Loading...
HomeMy WebLinkAboutRAW URTH DESIGNS - PDP - PDP150007 - SUBMITTAL DOCUMENTS - ROUND 1 - SITE PLAN4971 4972 4973 4973 4972 4972 4970 4971 DW REF. RED CEDAR CIRCLE 35' - 0" 10' - 0" 8' - 0" 6' - 0" 19' - 0" 24' - 0" 19' - 0" 13' - 0" 2' - 0" 5' - 0" 6' - 0" CONIFER STREET 80' ROW RED CEDAR CIRCLE 60' ROW 4' SIDEWALK 6' SIDEWALK 20' GATE 20' GATE PAVED OUTDOOR STORAGE YARD DETENTION POND ALLEY LOT 19 BLOCK 3 LOT 20 BLOCK 3 BLDG FOOTPRINT 12,420 SF A B C D E F G 1 2 3 62' - 0" TRUNCATED DOMES 1" WATER SERVICE RE: CIVIL 6" FIRE LINE RE: CIVIL 5 PAINTED HANDICAP SYMBOL HANDICAP PARKING SIGN SEE DETAIL 4" SANITARY SEWER SERVICE RE: CIVIL FDC CONCRETE RETAINING WALL RE: CIVIL SIDEWALK 5' - 0" 4' - 0" TRUNCATED 6' - 0" AFG 2' - 0" 18'-0" DOWN DIRECTIONAL FIXTURE WITH CUT-OFF LUMINAIRE (MAY BE SINGLE OR MULTIPLE HEAD FIXTURE RE: PHOTOMETRICS BRONZE ANODIZE LIGHT POLE FIXTURE - RE: ELECTRICAL PLANS (4) ANCHORE BOLTS FURNISHED TO GENERAL CONTRACTOR BYELECTRICAL CONTRACTOR PER FIXTURE MANUFACTURER TEMPLATE - VERIFY #6 BARE COPPER GROUND WIRE - RE: ELECTRICAL #4 VERTICALS W/ #4 TIES @ 12" O.C. CONCRETE BASE PER GENERAL CONTRACTOR 24" CONCRETE BASE WITH CHAMFER EDGE FINISH GRADE CONDUIT IN & OUT 30" MIN. BELOW GRADE 2' - 0" NOTE: ALL ON SITE LIGHTING SHALL BE GLARE SHIELDED. NO DIRECT LIGHTING SHALL BE DIRECTED OFF OF THE PROPERTY LIMITS. -SEE ELECTRICAL PLANS FOR NO. & LOCATIONS OF FIXTURE HEADS. RE: TO SHEET E2P POLE BAE MOUNTING DETAIL METAL LUG CONNECTION TO POLE 2-3/8" OD SCHEDULE 40 STEEL PIPE COLOR: MATCH METAL BUILDING PANEL FINISH GRADE 5 TOTAL SPACES 5' - 0 1/2" 3' - 0" 1' - 5 1/2" EXPANSION JOINT & SEALANT CONCRETE PIER 6" DIAMETER STEEL BOLLARD FILLED WITH CONCRETE PAINTED "HIGH-VISIBILITY YELLOW" 0' - 9" 2' - 6" 5' - 0" 0' - 6"0' - 6"0' - 6" 1' - 6" SLOPE T.O. CONCRETE STALL SURFACE CENTER SIGN WITHIN PARKING STALL AT INTERIOR END R7-8 2" DIAMETER METAL PIPE WHERE WALL-MOUNTING IS NOT PRACTICAL ABOVE STALL SURFACE 7' - 0" 0' - 6" 0' - 1" 1' - 6" 1' - 0" R7-201 R78b AT VAN STALLS PER ANSI SEC. 703 3" WIDE PAINTED STRIPES AT 3'-0" O.C. INTERNATIONAL ACCESSIBLE SYMBOL PER ICC/ANSI 117.1-2003 SECTION 703.6.3.1 ACCESSIBLE STALL WITH ACCESS AISLE 8'-0" MIN AT VAN 9' - 0" 19' - 0" 9' - 0" STANDARD PARKING STALL 9' - 0" 4" WIDE PAINTED STRIPE (TYP.) 18' - 0" 1. Paved with asphalt, concrete or pavers 2. Designed so that slope, measured in any direction, and does not exceed a one (I) foot rise to a fifty (50) foot run; 3. Designed so that whenever there is more than a one-half (1/2) inch change in the elevation of the surface between a handicapped accessible route and the handicapped parking space, a ramp shall be provided to connect the route and the parking space. 