Loading...
HomeMy WebLinkAboutCAPSTONE COTTAGES - FDP - FDP150046 - SUBMITTAL DOCUMENTS - ROUND 1 - ELEVATIONS12 4 8'-7" WIN. H.H. 7'-7" WIN. H.H. CJ CJ 7'-6" WIN. H.H. 2'-0" 2'-0" TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR CJ CJ WIN. H.H. @ 8'-7" WIN. H.H. @ 7'-7" 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" 6:12 SLOPE 6:12 SLOPE 4 12 4 C A A 38'-1 1/4" TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" WIN. H.H. @ 8'-7" WIN. H.H. @ 7'-7" DOOR/WIN. H.H. @ 6'-9" TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" WIN. H.H. @ 8'-7" WIN. H.H. @ 7'-7" 4:12 SLOPE 12 4 8'-7" WIN. H.H. 7'-7" WIN. H.H. CJ CJ 7'-6" WIN. H.H. 2'-0" 2'-0" CJ CJ 6:12 SLOPE 6:12 SLOPE 4 12 4 C A A 38'-1 1/4" 2'-0" 6:12 SLOPE TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" 2'-0" WIN. H.H. @ 8'-7" TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" WIN. H.H. @ 7'-7" WIN. H.H. @ 7'-7" WIN. H.H. @ 7'-6" TOP OF PLATE @ DORMER 3'-8" CJ CJ 6 12 6 12 6:12 6:12 SLOPE 4 12 6:12 6:12 4 C A A 1 TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" 4 12 TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" WIN. H.H. @ 7'-7" WIN. H.H. @ 7'-7" TOP OF PLATE @ DORMER 3'-8" CJ CJ 6 12 6 12 6:12 SLOPE 4 12 6:12 6:12 6:12 4:12 SLOPE 4 C A A 1 4 12 6 12 6 12 6:12 SLOPE 6 12 6 12 6 12 6 12 TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE CJ CJ 6 12 6 12 6:12 6:12 SLOPE TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" WIN. H.H. @ 7'-7" WIN. H.H. @ 7'-7" WIN. H.H. @ 7'-6" 6:12 4 12 TOP OF PLATE @ DORMER 3'-8" 6:12 4 C A A 1 38'-3" TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" 4 TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" WIN. H.H. @ 7'-7" WIN. H.H. @ 7'-7" TOP OF PLATE @ DORMER 3'-8" 6 12 6 12 6:12 SLOPE 4 12 6:12 6:12 6:12 6'-9" DOOR H.H. 4:12 SLOPE 4 C A A 1 38'-3" 4 12 6 12 6 12 6 12 6 12 TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" 4 12 4 12 PORCH BEARING @ 8'-4" 7'-7" WIN. H.H. 7'-7" WIN. H.H. CJ CJ 7'-6" WIN. H.H. TOP OF PLATE @ DORMER 3'-6" 12 4 2'-0" 2'-0" 12 8 12 4 8:12 SLOPE 3'-6" 6:12 12 6 6 4 17 C A A 41'-41 4" H TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 4 12 4 12 7'-7" WIN. H.H. 7'-7" WIN. H.H. CJ CJ 7'-6" WIN. H.H. TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" PORCH BEARING @ 8'-4" 12 4 12 8 12 4 8:12 SLOPE TOP OF PLATE @ DORMER 3'-6" 4:12 SLOPE 6:12 12 6 6 4 A B 15 H A A 41'-41 4" C CJ J CJ TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR 4 12 4 12 7'-7" WIN. H.H. 7'-7" WIN. H.H. CJ CJ 7'-6" WIN. H.H. 3'-6" 12 6 12 4 12 6 12 4 2'-0" 6:12 SLOPE TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" TOP OF PLATE @ DORMER 3'-6" 2'-0" PORCH BEARING @ 8'-4" 4:12 SLOPE 4 12 6 A A C 38'-51 2" H TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE 4 12 4 12 7'-7" WIN. H.H. 7'-7" WIN. H.H. CJ CJ 7'-6" WIN. H.H. 3'-6" 12 6 12 4 12 6 12 4 2'-0" 6:12 SLOPE 2'-0" TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" TOP OF PLATE @ DORMER 3'-6" PORCH BEARING @ 8'-4" 4:12 SLOPE 6 C A A 12 6 4:12 SLOPE 38'-51 2" 12 6 12 4 12 4 12 6 TOP OF PLATE 4 12 4 12 7'-7" WIN. H.H. 7'-7" WIN. H.H. CJ CJ 7'-6" WIN. H.H. 3'-6" 12 6 12 4 12 6 12 4 2'-0" 6:12 SLOPE TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" TOP OF PLATE @ DORMER 3'-6" 2'-0" PORCH BEARING @ 8'-4" 4:12 SLOPE 12 6 4 C A A 38'-51 2" H TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE 4 12 4 12 7'-7" WIN. H.H. 7'-7" WIN. H.H. CJ CJ 7'-6" WIN. H.H. 3'-6" 12 6 12 4 12 6 12 4 2'-0" 6:12 SLOPE 2'-0" TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" TOP