Loading...
HomeMy WebLinkAboutVILLAGE ON REDWOOD (FORT COLLINS HOUSING AUTHORITY) - FDP - FDP150036 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORTFINAL DRAINAGE REPORT FOR Village on Redwood Prepared by: Interwest Consulting Group 1218 West Ash, Suite A Windsor, Colorado 80550 Phone: 970.674.3300 Fax: 970.674.3303 Prepared for: Fort Collins Housing Authority 1715 West Mountain Ave. Fort Collins, Colorado 80521 Phone: 970.416.2910 October 14, 2015 Job Number 1237-112-00 October 14, 2015 Mr. Wes Lamarque Fort Collins Utilities 700 Wood Street Fort Collins, CO 80522 RE: Final Drainage Report for Village on Redwood Dear Wes, We are pleased to submit for your review and approval, this Final Drainage Report for the Village on Redwood low-income housing development. I certify that this report for the drainage design was prepared in accordance with the criteria in the City of Fort Collins Storm Drainage Manual. I appreciate your time and consideration in reviewing this submittal. Please call if you have any questions. Sincerely, Jason T. Claeys, P.E., LEED AP Interwest Consulting Group 1218 W. ASH, STE. A, WINDSOR, COLORADO 80550 TEL. 970.674.3300 – FAX 970.674.3303 TABLE OF CONTENTS 1. INTRODUCTION ................................................................................................................................................. 1 2. EXISTING CONDITIONS .................................................................................................................................... 1 3. DEVELOPED CONDITIONS ............................................................................................................................... 2 4. LOW IMPACT DEVELOPMENT TECHNIQUES .............................................................................................. 3 5. CONCLUSION ...................................................................................................................................................... 3 6. REFERENCES ...................................................................................................................................................... 4 APPENDIX A — SITE DESCRIPTIONS, CHARACTERISTICS & REFERENCES ........................................ A APPENDIX B — RATIONAL CALCULATIONS .................................................................................................. B APPENDIX C — STORM DRAIN SIZING ............................................................................................................ C APPENDIX D — DETENTION POND CALCULATIONS ................................................................................... D APPENDIX E — LOW IMPACT DEVELOPMENT CALCULATIONS ............................................................ E 1 1. INTRODUCTION The project site currently is an undeveloped infill site located north of Nokomis Ct and west of Redwood St. The site is 9.61 acres with approximately 3.0± acres being an existing detention pond and approximately 6.6± acres of developable land. The property will be subdivided into two lots, one containing the existing detention pond and the other being the developed portion for low income housing. The project will consist of constructing 12 low income housing buildings, a community clubhouse, and associated pedestrian and vehicle accesses. This project will be completed in one phase of construction. 2. EXISTING CONDITIONS The project site is bound by Redwood St to the east and surrounded by previously developed properties on the north, south, and west. The site is currently undeveloped and appears to be vegetated with native grasses and wetland plants surrounding the existing detention pond. The existing detention pond encompasses the western portion of the site. Based on research of the site, it appears that this detention pond was constructed sometime after 1975. The site is within the Dry Creek basin and within the basin limits of the Northeast College Corridor Outfall improvements. The existing site is approximately 2.7% impervious, including the west half of Redwood St. The existing 100-yr peak runoff rate from Redwood St (Basin H1) and to the existing detention pond (Basin H2) is 14.10 cfs and 11.31 cfs, respectively. The runoff directed to Redwood St is conveyed to and collected by an existing 15’ Type R inlet located near the southeast corner of the site. Upon further research of the surrounding storm drainage infrastructure, the design drawings and calculations were found. Referencing the “Redwood Street Improvements” plan set, dated September 1996 and prepared by Stewart & Associates, the existing storm drain within Redwood Street was sized and constructed to convey the 100-yr developed runoff from the proposed Village on Redwood site. The storm drain is anticipated to capture and convey 33.5 cfs from the site during a 100-yr storm event. The recorded documents are attached for reference and further discussion is needed to determine the impacts to the proposed storm drain system within Villages on Redwood. The existing runoff rates, stated above, are referenced for the stormwater release rates for 2 the proposed improvements. All calculations and exhibits are attached. 