Loading...
HomeMy WebLinkAboutAFFINITY AT FORT COLLINS - PDP - PDP150010 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORTPDP DRAINAGE REPORT FOR AFFINITY FORT COLLINS Prepared For: AFFINITY FORT COLLINS, LLC 1620 N Mamer Road, Bldg. B Spokane Valley, WA 99216 July 1, 2015 Project No. 39704.00 Prepared By: JR Engineering, LLC 2900 South College Avenue, Suite 3D Fort Collins, CO 80525 Page i TABLE OF CONTENTS Table of Contents ............................................................................................................................................... i Vicinity Map ......................................................................................................................................................... 1 General Description and Location .................................................................................................................. 2 Location And Existing Site Characteristics ................................................................................................. 2 Site Soils ........................................................................................................................................................... 2 Floodplain ........................................................................................................................................................ 2 Drainage Basins and Sub-Basins ....................................................................................................................... 3 Major Basin ...................................................................................................................................................... 3 Historic Sub-Basins ........................................................................................................................................ 3 Developed Sub-Basins.................................................................................................................................... 5 Drainage Design Criteria .................................................................................................................................. 7 Regulations ...................................................................................................................................................... 7 Low-Impact Developement .......................................................................................................................... 7 Hydrologic Criteria ........................................................................................................................................ 7 Hydraulic Criteria........................................................................................................................................... 7 Drainage Facility Design .................................................................................................................................... 9 General Concept ............................................................................................................................................ 9 Proposed Retention Facilities .....................................................................................................................10 Future Water Quality/ Detention Facilities .............................................................................................10 Stormwater Pollution Prevention ..................................................................................................................12 Temporary Erosion Control ......................................................................................................................12 Permanent Erosion Control .......................................................................................................................12 Summary & Conclusions .................................................................................................................................13 Existing & Proposed Conditions ................................................................................................................13 References .........................................................................................................................................................15 APPENDIX Appendix A – Site & Soil Descriptions and Characteristics Appendix B – Historic Basin Calculations Appendix C - Proposed Rational & Detention Pond Calculations Appendix D - Existing & Proposed Drainage Plans Appendix E – LID Exhibits Page ii Engineer’s Certification Block I hereby certify that this Project Development Plan Drainage Report for Affinity Fort Collins was prepared by me (or under my direct supervision) for JR Engineering, LLC and the owners thereof and meets or exceeds the criteria of the City of Fort Collins Stormwater Design Standards. ________________________________________ Timothy J. Halopoff, PE Registered Professional Engineer State of Colorado No. 37953 Page 1 VICINITY MAP Page 2 GENERAL DESCRIPTION AND LOCATION LOCATION AND EXISTING SITE CHARACTERISTICS Affinity Fort Collins is located in the southeast quarter of Section 32, Township 7 North, Range 68 West of the 6th Principal Meridian in the City of Fort