HomeMy WebLinkAboutWINDSONG AT ROCK CREEK - PDP - PDP150024 - SUBMITTAL DOCUMENTS - ROUND 1 - SITE PLANPROPERTY OWNER:
HARMONY TECHNOLOGY PARK, LLC
CONTACT: MARK S. MELCHI & JEFFERY T. HARSHE
SOUTH STATE COMMONS I
2723 SOUTH STATE STREET, SUITE 250
ANN ARBOR, MI 48104
APPLICANT/ARCHITECT:
LENITY ARCHITECTURE
CONTACT: KRISTI NEZNANSKI, PROJECT MANAGER
3150 KETTLE COURT SE
SALEM, OR 97301
PHONE: (503) 399-1090
KRISTINEZ@LENITYARCHITECTURE.COM
CIVIL ENGINEER:
J.R ENGINEERING
CONTACT: TIM HALOPOFF, PE
2900 SOUTH COLLEGE AVE, SUITE 3D
FORT COLLINS, CO 44240
PHONE: (970) 491-9888
THALOPOFF@JRENGINEERING.COM
SOILS ENGINEER:
TERRACON CONSULTANTS, INC.
1901 SHARP POINT DRIVE, SUITE C
FORT COLLINS, CO 80525
PHONE: (970) 484-0359
Fort Collins, CO
VICINITY MAP
PRELIMINARY LEGAL DESCRIPTION:
A PARCEL OF LAND LOCATED IN THE SOUTHEAST
QUARTER OF SECTION 4, TOWNSHIP 6 NORTH, RANGE 68
WEST OF THE 6TH PRINCIPAL MERIDIAN, CITY OF FORT
COLLINS, COUNTY OF LARIMER, STATE OF COLORADO,
BEING IN THE SOUTHWEST CORNER OF THE PROPERTY
OF UNPLATTED RECEPTION NUMBER 20070012825
CONTRACT PUCHASER/PROJECT DEVELOPER:
VISTA POINTE DEVELOPMENT CO.,LLC
CONTACT: DON HARRIS & MIKE ZINGG
1883 SW VISTA AVENUE
PORTLAND, OR 97201
LANDSCAPE:
LENITY ARCHITECTURE
CONTACT: BRIAN LIND, LANDSCAPE ARCHITECT
3150 KETTLE COURT SE
SALEM, OR 97301
PHONE: (503) 399-1090
BRIANL@LENITYARCHITECTURE.COM
SURVEYOR:
J.R ENGINEERING
CONTACT: KEN WITTY
2900 SOUTH COLLEGE AVE, SUITE 3D
FORT COLLINS, CO 44240
PHONE: (970) 491-9888
KWITTY@JRENGINEERING.COM
TRAFFIC ENGINEER:
DELICH ASSOCIATES
CONTACT: JOSEPH DELICH
2272 GLEN HAVEN DRIVE
LOVELAND, CO 80538
PHONE: (970) 669-2061
DRAWING INDEX:
18' 24' 18'
9'
9' 9'
24' 18'
9'
18' 24' 18'
9'
68'-8"
40'-11"
40'-10"
66'-2"
24'
9'
24' 18'
90'-10"
109'-6"
ROCK CREEK DRIVE
ZIEGLER ROAD
ELEC.
MECH.
KITCHEN.
64 Bed
Memory Care Facility
1 Story
REFUSE
ENCLOSURE
ENTRANCE
ENCLOSED
YARD
ENCLOSED
YARD
BENCH
WALL
BENCH
WALL
BENCH
WALL
BENCH
WALL
BIKE
RACK
RETAINING
WALL WITH
PROJ. SIGN
RETAINING
WALL
BIKE
RACK
COLUMN
AND
TRELLIS
COLUMN
AND
TRELLIS
COLUMN
AND
TRELLIS
PERVIOUS FH
PAVERS
PERVIOUS
STAIN, OLYMPIC
SEMI-TRANSPERENT
STAIN #730 OR EQUAL.
SIDEWALK
CANTILEVER
ELEVATION SECTION
CONC. PATIO
SLAB
PRECAST
WALL CAP
FIN. LAND-
SCAPE GRADE
FIN. LAND-
SCAPE
GRADE
8" CMU WALL
W/#4 H. (2) MIN.
W/#4 V. 24"o.c.
MAX.
FTG. DEPTH
TO FROST
LINE MIN.