OF PLATE @ DORMER 3'-6" PORCH BEARING @ 8'-4" 4:12 SLOPE 12 6 4:12 SLOPE C A A 38'-51 2" 6 12 6 12 4 12 4 12 6 TOP OF PLATE 9 9 9 35'-6" 1 4 6 6 4 Vinyl window unit Painted SmartSide Casing Painted Solid Timber Bracket 1 4 6 14 TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 35'-6" 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" Vinyl window unit Painted SmartSide Casing Painted Solid Timber Bracket 1 A2-0 FRONT ELEVATION 3/16" = 1'-0" GENERAL NOTE: - Use high temp modified bitumen underlayment around roof penetrations, in keeping with underlayment manufacturer's recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. -Use high temp modified bitumen underlayment at penetrations, typ. - Use non-corrosive fasteners and use of elastomeric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. 1 4 6 TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 35'-6" 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" Vinyl window unit Painted SmartSide Casing Painted Solid Timber Bracket TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1 4 6 14 35'-6" 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" Vinyl window unit Painted SmartSide Casing Painted Solid Timber Bracket 1 A2-1 BACK ELEVATION 3/16" = 1'-0" GENERAL NOTE: - Use high temp modified bitumen underlayment around roof penetrations, in keeping with underlayment manufacturer's 9 9 9 35'-6" Vinyl window unit Painted SmartSide Casing Painted Solid Timber Bracket 1 4 6 35'-6" 9'-0" 1'-2 3 4" 1'-2 3 4" 9'-0" 9'-0" 1 4 6 14 Vinyl window unit Painted SmartSide Casing Painted Solid Timber Bracket 1 A2-0 FRONT ELEVATION 3/16" = 1'-0" GENERAL NOTE: - Use high temp modified bitumen underlayment around roof penetrations, in keeping with underlayment manufacturer's recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. -Use high temp modified bitumen underlayment at penetrations, typ. - Use non-corrosive fasteners and use of elastomeric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 7" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES SIMULATED STONE VENEER 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL 35'-6" 1 4 6 Vinyl window unit Painted SmartSide Casing Painted Solid Timber Bracket 35'-6" 9'-0" 9'-0" 9'-0" 14 1'-23 4" 1'-2 3 4" Painted Solid Timber Bracket Vinyl window unit Painted SmartSide Casing Painted Solid Timber Bracket 1 4 6 1 A2-1 BACK ELEVATION 3/16" = 1'-0" GENERAL NOTE: - Use high temp modified bitumen underlayment around roof penetrations, in keeping with underlayment manufacturer's recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. -Use high temp modified bitumen underlayment at penetrations, typ. - Use non-corrosive fasteners and use of elastomeric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 7" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES SIMULATED STONE VENEER 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF SLAB @ MAIN LEVEL TOP OF PLATE @ 1ST FLOOR 9'-0" 1'-2 3 4" 8'-0" WIN. H.H. 7'-0" WIN. H.H. 6:12 SLOPE 8'-0" WIN. H.H. 4 1 6 4 12 14 4:12 SLOPE TOP OF PLATE @ PORCH 8'-6" 12 6 12 6 16 9 26'-5" TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL 1'-23 4" 9'-0" 1 1 6 4 DRYER VENT LOCATION 7'-6" SHUTTER H.H. 12 4 4 11 14 15 12 6 12 6 8'-6" TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL 1'-23 4" 9'-0" 1 4 WIN. H.H @ 7'-0" 6'-8" DOOR H.H. 12 14 15 4:12 SLOPE 9 25'-3" TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL 1'-23 4" 9'-0" 12 4 1 4 4 DRYER VENT LOCATION 8'-0" SHUTTER H.H. 8 