Loading...
HomeMy WebLinkAboutSOUTHEAST FORT COLLINS COMMUNITY PARK - FDP - FDP160009 - SUBMITTAL DOCUMENTS - ROUND 1 - PHOTOMETRIC PLAN (5)14197 15385 15421 15462 15463 15464 15465 15466 15467 15468 15469 15470 15477 15476 Muskrat Ditch Muskrat Ditch Muskrat Ditch Muskrat Ditch Muskrat Ditch Muskrat Ditch 8 10 16 21 17 1 22 18 3 2 14 15 23 20 13 9 TR E TR E TR E TR E 11 R 126 110 86 ZIEGLER RD SABER CAT DR LADY MOON DR ZIEGLER RD KECHTER RD KECHTER RD ZIEGLER RD LITTLE DIPPER DR ZIEGLER RD ZIEGLER RD ZIEGLER RD X ref .\ACAD-1503 - PROTOTYPE RESTROOM - ROOF PLAN.dwg Xref .\arch\150701 - FARMHOUSE - FLOOR PLAN.dwg Xref .\ACAD-1503 - PROTOTYPE RESTROOM - ROOF PLAN.dwg Stamp: Checked: Drawn: CVT Proj. #: S S S WP GFI T M NEW 11"x18"x12" DEEP, BOTTOMLESS, HEAVY DUTY, FLUSH IN-GRADE POLYMER CONCRETE SPLICE BOX WITH TIER 22 TRAFFIC RATED BOLTED COVER. 3" SCHEDULE 80 PVC SLEEVE (4#8 THWN & 1#8 GND) TERMINATING IN SPLICE BOXES AT EACH END. (UNLESS NOTED OTHERWISE). NEW PAD MOUNTED TRANSFORMER. EXISTING LIGHTING CONTROL CENTER. CIRCUIT HOMERUN. NUMBER OF ARROWS INDICATE NUMBER OF CIRCUITS. HOLIDAY GFCI 4-PLEX RECEPTACLE IN WEATHERPROOF BACKBOX AND WEATHERPROOF WHILE IN USE METAL LOCKABLE COVER. EXISTING ELECTRICAL PANEL. NEW UTILITY METER. NEW FUSIBLE DISCONNECT. ELECTRICAL LEGEND GENERAL NOTES TO BE DEVELOPED Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC 14197 15462 15465 D D LS01 20 LS02 22 Scale: 1" = 40' 0 10 20 30 40 80 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: T SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC 15421 15463 15466 Muskrat Ditch D D D H H LS03 20 LS04 22 LS05 20 S C2 WP GFI 3 BF1-14,16,18 (3#6 THWN CU & 1#6 GND) 1" PVC S S LP1-20,22 (4#8 THWN CU & 1#8 GND) 2" PVC (4#8 THWN CU & 1#8 GND) 2" PVC (4#10 THWN CU & 1#10 GND) 2" PVC D LS17 22 Scale: 1" = 40' 0 10 20 30 40 80 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 T SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC 15466 15467 SABER CAT DR D D D D D D LS07 22 LS08 20 C2 C1 WP GFI 3 B1 A1 A2 B2 T WP GFI BF1-14,16,18 (3#6 THWN CU & 1#6 GND) 1" PVC BF1-8,10,12 (3#8 THWN CU & 1#8 GND) 1" PVC BFL1-1,3 (3#10 THWN CU & 1#10 GND) 1" PVC EMPTY 2" PVC W/ NYLON PULL STRAP WITH FOOTAGE TAPE TO ANNOUNCER'S BOOTH FOR CONTROL WIRING BF1-13,15,17 (3#6 THWN CU & 1#6 GND) 1" PVC BF1-7,9,11 (3#8 THWN CU & 1#8 GND) 1" PVC BF1-1,3,5 (3#10 THWN CU & 1#10 GND) 1" PVC BFL1-5 (2#12 THWN CU & 1#12 GND) 3/4" PVC BF1-2,4,6 (3#10 THWN CU & T T F ADD PVC UNDERDRAIN T F SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC 15467 D D D D D D LS07 22 LS08 20 B1 A1 T WP GFI BF1-7,9,11 (3#8 THWN CU & 1#8 