3. DEVELOPED CONDITIONS The project proposes to develop this infill site with 12 low income housing buildings (with a total of 72 units), a community clubhouse and associated infrastructure and site/building pedestrian and vehicle access. The property will be subdivided into 2 lots, one containing the existing detention pond and the remaining containing the proposed low income housing development. The project is required to detain the developed 100-yr runoff to the existing 100-yr runoff rate. Further discussion is needed due to the recent information found determining that the existing storm drain within Redwood Street was sized and constructed to convey 33.5 cfs from the Village on Redwood site. The detention requirements will be provided through the use of a detention pond in the southeast corner of the site. Water quality capture volume and associated infrastructure is not required as part of this project, though implementation of Low Impact Development (LID) techniques for water quality enhancement are required and proposed with this project. Similar to the existing conditions, the proposed project is divided into two major basins, one basin draining undetained to the existing detention pond to the west (Basin D7), and the remaining basin draining towards Redwood St (Basins D1 thru D6). In general, the basin limits are maintained for the areas draining to the existing detention pond and towards Redwood Street. This causes a slight increase to the existing pond and is considered negligible. Runoff from Basins D1 thru D5 are conveyed to the proposed detention pond in the southeast corner of the site, with the outfall being the connection to the existing storm drain within Redwood St. The undetained developed portion (Basin D6) drains to the existing inlet within Redwood St. Under the developed condition, the 100-yr peak runoff rates to the existing detention pond and Redwood Street are estimated to be 12.33 cfs and 34.25 cfs, respectively. Detaining the developed runoff to the existing 100-yr runoff rate for the basin draining towards Redwood Street, in addition to accounting for the undetained portions that drain directly to Redwood, requires a detention volume of 0.375 acre-ft. The undetained portion has a runoff rate of 7.20 cfs, combined with detention pond release rate of 6.90 cfs, has a peak 100-yr runoff rate of 14.10 cfs, equal to the existing 100-yr runoff rate. 3 The storm drain pipe sizes were determined utilizing Hydraflow. The storm drain system has been designed to convey the 100-yr storm through a combination of the pipe and overland flow. The grading design is such that when the hydraulic grade line exceeds the pipe capacities at the inlets, the runoff will overtop the adjacent high point and convey overland ultimately to the proposed detention pond. All preliminary calculations and exhibits are attached for reference. 4. LOW IMPACT DEVELOPMENT TECHNIQUES In reference to the code requirements for implementation of Low Impact Development (LID) techniques, the use of permeable pavers and a sand filter are necessary to satisfy these requirements. The main LID being proposed to be implemented on site are permeable pavers located in sections of the north and south drives. The remaining developed area will be treated by a sand filter located near the southeast corner of the site within the detention pond. The sand filter is designed to detain and infiltrate the required water quality capture volume and directly spill into the detention area for events beyond the capacity of the sand filter. The sand filter water quality capture volume is designed to have a depth of 12 inches. Underdrains are not required with a full infiltration design. Percolation test was performed and is provided in the appendix. Based on the average percolation rate of 8.6 minutes per inch, it is estimated that the water quality capture volume will infiltrate within 2 hrs of filling. A Standard Operations Procedure will be provided to assist in ensuring that these BMPs will adequately perform over time. All calculations are attached for reference. 5. CONCLUSION All computations that have been completed within this report are in compliance with the CoFC Stormwater Criteria Manual, and Urban Drainage and Flood Control District requirements and standards. The proposed drainage concepts presented in this report and on the construction plans adequately provide for stormwater quantity and quality treatment of proposed impervious areas. Conveyance elements have been designed to pass required flows and to minimize future maintenance. If, at the time of construction, groundwater is encountered, a Colorado Department of Health Construction Dewatering Permit will be required. 4 6. REFERENCES 1. Urban Storm Drainage Criteria Manual (Volumes 1, 2, and 3), Urban Drainage and Flood Control District, June 2001, Revised April 2008. 2. Storm Drainage Criteria Manual and Construction Standards, City of Fort Collins Storm Water Utility, City of Fort Collins, Colorado, Updated January, 1997 with 2012 amendments. 3. “Hydrologic Group Rating for Larimer County Area, Colorado”, USDA-Natural Resources Conservation Service, National Cooperative Soil Survey. Web Soil Survey URL: http://websoilsurvey.nrcs.usda.gov. [03/28/2014] APPENDIX A — SITE DESCRIPTIONS, CHARACTERISTICS & REFERENCES vicinity map PROJECT DATUM: NAVD88 CITY OF FORT COLLINS BENCHMARK #42-97 ON TOP OF A STORM INLET STRUCTURE ON THE EAST SIDE OF REDWOOD ST., 400 FEET SOUTH OF WILLOX LANE. ELEV= 4969.93 CITY OF FORT COLLINS BENCHMARK #43-97 ON THE SOUTH END OF THE WEST HEADWALL OF THE LAKE CANAL BRIDGE AT NORTH LEMAY AVE., 200 FEET SOUTH OF THE INTERSECTION OF LEMAY AVE. AND CONIFER ST. ELEV= 4960.11 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATIONS SHOULD BE USED: NGVD29 UNADJUSTED = 4969.93 (NAVD88) - 3.18 = 4966.75 NGVD29 UNADJUSTED = 4960.11 (NAVD88) - 3.17 = 4956.94 Hydrologic Soil Group—Larimer County Area, Colorado Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 