7'-6" WIN. H.H. 11 14 15 12 4 4:12 SLOPE 6 12 4 16 25'-3" 1 TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR 9 7'-6" WIN. H.H. TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ 1ST FLOOR 1'-23 4" 9'-0" 27'-3" 8:12 SLOPE 6'-8" DOOR H.H. 3:12 SLOPE 1 4 11 6 14 16 TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ 1ST FLOOR 1'-23 4" 9'-0" 12 3 1 4 4 7'-6" WIN. H.H. 7'-6" WIN. H.H. 11 14 12 8 6:12 SLOPE 6 12 6 16 14 27'-3" 16 E E 12 8 TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" 9 7'-6" WIN. H.H. TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ 1ST FLOOR 1'-23 4" 9'-0" 27'-3" 8:12 SLOPE 6'-8" DOOR H.H. 1 4 11 6 14 16 12 8 12 8 7'-6" WIN. H.H. 4:12 SLOPE 8:12 SLOPE TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ 1ST FLOOR 1'-23 4" 9'-0" 1 4 4 7'-6" WIN. H.H. 7'-6" WIN. H.H. 11 14 12 8 6 12 6 16 14 27'-3" 16 E E 12 8 4 9 7'-6" WIN. H.H. TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ 1ST FLOOR 1'-23 4" 9'-0" 8:12 SLOPE 6'-8" DOOR H.H. 1 4 11 6 14 16 7'-6" WIN. H.H. 4:12 SLOPE 8:12 SLOPE TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ 1ST FLOOR 1'-23 4" 9'-0" 1 4 4 7'-6" WIN. H.H. 7'-6" WIN. H.H. 11 14 12 8 6 12 6 16 14 27'-3" 16 E E 12 8 4 4:12 SLOPE TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" 9 7'-6" WIN. H.H. TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ 1ST FLOOR 1'-23 4" 9'-0" 27'-3" 6'-8" DOOR H.H. 1 4 11 6 14 16 TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ 1ST FLOOR 12 3 1 4 4 7'-6" WIN. H.H. 7'-6" WIN. H.H. 11 14 12 8 6:12 SLOPE 6 12 6 14 16 E 12 8 1 A2-1 FRONT ELEVATION 1/4" = 1'-0" 2 A2-1 LEFT SIDE ELEVATION 1/4" = 1'-0" EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 6" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ 1ST FLOOR 1'-23 4" 9'-0" 12 3 1 4 4 7'-6" WIN. H.H. 7'-6" WIN. H.H. 11 14 12 8 6:12 SLOPE 6 12 6 14 27'-3" 16 E 12 8 6'-9" WIN. H.H. DRYER VENT LOCATION 15 6:12 SLOPE TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ 1ST FLOOR 1'-23 4" 9'-0" 27'-3" 7'-6" WIN. H.H. 7'-6" WIN. H.H. 8:12 SLOPE 1 4 4 11 6 16 2 A2-2 RIGHT SIDE ELEVATION 1/4" = 1'-0" 1 A2-2 REAR ELEVATION 1/4" = 1'-0" EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 6" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES 3 COAT STUCCO SYSTEM 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 GENERAL NOTE: - Use modified bitumen (High Temp) underlayment along eaves, and slope transitions, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. - Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES 3 COAT STUCCO SYSTEM 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 GENERAL NOTE: - Use modified bitumen (High Temp) underlayment along eaves, and slope transitions, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. - Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ 1ST FLOOR 1'-23 4" 9'-0" 12 3 1 4 4 7'-6" WIN. H.H. 7'-6" WIN. H.H. 11 14 12 8 6 12 6 16 14 27'-3" 16 E E 12 8 4 4:12 SLOPE 6'-9" WIN. H.H. DRYER VENT LOCATION 15 6:12 SLOPE TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ 1ST FLOOR 1'-23 4" 9'-0" 27'-3" 7'-6" WIN. H.H. 7'-6" WIN. H.H. 8:12 SLOPE 1 4 4 11 6 16 1 A2-1 FRONT ELEVATION 1/4" = 1'-0" 2 A2-1 RIGHT SIDE ELEVATION 1/4" = 1'-0" 3 A2-1 REAR ELEVATION 1/4" = 1'-0" 4 A2-1 LEFT SIDE ELEVATION 1/4" = 1'-0" EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 6" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES 3 COAT STUCCO SYSTEM 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 GENERAL NOTE: - Use modified bitumen (High Temp) underlayment