Collins, Larimer County, Colorado. More specifically, the Affinity Fort Collins site is a 7.22 acre property that is currently undeveloped and is being used for irrigated agricultural purposes. The site is zoned HC (Harmony Corridor District) and will support apartments and associated amenities once developed. The proposed use of the site is a three-story multi-family apartment complex and associated amenities. The proposed concept includes one main apartment building with separate garden area, pool building, and parking and garages around the perimeter of the site. The proposed main building is 167,538 total square feet, with 153 dwelling units. The existing site generally slopes from the southwest to the northeast with slopes ranging between 0.60% and 2.5%. The property is generally covered with sparse native grasses. The site currently drains to the northeast and east. Runoff sheet flows off the east side of the property and a portion of the runoff flows to a point in the north. SITE SOILS The Affinity Fort Collins site soils consist of loamy soil, predominately Nunn clay loam. Nunn clay loam belongs to hydrologic soils Group C. Group C soils have a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Nunn clay loam with 0-3 percent slopes generally has a combined surface layer thickness of approx. 30 inches. Runoff is moderately high, and the hazards of wind erosion are moderately low. Supporting figures can be found in the Appendix, page A-1. FLOODPLAIN The site is shown on FEMA FIRM panel 08069C0994F, dated December 19, 2006. The site lies within Zone X, areas which are determined to be outside the 0.2% annual chance floodplain. The “City of Fort Collins Floodplain Review Checklist for 50% Submittals” checklist is not applicable for this PDP Drainage Report. Page 3 DRAINAGE BASINS AND SUB-BASINS MAJOR BASIN The proposed Affinity Fort Collins site is located in the Fox Meadows major basin. The Fox Meadows Basin encompasses approximately 2.4 square miles in southeast Fort Collins. The basin is bounded by Horsetooth Road on the north, Lemay Avenue on the west, Harmony Road on the south, and the Cache La Poudre River on the east. The Fox Meadows basin is primarily developed with residential development, some commercial areas and the Collindale Golf Course. The basin does not include a major drainageway for conveying flows through the basin, so no regulatory floodplain has been mapped. Storm runoff flows through a network of storm sewers, local drainage channels and detention ponds. The Fox Meadows Basin was studied by two earlier reports: the “Fox Meadows Basin Drainage Master Plan Update”, prepared by ICON Engineering, Inc., dated December 2002 and revised February 2003; and the “Stormwater Quality and Stream Restoration Update to the Fox Meadows Basin Stormwater Master Drainage Plan”, prepared by ICON Engineering, Inc., dated October 2012. The site is located in the second reach, which is generally located between Ziegler Road and Timberline Road. Proposed improvements identified in the Master Plan documents consist of remedial improvements to existing ponds which overtop in the major storm event, and a new detention facility, Ziegler Pond, located east of the mobile home park. The Ziegler Pond was broken into six total detention ponds placed in series in the “Final Drainage and Erosion Control Study for Front Range Village, Fort Collins, Colorado”, prepared by Stantec Consulting, dated February 2007. There are no major drainageways located within or immediately adjacent to the site. The site is shown on FEMA FIRM panel 08069C0994F, dated December 19, 2006. The site lies within Zone X, areas which are determined to be outside the 0.2% annual chance floodplain. An annotated FIRM exhibit is included in Appendix A. HISTORIC SUB-BASINS Affinity Fort Collins is an infill development piece of property. It is governed by the City’s Reasonable Use policy, in which the proposed drainage basins will need to follow the generally accepted principle of releasing the 100-year developed condition flow rate at the same location and magnitude as the 2-year pre-development condition flow rate. There are offsite areas that flow across the proposed development site. Referring to the “Existing Drainage Plan”, included in the Appendix, the following describes the existing condition drainage basins. Page 4 Existing Offsite Drainage Basins (OS): Sub-basin OS1 consists of 7.82 acres of the Harmony Mobile Home community that drains in a northeasterly direction onto the subject property. In the existing condition, runoff from this portion of the mobile home park (assumed 45% impervious based on approximately 8 units per acre and Figure RO-3) is conveyed through the Affinity Fort Collins site. An existing 15” corrugated metal pipe with 2’x1’ square openings is located along the west edge of the mobile home site. In the 100-year event, 15.25 cfs is captured in the pipe and conveyed north, according to data provided by the City of Fort Collins. The flows are taken north and west of the Affinity site to an existing pond. This reduction in flows is assumed to only occur for the 100-year event. Existing Onsite Sub-Basins: The site has two existing onsite drainage basins approximately delineated by a diagonal line