Loading...
HomeMy WebLinkAboutVILLAGE ON REDWOOD (FORT COLLINS HOUSING AUTHORITY) - FDP - FDP150036 - SUBMITTAL DOCUMENTS - ROUND 2 - LANDSCAPE PLANSYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI HUNTER PROS-06-PRS30-CV WITH TORO NOZZLE 5 SERIES 30 TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. UTILIZE TORO PRECISION SERIES SPRAY NOZZLES. HUNTER PROS-06-PRS30-CV WITH TORO NOZZLE 8 SERIES 30 TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. UTILIZE TORO PRECISION SERIES SPRAY NOZZLES. HUNTER PROS-06-PRS30-CV WITH TORO NOZZLE 10 SERIES 30 TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. UTILIZE TORO PRECISION SERIES SPRAY NOZZLES. HUNTER PROS-06-PRS30-CV WITH TORO NOZZLE 12 SERIES 30 TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. UTILIZE TORO PRECISION SERIES SPRAY NOZZLES. HUNTER PROS-06-PRS30-CV WITH TORO NOZZLE 15 SERIES 30 TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. UTILIZE TORO PRECISION SERIES SPRAY NOZZLES. HUNTER PROS-06-PRS30-CV WITH TORO NOZZLE 4X STRIP SPRAY 30 TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. UTILIZE TORO PRECISION SERIES SPRAY NOZZLES. HUNTER MP1000 PROS-06-PRS40-CV 40 TURF ROTATOR, 6" (15.24 CM) POP-UP WITH CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC, O=OLIVE 360 ARC. HUNTER MP2000 PROS-06-PRS40-CV 40 TURF ROTATOR, 6" (15.24 CM) POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270, R=RED 360 ARC. HUNTER MP3000 PROS-06-PRS40-CV 40 TURF ROTATOR, 6" (15.24 CM) POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. B=BLUE ADJ ARC 90-210, Y=YELLOW ADJ ARC 210-270, A=GRAY 360 ARC. HUNTER MP3500 PROS-06-PRS40-CV 40 TURF ROTATOR, 6.0" POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY. LB=LIGHT BROWN ADJUSTABLE ARC, 90-210. HUNTER MP CORNER PROS-06-PRS40-CV 40 TURF ROTATOR, 6" (15.24CM) POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. T=TURQUOISE ADJ ARC 45-105. SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI GPM RADIUS HUNTER I-20-06-SS 45 1.50 31' TURF ROTOR, 6.0" POP-UP. ADJUSTABLE AND FULL CIRCLE. STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD NOZZLE. 2 1 A 3 3 3 3 3 1" A1 20 1" A2 16 1" A3 16 1" A4 7 1" A5 17 1" A6 14 1" A7 6 1" A8 16 1" A9 15 1" A10 18 1" A11 16 1" A12 17 1" A13 1" 17 A14 1" 5 A15 1" 20 A16 19 1" A17 6 1" A18 18 1" A19 3 3 1" A22 14 1" A23 17 1" A24 17 1" A27 7 1" A28 6 1" A29 4 1" A30 6 1" A31 10N 1" A32 5 1" A45 Drip 1" A46 Drip 1" A47 Drip 1" A50 3N 4 4 3 3 NORTH 1111 FOREST AVENUE BOULDER, COLORADO 80304 TEL 303 807 4162 leslie@eleveneleven-la.com CONSTRUCTION DOCUMENTS D C B A C SEAL: DATE: JOB NO.: DRAWN BY: 1111 FOREST AVENUE BOULDER, COLORADO 80304 TEL 303 807 4162 leslie@eleveneleven-la.com CONSTRUCTION DOCUMENTS D C B A C SEAL: DATE: JOB NO.: DRAWN BY: CHECKED BY: DRAWING TITLE: SHEET NO.: E F 1 2 3 4 5 No. Date Description 1 2 3 4 5 Fort Collins, CO Village on Redwood NOVEMBER 20, 2015 IN ASSOCATION