Loading...
HomeMy WebLinkAboutCHRISTIAN BROTHERS AUTOMOTIVE (CBA) REPAIR STORE - PDP - PDP150017 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANS (3)TRACT A 12,737 SQ.FT. 0.292 ACRES FOSSIL CREEK PARKWAY LOT 1 LOT 2 TRACT A TRACT A SNEAD DRIVE Scale 1" = 20' 0' 10' 20' 40' LANDSCAPE CALCULATIONS TOTAL FRONTAGE - COLLEGE AVE.: 117 LF STREET TREES REQUIRED: 3-4 TREES (30'-40' O.C.) STREET TREES PROVIDED: 3 TREES TOTAL FRONTAGE - FOSSIL CREEK PKWY.: 452 LF STREET TREES REQUIRED: 12-15 TREES (30'-40' O.C.) STREET TREES PROVIDED: 12 TREES TOTAL FRONTAGE - SNEAD DR.: 376 LF STREET TREES REQUIRED: 10-13 TREES (30'-40' O.C.) STREET TREES PROVIDED: 10 TREES PARKING LOT PERIMETER TREES REQUIRED - SNEAD DR.: 4 TREES (25' O.C., 90 LF) TREES PROVIDED: 4 TREES PARKING LOT INTERIOR PARKING LOT AREA: 16,445 SF LANDSCAPE AREA REQUIRED: 987 SF (6%) LANDSCAPE AREA PROVIDED: 1,094 SF (6.7%) TREES REQUIRED: 8 TREES (1 PER 150 SF OF LANDSCAPE AREA) TREES PROVIDED: 8 TREES (INCLUDES FOUR EXISTING) THE CONTRACTOR SHALL INSTALL ROOT BARRIERS NEAR ALL NEWLY-PLANTED TREES THAT ARE LOCATED WITHIN FIVE (5) FEET OF PAVING OR CURBS. ROOT BARRIERS SHALL BE "CENTURY" OR "DEEP-ROOT" 24" DEEP PANELS (OR EQUAL). BARRIERS SHALL BE LOCATED IMMEDIATELY ADJACENT TO HARDSCAPE. INSTALL PANELS PER MANUFACTURER'S RECOMMENDATIONS. UNDER NO CIRCUMSTANCES SHALL THE CONTRACTOR USE ROOT BARRIERS OF A TYPE THAT COMPLETELY ENCIRCLE THE ROOTBALL. ROOT BARRIERS AFTER ALL PLANTING IS COMPLETE, CONTRACTOR SHALL INSTALL 4" THICK LAYER OF 1"-2" CRUSHED GRAVEL MULCH (COLOR TO MATCH BUILDING) OVER LANDSCAPE FABRIC IN ALL PLANTING AREAS. CONTRACTOR SHALL SUBMIT SAMPLES OF ALL MULCHES TO LANDSCAPE ARCHITECT AND OWNER FOR APPROVAL PRIOR TO CONSTRUCTION. ABSOLUTELY NO EXPOSED GROUND SHALL BE LEFT SHOWING ANYWHERE ON THE PROJECT AFTER MULCH HAS BEEN INSTALLED. MULCHES E 17725 N Katy Freeway, G Suite I 103 N Houston, E TX E 77094 R Phone: I 281.N 506.7119 G Firm TBPE Registration No. F-12959 www.dacengineers.com LP1 L A W R A N C E PLANTING SPECIFICATIONS HEDGE PLANTING AT PARKING AREA E SCALE: NOT TO SCALE DISTANCE PER PLAN 24" MIN. TO EDGE OF MATURE CANOPY 1 2 3 4 1 CURB. 2 MULCH LAYER. 3 PLANT. 4 TURF (WHERE SHOWN ON PLAN). STEEL EDGING D SCALE: NOT TO SCALE 1 ROLLED-TOP STEEL EDGING PER PLANS. 2 TAPERED STEEL STAKES. 3 MULCH, TYPE AND DEPTH PER PLANS. NOTES: 1) INSTALL EDGING SO THAT STAKES WILL BE ON INSIDE OF PLANTING BED. 2) BOTTOM OF EDGING SHALL BE BURIED A MINIMUM OF 1" BELOW FINISH GRADE. 3) TOP OF MULCH SHALL BE 1" LOWER THAN TOP OF EDGING. 1 2 3 4 4 FINISH GRADE. PLANT CENTER (TYP.) EQUAL NOTE: ALL PLANTS SHALL BE PLANTED AT EQUAL TRIANGULAR SPACING (EXCEPT WHERE SHOWN ON PLANS AS INFORMAL GROUPINGS). REFER TO PLANT LEGEND FOR SPACING DISTANCE BETWEEN PLANTS. AREA DIVIDER PLANT SPACING TO DETERMINE NO. OF PLANTS 6" 0.25 8" 0.45 10" 0.69 12" 1 15" 1.56 18" 2.25 24" 4 30" 6.25 36" 9 EXAMPLE: PLANTS AT 18" O.C. IN 100 SF OF PLANTING AREA = 100/2.25 = 44 PLANTS EQUAL EQUAL EDGE OF PLANTING AREA EQUAL PLANT SPACING C SCALE: NTS 4 X 2X 3 2 1 5 6 7 4 1 2 TRACT A 12,737 SQ.FT. 0.292 ACRES FOSSIL CREEK PARKWAY LOT 1 LOT 2 TRACT A TRACT A SNEAD DRIVE QC F QC QC QC QC QC QC A21 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A18 A17 A20 A19 A1 F F WS A16 Scale 1" = 20' 0' 10' 20' 40' E 17725 N Katy Freeway, G Suite I 103 N Houston, E TX E 77094 R Phone: I 281.N 506.7119 G Firm TBPE Registration No. F-12959 www.dacengineers.com LI1 L A W R A N C E M . L E S S E R 1 8 8 E 17725 N Katy Freeway, G Suite I 103 N Houston, E TX E 77094 R Phone: I 281.N 506.7119 G Firm TBPE Registration No. F-12959 www.dacengineers.com LI2 L A W R A N C E M . L E S S E R 1 8 8 (800) 680-6630 1780 Heritage Center Dr., Suite 104 Wake Forest, NC 27587 www.landscape-consultants.net D E S I G N G R O U P Celebrating 10 Years CITY APPROVALS CONTRACTOR TO CONTACT THE UTILITY NOTIFICATION CENTER OF COLORADO AT 1-800-922-1987 OR 811 AT LEAST THREE DAYS BEFORE DIGGING TO LOCATE ALL UNDERGROUND UTILITIES. BENCHMARKS FLOODPLAIN PROPOSED CHRISTIAN BROTHERS AUTOMOTIVE 1.857 ACRES IN LOT 1, TRACT A OF THE SOUTHWEST QUARTER OF SECTION 1, TOWNSHIP 6 NORTH FORT COLLINS, CO IRRIGATION SPECIFICATIONS AND DETAILS IRRIGATION DISCLAIMER THIS DESIGN IS DIAGRAMMATIC. ALL PIPING, VALVES, AND OTHER EQUIPMENT SHOWN WITHIN PAVED AREAS OR OUT OF PROPERTY BOUNDARIES ARE FOR DESIGN CLARIFICATION ONLY, AND SHALL BE INSTALLED IN PLANTING AREAS WITHIN THE PROPERTY LINES OR LIMITS INDICATED ON PLAN. THE IRRIGATION CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL ABOVE-GRADE IRRIGATION EQUIPMENT WITH THE OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO INSTALLATION, OR IRRIGATION CONTRACTOR MAY BE REQURED TO MOVE SUCH ITEMS AT HIS OWN COST. IRRIGATION CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL FINAL QUANTITIES PER DRAWINGS AND SPECIFICATIONS. ANY QUANTITIES PROVIDED ARE PROVIDED AS A CONVENIENCE TO THE CONTRACTOR ONLY AND SHALL NOT BE CONSIDERED ABSOLUTE. RAINBIRD PEB SERIES REMOTE CONTROL VALVE, SIZE PER PLAN DETAIL E/LI3 F VALVES DETAIL K/LI3 DETAILS I, J/LI3 DRIP CONTROL ZONE KIT (FLOWS UP TO 20 GPM) E 17725 N Katy Freeway, G Suite I 103 N Houston, E TX E 77094 R Phone: I 281.N 506.7119 G Firm TBPE Registration No. F-12959 www.dacengineers.com LI3 L A W R A N C E M . L E S S E R 1 8 8 (800) 680-6630 1780 Heritage Center Dr., Suite 104 Wake Forest, NC 27587 www.landscape-consultants.net D E S I G N G R O U P Celebrating 10 Years CITY APPROVALS CONTRACTOR TO CONTACT THE UTILITY NOTIFICATION CENTER OF COLORADO AT 1-800-922-1987 OR 811 AT LEAST THREE DAYS BEFORE DIGGING TO LOCATE ALL UNDERGROUND UTILITIES. BENCHMARKS FLOODPLAIN PROPOSED CHRISTIAN BROTHERS AUTOMOTIVE 1.857 ACRES IN LOT 1, TRACT A OF THE SOUTHWEST QUARTER OF SECTION 1, TOWNSHIP 6 NORTH FORT COLLINS, CO IRRIGATION DETAILS 2 3 4 7 5 8 12 13 9 10 11 FINISHED GRADE-1" BELOW TOP OF BOX IN TURF AREAS, 2" IN SHRUB AREAS QUICK-COUPLING VALVE 10" ROUND PLASTIC VALVE BOX BY CARSON (OR EQUAL) 6" LONG BRASS NIPPLE BRASS NIPPLE (LENGTH AS REQUIRED) BRICK (1 OF 2) PVC SCH 40 STREET ELL PVC SCH 40 TEE OR ELL PVC MAINLINE PIPE PVC SCH 40 ELL 2" x 2" REDWOOD STAKE WITH STAINLESS STEEL GEAR CLAMPS OR EQUIVALENT SUPPORT SYSTEM 1 TOP OF MULCH 6 3-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL 1 2 3 4 5 7 6 8 9 12 10 9 11 13 QUICK COUPLER F SCALE: NTS 1 2 4 5 3 6 7 9 8 10 11 12 13 14 15 PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) PVC SCH 40 ELL PVC SCH 80 NIPPLE (CLOSE) FINISHED GRADE-1" BELOW TOP OF BOX IN TURF AREAS, 2" IN SHRUB AREAS JUMBO PLASTIC VALVE BOX BY CARSON (OR EQUAL) REMOTE CONTROL VALVE WATERPROOF CONNECTION (ANY APPROVED) 30-INCH LINEAR LENGTH OF WIRE, COILED BRICK (1 OF 4) PVC MAINLINE PIPE PVC SCH 40 TEE OR ELL PVC SCH 40 MALE ADAPTER PVC LATERAL PIPE 3-INCH MINIMUM DEPTH OF 3 4-INCH WASHED GRAVEL 3 4 6 7 8 5 9 10 11 16 15 14 13 MAINLINE DEPTH 12" MIN. TOP OF MULCH 12 16 SCH. 40 PVC ELL 1 2 REMOTE CONTROL VALVE E SCALE: NTS 1 2 4 5 3 6 7 9 8 10 11 12 13 14 15 16 1 2 3 4 5 6 11 9 8 12 10 7 15 14 13 16 DRIP CONTROL ZONE KIT D SCALE: NTS MAINLINE DEPTH 12" MIN. 30-INCH LINEAR LENGTH OF WIRE, COILED WATERPROOF CONNECTION (ANY APPROVED) REMOTE CONTROL VALVE ASSEMBLY JUMBO PLASTIC VALVE BOX BY CARSON (OR EQUAL) TOP OF MULCH FINISHED GRADE-1" BELOW TOP OF BOX IN TURF AREAS, 2" IN SHRUB AREAS PVC UNION (2) PVC SCH 40 MALE ADAPTER (2) PVC LATERAL PIPE BRICK (1 OF 4) 3-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL PVC MAINLINE PIPE PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) SCH. 