HomeMy WebLinkAboutRAW URTH DESIGNS - PDP - PDP150007 - SUBMITTAL DOCUMENTS - ROUND 1 - SITE PLAN4971
4972
4973
4973
4972
4972
4970
4971
DW REF.
RED CEDAR CIRCLE
35' - 0"
10' - 0"
8' - 0" 6' - 0" 19' - 0" 24' - 0" 19' - 0" 13' - 0" 2' - 0"
5' - 0"
6' - 0"
CONIFER STREET
80' ROW
RED CEDAR CIRCLE 60' ROW
4' SIDEWALK
6' SIDEWALK
20' GATE
20' GATE
PAVED OUTDOOR
STORAGE YARD
DETENTION
POND
ALLEY
LOT 19
BLOCK 3
LOT 20
BLOCK 3
BLDG FOOTPRINT
12,420 SF
A B C D E F
G
1
2
3
62' - 0"
TRUNCATED DOMES
1" WATER SERVICE
RE: CIVIL
6" FIRE LINE
RE: CIVIL
5
PAINTED HANDICAP
SYMBOL
HANDICAP
PARKING SIGN
SEE DETAIL
4" SANITARY SEWER
SERVICE
RE: CIVIL
FDC
CONCRETE RETAINING WALL
RE: CIVIL
SIDEWALK
5' - 0"
4' - 0"
TRUNCATED
6' - 0"
AFG
2' - 0" 18'-0"
DOWN DIRECTIONAL FIXTURE
WITH CUT-OFF LUMINAIRE
(MAY BE SINGLE OR MULTIPLE
HEAD FIXTURE
RE: PHOTOMETRICS
BRONZE ANODIZE LIGHT POLE
FIXTURE - RE: ELECTRICAL PLANS
(4) ANCHORE BOLTS FURNISHED TO
GENERAL CONTRACTOR BYELECTRICAL
CONTRACTOR PER FIXTURE
MANUFACTURER TEMPLATE - VERIFY
#6 BARE COPPER GROUND WIRE - RE:
ELECTRICAL
#4 VERTICALS W/ #4 TIES @ 12" O.C.
CONCRETE BASE PER GENERAL
CONTRACTOR
24" CONCRETE BASE WITH CHAMFER
EDGE
FINISH GRADE
CONDUIT IN & OUT 30" MIN. BELOW
GRADE
2' - 0"
NOTE:
ALL ON SITE LIGHTING SHALL BE GLARE SHIELDED.
NO DIRECT LIGHTING SHALL BE DIRECTED OFF OF
THE PROPERTY LIMITS.
-SEE ELECTRICAL PLANS FOR NO. & LOCATIONS OF
FIXTURE HEADS.
RE: TO SHEET E2P POLE BAE MOUNTING DETAIL
METAL LUG CONNECTION TO POLE
2-3/8" OD SCHEDULE 40
STEEL PIPE
COLOR: MATCH METAL BUILDING
PANEL
FINISH
GRADE
5 TOTAL SPACES
5' - 0 1/2"
3' - 0"
1' - 5 1/2"
EXPANSION JOINT &
SEALANT
CONCRETE PIER
6" DIAMETER STEEL BOLLARD
FILLED WITH CONCRETE
PAINTED "HIGH-VISIBILITY
YELLOW"
0' - 9" 2' - 6" 5' - 0"
0' - 6"0' - 6"0' - 6"
1' - 6"
SLOPE T.O.
CONCRETE
STALL SURFACE
CENTER SIGN WITHIN PARKING
STALL AT INTERIOR END
R7-8
2" DIAMETER METAL PIPE WHERE
WALL-MOUNTING IS NOT PRACTICAL
ABOVE STALL SURFACE
7' - 0" 0' - 6"
0' - 1"
1' - 6"
1' - 0"
R7-201
R78b AT VAN STALLS
PER ANSI SEC. 703
3" WIDE PAINTED STRIPES AT 3'-0" O.C.
INTERNATIONAL ACCESSIBLE
SYMBOL PER ICC/ANSI 117.1-2003
SECTION 703.6.3.1
ACCESSIBLE STALL WITH ACCESS AISLE
8'-0" MIN AT VAN
9' - 0"
19' - 0"
9' - 0"
STANDARD PARKING STALL
9' - 0"
4" WIDE PAINTED
STRIPE (TYP.)