along eaves, and slope transitions, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. - Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term 4:12 SLOPE TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ 1ST FLOOR 1'-23 4" 9'-0" 12 3 1 4 4 7'-6" WIN. H.H. 7'-6" WIN. H.H. 11 14 12 8 6 12 6 16 14 27'-3" 16 E E 12 8 4 4:12 SLOPE 6'-9" WIN. H.H. DRYER VENT LOCATION 15 6:12 SLOPE TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ 1ST FLOOR 1'-23 4" 9'-0" 27'-3" 7'-6" WIN. H.H. 7'-6" WIN. H.H. 8:12 SLOPE 1 4 4 11 6 16 1 A2-1 FRONT ELEVATION 1/4" = 1'-0" 2 A2-1 RIGHT SIDE ELEVATION 1/4" = 1'-0" 3 A2-1 REAR ELEVATION 1/4" = 1'-0" 4 A2-1 LEFT SIDE ELEVATION 1/4" = 1'-0" EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 6" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES 3 COAT STUCCO SYSTEM 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 GENERAL NOTE: - Use modified bitumen (High Temp) underlayment along eaves, and slope transitions, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. - Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ 1ST FLOOR 1'-23 4" 9'-0" 12 3 1 4 4 7'-6" WIN. H.H. 8'-0" SHUTTER H.H. 11 14 6:12 SLOPE 6 12 6 16 14 27'-3" 16 E E 16 12 8 12 8 6'-9" WIN. H.H. DRYER VENT LOCATION 15 6:12 SLOPE TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ 1ST FLOOR 1'-23 4" 9'-0" 27'-3" 7'-6" WIN. H.H. 7'-6" WIN. H.H. 8:12 SLOPE 1 4 4 11 6 16 1 A2-1 FRONT ELEVATION 1/4" = 1'-0" 2 A2-1 RIGHT SIDE ELEVATION 1/4" = 1'-0" 3 A2-1 REAR ELEVATION 1/4" = 1'-0" 4 A2-1 LEFT SIDE ELEVATION 1/4" = 1'-0" EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 6" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES 3 COAT STUCCO SYSTEM 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 GENERAL NOTE: - Use modified bitumen (High Temp) underlayment along eaves, and slope transitions, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. - Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term TOP OF SLAB @ MAIN LEVEL 1'-23 4" 9'-0" 7'-6"SHUTTER H.H. 8'-0" SHUTTER H.H. 4 10'-0" 8 8 11 12 4 12 4 4:12 SLOPE 14 6 16 25'-3" 7'-0" WIN. H.H. 8'-0" WIN. H.H. 7'-0" WIN. H.H. TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL 1'-23 4" 9'-0" 7'-6" WIN. H.H. 1 4 15 15 11 15 4:12 SLOPE 12 4 12 4 6 6'-8" DOOR H.H. 4:12 SLOPE 16 25'-3" 1 A2-1 FRONT ELEVATION 1/4" = 1'-0" 2 A2-1 RIGHT SIDE ELEVATION 1/4" = 1'-0" 3 A2-1 REAR ELEVATION 1/4" = 1'-0" 4 A2-1 LEFT SIDE ELEVATION 1/4" = 1'-0" EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 6" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES 3 COAT STUCCO SYSTEM 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 GENERAL NOTE: - Use modified bitumen (High Temp) underlayment along eaves, and slope transitions, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. - Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term 12 4 6:12 TOP OF PLATE @ PORCH 6:12 SLOPE 16 26'-5" TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL 1'-23 4" 9'-0" 4 6 1 1 6:12 SLOPE 8'-0" SHUTTER H.H. 8'-0" SHUTTER H.H. 7'-0" SHUTTER H.H. 7'-0" SHUTTER H.H. 14'-0" 10'-0" 8'-0" 8 11 14 12 6 12 6 TOP OF PLATE @ PORCH TOP OF SLAB @ MAIN LEVEL 12 4 6:12 7'-0" WIN. H.H. 7'-0" WIN. H.H. 7'-0" WIN. H.H. TOP OF PLATE @ 2ND FLOOR TOP OF SUBFLOOR 9'-0" TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL 1'-23 4" 9'-0" 7'-0" WIN. H.H. 6:12 SLOPE 4 1 6 1 8 8 4:12 SLOPE 11 15 12 6 12 6 26'-5" 1 A2-1 FRONT ELEVATION 1/4" = 1'-0" 2 A2-1 RIGHT SIDE ELEVATION 1/4" = 1'-0" 3 A2-1 REAR ELEVATION 1/4" = 1'-0" 4 A2-1 LEFT SIDE