WITH: Developer/Owner: Fort Collins Housing Authority 1715 W. Mountain Avenue Fort Collins, CO 80521 Contact : Kristin Fritz Phone : (970) 416-2910 Building Architect: OZ Architecture 3003 Larimer Street Denver, CO 80205 Contact : Jeff Swanson Phone : (303) 861-5704 Civil Engineer: Interwest Consulting Group 1218 Ash St., #C Windsor, CO 80550 Contact : Jason Claeys Phone : (970) 674-3300 3003 Larimer Street Denver, CO 80205 Contact : Jeff Swanson Pre-Construction Consultant: Deneuve Construction Services 2344 Spruce St., Suite B Boulder, CO 80302 Contact : David Garabed Phone : (303) 444-6633 Lighting Consultant: MV Consulting Inc. 5980 E. 11th Ave. Thornton, CO 80233 Contact : Marcus Vahling Phone : (303) 325-3271 1111 FOREST AVENUE BOULDER, COLORADO 80304 TEL 303 807 4162 leslie@eleveneleven-la.com CONSTRUCTION DOCUMENTS D C B A C SEAL: DATE: JOB NO.: DRAWN BY: CHECKED BY: DRAWING TITLE: SHEET NO.: E F 1 2 3 4 5 No. Date Description 1 2 3 4 5 Fort Collins, CO Village on Redwood NOVEMBER 20, 2015 IN ASSOCATION WITH: Developer/Owner: Fort Collins Housing Authority 1715 W. Mountain Avenue Fort Collins, CO 80521 Contact : Kristin Fritz Phone : (970) 416-2910 Building Architect: OZ Architecture 3003 Larimer Street Denver, CO 80205 Contact : Jeff Swanson Phone : (303) 861-5704 Civil Engineer: Interwest Consulting Group 1218 Ash St., #C Windsor, CO 80550 Contact : Jason Claeys Phone : (970) 674-3300 3003 Larimer Street Denver, CO 80205 Contact : Jeff Swanson Pre-Construction Consultant: Deneuve Construction Services 2344 Spruce St., Suite B Boulder, CO 80302 Contact : David Garabed Phone : (303) 444-6633 Lighting Consultant: MV Consulting Inc. 5980 E. 11th Ave. Thornton, CO 80233 Contact : Marcus Vahling Phone : (303) 325-3271 Irrigation Consultant: MPi Designs, LLC P. O. Box 345 Windsor, CO 80550 Contact : Michelle Peterson Phone : (970) 402-3047 MLP MLP P.O. BOX 345 Windsor, CO 80550 970.402.3047 irrigationlady@gmail.com MPi Designs, LLC IR2.2 IRRIGATION DETAILS DRIP FLUSH CAP ASSEMBLY 11 TYPICAL SLEEVE 24" min. 12 14 TYPICAL LIGHTNING ARRESTOR LAYOUT 15 LIGHTNING ARRESTOR WEATHERMATIC PEDESTAL MOUNT CONTROLLER SL-AIRCARD RJ11 CABLE (OPTIONAL) SLW5 WEATHER STATION.SYNCHRONIZE TO WEATHER STATION HUB IN CONTROLLER SL SERIES PEDESTAL MOUNT CONTROLLER DIRECT BURY WIRE TO FLOW SENSOR TO FLOW SENSOR INSTALL SLCSPLICE KIT FROM AIRCARD TO FLOW SENSOR Weathermatic CONDUIT 115V A.C. CONDUIT 24V A.C. POWER SUPPLY WIRES MASTER VALVE WIRE (OPTIONAL) VALVE CONTROL WIRES - ONE PER VALVE SL-AIRCARD. SLWMSS (191 2"WX19 1 2"HX9"D) SLPED-ENC ENCLOSURE (191/3"WX24"HX15"D) COPPER CLAD GROUND ROD (5/8" X 8') PAIGE ELECTRIC PART NUMBER 182007. MINIMUM 10' FROM PEDESTAL. NOTES: 1. INSTALL ALL WIRING PER LOCAL ELECTRICAL CODES. 