(PER SOILS
REPORT)
(2) #4 BARS
FULL LENGTH
FELT
STRIP
20"
24"
SCALE:
BENCH WALL
1/2" = 1'-0" P:/DON HARRIS/CO-FORT COLLINS/DETAILS/02870014PS
PRECAST
WALL CAP
STONE
STONE
1
MOUNTINGS OPTIONS:
STANDARD IN-GROUND (AS SHOWN) AND SURFACE
MOUNT WITH ROUND FLANGE
NOTES:
1. DRAWINGS NOT TO SCALE. DO NOT SCALE DRAWINGS.
CONCRETE FOOTINGS
ACCORDING TO LOCAL
SOIL CONDITIONS
GROUND LINE
HOLES ARE PRESENT
ONLY WHEN
GALVANIZED OPTION IS
SPECIFIED
FORMED FORM 2 3/8" O.D.
SCHEDULE 40 STEEL PIPE
STEEL ANCHOR ROD IS INSERTED
THROUGH THE TUBULAR POST TO
HELP SECURE THE ASSEMBLY
IN THE CONCRETE FOOTING
SCALE:
BIKE RACK
(CYCLE SENTRY SERIES BRCS-105)
NOT TO SCALE T:/02SITEWK/830FENCE/02830025
4'-0"
3'-0"
9 3/4"
1'-2 1/2"
5'-3 3/8"
5'-1 CENTER-TO-CENTER
SCALE:
TRELLIS BEAM DETAIL
1" = 1'-0" P:/DON HARRIS/CO-FORT COLLINS/DETAILS/02870012
18" SQ.
8 x 8 CEDAR POST,
SINK INTO
FOOTING 30"
1 x 12 CEDAR
TRIM
1 x 3 CEDAR
TRIM
2 x 8 SHAPED CEDAR
RAFTERS AT 12"O.C.
(2) 3 x 10 CEDAR BEAMS
(2) 3/4" DIA.
MACH. BOLTS
PREPARE SOIL UNDER
FOOTING PER SOILS
REPORT
4" CONC. SLAB w/ #4
BARS 48" o.c. e/w
1" CHAMFER EACH
CORNER
4" OF FREE-DRAINING VDCT
NO. 57 AGGREGATE OR
EQUAL
COLUMN AND TRELLIS
1/2" = 1'-0" P:/DON HARRIS/CO-FORT COLLINS/DETAILS/02870031PS
COLUMN BASE,
SIM TO
1'-107
8"
2
6
4
NOTE:
1) TREAT CMU BLOCK PRIOR TO
PAINTING W/ ELASTOMERIC PAINT.
2) VERIFY WALL HEIGHT 1-'0" GREATER
THAN TALLEST SERVICE STRUCTURE.
22'-8"
ELEVATION - SIDE ELEVATION - FRONT
ELEVATION - SIDE ELEVATION - REAR
11'-4" 5'-0" 6'-4"
8'-8" 14'-0"
16"
(2) #4 BARS
CONT. TOP &
BOTTOM 3" CLR.
FROM EDGES
F.G.
#4 BARS AT 32"
O.C. BOTH WAYS
& CENTER
REINFORCING IN
WALL PROVIDE
MINIMUM 18"
EMBEDMENT
12"x4"x16"
SLOPED CMU
CAP
6" THK. P.C.C.
SLAB W/
6"x6"-10/10
WWM ON 6"
AGG. BASE
CONCRETE FOOTONG MINIMUM
COMPRESSION CONC. STRENGTH
AT 28 DAYS SHALL BE 3,000 PSI.
JAMB DETAIL
1/2"ɸx8" BARREL
BOLT LOCK
(ONE GATE)
3/8"ɸ BAR 8"x2"
WELDED TO STEEL
TUBE AT 16" O.C.
8"x8"x16"
CMU WALL
3"x4"x1/4" METAL ANGLE FRAME
(4) SIDES EA. GATE W/ (2) PAIR
MCKINNEY T4B3781LE HINGES
EACH GATE
1/2"ɸx30"
CANE BOLT
ONE GATE
1 1/2"x1 1/2"x3/16"
METAL ANGLE
DIAGONAL BRACE
5"x5"x1/4" STEEL
TUBE W/ 5"x5"x1/4"
CAP PLATE
EMBEDDED 3'-0"
INTO FOOTING
1"x18 GA.
METAL GATE
SCALE:
ENCLOSURE
TRASH & RECYCLING
1/8" = 1'-0" P:/DON HARRIS/CO-FORT COLLINS/DETAILS/ENCLOSURE-TRASH
BOLLARD
(TYP OF 4)
TRANSFORMER
PAD, SIZE PER
ELEC.