40 PVC ELL SCH. 40 PVC TEE OR ELL SCH. 40 PVC THREADED ELL 5 7 6 1 4 3 2 FINISH GRADE POP-UP SPRAY HEAD SCH. 80 PVC NIPPLE (LENGTH AS REQUIRED) SCH. 40 PVC ELL SCH. 40 PVC STREET ELL SCH. 40 PVC TEE OR ELL PVC LATERAL PIPE 1 4 5 3 6 5 7 2 12" MIN. POP-UP SPRAY HEAD L SCALE: NTS 3' COILED LENGTH OF LINE SIZE FLEX HOSE. SOLVENT WELD TO VALVE 10" ROUND PLASTIC VALVE BOX WITH LOCKABLE LID, "CARSON" OR APPROVED EQUAL FINISH GRADE - TOP OF VALVE BOX TO BE 2" ABOVE FINISH GRADE IN PLANTER AREAS DRIP EXHAUST HEADER BALL VALVE, LINE SIZE RED BRICK TYPICAL, 3 REQUIRED 6" DEEP LAYER OF PEA GRAVEL 1 2 3 4 5 6 7 1 2 4 5 6 7 3 FLUSH VALVE K SCALE: NTS TOP OF MULCH FINISH GRADE DRIP LINE PER PLAN INSERT TEE OR ELBOW SCH. 80 PVC NIPPLE (LINE SIZE) SCH. 40 PVC TEE (SST) SCH. 40 PVC SUPPLY HEADER (SIZE PER PLAN) 1 2 3 5 6 7 1 2 3 4 5 6 7 4 SUBSURFACE DRIPLINE CONNECTION J SCALE: NOT TO SCALE LATERAL LINE DEPTH 2" MAX. FLUSH VALVE SCH. 40 PVC EXHAUST HEADER SCH. 40 PVC TEE OR ELL COMPRESSION ADAPTER DRIP LINE AIR RELIEF VALVE AT HIGH POINT OF SYSTEM (WHERE INDICATED ON PLANS) SCH. 40 PVC SUPPLY HEADER CONTROL VALVE NOTE: SET DRIP LINES 3"-6" AWAY FROM HARDSCAPE 1 2 3 4 5 6 7 8 3 2 4 5 1 5 6 7 8 4 3 5 2 SUBSURFACE DRIP LINE LAYOUT I SCALE: NOT TO SCALE 8 10 5 6 2 9 7 4 3 1 PAVEMENT SURFACE TRENCH BACKFILL SCH. 40 PVC MAINLINE SLEEVE - SEE PLANS FOR SIZE SCH. 40 PVC LATERAL SLEEVE - SEE PLANS FOR SIZE LOCATOR WIRE W/BURIED CAUTION TAPE PVC IRRIGATION MAINLINE SLEEVING TRENCHING 2 3 5 10 11 1 3 4 6 9 8 7 FINISH GRADE PVC IRRIGATION LATERAL - BURIED MIN. 12" BELOW GRADE SAND BACKFILL SCH. 40 PVC WIRE SLEEVE FOR CONTROL WIRES, MIN. 2" DIA. 11 CONTROL WIRES - TAPE TO MAINLINE AT 10' INTERVALS 18" MIN. 24" MIN. 12" MIN. 18" MIN. PIPE AND SLEEVE INSTALLATION H SCALE: NTS 1 18" MIN. 24" MIN. 2 24" MAX 18" MIN. 24" MAX 9 8 7 12 PVC CAP, SOLVENT WELDED 6 5 2 4 3 PVC MALE ADAPTER BRASS BALL VALVE (SIZED PER MAINLINE) EXTENSION SECTION AS NECESSARY TO MEET GRADE 9" ROUND VALVE BOX WITH LOCKABLE LID 1 2 3 7 6 5 4 1 7MAINLINE IRRIGATION FINISH GRADE AT 1" BELOW TOP OF BOX IN TURF AREAS: 2" BELOW TOP OF BOX IN SHRUB/GROUNDCOVER AREAS 3-INCH MINIMUM DEPTH OF 3 4-INCH WASHED GRAVEL MAINLINE DEPTH BRASS BALL VALVE G SCALE: NTS DETAIL H/LI3 DETAIL H/LI3 DETAIL H/LI3 DETAIL G/LI3 DETAIL F/LI3 DETAIL D/LI3 DETAIL C1/LI2 DETAIL B/LI2 PRESSURIZED PVC MAIN LINE, SCH. 40, 1-1/4" MODEL 825YA - 1" ESP12LXME 12-STATION CONTROLLER, INTERIOR WALL MOUNT, WITH ONE ESPLXMSM12 MODULE, PLUS ETC-LX "ET MANAGER" CARTRIDGE RAIN/FREEZE SENSOR - MOUNT SENSOR ON EAVE OR PARAPET PER MANUFACTURER 1" WATER METER ANY APPROVED CONTROL WIRING SLEEVE, SCH. 40 PVC, 2" BACKFLOW PREVENTER WITH 650A Y-STRAINER AND WILKINS MODEL 500 PRESSURE REGULATOR SET TO 70 PSI. MOUNT IN STRONGBOX INSULATED ENCLOSURE, MODEL #SBBC-60ALHPI. - - - FLUSH VALVE - BALL VALVE IN VALVE BOX WITH 3' LENGTH OF TUBING DETAIL C/LI2 ANY APPROVED ANY APPROVED ANY APPROVED ANY APPROVED RAINBIRD33DLRC QUICK COUPLER, 3/4" - - - - - - QC NIBCO600A T-FP-BALL VALVE, BRASS, FULL-PORT, LINE SIZE RAINBIRD RAINBIRD WR2-RFC NON-PRESSURIZED LATERAL LINE, CL. 200 PVC, SIZE AS NOTED ON PLAN FEBCO IRRIGATION SLEEVE, SCH. 40 PVC, MIN. TWICE SIZE OF PIPE TO BE INSERTED, ONE SLEEVE PER PIPE RAINBIRD XCZ-100-PRB-COM RAINBIRD XFS-06-18 LANDSCAPE DRIP LINE - SPACE LINES AT 18" O.C. 0.6 GPH IRRIGATION LEGEND SYMBOL MANUF. MODEL NO. DESCRIPTION 20 REMARKS/DETAIL DETAIL A/LI2 DRIP IRRIGATION POINT OF CONNECTION MAIN LINE/ LATERALS & SLEEVES CONTROLLERS AND SENSORS VALVE KEY IN ADDITION TO PROVIDING SLEEVES FOR ALL PIPING UNDER ROADWAYS AND WALKWAYS, THE IRRIGATION CONTRACTOR SHALL PROVIDE AND INSTALL SCH. 40 PVC SLEEVES FOR ALL CONTROLLER WIRES OCCURRING UNDER ALL ROADWAYS AND WALKWAYS. SLEEVES FOR CONTROLLER WIRES SHALL BE 2" DIA. AND CONTAIN NO MORE THAN 25 WIRES. CONTROLLER STATION NUMBER GALLONS PER MINUTE VALVE SIZE SLEEVING / WIRING NOTES: DETAIL H/LI3 WS RAINBIRD 1806 POP UP SPRAY NOTES: 1) CONTRACTOR SHALL USE PC SCREENS ON FIXED SPRAY HEADS AS NEEDED TO ACHIEVE APPROPRIATE RADII. ROTORS & SPRAY HEADS RAINBIRD POP UP SPRAY NOZZLE RADIUS G.P.M. P.S.I. 1806 8H 8' 0.52 30 DETAIL L/LI3 HE-10'VAN-10 (Q) 0.45 30 DETAIL L/LI3 RAINBIRD 500430' POP UP ROTOR MPR-30F 5.08 35 RAINBIRD 500435' POP UP ROTOR MPR-35Q 1.67 35 RAINBIRD 500435' POP UP ROTOR MPR-35H 3.33 35 RAINBIRD 500435' POP UP ROTOR MPR-35F 6.62 35 RAINBIRD 500430' POP UP ROTOR MPR-30Q 1.23 35 RAINBIRD 500430' POP UP ROTOR MPR-30H 1.59 35 RAINBIRD 500425' POP UP ROTOR MPR-25F 3.34 35 RAINBIRD 500425' POP UP ROTOR MPR-25Q 0.88 35 RAINBIRD 500425' POP UP ROTOR MPR-25H 1.73 35 DETAIL L/LI3 DETAIL L/LI3 DETAIL L/LI3 DETAIL L/LI3 DETAIL L/LI3 DETAIL L/LI3 DETAIL L/LI3 DETAIL L/LI3 DETAIL L/LI3 IRRIGATION SPECIFICATIONS GENERAL A. QUALIFICATIONS OF IRRIGATION CONTRACTOR 1. ALL WORK SHOWN ON THESE PLANS SHALL BE PERFORMED BY A SINGLE IRRIGATION CONTRACTING FIRM SPECIALIZING IN IRRIGATION SYSTEMS. SEE THE IRRIGATION PLAN FOR SPECIFIC EQUIPMENT AND SYSTEM LAYOUT. 2. THE IRRIGATION CONTRACTOR MUST HAVE ON ITS STAFF A TEXAS LICENSED IRRIGATOR, AS REGULATED BY THE TEXAS COMMISSION ON ENVIRONMENTAL QUALITY. A LICENSED IRRIGATOR OR LICENSED IRRIGATION INSTALLER SHALL BE PRESENT AT THE PROJECT SITE AT ALL TIMES AS WORK IS IN PROGRESS. THE OWNER MAY DEMAND THAT WORK STOP UNTIL THE CONTRACTOR PROVIDES FOR A LICENSED IRRIGATOR OR LICENSED IRRIGATION INSTALLER TO BE PRESENT AT THE PROJECT SITE AND SUPERVISING ALL IRRIGATION WORK. 3. A LIST OF SUCCESSFULLY COMPLETED PROJECTS OF THIS TYPE, SIZE AND NATURE MAY BE REQUESTED BY THE OWNER FOR FURTHER QUALIFICATION MEASURES. B. SCOPE OF WORK 1. WORK COVERED BY THESE SECTIONS INCLUDES THE FURNISHING AND PAYMENT OF ALL MATERIALS, LABOR, SERVICES, EQUIPMENT, LICENSES, TAXES AND ANY OTHER ITEMS THAT ARE NECESSARY FOR THE EXECUTION, INSTALLATION AND COMPLETION OF ALL WORK, SPECIFIED HEREIN AND / OR SHOWN ON THE IRRIGATION PLANS, NOTES, AND DETAILS. 2. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE LAWS, CODES AND REGULATIONS REQUIRED BY AUTHORITIES HAVING JURISDICTION OVER SUCH WORK, INCLUDING ALL INSPECTIONS AND PERMITS REQUIRED BY FEDERAL, STATE AND LOCAL AUTHORITIES IN SUPPLY, TRANSPORTATION AND INSTALLATION OF MATERIALS. 3. THE INTENT OF THE IRRIGATION SYSTEM IS TO PROVIDE 100% COVERAGE OF ALL LANDSCAPE AREAS. THE IRRIGATION PLAN IS GENERALLY DIAGRAMMATIC; COORDINATE IRRIGATION INSTALLATION WITH UTILITY INSTALLATIONS. ACTUAL LOCATION OF CONTROLLER, BACKFLOW DEVICE, PIPING, VALVES, SPRAY HEADS, DRIP IRRIGATION, AND RELATED EQUIPMENT MAY NEED TO BE ADJUSTED BASED ON ACTUAL SITE CONDITIONS. 