2. INSTALL GROUND ROD WITHIN IRRIGATED TURF AREA. IF IRRIGATED TURF AREA IS NOT IN CLOSE PROXIMITY TO CONTROLLER, INSTALL ONE (1) DRIP EMITTER FROM NEAREST DRIP VALVE IN VALVE BOX HOUSING GROUNDING ROD. CONCRETE BASE: 6" MIN. THICKNESS, EXTEND 6" BEYOND OUTSIDE DIMENSIONS OF ENCLOSURE WITH SLOPE FOR DRAINAGE. GROUND WIRE 13 TREE RING FOR TREES IN NATIVE/TREE LAWN 10 Irrigation Consultant: MPi Designs, LLC P. O. Box 345 Windsor, CO 80550 Contact : Michelle Peterson Phone : (970) 402-3047 MLP MLP P.O. BOX 345 Windsor, CO 80550 970.402.3047 irrigationlady@gmail.com MPi Designs, LLC IR2.1 IRRIGATION DETAILS BACKFLOW PREVENTOR W/ENCLOSURE 1 QUICK COUPLING VALVE IN BOX 3 6-INCH POP-UP SPRAY 6 GEAR-DRIVEN ROTOR ASSEMBLY 7 ISOLATION GATE VALVE 4 REMOTE CONTROL TURF VALVE W/DECODER 5 1" DRIP VALVE W/BASKET FILTER & DECODER 8 MASTER VALVE/FLOW SENSOR-WEATHERMATIC 2 TYPICAL INLINE DRIP TUBING ROUTING 9 CHECKED BY: DRAWING TITLE: SHEET NO.: E F 1 2 3 4 5 No. Date Description 1 2 3 4 5 Fort Collins, CO Village on Redwood NOVEMBER 20, 2015 IN ASSOCATION WITH: Developer/Owner: Fort Collins Housing Authority 1715 W. Mountain Avenue Fort Collins, CO 80521 Contact : Kristin Fritz Phone : (970) 416-2910 Building Architect: OZ Architecture 3003 Larimer Street Denver, CO 80205 Contact : Jeff Swanson Phone : (303) 861-5704 Civil Engineer: Interwest Consulting Group 1218 Ash St., #C Windsor, CO 80550 Contact : Jason Claeys Phone : (970) 674-3300 3003 Larimer Street Denver, CO 80205 Contact : Jeff Swanson Pre-Construction Consultant: Deneuve Construction Services 2344 Spruce St., Suite B Boulder, CO 80302 Contact : David Garabed Phone : (303) 444-6633 Lighting Consultant: MV Consulting Inc. 5980 E. 11th Ave. Thornton, CO 80233 Contact : Marcus Vahling Phone : (303) 325-3271 Irrigation Consultant: MPi Designs, LLC P. O. Box 345 Windsor, CO 80550 Contact : Michelle Peterson Phone : (970) 402-3047 MLP MLP P.O. BOX 345 Windsor, CO 80550 970.402.3047 irrigationlady@gmail.com MPi Designs, LLC IR1.2 IRRIGATION PLAN 10 1" A20 14 1" A21 19 1" A25 13 1" A26 18 1" A33 15 1" A34 15 1" A35 20 1" A36 20 1" A37 8.42 1" A38 Drip 1" A39 Drip 1" A40 1" Drip A41 Drip 1" A42 Drip 1" A43 Drip 1" A44 Drip 1" A48 Drip 1" A49 Drip 1" A51 Tree NORTH 1111 FOREST AVENUE BOULDER, COLORADO 80304 TEL 303 807 4162 leslie@eleveneleven-la.com CONSTRUCTION DOCUMENTS D C B A C SEAL: DATE: JOB NO.: DRAWN BY: CHECKED BY: DRAWING TITLE: SHEET NO.: E F 1 2 3 4 5 No. Date Description 1 2 3 4 5 Fort Collins, CO Village on Redwood NOVEMBER 20, 2015 IN ASSOCATION WITH: Developer/Owner: Fort Collins Housing Authority 1715 W. Mountain Avenue Fort Collins, CO 80521 Contact : Kristin Fritz Phone : (970) 416-2910 Building Architect: OZ Architecture 3003 Larimer Street Denver, CO 80205 Contact : Jeff Swanson Phone : (303) 861-5704 Civil Engineer: Interwest Consulting Group 1218 Ash St., #C Windsor, CO 80550 Contact : Jason Claeys Phone : (970) 674-3300 3003 Larimer Street Denver, CO 80205 Contact : Jeff Swanson Pre-Construction Consultant: Deneuve Construction Services 2344 Spruce St., Suite B