Loading...
HomeMy WebLinkAboutSOUTHEAST FORT COLLINS COMMUNITY PARK - PDP - PDP140014 - PLANS - UTILITY PLANSCOVER SHEET CV - 1 01 of 21 vicinity map Scale: NTS OWNER City of Fort Collins Park Planning and Development 215 Mason Street Fort Collins, Colorado 80524 Ph. 970.221.6367 Contact: Craig Kisling SURVEYOR City of Fort Collins Surveying Department 281 N. College Ave Fort Collins, Colorado 80524 Ph. 970.221.6565 Contact: John Von Nieda DATE I HEREBY AFFIRM THAT THESE FINAL CONSTRUCTION PLANS WERE PREPARED UNDER MY DIRECT SUPERVISION, IN ACCORDANCE WITH ALL APPLICABLE CITY OF FORT COLLINS AND STATE OF COLORADO STANDARDS AND STATUES, RESPECTIVELY; AND THAT I AM FULLY RESPONSIBLE FOR THE ACCURACY OF ALL DESIGN REVISIONS, AND RECORD CONDITIONS THAT I HAVE NOTED ON THE PLANS. ABBREVIATION LIST AE ACCESS EASEMENT BOV BLOW OFF VALVE BT BOTTOM OF TRENCH BW BOTTOM OF WALL C&G CURB AND GUTTER CL CENTERLINE CMP CORRUGATED METAL PIPE DE DRAINAGE EASEMENT INV INVERT IRR IRRIGATION LF LINEAR FEET LP LOW POINT LT LEFT MH MANHOLE PE PEDESTRIAN EASEMENT PVC POLYVINYL CHLORIDE RCP REINFORCED CONCRETE PIPE PROPOSED STORM SEWER & MANHOLE EXISTING SANITARY SEWER MAIN PROPOSED TELEPHONE LINE EXISTING GAS EXISTING STORM SEWER EXISTING WATER MAIN EXISTING MANHOLE PROPOSED STORM INLET LEGEND PROPOSED CONCRETE PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PLAYGROUND BMX TRACK (TO BE DESIGNED BY OTHERS) BASEBALL FIELD BASEBALL FIELD DOG PARK CREEK PLAY AREA EXISTING IRRIGATION & DETENTION POND 0 SCALE: 1" = 80' 80 40 80 160 OVERALL UTILITY PLAN UT-1 02 of 21 LEGEND EXISTING FLOODPLAIN PROPOSED FLOODPLAIN 2" WATER SERVICE 6" SANITARY SERVICE SOLID PIPE STORM SYSTEM PERF PIPE STORM SYSTEM NOTES 1. ALL WATER CONSTRUCTION SHALL BE IN ACCORDANCE WITH FORT COLLINS - LOVELAND WATER DISTRICT STANDARDS AND SPECIFICATIONS. ALL SANITARY SEWER CONSTRUCITON SHALL BE IN ACCORDANCE WITH SOUTH FORT COLLINS SANITATION DISTRICT STANDARDS AND SPECIFICATIONS. ALL STORM PIPE CONSTRUCTION SHALL BE IN ACCORDANCE WITH CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS. 2. WATER SERVICE SHALL BE TYPE K SOFT COPPER FROM THE TAP TO THE METER PIT AND SHALL BE 2" DR9 HDPE PLASTIC PIPE (ASTM 2737) WITH TRACER WIRE. 3. 6-INCH SANITARY SEWER SERVICE SHALL BE PVC (SDR 35) @ 1.0% AS SPECIFIED BY THE SOUTH FORT COLLINS SANITATION DISTRICT. 4. ALL CLEANOUTS SHALL BE TRAFFIC RATED CLEANOUTS. 5. RCP STORM PIPES SHALL BE CLASS III AND BE INSTALLED AND BEDDED PER CITY OF FORT COLLINS STANDARDS. PLASTIC STORM DRAIN PIPES AND UNDERDRAINS SHALL BE HDPE SEWER PIPE OR PVC SEWER PIPE AS NOTED. PLASTIC PIPE BEDDING SHALL BE PER SANITARY SEWER BEDDING DETAIL. ALL STORM SEWER SHALL BE INSPECTED BY THE CITY OF FORT COLLINS. 6. ONSITE IMPROVEMENTS ARE TO BE PRIVATELY OWNED AND MAINTAINED BY THE PROPERTY OWNER. 7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE DONE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8. SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES IN THE BUFFER ZONE. 9. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. PROPOSED NATURAL AREA BUFFER All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. Mr. Terry Farrill, P.E., District Engineer Date Mr. Michael D. DiTullio, Manager Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan 0 SCALE: 1" = 30' 30 15 30 60 UTILITY PLAN UT-2 03 of 21 MATCH LINE - SEE SHEET UT-5 MATCH LINE - SEE SHEET UT-3 LEGEND EXISTING FLOODPLAIN PROPOSED FLOODPLAIN 2" WATER SERVICE 6" SANITARY SERVICE SOLID PIPE STORM SYSTEM UT-2 UT-5 UT-7 UT-3 UT-4 UT-6 PERF PIPE STORM SYSTEM PROPOSED NATURAL AREA BUFFER NOTES 1. ALL WATER CONSTRUCTION SHALL BE IN ACCORDANCE WITH FORT COLLINS - LOVELAND WATER DISTRICT STANDARDS AND SPECIFICATIONS. ALL SANITARY SEWER CONSTRUCITON SHALL BE IN ACCORDANCE WITH SOUTH FORT COLLINS SANITATION DISTRICT STANDARDS AND SPECIFICATIONS. ALL STORM PIPE CONSTRUCTION SHALL BE IN ACCORDANCE WITH CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS. 2. WATER SERVICE SHALL BE TYPE K SOFT COPPER FROM THE TAP TO THE METER PIT AND SHALL BE 2" DR9 HDPE PLASTIC PIPE (ASTM 2737) WITH TRACER WIRE. 3. 6-INCH SANITARY SEWER SERVICE SHALL BE PVC (SDR 35) @ 1.0% AS SPECIFIED BY THE SOUTH FORT COLLINS SANITATION DISTRICT. 4. ALL CLEANOUTS SHALL BE TRAFFIC RATED CLEANOUTS. 5. RCP STORM PIPES SHALL BE CLASS III AND BE INSTALLED AND BEDDED PER CITY OF FORT COLLINS STANDARDS. PLASTIC STORM DRAIN PIPES AND UNDERDRAINS SHALL BE HDPE SEWER PIPE OR PVC SEWER PIPE AS NOTED. PLASTIC PIPE BEDDING SHALL BE PER SANITARY SEWER BEDDING DETAIL. ALL STORM SEWER SHALL BE INSPECTED BY THE CITY OF FORT COLLINS. 6. ONSITE IMPROVEMENTS ARE TO BE PRIVATELY OWNED AND MAINTAINED BY THE PROPERTY OWNER. 7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE DONE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8. SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES IN THE BUFFER ZONE. All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. Mr. Terry Farrill, P.E., District Engineer Date Mr. Michael D. DiTullio, Manager Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan BASEBALL FIELD CREEK PLAY AREA 0 SCALE: 1" = 30' 30 15 30 60 UTILITY PLAN UT-3 04 of 21 MATCH LINE - SEE SHEET UT-6 MATCH LINE - SEE SHEET UT-3 MATCH LINE - SEE SHEET UT-2 NOTES 1. ALL WATER CONSTRUCTION SHALL BE IN ACCORDANCE WITH FORT COLLINS - LOVELAND WATER DISTRICT STANDARDS AND SPECIFICATIONS. ALL SANITARY SEWER CONSTRUCITON SHALL BE IN ACCORDANCE WITH SOUTH FORT COLLINS SANITATION DISTRICT STANDARDS AND SPECIFICATIONS. ALL STORM PIPE CONSTRUCTION SHALL BE IN ACCORDANCE WITH CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS. 2. WATER SERVICE SHALL BE TYPE K SOFT COPPER FROM THE TAP TO THE METER PIT AND SHALL BE 2" DR9 HDPE PLASTIC PIPE (ASTM 2737) WITH TRACER WIRE. 3. 6-INCH SANITARY SEWER SERVICE SHALL BE PVC (SDR 35) @ 1.0% AS SPECIFIED BY THE SOUTH FORT COLLINS SANITATION DISTRICT. 4. ALL CLEANOUTS SHALL BE TRAFFIC RATED CLEANOUTS. 5. RCP STORM PIPES SHALL BE CLASS III AND BE INSTALLED AND BEDDED PER CITY OF FORT COLLINS STANDARDS. PLASTIC STORM DRAIN PIPES AND UNDERDRAINS SHALL BE HDPE SEWER PIPE OR PVC SEWER PIPE AS NOTED. PLASTIC PIPE BEDDING SHALL BE PER SANITARY SEWER BEDDING DETAIL. ALL STORM SEWER SHALL BE INSPECTED BY THE CITY OF FORT COLLINS. 6. ONSITE IMPROVEMENTS ARE TO BE PRIVATELY OWNED AND MAINTAINED BY THE PROPERTY OWNER. 