10/14/2015 Page 1 of 4 4494910 4494940 4494970 4495000 4495030 4495060 4495090 4494910 4494940 4494970 4495000 4495030 4495060 4495090 494040 494070 494100 494130 494160 494190 494220 494250 494280 494310 494340 494040 494070 494100 494130 494160 494190 494220 494250 494280 494310 494340 40° 36' 24'' N 105° 4' 14'' W 40° 36' 24'' N 105° 4' 0'' W 40° 36' 17'' N 105° 4' 14'' W 40° 36' 17'' N 105° 4' 0'' W N Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS84 0 50 100 200 300 Feet 0 20 40 80 120 Meters Map Scale: 1:1,470 if printed on A landscape (11" x 8.5") sheet. MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Rating Polygons A A/D B B/D C C/D D Not rated or not available Soil Rating Lines A A/D B B/D C C/D D Not rated or not available Soil Rating Points A A/D B B/D C C/D D Not rated or not available Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: http://websoilsurvey.nrcs.usda.gov Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Larimer County Area, Colorado Hydrologic Soil Group Hydrologic Soil Group— Summary by Map Unit — Larimer County Area, Colorado (CO644) Map unit symbol Map unit name Rating Acres in AOI Percent of AOI 64 Loveland clay loam, 0 to 1 percent slopes C 3.3 32.5% 73 Nunn clay loam, 0 to 1 percent slopes C 7.0 67.5% Totals for Area of Interest 10.3 100.0% Description Hydrologic soil groups are based on estimates of runoff potential. Soils are assigned to one of four groups according to the rate of water infiltration when the soils are not protected by vegetation, are thoroughly wet, and receive precipitation from long-duration storms. The soils in the United States are assigned to four groups (A, B, C, and D) and three dual classes (A/D, B/D, and C/D). The groups are defined as follows: Group A. Soils having a high infiltration rate (low runoff potential) when thoroughly wet. These consist mainly of deep, well drained to excessively drained sands or gravelly sands. These soils have a high rate of water transmission. Group B. Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture. These soils have a moderate rate of water transmission. Group C. Soils having a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Group D. Soils having a very slow infiltration rate (high runoff potential) when thoroughly wet. These consist chiefly of clays that have a high shrink-swell potential, soils that have a high water table, soils that have a claypan or clay layer at or near the surface, and soils that are shallow over nearly impervious material. These soils have a very slow rate of water transmission. If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is for drained areas and the second is for undrained areas. Only the soils that in their natural condition are in group D are assigned to dual classes. Rating Options Aggregation Method: Dominant Condition Hydrologic Soil Group—Larimer County Area, Colorado Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 10/14/2015 Page 3 of 4 Component Percent Cutoff: None Specified Tie-break Rule: Higher Hydrologic Soil Group—Larimer County Area, Colorado Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 10/14/2015 Page 4 of 4 Storm drain sized for 100 yr (33.5 cfs) developed flows from Village on Redwood site Assumed developed flows from Village on Redwood site, referenced for existing storm drain sizing (100-yr = 33.5cfs) B APPENDIX B — RATIONAL CALCULATIONS FCHA - Villages on Redwood DRAINAGE SUMMARY Design Engineer: Design Firm: Project Number: Date: DRAINAGE SUMMARY: Area (acres) % Imprevious 100-yr Peak Runoff (cfs) Area (acres) % Imprevious 100-yr Peak Runoff (cfs) To Redwood 6.217 4.4% 14.10 5.983 52.3% 26.92 H1 compared to D1+...D6 To Existing Pond 3.785 0.0% 11.45 4.020 1.4% 12.33 H2+OF1 compared to D7+OF1 Totals 10.002 2.7% 25.56 10.002 32.4% 39.25 T.Alva Interwest Consulting Group 1237-112-00 October 14, 2015 Basins Notes Historical Developed FCHA - Villages on Redwood HISTORIC IMPERVIOUS AREA CALCULATION Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA: Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 (Revised August 2006) BASINS: % Impervious Runoff Coefficient C Return Period Frequency Adjustment Factor (Cf ) 100% 0.95 2-year to 10-year 1.00 90% 0.95 100-year 1.25 90% 0.95 40% 0.50 0% 0.25 C2 to C10 C100 H1 270,830 6.217 11,888 0 0 0 258,941 4.4% 0.28 0.35 H2 162,764 3.737 0 0 0 0 162,764 0.0% 0.25 0.31 OF1 2,110 0.048 0 0 0 0 2,110 0.0% 0.25 0.31 Total 435,704 10.002 11,888 0 0 0 423,816 2.7% 0.27 0.34 Pavers Walks Apaved (sq feet) Lawns (Heavy, 2-7% Slope) Weighted % COMPOSITE Impervious 1237-112-00 Interwest Consulting Group T.Alva October 14, 2015 Sub-basin Designation Atotal (sq feet) Atotal (acres) % Impervious values from Table RO-3 in the Urban Storm Drainage Criteria Manual Runoff Coefficients and Frequency Adjustment Factors for City of Fort Collins - Storm Water Criteria Manual Land Use Paved Roof Alawn (sq feet) Apavers FCHA - Villages on Redwood HISTORIC TIME OF CONCENTRATION Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA: Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 (Revised August 2006) EQUATIONS: -Equation RO-3 -Equation RO-4 -Urbanized Check Equation RO-5 -Equation RO-3 CONSTRAINTS: 300 ft - Overland flow shall not exceed for developed condition 500 ft - Overland flow shall not exceed for undeveloped condition Final t c = minimum of t i + t t and urbanized basin check recommended minimum t c = 5 min for urbanized basins BASINS: Type of Travel Surface Cv H1 H1 0.28 6.217 419 0.0043 40.72 495 0.0059 Paved Areas 20 1.54 5.37 46.09 15.08 15.08 H2 H2 