Loading...
HomeMy WebLinkAboutBROOKVIEW APARTMENTS - PDP - PDP160003 - SUBMITTAL DOCUMENTS - ROUND 1 - ELEVATIONSMAIN LEVEL 100' - 0" 2nd LEVEL 110' - 1 3/4" 3rdLEVEL 3rd LEVEL 120' - 3 1/2" ROOF BEARING 128' - 4 5/8" 28' - 3 1/2" 27' - 7 1/4" VERTICAL BOARD & BATTEN SIDING STUCCO HORIZONTAL LAP SIDING ASPHALT SHINGLE ROOFING GABLE ATTIC VENT MAIN LEVEL 100' - 0" 2nd LEVEL 110' - 1 3/4" 3rdLEVEL 3rd LEVEL 120' - 3 1/2" ROOF BEARING 128' - 4 5/8" 27' - 7 1/4" 29' - 7 1/4" 28' - 5 1/4" 29' - 7 1/4" VERTICAL BOARD & BATTEN SIDING STUCCO HORIZONTAL LAP SIDING ASPHALT SHINGLE ROOFING 39' - 9 5/8" GABLE ATTIC VENT 401 West Mountain Avenue, Suite 100 Fort Collins, CO 80521 ph: 970.224.1191 www.theartofconstruction.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARCHITECTS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. CHECKED BY: DRAWN BY: COPYRIGHT: Issued No. Description Date 1 01-06-2016 Revisions 2 3 4 5 6 No. Description Date VAUGHT FRYE LARSON architects PRELIMINARY DESIGN REVIEW 1/6/2016 8:56:53 AM MAIN LEVEL 100' - 0" 2nd LEVEL 110' - 1 3/4" 3rdLEVEL 3rd LEVEL 120' - 3 1/2" ROOF BEARING 128' - 4 5/8" 28' - 3 1/2" 27' - 7 1/4" 29' - 7 1/2" STUCCO HORIZONTAL LAP SIDING ASPHALT SHINGLE ROOFING GABLE ATTIC VENT MAIN LEVEL 100' - 0" 2nd LEVEL 110' - 1 3/4" 3rdLEVEL 3rd LEVEL 120' - 3 1/2" ROOF BEARING 128' - 4 5/8" 28' - 5 1/2" 27' - 7 1/4" 29' - 7 1/2" 28' - 9 1/4" STUCCO HORIZONTAL LAP SIDING ASPHALT SHINGLE ROOFING GABLE ATTIC VENT 401 West Mountain Avenue, Suite 100 Fort Collins, CO 80521 ph: 970.224.1191 www.theartofconstruction.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARCHITECTS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. CHECKED BY: DRAWN BY: COPYRIGHT: Issued No. Description Date 1 01-06-2016 Revisions 2 3 4 5 6 No. Description Date VAUGHT FRYE LARSON architects PRELIMINARY DESIGN REVIEW 1/6/2016 8:57:03 AM 1/6/2016 8:57:03 AM G:\2015\15-05 Brookview Apartments\4 Revit\Brookview Apartments.rvt PREFINISHED METAL COPING STUCCO 6" BUILT-UP STUCCO BAND 1111 A3 PREFINISHED METAL COPING STUCCO 6" BUILT-UP STUCCO BAND 6" PIPE BOLLARD, TYP. PREFINISHED METAL COPING STUCCO 6" PIPE BOLLARD, TYP. 6" BUILT-UP STUCCO BAND STEEL GATE, PAINT PREFINISHED METAL COPING STUCCO 6" PIPE BOLLARD, TYP. 6" BUILT-UP STUCCO BAND 13' - 4" 8" 7' - 4" 8" 8" 8" 10' - 8" 8" 8" 8' - 8" 1111 A3 