HomeMy WebLinkAboutWARREN FEDERAL CREDIT UNION - PDP - PDP150011 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSPRELIMINARY
NOT FOR CONSTRUCTION
Vicinity Map
Scale: 1" = 500'
PROPOSED STREET LIGHT
PROPOSED STORM SEWER MANHOLE
EXISTING SANITARY SEWER MAIN
PROPOSED TELEPHONE LINE
EXISTING GAS
EXISTING STORM SEWER
EXISTING WATER MAIN
EXISTING MANHOLE
PROPOSED STORM INLET
LEGEND
PROPOSED CONCRETE
PROPOSED MINOR CONTOUR
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
PROPOSED MAJOR CONTOUR
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
EXISTING UTILITY POLE
EXISTING GUY WIRE
PROPOSED GAS
EXISTING ELECTRIC LINE PROPOSED ELECTRIC LINE
EXISTING TELEPHONE LINE
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
EXISTING WATER VALVE
PROPOSED SANITARY SEWER MANHOLE
PROPOSED WATER VALVE
EXISTING CONCRETE
EXISTING FLOWLINE, CURB & GUTTER
PROPOSED FLOWLINE, CURB & GUTTER
PROPOSED FENCE
LIMITS OF DEVELOPMENT (LOD)
EXISTING OVERHEAD UTILITY
EXISTING STORM SEWER INLET
PROPOSED UTILITY POLE
EXISTING STREET LIGHT
PROPOSED SWALE
PROPOSED DIRECTION OF OVERLAND FLOW
PROPOSED EMERGENCY OVERFLOW ROUTE
EXISTING FIBER OPTIC LINE
PROPOSED HANDICAP RAMP
EXISTING OVERHEAD ELECTRIC LINE
EXISTING OVERHEAD TELEPHONE LINE
PROPOSED OVERHEAD ELECTRIC LINE
PROPOSED FIBER OPTIC LINE
PROPOSED OVERHEAD TELEPHONE LINE
EXISTING FENCE
PROPOSED WATER SERVICE W/
PROPOSED SANITARY SEWER SERVICE
CURB STOP AND METER PIT
W/ CLEANOUT
AD ALGEBRAIC DIFFERENCE
AE ACCESS EASEMENT
ARV AIR RELEASE VALVE
BOV BLOW OFF VALVE
BW BOTTOM OF WALL
LOT 1
NOT PART OF PDP
LOT 2
PROPOSED BUILDING PAD
FUTURE
BUILDING PAD
0
SCALE: 1" = 20'
20 10 20 40
NOTES:
1. ALL SANITARY SEWER, WATER, AND STORM SEWER CONSTRUCTION, AS WELL
AS POWER AND OTHER "DRY" UTILITY INSTALLATIONS, SHALL CONFORM TO THE
CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS CURRENT AT THE
DATE OF APPROVAL OF THE PLANS BY THE LOCAL ENGINEER.
2. SANITARY SEWER PIPE SHALL BE PVC (SDR 35) UNLESS OTHERWISE NOTED ON
THE PLAN. SEWER PIPE SHALL BE AS SPECIFIED BY THE CITY OF FORT COLLINS
STANDARD PLANS AND SPECIFICATIONS.
3. ALL SANITARY SEWER CLEANOUTS LOCATED IN THE PARKING LOT OR DRIVE
AREA SHALL BE TRAFFIC RATED CLEANOUTS.
4. LENGTH OF PIPE IS MEASURED FROM CENTER OF STRUCTURE TO CENTER OF
STRUCTURE.
5. WATER SERVICES SHALL BE TYPE K COPPER PIPE AND INSTALLED A MINIMUM
OF 5-FEET BELOW FINISHED FLOOR ELEVATION.
6. FIRE LINE SHALL BE PVC (C-900) AS SPECIFIED BY THE CITY OF FORT COLLINS
STANDARD PLANS AND SPECIFICATIONS.
7. HORIZONTAL AND VERTICAL DEFLECTION AT PIPE JOINTS AND BENDS SHALL
127(;&(('
8. ALL STORM SEWER PIPE SHALL BE CLASS III RCP OR HDPE PIPE WITH WATER
TIGHT JOINTS AS NOTED ON THE PLAN. BEDDING FOR RCP SHALL BE PER THE
CITY OF FORT COLLINS STORM SEWER BEDDING DETAIL AND BEDDING FOR
HDPE SHALL BE PER THE CITY OF FORT COLLINS SANITARY SEWER PLASTIC PIPE
BEDDING DETAIL. STORM SEWER PIPE SHALL BE AS SPECIFIED BY THE CITY OF
FORT COLLINS STANDARD PLANS AND SPECIFICATIONS.
