Loading...
HomeMy WebLinkAboutTHE SLAB - PDP - PDP150016 - PLANS - ELEVATIONSSTEEL ARBOR - OFF-WHITE/BEIGE VINYL OR FIBERGLASS WINDOW - WHITE PRECAST SILL/BAND - OFF-WHITE/BEIGE PRECAST CAP - OFF-WHITE/BEIGE BUILT-UP FIBER CEMENT CORNICE - OFF-WHITE/BEIGE DECK RAIL - BLACK PRECAST WALL CAP - OFF-WHITE/BEIGE CONCRETE WINDOW WELL WALL PRECAST SILL/BAND - OFF-WHITE/BEIGE BUILT-UP FIBER CEMENT CORNICE - OFF-WHITE/BEIGE EW1 EW4 R4 M1 M2 R7 XW2 EW2 EW6 EW1 EW2 M2 EW3 M1 EW5 EW3 M3 EW1 EW3 M1 EW3 EW1 R2 R5 R4 R2 R5 R2 R5 EW3 R4 9" / 12" 4" / 12" 9" / 12" VINYL OR FIBERGLASS WINDOW - WHITE PRECAST BAND - OFF-WHITE/BEIGE 48' - 0" . R2 EW3 R4 M1 EW1 M2 EW3 EW5 EW6 M3 EW5 EW2 EW1.1 EW1.2 EW5 XW2 EW1 EW4 R5 PRECAST WALL CAP - OFF-WHITE/BEIGE BIKE SHELTER BIKE SHELTER EW2 EW1.2 EW5 EW4 R5 EW1 EW2 EW4 R2 R4 EW1 M1 M2 EW3 EW1 EW5 EW1 EW2 EW3 EW4 M2 EW2 EW5 EW4 EW3 9" / 12" 9" / 12" VINYL OR FIBERGLASS SLIDING DOOR - WHITE BIKE SHELTER 48' - 0" . PRECAST WALL CAP AT DECK - OFF-WHITE/BEIGE VINYL OR FIBERGLASS WINDOW - WHITE EW2.1 M2 EW3 EW5 EW4 R5 EW1 XW2 R2 XW2 EW2 R7 M1 EW6 EW1 M2 EW4 R4 R2 EW3 4" / 12" 9" / 12" ALL EXPOSED ELECTRICAL, PLUMBING, AND MECHANICAL EQUIPMENT AND METERS ARE TO BE SCREENED OR OTHERWISE PAINTED TO MATCH THE BUILDING. NOTE: PROJECT DATE DRAWN 712 WHALERS WAY SUITE, B-100 FORT COLLINS, CO 80525 (970) 223-1820 www.aller-lingle-massey.com PRINTED FILE NAME: NOT FOR CONSTRUCTION C alm2s 2015 10/7/2015 9:34:45 AM Fort Collins, Colorado 1520-Project-SD.rvt BUILDING ELEVATIONS 1520 ksj 10.07.15 PDP-2 808 W. Prospect Road The Slab Property NO ISSUE DATE 1 1/8" = 1'-0" PDP NORTH ELEVATION 2 1/8" = 1'-0" PDP EAST ELEVATION 3 PDP View from SouthEast SYSTEM NOTES - PDP ac NOTE EW1 4" nominal brick veneer (brownish red) on 2" air space with masonry anchors per 2 square feet minimum on Tyvek commercial building wrap over 7/16" OSB sheathing on 2x6 wall framing at 16" on center with R-23 loose fill fiberglass insulation. Vapor barrier and 5/8" gypsum board at interior side. Refer to architectural elevations for brick height, pattern, color, and control joint locations. EW1.2 4" nominal brick veneer (brownish red) on 1" air space with masonry anchors per 2 square feet minimum on both sides of 8" concrete... Refer to architectural elevations for brick height, pattern, color and control joint locations. EW2 Synthetic stone veneer (dark beige/gray) on masonry mortar on galvanized metal lath (anchored to wood stud framing) on 15 lb. asphalt impregnated building paper on Tyvek commercial building wrap over 7/16" OSB sheathing on 2x6 wall framing at 16" on center with R-23 loose fill fiberglass insulation. Vapor barrier and 5/8" gypsum board on interior side. Refer to architectural elevations for height and control joint locations. EW2.1 Synthetic stone veneer (dark beige/gray) on masonry mortar on galvanized metal lath (anchored to masonry wall) on both sides of 8" concrete masonry units. Refer to architectural elevations for height and control joint locations. EW3 Two-coat portland cement based stucco system (off-white/beige) on galvanized metal lath on stucco paper on Tyvek commercial building stucco wrap over 7/16" OSB sheathing on 2x6 wall framing at 16" on center with R-23 loose fill fiberglass insulation. Vapor barrier and 5/8" gypsum board at interior side. Refer to architectural elevations for stucco height, color and control joint locations. EW4 Cement fiber horizontal lap siding (blue-gray) with smooth texture and 6" exposure on Tyvek commercial building wrap over 7/16" OSB sheathing on 2x6 wall framing at 16" on center with R-23 loose fill fiberglass insulation. Vapor barrier and 5/8" gypsum board at interior side. Refer to architectural elevations for locations. EW5 Thermally broken anodized aluminum storefront system with double insulated glazing; mill finish. Refer to window elevations for tempered and spandrel glass locations and storefront schedule for configurations. EW6 New Area Well Wall - 10" thick concrete wall with reinforcing per structural with damproofing at exterior face below grade. Sack finish exterior of wall above grade. Provide new perimeter drain at base of wall to tie in with existing perimeter drain. M1 Tube steel brace, paint. Re. structural. M2 Decorative safety guardrail, paint. R2 30 year high profile architectural asphalt shingles (gray/beige) on 30 lbs asphalt impregnated building paper with full covereage Grace ice and water shield secondary underlayment on 15/32" OSB roof deck on pre-engineered trusses at 24" on center, re. structural. R-38 batt insulation at bottom chords of sloped trusse with 5/8" Type 'X" gypsum board at the underside. Provide insulation baffles at eave conditions. R4 6" x 6" pre-finished metal box-style