stretching from the southwest corner of the site to the northeast corner of the site with sub-basin EX1 on the north half and EX2 on the southern half. Sub-basin EX1 consists of a 4.93 acre area of undeveloped open space with native grasses and weeds covering the majority of the ground and is assumed to be 2% impervious. Runoff from the Harmony Mobile Home community (Sub-basin OS-1) enters the site along the western boundary and joins on-site flows. Runoff generally flows northeasterly across basin EX-1, at slopes ranging from 0.70% to 2.0%, generally leaving the site at the northeast corner near Kingsley Court. Sub-basin EX2 consists of a 3.47 acre area of undeveloped open space with the same ground cover and percentage imperviousness as sub-basin EX-1. Runoff from Pond 286, just south of the site boundary, enters sub-basin EX-2 during the 100 year storm, heads north before turning east and exits the site along the eastern boundary into the Sollenberger property. Existing slopes range from 0.60% to 2.50%. Page 5 DEVELOPED SUB-BASINS The proposed developed condition sub-basins have been designed to mimic the historic basins’ runoff patterns, for both on- and off-site basins. The following describes the proposed conditions on-site drainage basins. Refer to the “Proposed Drainage Plan” in the appendix for reference. Proposed Onsite Sub-Basins: Sub-basin A1 consists of 0.54 acres on the southwest corner of the subject property. Runoff from the proposed building and parking lot travels north to a sump area inlet. Piped flows are conveyed in the storm sewer around the north side of the property and are discharged into the proposed retention pond at the east side of the property. Sub-basin A2 consists of 0.64 acres on the west side of the subject property. Runoff from the proposed building and parking lot is conveyed to a sump area inlet. Runoff from the proposed garages discharges to a grass-lined bio-swale behind the garages, which discharges to the parking lot and is captured in the inlet. Piped flows are conveyed in the storm sewer around the north side of the property and are discharged into the proposed retention pond at the east side of the property. Sub-basin A3 consists of 0.41 acres near the northwest corner of the subject property. Runoff from the proposed building and parking lot is conveyed to a sump area inlet. Piped flows are conveyed in the storm sewer around the north side of the property and are discharged into the proposed retention pond at the east side of the property. Sub-basin A4 consists of 0.31 acres on the north side of the subject property and includes part of the proposed building, courtyard, and garden areas. Runoff is captured in a proposed area inlet, surrounded by a grass buffer in the center of the sub-basin. Piped flows are conveyed in the storm sewer around the north side of the property and are discharged into the proposed retention pond at the east side of the property. Sub-basin A5 consists of 0.91 acres in the center north portion of the subject property and includes the proposed building, garden area, and recreational area. Runoff is conveyed to a proposed sump area inlet in the parking lot. Piped flows are conveyed in the storm sewer on the north side of the property and are discharged into the proposed retention pond at the east side of the property. Sub-basin A6 consists of 0.17 acres on the east side of the subject property and consists of parking lot area. Flows are captured in a sump inlet and are conveyed to the proposed retention pond at the east side of the property. Sub-basin A7 consists of 0.74 acres in the center-east portion of the site and includes a portion of the proposed building and the upper pond of the two onsite retention ponds. Page 6 Runoff enters the upper pond and is conveyed to the proposed retention pond at the east side of the property. Sub-basin A8 consists of 0.89 acres on the north side of the subject property. Runoff from the proposed garages discharges to a grass-lined bio-swale behind the garages, which discharges to the parking lot and is captured in the inlet. Piped flows are conveyed in the storm sewer around the north side of the property and are discharged into the proposed retention pond at the east side of the property. Sub-basin B1 is comprised of 0.16 acres at the southwest side of the proposed building. Flows are captured in an area inlet and are conveyed in the proposed storm sewer around the south side of the building to the proposed retention pond at the east side of the property. Sub-basin B2 is comprised of 0.60 acres at the south side of the site. Flows are captured in an area inlet and are conveyed in the proposed storm sewer around the south side of the building to the proposed retention pond at the east side of the property. Sub-basin B3 is comprised of 0.27 acres of parking lot at the south side of the proposed building. Flows are captured in an area inlet in the parking lot and are conveyed in the proposed storm sewer around the south side of the building to the proposed retention pond at the east side of the property. Sub-basin B4 is comprised of 0.22 acres of parking lot at the south side of the site. Flows are captured in an area inlet in the parking lot and are conveyed in the proposed storm