7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE DONE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8. SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES IN THE BUFFER ZONE. LEGEND EXISTING FLOODPLAIN PROPOSED FLOODPLAIN 2" WATER SERVICE 6" SANITARY SERVICE SOLID PIPE STORM SYSTEM PERF PIPE STORM SYSTEM PROPOSED NATURAL AREA BUFFER UT-2 UT-5 UT-7 UT-3 UT-4 UT-6 All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. Mr. Terry Farrill, P.E., District Engineer Date Mr. Michael D. DiTullio, Manager Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT BMX TRACK (TO BE DESIGNED BY OTHERS) BASEBALL FIELD RESTROOM FF=4903.20 0 SCALE: 1" = 30' 30 15 30 60 UTILITY PLAN UT-4 05 of 21 MATCH LINE - SEE SHEET UT-7 MATCH LINE - SEE SHEET UT-3 LEGEND EXISTING FLOODPLAIN PROPOSED FLOODPLAIN 2" WATER SERVICE 6" SANITARY SERVICE SOLID PIPE STORM SYSTEM PERF PIPE STORM SYSTEM PROPOSED NATURAL AREA BUFFER UT-2 UT-5 UT-7 UT-3 UT-4 UT-6 NOTES 1. ALL WATER CONSTRUCTION SHALL BE IN ACCORDANCE WITH FORT COLLINS - LOVELAND WATER DISTRICT STANDARDS AND SPECIFICATIONS. ALL SANITARY SEWER CONSTRUCITON SHALL BE IN ACCORDANCE WITH SOUTH FORT COLLINS SANITATION DISTRICT STANDARDS AND SPECIFICATIONS. ALL STORM PIPE CONSTRUCTION SHALL BE IN ACCORDANCE WITH CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS. 2. WATER SERVICE SHALL BE TYPE K SOFT COPPER FROM THE TAP TO THE METER PIT AND SHALL BE 2" DR9 HDPE PLASTIC PIPE (ASTM 2737) WITH TRACER WIRE. 3. 6-INCH SANITARY SEWER SERVICE SHALL BE PVC (SDR 35) @ 1.0% AS SPECIFIED BY THE SOUTH FORT COLLINS SANITATION DISTRICT. 4. ALL CLEANOUTS SHALL BE TRAFFIC RATED CLEANOUTS. 5. RCP STORM PIPES SHALL BE CLASS III AND BE INSTALLED AND BEDDED PER CITY OF FORT COLLINS STANDARDS. PLASTIC STORM DRAIN PIPES AND UNDERDRAINS SHALL BE HDPE SEWER PIPE OR PVC SEWER PIPE AS NOTED. PLASTIC PIPE BEDDING SHALL BE PER SANITARY SEWER BEDDING DETAIL. ALL STORM SEWER SHALL BE INSPECTED BY THE CITY OF FORT COLLINS. 6. ONSITE IMPROVEMENTS ARE TO BE PRIVATELY OWNED AND MAINTAINED BY THE PROPERTY OWNER. 7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE DONE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8. SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES IN THE BUFFER ZONE. All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. Mr. Terry Farrill, P.E., District Engineer Date Mr. Michael D. DiTullio, Manager Date FORT COLLINS - LOVELAND WATER DISTRICT 0 SCALE: 1" = 30' 30 15 30 60 UTILITY PLAN UT-5 06 of 21 MATCH LINE - SEE SHEET UT-6 MATCH LINE - SEE SHEET UT-2 LEGEND EXISTING FLOODPLAIN PROPOSED FLOODPLAIN 2" WATER SERVICE 6" SANITARY SERVICE SOLID PIPE STORM SYSTEM PERF PIPE STORM SYSTEM PROPOSED NATURAL AREA BUFFER UT-2 UT-5 UT-7 UT-3 UT-4 UT-6 NOTES 1. ALL WATER CONSTRUCTION SHALL BE IN ACCORDANCE WITH FORT COLLINS - LOVELAND WATER DISTRICT STANDARDS AND SPECIFICATIONS. ALL SANITARY SEWER CONSTRUCITON SHALL BE IN ACCORDANCE WITH SOUTH FORT COLLINS SANITATION DISTRICT STANDARDS AND SPECIFICATIONS. ALL STORM PIPE CONSTRUCTION SHALL BE IN ACCORDANCE WITH CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS. 2. WATER SERVICE SHALL BE TYPE K SOFT COPPER FROM THE TAP TO THE METER PIT AND SHALL BE 2" DR9 HDPE PLASTIC PIPE (ASTM 2737) WITH TRACER WIRE. 3. 6-INCH SANITARY SEWER SERVICE SHALL BE PVC (SDR 35) @ 1.0% AS SPECIFIED BY THE SOUTH FORT COLLINS SANITATION DISTRICT. 4. ALL CLEANOUTS SHALL BE TRAFFIC RATED CLEANOUTS. 