GND) 1" PVC BF1-1,3,5 (3#10 THWN CU & 1#10 GND) 1" PVC BFL1-5 (2#12 THWN CU & 1#12 GND) 3/4" PVC BF1-2,4,6 (3#10 THWN CU & 1#10 GND) 1" PVC LS09 22 LS10 20 LS11 20 LS12 22 WP BFL1-2,4 (3#8 THWN CU & 1#8 GND) 1" PVC EMPTY 2" PVC W/ NYLON PULL STRAP WITH FOOTAGE TAPE TO ANNOUNCER'S BOOTH FOR CONTROL WIRING GFI 2 SCORE BOARD F F T T SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC 15469 LADY MOON DR WP (3#8 THWN CU & 1#8 GND) 1" PVC EMPTY 2" PVC W/ NYLON PULL STRAP WITH FOOTAGE TAPE TO ANNOUNCER'S BOOTH FOR CONTROL GFI 2 SCORE BOARD BF2-13,15,17 (3#6 THWN CU & 1#6 GND) 1" PVC C3 LS13 22 T M T BMX TRACK ANNOUNCER'S BOOTH REFER TO LANDSCAPE PLANS FOR BOOTH LOCATION WP WP WP PANEL 'LP2' 208Y/120V-3Ø-4W WP PANEL 'LP3' 208Y/120V-3Ø-4W WP WP WP BMX TRACK START GATE. COORDINATE WITH TRACK MANAGER FOR EXACT LOCATION AND POWER REQUIREMENTS. PROVIDE A 1" EMPTY PVC CONDUIT W/ NYLON PULL STRAP WITH FOOTAGE TAPE TO THE ANNOUNCER'S BOOTH FOR CONTROL TO THE START GATE. LP3-2,4 (3#10 THWN CU & T T T 360 SF WETLAND T SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC 14197 15462 15465 Muskrat Ditch D D MT MT M M M1 M1 MT MT M M D D SIGN LS04 22 LS14 20 LS15 22 LS16 20 LS17 22 T T MT MT M M M1 M1 MT MT M M Scale: 1" = 40' 0 10 20 30 40 80 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. T D C C D C SIGN LS18 20 LS19 24 LS20 26 LS21 24 (2#6 THWN CU & 1#6 GND) 1 1/4" PVC WP J 12" x 12" x 4"DP SURFACE WP BOX. Scale: 1" = 40' 0 10 20 30 40 80 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc T T F T D C C C C D D D D LS05 20 S PANEL 'LP1' 208Y/120V-3Ø-4W LS16 20 LS17 22 LS22 26 LS23 24 LS24 26 LS25 24 (4#6 THWN CU & 1#6 GND) 1 1/4" PVC (TYPICAL) S S LS26 26 LS27 26 (2#6 THWN CU & 1#6 GND) 1" PVC LP1-24,26 (4#6 THWN CU & 1#6 GND) 1 1/4" PVC S S LP1-20,22 (4#8 THWN CU & 1#8 GND) 2" PVC (4#10 THWN CU & 1#10 GND) 2" PVC M WP T CT WP UTILITY PAD MOUNTED TRANSFORMER BY FCL&P D LS17 22 S LP1-28 T SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC 15467 Muskrat Ditch Xref .\ACAD-1503 - PROTOTYPE RESTROOM - ROOF PLAN.dwg Xref .\ACAD-1503 - PROTOTYPE RESTROOM - ROOF PLAN.dwg D D D LS06 22 LS07 22 LS08 20 C1 BF1-13,15,17 (3#6 THWN CU & 1#6 GND) 1" PVC LS27 (4#8 THWN CU & 1#8 GND) 2" PVC LS17 Scale: 1" = 40' 0 10 20 30 40 80 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. F F 1.5% 2% 2% 2% 2% 2% T T T F SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC SS 15PVC 15464 15468 15469 Muskrat Ditch Muskrat Ditch LADY MOON DR D D BOOTH FOR CONTROL WP WIRING 2 C4 LS13 22 LS28 20 (2#8 THWN CU & 1#8 GND) 2" PVC D LS28 22 Scale: 1" = 40' 0 10 20 30 40 80 