9. ALL STORM SEWER SYSTEMS ON SITE WILL BE PRIVATELY OWNED AND
MAINTAINED.
10. LIMITS OF STREET CUT SHOWN ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS
TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
11. PROPOSED EASEMENTS SHOWN WILL BE DEDICATED WITH THE PLAT.
12. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO
CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS,
DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS
PFOJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS
STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF
COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE
CERTIFICATE OF OCCUPANCY.
13. ROOF DRAINS TO CONNECT TO PROPOSED UNDERGROUND STORM SYSTEM.
PRELIMINARY
NOT FOR CONSTRUCTION
LEGEND
PROPOSED ASPHALT PAVEMENT
PROPOSED PERVIOUS PAVERS
PROPOSED CONCRETE WALK
(BOGERT "FILTERPAVE" W/ 6" DRAIN)
PREPARED FOR
PROJ. NO.
DATE:
SCALE (H):
SCALE (V):
CHECKED BY:
PROPOSED BULIDING PAD
FF ELEV=4936.2
FUTURE BUILDING PAD
FF ELEV=4936.2
LOT 1
NOT PART OF PDP
LOT 2
Revisions
No. Date Description By
PREPARED FOR
PROJ. NO.
DATE:
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
1219-048-00
WARREN FEDERAL CREDIT UNION
EAST DRAKE
GRADING PLAN
07/15/2015
1"=20'
N/A
MO
MO
3
RB+B ARCHITECTS, INC.
315 E MOUNTAIN AVE #100
FORT COLLINS, CO 80524
PHONE: 970.484.0117
0
SCALE: 1" = 20'
20 10 20 40
GENERAL NOTES:
1. ALL GRADING SHALL BE CONFINED TO THE PROPERTY BEING DEVELOPED OR
ADJACENT PUBLIC RIGHT-OF-WAY. NO GRADING SHALL BE DONE OUTSIDE OF
PROPERTY LINES UNLESS OTHERWISE SHOWN.
2. LOT 1 IS NOT PART OF THIS PDP SUBMITTAL BUT SHALL BE OVERLOT GRADED TO
DRAIN AS SHOWN.
PRELIMINARY
NOT FOR CONSTRUCTION
PERMEABLE INTERLOCKING
CONCRETE PAVER SECTION
N.T.S.
LOT 1
NOT PART OF PDP
LOT 2
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
LEGEND
PROPOSED DIRECTION OF
OVERLAND FLOW
DRAINAGE BASIN DIVIDE LINE
PROP MAJOR STORM RUNOFF COEFFICIENT
PROP DRAINAGE BASIN AREA
DRAINAGE BASIN NUMBER
DESIGN POINT
NOTES
1. EROSION CONTROL MEASURES TO BE ADDED DURING FCP.
PRELIMINARY
NOT FOR CONSTRUCTION
0
SCALE: 1" = 20'
20 10 20 40
Revisions
No. Date Description By
PREPARED FOR
PROJ. NO.
DATE:
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
1219-048-00
WARREN FEDERAL CREDIT UNION
EAST DRAKE
DRAINAGE PLAN
07/15/2015
1"=20'
N/A
MO
MO
4
RB+B ARCHITECTS, INC.
315 E MOUNTAIN AVE #100
FORT COLLINS, CO 80524
PHONE: 970.484.0117
DESIGNED BY:
1219-048-00
WARREN FEDERAL CREDIT UNION
EAST DRAKE
UTILITY PLAN
07/15/2015
1"=20'
N/A
MO
MO
2
RB+B ARCHITECTS, INC.
