Loading...
HomeMy WebLinkAboutBUCKINGHAM PLACE, SECOND FILING - PDP/FDP - FDP150001 - SUBMITTAL DOCUMENTS - ROUND 2 - UTILITY PLANS (4)NO. DATE BY REVISION 1 2 3 4 5 6 DESIGNED: DRAWN: CHECKED: PROJECT NO.: DATE: PRELIMINARY NOT FOR CONSTRUCTION SHEET: OF 7/8/2015 45-104 FORT COLLINS, COLORADO BUCKINGHAM PLACE SECOND FILING C9 7 APPROV. 908 Laporte Avenue Fort Collins, CO 80521 (970) 219-2834 ENGINEERING PEX BG DD BG BOW - BACK OF WALK BM - BENCHMARK C&G - CURB AND GUTTER CL - CENTERLINE CMP - CORRUGATED METAL PIPE CO - CLEAN OUT CONC - CONCRETE CONST - CONSTRUCTION DIP - DUCTILE IRON PIPE E - EASTING EA - EMERGENCY ACCESS EXIST - EXISTING ELEV - ELEVATION EOA - EDGE OF ASPHALT EOC - EDGE OF CONCRETE EOLS - EDGE OF LANDSCAPING ESMT - EASEMENT FES - FLARED END SECTION FL - FLOWLINE G - GROUND GV - GATE VALVE HDPE - HIGH DENSITY POLYETHYLENE PIPE VF - VERTICAL FEET HGL - HYDRAULIC GRADE LINE HP - HIGH POINT ID - INNER DIAMETER INV - INVERT IP - INLET PROTECTION LF - LINEAR FEET LOD - LIMIT OF DISTURBANCE LP - LOW POINT LST - LINEAR SEDIMENT TRAP MAX - MAXIMUM MIN - MINIMUM MH - MANHOLE N - NORTHING OD - OUTSIDE DIAMETER P/L - PROPERTY LINE PC - POINT OF CURVATURE PI - POINT OF INTERSECTION PRC - POINT OF REVERSE CURVATURE PROP - PROPOSED PT - POINT OF TANGENCY PVC - POLYVINYL CHLORIDE PIPE PVI - POINT OF VERTICAL INTERSECTION R - RADIUS RCP - REINFORCED CONCRETE PIPE ROW - RIGHT OF WAY SAN - SANITARY SEWER SD - STORM SEWER SBD - STRAW BALE DIKE SF - SILT FENCE STA - STATION SW - STRAW WATTLE S/W - SIDEWALK TB - THURST BLOCK TOC - TOP OF CURB TYP - TYPICAL UDE - UTILITY AND DRAINAGE EASEMENT UDPAE - UTILITY, DRAINAGE AND PUBLIC ACCESS EASEMENT VTP - VEHICAL TRACKING PAD W - WATER W/ - WITH VC - VERTICAL CURVE LEGEND OF ABBREVIATIONS LEGEND OF SYMBOLS - EXISTING These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City Engineer, or the City of Fort Collins for accuracy and corrections of the calculations. Furthermore, the review does not imply that the quantities of the items on the plans are the final quantities required. The review shall not be construed in any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. SF FENCE UNDERGROUND TELEPHONE LINE UNDERGROUND GAS LINE UNDERGROUND ELECTRIC LINE TELECOMMUNICATIONS BOX ELECTRIC VAULT UNDERGROUND WATER LINE UNDERGROUND SEWER LINE SEWER MANHOLE WATER METER WATER VALVE FIRE HYDRANT TREE CONCRETE ASPHALT CONTOUR NO. DATE BY REVISION 1 2 3 4 5 6 DESIGNED: DRAWN: CHECKED: PROJECT NO.: DATE: PRELIMINARY NOT FOR CONSTRUCTION SHEET: OF 7/8/2015 45-104 FORT COLLINS, COLORADO BUCKINGHAM PLACE SECOND FILING C9 7 APPROV. 908 Laporte Avenue Fort Collins, CO 80521 (970) 219-2834 ENGINEERING PEX BG DD BG SBB WATER MAIN WATER SERVICE WATER METER FIRE HYDRANT WATER VALVE SANITARY SEWER MAIN SANITARY SEWER SERVICE MANHOLE FLOWLINE STORM INLET FLARED END SECTION FLOW ARROW CONTOUR SPOT ELEV BASIN LABEL MAJOR BASIN BOUNDARY EXIST DISCHARGE POINT SILT FENCE STRAW BALE BARRIER GRAVEL INLET FILTER VEHICLE TRACKING CONTROL PAD W LEGEND OF SYMBOLS - PROPOSED GENERAL NOTES C2 W WS SA SS City of Fort Collins, Colorado UTILITY PLAN Approval C:\Users\bob\Dropbox\45-104 - Meserlian 3rd Street\DWG\Production\45-104 Cover.dwg, 7/15/2015 12:38:03 PM, 1:1