ELEVATION 1/4" = 1'-0" EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 6" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES 3 COAT STUCCO SYSTEM 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 GENERAL NOTE: - Use modified bitumen (High Temp) underlayment along eaves, and slope transitions, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. - Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 EXTERIOR PAINT SCHEDULE EAVES/FASCIA WINDOW/DOOR TRIM STUCCO FINISH SHUTTERS PORCH (TRIM & COLUMNS) DORMERS DOOR A B C D E F G SEE COLOR SCHEME BOOK FOR PAINT COLOR SELECTIONS 2 A2-1 SIDE ELEVATION 3/16" = 1'-0" IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 EXTERIOR PAINT SCHEDULE EAVES/FASCIA WINDOW/DOOR TRIM STUCCO FINISH SHUTTERS PORCH (TRIM & COLUMNS) DORMERS DOOR A B C D E F G SEE COLOR SCHEME BOOK FOR PAINT COLOR SELECTIONS 2 A2-0 SIDE ELEVATION 3/16" = 1'-0" recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. -Use high temp modified bitumen underlayment at penetrations, typ. - Use non-corrosive fasteners and use of elastomeric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 7" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES SIMULATED STONE VENEER 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 EXTERIOR PAINT SCHEDULE EAVES/FASCIA WINDOW/DOOR TRIM STUCCO FINISH SHUTTERS PORCH (TRIM & COLUMNS) DORMERS DOOR A B C D E F G SEE COLOR SCHEME BOOK FOR PAINT COLOR SELECTIONS 2 A2-1 SIDE ELEVATION 3/16" = 1'-0" EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 7" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES SIMULATED STONE VENEER 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 EXTERIOR PAINT SCHEDULE EAVES/FASCIA WINDOW/DOOR TRIM STUCCO FINISH SHUTTERS PORCH (TRIM & COLUMNS) DORMERS DOOR A B C D E F G SEE COLOR SCHEME BOOK FOR PAINT COLOR SELECTIONS 2 A2-0 SIDE ELEVATION 3/16" = 1'-0" @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE WIN H.H @ 7'-7" WIN H.H @ 7'-7" 6'-9" WIN. H.H. 6'-9" WIN. H.H. 6'-9" WIN. H.H. 6'-9" WIN. H.H. 6'-9" WIN. H.H. 6'-9" WIN. H.H. 6'-9" WIN. H.H. 6'-9" WIN. H.H. 6'-9" WIN. H.H. 6'-9" WIN. H.H. 6'-9" WIN. H.H. 6'-9" WIN. H.H. 6:12 SLOPE 4:12 SLOPE C A B 17 15 6 B C G A A H 4 5 B 38'-51 2" B C GENERAL NOTE: - Use high temp modified bitumen underlayment along eaves, slope transitions and ridges, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. -- Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term 1 A2-1 BACK ELEVATION 3/16 = 1'-0" 2 A2-1 SIDE ELEVATION 3/16 = 1'-0" EXTERIOR PAINT SCHEDULE EAVES/FASCIA WINDOW/DOOR TRIM LAP SIDING FINISH SHUTTERS PORCH (TRIM & COLUMNS) DORMERS DOOR A B C D E F G SEE COLOR SCHEME BOOK FOR PAINT COLOR SELECTIONS H STUCCO FINISH EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 7" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES 3 COAT STUCCO SYSTEM 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" 12 6 12 4 12 4 DOOR/ WIN H.H @ 6'-9" WIN H.H @ 7'-7" PORCH BEARING @ 8'-4" 4:12 SLOPE 12 6 3'-6" TOP OF PLATE @ DORMER 3'-6" 12 6 6:12 SLOPE 4:12 SLOPE 6:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE 17 4 6 15 5 5 14 A B C G B E G B E B 38'-51 2" H C GENERAL NOTE: - Use high temp modified bitumen underlayment along eaves, slope transitions and ridges, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. -- Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term 1 A2-0 FRONT ELEVATION 3/16 = 1'-0" 2 A2-0 SIDE ELEVATION 3/16 = 1'-0" EXTERIOR PAINT SCHEDULE EAVES/FASCIA WINDOW/DOOR TRIM LAP SIDING FINISH SHUTTERS PORCH (TRIM & COLUMNS) DORMERS DOOR A B C D E F G SEE COLOR SCHEME BOOK FOR PAINT COLOR SELECTIONS H STUCCO FINISH EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 7" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES 3 COAT STUCCO SYSTEM 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 @ 2ND FLOOR TOP OF SUBFLOOR TOP OF PLATE @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE WIN H.H @ 7'-7" WIN H.H @ 7'-7" 6'-9" WIN. H.H. 6'-9" WIN. H.H. 6'-9" WIN. H.H. 6'-9" WIN. H.H. 6'-9" WIN. H.H. 6'-9" WIN. H.H. 6'-9" WIN. H.H. 6'-9" WIN. H.H. 6:12 SLOPE 4:12 SLOPE C A B B B A B A 4 5 17 6 G 15 H 38'-51 2" C C GENERAL NOTE: - Use high temp modified bitumen underlayment along eaves, slope transitions and ridges, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. -- Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term 1 A2-1 BACK ELEVATION 3/16 = 1'-0" 2 A2-1 SIDE ELEVATION 3/16 = 1'-0" EXTERIOR PAINT SCHEDULE EAVES/FASCIA WINDOW/DOOR TRIM LAP SIDING FINISH SHUTTERS PORCH (TRIM & COLUMNS) DORMERS DOOR A B C D E F G SEE COLOR SCHEME BOOK FOR PAINT COLOR SELECTIONS H STUCCO FINISH EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 7" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES 3 COAT STUCCO SYSTEM 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" 12 6 12 4 12 4 DOOR/ WIN H.H @ 6'-9" WIN H.H @ 7'-7" PORCH BEARING @ 8'-4" 12 6 3'-6" TOP OF PLATE @ DORMER 3'-6" 12 6 6:12 SLOPE 4:12 SLOPE 6:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE E B 17 4 6 15 5 5 14 38'-51 2" A B C G B E G B H C GENERAL NOTE: - Use high temp modified bitumen underlayment along eaves, slope transitions and ridges, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. -- Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term 1 A2-0 FRONT ELEVATION 3/16 = 1'-0" 2 A2-0 SIDE ELEVATION 3/16 = 1'-0" EXTERIOR PAINT SCHEDULE EAVES/FASCIA WINDOW/DOOR TRIM LAP SIDING FINISH SHUTTERS PORCH (TRIM & COLUMNS) DORMERS DOOR A B C D E F G SEE COLOR SCHEME BOOK FOR PAINT COLOR SELECTIONS H STUCCO FINISH EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 7" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES 3 COAT STUCCO SYSTEM 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" WIN. H.H @ 7'-7" WIN H.H @ 7'-7" 8'-1" WIN. H.H. 4:12 SLOPE 12 4 12 8 12 4 12 4 12 8 12 4 8:12 SLOPE 8'-1" WIN. H.H. 6'-9" DOOR. H.H. 8'-1" WIN. H.H. 6'-9" DOOR. H.H. 1 4 17 A B 17 15 6 B 4 G A B B C A C 41'-41 4" H 6 GENERAL NOTE: - Use high temp modified bitumen underlayment along eaves, slope transitions and ridges, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. -- Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term 1 A2-1 BACK ELEVATION 3/16 = 1'-0" 2 A2-1 SIDE ELEVATION 3/16 = 1'-0" EXTERIOR PAINT SCHEDULE EAVES/FASCIA WINDOW/DOOR TRIM LAP SIDING FINISH SHUTTERS PORCH (TRIM & COLUMNS) DORMERS DOOR A B C D E F G SEE COLOR SCHEME BOOK FOR PAINT COLOR SELECTIONS H STUCCO FINISH EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 7" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES 3 COAT STUCCO SYSTEM 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" 4:12 SLOPE 4:12 SLOPE 8:12 SLOPE PORCH BEARING @ 8'-4" DOOR H.H @ 6'-8" WIN H.H @ 7'-7" DOOR/ WIN H.H @ 6'-9" CJ CJ TOP OF PLATE @ DORMER 3'-6" 12 4 12 8 12 4 12 4 12 8 12 4 3'-6" 6:12 12 6 17 4 15 6 5 5 14 A B C G B E G B E B 41'-41 4" H C GENERAL NOTE: - Use high temp modified bitumen underlayment along eaves, slope transitions and ridges, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. -- Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term 