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 NOTE: T1B WIRED AS SLAVE TO T1A MASTER. A A1 A1 A1 F F T A1 A1 A1 A F F F F 'LP1' OR 'LP2' LP2-5 LP1-5 M T S TO OS EWH EUH 15KW T S T S M M EUH-1 15KW M M T T EWH-1 EWH-1 GFI GFI GFI OS OS TO TO TO LP1-21 OR LP2-21 LP1-23 OR LP2-23 HD-4 HD-3 HD-2 HD-1 LP1-3 OR LP2-3 LP1-15 OR LP2-15 GFI GFI LP1-9 OR LP2-9 L-2 L-2 LP1-14,16,18 OR 24" AFG G 24" AFG 24" AFG 24" AFG P P P P P P P P P P P P G G RECESSED WET LOCATION J-BOX. TYPE "G" LUMINAIRE PT RT G G G P1 R 3 LE11 4 LE12 LOCATE TRANSFORMER IN A VENTILATED ACCESSIBLE LOCATION LOW VOLTAGE WIRING LOW VOLTAGE WIRING TO 120 VOLT POWER RUN WIRING INSIDE STRUCTURAL MEMBER TO 120 VOLT POWER RUN WIRING INSIDE STRUCTURAL MEMBER NOTE: TYPE 'P' & "P1" TILTS IN ONE DIRECTION ONLY. ORIENT TYPE "P" RECESSED J-BOX SO THAT THE BEAM IS TILTED STRAIGHT DOWN. ORIENT TYPE "P1" TO AIM AT THE CENTER OF THE DECORATIVE DOOR. CEILING PLATE SHED ROOF PERLINS TYPE "P" LUMINAIRE TYPE "P1" LUMINAIRE CONDUIT WITH LOW VOLTAGE WIRING TO TRANSFORMER. WEATHERPROOF JUNCTION BOX. LOCATON TO BE DETERMINED. CONDUIT WITH LOW VOLTAGE WIRING TO LUMINAIRE. TYPE 'R' LINIER LED (4) TYPE 'LT' TRANSFORMERS S MOUNT TYPE 'L' AT NOMINAL 40', DIRECTED LIP 3 LE12 K K G K K K K G S JT KT K TO TYPE "K" RUN WIRING IN STRUCTURAL MEMBER. LOW VOLTAGE TO TYPE "J" IN SILO 1 MOUNT TYPE "JT" & "KT" 120V POWER TRANSFORMERS BELOW PORCH J 3 LE12 J J J J J (4) TYPES "LC" & "LK" IN WEATHERPROOF ENCLOSURE AT 5'. SEE 1-LINE DIAGRAM SHEET LE## JT 120V SILO 1 SILO 2 G S VERTICAL SLATS RECESSED 4" EXT. J-BOX HORIZONTAL GIRT S RUN 120V POWER TO TYPE "G" IN STRUCTURAL MEMBER TYPE "L" LUMINAIRE MOUNTED AT TOP AND BOTTOM OF LIGHT BOX MOUNTING CLIP SEE SILO DRAWING FOR CORRUGATED METAL SIDING STRUCTURAL WALL RECESSED BACK BOX IN CORRUGATED METAL SIDING TYPE 'T' LUMINAIRE RECESSED JUNCTION BOX IN STRUCTURAL WALL TYPE 'T' LUMINAIRE MOUNTED TO BACK BOX. CUT SLOT IN CORRUGATED METAL TO MOUNT BACK BOX TO STRUCTURAL WALL NOTE: TYPE 'T' LUMINAIRE MOUNTED OVER BOTH MEN AND WOMEN RESTROOM DOORS (TYPICAL). TYPE 'LT1' TRANSFORMER ENCLOSURE IN WET LOCATION CONDUIT AND WIRING TO 120V POWER SECONDARY LOW VOLTAGE WIRING (2) 10'-0" TYPE 'L1' LUMINAIRE FINISH GRADE CONCRETE FOOTINGS COMPACTED SUBGRADE TRANSFORMER TYPE 'MT' OR 'MT1' LINEAR LED LUMINAIRE TYPE 'M' OR 'M1' INGRADE WET LOCATION PULL BOX PVC CONDUIT IN 24" DEEP TRENCH. TO 120V POWER SOURCE. ELECTRICAL CONDUIT AND 120V WIRING TO DRIVER. CLASS II WIRING FROM TRANSFORMER TO LED 15" CHANNEL GREEN SCREEN FREESTANDING TRELLIS Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: 2 3 3/4" x 10'-0"Lg. COPPER CLAD DRIVEN GROUND RODS A