4. THE IRRIGATION DESIGN IS DIAGRAMMATIC. ALL PIPING, VALVES, AND OTHER EQUIPMENT SHOWN WITHIN PAVED AREAS OR OUT OF PROPERTY BOUNDARIES ARE FOR DESIGN CLARIFICATION ONLY, AND SHALL BE INSTALLED IN PLANTING AREAS WITHIN THE PROPERTY LINES OR LIMITS INDICATED ON THE PLAN. THE IRRIGATION CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL ABOVE-GRADE IRRIGATION EQUIPMENT WITH THE OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO INSTALLATION, OR IRRIGATION CONTRACTOR MAY BE REQURED TO MOVE SUCH ITEMS AT HIS OWN COST. 5. FOR CLARITY PURPOSES, SOME IRRIGATION LINES AND EQUIPMENT ARE SHOWN IN HARDSCAPE AREAS WITHOUT ACCESS SLEEVES; THESE LINES SHALL BE INSTALLED IN A COMMON TRENCH OR AT THE BACK OF CURB IN LANDSCAPE AREAS. MINOR FIELD ADJUSTMENTS SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER. PRODUCTS A. ALL MATERIALS SHALL BE NEW AND WITHOUT FLAWS OR DEFECTS OF ANY TYPE AND SHALL BE THE BEST OF THEIR CLASS AND KIND. ALL MATERIALS SHALL HAVE A MINIMUM GUARANTEE OF ONE YEAR AGAINST MATERIAL DEFECTS OR DEFECTIVE WORKMANSHIP. ALL MATERIALS SHALL BE OF THE BRANDS AND TYPES NOTED ON THE DRAWINGS OR AS SPECIFIED HEREIN, OR APPROVED EQUAL. THE CONTRACTOR MUST FIRST OBTAIN APPROVAL FROM THE IRRIGATION DESIGNER FOR AN 'APPROVED EQUAL' BEFORE INSTALLING SUCH MATERIALS IN THE FIELD, OR THE CONTRACTOR MAY BE REQUIRED TO REPLACE SUCH MATERIALS AT HIS OWN COST. B. BACKFLOW PREVENTION DEVICES SHALL BE OF THE SIZE AND TYPE INDICATED ON THE DRAWINGS. INSTALL BACKFLOW PREVENTION UNITS IN ACCORDANCE WITH IRRIGATION CONSTRUCTION DETAILS AND ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCES. C. PIPING 1. PRESSURE SUPPLY LINES, DOWNSTREAM OF THE POINT-OF-CONNECTION: a. SCHEDULE 40 PVC FOR ALL PIPE 1-1/2" OR LESS b. CLASS 315 PVC FOR ALL PIPE 2" TO 2-1/2" c. CLASS 200 PVC, GASKETED, FOR ALL PIPE 3" AND LARGER 2. SLEEVING AND NON-PRESSURE LATERAL LINES (DOWNSTREAM FROM VALVES): CLASS 200 PVC 3. FITTINGS: SCH. 40 PVC, EXCEPT AS NOTED OTHERWISE. D. VALVES AND DRIP VALVE ASSEMBLIES: TYPE AND SIZE AS NOTED ON PLANS. EACH VALVE SHALL BEAR A PRE-MANUFACTURED, NUMBERED WATERPROOF TAG BEARING A NUMBER CORRESPONDING TO ITS VALVE SEQUENCE OF OPERATION ON THE CONTROLLER. THE OPERATION SEQUENCE SHALL MATCH THAT AS SHOWN ON THE PLANS. E. QUICK COUPLERS, BALL VALVES, AND GATE VALVES: TYPE AND SIZE PER PLANS. F. VALVE BOXES: TYPE AND SIZE AS NOTED ON DETAILS. ALL VALVES BOXES SHALL BE LOCKING BOLT-DOWN TYPE, FURNISHED WITH LIDS AND BOLTS. BOXES SHALL BE OF A SIZE TO CONTAIN THE ENTIRE VALVE AND/OR VALVE ASSEMBLY. THE VALVE BOX LID SHALL HAVE THE VALVE STATION NUMBER HEAT-BRANDED INTO THE LID WITH 2" HIGH LETTERS. G. FIXED SPRAY HEADS AND ROTORS: PLASTIC BODY POP-UP, WITH A REMOVABLE PLASTIC SPRAY NOZZLE. EXACT TYPE, MODEL, AND NOZZLE SHALL BE AS INDICATED ON PLANS. H. INTEGRAL EMITTER DRIP TUBING: TUBING MODEL AND FLOW RATE AS NOTED ON PLANS, WITH INTEGRAL EMITTERS WELDED TO THE INSIDE WALL OF THE TUBING AS AN INTEGRAL PART OF THE TUBING ASSEMBLY. I. AUTOMATIC CONTROLLER: TYPE AND MODEL PER PLANS. PROVIDE VANDAL-PROOF ENCLOSURE FOR ALL EXTERIOR INSTALLATIONS. PROVIDE LINE-VOLTAGE DISCONNECT SWITCH WITH GROUND FAULT PROTECTION. J. 24 VOLT VALVE WIRE SHALL BE A MINIMUM OF #14 GAUGE, U.F. APPROVED FOR DIRECT BURIAL, SINGLE CONDUCTOR IRRIGATION WIRE. EACH CONTROLLER SHALL HAVE A DIFFERENT COLOR STATION AND COMMON WIRE. 1. STATION WIRE - ANY COLOR EXCEPT WHITE OR BLUE 2. COMMON WIRE - WHITE 3. EXTRA COMMON WIRES - BLUE K. WIRE SPLICES SHALL BE ENCASED IN A WATERPROOF COMPOUND OR GEL. ALL FIELD SPLICES SHALL BE LOCATED IN A 6 INCH ROUND VALVE BOX. L. RAIN SENSOR: TYPE AND MODEL PER PLANS. METHODS A. THIS DESIGN IS DIAGRAMMATIC. ALL PIPING, VALVES, AND OTHER EQUIPMENT SHOWN WITHIN PAVED AREAS OR OUT OF PROPERTY BOUNDARIES ARE FOR DESIGN CLARIFICATION ONLY, AND SHALL BE INSTALLED IN PLANTING AREAS WITHIN THE PROPERTY LINES OR LIMITS INDICATED ON PLAN. THE IRRIGATION CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL ABOVE-GRADE IRRIGATION EQUIPMENT WITH THE OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO INSTALLATION, OR IRRIGATION CONTRACTOR MAY BE REQURED TO MOVE SUCH ITEMS AT HIS OWN COST. ENSURE FIELD COORDINATION IS MADE EARLY ON IN THE CONSTRUCTION PHASE SO PLACEMENT LOCATION IS CORRECT. B. THE IRRIGATION CONTRACTOR SHALL MEET WITH THE OWNER'S REPRESENTATIVE PRIOR TO COMMENCEMENT OF WORK, AND SHALL OBTAIN ALL ENGINEERING, LANDSCAPE, AND OTHER APPLICABLE PLANS & DOCUMENTS. THE CONTRACTOR SHALL THOROUGHLY REVIEW THE PLANS AND REPORT ANY CONFLICTS OR DISCREPANCIES TO THE LANDSCAPE ARCHITECT AND OWNER'S REPRESENTATIVE IMMEDIATELY. C. THE IRRIGATION CONTRACTOR SHALL NOT WILFULLY INSTALL THE IRRIGATION SYSTEM AS SHOWN ON THE DRAWINGS WHEN IT IS OBVIOUS IN THE FIELD THAT UNKNOWN OBSTRUCTIONS, GRADES OR DIMENSIONS EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEEERING. SUCH OBSTRUCTIONS OR DIFFERENCES SHALL BE BROUGHT TO THE ATTENTION OF THE IRRIGATION DESIGNER. IN THE EVENT THAT THIS NOTIFICATION IS NOT PERFORMED, THE IRRIGATION CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY REVISIONS AND NECESSARY COSTS. D. THE IRRIGATION CONTRACTOR SHALL COORDINATE AND PAY FOR THE INSTALLATION OF THE IRRIGATION TAP AND METER. E. THE IRRIGATION CONTRACTOR SHALL PAY ANY AND ALL FEES ASSOCIATED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM. F. AT LEAST SEVEN DAYS BEFORE BEGINNING WORK, CONFIRM THE STATIC WATER PRESSURE IS AT LEAST 70 PSI . IF STATIC WATER PRESSURE IS LESS THAN STATED, DO NOT PROCEED WITHOUT FIRST NOTIFYING THE IRRIGATION DESIGNER AND OWNER IN WRITING, AND OBTAINING SUBSEQUENT DIRECTION FOR CORRECTIONAL MEASURES. SHOULD THE IRRIGATION CONTRACTOR CHOOSE TO BEGIN THE INSTALLATION WITHOUT SUCH NOTIFICATION, THE IRRIGATION CONTRACTOR WILL ASSUME THE RESPONSIBILITY FOR ALL COSTS INCURRED TO ENSURE THE SYSTEM IS WORKING PROPERLY. NO CHANGE ORDERS WILL BE AUTHORIZED IN SUCH CIRCUMSTANCES. G. THE IRRIGATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND UTILITY LINES (WATER, SEWER, ELECTRICAL, TELEPHONE, GAS, CABLE, TELEVISION, ETC.) PRIOR TO THE START OF ANY WORK. THE CONTRACTOR SHALL BE FAMILIAR WITH ALL GRADE DIFFERENCES, LOCATIONS OF WALLS, STRUCTURES AND UTILITIES. H. COORDINATE WITH THE OWNER THE PROPOSED LOCATIONS OF THE AUTOMATIC CONTROLLER AND ANY REQUIRED SLEEVES THROUGH THE BUILDING FOR CONTROL WIRES. I. TRENCHING NEAR EXISTING TREES: 1. CONTRACTOR SHALL NOT DISTURB ROOTS 1-1/2" AND LARGER IN DIAMETER WITHIN THE CRITICAL ROOT ZONE (CRZ) OF EXISTING TREES, AND SHALL EXERCISE ALL POSSIBLE CARE AND PRECAUTIONS TO AVOID INJURY TO TREE ROOTS, TRUNKS, AND BRANCHES. THE CRZ IS DEFINED AS A CIRCULAR AREA EXTENDING OUTWARD FROM THE TREE TRUNK, WITH A RADIUS EQUAL TO 1' FOR EVERY 1" OF TRUNK DIAMETER-AT-BREAST-HEIGHT (4.5' ABOVE THE AVERAGE GRADE AT THE TRUNK). 2. ALL EXCAVATION WITHIN THE CRZ SHALL BE PERFORMED USING HAND TOOLS. NO MACHINE EXCAVATION OR TRENCHING OF ANY KIND SHALL BE ALLOWED WITHIN THE CRZ. 3. ALTER ALIGNMENT OF PIPE TO AVOID TREE ROOTS 1-1/2" AND LARGER IN DIAMETER. WHERE TREE ROOTS 1-1/2" AND LARGER IN DIAMETER ARE ENCOUNTERED IN THE FIELD, TUNNEL UNDER SUCH ROOTS. WRAP EXPOSED ROOTS WITH SEVERAL LAYERS OF BURLAP AND KEEP MOIST. CLOSE ALL TRENCHES WITHIN THE CANOPY DRIP LINES WITHIN 24 HOURS. 4. ALL SEVERED ROOTS SHALL BE HAND PRUNED WITH SHARP TOOLS AND ALLOWED TO AIR-DRY. DO NOT USE ANY SORT OF SEALERS OR WOUND PAINTS. J. ALL BACKFILL MATERIAL SHALL BE SUBJECT TO APPROVAL BY THE OWNER. BACKFILL MATERIAL SHALL BE FREE FROM RUBBISH, ROCK, LARGE STONES, BRUSH, SOD, FROZEN MATERIAL OR OTHER UNSUITABLE SUBSTANCES THAT MAY DAMAGE PIPE DURING THE BACKFILLING OPERATIONS. IN THE EVENT THAT THE MATERIAL FROM THE EXCAVATION OR TRENCHING IS FOUND TO BE UNSUITABLE FOR USE IN BACKFILL, IT SHALL BE REMOVED FROM THE SITE AND PROPERLY AND LEGALLY DISPOSED OF BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. THE CONTRACTOR SHALL THEN PURCHASE AND AND FURNISH SUITABLE BACKFILL MATERIAL CONSISTING OF EARTH, LOAM, SANDY CLAY, SAND OR OTHER APPROVED MATERIALS FREE OF DEBRIS. K. BACKFLOW INSTALLATION: CONTRACTOR SHALL MAKE CONNECTIONS TO EXISTING WATER SOURCES AT LOCATION SHOWN ON PLANS AND AS APPROVED BY THE OWNER, AND SHALL MAKE ANY MINOR CHANGES IN LOCATION AS MAY BE NECESSARY DUE TO ACTUAL SITE CONDITIONS. BACKFLOW HEIGHT SHALL BE AS PER LOCAL CODES AND IRRIGATION DETAILS. INSTALL A BRASS BALL VALVE IMMEDIATELY UPSTREAM OF THE BACKFLOW DEVICE TO SERVE AS AN ISOLATION VALVE. L. PIPING: 1. PIPE SIZE SHALL CONFORM TO THOSE SHOWN ON THE DRAWINGS. NO SUBSTITUTIONS OF SMALLER PIPE SIZES SHALL BE PERMITTED, BUT SUBSTITUTIONS FOR LARGER SIZES MAY BE APPROVED. 