HomeMy WebLinkAboutTHE GREEN SOLUTION - PDP/FDP - FDP150045 - SUBMITTAL DOCUMENTS - ROUND 1 - STORMWATER-RELATED DOCUMENTSPROPERTY LOCATION BFE AT UPSTREAM EDGE OF BUILDING = 4967.6 FLOOR AREA DATA BFE AT UPSTREAM EDGE OF BUILDING = 4967.6 FLOOD VENTS AS REQUIRED: x OPENINGS HAVING A TOTAL NET AREA OF NOT LESS THAN ONE SQUARE INCH FOR EVERY SQUARE FOOT OF ENCLOSED AREA x OPENINGS BE ON AT LEAST 2 DIFFERENT WALLS OF THE FOUNDATION; ONE WALL BEING THE UPSTREAM WALL SEE SHEET C5.1 FOR ADDITIONAL INFORMATION. PROPOSED BUILDING FOOTPRINT EXISTING NEIGHBORING BUILDING EXISTING NEIGHBORING BUILDING PROPERTY BOUNDARY PROPERTY BOUNDARY EXISTING BUILDING FOOTPRINT EXISTING 100-YR FLOODPLAIN LIMITS SUPER-IMPOSED FROM THE FIRM FLOODPLAIN CROSS SECTIONS P.O. BOX 150894 Ŷ Lakewood, Colorado 80215 Ŷ ph: (720) 837-0648 Ŷ www.FloodplainSpecialists.com SITE DEVELOPMENT C5.0 FLOODPLAIN SITE PLAN FOR COMMERCIAL ADDITION AT 810 NORTH COLLEGE AVENUE FT. COLLINS, CO LARIMER COUNTY FLOODPLAIN SITE PLAN ORIGIN. SHEET DESCRIPTION DATE 12-09-15 C5.0 FLOODPLAIN SITE PLAN 12-09-15 C5.1 FLOODPLAIN CROSS SECTION AND FLOODPROOFING NOTES LEGEND T VERTICAL DATUM = NAVD-88 OVERALL FLOODPLAIN MAP (NTS) PROPOSED NORTH ELEVATION BFE AT UPSTREAM EDGE OF BUILDING = 4967.6 BFE AT UPSTREAM EDGE OF BUILDING = 4967.6 FREEBOARD ELEV. = 4969.6 2.0' FREEBOARD ZONE FREEBOARD ELEV. = 4969.6 FREEBOARD ELEV. = 4969.6 WATER RESISTANT MATERIALS REQUIRED WITHIN FREEBOARD ZONE, SEE NOTES THIS SHEET FOR ADDITIONAL INFOMRATION (NTS) P.O. BOX 150894 Ŷ Lakewood, Colorado 80215 Ŷ ph: (720) 837-0648 Ŷ www.FloodplainSpecialists.com SITE DEVELOPMENT C5.1 FLOODPLAIN SITE PLAN FOR COMMERCIAL ADDITION AT 810 NORTH COLLEGE AVENUE FT. COLLINS, CO LARIMER COUNTY FLOODPLAIN CROSS SECTIONS AND FLOODPROOFING NOTES ORIGIN. SHEET DESCRIPTION DATE 12-09-15 C5.0 FLOODPLAIN SITE PLAN 12-09-15 C5.1 FLOODPLAIN CROSS SECTION AND FLOODPROOFING NOTES T TABLE 2, ACCEPTABLE MATERIALS BELOW BFE (AND WITHIN THE FREEBOARD ZONE.) SEE FEMA TECHNICAL BULLETIN #2 FOR MORE INFORMATION SUBSTANTIAL AND REDEVELOPMENT IMPROVEMENTS FOR NON-RESIDENTIAL STRUCTURES: A. A SUBSTANTIAL IMPROVEMENT OCCURS WHEN ALL OF THE CONDITIONS ARE MET: a. A BUILDING PERMIT IS REQUIRED. b. THE COST OF THE IMPROVEMENT, OR THE AMOUNT OF THE DAMAGE, EQUALS OR EXCEEDS 50 PERCENT OF THE MARKET VALUE OF THE STRUCTURE EITHER BEFORE THE IMPROVEMENT OR REPAIRS IS STARTED OR BEFORE THE BUILDING WAS DAMAGED. c. THE COST IS CALCULATED CUMULATIVELY OVER THE LIFE OF THE STRUCTURE DURING THE TIME THE STRUCTURE HAS BEEN LOCATED IN A DESIGNATED FLOODPLAIN. B. IF