18' - 0"
1. Paved with asphalt, concrete or pavers
2. Designed so that slope, measured in any direction, and
does not exceed a one (I) foot rise to a fifty (50) foot run;
3. Designed so that whenever there is more than a one-half
(1/2) inch change in the elevation of the surface between
a handicapped accessible route and the handicapped
parking space, a ramp shall be provided to connect the
route and the parking space.
3780 East 15th Street, Suite 201 Loveland, Colorado 80538
970.669.8220
E-mail: info@hauserarchitectspc.com HauserArchitectspc.com
SHEET
Hauser Architects, P.C.
1313 BLUE SPRUCE DR, FORT COLLINS, CO 80524
5/29/2015 1:19:00 PM C:\Users\CurtisK\Google Drive\Current PROJECTS\Raw Urth Designs\RevitProjects\Raw Urth.rvt
AMY SASICK
RAW URTH DESIGNS
ARCHITECTURAL SITE DETAILS
A-2
1/2" = 1'-0"
2
PARKING LOT LIGHT DETAIL
1/2" = 1'-0"
5
BIKE RACK DETAIL
1/2" = 1'-0"
4
PIPE BOLLARD TYP.
1/2" = 1'-0"
3
ACCESSIBLE PARKING SIGNAGE1
REVISIONS
Revision 1 Date 1
1/8" = 1'-0"
1
PARKING STALL STRIPING
DOMES
TRUNCATED
DOMES
4
200' - 0"
6' - 0" 36' - 0"
TYP.
9' - 0" 9' - 0"
PARKWAY
8' - 0"
SIDEWALK
5' - 0"
PARKWAY
8' - 0"
BIKE RACK
LANDSCAPE YARD
30' - 0"
LOT LINE 300'
LOT LINE 135'
TRASH TO BE
SCREENED BY
STORAGE YARD
FENCING
LAND USE DATA TABLE
TOTAL
BUILDING FOOTPRINT 12,420 SF 30%
PAVED AREAS
(PARKING, WALKS & DRIVE) 15,610 SF 39%
AREA OF LANDSCAPING 12,737 SF 31%
TOTAL LOT AREA: 40,452 SF
.928650 ACRES
LEGAL DESCRIPTION
LOT 20, BLOCK 3, EVERGREEN PARK REPLAT 1 SITUATED IN THE
NORTHWEST ONE-QUARTER SECTION 1, TOWNSHIP 7 NORTH,
RANGE 69 WEST OF THE SIXTH PRINCIPAL MERIDIAN. CITY OF
FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO.
ZONING: (I) INDUSTRIAL
PARKING SUMMARY
PARKING REQUIRED
.75 PER EMPLOYEE @ 10 EMPLOYEES = 8 SPACES
TOTAL 8 SPACES
TOTAL PROVIDED 9 SPACES
1 HC SPACES REQUIRED
1 HC SPACES
ALL PARKING SPACES ARE STANDARD SIZE SPACES (INCLUDES 1
HANDICAP SPACES AND 5 BYCYCLE SPACES
BUILDING SQ. FT. DATA
MAIN LEVEL
OFFICE (B) OCCUPANCY 2,323 SF
WAREHOUSE (S-2) OCCUPANCY 10,097 SF
SECOND LEVEL
12,420 SF
TOTAL BUILDING SQUARE FOOTAGE 15,405 SF
OFFICE (B) OCCUPANCY 2,293 SF
WAREHOUSE (S-2) OCCUPANCY 692 SF
SQUARE FOOTAGE
SQUARE FOOTAGE 2,985 SF
TYPE V-B CONSTRUCTION (SPRINKLED)
APPLICABLE NOTES FROM THE DEVELOPMENT FINAL PLAN
1. ALL PORTIONS OF THE EXTERIOR WALLS OF THE FIRST STORY OF ALL BUILDINGS
WILL BE LOCATED WITHIN 150' OF ACCESS ROADWAY IN WHICH EMERGENCY FIRE
EQUIPMENT CAN BE MANEUVERED OR THE BUILDINGS WILL BE PROVIDED WITH AN
APPROVED FIRE EXTINGUISHING SYSTEM.