Boulder, CO 80302 Contact : David Garabed Phone : (303) 444-6633 Lighting Consultant: MV Consulting Inc. 5980 E. 11th Ave. Thornton, CO 80233 Contact : Marcus Vahling Phone : (303) 325-3271 Irrigation Consultant: MPi Designs, LLC P. O. Box 345 Windsor, CO 80550 Contact : Michelle Peterson Phone : (970) 402-3047 MLP MLP P.O. BOX 345 Windsor, CO 80550 970.402.3047 irrigationlady@gmail.com MPi Designs, LLC IR1.1 IRRIGATION PLAN HUNTER I-20-06-SS 45 3.00 38' TURF ROTOR, 6.0" POP-UP. ADJUSTABLE AND FULL CIRCLE. STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD NOZZLE. IRRIGATION SCHEDULE SYMBOL MANUFACTURER/MODEL/DESCRIPTION RAIN BIRD XCZ-PRB-100-COM MEDIUM PLUS FLOW DRIP CONTROL KIT FOR COMMERCIAL APPLICATIONS. FLOW RANGE 3GPM TO 20GPM. DRIPLINE FLUSH CAP AGRIFIM FLUSH CAP. 3/4" DRIPLINE COMPRESSION END CAP WITH SCREW ON END. TREE RING PER CITY DETAILS SYMBOL MANUFACTURER/MODEL/DESCRIPTION REMOTE CONTROL VALVE ASSEMBLY HUNTER MODEL ICV 1-INCH PLASTIC ELECTRIC REMOTE CONTROL VALVES, GLOBE CONFIGURATION QUICK COUPLER VALVE ASSEMBLY HUNTER HQ-5RC: VALVE WITH YELLOW RUBBER COVER, RED BRASS AND STAINLESS STEEL, WITH 1" NPT INLET, 1-PIECE BODY. ISOLATION GATE VALVE ASSEMBLY MATCO-NORCA 514TX: 1/2"-4" BRASS GATE VALVE, FULL PORT, WITH SOLID WEDGE. IPS. CROSS HANDLE. SAME SIZE AS MAINLINE PIPE. MASTER VALVE ASSEMBLY HUNTER ICV 1-INCH PLASTIC ELECTRIC MASTER VALVE, GLOBE CONFIGURATION. SIZED TO MATCH POC REDUCED PRESSURE BACKFLOW PREVENTER WILKINS 375B: BACKFLOW PREVENTER WITH BLOW OUT/FLUSH FITTING. REINFORCED NYLON HOUSING AND CAST BRONZE BALL VALVES. SIZED TO MATCH TAP & METER (RE: POC NOTE). WEATHERMATIC IRRIGATION CONTROLLER WEATHERMATIC CONTROLLER: SL1600 W/SLM48DM TWO-WIRE CONTROL SYSTEM, INCLUDES SMARTLINK AIRCARD WITH FLOW, SLW5 WEATHER STATION, AND 3-YR WARRANTY SERVICES PACKAGE (SL-AIRCARDFLOW3FW-GSM). UTILIZE STAINLESS STEEL PEDESTAL, MODEL SLPED-ENC. CREATIVE SENSOR TECHNOLOGY FSI-T 1-INCH PVC TEE TYPE FLOW SENSOR W/SOCKET ENDS, CUSTOM MOUNTING TEE AND ULTRA-LIGHTWEIGHT IMPELLER ENHANCES LOW FLOW MEASUREMENT. 2 WIRE DIGITAL OUTPUT COMPATIBLE W/ALL IRRIGATION CONTROLLERS. FLOW RANGE: .86-52 GPM. IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 PVC CLASS 200 IRRIGATION PIPE. ONLY LATERAL TRANSITION PIPE SIZES 1 1/4" AND ABOVE ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1" IN SIZE. IRRIGATION LATERAL LINE TO CITY TREE DRIP RINGS: 1-INCH IN SIZE, UV RADIATION RESISTANT POLYETHYLENE PIPE INLINE DRIP TUBING: NETAFIM TECHLINE CV WITH 0.6 GPH EMITTERS SPACED AT 18" .C., TLCV6-18. PIPE IS NOT INTENDED TO BE INSTALLED ON GRID. PIPE IS TO BE SNAKED THROUGH BED. REFER TO DETAILS. DRIP IRRIGATION LATERAL LINE TO EMITTERS IN NATIVE SEED: 3/4-INCH UV RADIATION RESISTANT POLYETHYLENE PIPE TO NETAFIM INLINE DRIP TUBING TREE RINGS (RE: DETAILS). IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 1.25-INCH UNLESS OTHERWISE NOTED (NOTE: SOME SIZES MAY BE