315 E MOUNTAIN AVE #100
FORT COLLINS, CO 80524
PHONE: 970.484.0117
CL CENTERLINE
CMP CORRUGATED METAL PIPE
CO CLEAN OUT
DE DRAINAGE EASEMENT
E ELECTRIC
EAE EMERGENCY ACCESS EASEMENT
EG EXISTING GROUND
EL ELEVATION
EOA EDGE OF ASPHALT
EX EXISTING
ESMT EASEMENT
F FIRE LINE
FES FLARED END SECTION
FF FINISHED FLOOR
FG FINISHED GRADE
FH FIRE HYDRANT
FL FLOWLINE
FO FIBER OPTIC
G GAS
GB GRADE BREAK
GD GROUND
GV GATE VALVE
HDPE HIGH DENSITY POLYETHYLENE
HP HIGH POINT
IE IRRIGATION EASEMENT
INV INVERT
IRR IRRIGATION
LF LINEAR FEET
LP LOW POINT
LT LEFT
MH MANHOLE
OHE OVERHEAD ELECTRIC
OHT OVERHEAD TELEPHONE
OHU OVERHEAD UTILITY
PE PEDESTRIAN EASEMENT
PC POINT OF CURVATURE
PCR POINT OF CURB RETURN
PI POINT OF INTERSECTION
PT POINT OF TANGENCY
PVC POLYVINYL CHLORIDE
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
ROW RIGHT-OF-WAY
RT RIGHT
S SANITARY SEWER
STA STATION
SD STORM DRAIN PIPE
SDMH STORM DRAIN MANHOLE
SMH SANITARY SEWER MANHOLE
T TELEPHONE
TB THRUST BLOCK
TBC TOP BACK OF CURB
TCE TEMPORARY CONSTRUCTION EASEMENT
TC TOP OF CONCRETE
TF TOP OF FOUNDATION
TW TOP OF WALL
TYP TYPICAL
UE UTILITY EASEMENT
VB VALVE BOX
VCP VITRIFIED CLAY PIPE
VPC VERTICAL POINT OF CURVATURE
VPI VERTICAL POINT OF INTERSECTION
VPT VERTICAL POINT OF TANGENCY
W WATERLINE
ABBREVIATION LIST
PROPOSED OVERHEAD UTILITY
PROPOSED LIGHT POLES
EXISTING CABLE TV PROPOSED CABLE TV
EXISTING WOOD POST
EXISTING METAL POST
PHASE LINE
Sheet No. Description of Sheets
INDEX OF SHEETS
1
2
3
4
INDEMNIFICATION STATEMENT:
THESE PLANS HAVE BEEN REVIEWED BY THE LOCAL ENTITY FOR
CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BY THE
REVIEWING DEPARTMENT, THE LOCAL ENTITY ENGINEER, OR THE
LOCAL ENTITY FOR ACCURACY AND CORRECTNESS OF THE
CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT
QUANTITIES OF ITEMS ON THE PLANS ARE THE FINAL QUANTITIES
REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS
ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE LOCAL ENTITY
FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE
REQUIRED DURING THE CONSTRUCTION PHASE.
City of Fort Collins
TELEPHONE SERVICE
Century Link (Qwest)
3351 Eastbrook Drive
Fort Collins, Colorado 80525
Contact: Bob Rulli
Xcel Energy
1901 E. Horsetooth Road
Contact: Stephanie Rich
Fort Collins, Colorado 80525
Rob Irish
Ph. 970.225.7828
Ph. 970.377.6403
AD ALGEBRAIC DIFFERENCE
AE ACCESS EASEMENT
ARV AIR RELEASE VALVE
BOV BLOW OFF VALVE
BW BOTTOM OF WALL
CL CENTERLINE
CMP CORRUGATED METAL PIPE
CO CLEAN OUT
DE DRAINAGE EASEMENT
E ELECTRIC
EAE EMERGENCY ACCESS EASEMENT
EG EXISTING GROUND
EL ELEVATION
EOA EDGE OF ASPHALT
EX EXISTING
ESMT EASEMENT
F FIRE LINE
FES FLARED END SECTION
FF FINISHED FLOOR
FG FINISHED GRADE
FH FIRE HYDRANT
FL FLOWLINE
FO FIBER OPTIC
G GAS
GB GRADE BREAK
GD GROUND
GV GATE VALVE
HDPE HIGH DENSITY POLYETHYLENE
HP HIGH POINT
IE IRRIGATION EASEMENT
INV INVERT
IRR IRRIGATION
LF LINEAR FEET
LP LOW POINT
LT LEFT
MH MANHOLE
OHE OVERHEAD ELECTRIC
OHT OVERHEAD TELEPHONE
OHU OVERHEAD UTILITY
PE PEDESTRIAN EASEMENT
PC POINT OF CURVATURE
PCR POINT OF CURB RETURN
PI POINT OF INTERSECTION
PT POINT OF TANGENCY
PVC POLYVINYL CHLORIDE
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