3780 East 15th Street, Suite 201 Loveland, Colorado 80538 970.669.8220 E-mail: info@hauserarchitectspc.com HauserArchitectspc.com SHEET Hauser Architects, P.C. 1313 BLUE SPRUCE DR, FORT COLLINS, CO 80524 5/29/2015 1:19:00 PM C:\Users\CurtisK\Google Drive\Current PROJECTS\Raw Urth Designs\RevitProjects\Raw Urth.rvt AMY SASICK RAW URTH DESIGNS ARCHITECTURAL SITE DETAILS A-2 1/2" = 1'-0" 2 PARKING LOT LIGHT DETAIL 1/2" = 1'-0" 5 BIKE RACK DETAIL 1/2" = 1'-0" 4 PIPE BOLLARD TYP. 1/2" = 1'-0" 3 ACCESSIBLE PARKING SIGNAGE1 REVISIONS Revision 1 Date 1 1/8" = 1'-0" 1 PARKING STALL STRIPING DOMES TRUNCATED DOMES 4 200' - 0" 6' - 0" 36' - 0" TYP. 9' - 0" 9' - 0" PARKWAY 8' - 0" SIDEWALK 5' - 0" PARKWAY 8' - 0" BIKE RACK LANDSCAPE YARD 30' - 0" LOT LINE 300' LOT LINE 135' TRASH TO BE SCREENED BY STORAGE YARD FENCING LAND USE DATA TABLE TOTAL BUILDING FOOTPRINT 12,420 SF 30% PAVED AREAS (PARKING, WALKS & DRIVE) 15,610 SF 39% AREA OF LANDSCAPING 12,737 SF 31% TOTAL LOT AREA: 40,452 SF .928650 ACRES LEGAL DESCRIPTION LOT 20, BLOCK 3, EVERGREEN PARK REPLAT 1 SITUATED IN THE NORTHWEST ONE-QUARTER SECTION 1, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE SIXTH PRINCIPAL MERIDIAN. CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO. ZONING: (I) INDUSTRIAL PARKING SUMMARY PARKING REQUIRED .75 PER EMPLOYEE @ 10 EMPLOYEES = 8 SPACES TOTAL 8 SPACES TOTAL PROVIDED 9 SPACES 1 HC SPACES REQUIRED 1 HC SPACES ALL PARKING SPACES ARE STANDARD SIZE SPACES (INCLUDES 1 HANDICAP SPACES AND 5 BYCYCLE SPACES BUILDING SQ. FT. DATA MAIN LEVEL OFFICE (B) OCCUPANCY 2,323 SF WAREHOUSE (S-2) OCCUPANCY 10,097 SF SECOND LEVEL 12,420 SF TOTAL BUILDING SQUARE FOOTAGE 15,405 SF OFFICE (B) OCCUPANCY 2,293 SF WAREHOUSE (S-2) OCCUPANCY 692 SF SQUARE FOOTAGE SQUARE FOOTAGE 2,985 SF TYPE V-B CONSTRUCTION (SPRINKLED) APPLICABLE NOTES FROM THE DEVELOPMENT FINAL PLAN 1. ALL PORTIONS OF THE EXTERIOR WALLS OF THE FIRST STORY OF ALL BUILDINGS WILL BE LOCATED WITHIN 150' OF ACCESS ROADWAY IN WHICH EMERGENCY FIRE EQUIPMENT CAN BE MANEUVERED OR THE BUILDINGS WILL BE PROVIDED WITH AN APPROVED FIRE EXTINGUISHING SYSTEM. 2. REFER TO UTILITIES PLAN FOR LOCATION OF UTILITIES AND DRAINAGE. 3. SIDEWALKS AND RAMPS WILL CONFORM TO CITY STANDARDS. 