GENERATOR
PAD, SIZE PER
ELEC. TRASH
CONTAINER
OPEN
4 X 2 T.S. GATE FRAME
STONE CAP W/ 1"
OVERHANG
8" CMU - PAINT
INSIDE
4 X 2 T.S. DIAGONAL BRACE
5"x5"x1/4" STEEL TUBE W/
5"x5"x1/4" CAP PLATE EMBEDDED
3'-0" INTO FOOTING
1/2"ɸx30" CANE BOLT ONE GATE
PROVIDE STL. PIPE RECEIVER
IN CONCRETE PAD
1/2"ɸx8" BARREL BOLT
LOCK (ONE GATE)
USER ENTRY
FOOTING
DETAIL
GRAVEL
6" THICK PCC SLAB
W/ 6"x6"-10/10 WWM
ON 6" GRAVEL BASE.
1/4" PER FT.
A
--
B
--
CONC.
CURB
C.M.U. PAINTED TO MATCH
STONE VENEER
C.M.U. PAINTED TO
MATCH STONE
VENEER
C.M.U. PAINTED TO MATCH
STONE VENEER
BOLLARD
SLOPE
RECYCLING
CONTAINERS
3
+2'-0"
ELEV.
MASTIC WATERPROOFING AND
PROTECTION BOARD
UNDISTURBED OR
COMPACTED
GRADE
4" PERF. DRAINPIPE IN 8"x8"
GRAVEL RUN ENCASED IN
FILTER FABRIC
CONTINUOUS, CONNECT
TO STORM SEWER
AMENDED PLANTING SOIL
BACKFILL
10" CMU GROUT SOLID
#3 TIES AT 24" o.c.
SIDEWALK PER PALN
18"±
MIN.
(2) #4 CONT. BAR IN
FOOTING
CONT. CONC.
FOOTING
21
2"
1"
STONE VENEER,
COLOR TO MATCH
MAIN BUILDING, SET
IN MORTAR BED
OVER APPROVED
METAL LATH AND
WEATHER BARRIER,
PER MANUF. SPECS.
1/2" GAP BETWEEN
CONC. AND STONE
SCALE:
SECTION
(RAISED PLANTER)
1-1/2" = 1'-0" P:/DON HARRIS/CO-FORT COLLINS/DETAILS/02870055
CAST IN PLACE CAP
MASTIC WATERPROOFING AND
PROTECTION BOARD
UNDISTURBED OR
COMPACTED
GRADE
4" PERF. DRAINPIPE IN 8"x8" GRAVEL
RUN ENCASED IN FILTER FABRIC
CONTINUOUS, CONNECT TO STORM
SEWER
AMENDED PLANTING SOIL
BACKFILL
GRADE LINE
WITH GRASS
(2) #4 CONT. BAR IN
FOOTING
CONT. CONC.
FOOTING
STONE VENEER,
COLOR TO MATCH
MAIN BUILDING,
SET IN MORTAR
BED OVER
APPROVED METAL
LATH AND
WEATHER
BARRIER, PER
MANUF. SPECS.
SCALE:
SECTION
(RAISED PLANTER)
1 1/2" = 1'-0" P:/DON HARRIS/CO-FORT COLLINS/DETAILS/02870056
+2'-0"
ELEV.
1"
21
2"
18"±
MIN.
10" CMU GROUT
SOLID
#3 TIES AT 24" o.c.
CAST IN PLACE CAP
8 5
75 1/4"
OUT TO OUT
18"
31 5/8"
1 1/4" SCH 40 STEEL PIPE
NOTE: ALL
CONNECTIONS
TO SITE PER
MANUF.
INSTALLATION
INSTRUCTIONS
SCALE:
FAIRWEATHER SITE FURNITURE (MODEL AL-2 OR SIMILAR)
1" = 1'-0" P:/DON HARRIS/CO-FORT COLLINS/DETAILS/LANDSCAPE_BENCH
6' BENCH (SHOWN) - 71 1/2"
POWDER-COATED IN A BLACK
FINISH TO MATCH CITY
STANDARD
7
Fort Collins, CO
SCALE: AS NOTED
DATE: 18 Nov. 2015
PAVERS
PERVIOUS
PAVERS
BENCH
RAISED
PLANTER
RAISED
PLANTER
EMPLOYEE
AREA
GENERATOR
TRANSFORMER
422.83'
VACANT LAND
VACANT LAND
395.47'
EMERGENCY
ACCESS EASEMENT
EMERGENCY
ACCESS EASEMENT
EMERGENCY
ACCESS EASEMENT
351.25'
342.20'
PERVIOUS
PAVERS
LOADING
GREASE
INTERCEPTOR
Fort Collins, CO
SCALE: 1" = 30'-0"
0 15 30 60 90
DATE: 18 Nov. 2015
GENERAL NOTES:
1. REFER TO THE CIVIL ENGINEERS UTILITY PLAN SET
FOR DETAILED INFORMATION REGARDING EXISTING
CONDITIONS AND CONTOURS.