MINIMUM OF 8'-0" APART. EXOTHERMIC WELD OR UNDERGROUND APPROVED LUG CONNECT CONDUCTOR TO RODS. UFER GROUND MINIMUM OF 20'-0" ENCASED IN NEW RESTROOM CONCRETE IN DIRECT CONTACT WITH EARTH. I sca=33,400 4 3 T 480Y/277V-3Ø-4W SEC. UTILITY PAD MOUNTED TRANSFORMER ESTIMATED TO BE (500 KVA). COORDINATE WITH FORT COLLINS LIGHT AND POWER (FCL&P) FOR EXACT SOURCE LOCATION AND TYPE. COIL 5'-0" OF CONDUCTORS AT SOURCE FOR FINAL CONNECTION BY FCL&P FORCES. 1 1 2 FEEDER SCHEDULE WP (4 #500 KCMIL CU XHHW) 3 1/2" PVC (1 #6 S.D.B.C.) 1/2"C (4 #3/0 THWN CU & 1#6 GND) 2 1/2" PVC 5 6 7 (4 #1/0 KCMIL THWN CU & 1#6 GND) 2" PVC (3 #10 THWN CU & 1#10 GND) 1" PVC (10 #10 THWN CU) 1" PVC 7 1 WP M WP 400A MLO 4 200A -3P T 2 6 5 150A -3P WEST BALL FIELD LTG. CONTROL PANEL-1 'BF1' 480Y/277V-3Ø-4W NORTH BALL FIELDS HIGH PANEL 'HP1' 480Y/277V-3Ø-4W, SERVICE ENTRANCE RATED (2) 3-POLE EQUIPPED SPACES EAST BALL FIELD LTG. CONTROL PANEL-2 'BF2' 480Y/277V-3Ø-4W PANEL 4 4 3/4" x 10'-0"Lg. COPPER CLAD DRIVEN GROUND ROD. EXOTHERMIC WELD OR UNDERGROUND APPROVED LUG CONNECT CONDUCTOR TO RODS. COLD WATER PIPE GROUND TO WITHIN 5'-0" OF WATER SERVICE ENTRANCE. IF WATER PIPING IS PVC THEN INSTALL A SECOND GROUND ROD. UFER GROUND MINIMUM OF 20'-0" ENCASED IN NEW RESTROOM CONCRETE IN DIRECT CONTACT WITH EARTH. I sca=33,400 4 3 1 1 2 FEEDER SCHEDULE (4 #3/0 XHHW CU) 2 1/2" PVC (1 #6 S.D.B.C.) 1/2"C (1 #1 THWN CU & 1#8 GND) 2" PVC 5 6 7 (4 #250 KCMIL THWN CU & 1#4 GND) 3" PVC (3 #3 THWN CU & 1#8 GND) 1 1/4" PVC (4 #1/0 THWN CU & 1 #6GND) 2" PVC 3 WP M 100A -3P T 2 70A -3P NORTH RESTROOM PANEL 'LP2' 208Y/120V-3Ø-4W NORTH RESTROOM/BMX HIGH PANEL 'HP2' 480Y/277V-3Ø-4W, SERVICE ENTRANCE RATED (2) 3-POLE EQUIPPED SPACES BMX TRACK PANEL 'LP3' 208Y/120V-3Ø-4W PANEL 'LP2' PANEL 'LP3' 3 WP WP (1 #2 S.D.B.C.) 1"C 11 7 3/4" x 10'-0"Lg. COPPER CLAD DRIVEN GROUND ROD. EXOTHERMIC WELD OR UNDERGROUND APPROVED LUG CONNECT CONDUCTOR TO ROD. (TYPICAL) 200A -3P FRS- 5 5 3/4" x 10'-0"Lg. COPPER CLAD DRIVEN GROUND ROD. EXOTHERMIC WELD OR UNDERGROUND APPROVED LUG CONNECT CONDUCTOR TO RODS. COLD WATER PIPE GROUND TO WITHIN 5'-0" OF WATER SERVICE ENTRANCE. IF WATER PIPING IS PVC THEN INSTALL A SECOND GROUND ROD. UFER GROUND MINIMUM OF 20'-0" ENCASED IN NEW RESTROOM CONCRETE IN DIRECT CONTACT WITH EARTH. 