Loading...
HomeMy WebLinkAboutCENTERPOINT PLAZA (RE-APPLICATION) - PDP - PDP150014 - SUBMITTAL DOCUMENTS - ROUND 1 - CORRESPONDENCE-CONCEPTUAL REVIEWPage 1 of 6 Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov.com RESPONSE TO REVIEW COMMENTS FROM CONCEPTUAL REVIEW MEETING ON 2/9/15 July 15, 2015 From: Patricia Parish, Rocky Mountain Group 2910 Austin Bluffs, Suite 100 Colorado Springs, CO 80918 Re: Centerpoint Plaza To: Planning and Zoning Board Members Description of project: This is a request to approve an previously expired PDP for Centerpoint Plaza (parcel #'s 8720239001 and 8720239002). The previously approved plan allowed for a 2.5 story building that could accommodate any Type I use except for residential in the Employment (E) zone district at the time of approval in 2009. The site is located in the Employment (E) zone district. This proposal will be subject to Administrative (Type I) review. Please see the following summary of comments regarding the project request referenced above. The comments offered informally by staff during the Conceptual Review will assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you have any questions regarding these comments or the next steps in the review process, you may contact the individual commenter or direct your questions through the Project Planner, Clay Frickey, at 970-224-6045 or cfrickey@fcgov.com. Comment Summary: Department: Zoning Contact: Gary Lopez, 970-416-2338, glopez@fcgov.com 1. Please note that there is a new standard for minimum bicycle parking and rack which is found in LUC 3.2.2(C). • This is a design element which we will fit it on to the site in an easy access area. 2. There was mention that the building from as originally proposed will be Page 2 of 6 made smaller. Please include the reduction specifics in the minor amendment. • We propose the building to be reduced from 3-story, 48,000 square feet total, to a 3-story (garden level on first floor), 24,000 square feet total. This will reduce the building footprint to 8,000 square feet per floor with appropriate parking stalls and landscape. Since we believe this is unreasonable to have so little stalls without overflow into the right-of-ways, we will ask for an alternative compliance of additional parking spaces. This will allow free movement within the parcel. 3. In that building reduction please note that the build to standards [LUC 3.5.3(C)(2)] prohibiting parking and driveways between the building and street ROW. • This configuration, setting back the parking from the right-of- way, will be addressed on the site plan. An access easement exists between the property owners within the Private Drive on the east. Otherwise this requirement has been met. 4. Please note new standards for trash enclosures found in LUC 3.2.5. • A new design for the trash enclosure will be shown on the elevations, with the location shown on the Site Plan. Department: Water-Wastewater Engineering Contact: Shane Boyle, 970-221-6339, sboyle@fcgov.com 1. Existing water mains in the area include a 6" main in the driveway to the east of the site, an 8" main in Midpoint Drive, and a 24" main in Timberline Drive. Sanitary sewers in this area include an 8¿ main in the driveway to the east and a 33" main along the railroad to the south. • Noted. 2. There are existing services on site that will need to be located to ensure they do not conflict with the proposed building locations. If these services are not currently in use they will either need to be used by the proposed development or abandoned at the main. • Noted. 3. The water conservation standards for landscape and irrigation will apply. Information on these requirements can be found at: http://www.fcgov.com/standards • A Landscape Plan, addressing water conservation standards for landscape and irrigation, is included with this submittal. 4. Development fees and water rights will be due at building permit. • The development fees will be paid and water rights will be conveyed at building permit stage. Department: Traffic Operations Contact: Martina Wilkinson, 970-221-6887, mwilkinson@fcgov.com 1. The project should plan on making sidewalk connections to Timberline and providing connection on the east side to the north. • We would like to ask that this requirement be reconsidered, as an adequate pedestrian connection is already constructed along Timberline on the west side of the property and a sidewalk along Midpoint Drive. We do Page 3 of 6 not believe an additional point to the east is reasonable, since no other sidewalks would connect with this access and encourages cross-through foot traffic. 2. We'll need to review the original Centerpoint Traffic Impact Study to determine whether it included this use or if an updated study is needed. Contact me to figure this out. • There is an existing Traffic Impact Study on file with the City of Ft. Collins. Department: Stormwater Engineering Contact: Shane Boyle, 970-221-6339, sboyle@fcgov.com 1. A drainage report, erosion control report, and construction plans are required and they must be prepared by a Professional Engineer registered in Colorado. The drainage report must address the four-step process for selecting structural BMPs. Standard operating procedures (SOPs) for all onsite drainage facilities need to be prepared by the drainage engineer and there is a final site inspection required when the project is complete and the maintenance is handed over to an HOA or another maintenance organization. The erosion control report requirements are in the Fort Collins Stormwater Manual, Section 1.3.3, Volume 3, Chapter 7 of the Fort Collins Amendments. If you need clarification concerning this section, please contact the Erosion Control Inspector, Jesse Schlam at 224-6015 or jschlam@fcgov.com. These reports are currently on file with the City of Ft. Collins. They will be updated to meet the current standards. 