Loading...
HomeMy WebLinkAboutUNCOMMON (310 S. COLLEGE) - FDP - FDP150038 - SUBMITTAL DOCUMENTS - ROUND 1 - LANDSCAPE PLAN (3)S TF FDC DN UP SOUTH COLLEGE AVENUE OLIVE STREET EXISTING TREES LIMITS OF STRUCTURAL SOIL CU-STRUCTURAL SOIL REF SPEC SCHEMATIC IRRIGATION LINE LOCATION SCHEMATIC AERATION MAINLINE LOCATION AIR INTAKE CAP LOCATION IS SCHEMATIC Schematic Aeration Exhibit Fort Collins, Colorado UNCOMMON Final Development Plan GROUP landscape architecture|planning|illustration 444 Mountain Ave. Behtroud,CO 80513 TEL WEB 970.532.5891 TBGroup.us PROJECT TITLE REVISIONS ISSUE DATE SHEET TITLE SHEET INFORMATION DATE SEAL JULY 15, 2015 DATE PREPARED FOR SHEET OF Staff Comments 9.2.15 Staff Comments 11.18.15 SCALE 1" = 20'-0" 0 20' 30' 40' NORTH AERATION SYSTEM SHOULD TERMINATE AT SIX + INCHES OF FILL. LENGTH OF LINE SHOWN IS SCHEMATIC AND DOES NOT REPRESENT FILL CONDITIONS. TERMINATION POINT TO BE DETERMINED IN THE FIELD. 1. AERATION MAINLINE LENGTHS AND SIZE ARE SCHEMATIC AND DO NOT REPRESENT TRUE MEASUREMENTS. AERATION MAINLINE TO BE INSTALLED APPROXIMATELY 18" FROM THE WEST SIDE OF THE SIDEWALK. 2. IRRIGATION LINE LOCATION AND SIZE IS SCHEMATIC. TO BE PLACED BETWEEN WALK AND AERATION MAINLINE. 3. IRRIGATION LINE ALONG COLLEGE AVENUE AND A PORTION OF OLIVE STREET TO BE ADJUSTED BY DEVELOPER AND MAINTAINED BY THE CITY OF FORT COLLINS. LINE TO BE CONNECTED MUNICIPAL WATER SUPPLY. AN INSPECTION WILL BE REQUIRED BY CITY OF FORT COLLINS PARKS, FORESTRY AND ENGINEERING BEFORE ACCEPTANCE OF THE IRRIGATION LINE. IRRIGATION LINE ALONG OLIVE STREET (PORTION CURRENTLY WITHOUT IRRIGATION SYSTEM) TO BE INSTALLED AND MAINTAINED BY DEVELOPER. NEW OLIVE STREET IRRIGATION LINE TO BE CONNECTED TO PROPERTY WATER SUPPLY. 4. AIR INTAKE CAPS TO BE INSTALLED FLUSH WITH GRADE. 5. AIR INTAKE CAPS TO BE SPACED APPROXIMATELY AT EACH TREE TRUNK. 6. MAINLINE TO BE INSTALLED FLUSH WITH EXISTING WALK ELEVATION. 7. TREE LAWN SURROUNDING LINDEN TREES, WITH SIX OR MORE INCHES OF FILL REQUIRE THE INSTALLATION OF AN AERATION SYSTEM. AREAS WITH LESS THAN SIX INCHES OF FILL DO NOT REQUIRE AN AERATION SYSTEM. 8. TREE LAWN SURROUNDING THE AMERICAN ELM, WITH THREE OR MORE INCHES OF FILL REQUIRE THE INSTALLATION OF AN AERATION SYSTEM. AREAS WILL LESS THAN THREE INCHES OF FILL DO NOT REQUIRE AN AERATION SYSTEM. 9. REFER TO ATTACHED SYSTEM PRODUCT INFORMATION. 10. INSTALLATION OF AERATION SYSTEM, IRRIGATION SYSTEM, STRUCTURAL SOIL AND CONCRETE WALK TO BE COORDINATED WITH CONTRACTOR. 11. STRUCTURAL SOIL SHALL NOT BE LOCATED UNDER WALKS IF OVER EXCAVATION IS REQUIRED IN ORDER TO ACHIEVE THE REQUIRED DEPTH TO PACE IT. 12. PROTECT EXISTING IRRIGATION LINES TO REMAIN. EXISTING IRRIGATION LINES MAY NEED TO SHIFT TO BE LOCATED ADJACENT TO NEW SIDEWALKS. 13. SEQUENCE INSTALLATION OF RIGHT-OF-WAY IMPROVEMENTS TO PROTECT INSTALLED IMPROVEMENTS FROM CONSTRUCTION. NO HEAVY EQUIPMENT/TRAFFIC WILL BE PERMITTED IN THE ROW ONCE SOIL, AERATION AND IRRIGATION IMPROVEMENTS HAVE BEEN INSTALLED. Landscape Legend Aeration Notes: AIR INTAKE CAP MAINLINE - 3" ADS PERFORATED PIPE OR APPROVED EQUAL WITH FILTER FABRIC PROPOSED MITIGATION TREE PROPOSED MITIGATION TREE PROPOSED MITIGATION TREE 1 1