0.25 3.737 32 0.2582 3.00 0 0.0001 Tilage/Field 5 0.05 0.00 5.00 10.18 5.00 All Overland Flow OF1 OF1 0.25 0.048 15 0.0802 3.06 38 0.0251 Tilage/Field 5 0.79 0.81 5.00 10.30 5.00 SUB-BASIN DATA INITIAL/OVERLAND TIME (ti ) T.Alva Interwest Consulting Group 1237-112-00 October 14, 2015 DESIGN POINT Sub-basin C5 AREA (acres) LENGTH (ft) SLOPE (ft/ft) ti (min) LENGTH Table RO-2 (ft) TRAVEL TIME (tt ) REMARKS tc Urban Check Final tc (min) tc =ti +tt SLOPE (min) (ft/ft) VEL. (ft/s) tt FCHA - Villages on Redwood HISTORIC PEAK RUNOFF Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA: Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 (Revised August 2006) EQUATIONS: Q n = n -yr peak discharge (cfs) I = rainfall intensity (in/hr) P 1-5yr = 1.14 in C n = n -yr runoff coefficient P 1 = one-hour point rainfall depth (in) P 1-100yr = 2.86 in I n = n -yr rainfall intensity (in/hr) t c = time of concentration (min) P 1-10yr = 1.40 in A n = Basin drainage area (ac) BASINS: Runoff Coeff. (C5 ) C(A) (acres) Intensity (in/hr) Q (ft 3 /s) Runoff Coeff. (C5 ) C(A) (acres) Intensity (in/hr) Q (ft 3 /s) Runoff Coeff. (C100 ) C(A) (acres) Intensity (in/hr) Q (ft 3 /s) H1 H1 6.217 15.08 0.28 1.75 2.58 4.50 0.28 1.75 6.46 11.28 0.35 2.18 6.46 14.10 H2 H2 3.737 5.00 0.25 0.93 3.86 3.61 0.25 0.93 9.68 9.05 0.31 1.17 9.68 11.31 OF1 OF1 0.048 5.00 0.25 0.01 3.86 0.05 0.25 0.01 9.68 0.12 0.31 0.02 9.68 0.15 5-yr Peak Runoff 10-yr Peak Runoff 100-yr Peak Runoff T.Alva Interwest Consulting Group 1237-112-00 October 14, 2015 City of Fort Collins - Storm Water Criteria Manual (1997) Design Point Sub-basin Area (acres) tc (min) Q n = C n I n A n 0.786651) 1 ( 10 ) FCHA - Villages on Redwood DEVELOPED IMPERVIOUS AREA CALCULATION Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA: Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 (Revised August 2006) BASINS: % Impervious Runoff Coefficient C Return Period Frequency Adjustment Factor (Cf ) 100% 0.95 2-year to 10-year 1.00 90% 0.95 100-year 1.25 90% 0.95 40% 0.50 0% 0.25 C2 to C10 C100 D1 56,993 1.308 12,612 11,987 7,688 1,783 22,924 54.4% 0.65 0.82 D2 31,622 0.726 5,422 7,283 4,383 5,115 9,420 56.8% 0.67 0.84 D3 39,575 0.909 0 5,212 17,663 0 16,700 52.0% 0.65 0.82 D4 43,270 0.993 11,976 10,161 5,206 4,278 11,650 63.6% 0.72 0.90 D5 41,915 0.962 7,156 5,710 2,547 0 26,502 34.8% 0.51 0.63 D6 47,238 1.084 16,675 3,986 7,526 0 19,051 57.2% 0.67 0.83 D7 174,015 3.995 0 2,185 523 0 171,307 1.4% 0.26 0.33 OF1 1,076 0.025 0 0 0 0 1,076 0.0% 0.25 0.31 Total 435,704 10.002 53,841 46,524 45,535 11,175 278,629 32.4% 0.49 0.61 Inlet 02 (D1+D2+D3) 128,190 2.943 18,034 24,482 29,733 6,897 49,043 54.3% 0.66 0.82 Inlet 01 (D1+D2+D3+D4) 171,461 3.936 30,010 34,643 34,939 11,175 60,693 56.6% 0.67 0.84 To Redwood 260,614 5.983 53,841 44,340 45,012 11,175 106,246 53.2% 0.65 0.81 Sub-basin Designation Paved Pavers Land Use Atotal (sq feet) Atotal (acres) Walks Lawns (Heavy, 2- 7% Slope) Weighted % Impervious COMPOSITE Roof Apaved (sq feet) FCHA - Villages on Redwood DEVELOPED IMPERVIOUS AREA CALCULATION Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA: Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 (Revised August 2006) BASINS: % Impervious Runoff Coefficient C Return Period Frequency Adjustment Factor (Cf) 100% 0.95 2-year to 10-year 1.00 90% 0.95 100-year 1.25 90% 0.95 40% 0.50 0% 0.25 C2 to C10 C100 D1 56,993 1.308 12,612 11,987 7,688 1,783 22,924 54.4% 0.65 0.82 D2 31,622 0.726 5,422 7,283 4,383 5,115 9,420 56.8% 0.67 0.84 D3 39,575 0.909 0 5,212 17,663 0 16,700 52.0% 0.65 0.82 D4 43,270 0.993 11,976 10,161 5,206 4,278 11,650 63.6% 0.72 0.90 D5 41,915 0.962 7,156 5,710 2,547 0 26,502 34.8% 0.51 0.63 D6 47,238 1.084 16,675 3,986 7,526 0 19,051 57.2% 0.67 0.83 D7 174,015 3.995 0 2,185 523 0 171,307 1.4% 0.26 0.33 OF1 1,076 0.025 0 0 0 0 1,076 0.0% 0.25 0.31 Total 435,704 10.002 53,841 46,524 45,535 11,175 278,629 32.4% 0.49 0.61 Inlet 02 (D1+D2+D3) 128,190 2.943 18,034 24,482 29,733 6,897 49,043 54.3% 0.66 0.82 Inlet 01 (D1+D2+D3+D4) 171,461 3.936 30,010 34,643 34,939 11,175 60,693 56.6% 0.67 0.84 To Outlet Headwall 213,376 4.898 37,166 40,354 37,486 11,175 87,195 52.3% 0.64 0.80 To Redwood 260,614 5.983 53,841 44,340 45,012 11,175 106,246 53.2% 0.65 0.81 Basin D3 to ROW 27,055 0.621 2,671 4,612 3,982 0 15,790 38.5% 0.54 0.68 % Impervious values from Table RO-3 in the Urban Storm Drainage Criteria Manual Runoff Coefficients and Frequency Adjustment Factors for City of Fort Collins - Storm Water Criteria Manual T.Alva Interwest Consulting Group 1237-112-00 October 14, 2015 Weighted % Impervious COMPOSITE Roof Apaved (sq feet) Aroof (sq feet) Awalk (sq feet) Apavers (sq feet) Alawn FCHA - Villages on Redwood DEVELOPED TIME OF CONCENTRATION Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA: Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 (Revised August 2006) EQUATIONS: -Equation RO-2 -Equation RO-4 -Urbanized Check Equation RO-5 -Equation RO-3 CONSTRAINTS: 300 ft - Overland flow shall not exceed for developed condition 500 ft - Overland flow shall not exceed for undeveloped condition Final t c = minimum of t i + t t and urbanized basin check recommended minimum t c = 5 min for urbanized basins BASINS: Type of Travel Surface Cv D1 D1 0.65 1.308 21 0.0446 2.29 529 0.0068 Paved Areas 20 1.65 5.34 7.63 13.05 7.63 D2 D2 0.67 0.726 78 0.0268 5.02 156 0.0063 Paved Areas 20 1.59 1.63 6.65 11.30 6.65 D3 D3 0.65 0.909 82 0.0443 4.51 140 0.0116 Paved Areas 20 2.15 1.08 5.59 11.23 5.59 D4 D4 0.72 0.993 41 0.0701 2.34 255 0.0093 Paved Areas 20 1.93 2.20 5.00 11.64 5.00 D5 D5 0.51 0.962 