PIPE BOLLARD STEEL GATE PREFINISHED METAL CAP FLASHING P.T. 2X WOOD BLOCKING ANCHORED INTO CMU 8"X8"X16" CMU, FILL CELLS SOLID BOND BM. w/ (2)#5 CONT. REINF. #5 VERT. @ 32" O.C. FULLY GROUT REINFORCED CELLS #6 VERT DOWELS @ 48" O.C. EXTEND 2'- 6" INTO CMU PORTLAND CEMENT STUCCO SYSTEM w/ SYNTHETIC FINISH COAT HORIZ. REINF. AT 16" O.C. 8" PAINT INT. FACE OF CMU 3' - 0" 5' - 4" CONC. FOUND. WALL. REINF. W/ 2-#4 T&B 3 #5 CONT. T&B 1' - 0" 2' - 8" #4 @ 32" O.C. TRANSVERSE T&B T.FRONTT.O. SLAB @ FRONT RECIVIL RE CIVIL 6" CONCRETE SLAB WITH 6X6 10-10 WWF REINFORCING. SLOPE TO FRONT CONTIN. 6" BUILT-UP STUCCO BAND COMPRESSIBLE FILLER CAPPED W/ SEALANT ANCHOR INTO CMU. 3 1/2 X 6 X 5/16" GALV. STL. ANGLE FULL HT. @ JAMBS. #6 VERT. @ 48" O.C. PIVOT 4X4X1/4 STL. TUBE GATE POST FILLED W/ CONC. PAINTED STEEL GATE FILL ALL CELLS SOLID 3" 6" PIPE BOLLARD EXPANSION JOINT W/ SEALANT & FILLER MATERIAL 1'-4" DIA. CONCRETE BASE - TROWEL TOP SURFACE 6" DIAMETER STEEL PIPE DOMED CONCRETE CAP CENTER LINE OF BOLLARD PAVING RE: CIVIL NOTE: PAINT FINISH TO BE SAFETY YELLOW 4' - 0" 4" 3' - 6" 1. 401 West Mountain Avenue, Suite 100 Fort Collins, CO 80521 ph: 970.224.1191 www.theartofconstruction.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARCHITECTS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. CHECKED BY: DRAWN BY: COPYRIGHT: Issued No. Description Date 1 01-06-2016 Revisions 2 3 4 5 6 No. Description Date VAUGHT FRYE LARSON architects PRELIMINARY DESIGN REVIEW 1/6/2016 8:57:04 AM 1/6/2016 8:57:04 AM G:\2015\15-05 Brookview Apartments\4 Revit\Brookview Apartments.rvt A3 TRASH ENCLOSURE BROOKVIEW APTS FORT COLLINS PRELIMINARY DESIGN REVIEW 2015-05 TM FV 5 1/4" = 1'-0" WEST ELEVATION 6 1/4" = 1'-0" NORTH ELEVATION 3 1/4" = 1'-0" EAST ELEVATION 4 1/4" = 1'-0" SOUTH ELEVATION 2 1/4" = 1'-0" TRASH ENCLOSURE - PLAN 1 3/4" = 1'-0" TRASH ENCLOSURE - SECTION 8 1 1/2" = 1'-0" TRASH ENCLOSURE HINGE DETAIL 7 3/4" = 1'-0" PIPE BOLLARD DETAIL A2 EXTERIOR ELEVATIONS BROOKVIEW APTS FORT COLLINS PRELIMINARY DESIGN REVIEW 2015-05 TM FV 1 1/8" = 1'-0" NORTH ELEVATION 2 1/8" = 1'-0" SOUTH ELEVATION 1/6/2016 8:56:53 AM G:\2015\15-05 Brookview Apartments\4 Revit\Brookview Apartments.rvt A1 EXTERIOR ELEVATIONS BROOKVIEW APTS FORT COLLINS PRELIMINARY DESIGN REVIEW 2015-05 TM FV 1 1/8" = 1'-0" EAST ELEVATION 2 1/8" = 1'-0" WEST ELEVATION