HomeMy WebLinkAboutTHE GREEN SOLUTION - PDP/FDP - FDP150045 - SUBMITTAL DOCUMENTS - ROUND 1 - ELEVATIONSFIN. FLR.
100'-0"
NEW STUCCO ON EXISTING T1-11
NEW BRICK VENEER WATERTABLE
EXISTING METAL MANSARD ROOF
ADDITION PARAPET WALL BEYOND
NEW BIKE RACKS
NEW ENTRY DOORS IN EXISTING FACADE
PAINT P1
EXISTING WOOD FRAMED
WINDOWS
REMOVE LAP SIDING
& INSTALL STUCCO
EXISTING BRICK VENEER
EXISTING METAL
MANSARD ROOF
APPROX. SIGN LOCATION
(SHOWN FOR REFERENCE
ONLY)
3/16" = 1' - 0"
3 WEST ELEVATION
A2.1
EXISTING ROOF
EXTEND EXIST. PARAPET WALL UP
NEW PARAPET
EXTERIOR MATERIALS & COLORS:
BRICK VENEER: ALL NEW BRICK TO MATCH EXISTING
WOOD LAP SIDING: ALL NEW LAP SIDING TO MATCH
EXISTING IN PROFILE & COLOR (BEIGE)
STUCCO: ALL NEW STUCCO TO MATCH EXISTING
BUILDING PRIMARY FIELD COLOR (P1-BEIGE)
TRIM & GUTTERS/D.S.: P2-PAINT GREEN (MATCH
EXISTING TRIM COLOR)
METAL ROOFING: NEW STANDING SEAM METAL ROOF
TO MATCH EXISTING COLOR & PROFILE
DOORS: HOLLOW METAL, COLOR TO MATCH EXISTING
DOORS, (P1-BEIGE)
STUCCO
EXISTING BUILDING FRONTAGE
EXISTING BRICK VENEER
EXISTING METAL ROOF
(GREEN)
EXISTING LAP SIDING,
CHANGE TO STUCCO
(BEIGE)
EXISTING TRIM (GREEN)
N.T.S.
EXISTING BUILDING FRONTAGE
FIN. FLR.
100'-0"
WALL MOUNTED LIGHT FIXTURES. NOTE: ALL SITE
LIGHTING SHALL BE FULL CUT-OFF & DOWN CAST.
STUCCO, PAINT P1
2X10 TRIM BOARD, PAINT P2
EXISTING ROOF BEYOND
ADDITION ROOF
117'-0"
EXISTING BUILDING PROPOSED ADDITION
STUCCO RTU UNIT SCREEN BEYOND
3/16" = 1' - 0"
4 SOUTH ELEVATION
A2.1
EXTEND EXISTING METAL
MANSARD ROOF BACK
NEW LAP SIDING ON
EXIST. T1-11
NEW BRICK VENEER
EXISTING METAL
MANSARD ROOF
EXTEND EXISTING PARAPET
WALL UP
EXISTING ROOF
RTU UNIT SCREEN
SCUPPER & D.S.
CONTROL
JOINTS, TYP.
CONC. SPLASHBLOCK, TYPICAL
CONC. FOUNDATION WALL
ROOF BEYOND
3/16" = 1' - 0"
2 EAST ELEVATION
A2.1
FILL EXISTING WINDOW OPENING
WITH C.M.U.
EXISTING ROOF & GUTTER
NEW BRICK VENEER ON EXISTING
CMU
EXISTING D.S.
PARGE COAT OVER EXISTING CMU
FIN. FLR.
100'-0"
EXISTING METAL MANSARD ROOF
TRASH ENCLOSURE
2X10 TRIM BOARD, PAINT P2
TRASH ENCLOUSRE
ADDITION EXISTING
FLUSH HOLLOW METAL EXIT DOOR
PAINT P1
ADDITION ROOF
117'-0"
EXISTING ROOF
FIN. FLR.
100'-0"
WALL MOUNTED LIGHT FIXTURES. NOTE: ALL SITE
LIGHTING SHALL BE FULL CUT-OFF & DOWN CAST.
BRICK VENEER PILASTER, MATCH EXISTING BRICK
STUCCO, PAINT P1
2X10 TRIM BOARD, PAINT P2 EXISTING PARGE COATED CMU
EXISTING METAL MANSARD ROOF
EXISTING WINDOW
STUCCO
EXISTING BRICK VENEER
EXISTING ROOF
ADDITION ROOF
117'-0"
WIRE MESH TRELLIS,
BLACK POWDER COAT
BRICK VENEER WATERTABLE
SLOPED SAILOR COURSE
NEW BRICK VENEER WATERTABLE ON
EXISTING PARGE COAT
PROPOSED ADDITION EXISTING BUILDING
STUCCO RTU UNIT SCREEN BEYOND
SIGN
3/16" = 1' - 0"
1 NORTH ELEVATION
A2.1
FLUSH HOLLOW METAL EXIT DOOR
PAINT P1
FLUSH HOLLOW METAL MAN DOOR
PAINT P1
STEEL ENCLOSURE
GATES, PAINT P1
TRASH ENCLOUSRE
ROOF BEYOND
THE GREEN SOLUTION
810 N. COLLEGE AVENUE
FORT COLLINS, COLORADO
SA architecture
EXTERIOR
ELEVATIONS
A2.1
PDP