44 0.0281 5.11 82 0.0130 Paved Areas 20 2.28 0.60 5.71 10.70 5.71 D6 D6 0.67 1.084 13 0.1729 1.13 568 0.0038 Paved Areas 20 1.23 7.70 8.82 13.23 8.82 D7 D7 0.26 3.995 37 0.0513 5.44 0 0.0001 Paved Areas 20 0.20 0.00 5.44 10.21 5.44 All Overland Flow OF1 OF1 0.25 0.025 6 0.1371 1.66 0 0.0001 Paved Areas 20 0.20 0.00 5.00 10.04 5.00 All Overland Flow TRAVEL TIME (tt) REMARKS tc Urban Check Final tc (min) tc =ti +tt SLOPE (min) (ft/ft) VEL. (ft/s) tt (min) T.Alva Interwest Consulting Group 1237-112-00 October 14, 2015 SLOPE (ft/ft) ti (min) LENGTH Table RO-2 (ft) SUB-BASIN DATA INITIAL/OVERLAND TIME (ti) DESIGN POINT Sub-basin C5 FCHA - Villages on Redwood DEVELOPED PEAK RUNOFF Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA: Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 (Revised August 2006) EQUATIONS: Q n = n -yr peak discharge (cfs) I = rainfall intensity (in/hr) P 1-5yr = 1.14 in C n = n -yr runoff coefficient P 1 = one-hour point rainfall depth (in) P 1-10yr = 1.40 in I n = n -yr rainfall intensity (in/hr) t c = time of concentration (min) P 1-100yr = 2.86 in A n = Basin drainage area (ac) BASINS: Runoff Coeff. (C5) C(A) (acres) Intensity (in/hr) Q (ft3/s) Runoff Coeff. (C5) C(A) (acres) Intensity (in/hr) Q (ft3/s) Runoff Coeff. (C100) C(A) (acres) Intensity (in/hr) Q (ft3/s) D1 D1 1.308 7.63 0.65 0.86 3.40 2.91 0.65 0.86 4.17 3.57 0.82 1.07 8.53 9.13 D2 D2 0.726 6.65 0.67 0.49 3.56 1.73 0.67 0.49 4.37 2.12 0.84 0.61 8.92 5.41 D3 D3 0.909 5.59 0.65 0.59 3.74 2.23 0.65 0.59 4.60 2.73 0.82 0.74 9.39 6.98 D4 D4 0.993 5.00 0.72 0.71 3.86 2.75 0.72 0.71 4.74 3.38 0.90 0.89 9.68 8.62 D5 D5 0.962 5.71 0.51 0.49 3.72 1.82 0.51 0.49 4.57 2.23 0.63 0.61 9.34 5.70 D6 D6 1.084 8.82 0.67 0.72 3.23 2.34 0.67 0.72 3.97 2.87 0.83 0.91 8.10 7.33 D7 D7 3.995 5.44 0.26 1.04 3.77 3.93 0.26 1.04 4.63 4.83 0.33 1.30 9.47 12.33 OF1 OF1 0.025 5.00 0.25 0.01 3.86 0.02 0.25 0.01 4.74 0.03 0.31 0.01 9.68 0.07 100-yr Peak Runoff T.Alva Interwest Consulting Group 1237-112-00 October 14, 2015 Design Point Sub-basin Area (acres) tc (min) 5-yr Peak Runoff 10-yr Peak Runoff City of Fort Collins - Storm Water Criteria Manual (1997) Q n = C n I n A n 0.786651) 1 ( 10 ) 28 . 5 t c P FCHA - Villages at Redwood Attenuated Flows for Pipe Sizing Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA: Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 EQUATIONS: -Equation RO-2 -Equation RO-4 -Equation RO-3 CONSTRAINTS: 300 ft - Overland flow shall not exceed for developed condition Final t c = minimum of t i + t t and urbanized basin check 500 ft - Overland flow shall not exceed for undeveloped condition recommended minimum t c = 5 min for urbanized basins Qn = n -yr peak discharge (cfs) I = rainfall intensity (in/hr) Cn = n -yr runoff coefficient P1 = one-hour point rainfall depth (in) In = n -yr rainfall intensity (in/hr) tc = time of concentration (min) A = drainage area (ac) P1-5yr = 1.14 in. P1-10yr = 1.40 in. P1-100yr = 2.86 in. BASINS: UD-Sewer - DP/Manhole Inlet 02 Contributing Basins D1+D2+D3 Contributing Area (acres) 2.94 C2 to C10 C100 Runoff Coefficients 0.66 0.82 Overland Flow Time Length (ft) 21 Slope (ft/ft) 0.04 ti (min) 2.27 Travel Time Length (ft) Slope (%) Type of Travel Surface Cv Velocity (ft/s) tt (min) 529 0.68% Paved Areas 20 1.65 5.35 108 0.25% Paved Areas 20 1.00 1.80 Total Time 7.15 Final Time of Concentration - tc (min) tc (min) 9.42 Intensities (in/hr) 5-yr 10-yr 100-yr 3.15 3.87 7.90 Discharge (cfs) 5-yr 10-yr 100-yr 6.10 7.49 19.13 T.Alva Interwest Consulting Group 1237-112-00 October 14, 2015 City of Fort Collins - Storm Water Criteria Manual (1997) Q n = C n I n A t c = t i + t t 0 . 5 V = C v S w V L tt 60 = ( ) FCHA - Villages at Redwood Attenuated Flows for Pipe Sizing Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA: Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 EQUATIONS: -Equation RO-2 -Equation RO-4 -Equation RO-3 CONSTRAINTS: 300 ft - Overland flow shall not exceed for developed condition Final t c = minimum of t i + t t and urbanized basin check 500 ft - Overland flow shall not exceed for undeveloped condition recommended minimum t c = 5 min for urbanized basins Qn = n -yr peak discharge (cfs) I = rainfall intensity (in/hr) Cn = n -yr runoff coefficient P1 = one-hour point rainfall depth (in) In = n -yr rainfall intensity (in/hr) tc = time of concentration (min) A = drainage area (ac) P1-5yr = 1.14 in. P1-10yr = 1.40 in. P1-100yr = 2.86 in. BASINS: UD-Sewer - DP/Manhole Inlet 01 Contributing Basins D1+D2+D3+D4 Contributing Area (acres) 3.94 C2 to C10 C100 Runoff Coefficients 0.67 0.84 Overland Flow Time Length (ft) 21 Slope (ft/ft) 0.05 ti (min) 2.17 Travel Time Length (ft) Slope (%) Type of Travel Surface Cv Velocity (ft/s) tt (min) 529 0.68% Paved Areas 20 1.65 5.35 108 0.25% Paved Areas 20 1.00 1.80 102 0.25% Paved Areas 20 1.00 1.69 57 0.25% Paved Areas 20 1.00 0.94 Total Time 9.79 Final Time of Concentration - tc (min) tc (min) 11.96 Intensities (in/hr) 5-yr 10-yr 100-yr 2.86 3.51 7.18 Discharge (cfs) 5-yr 10-yr 100-yr 7.58 9.30 23.76 T.Alva Interwest Consulting Group 1237-112-00 October 14, 2015 City of Fort Collins - Storm Water Criteria Manual (1997) Q n = C n I n A t c = t i + t t 0 . 