5. RCP STORM PIPES SHALL BE CLASS III AND BE INSTALLED AND BEDDED PER CITY OF FORT COLLINS STANDARDS. PLASTIC STORM DRAIN PIPES AND UNDERDRAINS SHALL BE HDPE SEWER PIPE OR PVC SEWER PIPE AS NOTED. PLASTIC PIPE BEDDING SHALL BE PER SANITARY SEWER BEDDING DETAIL. ALL STORM SEWER SHALL BE INSPECTED BY THE CITY OF FORT COLLINS. 6. ONSITE IMPROVEMENTS ARE TO BE PRIVATELY OWNED AND MAINTAINED BY THE PROPERTY OWNER. 7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE DONE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8. SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES IN THE BUFFER ZONE. All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. Mr. Terry Farrill, P.E., District Engineer Date Mr. Michael D. DiTullio, Manager Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan PLAYGROUND RESTROOM FF=4902.00 PLAYGROUND BARN STRUCTURE FF=4902.50 PLAYGROUND 0 SCALE: 1" = 30' 30 15 30 60 UTILITY PLAN UT-6 07 of 21 MATCH LINE - SEE SHEET UT-6 MATCH LINE - SEE SHEET UT-5 MATCH LINE - SEE SHEET UT-3 LEGEND EXISTING FLOODPLAIN PROPOSED FLOODPLAIN 2" WATER SERVICE 6" SANITARY SERVICE SOLID PIPE STORM SYSTEM PERF PIPE STORM SYSTEM PROPOSED NATURAL AREA BUFFER UT-2 UT-5 UT-7 UT-3 UT-4 UT-6 NOTES 1. ALL WATER CONSTRUCTION SHALL BE IN ACCORDANCE WITH FORT COLLINS - LOVELAND WATER DISTRICT STANDARDS AND SPECIFICATIONS. ALL SANITARY SEWER CONSTRUCITON SHALL BE IN ACCORDANCE WITH SOUTH FORT COLLINS SANITATION DISTRICT STANDARDS AND SPECIFICATIONS. ALL STORM PIPE CONSTRUCTION SHALL BE IN ACCORDANCE WITH CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS. 2. WATER SERVICE SHALL BE TYPE K SOFT COPPER FROM THE TAP TO THE METER PIT AND SHALL BE 2" DR9 HDPE PLASTIC PIPE (ASTM 2737) WITH TRACER WIRE. 3. 6-INCH SANITARY SEWER SERVICE SHALL BE PVC (SDR 35) @ 1.0% AS SPECIFIED BY THE SOUTH FORT COLLINS SANITATION DISTRICT. 4. ALL CLEANOUTS SHALL BE TRAFFIC RATED CLEANOUTS. 5. RCP STORM PIPES SHALL BE CLASS III AND BE INSTALLED AND BEDDED PER CITY OF FORT COLLINS STANDARDS. PLASTIC STORM DRAIN PIPES AND UNDERDRAINS SHALL BE HDPE SEWER PIPE OR PVC SEWER PIPE AS NOTED. PLASTIC PIPE BEDDING SHALL BE PER SANITARY SEWER BEDDING DETAIL. ALL STORM SEWER SHALL BE INSPECTED BY THE CITY OF FORT COLLINS. 6. ONSITE IMPROVEMENTS ARE TO BE PRIVATELY OWNED AND MAINTAINED BY THE PROPERTY OWNER. 7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE DONE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8. SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES IN THE BUFFER ZONE. All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. Mr. Terry Farrill, P.E., District Engineer Date BMX TRACK (TO BE DESIGNED BY OTHERS) DOG PARK EXISTING IRRIGATION & DETENTION POND BASKETBALL COURT 0 SCALE: 1" = 30' 30 15 30 60 UTILITY PLAN UT-7 08 of 21 MATCH LINE - SEE SHEET UT-6 MATCH LINE - SEE SHEET UT-4 LEGEND EXISTING FLOODPLAIN PROPOSED FLOODPLAIN 2" WATER SERVICE 6" SANITARY SERVICE SOLID PIPE STORM SYSTEM PERF PIPE STORM SYSTEM PROPOSED NATURAL AREA BUFFER UT-2 UT-5 UT-7 UT-3 UT-4 UT-6 NOTES 1. ALL WATER CONSTRUCTION SHALL BE IN ACCORDANCE WITH FORT COLLINS - LOVELAND WATER DISTRICT STANDARDS AND SPECIFICATIONS. ALL SANITARY SEWER CONSTRUCITON SHALL BE IN ACCORDANCE WITH SOUTH FORT COLLINS SANITATION DISTRICT STANDARDS AND SPECIFICATIONS. ALL STORM PIPE CONSTRUCTION SHALL BE IN ACCORDANCE WITH CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS. 2. WATER SERVICE SHALL BE TYPE K SOFT COPPER FROM THE TAP TO THE METER PIT AND SHALL BE 2" DR9 HDPE PLASTIC PIPE (ASTM 2737) WITH TRACER WIRE. 3. 