1.6% -1.0% -2.6% -2.6% -1.0% -2.0% -3.2% -1.0% -2.0% -2.6% -3.3% -1.7% -4.3% -6.6% -2.2% -2.1% -2.5% -2.1% -3.2% -1.7% -2.5% -1.8% -2.5% -4.4% -2.5% -2.6% -2.6% -1.1% -1.6% -2.0% Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Lot 4 Model Profile Alignment -2.4% -2.0% -2.0% -2.0% -2.0% -2.0% -2.0% -2.0% -2.0% -1.0% -1.0% -2.0% -1.0% -1.0% -1.0% -1.0% -1.0% -2.1% -2.0% -2.0% -2.0% -2.0% -3.3% -2.0% -2.0% -3.5% -3.3% -1.0% -1.0% -1.0% -1.7% -1.0% -2.8% -1.0% -1.0% -0.9% -2.0% -3.1% -1.0% -1.0% -1.0% -1.0% -1.0% -4.7% -2.3% -2.9% -2.1% -5.0% -1.8% -2.1% -1.9% -1.6% -3.0% -4.9% -4.8% -2.6% -1.4% -2.1% -1.6% -3.4% -2.0% -2.0% -3.0% -2.1% -2.5% -1.3% -1.2% -3.0% -1.0% -1.0% -1.0% -1.0% -1.0% -1.3% -1.3% -2.0% -2.0% -1.5% -2.7% -1.5% -1.0% -0.9% -2.4% -4.5% -1.8% -2.0% -1.9% -1.7% -3.0% -4.3% -2.6% -3.8% -1.0% -2.0% -1.6% -2.4% -1.5% -2.0% -2.9% -2.1% -2.4% -2.6% -1.0% -1.1% -1.0% -1.1% -0.6% -0.7% -1.0% -1.0% -1.5% -1.5% -2.1% -2.2% -2.7% -1.5% -1.5% -1.0% -0.9% -2.7% -5.0% -1.8% -2.0% -2.0% -2.0% -3.0% -4.8% -7.2% -2.6% -1.0% -2.0% -1.6% -3.4% -2.0% -2.0% -3.0% -2.1% -2.6% -0.9% -2.0% -2.0% -2.0% -2.0% -2.0% -2.0% -2.0% -2.0% -2.0% -2.0% -4.3% -4.6% -4.1% -3.2% -3.1% Exhibit I Foothills Mall Multi-Famliy Pipe Hydraulic Calculations Lot 3 Model Profile Alignment Profile 2 Profile 1 Profile 3 610 0.29 0.95 5.00 0.28 2.85 9.95 0.79 3.46 6-10.2 24 0.39 3.80 611 0.30 0.95 5.00 0.28 2.85 9.95 0.80 3.49 6-10.3 24 0.39 3.80 BASIN CALCULATIONS