5 V = C v S w V L tt 60 FCHA - Villages at Redwood Attenuated Flows for Pipe Sizing Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA: Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 EQUATIONS: -Equation RO-2 -Equation RO-4 -Equation RO-3 CONSTRAINTS: 300 ft - Overland flow shall not exceed for developed condition Final t c = minimum of t i + t t and urbanized basin check 500 ft - Overland flow shall not exceed for undeveloped condition recommended minimum t c = 5 min for urbanized basins Qn = n -yr peak discharge (cfs) I = rainfall intensity (in/hr) Cn = n -yr runoff coefficient P1 = one-hour point rainfall depth (in) In = n -yr rainfall intensity (in/hr) tc = time of concentration (min) A = drainage area (ac) P1-5yr = 1.14 in. P1-10yr = 1.40 in. P1-100yr = 2.86 in. BASINS: UD-Sewer - DP/Manhole To Redwood Contributing Basins D1+D2+D3+D4+D5 Contributing Area (acres) 4.90 C2 to C10 C100 Runoff Coefficients 0.64 0.80 Overland Flow Time Length (ft) 21 Slope (ft/ft) 0.05 ti (min) 2.33 Travel Time Length (ft) Slope (%) Type of Travel Surface Cv Velocity (ft/s) tt (min) 529 0.68% Paved Areas 20 1.65 5.35 108 0.25% Paved Areas 20 1.00 1.80 102 0.25% Paved Areas 20 1.00 1.69 57 0.25% Paved Areas 20 1.00 0.94 94 0.50% Paved Areas 20 1.41 1.11 pan from fes to headwall Total Time 10.89 Final Time of Concentration - tc (min) tc (min) 13.23 Intensities (in/hr) 5-yr 10-yr 100-yr 2.74 3.36 6.86 Discharge (cfs) 5-yr 10-yr 100-yr 8.58 10.54 26.92 T.Alva Interwest Consulting Group 1237-112-00 October 14, 2015 City of Fort Collins - Storm Water Criteria Manual (1997) Q n = C n I n A t c = t i + t t 0 . 5 V = C v S w V L C APPENDIX C — STORM DRAIN SIZING D APPENDIX D — DETENTION POND CALCULATIONS Project: Basin ID: Design Information (Input): Design Information (Input): Catchment Drainage Imperviousness Ia = 52.30 percent Catchment Drainage Imperviousness I a = 52.30 percent Catchment Drainage Area A = 4.900 acres Catchment Drainage Area A = 4.900 acres Predevelopment NRCS Soil Group Type = C A, B, C, or D Predevelopment NRCS Soil Group Type = C A, B, C, or D Return Period for Detention Control T = 5 years (2, 5, 10, 25, 50, or 100) Return Period for Detention Control T = 100 years (2, 5, 10, 25, 50, or 100) Time of Concentration of Watershed Tc = 13 minutes Time of Concentration of Watershed Tc = 13 minutes Allowable Unit Release Rate q = 1.38 cfs/acre Allowable Unit Release Rate q = 1.38 cfs/acre One-hour Precipitation P1 = 1.14 inches One-hour Precipitation P 1 = 2.86 inches Design Rainfall IDF Formula i = C1* P 1/(C2 +Tc)^C 3 Design Rainfall IDF Formula i = C1 * P1/(C 2+Tc )^C3 Coefficient One C1 = 28.50 Coefficient One C 1 = 28.50 Coefficient Two C2 = 10 Coefficient Two C 2 = 10 Coefficient Three C3 = 0.787 Coefficient Three C 3 = 0.787 Determination of Average Outflow from the Basin (Calculated): Determination of Average Outflow from the Basin (Calculated): Runoff Coefficient C = 0.41 Runoff Coefficient C = 0.61 Inflow Peak Runoff Qp-in = 5.50 cfs Inflow Peak Runoff Qp-in = 20.52 cfs Allowable Peak Outflow Rate Qp-out = 6.76 cfs Allowable Peak Outflow Rate Qp-out = 6.76 cfs Mod. FAA Minor Storage Volume = 298 cubic feet Mod. FAA Major Storage Volume = 16,352 cubic feet Mod. FAA Minor Storage Volume = 0.007 acre-ft Mod. FAA Major Storage Volume = 0.375 acre-ft 5 <- Enter Rainfall Duration Incremental Increase Value Here (e.g. 5 for 5-Minutes) Rainfall Rainfall Inflow Adjustment Average Outflow Storage Rainfall Rainfall Inflow Adjustment Average Outflow Storage Duration Intensity Volume Factor Outflow Volume Volume Duration Intensity Volume Factor Outflow Volume Volume minutes inches / hr acre-feet "m" cfs acre-feet acre-feet minutes inches / hr acre-feet "m" cfs acre-feet acre-feet (input) (output) (output) (output) (output) (output) (output) (input) (output) (output) (output) (output) (output) (output) 0 0.00 0.000 0.00 0.00 0.000 0.000 0 0.00 0.000 0.00 0.00 0.000 0.000 5 3.86 0.053 1.00 6.76 0.047 0.007 5 9.68 0.199 1.00 6.76 0.047 0.153 10 3.08 0.085 1.00 6.76 0.093 -0.008 10 7.72 0.318 1.00 6.76 0.093 0.225 15 2.58 0.107 0.94 6.36 0.131 -0.024 15 6.48 0.400 0.94 6.36 0.131 0.269 20 2.24 0.124 0.83 5.62 0.155 -0.031 20 5.61 0.462 0.83 5.62 0.155 0.307 25 1.98 0.137 0.76 5.17 0.178 -0.041 25 4.97 0.512 0.76 5.17 0.178 0.334 30 1.78 0.148 0.72 4.87 0.201 -0.053 30 4.48 0.553 0.72 4.87 0.201 0.352 35 1.63 0.158 0.69 4.66 0.225 -0.067 35 4.08 0.588 0.69 4.66 0.225 0.363 40 1.50 0.166 0.67 4.50 0.248 -0.082 40 3.76 0.619 0.67 4.50 0.248 0.371 45 1.39 0.173 0.65 4.38 0.271 -0.098 45 3.48 0.646 0.65 4.38 0.271 0.374 50 1.30 0.179 0.63 4.28 0.294 -0.115 50 3.25 0.670 0.63 4.28 0.294 0.375 55 1.22 0.185 0.62 4.19 0.318 -0.132 55 3.06 0.692 0.62 4.19 0.318 0.374 60 1.15 0.191 0.61 4.13 0.341 -0.150 60 2.88 0.712 0.61 4.13 0.341 0.371 65 1.09 0.196 0.60 4.07 0.364 -0.169 65 2.73 0.731 0.60 4.07 0.364 0.366 70 1.03 0.200 0.59 4.02 0.388 -0.187 70 2.60 0.748 0.59 4.02 0.388 0.360 75 0.99 0.205 0.59 3.98 0.411 -0.206 75 2.47 0.764 0.59 3.98 0.411 0.353 80 0.94 0.209 0.58 3.94 0.434 -0.225 80 2.37 0.779 0.58 3.94 0.434 0.345 85 0.90 0.213 0.58 3.91 0.457 -0.245 85 2.27 0.793 0.58 3.91 0.457 0.336 90 0.87 0.216 0.57 3.88 0.481 -0.265 90 2.18 0.807 0.57 3.88 0.481 0.326 95 0.84 0.220 0.57 3.85 0.504 -0.284 95 2.10 0.820 0.57 3.85 0.504 0.315 100 0.81 0.223 0.57 3.83 0.527 -0.305 100 2.02 0.832 0.57 3.83 0.527 0.304 105 0.78 0.226 0.56 3.81 0.551 -0.325 105 1.95 0.843 0.56 3.81 0.551 0.293 110 0.75 0.229 0.56 3.79 0.574 -0.345 110 1.89 0.854 0.56 3.79 0.574 0.280 115 0.73 0.232 0.56 3.77 0.597 -0.365 115 1.83 0.865 0.56 3.77 0.597 0.268 Project: Basin ID: DETENTION VOLUME BY THE MODIFIED FAA METHOD FCHA - Villages at Redwood UDFCD DETENTION BASIN VOLUME ESTIMATING WORKBOOK Version 2.35, Released January 2015 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 0 50 100 150 200 250 300 350 Volume (acre-feet) Duration (Minutes) Inflow and Outflow Volumes vs. Rainfall Duration Minor Storm