2. Onsite detention is required for the runoff volume difference between the 100 year developed inflow rate and the 2 year historic release rate. There is an existing detention pond at the southeastern corner of the site. This pond will need to be analyzed to determine if sufficient volume exists to detain for the proposed development or if it will need to be modified to account for the developed runoff. The outfall for this site is the storm sewer pipe at the southern end of the site. Please note, there are new Detention Pond Landscape Guidelines that will need to be net with this development. Onsite detention will be provided onsite. 3. Fifty percent of the site runoff is required to be treated using the standard water quality treatment as described in the Fort Collins Stormwater Manual, Volume 3-Best Management Practices (BMPs). (http://www.fcgov.com/utilities/business/builders-and-developers/development-forms-guideli nes-regulations/stormwater-criteria) Extended detention is the usual method selected for water quality treatment; however the use of any of the BMPs is encouraged. The pond at the southeastern corner of the site can be used to satisfy this requirement provided the necessary volume is available and the outlet structure is modified to account for the additional impervious area. Water quality will be provided onsite for 50% of the run-off. 4. Low Impact Development (LID) requirements are required on all new or redeveloping property which includes sites required to be brought into compliance with the Land Use Code. These require a higher degree of water quality treatment for 50% of the new impervious area and 25% of new paved areas must be pervious. For more information please refer to the City's website where additional information and links can be found at: http://www.fcgov.com/utilities/what-we-do/stormwater/stormwater-quality/low-impact-develo pment LID requirements will be provided for this site and calculations shown on the site plan. 5. The city wide Stormwater development fee (PIF) is $7,817/acre ($0.1795 sq.-ft.) for new impervious area over 350 sq.-ft., and there is a $1,045.00/acre ($0.024/sq.-ft.) review fee. No fee is charged for existing impervious area. These fees are to be paid at the time each building permit is issued. Information on fees can be found on the City's web site at http://www.fcgov.com/utilities/business/builders-and-developers/plant-investment-developme nt-fees or contact Jean Pakech at 221-6375 for questions on fees. There is also an erosion Page 4 of 6 control escrow required before the Development Construction permit is issued. The amount of the escrow is determined by the design engineer, and is based on the site disturbance area, cost of the measures, or a minimum amount in accordance with the Fort Collins Stormwater Manual. The Stormwater Development Fee and the Erosion Control Escrow will paid before the Development Construction Permit is issued. 6. The design of this site must conform to the drainage basin design of the Cache la Poudre River Master Drainageway Plan as well the Fort Collins Stormwater Manual. The design of the site will conform to the drainage basin design standards specified above. Department: Fire Authority Contact: Jim Lynxwiler, 970-416-2869, jlynxwiler@poudre-fire.org 1. FIRE LANE SPECIFICATIONS A fire lane plan shall be submitted for approval prior to installation. In addition to the design criteria already contained in relevant standards and policies, any new fire lane must meet the following general requirements: > Shall be designated on the plat as an Emergency Access Easement. > Maintain the required 20 foot minimum unobstructed width & 14 foot minimum overhead clearance. > Be designed as a flat, hard, all-weather driving surface capable of supporting 40 tons. > Dead-end fire access roads in excess of 150 feet in length shall be provided with an approved area for turning around fire apparatus. > The required turning radii of a fire apparatus access road shall be a minimum of 25 feet inside and 50 feet outside. Turning radii shall be detailed on submitted plans. > Be visible by painting and/or signage, and maintained unobstructed at all times. > Additional access requirements exist for buildings greater than 30' in height. Refer to Appendix D of the 2012 IFC or contact PFA for details. International Fire Code 503.2.3, 503.2.4, 503.2.5, 503.3, 503.4 and Appendix D; FCLUC 3.6.2(B)2006 and Local Amendments. The fire lane specifications will be shown on the site plan. 2. PUBLIC-SAFETY RADIO AMPLIFICATION SYSTEM New buildings require a fire department, emergency communication system evaluation after the core/shell but prior to final build out. For the purposes of this section, fire walls shall not be used to define separate buildings. Where adequate radio