2. MAINLINE PIPE AND WIRES SHALL BE INSTALLED WITH A MINIMUM COVER OF 24 INCHES. LATERAL PIPE SHALL BE INSTALLED WITH A MINIMUM COVER OF 18 INCHES. 3. ASSEMBLE ALL THREADED FITTINGS WITH TEFLON TAPE, WHICH SHALL BE APPLIED TO MALE THREADS ONLY. 4. ALL SOLVENT-WELD CONNECTIONS SHALL BE MADE WITH APPROVED SOLVENT-WELD PRIMER AND GLUE. 5. PIPE SHALL BE INSTALLED WITH A MINIMUM OF 4" HORIZONTAL CLEARANCE FROM ANY OTHER PIPE AND 2" VERTICAL CLEARANCE FROM ANY PIPES THAT CROSS OVER OR UNDER. M. VALVES SHALL BE INSTALLED PER MANUFACTURER'S DIRECTIONS AND THE IRRIGATION DETAILS. EACH VALVE SHALL BEAR A PRE-PRINTED WATERPROOF TAG BEARING THE APPROPRIATE CONTROLLER STATION NUMBER. N. VALVE BOXES SHALL BE INSTALLED FLUSH WITH THE GRADE, WITH CLEAN PEA GRAVEL LOCATED BELOW THE VALVE AS NOTED ON THE DETAILS. EACH VALVE BOX COVER SHALL BE HEAT-BRANDED WITH THE CONTROLLER STATION NUMBER. O. DRIP IRRIGATION EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S DIRECTIONS AND THE IRRIGATION DETAILS. 1. SUBSURFACE DRIP LINES SHALL BE BURIED NO MORE THAN 2" BELOW FINISH GRADE. 2. DRIP LINES MOUNTED ON GRADE SHALL BE LOCATED BENEATH LANDSCAPE FABRIC, AND SECURED IN PLACE WITH WIRE STAPLES AT A MAXIMUM OF 48" ON CENTER. P. SPRAY, ROTOR, AND BUBBLER HEADS: 1. ALL SPRAY AND ROTOR HEAD LOCATIONS SHALL BE STAKED, FLAGGED AND/OR OTHERWISE CLEARLY MARKED ON THE GROUND PRIOR TO INSTALLATION. SPRINKLER HEAD STAKING SHALL BE INSPECTED AND APPROVED BY THE OWNER'S REPRESENTATIVE BEFORE INSTALLATION. 2. ALL SPRAY HEADS SHALL BE CONNECTED WITH A 12 INCH MINIMUM LENGTH OF 1 2 INCH FLEX PVC. THE FLEX PVC SHALL BE SOLVENT WELDED TO SCHEDULE 40 PVC FITTINGS WITH WELD-ON #795 SOLVENT AND #P-70 PRIMER. ALL ROTORS SHALL BE CONNECTED TO LATERAL LINES WITH PRE-MANUFACTURED SWING JOINTS. 3. ALL ROTOR, SPRAY AND BUBBLER HEADS SHALL BE SET PERPENDICULAR AND FLUSH TO FINISH GRADE AND WITH A CLEARANCE OF FOUR INCHES (MINIMUM) FROM THE EDGE OF ANY BUILDINGS, WALLS, BOULDERS, AND HARDSCAPE, UNLESS OTHERWISE SPECIFIED. 4. ALL ROTOR, SPRRAY AND BUBBLER HEADS AND VALVES SHALL BE FLUSHED AND ADJUSTED FOR OPTIMUM COVERAGE WITH MINIMUM OVERSPRAY ON WALKS, STREETS, WALLS, ETC. Q. AUTOMATIC CONTROLLER: 1. INSTALL THE CONTROLLER AT THE LOCATION INDICATED BY THE OWNER. INSTALL CONTROLLER WITH A BACKUP BATTERY AS RECOMMENDED BY THE MANUFACTURER. 2. THE IRRIGATION CONTRACTOR SHALL COORDINATE 120 V.A.C. ELECTRICAL POWER TO CONTROLLER AND DEDICATE ONE (1) 20-AMP BREAKER FOR EACH CONTROLLER. IT SHALL BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO MAKE THE FINAL HOOK-UP FROM THE ELECTRICAL SOURCE TO THE CONTROLLER UNIT ONLY. 3. ALL VALVE CONTROL WIRE SHALL BE AWG 14 TYPE UF, 600 VOLT TEST, DIRECT BURIAL. NO SPLICES SHALL BE ALLOWED EXCEPT AT VALVES AND CONTROLLER. WHERE SPLICES MAY BE NECESSARY DUE TO EXCESSIVELY LONG WIRE RUNS, THE CONTRACTOR SHALL MAKE ALL SPLICES IN 6" ROUND VALVE BOXES WITH 3M'S "DBY-DIRECT BURIAL SPLICE KIT". THE CONTRACTOR SHALL LABEL ALL WIRES WITH WATERPROOF TAGS AND MARKERS AT ALL SPLICES AND VALVE MANIFOLDS, AND SHALL LEAVE A 24" COIL OF EXCESS WIRE AT EACH CONNECTION. 4. PROVIDE #10 COMMON WIRE, DIRECT BURIAL, TO ALL REMOTE CONTROL VALVES. 5. CONNECT ALL DIRECT BURIAL WIRES TO VALVES USING 3M'S "DBY-DIRECT BURIAL SPLICE KIT" (UNLESS OTHERWISE SPECIFIED). 6. PROVIDE THREE ADDITIONAL IRRIGATION CONTROL WIRES ALONG EACH BRANCH OF MAINLINE FOR FUTURE EXPANSION. STUB ADDITIONAL CONTROL WIRES INTO BACK OF IRRIGATION CONTROLLERS. 7. THE IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL CONTROL WIRE SLEEVES AND PIPE SLEEVES UNDER PAVED AREAS PRIOR TO PAVING - SEE SLEEVING NOTES. R. INSTALL THE RAIN SENSOR IN THE VICINITY OF THE CONTROLLER, AND COORDINATE LOCATION WITH THE OWNER. IT IS THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO ENSURE THE RAIN SENSOR IS PLACED IN A LOCATION WHERE IT CAN RECEIVE ADEQUATE RAINFALL WITHOUT OBSTRUCTIONS. IF IT IS PLACED IN AN INADEQUATE LOCATION, THE IRRIGATION CONTRACTOR MAY BE REQUIRED TO RELOCATE IT AT NO ADDITIONAL COST TO THE OWNER. S. ALL IRRIGATION EQUIPMENT NOT OTHERWISE DETAILED OR SPECIFIED SHALL BE INSTALLED AS PER MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS. T. QUALITY CONTROL 1. PERFORM COVERAGE TESTS AFTER SPRINKLER SYSTEM IS COMPLETED, BUT PRIOR TO ANY PLANTING AND PERFORM TESTING IN THE PRESENCE OF THE IRRIGATION DESIGNER AND THE CONSTRUCTION MANAGER. 2. TEST SYSTEM TO ASSURE THAT ALL LAWN AND PLANTING AREAS ARE WATERED COMPLETELY AND UNIFORMLY. 3. MAKE ALL NECESSARY ADJUSTMENTS TO PROVIDE COMPLETE COVERAGE, INCLUDING REALIGNMENT OF HEADS AND REPLACEMENT OF NOZZLES. U. CLEAN UP 1. DURING IRRIGATION EXCAVATION AND INSTALLATION, KEEP ALL PAVEMENT CLEAN AND ALL WORK AREAS IN A NEAT, ORDERLY CONDITION. 2. DISPOSED LEGALLY OF ALL EXCAVATED MATERIALS OFF THE PROJECT SITE. V. INSPECTION AND ACCEPTANCE 1. UPON COMPLETION OF THE WORK, THE IRRIGATION CONTRACTOR SHALL PROVIDE THE SITE CLEAN, FREE OF DEBRIS AND TRASH, AND SUITABLE FOR USE AS INTENDED. THE IRRIGATION CONTRACTOR SHALL THEN REQUEST AN INSPECTION BY THE OWNER TO DETERMINE FINAL ACCEPTABILITY. 3. WHEN THE INSPECTED WORK DOES NOT COMPLY WITH THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL REPLACE AND/OR REPAIR THE REJECTED WORK TO THE OWNER'S SATISFACTION WITHIN 24 HOURS. 4. THE MAINTENANCE PERIOD WILL NOT COMMENCE UNTIL THE WORK HAS BEEN RE-INSPECTED BY THE OWNER AND FOUND TO BE ACCEPTABLE. AT THAT TIME, A WRITTEN NOTICE OF FINAL ACCEPTANCE WILL BE ISSUED BY THE OWNER, AND THE MAINTENANCE AND GUARANTEE PERIODS WILL COMMENCE. 5. CONTROLLER CHART: THE IRRIGATION CONTRACTOR SHALL PROVIDE A 8 1 2" X 11" COLOR-CODED, LAMINATED COPY OF THE IRRIGATION LAYOUT AND PLACE IT IN THE CONTROLLER'S COVER. THE CONTROLLER CHART SHALL CLEARLY DELINEATE THE AREAS COVERED BY EACH VALVE, USING A SEPARATE COLOR FOR EACH ZONE. 6. TURN THE FOLLOWING ITEMS IN TO THE OWNER UPON COMPLETION OF THE INSTALLATION: a. QUICK COUPLER KEYS (2) b. CONTROLLER MANUAL (1) c. CONTROLLER KEYS (2) d. A MINIMUM OF (2) COPIES OF RECORD DRAWINGS. A RECORD DRAWING IS A RECORD OF ALL CHANGES THAT OCCURRED IN THE FIELD AND THAT ARE DOCUMENTED THROUGH CHANGE ORDERS, ADDENDA, OR CONTRACTOR/CONSULTANT DRAWING MARKUPS. W. REFER TO THE PLANTING SPECIFICATIONS FOR ADDITIONAL CONDITIONS OF FINAL ACCEPTANCE AND START OF THE MAINTENANCE PERIOD. X. WARRANTY 1. THE IRRIGATION SYSTEM SUPPLIED AND INSTALLED SHALL BE WARRANTED (LABOR AND MATERIALS) TO REMAIN OPERATIONAL FOR A PERIOD OF 12 MONTHS AFTER THE DATE OF FINAL ACCEPTANCE. DURING THIS PERIOD, THE CONTRACTOR SHALL ALSO REPAIR ANY SETTLEMENT OF THE IRRIGATION TRENCHES. 2. BY THE END OF THE WARRANTY PERIOD, ANY IRRIGATION PART THAT IS EITHER NON-OPERATIONAL OR THAT IS OPERATING BELOW STANDARDS AS DETERMINED BY THE OWNER, SHALL BE REMOVED FROM THE SITE AND SHALL BE REPLACED. REPLACEMENTS SHALL BE OF THE SAME KIND AS SPECIFIED IN THE IRRIGATION LEGEND, AND SHALL BE INSTALLED AS ORIGINALLY SPECIFIED. 3. IRRIGATION PARTS DAMAGED OR IMPAIRED DUE TO ACTS OF GOD, VANDALISM, AND/OR THE OWNER'S IMPROPER MAINTENANCE SHALL NOT BE COVERED BY THIS WARRANTY. BACKFLOW PREVENTER C SCALE: NTS 2 1 1 2 PARAPET OR EAVE AUTOMATIC RAIN SENSOR - INSTALL PER MANUFACTURER'S INSTRUCTIONS RAIN SENSOR, ROOF MOUNT B SCALE: NTS A SCALE: NTS 1 2 3 4 CONTROLLER - WALL MOUNT, INDOOR NOTES: 1) MOUNT CONTROLLER AND CABINET PER MANUFACTURER'S DIRECTIONS. 