HomeMy WebLinkAboutSOUTHEAST FORT COLLINS COMMUNITY PARK - PDP - PDP140014 - SUBMITTAL DOCUMENTS - ROUND 1 - CORRESPONDENCE-CONCEPTUAL REVIEWland planning landscape architecture urban design entitlement
August 19, 2014
Clark Mapes
City of Fort Collins
281 N. College
Fort Collins, CO 80522
Re: Southeast Fort Collins Community Park
Description of project: This is a request to develop a new park at the northeast corner of Kechter Road
and Ziegler Road (Parcel # 86040-00-932). The park may contain areas for sports fields, baseball diamonds,
trails, restrooms, a community garden and a dog park over the 53.7 acre site. The parcel is located in the
Low Density Mixed-Use Neighborhood (LMN) zone district. The project is subject to Administrative (Type I)
review.
If have any questions regarding the responses in red contact Stephanie Van Dyken with Ripley Design Inc.
For responses in blue please contact Mike Oberlander at Interwest Engineering
Comment Summary:
Department: Water-Wastewater Engineering
Contact: Roger Buffington, 970-221-6854, rbuffington@fcgov.com
1. Water and wastewater services for this site are provided by the Fort Collins-Loveland Water District and
the South Fort Collins Sanitation District. The Districts can be contacted at (970) 226-3104.
Response: Acknowledged.
Department: Traffic Operations
Contact: Martina Wilkinson, 970-221-6887, mwilkinson@fcgov.com
1. Traffic operations (and Transportatio Planning) has been significantly involved with the proposed park for
some time. In fact, the TIS is already scoped and is underway. Further discussions are anticipated once
the TIS is submitted and reviewed.
Response: A TIS has been submitted with this review.
Department: Stormwater Engineering
Contact: Mark Taylor, mtaylor@fcgov.com
1. This property is bisected from west to east by the City-regulatory McClelland’s Creek 100-year floodway
and the proposed project must satisfy all safety requirements of Chapter 10 of City Municipal Code. A
City Flood Risk Map is attached.
Southeast Community Park PDP – Conceptual Review Responses
August 20, 2014
Page 2 of 7
Response: Acknowledged.
2. It doesn’t appear that any buildings are proposed within the floodway. If a building is wanted,
construction of an accessory structure is allowed as long as the lowest finished floor of the building, and
all duct work, heating, ventilation, electrical systems, etc. are elevated 18-inches above the Base Flood
Elevation (BFE). This elevation is known as the Regulatory Flood Protection Elevation (RFPE). RFPE =
BFE + 18-inches.
Response: Acknowledged.
3. Buildings and non-structural development (fencing, detention ponds, hard surface paths, trails, walkways,
vegetation, etc.) are allowed in the floodway as long as a floodway evaluation is prepared by a
professional engineer, licensed in the State of Colorado, proving that the development will not cause a
rise in the BFE or rise in the floodway boundary.
Response: Acknowledged.
4. Fences must be designed to breakaway, and be cabled together so as to not float downstream. An
alternative would be to construct a fence designed to allow the passage of water by use of a flap or
opening in the areas at or below the BFE sufficient to allow floodwater to pass freely.
Response: Acknowledged.
5. All bridges in the floodway must be designed to breakaway, and be cabled in such a way so as to not
float downstream; or have the abutments located outside of the floodway boundaries and be able to
pass all floodwater freely below the bridge span.
Response: Acknowledged.
6. Any construction activities in the 100-year floodway (e.g. building, fencing, detention ponds, hard surface
paths, trails, walkways, vegetation, etc. etc.), must be preceded by an approved floodplain use permit,
the appropriate permit application fees, and approved plans and a No-Rise Certification. The No-Rise
Certification must be prepared by a professional engineer licensed in the State of Colorado. The permit
and certification forms can be obtained at
http://www.fcgov.com/utilities/what-we-do/stormwater/flooding/forms-documents.
Response: Acknowledged.
7. Development review checklists for floodplain requirements can be obtained at
http://www.fcgov.com/utilities/what-we-do/stormwater/flooding/forms-documents. Please utilize these
documents when preparing your plans for submittal. You can contact Shane Boyle of Stormwater Master
Planning at sboyle@fcgov.com for floodplain CAD line work as required per the floodplain development
review check list.