Inflow Volume Minor Storm Outflow Volume Minor Storm Storage Volume Major Storm Inflow Volume Major Storm Outflow Volume Major Storm Storage Volume 1237-112-00 UD-Detention_v2.35.xls, Modified FAA 10/14/2015, 2:06 PM Village on Redwood Critical Pond Elevations (Basin D1) Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA Urban Storm Drainage Criteria Manual, Urban Drainage and Flood Control District, June 2001 (Revised April 2008) Stage Storage Volume (pond volume calculated using the prismoidal formula): CONTOUR (FT) AREA (FT2) AREA (ACRE) VOLUME (ACRE-FT) DEPTH (FT) CUMULATIVE VOLUME (ACRE-FT) 4962.38 0 0.000 0.000 0.00 0.000 4963.0 2517 0.058 0.012 0.62 0.012 4964.0 6693 0.154 0.102 1.62 0.114 4965.0 9740 0.224 0.188 2.62 0.301 4966.0 12947 0.297 0.260 3.62 0.561 0.38 4965.28 ft T.Alva Interwest Consulting Group 1237-112-00 Acre-Ft Interpolates to an Elev. of Acre-Ft Interpolates to an Elev. of Required Water Quality Capture Volume =0 Required 100-yr Detention Volume (including WQCV) = October 14, 2015 4962.00 4962.50 4963.00 4963.50 4964.00 4964.50 4965.00 4965.50 4966.00 4966.50 0.0 0.1 0.2 0.3 0.4 0.5 0.6 ELEVATION (FT) DETENTION POND VOLUME (AC-FT) DETENTION POND VOLUME VERSUS ELEVATION ( ) 3 AAAADepth 1 2 1 2 V + + = 1237-112-00 PondCalcs.xls - Pond Stage Storage Page 1 of 1 Interwest Consulting Group E APPENDIX E — LOW IMPACT DEVELOPMENT CALCULATIONS FCHA - Villages on Redwood Low Impact Development Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA Low Impact Development Summary Pavement Area Summary 43,661 sqft 11,194 sqft 25.6% Newly Added Impervious Area Summary 128,515 sqft 11,194 sqft 30,431 sqft 41,625 sqft 22,632 sqft 64,258 sqft 50.0% Urban Storm Drainage Criteria Manual, Urban Drainage and Flood Control District, January 2010 Total Paved Area: Permeable Paver Area: Total Site Impervious Area: Proposed Area of Pavers: Additional Area Treated by Pavers: Total Area Treated by Pavers: Area to be Treated by Sand Filter: Total Area Treated by LID: Percent Impervious Area Treated by LID: Percent Pavement Area as Permeable Pavers: City of Fort Collins - Ordinance No. 152 - No less than 25% of any newly added pavement areas must be treated using a permeable pavement technology that is considered an LID Technique, and - No less than 50% of any newly added impervious area must be treated using one or a combination of LID techniques T.Alva Interwest Consulting Group 1237-112-00 October 14, 2015 Sheet 1 of 2 Designer: Company: Date: Project: Location: 1. Basin Storage Volume A) Effective Imperviousness of Tributary Area, Ia Ia = 100.0 % (100% if all paved and roofed areas upstream of sand filter) B) Tributary Area's Imperviousness Ratio (i = Ia/100) i = 1.000 C) Water Quality Capture Volume (WQCV) Based on 12-hour Drain Time WQCV = 0.45 watershed inches WQCV= 0.9 * (0.91* i3 - 1.19 * i2 + 0.78 * i) D) Contributing Watershed Area (including sand filter area) Area = 22,633 sq ft E) Water Quality Capture Volume (WQCV) Design Volume VWQCV = 849 cu ft VWQCV = WQCV / 12 * Area F) For Watersheds Outside of the Denver Region, Depth of d6 = 0.43 in Average Runoff Producing Storm G) For Watersheds Outside of the Denver Region, VWQCV OTHER = 849 cu ft Water Quality Capture Volume (WQCV) Design Volume H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER = 850 cu ft (Only if a different WQCV Design Volume is desired) 2. Basin Geometry A) WQCV Depth DWQCV = 1.0 ft B) Sand Filter Side Slopes (Horizontal distance per unit vertical, Z = 4.00 ft / ft 4:1 or flatter preferred). Use "0" if sand filter has vertical walls. C) Mimimum Filter Area (Flat Surface Area) AMin = 189 sq ft D) Actual Filter Area AActual = 850 sq ft E) Volume Provided VT = 850 cu ft 3. Filter Material 4. Underdrain System A) Are underdrains provided? B) Underdrain system orifice diameter for 12 hour drain time i) Distance From Lowest Elevation of the Storage y = N/A ft Volume to the Center of the Orifice ii) Volume to Drain in 12 Hours Vol12 = N/A cu ft iii) Orifice Diameter, 3/8" Minimum DO = N/A in Village on Redwood Fort Collins, CO Design Procedure Form: Sand Filter (SF) J.Claeys Interwest Consulting Group October 14, 2015 Choose One Choose One 18" CDOT Class C Filter Material Other (Explain): YES NO 1237-112-00 UD-BMP_v3.03.xlsm, SF 10/14/2015, 11:29 AM Sheet 2 of 2 Designer: Company: Date: Project: Location: 5. Impermeable Geomembrane Liner and Geotextile Separator Fabric A) Is an impermeable liner provided due to proximity of structures or groundwater contamination? 6-7. Inlet / Outlet Works A) Describe the type of energy dissipation at inlet points and means of conveying flows in excess of the WQCV through the outlet Notes: Full Infiltration Design Procedure Form: Sand Filter (SF) J.Claeys Interwest Consulting Group October 14, 2015 Village on Redwood Fort Collins, CO Choose One YES NO 1237-112-00 UD-BMP_v3.03.xlsm, SF 10/14/2015, 11:29 AM Percolation Test Results DEPTH DEPTH PERC PERC MINUTES START END CHANGE RATE HOLE (INCHES) (INCHES) (INCHES) (MPI) 1 10 22.88 24.75 1.88 5.3 10 24.75 26.25 1.50 6.7 10 26.25 27.50 1.25 8.0 10 27.50 28.63 1.13 8.9 10 28.63 29.75 1.13 8.9 10 29.75 30.88 1.13 8.9 10 20.50 22.38 1.88 5.3 10 22.38 24.13 1.75 5.7 2* 10 19.38 19.38 0.00 >80 10 19.38 19.50 0.13 80.0 10 19.50 19.50 0.00 >80 10 19.50 19.63 0.13 80.0 10 19.63 19.75 0.13 80.0 10 19.75 19.75 0.00 >80 10 19.75 19.88 0.13 80.0 10 19.88 20.00 0.13 80.0 3 10 20.25 22.00 1.75 5.7 10 22.00 23.63 1.63 6.2 10 23.63 25.25 1.63 6.2 10 25.25 26.63 1.38 7.3 10 26.63 27.88 1.25 8.0 10 27.88 29.25 1.38 7.3 10 29.25 30.13 0.88 11.4 10 30.13 31.00 0.88 