6-INCH SANITARY SEWER SERVICE SHALL BE PVC (SDR 35) @ 1.0% AS SPECIFIED BY THE SOUTH FORT COLLINS SANITATION DISTRICT. 4. ALL CLEANOUTS SHALL BE TRAFFIC RATED CLEANOUTS. 5. RCP STORM PIPES SHALL BE CLASS III AND BE INSTALLED AND BEDDED PER CITY OF FORT COLLINS STANDARDS. PLASTIC STORM DRAIN PIPES AND UNDERDRAINS SHALL BE HDPE SEWER PIPE OR PVC SEWER PIPE AS NOTED. PLASTIC PIPE BEDDING SHALL BE PER SANITARY SEWER BEDDING DETAIL. ALL STORM SEWER SHALL BE INSPECTED BY THE CITY OF FORT COLLINS. 6. ONSITE IMPROVEMENTS ARE TO BE PRIVATELY OWNED AND MAINTAINED BY THE PROPERTY OWNER. 7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE DONE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8. SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES IN THE BUFFER ZONE. All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. Mr. Terry Farrill, P.E., District Engineer Date Mr. Michael D. DiTullio, Manager Date FORT COLLINS - LOVELAND LEGEND EXISTING FLOODPLAIN PROPOSED FLOODPLAIN EROSION BUFFER PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR VEHICLE TRACKING CONTROL PAD SILT FENCE WATTLE CONCRETE WASHOUT AREA STABILIZED STAGING AREA INLET PROTECTION ROCK CHECK DAM EROSION CONTROL BLANKET 0 SCALE: 1" = 80' 80 40 80 160 OVERALL GRADING & EROSION CONTROL PLAN GR-1 09 of 21 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design LEGEND EXISTING FLOODPLAIN PROPOSED FLOODPLAIN EROSION BUFFER NATURAL RESOURCES BUFFER PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED FLOW DIRECTION 0 SCALE: 1" = 30' 30 15 30 60 GRADING PLAN GR-2 10 of 21 MATCH LINE - SEE SHEET GR-4 MATCH LINE - SEE SHEET GR-3 GR-2 GR-5 GR-6 GR-7 GR-3 GR-4 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN BASEBALL FIELD CREEK PLAY AREA LEGEND EXISTING FLOODPLAIN PROPOSED FLOODPLAIN EROSION BUFFER NATURAL RESOURCES BUFFER PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED FLOW DIRECTION 11 of 21 MATCH LINE - SEE SHEET GR-6 MATCH LINE - SEE SHEET GR-4 GR-2 GR-5 GR-6 GR-7 GR-3 GR-4 MATCH LINE - SEE SHEET GR-2 GRADING PLAN GR-3 0 SCALE: 1" = 30' 30 15 30 60 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design BMX TRACK (TO BE DESIGNED BY OTHERS) BASEBALL FIELD RESTROOM FF=4903.20 LEGEND EXISTING FLOODPLAIN PROPOSED FLOODPLAIN EROSION BUFFER NATURAL RESOURCES BUFFER PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED FLOW DIRECTION 12 of 21 MATCH LINE - SEE SHEET GR-7 GR-2 GR-5 GR-6 GR-7 GR-3 GR-4 MATCH LINE - SEE SHEET GR-3 GRADING PLAN GR-4 0 SCALE: 1" = 30' 30 15 30 60 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates LEGEND EXISTING FLOODPLAIN PROPOSED FLOODPLAIN EROSION BUFFER NATURAL RESOURCES BUFFER PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED FLOW DIRECTION 13 of 21 MATCH LINE - SEE SHEET GR-6 GR-2 GR-5 GR-6 GR-7 GR-3 GR-4 MATCH LINE - SEE SHEET GR-2 GRADING PLAN GR-5 0 SCALE: 1" = 30' 30 15 30 60 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN PLAYGROUND