coverage cannot be established within a building, public-safety radio amplification systems shall be designed and installed in accordance with criteria established by the Poudre Fire Authority. Poudre Fire Authority Bureau Admin Policy #07-01 The building will be designed and installed with the required fire department emergency communication system and be evaluated prior to final build out. 3. AUTOMATIC FIRE SPRINKLER SYSTEM This building will require an automatic fire sprinkler system under a separate permit. Please contact Assistant Fire Marshal, Joe Jaramillo with any fire sprinkler related questions at 970-416-2868. The building will be designed with an automatic fire sprinkler system with the required separate permit. Department: Environmental Planning Contact: Stephanie Blochowiak, 970-416-2401, sblochowiak@fcgov.com 1. With respect to landscaping and design, the City of Fort Collins Land Use Code, in Article 3.2.1 (E)(2)(3), requires that you use native plants and grasses in your landscaping or re landscaping and reduce bluegrass lawns as much as possible. The landscape plan will show design requirements of the appropriate Article 3.2.1 (E)(2)(3). Page 5 of 6 Department: Engineering Development Review Contact: Sheri Langenberger, 970-221-6573, slangenberger@fcgov.com 1. Larimer County Impact Fees and Street Oversizing Fees are due at the time of building permit. Please contact Matt Baker at 224-6108 if you have any questions. The appropriate Larimer County Road Impact Fees and Street Oversizing Fees will be paid at time of building permit. 2. The City's Transportation Development Review Fee (TDRF) is due at the time of submittal. For additional information on these fees, please see: http://www.fcgov.com/engineering/dev- review.php The City’s Transportation Development Review fee will be paid at time of submittal. 3. Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets, sidewalks, curbs and gutters, destroyed, damaged or removed due to construction of this project, shall be replaced or restored to City of Fort Collins standards at the Developer's expense prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. Damaged curb, gutter and sidewalk will be replaced or restored prior to issuance of Certificate of Occupancy. 4. All public sidewalk, driveways and ramps existing or proposed adjacent or within the site need to meet ADA standards, if they currently do not, they will need to be reconstructed so that they do meet current ADA standards as a part of this project. The existing driveway will need to be evaluated to determine if the slopes and width will meet ADA requirements or if they need to be reconstructed so that they do. An evaluation of existing and proposed ADA sidewalk, driveway and ramp standards will be adhered to and shown on the site plan. 5. Any public improvements must be designed and built in accordance with the Larimer County Urban Area Street Standards (LCUASS). They are available online at: http://www.larimer.org/engineering/GMARdStds/UrbanSt.htm Public improvements will be designed and built in accordance with the Larimer County Urban Area Street Standards. 6. The existing utility plans for this site are expired and new plans will need to be prepared and submitted for review and approval. New utility plans will be prepared and submitted. 7. Utility plans will be required and a an amendment to the existing Development Agreement or a new Development Agreement will need to be entered into and will be recorded once the project is finalized. Utility plans and an amendment to the existing Development Agreement completed and recorded prior to finalization of the project. 8. This project is responsible for dedicating any right-of-way and easements that are necessary for this project. The easements dedicated by plat are still valid and exist. Any changes to the easements can be done by replat or by separate document. No changes to existing easements or rights-of-way are planned for this project. 9. A Development Construction Permit (DCP) will need to be obtained prior to starting any work on public utilities or within City right-of-way or easements. The necessary Development Construction Permit will be obtained prior to starting work in the easements or city ROW. 10. Platte River power authority will need to approve the plans showing work under the power lines and within their easement. Any work in easements or under Platte River Power Authority power lines will be approved prior to commencement. Page 6 of 6 Department: Electric Engineering Contact: Luke Unruh, 9704162724, lunruh@fcgov.com 1. Light and Power has electric facilities surrounding the site that could be utilized to provide three phase power. The best place to tap power will depend on the transformer location and a cost effective route. Noted. 2. Contact Light and Power Engineering to coordinate the transformer and electric meter locations, please show the locations on the utility plans. Locations will be shown on the utility plan for electric meters and transformer locations. 3. Please provide a one line diagram and a C-1 form to Light and Power Engineering. The C-1 form can be found at: http://zeus.fcgov.com/utils-procedures/files/EngWiki/WikiPdfs/C/C-1Form.pdf A one line diagram and a C-1 form will be provided to Light and Power. 