4 3 1 1 2 FEEDER SCHEDULE (4 #350 KCMIL XHHW CU) 3" PVC (1 #6 S.D.B.C.) 1/2"C SOUTH RESTROOM LOW PANEL 'LP1' 208Y/120V-3Ø-4W, SERVICE ENTRANCE RATED 4 WP (1 #2 S.D.B.C.) 1"C 2 10 #10 THWN CU) 1"C T 208Y/120V-3Ø-4W SEC. UTILITY PAD MOUNTED TRANSFORMER ESTIMATED TO BE (150 KVA). COORDINATE WITH FORT COLLINS LIGHT AND POWER (FCL&P) FOR EXACT SOURCE LOCATION AND TYPE. COIL 5'-0" OF CONDUCTORS AT SOURCE FOR FINAL CONNECTION BY FCL&P FORCES. WP PANEL 'LP1' I sca=26,000 1 3 WP M WP CT ENCLOSURE AND METER HOUSING TO FCL&P SPECIFICATIONS 5 (4 #350 KCMIL XHHW CU) 3" C 1 M CT CABINET SCHEDULE 40 PVC CONDUIT IN EARTH 24" MIN. (TYP.) GALVANIZED RIGID CONDUIT EXPOSED TRANSITION FROM PVC IN EARTH TO Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents PANEL SCHEDULES 1 OF 2 LE-19 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents PANEL SCHEDULES 2 OF 2 LE-20 GRC PRIOR TO EXPOSED ABOVE GRADE. TYPICAL FOR ALL IN EARTH CONDUITS. SERVICE LATERAL INCOMING FEEDER PANEL 'LP1' INSIDE STORAGE ROOM GROUND CONDUCTOR TO COLD WATER PIPE LUG WITHIN 5'-0" OF WATER PIPE ENTRANCE. SERVICE ENTRANCE FEEDER THROUGH WALL TO LP1 INSIDE STORAGE ROOM. Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents ELECTRICAL ONE-LINES LE-18 ONE-LINE DIAGRAM SOUTH RESTROOM ' LP1' LE18 SCALE: NOT TO SCALE 2 PANEL 'LP1' NORTH WALL ELEVATION LE18 SCALE: NOT TO SCALE 1 R-200 2 2 2 METER DISCONNECT TO BE TAB LOCKABLE BY FCL&P THIS IS NOT THE SERVICE DISCONNECT. 5 100A -3P 5 6 T 2 7 100A -3P 7 8 45kVA 'TLP3' 75kVA 'TLP2' FRS- R-100 FRS- R-70 8 (4 #3/0 XHHW CU & 1 #6GND) 2 1/2" PVC COIL A MINIMUM OF 5'-0" OF SERVICE LATERAL CONDUCTORS AT THE SAME TRANSFORMER AS 'HP1' FOR FINAL CONNECTION TO THE TRANSFORMER BY FCL&P FORCES METER DISCONNECT AND METER HOUSING TO FCL&P SPECIFICATIONS 1 5 4 8 9 10 6 250A MLO LABEL EACH BREAKER AS: "SERVICE MAIN BREAKER". MAXIMUM OF (6) HANDLES ALLOWABLE PER THE NEC. * * * * * 1 2 3 4 5 6 7 8 9 10 11 BOTH TRANSFORMERS ARE 480V-3Ø PRI AND 208Y/120V-3Ø-4W SEC. WP WP PANEL 'HP2' M PANEL 'LP2' INSIDE STORAGE ROOM TRANSFORMER 'TLP2' INSIDE STORAGE ROOM METER FUSIBLE DISCONNECT GROUND CONDUCTOR TO COLD WATER PIPE LUG. SCHEDULE 40 PVC CONDUIT IN EARTH 24" MIN. (TYP.) GALVANIZED RIGID CONDUIT EXPOSED TRANSITION FROM PVC IN EARTH TO GRC PRIOR TO EXPOSED ABOVE GRADE. TYPICAL FOR ALL IN EARTH CONDUITS. GROUND CONDUCTOR TO UFER CONCRETE ENCASED ELECTRODE. TRANSFORMER GROUND CONDUCTOR TO GROUND ROD INSIDE STORAGE ROOM. SERVICE LATERAL INCOMING FEEDER GROUND CONDUCTOR TO GROUND ROD FOR SERVICE ENTRANCE BONDING. BRANCH FEEDER TO LP3 VIA TLP3 TRANSFORMER AT BMX TRACK ANNOUNCER'S BOOTH TLP2 DISCONNECT INSIDE STORAGE ROOM. Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents ELECTRICAL ONE-LINES LE-17 ONE-LINE DIAGRAM NORTH RESTROOM/BMX TRACK 'HP2' LE17 SCALE: NOT TO SCALE 2 PANEL 'HP2' EAST WALL ELEVATION LE17 SCALE: NOT TO SCALE 1 'BF1' PANEL 'BF2' BALL FIELD LOW PANEL-1 'BFL1' 208Y/120V-3Ø-4W MINI POWER ZONE W/15kVA TRANSFORMER 480V-3Ø PRI - 208Y/120V-3Ø-4W SEC PANEL 'BF1' 2 WP WP WP WP 20A -3P (1 #1/0 S.D.B.C.) 1"C 4 2 3 3/4" x 10'-0"Lg. COPPER CLAD DRIVEN GROUND ROD. EXOTHERMIC WELD OR UNDERGROUND APPROVED LUG CONNECT CONDUCTOR TO ROD. 1 CT ENCLOSURE AND METER HOUSING TO FCL&P SPECIFICATIONS LABEL EACH BREAKER AS: "SERVICE MAIN BREAKER". MAXIMUM OF (6) HANDLES ALLOWABLE PER THE NEC. * * * * * 5 1 2 3 4 5 PANEL 'HP1' M CT CABINET SCHEDULE 40 PVC CONDUIT IN EARTH 24" MIN. (TYP.) GALVANIZED RIGID CONDUIT EXPOSED TRANSITION FROM PVC IN EARTH TO GRC PRIOR TO EXPOSED ABOVE GRADE. TYPICAL FOR ALL IN EARTH CONDUITS. SERVICE LATERAL INCOMING FEEDER GROUND CONDUCTOR TO GROUND RODS FOR SERVICE ENTRANCE BONDING. MINIMUM 8'-0" APART GROUND CONDUCTOR TO UFER CONCRETE ENCASED ELECTRODE. Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents ELECTRICAL ONE-LINES LE-16 ONE-LINE DIAGRAM NORTH BALL FIELDS LIGHTING 'HP1' LE16 SCALE: NOT TO SCALE 2 PANEL 'HP1' WEST WALL ELEVATION LE16 SCALE: NOT TO SCALE 1 Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents LIGHTING DETAILS LE-15 TYPE 'T' LUMINAIRE DETAIL LE15 SCALE: NOT TO SCALE 4 TYPE 'T' LUMINAIRE ELEVATION LE15 SCALE: 1/2" = 1'-0" 1 TYPE 'L1' SIGN WALL DETAIL/SECTION LE15 SCALE: 3/4" = 1'-0" 3 TYPE 'M' OR 'M1' GREEN SCREEN DETAIL LE15 SCALE: 3/4" = 1'-0" 2 DETAILS SILO WALL LIGHT BOX, SEE SILO DRAWING TYPE "LT" TRANSFORMERS MOUNT AT 5' 120 VOLT POWER AND CONDUIT WET LOCATION J-BOX RECESSED INTO STRUCTURAL MEMBER. TYPE "G" LUMINAIRE TO 120 VOLT POWER STRUCTURAL MEMBER GIRTER Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents BARN LIGHTING PLAN BARN LIGHTING FLOOR PLAN LE14 SCALE: NOT TO SCALE 1 LE-14 BARN LIGHTING ELEVATIONS LE14 SCALE: NOT TO SCALE 2 TYPE "L" LUMINAIRE DEAIL LE14 SCALE: NOT TO SCALE 3 TYPE "G" LUMINAIRE DEAIL LE14 SCALE: NOT TO SCALE 4 LUMINAIRE. HOLE CUT IN STEEL PLATE TO ACCOMMODATE LUMINAIRE. TYPE 'RT' REMOTE TRANSFORMER IN WET LOCATION ENCLOSURE 120 VOLT POWER IN Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents FARM HOUSE LIGHTING FLOOR PLAN LE13 SCALE: NOT TO SCALE 1 FARM HOUSE LIGHTING ELEVATION LE13 SCALE: NOT TO SCALE 2 FARMHOUSE LTG PLAN LE-13 TYPE "P" & "P1" ORIENTATION DETAIL LE13 SCALE: NOT TO SCALE 3 TYPE "R" MOUNTING DETAIL LE13 SCALE: NOT TO SCALE 4 LP2-14,16,18 (3#6 THWN CU & 1#10 GND) 1" C. TO TO TO LP1-7 OR LP2-7 15KW LP1-1 OR LP2-1 LP1-17 OR LP2-17 LP1-19 OR LP2-19 LP1-8,10,12 OR LP2-8,10,12 (3#6 THWN CU & 1#10 GND) 1" C. LP1-2,4,6 OR LP2-2,4,6 (3#8 THWN CU & 1#10 GND) 3/4" C. EUH-2 EUH-1 10KW LP1-13 OR LP2-13 LOWER PANEL 'LP1' OR 'LP2' 208Y/120V-3Ø-4W TLP2 FOR LP2 ONLY MOTOR FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR, ELECTRICAL