sewer to the proposed retention pond at the east side of the property. Sub-basin B5 is comprised of 0.81 acres of parking lot at the south side of the proposed building. Flows are captured in an area inlet in the parking lot and are conveyed in the proposed storm sewer around the south side of the building to the proposed retention pond at the east side of the property. Sub-basin C is comprised of 0.87 acres of drive aisle on the east side of the subject property. Flows are captured in an area inlet in the street and are conveyed directly to the proposed retention pond at the east side of the property. Sub-basin D is a portion of the east side of the building and the proposed retention pond at the east side of the property. The 0.67-acre sub-basin drains directly to the proposed retention pond. Page 7 DRAINAGE DESIGN CRITERIA REGULATIONS This report was prepared to meet or exceed the City of Fort Collins stormwater criteria. The City of Fort Collins Storm Drainage Design Criteria and Construction Manual (with all current 2011 Revisions)(FCSDDCCM) and the Urban Drainage Flood Control District’s (UDFCD) Drainage Criteria Manual (USDCM) Volumes 1, 2 and 3 were referenced as guidelines for this design. LOW-IMPACT DEVELOPMENT Volume reduction is an important part of the Four Step Process and is fundamental to effective stormwater management. Per City criteria, a minimum of 50 percent of new impervious surface area must be treated by a Low-Impact Development (LID) best management practice (BMP). The proposed LID BMPs will have the effect of slowing runoff through the site lot and increasing infiltration and rainfall interception by encouraging infiltration and careful selection of vegetative cover. The improvements will decrease the runoff coefficient from the site and are expected to have no adverse impact on the timing, quantity, or quality of stormwater runoff. Site-specific LID BMPs are discussed in the following sections of this report and an illustrative LID/Surface Map is provided in Appendix E. HYDROLOGIC CRITERIA The rational method was performed to calculate the peak runoff rates for each basin. Weighted percent imperviousness and weighted runoff coefficients were calculated for each basin using USDCM Tables RO-3 and RO-5 based on Natural Resources Conservation Service (NRCS) Type C hydrologic soil classification and surface characteristics of each basin. The time of concentration was calculated using USDCM Equation RO-3 and the intensity was calculated using the corresponding storm rainfall depth and USDCM Equation RA-3. To more closely match the City of Fort Collins IDF Curve, Coefficient 3 of the UDFCD’s intensity formula was adjusted to 0.7867. The City of Fort Collins area has 2-year, 1-hour rainfall depth of 0.82 inches and a 100-year, 1- hour rainfall depth of 2.86 inches. These depths do account for the 1997 adjusted rainfall depths. The 2- hour 100-year rainfall total is 3.67 inches, based on the rainfall frequencies adopted by the City of Fort Collins. HYDRAULIC CRITERIA This report demonstrates that the proposed stormwater retention and future detention concept is able to reduce the 100-year developed condition flows to the 2-year historical release rates; thereby satisfying the City’s Reasonable Use requirements. The Rational Formula-based Federal Aviation Administration (FAA) method is used to preliminarily size the detention ponds in accordance with City criteria, as the tributary area is less than 20 acres in size. The resulting storage volume is increased by a factor of twenty five (25) percent to better match the result that would be obtained from SWMM modeling, per City criteria. Page 8 In the interim condition, retention ponds will be used to capture the developed conditions runoff from the site until ultimately, an outfall is constructed to convey flows east to the storm drainage system in Ziegler Road. The City requires that retention facilities are sized to capture, at a minimum, the runoff equal to two times the two hour, 100-year storm over the entire site area, plus one foot of freeboard. No credit is taken for infiltration. The ultimate Affinity Fort Collins storm drainage system will be designed to convey the minor and major storm events through the property with the proposed inlets, storm sewer pipes, and swales for the flows being calculated by this report. Per the requirements provided by the City of Fort Collins Storm Drainage Design Criteria and Construction Manual, all inlets and storm pipes will be designed to convey the 100-year storm flows. During the major storm event, the developed condition 100-year storm, the accumulated water depth in the ponds will be held to a maximum level of one-foot below all building finished floor elevations. Additionally, this report summarizes if any, the expected changes to offsite conditions or flows. This drainage report will eventually show that the flow rate released downstream is less than would historically be experienced, and that the sedimentation is lessened through increased infiltration. All swale and pipe outlets will be protected with turf mat or riprap; whichever is most appropriate. Storm sewer pipe outlets will be protected using the requirements set by the USDCM for the protection of downstream