gutter R5 3/4" thick Fiber Cement fascia over continuous 2x sub-fascia. Flat fascia at R2 roof system. Built up fascia at R1 roof system where applicable. R7 Canopy Roof - 30 year high profile architectural asphalt shingles (gray/beige) on 30 lbs asphalt impregnated building paper with full covereage Grace ice and water shield secondary underlayment on 15/32" OSB roof deck on framing per structural. XW2 Existing area well wall (field verify existing conditions) LOTS 1 & 2, OBSERVATORY PARK SUBDIVISION M1 R2 R5 EW3 9" / 12" 4" / 12" ALL EXPOSED ELECTRICAL, PLUMBING, AND MECHANICAL EQUIPMENT AND METERS ARE TO BE SCREENED OR OTHERWISE PAINTED TO MATCH THE BUILDING. NOTE: PROJECT DATE DRAWN 712 WHALERS WAY SUITE, B-100 FORT COLLINS, CO 80525 (970) 223-1820 www.aller-lingle-massey.com PRINTED FILE NAME: NOT FOR CONSTRUCTION C alm2s 2015 10/7/2015 9:34:26 AM Fort Collins, Colorado 1520-Project-SD.rvt BUILDING ELEVATIONS 1520 ksj 10.07.15 PDP-1 808 W. Prospect Road The Slab Property NO ISSUE DATE 1 1/8" = 1'-0" PDP SOUTH ELEVATION 2 1/8" = 1'-0" PDP WEST ELEVATION 3 PDP View from South West SYSTEM NOTES - PDP ac NOTE EW1 4" nominal brick veneer (brownish red) on 2" air space with masonry anchors per 2 square feet minimum on Tyvek commercial building wrap over 7/16" OSB sheathing on 2x6 wall framing at 16" on center with R-23 loose fill fiberglass insulation. Vapor barrier and 5/8" gypsum board at interior side. Refer to architectural elevations for brick height, pattern, color, and control joint locations. EW1.1 4" nominal brick veneer (brownish red) on 2" air space with masonry anchors per 2 square feet minimum on Tyvek commercial building wrap on 8" concrete masonry units. Refer to architectural elevations for brick height, pattern, color and control joint locations. EW1.2 4" nominal brick veneer (brownish red) on 1" air space with masonry anchors per 2 square feet minimum on both sides of 8" concrete... Refer to architectural elevations for brick height, pattern, color and control joint locations. EW2 Synthetic stone veneer (dark beige/gray) on masonry mortar on galvanized metal lath (anchored to wood stud framing) on 15 lb. asphalt impregnated building paper on Tyvek commercial building wrap over 7/16" OSB sheathing on 2x6 wall framing at 16" on center with R-23 loose fill fiberglass insulation. Vapor barrier and 5/8" gypsum board on interior side. Refer to architectural elevations for height and control joint locations. EW3 Two-coat portland cement based stucco system (off-white/beige) on galvanized metal lath on stucco paper on Tyvek commercial building stucco wrap over 7/16" OSB sheathing on 2x6 wall framing at 16" on center with R-23 loose fill fiberglass insulation. Vapor barrier and 5/8" gypsum board at interior side. Refer to architectural elevations for stucco height, color and control joint locations. EW4 Cement fiber horizontal lap siding (blue-gray) with smooth texture and 6" exposure on Tyvek commercial building wrap over 7/16" OSB sheathing on 2x6 wall framing at 16" on center with R-23 loose fill fiberglass insulation. Vapor barrier and 5/8" gypsum board at interior side. Refer to architectural elevations for locations. EW5 Thermally broken anodized aluminum storefront system with double insulated glazing; mill finish. Refer to window elevations for tempered and spandrel glass locations and storefront schedule for configurations. EW6 New Area Well Wall - 10" thick concrete wall with reinforcing per structural with damproofing at exterior face below grade. Sack finish exterior of wall above grade. Provide new perimeter drain at base of wall to tie in with existing perimeter drain. M1 Tube steel brace, paint. Re. structural. M2 Decorative safety guardrail, paint. M3 Tube steel arbor, paint. R2 30 year high profile architectural asphalt shingles (gray/beige) on 30 lbs asphalt impregnated building paper with full covereage Grace ice and water shield secondary underlayment on 15/32" OSB roof deck on pre-engineered trusses at 24" on center, re. structural. R-38 batt insulation at bottom chords of sloped trusse with 5/8" Type 'X" gypsum board at the underside. Provide insulation baffles at eave conditions. R4 6" x 6" pre-finished metal box-style gutter R5 3/4" thick Fiber Cement fascia over continuous 2x sub-fascia. Flat fascia at R2 roof system. Built up fascia at R1 roof system where applicable. R7 Canopy Roof - 30 year high profile architectural asphalt shingles (gray/beige) on 30 lbs asphalt impregnated building paper with full covereage Grace ice and water shield secondary underlayment on 15/32" OSB roof deck on framing per structural. XW2 Existing area well wall (field verify existing conditions) LOTS 1 & 2, OBSERVATORY PARK SUBDIVISION