4. Development and capacity charges will apply at owner’s expense. Development and capacity charges will be paid by the owner. 5. Please contact Light & Power Engineering if you have any questions at 221-6700. Please reference our policies, development charge processes, and use our fee estimator at http://www.fcgov.com/utilities/business/builders-and-developers Noted. Planning Services Contact: Clay Frickey, 970-224-6045, cfrickey@fcgov.com 1. The proposed building will need to be in compliance with section 3.5.5 of the Land Use Code. Noted. Compatible architecture, convenient services and design features will be addressed on the site plan. The landscape and site design will provide privacy, safe circulation, screening and aesthetics to the site. The use of office/retail will enhance the services offered in that area of town, as well as provide employment to the community. 2. You will need to show how a person can gain access to the trash enclosure without opening the main service gates per section 3.2.5 of the Land Use Code. You can show this on the building elevations or site plan upon submittal. A trash enclosure meeting these standards will be shown on the site plan or building elevations. 3. The proposed development project is subject to a Type 1 review and public hearing, the decision maker for Type 1 hearings is an Administrative Hearing Officer. The applicant for this development request is not required to hold a neighborhood meeting for a Type 1 hearing, but if you would like to have one to notify your neighbors of the proposal, please let me know and I can help you in setting a date, time and location for a meeting. Neighborhood Meetings are a great way to get public feedback and avoid potential hiccups that may occur later in the review process. Noted. 4. Please see the Development Review Guide at www.fcgov.com/drg. This online guide features a color coded flowchart with comprehensive, easy to read information on each step in the process. This guide includes links to just about every resource you need during development review. Noted. 5. This development proposal will be subject to all applicable standards of the Fort Collins Land Use Code (LUC), including Article 3 General Development Standards. The entire LUC is available for your review on the web at http://www.colocode.com/ftcollins/landuse/begin.htm. Noted. 6. If this proposal is unable to satisfy any of the requirements set forth in the LUC, a Modification of Standard Request will need to be submitted with your formal development proposal. Page 7 of 6 Please see Section 2.8.2 of the LUC for more information on criteria to apply for a Modification of Standard. Noted. 7. Please see the Submittal Requirements and Checklist at: http://www.fcgov.com/developmentreview/applications.php. Noted. 8. The request will be subject to the Development Review Fee Schedule that is available in the Community Development and Neighborhood Services office. The fees are due at the time of submittal of the required documents for the appropriate development review process by City staff and affected outside reviewing agencies. Also, the required Transportation Development Review Fee must be paid at time of submittal. All required review fees will be paid at time of submittal. 9. When you are ready to submit your formal plans, please make an appointment with Community Development and Neighborhood Services at (970)221-6750. Noted. Page 8 of 6 Pre-Submittal Meetings for Building Permits Pre-Submittal meetings are offered to assist the designer/builder by assuring, early on in the design, that the new commercial or multi-family projects are on track to complying with all of the adopted City codes and Standards listed below. The proposed project should be in the early to mid-design stage for this meeting to be effective and is typically scheduled after the Current Planning conceptual review meeting. Noted. Applicants of new commercial or multi-family projects are advised to call 970-416-2341 to schedule a pre-submittal meeting. Applicants should be prepared to present site plans, floor plans, and elevations and be able to discuss code issues of occupancy, square footage and type of construction being proposed. Noted. Construction shall comply with the following adopted codes as amended: 20012 International Building Code (IBC) 2012 International Residential Code (IRC) 20012 International Energy Conservation Code (IECC) 2012 International Mechanical Code (IMC) 2012 International Fuel Gas Code (IFGC) 2012 International Plumbing Code (IPC) as amended by the State of Colorado 2014 National Electrical Code (NEC) as amended by the State of Colorado Accessibility: State Law CRS 9-5 & ICC/ANSI A117.1-2009. Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF. Frost Depth: 30 inches. Wind Load: 100- MPH 3 Second Gust Exposure B. Seismic Design: Category B. Climate Zone: Zone 5. Energy Code Use 1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC Chapter 4. 2. Multi-family and Condominiums 3 stories max: 2012 IECC Chapter 4 Residential Provisions. 3. Commercial and Multi-family 4 stories and taller: 2012 IECC Chapter 4 Commercial Provisions. Noted. Fort Collins Green Code Amendments effective starting 2/17/2014. A copy of these requirements can be obtained at the Building Office or contact the above phone number. Noted. City of Fort Collins Building Services Plan Review 970-416-2341