2) 120 V.A.C. POWER PROVIDED BY OTHERS. LANDSCAPE CONTRACTOR SHALL MAKE FINAL CONNECTION AT CONTROLLER. CONNECT TO ELECTRICAL SUPPLY PER NATIONAL ELECTRIC CODE AND LOCAL CODE. 3) LOCATE GROUND ROD 8' MIN. FROM CONTROLLER. VERIFY LOCATION OF GROUND ROD, CONTROLLER AND SOURCE OF ELECTRICITY WITH MANUFACTURER'S REPRESENTATIVE AND OWNER AS PART OF PRE CONSTRUCTION MEETING. SECTION 3 2 1 5 6 4 7 8 9 11 10 60" MAX. 12" CONTROLLER PER LEGEND 1/2" ELECTRICAL CONDUIT BETWEEN CONTROLLER AND ELECT. BOX CLAMP TO WALL SENSOR MONITOR PANEL OR RECEIVER (WHERE OCCURS) WALL 120 VOLT SERVICE IN WATERPROOF JUNCTION BOX WITH DISCONNECT SWITCH, INSTALL INSIDE STAINLESS ENCLOSURE C-CLAMPS (TYP.) CONDUIT(S) FOR 24 VOLT CONTROL WIRES. CLAMP TO WALL. USE 1 CONDUIT FOR 0-24 STATIONS. USE 2 CONDUITS FOR 25-48 STATIONS SENSOR CABLES IN CONDUITS (WHERE OCCURS) GROUNDING PER MANUFACTURER WALL FINISH FLOOR SURFACE 5 7 6 10 9 8 11 6" 2 12" SUMP DEPTH 12" DIA. GRAVEL FILL SUMP PIT 1 2 NOTE: AUTOMATIC VALVES ARE TO BE LOCATED AT LOW POINTS OF LATERAL LINES. LOCATE END DRAIN VALVE 12" UPSTREAM FROM LAST HEAD. PIPE TRENCH 1 FINISH GRADE 45d TO 30d GAP BELOW HORIZONTAL AUTOMATIC DRAIN VALVE SCALE: NOT TO SCALE 3 3 LATERAL LINE PIPE 4 AUTOMATIC DRAIN VALVE 4 CITY MAINLINE 5 ISOLATION VALVE (PER PLAN) WATER METER SERVICE LINE 2 TAP 3 4 1 8 BACKFLOW DEVICE (WHERE SHOWN) 6 7 BLOW OFF VALVE (BOV) MANUAL DRAIN VALVE (BALL VALVE) WINTERIZATION PROCEDURE: 1. TURN OFF EITHER THE METER AND ISOLATION VALVE (DEDICATED IRRIGATION METER) OR ISOLATION VALVE (DOMESTIC TAP). 2. OPEN ONE CONTROL VALVE TO RELIEVE PRESSURE 3. SLOWLY OPEN MANUAL DRAIN VALVE. 4. REPEAT PROCEDURE FOR ALL MANUAL DRAIN VALVES ALONG IRRIGATION MAINLINE. 5. CLOSE MANUAL DRAIN VALVES AND BLOW OUT REMAINING WATER FROM THE BLOWOUT VALVE. SLOWLY INCREASE AIR PRESSURE, NOT TO EXCEED 80 PSI. DO NOT BLOW OUT SYSTEM FROM BACKFLOW. BLOW OUT SYSTEM TWICE BUT NOT TO EXCEED AT MORE THAN 2 MIN. INTERVALS. WATER TAP DIAGRAM C1 SCALE: NTS QC QC DEDICATED IRRIGATION TAP IRRIGATION CONNECTION FROM DOMESTIC WATER 1 2 3 4 5 6 7 8 TO IRRIGATION SYSTEM TO DOMESTIC SYSTEM TO IRRIGATION SYSTEM 1 2 3 4 6 7 8 5 8" MIN. 6" MIN. TO POINT OF CONNECTION - ADAPT AS NECESSARY. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES BRASS WYE STRAINER W/60 MESH SCREEN ENCLOSURE PER IRRIGATION LEGEND BACKFLOW PREVENTER UNIT BRASS UNION (TYPICAL) PRESSURE REDUCER BRASS NIPPLES (TYPICAL) 4" CONCRETE PAD, SLOPE TO DRAIN AWAY FROM BACKFLOW PREVENTER FINISH GRADE, 2" BELOW PAD BRASS COUPLING PVC ADAPTER AND MAINLINE PIPE 12"X12"X24" THRUST BLOCK 1 2 3 4 5 6 7 8 9 10 11 2 3 4 5 7 8 9 10 11 12 1 12" MIN, 30" MAX (REFER TO LOCAL CODES) 6 12 (800) 680-6630 1780 Heritage Center Dr., Suite 104 Wake Forest, NC 27587 www.landscape-consultants.net D E S I G N G R O U P Celebrating 10 Years CITY APPROVALS CONTRACTOR TO CONTACT THE UTILITY NOTIFICATION CENTER OF COLORADO AT 1-800-922-1987 OR 811 AT LEAST THREE DAYS BEFORE DIGGING TO LOCATE ALL UNDERGROUND UTILITIES. BENCHMARKS FLOODPLAIN PROPOSED CHRISTIAN BROTHERS AUTOMOTIVE 1.857 ACRES IN LOT 1, TRACT A OF THE SOUTHWEST QUARTER OF SECTION 1, TOWNSHIP 6 NORTH FORT COLLINS, CO IRRIGATION PLAN SEE SHEET LI2 FOR IRRIGATION LEGEND POINT OF CONNECTION CONNECT MAINLINE DOWNSTREAM OF 1" WATER METER (BY OTHERS). VERIFY LOCATION IN FIELD. LOCATE CONTROLLER AT LOCATION SHOWN ON PLAN. VERIFY LOCATION IN FIELD WITH OWNER'S REPRESENTATIVE. 120 VAC POWER TO CONTROLLER LOCATION IS NOT WITHIN THE IRRIGATION CONTRACTOR'S SCOPE OF WORK, AND SHALL BE PROVIDED BY OTHERS. HOOK-UP OF CONTROLLER TO 120 VAC SHALL BE PERFORMED BY THE LANDSCAPE CONTRACTOR. IRRIGATION CONTRACTOR SHALL COORDINATE LOCATION OF WIRE SLEEVE PENETRATIONS THROUGH BUILDING WITH OWNER AND GENERAL CONTRACTOR. STATION RUN ORDER SHALL MATCH PLANS. AFTER INSTALLATION OF THE IRRIGATION SYSTEM IS COMPLETE, THE CONTRACTOR SHALL ESTABLISH A "WEATHER REACH" SUBSCRIPTION. CONTRACTOR SHALL INCLUDE THE COST OF THE FIRST YEAR'S SUBSCRIPTION IN HIS BID. CONTROLLER NOTE CONTROLLER - SEE NOTE 3 SHRUB, PERENNIAL, OR ORNAMENTAL GRASS. MULCH, TYPE AND DEPTH PER PLANS. PLACE NO MORE THAN 1" OF MULCH WITHIN 6" OF PLANT CENTER. FINISH GRADE. BACKFILL. AMEND AND FERTILIZE ONLY AS RECOMMENDED IN SOIL FERTILITY ANALYSIS. ROOT BALL. UNDISTURBED NATIVE SOIL. 3" HIGH EARTHEN WATERING BASIN. 5 6 7 SHRUB AND PERENNIAL PLANTING B SCALE: NTS 8 WEED FABRIC UNDER MULCH. 8 GENERAL A. QUALIFICATIONS OF LANDSCAPE CONTRACTOR 1. ALL LANDSCAPE WORK SHOWN ON THESE PLANS SHALL BE PERFORMED BY A SINGLE FIRM SPECIALIZING IN LANDSCAPE PLANTING. 2. A LIST OF SUCCESSFULLY COMPLETED PROJECTS OF THIS TYPE, SIZE AND NATURE MAY BE REQUESTED BY THE OWNER FOR FURTHER QUALIFICATION MEASURES. 3. THE LANDSCAPE CONTRACTOR SHALL HOLD A VALID CONTRACTOR'S LICENSE ISSUED BY THE APPROPRIATE LOCAL JURISDICTION. B. SCOPE OF WORK 1. WORK COVERED BY THESE SECTIONS INCLUDES THE FURNISHING AND PAYMENT OF ALL MATERIALS, LABOR, SERVICES, EQUIPMENT, LICENSES, TAXES AND ANY OTHER ITEMS THAT ARE NECESSARY FOR THE EXECUTION, INSTALLATION AND COMPLETION OF ALL WORK, SPECIFIED HEREIN AND / OR SHOWN ON THE LANDSCAPE PLANS, NOTES, AND DETAILS. 2. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE LAWS, CODES AND REGULATIONS REQUIRED BY AUTHORITIES HAVING JURISDICTION OVER SUCH WORK, INCLUDING ALL INSPECTIONS AND PERMITS REQUIRED BY FEDERAL, STATE AND LOCAL AUTHORITIES IN SUPPLY, TRANSPORTATION AND INSTALLATION OF MATERIALS. 3. THE LANDSCAPE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND UTILITY LINES (WATER, SEWER, ELECTRICAL, TELEPHONE, GAS, CABLE, TELEVISION, ETC.) PRIOR TO THE START OF ANY WORK. PRODUCTS A. ALL MANUFACTURED PRODUCTS SHALL BE NEW. B. CONTAINER AND BALLED-AND-BURLAPPED PLANTS: 1. FURNISH NURSERY-GROWN PLANTS COMPLYING WITH ANSI Z60.1-2004. PROVIDE WELL-SHAPED, FULLY BRANCHED, HEALTHY, VIGOROUS STOCK FREE OF DISEASE, INSECTS, EGGS, LARVAE, AND DEFECTS SUCH AS KNOTS, SUN SCALD, INJURIES, ABRASIONS, AND DISFIGUREMENT. ALL PLANTS WITHIN A SPECIES SHALL HAVE SIMILAR SIZE, AND SHALL BE OF A FORM TYPICAL FOR THE SPECIES. ALL TREES SHALL BE OBTAINED FROM SOURCES WITHIN 200 MILES OF THE PROJECT SITE, AND WITH SIMILAR CLIMACTIC CONDITIONS. 2. ROOT SYSTEMS SHALL BE HEALTHY, DENSELY BRANCHED ROOT SYSTEMS, NON-POT-BOUND, FREE FROM ENCIRCLING AND/OR GIRDLING ROOTS, AND FREE FROM ANY OTHER ROOT DEFECTS (SUCH AS J-SHAPED ROOTS). 3. ANY PLANT DEEMED UNACCEPTABLE BY THE LANDSCAPE ARCHITECT OR OWNER SHALL BE IMMEDIATELY REMOVED FROM THE SITE AND SHALL BE REPLACED WITH AN ACCEPTBLE PLANT OF LIKE TYPE AND SIZE AT THE CONTRACTOR'S OWN EXPENSE. ANY PLANTS APPEARING TO BE UNHEALTHY, EVEN IF DETERMINED TO STILL BE ALIVE, SHALL NOT BE ACCEPTED. THE LANDSCAPE ARCHITECT AND OWNER SHALL BE THE SOLE JUDGES AS TO THE ACCEPTABILITY OF PLANT MATERIAL. 4. ALL TREES SHALL BE STANDARD IN FORM, UNLESS OTHERWISE SPECIFIED. TREES WITH CENTRAL LEADERS WILL NOT BE ACCEPTED IF LEADER IS DAMAGED OR REMOVED. PRUNE ALL DAMAGED TWIGS AFTER PLANTING. 5. CALIPER MEASUREMENTS FOR STANDARD (SINGLE TRUNK) TREES SHALL BE AS FOLLOWS: SIX INCHES ABOVE THE ROOT FLARE FOR TREES UP TO AND INCLUDING FOUR INCHES IN CALIPER, AND TWELVE INCHES ABOVE THE ROOT FLARE FOR TREES EXCEEDING FOUR INCHES IN CALIPER. 