HomeMy WebLinkAboutBUCKINGHAM PLACE, SECOND FILING - PDP/FDP - FDP150001 - SUBMITTAL DOCUMENTS - ROUND 2 - UTILITY PLANS (4)NO. DATE BY REVISION
1
2
3
4
5
6
DESIGNED:
DRAWN:
CHECKED:
PROJECT NO.:
DATE:
PRELIMINARY
NOT FOR
CONSTRUCTION
SHEET:
OF
7/8/2015
45-104
FORT COLLINS, COLORADO
BUCKINGHAM PLACE SECOND FILING
C9
7
APPROV.
908 Laporte Avenue
Fort Collins, CO 80521
(970) 219-2834
ENGINEERING PEX BG
DD
BG
BOW - BACK OF WALK
BM - BENCHMARK
C&G - CURB AND GUTTER
CL - CENTERLINE
CMP - CORRUGATED METAL PIPE
CO - CLEAN OUT
CONC - CONCRETE
CONST - CONSTRUCTION
DIP - DUCTILE IRON PIPE
E - EASTING
EA - EMERGENCY ACCESS
EXIST - EXISTING
ELEV - ELEVATION
EOA - EDGE OF ASPHALT
EOC - EDGE OF CONCRETE
EOLS - EDGE OF LANDSCAPING
ESMT - EASEMENT
FES - FLARED END SECTION
FL - FLOWLINE
G - GROUND
GV - GATE VALVE
HDPE - HIGH DENSITY POLYETHYLENE PIPE
VF - VERTICAL FEET
HGL - HYDRAULIC GRADE LINE
HP - HIGH POINT
ID - INNER DIAMETER
INV - INVERT
IP - INLET PROTECTION
LF - LINEAR FEET
LOD - LIMIT OF DISTURBANCE
LP - LOW POINT
LST - LINEAR SEDIMENT TRAP
MAX - MAXIMUM
MIN - MINIMUM
MH - MANHOLE
N - NORTHING
OD - OUTSIDE DIAMETER
P/L - PROPERTY LINE
PC - POINT OF CURVATURE
PI - POINT OF INTERSECTION
PRC - POINT OF REVERSE CURVATURE
PROP - PROPOSED
PT - POINT OF TANGENCY
PVC - POLYVINYL CHLORIDE PIPE
PVI - POINT OF VERTICAL INTERSECTION
R - RADIUS
RCP - REINFORCED CONCRETE PIPE
ROW - RIGHT OF WAY
SAN - SANITARY SEWER
SD - STORM SEWER
SBD - STRAW BALE DIKE
SF - SILT FENCE
STA - STATION
SW - STRAW WATTLE
S/W - SIDEWALK
TB - THURST BLOCK
TOC - TOP OF CURB
TYP - TYPICAL
UDE - UTILITY AND DRAINAGE EASEMENT
UDPAE - UTILITY, DRAINAGE AND
PUBLIC ACCESS EASEMENT
VTP - VEHICAL TRACKING PAD
W - WATER
W/ - WITH
VC - VERTICAL CURVE
LEGEND OF ABBREVIATIONS
LEGEND OF SYMBOLS - EXISTING
These plans have been reviewed by the City of Fort Collins for concept
only. The review does not imply responsibility by the reviewing
department, the City Engineer, or the City of Fort Collins for accuracy
and corrections of the calculations. Furthermore, the review does not
imply that the quantities of the items on the plans are the final quantities
required. The review shall not be construed in any reason as
acceptance of financial responsibility by the City of Fort Collins for
additional quantities of items shown that may be required during the
construction phase.
SF
FENCE
UNDERGROUND TELEPHONE LINE
UNDERGROUND GAS LINE
UNDERGROUND ELECTRIC LINE
TELECOMMUNICATIONS BOX
ELECTRIC VAULT
UNDERGROUND WATER LINE
UNDERGROUND SEWER LINE
SEWER MANHOLE
WATER METER
WATER VALVE
FIRE HYDRANT
TREE
CONCRETE
ASPHALT
CONTOUR
NO. DATE BY REVISION
1
2
3
4
5
6
DESIGNED:
DRAWN:
CHECKED:
PROJECT NO.:
DATE:
PRELIMINARY
NOT FOR
CONSTRUCTION
SHEET:
OF
7/8/2015
45-104
FORT COLLINS, COLORADO
BUCKINGHAM PLACE SECOND FILING
C9
7
APPROV.
908 Laporte Avenue
Fort Collins, CO 80521
(970) 219-2834
ENGINEERING PEX BG
DD
BG
SBB
WATER MAIN
WATER SERVICE
WATER METER
FIRE HYDRANT
WATER VALVE
SANITARY SEWER MAIN
SANITARY SEWER SERVICE
MANHOLE
FLOWLINE
STORM INLET
FLARED END SECTION
FLOW ARROW
CONTOUR
SPOT ELEV
BASIN LABEL
MAJOR BASIN BOUNDARY
EXIST DISCHARGE POINT
SILT FENCE
STRAW BALE BARRIER
GRAVEL INLET FILTER
VEHICLE TRACKING
CONTROL PAD
W
LEGEND OF SYMBOLS - PROPOSED
GENERAL NOTES
C2
W
WS
SA
SS
City of Fort Collins, Colorado
UTILITY PLAN Approval
C:\Users\bob\Dropbox\45-104 - Meserlian 3rd Street\DWG\Production\45-104 Cover.dwg, 7/15/2015 12:38:03 PM, 1:1