A SUBSTANTIAL IMPROVEMENT OCCURS, THE LOWEST FLOOR OF A NON-CONFORMING STRUCTURE, INCLUDING THE BASEMENT AND ALL HVAC AND ELECTRICAL, MUST BE ELEVATED OR FLOODPROOFED 24-INCHES ABOVE THE FLOOD ELEVATION. C. A REDEVELOPMENT OCCURS WHEN THERE IS A SUBSTANTIAL IMPROVEMENT AND MORE THAN 50 PERCENT OF THE WALL PERIMETER IS REMOVED BUT THE BUILDING FOOTPRINT IS NOT INCREASED. FREEBOARD FOR NON-RESIDENTIAL STRUCTURES: A. FREEBOARD IS 24-INCHES. B. ALLOWED TO ELEVATE OR FLOODPROOF THE STRUCTURE. C. IF ELEVATING, THE LOWEST FLOOR OF THE STRUCTURE INCLUDING THE BASEMENT, ALL HVAC AND ELECTRICAL EQUIPMENT MUST BE ELEVATED ABOVE THE FREEBOARD HEIGHT. D. IF FLOODPROOFING, THE STRUCTURE AS WELL AS ALL HVAC AND ELECTRICAL, MUST BE FLOODPROOFED TO THE FREEBOARD HEIGHT. FLOODPROOFING REQUIREMENTS: A. MATERIALS BELOW THE FREEBOARD ELEVATION MUST BE CONSTRUCTED WITH MATERIALS AND UTILITY EQUIPMENT RESISTANT TO FLOOD DAMAGE (SEE TABLE 2 OF FEMA TECHNICAL BULLETIN 2, AUGUST 2008, "FLOOD DAMAGE-RESISTANT MATERIALS REQUIREMENTS .) B. HAVE AN ADEQUATE DRAINAGE SYSTEM THAT ALLOWS FLOODWATERS TO DRAIN FROM THE INTERIOR AREA OF THE CRAWLSPACE FOLLOWING A FLOOD; MORE SPECIFICALLY AS FOLLOWS: a. BE DESIGNED TO AUTOMATICALLY EQUALIZE HYDROSTATIC FLOOD FORCES ON EXTERIOR WALLS BY ALLOWING FOR THE ENTRY AND EXIT OF FLOODWATERS. (OPENINGS MAY BE EQUIPPED WITH SCREENS, LOUVERS, OR OTHER COVERINGS OR DEVICES PROVIDED THAT THEY PERMIT THE AUTOMATIC ENTRY AND EXIT OF FLOODWATERS, SEE "SMARTVENT" CATALOG FOR EXAMPLES.) b. A MINIMUM OF TWO OPENINGS HAVING A TOTAL NET AREA OF NOT LESS THAN ONE SQUARE INCH FOR EVERY SQUARE FOOT OF ENCLOSED AREA. c. OPENINGS BE ON AT LEAST 2 DIFFERENT WALLS OF THE FOUNDATION. d. HAVE AT LEAST ONE VENT ON THE UPSTREAM SIDE OF THE STRUCTURE. e. THE BOTTOM OF ALL OPENINGS SHALL BE NO HIGHER THAN ONE FOOT ABOVE EXTERIOR BACKFILL GRADE. f. THE CRAWLSPACE FLOOR BE SLOPED TO FLOW TOWARDS THE FOUNDATION WALL AND THE FLOOD OPENING.S FLOATABLE MATERIALS: A. "FLOATABLE MATERIAL" IS DEFINED AS MATERIAL THAT IS NOT SECURED IN PLACE OR COMPLETELY ENCLOSED IN A STRUCTURE SO THAT IT COULD FLOAT OFF-SITE DURING A FLOOD AND POTENTIALLY CAUSE HARM TO DOWNSTREAM PROPERTY OWNERS OR THAT COULD CAUSE BLOCKAGE OF A CULVERT, BRIDGE, OR OTHER DRAINAGE FACILITY. B. IN THE FLOOD FRINGE, FLOATABLE MATERIALS ASSOCIATED WITH ANY NON-RESIDENTIAL USE IS NOT ALLOWED. C. IN THE FLOOD FRINGE, OUTSIDE STORAGE OF MATERIAL OR EQUIPMENT THAT IS CONSIDERED "FLOATABLE MATERIAL" IS ALLOWED. CITY OF FORT COLLINS FLOODPLAIN REGULATIONS FOR THE POUDRE RIVER VERTICAL DATUM = NAVD-88