6. MULTI-TRUNK TREES SHALL BE MEASURED BY THEIR OVERALL HEIGHT, MEASURED FROM THE TOP OF THE ROOT BALL. 7. ANY TREE OR SHRUB SHOWN TO HAVE EXCESS SOIL PLACED ON TOP OF THE ROOT BALL, SO THAT THE ROOT FLARE HAS BEEN COMPLETELY COVERED, SHALL BE REJECTED. C. SOD: PROVIDE WELL-ROOTED SOD OF THE VARIETY NOTED ON THE PLANS. SOD SHALL BE CUT FROM HEALTHY, MATURE TURF WITH SOIL THICKNESS OF 3/4" TO 1". EACH PALLET OF SOD SHALL BE ACCOMPANIED BY A CERTIFICATE FROM SUPPLIER STATING THE COMPOSITION OF THE SOD. D. SEED: PROVIDE BLEND OF SPECIES AND VARIETIES AS NOTED ON THE PLANS, WITH MAXIMUM PERCENTAGES OF PURITY, GERMINATION, AND MINIMUM PERCENTAGE OF WEED SEED AS INDICATED ON PLANS. EACH BAG OF SEED SHALL BE ACCOMPANIED BY A TAG FROM THE SUPPLIER INDICATING THE COMPOSITION OF THE SEED. E. TOPSOIL: SANDY TO CLAY LOAM TOPSOIL, FREE OF STONES LARGER THAN ½ INCH, FOREIGN MATTER, PLANTS, ROOTS, AND SEEDS. F. COMPOST: WELL-COMPOSTED, STABLE, AND WEED-FREE ORGANIC MATTER, pH RANGE OF 5.5 TO 8; MOISTURE CONTENT 35 TO 55 PERCENT BY WEIGHT; 100 PERCENT PASSING THROUGH 3/4-INCH SIEVE; SOLUBLE SALT CONTENT OF 5 TO 10 DECISIEMENS/M; NOT EXCEEDING 0.5 PERCENT INERT CONTAMINANTS AND FREE OF SUBSTANCES TOXIC TO PLANTINGS. NO MANURE OR ANIMAL-BASED PRODUCTS SHALL BE USED. G. FERTILIZER: GRANULAR FERTILIZER CONSISTING OF NITROGEN, PHOSPHORUS, POTASSIUM, AND OTHER NUTRIENTS IN PROPORTIONS, AMOUNTS, AND RELEASE RATES RECOMMENDED IN A SOIL REPORT FROM A QUALIFIED SOIL-TESTING AGENCY (SEE BELOW). H. MULCH: SIZE AND TYPE AS INDICATED ON PLANS, FREE FROM DELETERIOUS MATERIALS AND SUITABLE AS A TOP DRESSING OF TREES AND SHRUBS. I. WEED FABRIC: 5 OUNCE, WOVEN, NEEDLE-PUNCHED FABRIC, SUCH AS DEWITT PRO5 LANDSCAPE FABRIC (OR APPROVED EQUAL). J. TREE STAKING AND GUYING 1. STAKES: 6' LONG GREEN METAL T-POSTS. 2. GUY AND TIE WIRE: ASTM A 641, CLASS 1, GALVANIZED-STEEL WIRE, 2-STRAND, TWISTED, 0.106 INCH DIAMETER. 3. STRAP CHAFING GUARD: REINFORCED NYLON OR CANVAS AT LEAST 1-1/2 INCH WIDE, WITH GROMMETS TO PROTECT TREE TRUNKS FROM DAMAGE. K. STEEL EDGING: PROFESSIONAL STEEL EDGING, 14 GAUGE THICK X 4 INCHES WIDE, FACTORY PAINTED DARK GREEN. ACCEPTABLE MANUFACTURERS INCLUDE COL-MET OR APPROVED EQUAL. L. PRE-EMERGENT HERBICIDES: ANY GRANULAR, NON-STAINING PRE-EMERGENT HERBICIDE THAT IS LABELED FOR THE SPECIFIC ORNAMENTALS OR TURF ON WHICH IT WILL BE UTILIZED. PRE-EMERGENT HERBICIDES SHALL BE APPLIED PER THE MANUFACTURER'S LABELED RATES. METHODS A. SOIL PREPARATION 1. BEFORE STARTING WORK, THE LANDSCAPE CONTRACTOR SHALL VERIFY THAT THE GRADE OF ALL LANDSCAPE AREAS ARE WITHIN +/-0.1' OF FINISH GRADE. THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY SHOULD ANY DISCREPANCIES EXIST. 2. SOIL TESTING: a. AFTER FINISH GRADES HAVE BEEN ESTABLISHED, CONTRACTOR SHALL HAVE SOIL SAMPLES TESTED BY AN ESTABLISHED SOIL TESTING LABORATORY FOR THE FOLLOWING: SOIL TEXTURAL CLASS, GENERAL SOIL FERTILITY, pH, ORGANIC MATTER CONTENT, SALT (CEC), LIME, SODIUM ADSORPTION RATIO (SAR) AND BORON CONTENT. EACH SAMPLE SUBMITTED SHALL CONTAIN NO LESS THAN ONE QUART OF SOIL. b. CONTRACTOR SHALL ALSO SUBMIT THE PROJECT'S PLANT LIST TO THE LABORATORY ALONG WITH THE SOIL SAMPLES. c. THE SOIL REPORT PRODUCED BY THE LABORATORY SHALL CONTAIN RECOMMENDATIONS FOR THE FOLLOWING (AS APPROPRIATE): GENERAL SOIL PREPARATION AND BACKFILL MIXES, PRE-PLANT FERTILIZER APPLICATIONS, AND ANY OTHER SOIL RELATED ISSUES. THE REPORT SHALL ALSO PROVIDE A FERTILIZER PROGRAM FOR THE ESTABLISHMENT PERIOD AND FOR LONG-TERM MAINTENANCE. 3. THE CONTRACTOR SHALL INSTALL SOIL AMENDMENTS AND FERTILIZERS PER THE SOILS REPORT RECOMMENDATIONS. ANY CHANGE IN COST DUE TO THE SOIL REPORT RECOMMENDATIONS, EITHER INCREASE OR DECREASE, SHALL BE SUBMITTED TO THE OWNER WITH THE REPORT. 4. FOR BIDDING PURPOSES ONLY , THE SOIL PREPARATION SHALL CONSIST OF THE FOLLOWING: a. TURF: INCORPORATE THE FOLLOWING AMENDMENTS INTO THE TOP 8" OF SOIL BY MEANS OF ROTOTILLING AFTER CROSS-RIPPING: i. NITROGEN STABILIZED ORGANIC AMENDMENT - 4 CU. YDS. PER 1,000 S.F. ii. AMMONIUM PHOSPHATE 16-20-0 - 15 LBS PER 1,000 S.F. iii. AGRICULTURAL GYPSUM - 100 LBS PER 1,000 S.F. b. TREES, SHRUBS, AND PERENNIALS: INCORPORATE THE FOLLOWING AMENDMENTS INTO THE TOP 8" OF SOIL BY MEANS OF ROTOTILLING AFTER CROSS-RIPPING: i. NITROGEN STABILIZED ORGANIC AMENDMENT - 4 CU. YDS. PER 1,000 S.F. ii. 12-12-12 FERTILIZER - 10 LBS. PER CU. YD. iii. AGRICULTURAL GYPSUM - 10 LBS. PER CU. YD. iv. IRON SULPHATE - 2 LBS. PER CU. YD. 5. CONTRACTOR SHALL ENSURE THAT THE GRADE IN SOD AREAS SHALL BE 1" BELOW FINISH GRADE BEFORE INSTALLING SOIL AMENDMENTS, AND 2" BELOW FINISH GRADE IN SHRUB AREAS BEFORE INSTALLING SOIL AMENDMENTS. MULCH COVER WITHIN 6" OF CONCRETE WALKS AND CURBS SHALL NOT PROTRUDE ABOVE THE FINISH SURFACE OF THE WALKS AND CURBS. MULCH COVER WITHIN 12" OF WALLS SHALL BE AT LEAST 3" LOWER THAN THE TOP OF WALL. 6. ONCE SOIL PREPARATION IS COMPLETE, THE LANDSCAPE CONTRACTOR SHALL ENSURE THAT THERE ARE NO DEBRIS, TRASH, OR STONES LARGER THAN 1" REMAINING IN THE TOP 6" OF SOIL. 5 6 7 4 1 8 9 11 10 12 PREVAILING WINDS NOTES: 1. SCARIFY SIDES OF PLANTING PIT PRIOR TO SETTING TREE. 2. REMOVE EXCESS SOIL APPLIED ON TOP OF THE ROOTBALL THAT COVERS THE ROOT FLARE. THE PLANTING HOLE DEPTH SHALL BE SUCH THAT THE ROOTBALL RESTS ON UNDISTURBED SOIL, AND THE ROOT FLARE IS 3"-5" ABOVE FINISH GRADE. 3. FOR B&B TREES, CUT OFF BOTTOM 1/3 OF WIRE BASKET BEFORE PLACING TREE IN HOLE, CUT OFF AND REMOVE REMAINDER OF BASKET AFTER TREE IS SET IN HOLE, REMOVE ALL NYLON TIES, TWINE, ROPE, AND OTHER PACKING MATERIAL. REMOVE AS MUCH BURLAP FROM AROUND ROOTBALL AS IS PRACTICAL. 4. REMOVE ALL NURSERY STAKES AFTER PLANTING. 5. FOR TREES OVER 3" CALIPER AND TREES 36" BOX AND LARGER, USE THREE STAKES OR DEADMEN (AS APPROPRIATE), SPACED EVENLY AROUND TREE. 6. STAKING SHALL BE TIGHT ENOUGH TO PREVENT TRUNK FROM BENDING, BUT LOOSE ENOUGH TO ALLOW SOME TRUNK MOVEMENT IN WIND. 1 2 3 TREE CANOPY. CINCH-TIES (24" BOX TREES AND SMALLER) OR 12 GAUGE GALVANIZED WIRE WITH NYLON TREE STRAPS AT TREE AND STAKE (36" BOX TREES AND LARGER). SECURE TIES OR STRAPS TO TRUNK JUST ABOVE LOWEST MAJOR BRANCHES. GREEN STEEL T-POSTS. EXTEND POSTS 12" MIN. INTO UNDISTURBED SOIL. 24" X 3/4" P.V.C. MARKERS OVER WIRES. PRESSURE-TREATED WOOD DEADMAN, TWO PER TREE (MIN.). BURY OUTSIDE OF PLANTING PIT AND 18" MIN. INTO UNDISTURBED SOIL. MULCH, TYPE AND DEPTH PER PLANS. DO NOT PLACE MULCH WITHIN 6" OF TRUNK. FINISH GRADE. BACKFILL. AMEND AND FERTILIZE ONLY AS RECOMMENDED IN SOIL FERTILITY ANALYSIS. ROOT BALL. UNDISTURBED NATIVE SOIL. 4" HIGH EARTHEN WATERING BASIN. TRUNK FLARE. CONIFEROUS TREE PREVAILING WINDS STAKING EXAMPLES (PLAN VIEW) 2 4 6 7 8 9 10 11 1 4 3X ROOTBALL DIA. 5 2 3 5 12 TREE PLANTING A SCALE: NOT TO SCALE NON-CONIFEROUS TREE B. GENERAL PLANTING 1. REMOVE ALL NURSERY TAGS AND STAKES FROM PLANTS. 2. EXCEPT IN AREAS TO BE PLANTED WITH ORNAMENTAL GRASSES, APPLY PRE-EMERGENT HERBICIDES AT THE MANUFACTURER'S RECOMMENDED RATE. 3. TRENCHING NEAR EXISTING TREES: a. CONTRACTOR SHALL NOT DISTURB ROOTS 1-1/2" AND LARGER IN DIAMETER WITHIN THE CRITICAL ROOT ZONE (CRZ) OF EXISTING TREES, AND SHALL EXERCISE ALL POSSIBLE CARE AND PRECAUTIONS TO AVOID INJURY TO TREE ROOTS, TRUNKS, AND BRANCHES. THE CRZ IS DEFINED AS A CIRCULAR AREA EXTENDING OUTWARD FROM THE TREE TRUNK, WITH A RADIUS EQUAL TO 1' FOR EVERY 1" OF TRUNK DIAMETER-AT-BREAST-HEIGHT (4.5' ABOVE THE AVERAGE GRADE AT THE TRUNK). b. ALL EXCAVATION WITHIN THE CRZ SHALL BE PERFORMED USING HAND TOOLS. NO MACHINE EXCAVATION OR TRENCHING OF ANY KIND SHALL BE ALLOWED WITHIN THE CRZ. c. ALTER ALIGNMENT OF PIPE TO AVOID TREE ROOTS 1-1/2" AND LARGER IN DIAMETER. WHERE TREE ROOTS 1-1/2" AND LARGER IN DIAMETER ARE ENCOUNTERED IN THE FIELD, TUNNEL UNDER SUCH ROOTS. WRAP EXPOSED ROOTS WITH SEVERAL LAYERS OF BURLAP AND KEEP MOIST. CLOSE ALL TRENCHES WITHIN THE CANOPY DRIP LINES WITHIN 24 HOURS. d. ALL SEVERED ROOTS SHALL BE HAND PRUNED WITH SHARP TOOLS AND ALLOWED TO AIR-DRY. DO NOT USE ANY SORT OF SEALERS OR WOUND PAINTS. C. TREE PLANTING 1. TREE PLANTING HOLES SHALL BE EXCAVATED TO MINIMUM WIDTH OF TWO TIMES THE WIDTH OF THE ROOTBALL, AND TO A DEPTH EQUAL TO THE DEPTH OF THE ROOTBALL LESS TWO TO FOUR INCHES. 