1 A2-0 FRONT ELEVATION 3/16 = 1'-0" 2 A2-0 SIDE ELEVATION 3/16 = 1'-0" EXTERIOR PAINT SCHEDULE EAVES/FASCIA WINDOW/DOOR TRIM LAP SIDING FINISH SHUTTERS PORCH (TRIM & COLUMNS) DORMERS DOOR A B C D E F G SEE COLOR SCHEME BOOK FOR PAINT COLOR SELECTIONS H STUCCO FINISH EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 7" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES 3 COAT STUCCO SYSTEM 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" WIN. H.H. @ 7'-7" WIN. H.H. @ 7'-7" 6:12 SLOPE 6 12 6 12 6 12 6 12 6:12 SLOPE 4:12 DOOR/WIN. H.H. @ 6'-9" 1 4 C B 17 15 6 B G A B 1 C A A C 38'-3" GENERAL NOTE: - Use high temp modified bitumen underlayment along eaves, slope transitions and ridges, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. -- Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term 1 A2-1 BACK ELEVATION 3/16 = 1'-0" 2 A2-1 SIDE ELEVATION 3/16 = 1'-0" EXTERIOR PAINT SCHEDULE EAVES/FASCIA WINDOW/DOOR TRIM LAP SIDING FINISH SHUTTERS PORCH (TRIM & COLUMNS) DORMERS DOOR A B C D E F G SEE COLOR SCHEME BOOK FOR PAINT COLOR SELECTIONS H STUCCO FINISH EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 7" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES SIMULATED STONE VENEER 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 12 6 12 6 12 6:12 SLOPE WIN. H.H. @ 7'-7" WIN. H.H. @ 7'-7" 4:12 SLOPE DOOR/ WIN. H.H. @ 6'-9" TOP OF PLATE @ DORMER 3'-8" 6 12 6 12 6:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4 12 6 12 6 12 6 12 4:12 SLOPE 4:12 SLOPE 17 1 15 6 17 4 C A B G B E 4 C B 38'-3" GENERAL NOTE: - Use high temp modified bitumen underlayment along eaves, slope transitions and ridges, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. -- Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term 1 A2-0 FRONT ELEVATION 3/16 = 1'-0" 2 A2-0 SIDE ELEVATION 3/16 = 1'-0" EXTERIOR PAINT SCHEDULE EAVES/FASCIA WINDOW/DOOR TRIM LAP SIDING FINISH SHUTTERS PORCH (TRIM & COLUMNS) DORMERS DOOR A B C D E F G SEE COLOR SCHEME BOOK FOR PAINT COLOR SELECTIONS H STUCCO FINISH EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 7" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES SIMULATED STONE VENEER 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 @ 1ST FLOOR TOP OF SLAB @ MAIN LEVEL TOP OF SUBFLOOR TOP OF PLATE @ 3RD FLOOR 1'-2 9'-0" 3 4" 1'-2 9'-0" 3 4" 9'-0" WIN. H.H. @ 7'-7" WIN. H.H. @ 7'-7" 6:12 SLOPE DOOR/ WIN. H.H. @ 6'-9" C A 1 4 C B 17 15 6 B G A B 1 A C GENERAL NOTE: - Use high temp modified bitumen underlayment along eaves, slope transitions and ridges, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. -- Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term 1 A2-1 BACK ELEVATION 3/16 = 1'-0" 2 A2-1 SIDE ELEVATION 3/16 = 1'-0" EXTERIOR PAINT SCHEDULE EAVES/FASCIA WINDOW/DOOR TRIM LAP SIDING FINISH SHUTTERS PORCH (TRIM & COLUMNS) DORMERS DOOR A B C D E F G SEE COLOR SCHEME BOOK FOR PAINT COLOR SELECTIONS H STUCCO FINISH EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 7" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES SIMULATED STONE VENEER 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 6 12 6 12 6:12 SLOPE 6 12 6 12 6 12 WIN. H.H. @ 7'-7" WIN. H.H. @ 7'-7" 6:12 SLOPE 4:12 SLOPE DOOR/ WIN. H.H. @ 6'-9" TOP OF PLATE @ DORMER 3'-8" 6 12 6 12 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE 17 1 15 6 17 4 C A B G B E 4 C B GENERAL NOTE: - Use high temp modified bitumen underlayment along eaves, slope transitions and