ROW RIGHT-OF-WAY
RT RIGHT
S SANITARY SEWER
STA STATION
SD STORM DRAIN PIPE
SDMH STORM DRAIN MANHOLE
SMH SANITARY SEWER MANHOLE
T TELEPHONE
TB THRUST BLOCK
TBC TOP BACK OF CURB
TCE TEMPORARY CONSTRUCTION EASEMENT
TC TOP OF CONCRETE
TF TOP OF FOUNDATION
TW TOP OF WALL
TYP TYPICAL
UE UTILITY EASEMENT
VB VALVE BOX
VCP VITRIFIED CLAY PIPE
VPC VERTICAL POINT OF CURVATURE
VPI VERTICAL POINT OF INTERSECTION
VPT VERTICAL POINT OF TANGENCY
W WATERLINE
ABBREVIATION LIST
ARCHITECT
RB+B Architects, Inc
315 Mountain Ave #100
Fort Collins, CO 80524
Ph. 970.484.0117
Contact: DAVID KRESS
LANDSCAPE ARCHITECT
BHA Design
1603 Oakridge Dr #100
Fort COllins, CO 80525
Ph. 970.223.7577
Contact: Jerod Huwa
ENGINEER
Interwest Consulting Group
1218 W. Ash, Suite C
Windsor, Colorado 80550
Ph. 970.674.3300
Contact: Skylar Brower
SURVEYOR
King Surveyors, Inc.
650 East Garden Drive
Windsor, Colorado 80550
Ph. 970.686.5011
Contact: Larry Pepek
Sheet No. Description of Sheets
INDEX OF SHEETS
COVER SHEET
UTILITY PLAN
GRADING PLAN
DRAINAGE PLAN
...........................................
...........................................
...........................................
...........................................
INDEMNIFICATION STATEMENT:
THESE PLANS HAVE BEEN REVIEWED BY THE LOCAL ENTITY FOR
CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BY THE
REVIEWING DEPARTMENT, THE LOCAL ENTITY ENGINEER, OR THE
LOCAL ENTITY FOR ACCURACY AND CORRECTNESS OF THE
CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT
QUANTITIES OF ITEMS ON THE PLANS ARE THE FINAL QUANTITIES
REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS
ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE LOCAL ENTITY
FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE
REQUIRED DURING THE CONSTRUCTION PHASE.
UTILITY CONTACTS:
City of Fort Collins
Fort Collins, Colorado 80522
WATER/WASTEWATER
Shane Boyle
Ph. 970.221.6339
700 Wood Street
TELEPHONE SERVICE
Century Link (Qwest)
3351 Eastbrook Drive
Fort Collins, Colorado 80525
Contact: Bob Rulli
NATURAL GAS
Xcel Energy
1901 E. Horsetooth Road
Contact: Stephanie Rich
Fort Collins, Colorado 80525
STORMWATER
Wes Lamarque
Ph. 970.416.2418
LIGHT & POWER
Rob Irish
Ph. 970.221.6700
Ph. 970.225.7828
Ph. 970.377.6403
PRELIMINARY UTILITY PLANS
WARREN FEDERAL CREDIT UNION - EAST DRAKE
LOCATED IN THE NORTHWEST QUARTER OF SECTION 29, T-7-N, R-68-W OF THE 6TH PM
CITY OF FORT COLLINS, COUNTY OF LARIMER, COLORADO
JULY 2015
BENCHMARKS:
PROJECT DATUM: NAVD88
BENCHMARK #17-92
300 FEET SOUTH OF THE SOUTHWEST CORNER OF EAST DRAKE RD. AND TIMBERLINE RD, IN
THE TOP OF AN IRRIGATION STRUCTURE.
ELEVATION=4938.7
BENCHMARK #5-07
SOUTHWEST CORNER OF RIGDEN PARKWAY AND DRAKE RD. ON SOUTHWEST CORNER OF
A CATCH BASIN.
ELEVATION=4926.96
HORIZONTAL DATUM:
COLORADO STATE PLANE COORDINATES NAD83(2007) DATUM.
HORIZONTAL CONTROL BASED UPON TRIMBLE VRS NETWORK.
PREPARED FOR
PROJ. NO.
DATE:
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
1219-048-00
WARREN FEDERAL CREDIT UNION
EAST DRAKE
COVER SHEET
07/15/2015
NA
N/A
MO
MO
1
RB+B ARCHITECTS, INC.
315 E MOUNTAIN AVE #100
FORT COLLINS, CO 80524
PHONE: 970.484.0117