RESTROOM FF=4902.00 PLAYGROUND BARN STRUCTURE FF=4902.50 PLAYGROUND LEGEND EXISTING FLOODPLAIN PROPOSED FLOODPLAIN EROSION BUFFER NATURAL RESOURCES BUFFER PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED FLOW DIRECTION 14 of 21 MATCH LINE - SEE SHEET GR-7 GR-2 GR-5 GR-6 GR-7 GR-3 GR-4 MATCH LINE - SEE SHEET GR-5 MATCH LINE - SEE SHEET GR-3 GRADING PLAN GR-6 0 SCALE: 1" = 30' 30 15 30 60 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. BMX TRACK (TO BE DESIGNED BY OTHERS) DOG PARK EXISTING IRRIGATION & DETENTION POND LEGEND EXISTING FLOODPLAIN PROPOSED FLOODPLAIN EROSION BUFFER NATURAL RESOURCES BUFFER PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED FLOW DIRECTION 15 of 21 GR-2 GR-5 GR-6 GR-7 GR-3 GR-4 MATCH LINE - SEE SHEET GR-6 MATCH LINE - SEE SHEET GR-4 GRADING PLAN GR-7 0 SCALE: 1" = 30' 30 15 30 60 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates SECP PARK ENTRANCE 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 4905 4910 4915 4920 4905 4910 4915 4920 0 SCALE: 1" = 30' 30 15 30 60 ZIEGLER RIGHT TURN LANE PLAN & PROFILE PP - 1 16 of 21 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan x x x x x x x x x x x x x x x x x x x x x x x x x x Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer SABER CAT DRIVE 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 4905 4910 4915 4920 4905 4910 4915 4920 0 SCALE: 1" = 30' 30 15 30 60 ZIEGLER RIGHT TURN LANE PLAN & PROFILE PP - 2 17 of 21 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan x x x x x x x x x x x x x x x x x x x x x x x x x x Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 4890 4895 4900 4890 4895 4900 4890 4895 4900 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 4890 4895 4900 0 SCALE: 1" = 30' 30 15 30 60 LADY MOON ON STREET PARKING PLAN & PROFILE PP - 3 18 of 21 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan x x x x x x x x x x x x x x x x x x x x x x x x x x Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED DRAINAGE BASIN MAJOR STORM RUNOFF COEFFICIENT DRAINAGE BASIN AREA, ACRES DRAINAGE BASIN ID LEGEND PROPOSED DIRECTION OF OVERLAND FLOW DESIGN POINT EXISTING FLOODPLAIN PROPOSED FLOODPLAIN EROSION BUFFER PROPOSED STORM PIPE Š 0 SCALE: 1" = 80' 80 40 80 160 DRAINAGE PLAN DRN-1 19 of 21 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR LEGEND EXISTING FLOODPLAIN PROPOSED FLOODPLAIN EROSION BUFFER PROPOSED BFE AND ELEVATION 0 SCALE: 1" = 80' 80 40 80 160 FLOODPLAIN PLAN FP-1 20 of 21 Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN Drawing Name: 09.02.2015 Project Development Plan CONSTRUCTION DETAILS DT-1 21 of 21 FRENCH DRAIN TYPICAL SECTION N.T.S. CHANNEL W/ ROCK WALL SLOPE/EMBANKMENT PROTECTION TYPICAL SECTION N.T.S. PERMEABLE INTERLOCKING CONCRETE PAVER SECTION N.T.S. Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN Drawing Name: 09.02.2015 Project Development Plan SNOUT DETAIL N.T.S. Drawing Name: 09.02.2015 Project Development Plan tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN Drawing Name: 09.02.2015 Project Development Plan NOTES 1. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE DONE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 4' CONCRETE PAN FLOWLINE PROFILE WEST FLOWLINE PROFILE Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN Drawing Name: 09.02.2015 Project Development Plan NOTES 1. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE DONE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. RIGHT TURN LANE FLOWLINE PROFILE Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN Drawing Name: 09.02.2015 Project Development Plan NOTES 1. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE DONE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. RIGHT TURN LANE FLOWLINE PROFILE 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN Drawing Name: 09.02.2015 Project Development Plan 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN Drawing Name: 09.02.2015 Project Development Plan Drawing Name: 09.02.2015 Project Development Plan 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN Drawing Name: 09.02.2015 Project Development Plan Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN Drawing Name: 09.02.2015 Project Development Plan Drawing Name: 09.02.2015 Project Development Plan Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN Drawing Name: 09.02.2015 Project Development Plan NOTES 1. ALL SLOPES STEEPER THAN 4:1 SHALL RECEIVE EROSION CONTROL BLANKET FOR SLOPE PROTECTION. THIS INCLUDES ALL SLOPES WITHIN THE CHANNEL GRADING LIMITS. EROSION CONTROL BLANKET SHALL BE COIR MAT 40 OR APPROVED EQUAL. WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN Drawing Name: 09.02.2015 Project Development Plan Mr. Michael D. DiTullio, Manager Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN Drawing Name: 09.02.2015 Project Development Plan Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN Drawing Name: 09.02.2015 Project Development Plan SOUTH FORT COLLINS SANITATION DISTRICT Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN Drawing Name: 09.02.2015 Project Development Plan Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN Drawing Name: 09.02.2015 Project Development Plan Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN Drawing Name: 09.02.2015 Project Development Plan Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN Drawing Name: 09.02.2015 Project Development Plan EXISTING UTILITY POLE EXISTING GUY WIRE PROPOSED GAS EXISTING ELECTRIC LINE PROPOSED ELECTRIC LINE EXISTING TELEPHONE LINE EXISTING FIRE HYDRANT PROPOSED FIRE HYDRANT EXISTING WATER VALVE PROPOSED SANITARY SEWER PROPOSED WATER LINE & VALVE EXISTING CONCRETE EXISTING FLOWLINE, CURB & GUTTER PROPOSED FLOWLINE, CURB & GUTTER PROPOSED FENCE EXISTING OVERHEAD UTILITY EXISTING STORM SEWER INLET PROPOSED STADIUM LIGHT EXISTING STREET LIGHT EXISTING FIBER OPTIC LINE EXISTING OVERHEAD ELECTRIC LINE EXISTING OVERHEAD TELEPHONE LINE PROPOSED OVERHEAD ELECTRIC LINE PROPOSED FIBER OPTIC LINE PROPOSED OVERHEAD TELEPHONE LINE EXISTING FENCE PROPOSED OVERHEAD UTILITY EXISTING CABLE TV PROPOSED CABLE TV EXISTING TREE EXISTING PROPERTY LINE CIVIL interwest consulting group 1218 W Ash St Suite C Windsor, Colorado 80524 Ph. 970.460.1091 Contact: Skylar Brower PROJECT MANAGER / LANDSCAPE ARCHITECT CIVITAS 1200 Bannock St Denver, Colorado 80204 Ph. 303.571.0053 x133 Contact: Robin Rooney Norcross EG EXISTING GRADE EL ELEVATION EX EXISTING FES FLARED END SECTION FL FLOWLINE GB GRADE BREAK GV GATE VALVE HP