ridges, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. -- Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term 1 A2-0 FRONT ELEVATION 3/16 = 1'-0" 2 A2-0 SIDE ELEVATION 3/16 = 1'-0" EXTERIOR PAINT SCHEDULE EAVES/FASCIA WINDOW/DOOR TRIM LAP SIDING FINISH SHUTTERS PORCH (TRIM & COLUMNS) DORMERS DOOR A B C D E F G SEE COLOR SCHEME BOOK FOR PAINT COLOR SELECTIONS H STUCCO FINISH EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 7" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES SIMULATED STONE VENEER 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 WIN. H.H. @ 7'-7" 12 4 DOOR/ WIN. H.H. @ 6'-9" 1 4 C A B 17 15 6 B 4 17 G A B B C A C 38'-1 1/4" GENERAL NOTE: - Use high temp modified bitumen underlayment along eaves, slope transitions and ridges, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. -- Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term 1 A2-1 BACK ELEVATION 3/16 = 1'-0" 2 A2-1 SIDE ELEVATION 3/16 = 1'-0" EXTERIOR PAINT SCHEDULE EAVES/FASCIA WINDOW/DOOR TRIM LAP SIDING FINISH SHUTTERS PORCH (TRIM & COLUMNS) DORMERS DOOR A B C D E F G SEE COLOR SCHEME BOOK FOR PAINT COLOR SELECTIONS H STUCCO FINISH EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 7" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES SIMULATED STONE VENEER 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 4 12 TOP OF PLATE @ DORMER 2'-4" 6:12 SLOPE 6:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE 17 1 15 6 17 B C G B E G B E C A A 38'-1 1/4" GENERAL NOTE: - Use high temp modified bitumen underlayment along eaves, slope transitions and ridges, in 18"-24"-36" widths, in keeping with underlayment manufacturers recommendations; install underlayment along both sides of valleys at 48" upslope. If required, see detail 27 for detail of flashing at valleys. - Use membrane (high temp) flashing under metal flashing installations at windows, louvers, faux vents and wall accents. - Use non-corrosive fasteners and use of elastometric washers where applicable and for securing downspouts; typical. - Use 15# felt on all roofs. - Use neutral cure silicone sealant at all 1 2" joint openings, wall penetrations, along inside corners and cladding changes - Flash and seal wall penetrations to create a watertight cladding installation capable of performing under 6.24 psf water pressure test or equivalent rainfall - per IBC 2009; typ. -- Use double dipped galvanized roofing nails with ring shank for penetration flashing flange securement over the long term 1 A2-0 FRONT ELEVATION 3/16 = 1'-0" 2 A2-0 SIDE ELEVATION 3/16 = 1'-0" EXTERIOR PAINT SCHEDULE EAVES/FASCIA WINDOW/DOOR TRIM LAP SIDING FINISH SHUTTERS PORCH (TRIM & COLUMNS) DORMERS DOOR A B C D E F G SEE COLOR SCHEME BOOK FOR PAINT COLOR SELECTIONS H STUCCO FINISH EXTERIOR MATERIAL SCHEDULE "SMARTSIDE" HORIZONTAL LAP SIDING W/ 7" EXPOSURE 3/8" SMARTSIDE VERTICAL EXTERIOR PANEL W/ BATTEN STRIPS @ 16" O.C. SITE FENCING. SEE CIVIL FOR DETAIL. DIMENSIONAL ASPHALT SHINGLES SIMULATED STONE VENEER 5/4" "SMARTSIDE" CORNER BOARD 4" @ FRONT/REAR, 4" @ SIDES WOOD LOUVER DORMER VENT FAUX SHUTTERS. SEE DETAIL 15a to 15d ON SHEET A3.0 FOR DETAIL IF FOUR OR MORE RISERS ARE REQUIRED SEE DETAIL 72. PER IRC R311.7.7 6" VERTICAL TONGUE & GROOVE BOARDS MORTAR SMEAR SEE DETAIL 12 FOR HOUSE NUMBER LOCATION MORTAR SMEAR @ PORCH SEE DETAIL 13 FOR WINDOW CALL OUTS AND DETAILS 6" K STYLE - 4" ROUND - HIDDEN HANGER 6" - FASTENED W/ 1 1 2 " GALV. SCREW W/ NEOPRENE WASHER "SMARTSIDE" HORIZONTAL LAP SIDING W/ 4" EXPOSURE 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17