LARGER THAN THE ABOVE) CONTROL WIRES INSTALLED WITH WARNING TAPE PER SPECIFICATIONS PIPE SLEEVE: PVC SCHEDULE 80 TYPICAL PIPE SLEEVE FOR IRRIGATION PIPE. REFER TO SPECIFICATIONS. A IRRIGATION_SCHEDULE INSTALLATION GENERAL NOTES 1. DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE FOR THE IRRIGATION SYSTEM OF 80 PSI+, AT A MINIMUM FLOW OF 20 GPM AT THE 1-INCH POINT-OF-CONNECTION (POC). VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. CONTACT GENERAL CONTRACTOR OR OWNER'S REPRESENTATIVE IMMEDIATELY IF FLOW OR PRESSURE ARE LOWER THAN LISTED ABOVE. 2. CONTRACTOR SHALL BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. FOR CLARIFICATION, CONTACT IRRIGATION DESIGNER PRIOR TO CONSTRUCTION. 3. COORDINATE UTILITY LOCATES OF UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION ("811-CALL BEFORE YOU DIG") . 4. IF DISCREPANCIES ARE NOTED IN THE FIELD BETWEEN SITE CONDITIONS AND PROVIDED DESIGNS, CONTRACTOR SHALL NOTIFY OWNER'S REPRESENTATIVE OR GENERAL CONTRACTOR IMMEDIATELY. DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM IF SUCH DISCREPANCIES IN THE FIELD AFFECT THE PROVIDED DESIGN, DETAILS, OR SPECIFICATIONS. 5. ALL IRRIGATION COMPONENTS (MAINLINE, WIRES, LATERAL LINES, ETC.) SHALL BE INSTALLED IN LANDSCAPED AREAS WHENEVER POSSIBLE, EVEN THOUGH SAID IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY. 5. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND ARCHITECTURAL FEATURES WHENEVER POSSIBLE. COORDINATE POTENTIAL RELOCATION OF BOULDERS AND TREES IN TURF AREAS WITH LANDSCAPE ARCHITECT PRIOR TO SPRINKLER LAYOUT. IF LANDSCAPE MATERIAL CANNOT BE REOLOCATED,ADDITIONAL SPRINKLERS MAY BE REQUIRED. 6. CROSS FITTINGS ARE NOT ALLOWED, ONLY STANDARD TEES AND ELBOWS. 7. CONTRACTOR SHALL INSTALL NOZZLES PER PLAN, UNLESS IRRIGATED AREA CHANGED IN SIZE OR PLANT MATERIAL TYPE CHANGES. IF NOZZLE CHANGES ARE REQUIRED AND ARE SIGNIFICANT IN SIZE, CONTRACTOR SHALL CONTACT IRRIGATION DESIGNER FOR APPROVAL. 8. CONTRACTOR SHALL FIELD LOCATE ANY EXISTING SLEEVES ON SITE PRIOR TO CONSTRUCTION WITH THE AID OF THE GENERAL CONTRACTOR. MISSING SLEEVES SHALL BE REPORTED IMMEDIATELY. NEW SLEEVES SHOWN ON PLANS ARE REQUIRED FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. 9. INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. 10. THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND. 11. TWO-WIRE CONTROL CABLE DOES NOT REQUIRE ADDITIONAL SPARE WIRES TO BE ROUTED WITH MAINLINE. 12. TREES IN TURF ARE NOT IRRIGATED BY DRIP SYSTEM. DRIP LATERAL ROUTED NEAR TREES IN TURF ARE NOT TO RECEIVE DRIP IRRIGATION. TREES IN NATIVE SEEDED AREAS ARE IRRIGATED ON DRIP SYSTEM. 13. VALVES FOR NATIVE SEEDED AREAS SHALL BE ON A SEPARATE PROGRAM. 14. NATIVE SEEDED AREAS ARE TO BE IRRIGATED WITH A BELOW GRADE SYSTEM BUT ONLY UTILIZED FOR ESTABLISHMENT ONLY. UPON ESTABLISHMENT, VALVES SHALL NOT BE UTILIZED. 