CONTRACTOR TO PROVIDE CONTROLS. WIRE TICKS: NEUTRAL, HOT, SWITCH LEG, AND GROUND RESPECTIVELY. TOGGLE SWITCH WITH THERMAL OVERLOADS. WALL SWITCH. THERMOSTAT BY MECHANICAL CONTRACTOR, ELECTRICAL CONTRACTOR TO INSTALL. REMOTE SENSOR BY MECHANICAL CONTRACTOR, ELECTRICAL CONTRACTOR TO INSTALL. OCCUPANCY SENSOR FOR ON/OFF CONTROL OF EXHAUST FAN. ELECTRICAL HAND DRYER. ELECTRIC WATER HEATER FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR AND POWERED BY ELECTRICAL CONTRACTOR. ELECTRICAL UNIT HEATER FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR AND POWERED BY ELECTRICAL CONTRACTOR. GFCI DUPLEX RECEPTACLE. POWER PANEL. FUSIBLE DISCONNECT SWITCH. NEW WALL MOUNTED TRANSFORMER. 30A 12-POLE ELECTRICALLY HELP LIGHTING CONTACTOR ENCLOSURE WITH HOA SELECTOR GFI SWITCH, PC ON/OFF CONTROLLED WHEN SWITCH IS IN AUTO POSITION. WALL MOUNTED PHOTOCELL. GFI ELECTRICAL LEGEND T1A T1B T PROVIDE FOR LP2 ONLY LC PC LC LP1-20,22,24,26, 28,30,32,34 (16#10 THWN CU & 1#10 GND) 2" C. GFI WP GFI WP Scale: 1" = 40' 0 10 20 30 40 80 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents SITE LIGHTING PLAN LE-12 ENLARGED ELECTRICAL RESTROOM LAYOUT (TYPICAL). LE12 SCALE: 1 TYPICAL RESTROOM LIGHTING PLAN SCALE: 3" = 1'-0" TYPICAL RESTROOM POWER PLAN SCALE: 3" = 1'-0" Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents SITE LIGHTING PLAN SITE LIGHTING PLAN LE11 SCALE: 1" = 40' 1 LE-11 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents SITE LIGHTING PLAN SITE LIGHTING PLAN LE10 SCALE: 1" = 40' 1 LE-10 (2#10THWN CU & 1#10GND) 1"PVC FUTURE ART LIGHTING Scale: 1" = 40' 0 10 20 30 40 80 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents SITE LIGHTING PLAN SITE LIGHTING PLAN LE09 SCALE: 1" = 40' 1 LE-09 SEE RESTROOM DETAIL 1 ON LE12. SEE DETAIL 1 ON LE13 FOR BARN LUMINAIRE LAYOUT. 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents SITE LIGHTING PLAN SITE LIGHTING PLAN LE08 SCALE: 1" = 40' 1 LE-08 SEE DETAIL DETAIL 1 ON LE13 FOR FARM HOUSE LUMINAIRE LAYOUT. SEE DETAIL DETAIL 3 ON LE15 FOR ENLARGED SIGN DETAIL. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents SITE LIGHTING PLAN SITE LIGHTING PLAN LE07 SCALE: 1" = 40' 1 ENLARGED HARVEST ROOM PLAN LE-07 LE07 SCALE: 1" = 10' 1 2 LE15 1#10 GND) 1" PVC T WP WP WP Scale: 1" = 40' 0 10 20 30 40 80 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents SITE LIGHTING PLAN SITE LIGHTING PLAN LE06 SCALE: 1" = 40' 1 LE-06 BMX TRACK PANEL 'LP3' 208Y/120V-3Ø-4W SEE PLAN 2/LE06 FOR ENLARGED PLAN. ENLARGED BMX TRACK ANNOUNCERS BOOTH PLAN LE06 SCALE: 1" = 10' 2 WP GFI BF2-2,4,6 (3#10 THWN CU & 1#10 