Response: Acknowledged.
8. Please contact Mark Taylor, 970.416.2494, mtaylor@fcgov.com with any questions or comments.
Southeast Community Park PDP – Conceptual Review Responses
August 20, 2014
Page 3 of 7
Response: Acknowledged.
9. A drainage report, erosion control report, and construction plans are required and they must be prepared
by a Professional Engineer registered in Colorado. The drainage report must address the four-step
process for selecting structural BMPs. Standard operating procedures (SOPs) for all onsite drainage
facilities need to be prepared by the drainage engineer and there is a final site inspection required when
the project is complete and the maintenance is handed over to an HOA or another maintenance
organization. The erosion control report requirements are in the Fort Collins Stormwater Manual, Section
1.3.3, Volume 3, Chapter 7 of the Fort Collins Amendments. If you need clarification concerning this
section, please contact the Erosion Control Inspector, Jesse Schlam at 224-6015 or jschlam@fcgov.com.
Response: Acknowledged. Feel free to contact Mike Oberlander if you have questions.
10. In the McClellands drainage basin onsite detention is required with a 0.2 cfs/ac release rate for the 10
year storm and a 0.5 cfs/ac release rate for the 100 year storm.
Response: Acknowledged.
11. Fifty percent of the site runoff is required to be treated using the standard water quality treatment as
described in the Fort Collins Stormwater Manual, Volume 3 – Best Management Practices (BMPs).
(http://www.fcgov.com/utilities/business/builders-and-developers/development-forms-guidelines-regulati
ons/stormwater-criteria) Extended detention is the usual method selected for water quality treatment;
however the use of any of the BMPs is encouraged.
Response: Acknowledged.
12. Low Impact Development (LID) requirements are now required when the impervious area is increased or
a site is required to be brought into compliance with the Land Use Code. These require a higher degree
of water quality treatment for 50% of the new impervious area and 25% of new paved areas must be
pervious. Please contact Basil Hamdan at 224-6035 or bhamdan@fcgov.com for more information.
There is also more information on the EPA web site at: http://water.epa.gov/polwaste/green/bbfs.cfm?
goback=.gde_4605732_member_219392996.
LID design information can be found on the City’s web site at:
http://www.fcgov.com/utilities/business/builders-and-developers/development-forms-guidelines-regulatio
ns/stormwater-criteria.
Response: Due to the nature of this project, we are requesting a variance for this requirement. There will be minimal hardscape
added to the site and larger than normal open space and natural areas. A long linear water quality trench will be used along the
low side of all parking lots.
13. The outfall for the site is McClellands creek. Any detention outfall need to be piped or channeled to the
low flow channel of the creek.
Response: Acknowledged.
14. The city wide Stormwater development fee (PIF) is $7,817/acre ($0.1795 sq.-ft.) for new impervious area
over 350 sq.-ft., and there is a $1,045.00/acre ($0.024/sq.-ft.) review fee. No fee is charged for existing
impervious area. These fees are to be paid at the time each building permit is issued. Information on
fees can be found on the City’s web site at
http://www.fcgov.com/utilities/business/builders-and-developers/plant-investment-development-fees or
contact Jean Pakech at 221- 6375 for questions on fees. There is also an erosion control escrow
required before the Development Construction permit is issued. The amount of the escrow is
Southeast Community Park PDP – Conceptual Review Responses
August 20, 2014
Page 4 of 7
determined by the design engineer, and is based on the site disturbance area, cost of the measures, or
a minimum amount in accordance with the Fort Collins Stormwater Manual.
Response: Acknowledged.
15. The design of this site must conform to the drainage basin design of the McClellands Creek Master
Drainage Plan as well the Fort Collins Stormwater Criteria Manual.
Response: Acknowledged.
Department: Fire Authority
Contact: Jim Lynxwiler, 970-416-2869, jlynxwiler@poudre-fire.org
1. FIRE LANES
Fire access to the site will be needed. Fire lane standards are provided for your reference. At this time,
it does not appear fire lane standards are being met with regard to apparatus turnaround requirements.
IFC 503.1.1: Fire Lanes shall be provided to within 150' of all portions of the building, as measured by an
approved route around the exterior of the building. When fire lanes cannot be provided, the fire code
official is authorized to increase the dimension of 150 feet if the building is equipped throughout with an
approved, automatic fire-sprinkler system.