HIGH POINT RD ROOF DRAIN RT RIGHT SAN SANITARY SEWER STA STATION SDMH STORM DRAIN MANHOLE TB THRUST BLOCK TW TOP OF WALL TYP TYPICAL UE UTILITY EASEMENT SITE All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. Mr. Terry Farrill, P.E., District Engineer Date Mr. Michael D. DiTullio, Manager Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT Sheet No. Description of Sheets INDEX OF SHEETS COVER SHEET OVERALL UTILITY PLAN UTILITY PLAN OVERALL GRADING & EROSION CONTROL PLAN GRADING PLAN ZIEGLER RIGHT TURN LANE PLAN & PROFILE LADY MOON PARKING PLAN & PROFILE DRAINAGE PLAN FLOODPLAIN PLAN CONSTRUCTION DETAILS 1 2 3 - 8 9 10 - 15 16 - 17 18 19 20 21 ........................................... ........................................... ........................................... ........................................... ........................................... ........................................... ........................................... ........................................... ........................................... ........................................... INDEMNIFICATION STATEMENT: THESE PLANS HAVE BEEN REVIEWED BY THE CITY OF FORT COLLINS FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BY THE REVIEWING DEPARTMENT, THE CITY OF FORT COLLINS ENGINEER, OR THE CITY OF FORT COLLINS FOR ACCURACY AND CORRECTNESS OF THE CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT QUANTITIES OF ITEMS ON THE PLANS ARE THE FINAL QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE CITY OF FORT COLLINS FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE CONSTRUCTION PHASE. Utility Plans For: SOUTHEAST COMMUNITY PARK Located In The Southwest Quarter of Section 4, T-6-N, R-68-W Of The 6th PM City Of Fort Collins, Larimer County, Colorado SEPTEMBER 2015 PROJECT DATUM: NGVD29 UNADJUSTED (OLD CITY OF FORT COLLINS DATUM) CITY OF FORT COLLINS BENCHMARK #2-03 SOUTH SIDE OF KECHTER ROAD APPROXIMATELY 0.6 MILES WEST OF STRAUSS CABIN ROAD (C.R. 7) ON THE EAST END OF THE SOUTH PARAPET WALL OF A BRIDGE OVER THE DIXON CANYON LATERAL. ELEV=4994.95 CITY OF FORT COLLINS BENCHMARK # 3-02 NORTHEAST CORNER OF THE INTERSECTION OF KECHTER ROAD AND ZIEGLER ROAD ON THE NORTHWEST CORNER OF A CONTROL GATE TO AN IRRIGATION STRUCTURE. ELEV=4915.41 NOTE: IF NAVD88 DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NAVD88=NGVD29 UNADJUSTED + 3.19' Sheet CV UT-1 UT-2 - UT-7 GR-1 GR-2 - GR-7 PP-1 - PP-2 PP-3 DRN FP DT PROPOSED HANDICAP RAMP PROPOSED SANITARY SEWER SERVICE W/ CLEANOUT PRELIMINARY NOT FOR CONSTRUCTION Stamp: Checked: Drawn: CVT Proj. #: SOUTHEAST COMMUNITY PARK 05.12.2015 Project Development Plan Issue Record: Revisions: Consultants: Landscape Architect 3350 Kechter Road, Fort Collins CO, 80528 1200 Bannock St. Denver, CO 80204 Tel. 303 571.0053 Fax 303 425.0438 Ripley Design Inc. (970) 224-5828 970-484-0117 RB+B Architects, Inc. Architect Civil Engineer Interwest Design Group (970) 674-3300 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ 2-13-0010 Mechanical Engineer Abrahamson Engineering, Inc. 970-221-2569 Lighting Design Clanton & Associates 303-530-7229 Irrigation Design Hines Inc 970-282-1800 PROJECT DEVELOPMENT PLAN Drawing Name: 09.02.2015 Project Development Plan