GND) 1" PVC BFL1-6 (2#12 THWN CU & 1#12 GND) 3/4" PVC BF2-1,3,5 (3#10 THWN CU & 1#10 GND) 1" PVC BF2-7,9,11 (3#8 THWN CU & 1#8 GND) 1" PVC BF2-13,15,17 (3#6 THWN CU & 1#6 GND) 1" PVC BF2-8,10,12 (3#8 THWN CU & 1#8 GND) 1" PVC BF2-14,16,18 (3#6 THWN CU & 1#6 GND) 1" PVC B4 A4 A3 B3 C3 C4 LS13 22 T M T CT M UTILITY PAD MOUNTED TRANSFORMER BY FCL&P BMX TRACK ANNOUNCER'S BOOTH REFER TO LANDSCAPE PLANS FOR BOOTH LOCATION PANEL 'LP2' 208Y/120V-3Ø-4W PANEL 'HP1' 480Y/277V-3Ø-4W PANEL 'LP3' 208Y/120V-3Ø-4W WP WP WP 1#10 GND) 1" PVC GFI 13 11 F BFL1-11,13 (4#12 THWN CU & 1#12 GND) 3/4" PVC 2" PVC TO SCOREBOARD M T CT M WP WP WP S cale: 1" = 40' 0 10 20 30 40 80 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents SITE LIGHTING PLAN SITE LIGHTING PLAN LE05 SCALE: 1" = 40' 1 LE-05 SEE ENLARGED RESTROOM ENLARGED PLAN 3/LE05. ANNOUNCER'S BOOTH ELECTRICAL PLAN LE05 SCALE: NOT TO SCALE. 2 SEE PLAN 2/LE05 FOR ENLARGED PLAN. EAST BALL FIELD PANEL-2 'BF2' 480Y/277-3Ø-4W LP2-20,22 (4#10 THWN CU & 1#10 GND) 1"PVC BALL FIELD HIGH PANEL 'HP1' 480Y/277V-3Ø-4W RESTROOM LOWER PANEL-2 'LP2' 208Y/120V-3Ø-4W TLP2 208Y/120V-3Ø-4W RESTROOM HIGH PANEL 'HP2' 480Y/277V-3Ø-4W ENLARGED NORTH RESTROOM PANEL LAYOUT LE05 SCALE: 1" = 10'-0". 3 PANEL 'HP2' 480Y/277V-3Ø-4W 1#10 GND) 1" PVC LS09 22 LS10 20 LS11 20 LS12 22 BF2-2,4,6 (3#10 THWN CU & 1#10 GND) 1" PVC BF2-8,10,12 (3#8 THWN CU & 1#8 GND) 1" PVC BF2-14,16,18 (3#6 THWN CU & 1#6 GND) 1" PVC B4 A4 GFI 7 F 9 BFL1-7,9 (4#12 THWN CU & 1#12 GND) 3/4" PVC 2" PVC TO SCOREBOARD Scale: 1" = 40' 0 10 20 30 40 80 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents SITE LIGHTING PLAN SITE LIGHTING PLAN LE04 SCALE: 1" = 40' 1 LE-04 ANNOUNCER'S BOOTH ELECTRICAL PLAN LE04 SCALE: NOT TO SCALE. 2 SEE PLAN 2/LE04 FOR ENLARGED PLAN. WEST BALL FIELD PANEL 'BF1' 480Y/277V-3Ø-4W BALL FIELD LOW PANEL 'BFL1' 208Y/120V-3Ø-4W 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents SITE LIGHTING PLAN SITE LIGHTING PLAN LE03 SCALE: 1" = 40' 1 LE-03 lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents SITE LIGHTING PLAN LE-02 SITE LIGHTING PLAN LE02 SCALE: 1" = 40' 1 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents LIGHTING LEGEND LE-01 SOUTHEAST COMMUNITY PARK Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 TB DR Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 90% CONSTRUCTION DOCUMENTS Drawing Name: lighting design and engineering 07.21.2015 75% Construction Documents 12.04.2015 90% Construction Documents 02.09.2016 95% Construction Documents LIGHTING COVER SHEET LE-00 LIGHTING PLAN SHEET INDEX LE02 LE03 LE04 LE05 LE06 LE07 LE08 LE09 LE10 LE11