FIRE LANE SPECIFICATIONS
A fire lane plan shall be submitted for approval prior to installation. In addition to the design criteria
already contained in relevant standards and policies, any new fire lane must meet the following general
requirements:
> Shall be designated on the plat as an Emergency Access Easement.
> Maintain the required 20 foot minimum unobstructed width & 14 foot minimum overhead clearance.
> Be designed as a flat, hard, all-weather driving surface capable of supporting 40 tons.
> Dead-end fire access roads in excess of 150 feet in length shall be provided with an approved area for
turning around fire apparatus.
> The required turning radii of a fire apparatus access road shall be a minimum of 25 feet inside and 50
feet outside. Turning radii shall be detailed on submitted plans.
> Be visible by painting and/or signage, and maintained unobstructed at all times.
International Fire Code 503.2.3, 503.2.4, 503.2.5, 503.3, 503.4 and Appendix D; FCLUC 3.6.2(B)2006 and
Local Amendments.
Response: The turn-around at the playground has been flipped to provide closer access to the restroom building. A roll over curb
and gate have been added at the end of the southwest parking lot.
Department: Environmental Planning
Contact: Lindsay Ex, 970-224-6143, lex@fcgov.com
1. An Ecological Characterization Study is required by Section 3.4.1 (D)(1) as the site is within 500 feet of a
known natural habitat (McClellands Creek). Please note the buffer zone standard of 100' for this feature,
as identified in Section 3.4.1(E) of the Land Use Code, as you proceed with your site design process.
Southeast Community Park PDP – Conceptual Review Responses
August 20, 2014
Page 5 of 7
Please note that the Ecological Characterization Study is due a minimum of 10 days prior to the PDP
submittal.
Response: Acknowledged. The ECS has been submitted.
2. Within the buffer zone, according to Article 3.4.1(E)(1)(g), the City has the ability to determine if the
existing landscaping within the buffer zone is incompatible with the purposes of the buffer zone. Please
ensure that your ECS discusses the existing vegetation and identifies potential restoration options and/or
analyzes how the proposed plantings in the proposed park meet City standards. If it is determined to be
insufficient, then restoration and mitigation measures will be required.
Response: Acknowledged.
3. With respect to lighting, the City of Fort Collins Land Use Code, in Article 3.2.4(D)(6) requires that "natural
areas and natural features shall be protected from light spillage from off site sources." Thus, lighting from
the parking areas or other site amenities shall not spill over to the buffer areas.
Response: Acknowledged. There will be a more detailed lighting plan submitted shortly.
4. With respect to landscaping and design, the City of Fort Collins Land Use Code, in Article 3.2.1 (E)(2)(3),
requires that you use native plants and grasses in your landscaping or re landscaping and reduce
bluegrass lawns as much as possible.
Response: Acknowledged; however, since this is a park there will be substantial areas of turf grass.
5. The applicant should make note of Article 3.2.1(C) that requires developments to submit plans that "...(4)
protects significant trees, natural systems, and habitat". Note that a significant tree is defined as a tree
having DBH (Diameter at Breast Height) of six inches or more. As several of the trees within this site may
have a DBH of greater than six inches, a review of the trees shall be conducted with Tim Buchanan, City
Forester (221 6361) to determine the status of the existing trees and any mitigation requirements that
could result from the proposed development.
Response: Site visits with Tim have been completed. We have submitted the tree mitigation plan and Tim will be removing the
trees that are unsafe.
Department: Engineering Development Review
Contact: Sheri Langenberger, 970-221-6573, slangenberger@fcgov.com
1. Larimer County Road Impact Fees and Street Oversizing Fees are due at the time of building permit.
Please contact Matt Baker at 224-6108 if you have any questions.
Response: Acknowledged.
2. The City's Transportation Development Review Fee (TDRF) is due at the time of submittal. For additional
information on these fees, please see: http://www.fcgov.com/engineering/dev-review.php
Response: Acknowledged.
3. Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets, sidewalks,
curbs and gutters, destroyed, damaged or removed due to construction of this project, shall be replaced
or restored to City of Fort Collins standards at the Developer's expense prior to the acceptance of
completed improvements and/or prior to the issuance of the first Certificate of Occupancy.
Response: Acknowledged.