2. REFER TO UTILITIES PLAN FOR LOCATION OF UTILITIES AND DRAINAGE.
3. SIDEWALKS AND RAMPS WILL CONFORM TO CITY STANDARDS.
4. PROPOSED EXTERIOR LIGHTING WILL BE POLE-MOUNTED LUMINARIES AT DRIVES AND
PARKING AREAS. BOTH POLE AND BUILDING MOUNTED FIXTURES WILL FEATURE DOWN-
DIRECTIONAL AND SHARP CUTOFF LUMINARIES. ALL WALL MOUNTED LIGHT FIXTURES
SHALL BE FULLY SHIELDED TO CONCEAL LIGHT SOURCE.
5. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT IS TO BE FULLY
SCREENED FROM PUBLIC VIEW WITH ROOFTOP PARAPET WALLS AND LANDSCAPING.
CONDUITS, METERS, VENTS AND OTHER EQUIPMENT ATTACHED TO THE BUILDING OR
PROTRUDING FROM THE ROOF SHALL BE PAINTED TO MATCH SURROUNDING BUILDING
SURFACES.
6. ALL SIGNAGE TO COMPLY WITH LOCAL SIGN CODE.
7. THE TRASH ENCLOSURES WILL BE MOUNTED ON CONCRETE AND BE CONSTRUCTED
OF MATERIALS TO MATCH THE BUILDINGS. ANY GATES CONSTRUCTED WILL BE OF SOLID
MATERIAL.
8. BIKE RACKS ARE TO BE PERMANENTLY ANCHORED TO CONCRETE AND WILL NOT
INTERFERE WITH PEDESTRIAN WALKWAYS.
9. ALL HANDICAP PARKING SPACES AND RAMPS ARE TO BE VERIFIED WITH CIVIL
ENGINEER FOR GRADING, DRAINAGE, AND ACCESSIBLE ROUTE CONSIDERATIONS.
HANDICAP PARKING SPACES SHOULD SLOPE NO MORE THAN 1:48 IN ANY DIRECTION.
ALL ACCESSIBLE ROUTES SHOULD SLOPE NO MORE THAN 1:20 IN DIRECTION OF
TRAVEL AND NO MORE THAN 1:48 CROSS SLOPE.
10. ALL INTERNAL PEDESTRIAN WALKWAYS SHALL BE DISTINGUISHED FROM DRIVING
SURFACES THROUGH THE USE OF DURABLE LOW-MAINTENANCE SURFACE MATERIALS
SUCH AS SCORED CONCRETE TO ENHANCE PEDESTRIAN SAFETY AND COMFORT AS
WELL AS THE ATTRACTIVENESS OF THE WALKWAYS.
11. ELECTRICAL TRANSFORMERS AND NATURAL GAS EQUIPMENT SHALL BE FULLY
SCREENED FROM PUBLIC VIEW BY A SOLID HEDGE OF PLANT MATERIAL OR AN
ENCLOSURE MEETING THE CLEARANCE SPECIFICATIONS OF LIGHT AND POWER. SUCH
ENCLOSURE MUST MATCH THE PREDOMINATE MATERIALS OF THE BUILDING BEING
SERVED. TRANSFORMERS MUST BE WITHIN TEN FEET OF HARD SURFACE.
12. IN ORDER TO COMPLY WITH OPERATIONAL AND PHYSICAL COMPATIBILITY
STANDARDS, THE OUTDOOR STORAGE OF PRODUCTS OR MATERIALS, INCLUDING TIRE
DISPLAY RACKS OR USED TIRES SHALL BE SCREENED FROM PUBLIC VIEW. IN ADDITION,
VENDING MACHINES SHALL BE PLACED INSIDE BUILDINGS OR BEHIND SCREEN WALLS.
GENERAL NOTES
3780 East 15th Street, Suite 201 Loveland, Colorado 80538
970.669.8220
E-mail: info@hauserarchitectspc.com HauserArchitectspc.com
SHEET
Hauser Architects, P.C.
1313 BLUE SPRUCE DR, FORT COLLINS, CO 80524
5/29/2015 1:18:59 PM C:\Users\CurtisK\Google Drive\Current PROJECTS\Raw Urth Designs\RevitProjects\Raw Urth.rvt
AMY SASICK
RAW URTH DESIGNS
ARCHITECTURAL SITE PLAN
A-1
3/32" = 1'-0"
1
Site Plan
REVISIONS
SHEET INDEX
SHEET
NUMBER SHEET NAME
PDP SET
ARCHITECTURAL PDP
A-1 ARCHITECTURAL SITE PLAN X
A-2 ARCHITECTURAL SITE DETAILS X
A-3 ELEVATIONS X