4. PROPOSED EXTERIOR LIGHTING WILL BE POLE-MOUNTED LUMINARIES AT DRIVES AND PARKING AREAS. BOTH POLE AND BUILDING MOUNTED FIXTURES WILL FEATURE DOWN- DIRECTIONAL AND SHARP CUTOFF LUMINARIES. ALL WALL MOUNTED LIGHT FIXTURES SHALL BE FULLY SHIELDED TO CONCEAL LIGHT SOURCE. 5. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT IS TO BE FULLY SCREENED FROM PUBLIC VIEW WITH ROOFTOP PARAPET WALLS AND LANDSCAPING. CONDUITS, METERS, VENTS AND OTHER EQUIPMENT ATTACHED TO THE BUILDING OR PROTRUDING FROM THE ROOF SHALL BE PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 6. ALL SIGNAGE TO COMPLY WITH LOCAL SIGN CODE. 7. THE TRASH ENCLOSURES WILL BE MOUNTED ON CONCRETE AND BE CONSTRUCTED OF MATERIALS TO MATCH THE BUILDINGS. ANY GATES CONSTRUCTED WILL BE OF SOLID MATERIAL. 8. BIKE RACKS ARE TO BE PERMANENTLY ANCHORED TO CONCRETE AND WILL NOT INTERFERE WITH PEDESTRIAN WALKWAYS. 9. ALL HANDICAP PARKING SPACES AND RAMPS ARE TO BE VERIFIED WITH CIVIL ENGINEER FOR GRADING, DRAINAGE, AND ACCESSIBLE ROUTE CONSIDERATIONS. HANDICAP PARKING SPACES SHOULD SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES SHOULD SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND NO MORE THAN 1:48 CROSS SLOPE. 10. ALL INTERNAL PEDESTRIAN WALKWAYS SHALL BE DISTINGUISHED FROM DRIVING SURFACES THROUGH THE USE OF DURABLE LOW-MAINTENANCE SURFACE MATERIALS SUCH AS SCORED CONCRETE TO ENHANCE PEDESTRIAN SAFETY AND COMFORT AS WELL AS THE ATTRACTIVENESS OF THE WALKWAYS. 11. ELECTRICAL TRANSFORMERS AND NATURAL GAS EQUIPMENT SHALL BE FULLY SCREENED FROM PUBLIC VIEW BY A SOLID HEDGE OF PLANT MATERIAL OR AN ENCLOSURE MEETING THE CLEARANCE SPECIFICATIONS OF LIGHT AND POWER. SUCH ENCLOSURE MUST MATCH THE PREDOMINATE MATERIALS OF THE BUILDING BEING SERVED. TRANSFORMERS MUST BE WITHIN TEN FEET OF HARD SURFACE. 12. IN ORDER TO COMPLY WITH OPERATIONAL AND PHYSICAL COMPATIBILITY STANDARDS, THE OUTDOOR STORAGE OF PRODUCTS OR MATERIALS, INCLUDING TIRE DISPLAY RACKS OR USED TIRES SHALL BE SCREENED FROM PUBLIC VIEW. IN ADDITION, VENDING MACHINES SHALL BE PLACED INSIDE BUILDINGS OR BEHIND SCREEN WALLS. GENERAL NOTES 3780 East 15th Street, Suite 201 Loveland, Colorado 80538 970.669.8220 E-mail: info@hauserarchitectspc.com HauserArchitectspc.com SHEET Hauser Architects, P.C. 1313 BLUE SPRUCE DR, FORT COLLINS, CO 80524 5/29/2015 1:18:59 PM C:\Users\CurtisK\Google Drive\Current PROJECTS\Raw Urth Designs\RevitProjects\Raw Urth.rvt AMY SASICK RAW URTH DESIGNS ARCHITECTURAL SITE PLAN A-1 3/32" = 1'-0" 1 Site Plan REVISIONS SHEET INDEX SHEET NUMBER SHEET NAME PDP SET ARCHITECTURAL PDP A-1 ARCHITECTURAL SITE PLAN X A-2 ARCHITECTURAL SITE DETAILS X A-3 ELEVATIONS X