HomeMy WebLinkAboutUNCOMMON (310 S. COLLEGE) - FDP - FDP150038 - SUBMITTAL DOCUMENTS - ROUND 1 - LANDSCAPE PLAN (3)S
TF
FDC
DN
UP
SOUTH COLLEGE AVENUE
OLIVE STREET
EXISTING TREES LIMITS OF STRUCTURAL SOIL
CU-STRUCTURAL SOIL REF SPEC
SCHEMATIC IRRIGATION LINE LOCATION
SCHEMATIC AERATION MAINLINE LOCATION
AIR INTAKE CAP
LOCATION IS SCHEMATIC
Schematic
Aeration Exhibit
Fort Collins, Colorado
UNCOMMON
Final
Development Plan
GROUP
landscape architecture|planning|illustration
444 Mountain Ave.
Behtroud,CO 80513
TEL
WEB
970.532.5891
TBGroup.us
PROJECT TITLE
REVISIONS
ISSUE DATE
SHEET TITLE
SHEET INFORMATION
DATE
SEAL
JULY 15, 2015
DATE
PREPARED FOR
SHEET OF
Staff Comments 9.2.15
Staff Comments 11.18.15
SCALE 1" = 20'-0"
0 20' 30' 40'
NORTH
AERATION SYSTEM SHOULD
TERMINATE AT SIX + INCHES OF FILL.
LENGTH OF LINE SHOWN IS SCHEMATIC
AND DOES NOT REPRESENT FILL
CONDITIONS. TERMINATION POINT TO BE
DETERMINED IN THE FIELD.
1. AERATION MAINLINE LENGTHS AND SIZE ARE SCHEMATIC AND DO NOT REPRESENT TRUE MEASUREMENTS. AERATION MAINLINE TO BE
INSTALLED APPROXIMATELY 18" FROM THE WEST SIDE OF THE SIDEWALK.
2. IRRIGATION LINE LOCATION AND SIZE IS SCHEMATIC. TO BE PLACED BETWEEN WALK AND AERATION MAINLINE.
3. IRRIGATION LINE ALONG COLLEGE AVENUE AND A PORTION OF OLIVE STREET TO BE ADJUSTED BY DEVELOPER AND MAINTAINED BY THE CITY
OF FORT COLLINS. LINE TO BE CONNECTED MUNICIPAL WATER SUPPLY. AN INSPECTION WILL BE REQUIRED BY CITY OF FORT COLLINS PARKS,
FORESTRY AND ENGINEERING BEFORE ACCEPTANCE OF THE IRRIGATION LINE. IRRIGATION LINE ALONG OLIVE STREET (PORTION CURRENTLY
WITHOUT IRRIGATION SYSTEM) TO BE INSTALLED AND MAINTAINED BY DEVELOPER. NEW OLIVE STREET IRRIGATION LINE TO BE CONNECTED TO
PROPERTY WATER SUPPLY.
4. AIR INTAKE CAPS TO BE INSTALLED FLUSH WITH GRADE.
5. AIR INTAKE CAPS TO BE SPACED APPROXIMATELY AT EACH TREE TRUNK.
6. MAINLINE TO BE INSTALLED FLUSH WITH EXISTING WALK ELEVATION.
7. TREE LAWN SURROUNDING LINDEN TREES, WITH SIX OR MORE INCHES OF FILL REQUIRE THE INSTALLATION OF AN AERATION SYSTEM.
AREAS WITH LESS THAN SIX INCHES OF FILL DO NOT REQUIRE AN AERATION SYSTEM.
8. TREE LAWN SURROUNDING THE AMERICAN ELM, WITH THREE OR MORE INCHES OF FILL REQUIRE THE INSTALLATION OF AN AERATION
SYSTEM. AREAS WILL LESS THAN THREE INCHES OF FILL DO NOT REQUIRE AN AERATION SYSTEM.
9. REFER TO ATTACHED SYSTEM PRODUCT INFORMATION.
10. INSTALLATION OF AERATION SYSTEM, IRRIGATION SYSTEM, STRUCTURAL SOIL AND CONCRETE WALK TO BE COORDINATED WITH
CONTRACTOR.
11. STRUCTURAL SOIL SHALL NOT BE LOCATED UNDER WALKS IF OVER EXCAVATION IS REQUIRED IN ORDER TO ACHIEVE THE REQUIRED DEPTH
TO PACE IT.
12. PROTECT EXISTING IRRIGATION LINES TO REMAIN. EXISTING IRRIGATION LINES MAY NEED TO SHIFT TO BE LOCATED ADJACENT TO NEW
SIDEWALKS.
13. SEQUENCE INSTALLATION OF RIGHT-OF-WAY IMPROVEMENTS TO PROTECT INSTALLED IMPROVEMENTS FROM CONSTRUCTION. NO HEAVY
EQUIPMENT/TRAFFIC WILL BE PERMITTED IN THE ROW ONCE SOIL, AERATION AND IRRIGATION IMPROVEMENTS HAVE BEEN INSTALLED.
Landscape Legend
Aeration Notes:
AIR INTAKE CAP
MAINLINE - 3" ADS PERFORATED PIPE
OR APPROVED EQUAL WITH FILTER
FABRIC
PROPOSED MITIGATION TREE
PROPOSED MITIGATION TREE
PROPOSED MITIGATION TREE
1 1