15. CONTRACTOR SHALL OBTAIN AND ADHERE TO CITY OF FORT COLLINS IRRIGATION DESIGN STANDARDS. ANY DISCREPANCIES BETWEEN THE IRRIGATION PLAN AND CITY STANDARDS SHOULD BE BROUGHT TO THE DESIGN TEAM'S AND CITY'S ATTENTION PRIOR TO CONSTRUCTION. SYMBOL DESCRIPTION THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE DOWNSTREAM OF THE EXISTING IRRIGATION WATER TAP AND METER, AT THE APPROXIMATE LOCATION SHOWN. INSTALL BACKFLOW PREVENTION UNIT, MASTER VALVE ASSEMBLY, AND FLOW SENSOR AS INDICATED. VERIFY EXACT LOCATION OF POC WITH OWNER`S REPRESENTATIVE. VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. PEDESTAL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE CONTROLLER WITH THE OWNER`S REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR MAINTENANCE, AND SCREENED FROM VIEW EITHER BEHIND ENTRY WALLS, NEXT TO BUILDINGS, OR BEHIND PLANT MATERIAL. FINAL LOCATION TO BE APPROVED BY OWNER`S REPRESENTATIVE. INSTALL PER NATIONAL ELECTRIC CODE (NEC). IRRIGATION SHOWN IN HARDSCAPE FOR CLARITY ONLY. ALL IRRIGATION SHALL BE INSTALLED IN LANDSCAPED AREA. ANY IRRIGATION TO BE INSTALLED UNDER HARDSCAPE SHALL BE SLEEVED. MAINLINE, SPRINKLER LATERAL, AND/OR DRIP LATERAL SHOWN SLEEVED TOGETHER IS FOR CLARITY ONLY. CONTRACTOR SHALL INSTALL MAINLINE, CONTROL WIRES, AND LATERAL LINES IN SEPARATE SLEEVES. 1 2 3 4 REFERENCE NOTES SCHEDULE NUMBER MODEL TYPE PRECIP IN./WEEK MIN./WEEK GAL./WEEK GAL./DAY A1 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.21 in/h 1 50 1,058 151.1 A2 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.43 in/h 1 42 696.8 99.5 A3 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.21 in/h 1 50 789 112.7 A4 REMOTE CONTROL VALVE ASSEMBLY TURF ROTARY 0.46 in/h 1 130 956.9 136.7 A5 REMOTE CONTROL VALVE ASSEMBLY TURF ROTARY 0.27 in/h 1 220 3,755 536.4 A6 REMOTE CONTROL VALVE ASSEMBLY TURF ROTARY 0.32 in/h 1 187 2,526 360.9 A7 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.03 in/h 1 59 366.4 52.3 A8 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.24 in/h 1 49 793.3 113.3 A9 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.21 in/h 1 50 742.5 106.1 A10 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.43 in/h 1 42 759.4 108.5 A11 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.36 in/h 1 45 671.9 96.0 A12 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.05 in/h 1 57 1,170 167.2 A13 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.10 in/h 1 55 927.9 132.6 A14 REMOTE CONTROL VALVE ASSEMBLY TURF ROTOR 0.22 in/h 1 279 1,256 179.4 A15 REMOTE CONTROL VALVE ASSEMBLY TURF ROTOR 0.51 in/h 1 118 2,478 354 A16 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.14 in/h 1 53 984.2 140.6 A17 REMOTE CONTROL VALVE ASSEMBLY TURF ROTOR 0.18 in/h 1 337 2,022 288.9 A18 REMOTE CONTROL VALVE ASSEMBLY TURF ROTOR 0.55 in/h 1 110 1,980 282.9 A19 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 0.50 in/h 1 122 1,264 180.6 A20 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.10 in/h 1 55 