4. Please contact the City's Traffic Engineer, Martina Wilkinson (221-6887) to schedule a scoping meeting
and determine if a traffic study is needed for this project. In addition, please contact Transportation
Planning for their requirements as well.
Response: Acknowledged. Matt Delich has completed this.
Southeast Community Park PDP – Conceptual Review Responses
August 20, 2014
Page 6 of 7
5. Any public improvements must be designed and built in accordance with the Larimer County Urban Area
Street Standards (LCUASS). This includes access spacing. They are available online at:
http://www.larimer.org/engineering/GMARdStds/UrbanSt.htm
Response: Acknowledged.
6. This project is responsible for dedicating any right-of-way and easement alignments that are necessary
for this project.
Response: Acknowledged.
7. Utility plans will be required.
Response: Acknowledged and submitted.
8. A Development Construction Permit (DCP) or excavation permit (permit type depends on the value of the
public infrastructure work) will need to be obtained prior to starting any work on the site.
Response: Acknowledged.
9. LCUASS parking setbacks (Figure 19-6) apply and will need to be followed depending on parking
design.
Response: Acknowledged.
Department: Electric Engineering
Contact: Jim Spaulding, 970-416-2772, jspaulding@fcgov.com
1. Please contact Light & Power Electrical Engineering for electrical construction coordination and/or any
development questions at 221-6700.
Response: Acknowledged.
Planning Services
Contact: Clark Mapes, 970-221-6225, cmapes@fcgov.com
1. At the west parking lot/restroom area, it looks like walkways should connect to the street. Please consider
the most user-friendly connections in this regard - perhaps one that simply extends the walk on the south
side of the parking; and one along the north side of the entry drive, detached from the drive.
Response: A sidewalk follows the entry drive into the site. This way berms can be provided to screen the parking lot.
2. Parking lot perimeter screening will be required along the edges of parking lots. This can be shrub beds
and low fences or walls. It is understood that this is probably a detail to be developed.
Response: Berms have been provided.
3. Lighting spillover limits and requirements are found in Land Use Code Section 3.2.4(D). The salient
standard appears to be a limit of .1 footcandle 20 feet beyond the property line as a direct result of on-site
lighting.
Response: A photometric plan has been submitted.
4. As noted in previous emails, a neighborhood meeting is not required but even if one was required, the
project has already exceeded any typical requirements.
Response: Three neighborhood meetings were held.
5. The proposed development project is subject to a Type 1 review and public hearing, the decision maker
for Type 1 hearings is an Administrative Hearing Officer. The applicant for this development request is
not required to hold a neighborhood meeting for a Type 1 hearing, but if you would like to have one to
Southeast Community Park PDP – Conceptual Review Responses
August 20, 2014
Page 7 of 7
notify your neighbors of the proposal, please let me know and I can help you in setting a date, time and
location for a meeting. Neighborhood Meetings are a great way to get public feedback and avoid
potential hiccups that may occur later in the review process.
Response: Acknowledged.
6. Please see the Development Review Guide at www.fcgov.com/drg. This online guide features a color
coded flowchart with comprehensive, easy to read information on each step in the process. This guide
includes links to just about every resource you need during development review.
Response: Acknowledged.
7. This development proposal will be subject to all applicable standards of the Fort Collins Land Use Code
(LUC), including Article 3 General Development Standards. The entire LUC is available for your review on
the web at http://www.colocode.com/ftcollins/landuse/begin.htm.
Response: Acknowledged.
8. If this proposal is unable to satisfy any of the requirements set forth in the LUC, a Modification of Standard
Request will need to be submitted with your formal development proposal. Please see Section 2.8.2 of
the LUC for more information on criteria to apply for a Modification of Standard.
Response: Acknowledged.
9. Please see the Submittal Requirements and Checklist at:
http://www.fcgov.com/developmentreview/applications.php.
Response: Acknowledged.
10. The request will be subject to the Development Review Fee Schedule that is available in the Community
Development and Neighborhood Services office. The fees are due at the time of submittal of the required
documents for the appropriate development review process by City staff and affected outside reviewing
agencies. Also, the required Transportation Development Review Fee must be paid at time of submittal.
Response: Acknowledged.
11. When you are ready to submit your formal plans, please make an appointment with Community
Development and Neighborhood Services at (970)221-6750.
Response: Acknowledged.