2. SCARIFY THE SIDES AND BOTTOM OF THE PLANTING HOLE PRIOR TO THE PLACEMENT OF THE TREE. REMOVE ANY GLAZING THAT MAY HAVE BEEN CAUSED DURING THE EXCAVATION OF THE HOLE. 3. FOR CONTAINER AND BOX TREES, TO REMOVE ANY POTENTIALLY GIRDLING ROOTS AND OTHER ROOT DEFECTS, THE CONTRACTOR SHALL SHAVE A 1" LAYER OFF OF THE SIDES AND BOTTOM OF THE ROOTBALL OF ALL TREES JUST BEFORE PLACING INTO THE PLANTING PIT. DO NOT "TEASE" ROOTS OUT FROM THE ROOTBALL. 4. INSTALL THE TREE ON UNDISTURBED SUBGRADE SO THAT THE TOP OF THE ROOTBALL IS TWO TO FOUR INCHES ABOVE THE SURROUNDING GRADE. 5. BACKFILL THE TREE HOLE UTILIZING THE EXISTING TOPSOIL FROM ON-SITE. ROCKS LARGER THAN 1" DIA. AND ALL OTHER DEBRIS SHALL BE REMOVED FROM THE SOIL PRIOR TO THE BACKFILL. SHOULD ADDITIONAL SOIL BE REQUIRED TO ACCOMPLISH THIS TASK, USE STORED TOPSOIL FROM ON-SITE OR IMPORT ADDITIONAL TOPSOIL FROM OFF-SITE AT NO ADDITIONAL COST TO THE OWNER. IMPORTED TOPSOIL SHALL BE OF SIMILAR TEXTURAL CLASS AND COMPOSITION IN THE ON-SITE SOIL. 6. THE TOTAL NUMBER OF TREE STAKES (BEYOND THE MINIMUMS LISTED BELOW) WILL BE LEFT TO THE LANDSCAPE CONTRACTOR'S DISCRETION. SHOULD ANY TREES FALL OR LEAN, THE LANDSCAPE CONTRACTOR SHALL STRAIGHTEN THE TREE, OR REPLACE IT SHOULD IT BECOME DAMAGED. TREE STAKING SHALL ADHERE TO THE FOLLOWING GUIDELINES: a. 1"-2" TREES TWO STAKES PER TREE b. 2-1/2"-4" TREES THREE STAKES PER TREE c. TREES OVER 4" CALIPER GUY AS NEEDED d. MULTI-TRUNK TREES THREE STAKES PER TREE MINIMUM, QUANTITY AND POSITIONS AS NEEDED TO STABILIZE THE TREE 7. UPON COMPLETION OF PLANTING, CONSTRUCT AN EARTH WATERING BASIN AROUND THE TREE. COVER THE INTERIOR OF THE TREE RING WITH MULCH (TYPE AND DEPTH PER PLANS). D. SHRUB, PERENNIAL, AND GROUNDCOVER PLANTING 1. DIG THE PLANTING HOLES TWICE AS WIDE AND 2" LESS DEEP THAN EACH PLANT'S ROOTBALL. INSTALL THE PLANT IN THE HOLE. BACKFILL AROUND THE PLANT WITH SOIL AMENDED PER SOIL TEST RECOMMENDATIONS. 2. WHEN PLANTING IS COMPLETE, INSTALL MULCH (TYPE AND DEPTH PER PLANS) OVER ALL PLANTING BEDS, COVERING THE ENTIRE PLANTING AREA. E. SODDING 1. SOD VARIETY TO BE AS SPECIFIED ON THE LANDSCAPE PLAN. 2. LAY SOD WITHIN 24 HOURS FROM THE TIME OF STRIPPING. DO NOT LAY IF THE GROUND IS FROZEN. 3. LAY THE SOD TO FORM A SOLID MASS WITH TIGHTLY FITTED JOINTS. BUTT ENDS AND SIDES OF SOD STRIPS - DO NOT OVERLAP. STAGGER STRIPS TO OFFSET JOINTS IN ADJACENT COURSES. 4. ROLL THE SOD TO ENSURE GOOD CONTACT OF THE SOD'S ROOT SYSTEM WITH THE SOIL UNDERNEATH. 5. WATER THE SOD THOROUGHLY WITH A FINE SPRAY IMMEDIATELY AFTER PLANTING TO OBTAIN AT LEAST SIX INCHES OF PENETRATION INTO THE SOIL BELOW THE SOD. F. HYDROMULCHING 1. HYDROMULCH MIX (PER 1,000 SF) SHALL BE AS FOLLOWS: a. WINTER MIX (OCTOBER 1 - MARCH 31) 50# CELLULOSE FIBER MULCH 2# KENTUCKY BLUEGRASS SEED 15# 15-15-15 WATER SOLUBLE FERTILIZER G. CLEAN UP 1. DURING LANDSCAPE PREPARATION AND PLANTING, KEEP ALL PAVEMENT CLEAN AND ALL WORK AREAS IN A NEAT, ORDERLY CONDITION. 2. DISPOSED LEGALLY OF ALL EXCAVATED MATERIALS OFF THE PROJECT SITE. H. INSPECTION AND ACCEPTANCE 1. UPON COMPLETION OF THE WORK, THE LANDSCAPE CONTRACTOR SHALL PROVIDE THE SITE CLEAN, FREE OF DEBRIS AND TRASH, AND SUITABLE FOR USE AS INTENDED. THE LANDSCAPE CONTRACTOR SHALL THEN REQUEST AN INSPECTION BY THE OWNER TO DETERMINE FINAL ACCEPTABILITY. 2. WHEN THE INSPECTED PLANTING WORK DOES NOT COMPLY WITH THE CONTRACT DOCUMENTS, THE LANDSCAPE CONTRACTOR SHALL REPLACE AND/OR REPAIR THE REJECTED WORK TO THE OWNER'S SATISFACTION WITHIN 24 HOURS. 3. THE LANDSCAPE MAINTENANCE PERIOD WILL NOT COMMENCE UNTIL THE LANDSCAPE WORK HAS BEEN RE-INSPECTED BY THE OWNER AND FOUND TO BE ACCEPTABLE. AT THAT TIME, A WRITTEN NOTICE OF FINAL ACCEPTANCE WILL BE ISSUED BY THE OWNER, AND THE MAINTENANCE AND GUARANTEE PERIODS WILL COMMENCE. I. LANDSCAPE MAINTENANCE 1. THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL WORK SHOWN ON THESE PLANS FOR 90 DAYS BEYOND FINAL ACCEPTANCE OF ALL LANDSCAPE WORK BY THE OWNER. LANDSCAPE MAINTENANCE SHALL INCLUDE WEEKLY SITE VISITS FOR THE FOLLOWING ACTIONS (AS APPROPRIATE): PROPER PRUNING, RESTAKING OF TREES, RESETTING OF PLANTS THAT HAVE SETTLED, MOWING AND AERATION OF LAWNS, WEEDING, RESEEDING AREAS WHICH HAVE NOT GERMINATED WELL, TREATING FOR INSECTS AND DISEASES,REPLACEMENT OF MULCH, REMOVAL OF LITTER, REPAIRS TO THE IRRIGATION SYSTEM DUE TO FAULTY PARTS AND/OR WORKMANSHIP, AND THE APPROPRIATE WATERING OF ALL PLANTINGS. THE LANDSCAPE CONTRACTOR SHALL MAINTAIN THE IRRIGATION SYSTEM IN PROPER WORKING ORDER, WITH SCHEDULING ADJUSTMENTS BY SEASON TO MAXIMIZE WATER CONSERVATION. 2. SHOULD SEEDED AND/OR SODDED AREAS NOT BE COVERED BY AN AUTOMATIC IRRIGATION SYSTEM, THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR WATERING THESE AREAS AND OBTAINING A FULL, HEALTHY STAND OF GRASS AT NO ADDITIONAL COST TO THE OWNER. 3. TO ACHIEVE FINAL ACCEPTANCE AT THE END OF THE MAINTENANCE PERIOD, ALL OF THE FOLLOWING CONDITIONS MUST OCCUR: a. THE LANDSCAPE SHALL SHOW ACTIVE, HEALTHY GROWTH (WITH EXCEPTIONS MADE FOR SEASONAL DORMANCY). ALL PLANTS NOT MEETING THIS CONDITION SHALL BE REJECTED AND REPLACED BY HEALTHY PLANT MATERIAL PRIOR TO FINAL ACCEPTANCE. b. ALL HARDSCAPE SHALL BE CLEANED PRIOR TO FINAL ACCEPTANCE. c. SODDED AREAS MUST BE ACTIVELY GROWING AND MUST REACH A MINIMUM HEIGHT OF 1 1/2 INCHES BEFORE FIRST MOWING. HYDROMULCHED AREAS SHALL SHOW ACTIVE, HEALTHY GROWTH. BARE AREAS LARGER THAN TWELVE SQUARE INCHES MUST BE RESODDED OR RESEEDED (AS APPROPRIATE) PRIOR TO FINAL ACCEPTANCE. ALL SODDED TURF SHALL BE NEATLY MOWED. J. WARRANTY PERIOD, PLANT GUARANTEE AND REPLACEMENTS 1. THE LANDSCAPE CONTRACTOR SHALL GUARANTEE ALL TREES, SHRUBS, PERENNIALS, SOD, SEEDED/HYDROMULCHED AREAS, AND IRRIGATION SYSTEMS FOR A PERIOD OF ONE YEAR FROM THE DATE OF THE OWNER'S FINAL ACCEPTANCE (90 DAYS FOR ANNUAL PLANTS). THE CONTRACTOR SHALL REPLACE, AT HIS OWN EXPENSE AND TO THE SATISFACTION OF THE OWNER, ANY PLANTS WHICH DIE IN THAT TIME, OR REPAIR ANY PORTIONS OF THE IRRIGATION SYSTEM WHICH OPERATE IMPROPERLY. 2. AFTER THE INITIAL MAINTENANCE PERIOD AND DURING THE GUARANTEE PERIOD, THE LANDSCAPE CONTRACTOR SHALL ONLY BE RESPONSIBLE FOR REPLACEMENT OF PLANTS WHEN PLANT DEATH CANNOT BE ATTRIBUTED DIRECTLY TO OVERWATERING OR OTHER DAMAGE BY HUMAN ACTIONS. K. PROVIDE A MINIMUM OF (2) COPIES OF RECORD DRAWINGS TO THE OWNER UPON COMPLETION OF WORK. A RECORD DRAWING IS A RECORD OF ALL CHANGES THAT OCCURRED IN THE FIELD AND THAT ARE DOCUMENTED THROUGH CHANGE ORDERS, ADDENDA, OR CONTRACTOR/CONSULTANT DRAWING MARKUPS. E 17725 N Katy Freeway, G Suite I 103 N Houston, E TX E 77094 R Phone: I 281.N 506.7119 G Firm TBPE Registration No. F-12959 www.dacengineers.com LP2 L A W R A N C E M . L E S S E R 1 8 8 (800) 680-6630 1780 Heritage Center Dr., Suite 104 Wake Forest, NC 27587 www.landscape-consultants.net D E S I G N G R O U P Celebrating 10 Years CITY APPROVALS CONTRACTOR TO CONTACT THE UTILITY NOTIFICATION CENTER OF COLORADO AT 1-800-922-1987 OR 811 AT LEAST THREE DAYS BEFORE DIGGING TO LOCATE ALL UNDERGROUND UTILITIES. BENCHMARKS FLOODPLAIN PROPOSED CHRISTIAN BROTHERS AUTOMOTIVE 1.857 ACRES IN LOT 1, TRACT A OF THE SOUTHWEST QUARTER OF SECTION 1, TOWNSHIP 6 NORTH FORT COLLINS, CO PLANTING SPECIFICATIONS AND DETAILS PLANTING LEGEND SYMBOL BOTANIC NAME COMMON NAME SIZE SPACING QUANTITY REMARKS NOTE: ALL TREES SHALL BE BALLED AND BURLAPPED. REMOVE ALL BURLAP AND WIRE BEFORE PLANTING. SEE SPECIFICATIONS FOR PROPER ROOT QUALITY. 