761.2 108.7 A21 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 0.96 in/h 1 63 1,176 167.9 A22 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.15 in/h 1 53 734.6 104.9 A23 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.28 in/h 1 47 811.7 116.0 A24 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.11 in/h 1 55 953.2 136.2 A25 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.13 in/h 1 53 683.7 97.7 A26 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.19 in/h 1 51 913.4 130.5 A27 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.20 in/h 1 51 346.3 49.5 A28 REMOTE CONTROL VALVE ASSEMBLY TURF ROTARY 0.47 in/h 1 127 761.3 108.8 A29 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 0.81 in/h 1 75 300.8 43.0 A30 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.08 in/h 1 56 319.2 45.6 A31 REMOTE CONTROL VALVE ASSEMBLY TURF ROTARY 0.25 in/h 0.35 84 810.6 115.8 A32 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 0.93 in/h 1 65 347.8 49.7 A33 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 0.59 in/h 1 103 1,530 218.5 A34 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 0.59 in/h 1 103 1,531 218.7 A35 REMOTE CONTROL VALVE ASSEMBLY TURF ROTARY 0.51 in/h 1 119 2,365 337.9 A36 REMOTE CONTROL VALVE ASSEMBLY TURF ROTARY 0.54 in/h 1 111 2,254 322.0 A37 REMOTE CONTROL VALVE ASSEMBLY TURF SPRAY 1.27 in/h 1 48 404.2 57.7 A50 REMOTE CONTROL VALVE ASSEMBLY TURF ROTARY 0.23 in/h 0.35 91.3 250.1 35.74 TOTALS: 3,440 42,205 6,029 *RUN TIMES AND ESTIMATED WATER USAGE IS FOR REFERENCE ONLY. CONTRACTOR SHALL CREATE WATER SCHEDULE IN FIELD PER AS-BUILT CONDITIONS. WATERING SCHEDULE 1111 FOREST AVENUE BOULDER, COLORADO 80304 TEL 303 807 4162 leslie@eleveneleven-la.com CONSTRUCTION DOCUMENTS D C B A C SEAL: DATE: JOB NO.: DRAWN BY: CHECKED BY: DRAWING TITLE: SHEET NO.: E F 1 2 3 4 5 No. Date Description 1 2 3 4 5 Fort Collins, CO Village on Redwood NOVEMBER 20, 2015 IN ASSOCATION WITH: Developer/Owner: Fort Collins Housing Authority 1715 W. Mountain Avenue Fort Collins, CO 80521 Contact : Kristin Fritz Phone : (970) 416-2910 Building Architect: OZ Architecture 3003 Larimer Street Denver, CO 80205 Contact : Jeff Swanson Phone : (303) 861-5704 Civil Engineer: Interwest Consulting Group 1218 Ash St., #C Windsor, CO 80550 Contact : Jason Claeys Phone : (970) 674-3300 3003 Larimer Street Denver, CO 80205 Contact : Jeff Swanson Pre-Construction Consultant: Deneuve Construction Services 2344 Spruce St., Suite B Boulder, CO 80302 Contact : David Garabed Phone : (303) 444-6633 Lighting Consultant: MV Consulting Inc. 5980 E. 11th Ave. Thornton, CO 80233 Contact : Marcus Vahling Phone : (303) 325-3271 Irrigation Consultant: MPi Designs, LLC P. O. Box 345 Windsor, CO 80550 Contact : Michelle Peterson Phone : (970) 402-3047 MLP MLP P.O. BOX 345 Windsor, CO 80550 970.402.3047 irrigationlady@gmail.com MPi Designs, LLC IR1.0 IRRIGATION LEGEND & NOTES