2. REFER TO THE CIVIL ENGINEERS SUBDIVISION PLAT
DRAWING SET FOR DETAILED INFORMATION ON
PUBLIC, PRIVATE AND EMERGENCY SERVICE
EASEMENTS AND PUBLIC RIGHTS OF WAY.
PROJECT DESCRIPTION:
64 BED MEMORY CARE FACILITY
24 PRIVATE BEDS
40 SEMI-PRIVATE BEDS
64 BEDS TOTAL
BUILDING HEIGHT: ONE STORY
GRADE TO MEAN: 15'-2"
GRADE TO RIDGE:20'-6"
ZONING: HARMONY CORRIDOR DISTRICT (HC)
EXISTING LAND USE: VACANT, AGRICULTURAL
PROPOSED LAND USE: LONG-TERM CARE FACILITY
PROJECT AREA CALCULATIONS:
TOTAL AREA: 3.337 ACRES 145,364 SF 100%
BUILDING AREA: 38,303 SF 26.3%
DRIVES: 34,860 SF 24.0%
WALKS & PATIOS: 17,627 SF 12.1%
LANDSCAPED OPENSPACE: 54,574 SF 37.6%
FLOOR AREA RATIO: 0.26%
OFF STREET PARKING:
VEHICLE:
47 OPEN SPACES
4 ACCESSIBLE SPACES
51 TOTAL SPACES
BICYCLE:
2 OUTDOOR FIXED RACKS
10 TOTAL SPACES
COVER
SITE PLAN
SITE DETAILS
LANDSCAPE PLAN
LANDSCAPE LEGEND & NOTES
LANDSCAPE HYDROZONE PLAN
LIGHTING PLAN
LIGHTING PHOTOMETRIC PLAN
COLOR SITE PLAN
FLOOR PLAN
EXTERIOR ELEVATIONS
COLOR & MATERIALS
WALL/BERM DETAIL
PROJECT DESCRIPTION:
64 BED MEMORY CARE FACILITY
24 PRIVATE BEDS
40 SEMI-PRIVATE BEDS
64 BEDS TOTAL
BUILDING HEIGHT: ONE STORY
GRADE TO MEAN: 15'-2"
GRADE TO RIDGE:20'-6"
ZONING: HARMONY CORRIDOR DISTRICT (HC)
EXISTING LAND USE: VACANT, AGRICULTURAL
PROPOSED LAND USE: LONG-TERM CARE FACILITY
PROJECT AREA CALCULATIONS:
TOTAL AREA: 3.337 ACRES 145,364 SF 100%
BUILDING AREA: 38,303 SF 26.3%
DRIVES: 34,860 SF 24.0%
WALKS & PATIOS: 17,627 SF 12.1%
LANDSCAPED OPENSPACE: 54,574 SF 37.6%
FLOOR AREA RATIO: 0.26%
OFF STREET PARKING:
VEHICLE:
47 OPEN SPACES
4 ACCESSIBLE SPACES
51 TOTAL SPACES
BICYCLE:
2 OUTDOOR FIXED RACKS
10 TOTAL SPACES
OWNERS CERTIFICATION:
THE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT
I/WE ARE LAWFUL OWNERS OF REAL PROPERTY
DESCRIBED ON THIS SITE PLAN AND DO HEREBY
CERTIFY THAT I/WE ACCEPT THE CONDITIONS AND
RESTRICTIONS SET FORTH ON SAID SITE PLAN.
___________________________________ _____________
SIGNATURE DATE
___________________________________
(PRINT NAME)
THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED
BEFORE ME
THIS _____ DAY OF__________, 20____
___________________________________
(PRINT NAME)
MY COMMMISSION EXPIRES: ________________________
WITNESS MY HAND AND OFFICIAL SEAL
___________________________________
NOTARY PUBLIC
PLANNING AND ZONING CERTIFICATION:
APPROVED BY THE PLANNING AND ZONING BOARD OF
THE CITY OF FORT COLLINS, COLORADO
THIS _____ DAY OF__________, 20____
_________________________________________________
COMMUNITY DEVELOPMENT AND NEIGHBORHOOD