'Reveille' Bluegrass Sod - - - - - - 15 15 14 62 4 12 13 6' o.c. 1' o.c. 3' o.c. 3' o.c. Per plan Per plan Per plan Poa x 'Reveille' Autumn Amber Fragrant Sumac Purple Penstemon Blue Spiraea Foxtail Pine Kentucky Coffee Tree Sunburst Honeylocust Dwarf Russian Pea #3 cont. #1 cont. #3 cont. #5 cont. RHAR Rhus aromatica 'Autumn Amber' PEPP Penstemon mexicali 'Pikes Peak Purple' CACLclandonensis Caryopteris PIARaristata Pinushigh 6' GYDI Gymnocladus dioica 2" cal., 8'-10' high GLTR Gleditsia triacanthos 'Sunburst' 2" cal., 8'-10' high CAPY TURF AND SEED Caragana pygmaea SHRUBS AND PERENNIALS TREES GENERAL PLANTING NOTES 1. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVING ALL EXISTING VEGETATION (EXCEPT WHERE NOTED TO REMAIN). BEFORE STARTING WORK, THE LANDSCAPE CONTRACTOR SHALL VERIFY THAT THE GRADE OF ALL LANDSCAPE AREAS ARE WITHIN +/-0.1' OF FINISH GRADE. THE LANDSCAPE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY SHOULD ANY DISCREPANCIES EXIST. SEE SPECIFICATIONS FOR MORE DETAILED INSTRUCTION ON TURF AREA AND PLANTING BED PREPARATION. 2. CONSTRUCT AND MAINTAIN FINISH GRADES IN LANDSCAPE AREAS AS SHOWN ON GRADING PLANS, AND CONSTRUCT AND MAINTAIN SLOPES AS RECOMMENDED BY THE GEOTECHNICAL REPORT. ALL LANDSCAPE AREAS SHALL HAVE POSITIVE DRAINAGE AWAY FROM STRUCTURES AT THE MINIMUM SLOPE SPECIFIED IN THE REPORT, AND AREAS OF POTENTIAL PONDING SHALL BE REGRADED TO BLEND IN WITH THE SURROUNDING GRADES AND ELIMINATE PONDING POTENTIAL. SHOULD ANY CONFLICTS AND/OR DISCREPANCIES ARISE BETWEEN THE GRADING PLANS, GEOTECHNICAL REPORT, THESE NOTES, AND ACTUAL CONDITIONS, THE CONTRACTOR SHALL IMMEDIATELY BRING SUCH ITEMS TO THE ATTENTION OF THE LANDSCAPE ARCHITECT, GENERAL CONTRACTOR, AND OWNER. 3. ENSURE THAT THE GRADE IN SHRUB AREAS SHALL BE 2" BELOW FINISH GRADE AFTER INSTALLING SOIL AMENDMENTS, AND 1" BELOW FINISH GRADE IN SOD AREAS AFTER INSTALLING SOIL AMENDMENTS. MULCH COVER WITHIN 6" OF CONCRETE WALKS AND CURBS SHALL NOT PROTRUDE ABOVE THE FINISH SURFACE OF THE WALKS AND CURBS. MULCH COVER WITHIN 12" OF WALLS SHALL BE AT LEAST 3" LOWER THAN THE TOP OF WALL. 4. INSTALL MULCH TOPDRESSING, TYPE AND DEPTH PER MULCH NOTE, IN ALL PLANTING BEDS AND TREE RINGS. DO NOT INSTALL MULCH WITHIN 6" OF TREE ROOT FLARE. 5. INSTALL 14G, GREEN STEEL EDGING BETWEEN ALL PLANTING BEDS AND TURF AREAS, AND BETWEEN GROUNDCOVERS AND OTHER PLANTS (WHERE INDICATED ON THE PLAN). 6. HYDROSEED ALL DISTURBED AREAS OUTSIDE OF PROPERTY LIMITS (UNLESS SHOWN AS SOD). 7. ALL PLANT LOCATIONS ARE DIAGRAMMATIC. ACTUAL LOCATIONS SHALL BE VERIFIED WITH THE LANDSCAPE ARCHITECT OR DESIGNER PRIOR TO PLANTING. THE LANDSCAPE CONTRACTOR SHALL ENSURE THAT ALL REQUIREMENTS OF THE PERMITTING AUTHORITY ARE MET (I.E., MINIMUM PLANT QUANTITIES, PLANTING METHODS, TREE PROTECTION METHODS, ETC.). 8. THE LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR DETERMINING PLANT QUANTITIES; PLANT QUANTITIES SHOWN ON LEGENDS AND CALLOUTS ARE FOR GENERAL INFORMATION ONLY. IN THE EVENT OF A DISCREPANCY BETWEEN THE PLAN AND THE PLANT LEGEND, THE PLANT QUANTITY AS SHOWN ON THE PLAN (FOR INDIVIDUAL SYMBOLS) OR CALLOUT (FOR GROUNDCOVER PATTERNS) SHALL TAKE PRECEDENCE. 9. NO SUBSTITUTIONS OF PLANT MATERIALS SHALL BE ALLOWED WITHOUT THE WRITTEN PERMISSION OF THE LANDSCAPE ARCHITECT. IF SOME OF THE PLANTS ARE NOT AVAILABLE, THE LANDSCAPE CONTRACTOR SHALL NOTIFY THE LANDSCAPE ARCHITECT IN WRITING (VIA PROPER CHANNELS). 10. PLANTS MAY BE INSPECTED AND APPROVED OR REJECTED ON THE JOBSITE BY THE OWNER OR OWNER'S REPRESENTATIVE. 11. THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL WORK SHOWN ON THESE PLANS FOR 90 DAYS BEYOND FINAL ACCEPTANCE OF ALL LANDSCAPE WORK BY THE OWNER. LANDSCAPE MAINTENANCE SHALL INCLUDE WEEKLY SITE VISITS FOR THE FOLLOWING ACTIONS (AS APPROPRIATE): PROPER PRUNING, RESTAKING OF TREES, RESETTING OF PLANTS THAT HAVE SETTLED, MOWING AND AERATION OF LAWNS, WEEDING, RESEEDING AREAS WHICH HAVE NOT GERMINATED WELL, TREATING FOR INSECTS AND DISEASES,REPLACEMENT OF MULCH, REMOVAL OF LITTER, REPAIRS TO THE IRRIGATION SYSTEM DUE TO FAULTY PARTS AND/OR WORKMANSHIP, AND THE APPROPRIATE WATERING OF ALL PLANTINGS. THE LANDSCAPE CONTRACTOR SHALL MAINTAIN THE IRRIGATION SYSTEM IN PROPER WORKING ORDER, WITH SCHEDULING ADJUSTMENTS BY SEASON TO MAXIMIZE WATER CONSERVATION. 12. SHOULD SEEDED AND/OR SODDED AREAS NOT BE COVERED BY AN AUTOMATIC IRRIGATION SYSTEM, THE LANDSCAPE CONTRACTOR SHAL BE RESPONSIBLE FOR WATERING THESE AREAS AND OBTAINING A FULL STAND OF GRASS AT NO ADDITIONAL COST TO THE OWNER. 13. TO ACHIEVE FINAL ACCEPTANCE AT THE END OF THE MAINTENANCE PERIOD, ALL OF THE FOLLOWING CONDITIONS MUST OCCUR: A. THE LANDSCAPE SHALL SHOW ACTIVE, HEALTHY GROWTH (WITH EXCEPTIONS MADE FOR SEASONAL DORMANCY). ALL PLANTS NOT MEETING THIS CONDITION SHALL BE REJECTED AND REPLACED BY HEALTHY PLANT MATERIAL PRIOR TO FINAL ACCEPTANCE. B. ALL HARDSCAPE SHALL BE CLEANED PRIOR TO FINAL ACCEPTANCE. C. SODDED AREAS MUST BE ACTIVELY GROWING AND MUST REACH A MINIMUM HEIGHT OF 1 1/2 INCHES BEFORE FIRST MOWING. HYDROMULCHED AREAS SHALL SHOW ACTIVE, HEALTHY GROWTH. BARE AREAS LARGER THAN TWELVE SQUARE INCHES MUST BE RESODDED OR RESEEDED (AS APPROPRIATE) PRIOR TO FINAL ACCEPTANCE. ALL SODDED TURF SHALL BE NEATLY MOWED. 14. SEE SPECIFICATIONS AND DETAILS FOR FURTHER REQUIREMENTS. QUMUmuehlenbergii Quercus Chinquapinplan Oak 2" cal., 8'-10' high Per 3 PIMU Pinushigh mugo 'Big Tuna' Big Tuna Mugo Pine 3' 4'-5' o.c. 25 JUOG Juniperus x 'Old Gold' Old Gold Juniper #5 cont.4' o.c. 19 CRAMambigua Crataegus Russianplan Hawthorn 2" cal., 8'-10' high Per 4 TBD Detention border seed mix Seed - - - - - - TBD Detention basin seed mix Seed - - - - - - - - - Rainaverage Garden Perennial Mix #1 cont.2' o.c. 170 See below for species mix RAIN GARDEN PLANTS SHALL BE AN EVEN MIX OF THE FOLLOWING SPECIES, IN RANDOM GROUPINGS OF THREE TO SEVEN: AGASTACHE RUPESTRIS PENSTEMON MEXICALI 'PIKES PEAK PURPLE' SCHIZACHYRIUM SCOPARIUM M . L E S S E R 1 8 8 (800) 680-6630 1780 Heritage Center Dr., Suite 104 Wake Forest, NC 27587 www.landscape-consultants.net D E S I G N G R O U P Celebrating 10 Years CITY APPROVALS CONTRACTOR TO CONTACT THE UTILITY NOTIFICATION CENTER OF COLORADO AT 1-800-922-1987 OR 811 AT LEAST THREE DAYS BEFORE DIGGING TO LOCATE ALL UNDERGROUND UTILITIES. BENCHMARKS FLOODPLAIN PROPOSED CHRISTIAN BROTHERS AUTOMOTIVE 1.857 ACRES IN LOT 1, TRACT A OF THE SOUTHWEST QUARTER OF SECTION 1, TOWNSHIP 6 NORTH FORT COLLINS, CO PLANTING PLAN SEE SHEET LP2 FOR PLANT LEGEND STEEL EDGING BETWEEN TURF AND SHRUBS (TYP.) 1 QUMU 3 JUOG 1 QUMU 4 JUOG 1 QUMU 16JUOG CAPY 4 3 GLTR 3 CACL 15 PEPP 15 CAPY 3 RHAR 5 CACL 7 CAPY 3 PIMU 6 PIMU 3 PIMU 4 RHAR 15 CAPY 5 PIMU 9 CAPY 8 PIMU 8 JUOG 6 CACL 8 RHAR 6 GYDI 4 CRAM 6 GYDI 10 GLTR EXISTING TREES - PROTECT IN PLACE RAIN GARDEN ROCK MULCH - 4" THICK LAYER OF 1"-2" COBBLE OVER LANDSCAPE FABRIC WATER USE CALCULATIONS 39,316 SF LOW-WATER TURF 39,316 SF X 10 GAL/SF = 393,160 GAL/SF/SEASON 13,927 SF BASIN AND RAIN GARDEN 13,927 SF X 3 GAL/SF = 41,781 GAL/SF/SEASON 3,513 SF SHRUBS 3,513 SF X 3 GAL/SF = 10,539 GAL/SF/SEASON 445,480 GAL / 61,453 SF = 7.25 GAL/SF/SEASON