11.4 4 10 17.25 18.63 1.38 7.3 10 18.63 19.88 1.25 8.0 10 19.78 21.00 1.22 8.2 10 21.00 22.00 1.00 10.0 10 22.00 23.13 1.13 8.9 10 23.13 24.00 0.88 11.4 10 24.00 24.88 0.88 11.4 10 16.88 18.00 1.13 8.9 5 10 22.00 24.25 2.25 4.4 10 24.25 26.38 2.13 4.7 10 26.38 28.25 1.88 5.3 10 28.25 29.88 1.63 6.2 10 29.88 31.25 1.38 7.3 10 31.25 32.63 1.38 7.3 10 32.63 33.88 1.25 8.0 10 33.88 35.13 1.25 8.0 6 10 22.88 31.25 8.38 1.2 10 31.25 38.00 6.75 1.5 10 28.25 35.25 7.00 1.4 10 35.25 41.75 6.50 1.5 10 41.75 45.00 3.25 3.1 10 21.75 30.50 8.75 1.1 10 30.50 37.63 7.13 1.4 10 37.63 41.63 4.00 2.5 Average Percolation Rate (mpi): 8.6 *Perc hole 2 was neglected for our average percolation rate INTERWEST CONSULTING GROUP FCHA REDWOOD DEVELOPMENT CTL | T PROJECT NO. FC06667.001-130 FIGURE 3 120 0.71 0.234 0.56 3.75 0.620 -0.386 120 1.77 0.875 0.56 3.75 0.620 0.255 125 0.69 0.237 0.55 3.74 0.644 -0.407 125 1.72 0.885 0.55 3.74 0.644 0.241 130 0.67 0.240 0.55 3.73 0.667 -0.427 130 1.67 0.894 0.55 3.73 0.667 0.227 135 0.65 0.242 0.55 3.71 0.690 -0.448 135 1.63 0.903 0.55 3.71 0.690 0.213 140 0.63 0.244 0.55 3.70 0.714 -0.469 140 1.58 0.912 0.55 3.70 0.714 0.199 145 0.61 0.247 0.55 3.69 0.737 -0.490 145 1.54 0.921 0.55 3.69 0.737 0.184 150 0.60 0.249 0.54 3.68 0.760 -0.511 150 1.50 0.929 0.54 3.68 0.760 0.169 155 0.59 0.251 0.54 3.67 0.783 -0.532 155 1.47 0.937 0.54 3.67 0.783 0.154 160 0.57 0.253 0.54 3.66 0.807 -0.554 160 1.43 0.945 0.54 3.66 0.807 0.138 165 0.56 0.255 0.54 3.65 0.830 -0.575 165 1.40 0.952 0.54 3.65 0.830 0.122 170 0.55 0.257 0.54 3.64 0.853 -0.596 170 1.37 0.960 0.54 3.64 0.853 0.106 175 0.53 0.259 0.54 3.64 0.877 -0.618 175 1.34 0.967 0.54 3.64 0.877 0.090 180 0.52 0.261 0.54 3.63 0.900 -0.639 180 1.31 0.974 0.54 3.63 0.900 0.074 185 0.51 0.263 0.54 3.62 0.923 -0.660 185 1.29 0.981 0.54 3.62 0.923 0.057 190 0.50 0.265 0.53 3.62 0.946 -0.682 190 1.26 0.987 0.53 3.62 0.946 0.041 195 0.49 0.266 0.53 3.61 0.970 -0.703 195 1.24 0.994 0.53 3.61 0.970 0.024 200 0.48 0.268 0.53 3.60 0.993 -0.725 200 1.21 1.000 0.53 3.60 0.993 0.007 205 0.48 0.270 0.53 3.60 1.016 -0.747 205 1.19 1.006 0.53 3.60 1.016 -0.010 210 0.47 0.271 0.53 3.59 1.040 -0.768 210 1.17 1.012 0.53 3.59 1.040 -0.027 215 0.46 0.273 0.53 3.59 1.063 -0.790 215 1.15 1.018 0.53 3.59 1.063 -0.045 220 0.45 0.274 0.53 3.58 1.086 -0.812 220 1.13 1.024 0.53 3.58 1.086 -0.062 225 0.44 0.276 0.53 3.58 1.109 -0.834 225 1.11 1.030 0.53 3.58 1.109 -0.080 230 0.44 0.277 0.53 3.58 1.133 -0.855 230 1.09 1.035 0.53 3.58 1.133 -0.097 235 0.43 0.279 0.53 3.57 1.156 -0.877 235 1.08 1.041 0.53 3.57 1.156 -0.115 240 0.42 0.280 0.53 3.57 1.179 -0.899 240 1.06 1.046 0.53 3.57 1.179 -0.133 245 0.42 0.282 0.53 3.56 1.203 -0.921 245 1.04 1.052 0.53 3.56 1.203 -0.151 250 0.41 0.283 0.53 3.56 1.226 -0.943 250 1.03 1.057 0.53 3.56 1.226 -0.169 255 0.40 0.285 0.53 3.56 1.249 -0.965 255 1.01 1.062 0.53 3.56 1.249 -0.187 260 0.40 0.286 0.53 3.55 1.272 -0.987 260 1.00 1.067 0.53 3.55 1.272 -0.206 265 0.39 0.287 0.52 3.55 1.296 -1.009 265 0.98 1.072 0.52 3.55 1.296 -0.224 270 0.39 0.288 0.52 3.55 1.319 -1.031 270 0.97 1.077 0.52 3.55 1.319 -0.242 275 0.38 0.290 0.52 3.54 1.342 -1.053 275 0.96 1.082 0.52 3.54 1.342 -0.261 280 0.38 0.291 0.52 3.54 1.366 -1.075 280 0.94 1.086 0.52 3.54 1.366 -0.279 285 0.37 0.292 0.52 3.54 1.389 -1.097 285 0.93 1.091 0.52 3.54 1.389 -0.298 290 0.37 0.293 0.52 3.54 1.412 -1.119 290 0.92 1.095 0.52 3.54 1.412 -0.317 295 0.36 0.295 0.52 3.53 1.435 -1.141 295 0.91 1.100 0.52 3.53 1.435 -0.336 300 0.36 0.296 0.52 3.53 1.459 -1.163 300 0.89 1.104 0.52 3.53 1.459 -0.354 Mod. FAA Minor Storage Volume (cubic ft.) = 298 Mod. FAA Major Storage Volume (cubic ft.) = 16,352 Mod. FAA Minor Storage Volume (acre-ft.) = 0.0068 Mod. FAA Major Storage Volume (acre-ft.) = 0.3754 DETENTION VOLUME BY THE MODIFIED FAA METHOD FCHA - Villages at Redwood Determination of MAJOR Detention Volume Using Modified FAA Method (For catchments less than 160 acres only. For larger catchments, use hydrograph routing method) (NOTE: for catchments larger than 90 acres, CUHP hydrograph and routing are recommended) UDFCD DETENTION BASIN VOLUME ESTIMATING WORKBOOK Version 2.35, Released January 2015 Determination of MINOR Detention Volume Using Modified FAA Method 1237-112-00 UD-Detention_v2.35.xls, Modified FAA 10/14/2015, 2:06 PM tt 60 = ( ) 0 .33 0 . 395 1 . 1 5 S C L ti − = 0.786651) 1 ( 10 ) 28 . 5 t c P I + = = ( ) 0 .33 0 . 395 1 . 1 5 S C L ti − = 0.786651) 1 ( 10 ) 28 . 5 t c P I + = 0 .33 0 . 395 1 . 1 5 S C L ti − = 0.786651) 1 ( 10 ) 28 . 5 t c P I + = I + = AREA (acres) LENGTH (ft) ( ) 0 .33 5 0 . 395 1 . 1 S C L t i − = c i t t = t + t 0 . 5 v w V = C S 10 180 = + L t c V L t t 60 = (sq feet) Sub-basin Designation Paved Pavers Land Use Atotal (sq feet) Atotal (acres) Walks Lawns (Heavy, 2- 7% Slope) Aroof (sq feet) Awalk (sq feet) Apavers (sq feet) Alawn (sq feet) % Impervious values from Table RO-3 in the Urban Storm Drainage Criteria Manual Runoff Coefficients and Frequency Adjustment Factors for City of Fort Collins - Storm Water Criteria Manual T.Alva Interwest Consulting Group 1237-112-00 October 14, 2015 28 . 5 t c P I + = (min) ( ) 0 .33 5 0 . 395 1 . 1 S C L t i − = c i t t = t + t 0 . 5 v w V = C S 10 180 = + L t c V L t t 60 = (sq feet) Awalk (sq feet) Aroof (sq feet) Survey Area Data: Version 9, Sep 22, 2014 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Apr 22, 2011—Apr 28, 2011 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Hydrologic Soil Group—Larimer County Area, Colorado Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 10/14/2015 Page 2 of 4