conveyance channels and culverts. LID measures have been integrated into this design, which exceeds the requirements set by the City of Fort Collins. In all, 55% of this project’s impervious areas pass through and are treated in LID’s prior to reaching the retention/detention ponds. Page 9 DRAINAGE FACILITY DESIGN GENERAL CONCEPT The proposed improvements to the Affinity site will result in developed condition runoff being conveyed around the proposed building and to the east via storm sewer and surface flow. Low- impact development best management practices are proposed to improve the quality of runoff and aid in reducing peak flows. Specifically, permeable pavement systems are proposed for portions of the parking lot and drive aisle, rain gardens in areas around the proposed building to treat roof drainage, and grass lined bio-swales are proposed behind the garages on the north and west sides of the site to improve water quality. Runoff from the site is captured in inlets located in the parking lot and in open areas adjacent to the building. Runoff is conveyed in storm sewers in an easterly direction to the proposed ponds at the east end of the site. Secondly, surface overflow paths have been provided, such that the 100-year storm flows remain at least 1 foot below the finished floor elevation, in a fully clogged sub-basin condition. With the introduction of a detention pond concept to the site design, there currently exists no storm drain daylight or release outfall that allows Affinity’s flows to reach the storm drain system in Ziegler; where it is allocated to pass the HP channel. Outfall concepts are currently being investigated in collaboration with adjacent landowners, although a specific concept has not been advanced. As a result, the proposed interim drainage concept for the Affinity Fort Collins site utilizes onsite retention until a drainage outfall is in place. In the current design, offsite flows from the Harmony Mobile Home community cross the western boundary of the development site and enter into basin A2. The flows are collected in the grass lined bio-retention (soft-swale) along the western site boundary and conveyed to the north where they are collected by sump inlets. These offsite flows are then routed east through the proposed onsite storm sewer and into the proposed retention pond. In the interim retention condition, offsite runoff during the minor storm will be discharged into the retention pond. In the ultimate detention configuration, minor flows will be routed through the outlet structure of the pond at existing rates. In the interim and ultimate conditions, the 100-year offsite flows will be passed over two weirs, the retention pond weir and the level spreading weir, and will exit the site on its east boundary in the same quantity, character and quality as the historic condition. The future detention system is anticipated to convey the offsite flows through the site, but not to detain or treat them. Existing conditions offsite flows also enter the site from the south, from Pond 286 during the 100- year storm event. At the 100-year level, Pond 286 located immediately south of the site, discharges at 116 cfs over a concrete control weir located at the northeast end of the pond. These flows currently sheet flow onto the Affinity Fort Collins site and they continue to do so with the proposed design. The existing 100-year flows are then routed north into the parking lot and drive Page 10 aisle, and flow into the proposed private at the east end of the Affinity site. When the enlarged retention pond fills, combined 100-year flows will then overtop the proposed weir on the east side of the proposed pond and will sheet flow over the drive aisle to the east, to be conveyed offsite across a level spreading concrete control weir onto the Sollenberger property. PROPOSED RETENTION FACILITIES Because no outfall exists from the site to the east, onsite retention is proposed until a drainage outfall is gained and constructed, at which time the retention ponds will be converted to detention ponds by retrofitting the ponds to drain to the outfall in accordance with City criteria. The onsite retention is designed to hold twice the 100-year volume generated by a 100-year two-hour storm (3.67”) across the entire site with no credit for infiltration. The main proposed retention pond, Pond A, is located on the east side of the proposed building. This pond receives flows directly from the onsite bio-retention swales and storm sewer. Pond B is a secondary retention facility that works in tandem with Pond A. Pond B receives flows from Basin A7 only, and is not connected to Pond A or with the proposed storm sewer system. Pond B has no proposed restriction on the outlet, and drains into Pond A freely. In the event that the water surface elevation in Pond A causes the north storm sewer system to back up, Pond B will act as additional storage for Pond A, essentially acting as one retention facility. The entire Pond A and Pond B retention system provides 5.04 acre-feet of storage with a minimum of 1’ below the finished floor elevations. The total minimum combined retention volume for Ponds A and B is 5.04 acre-feet. Retention calculations are provided in the appendix. FUTURE WATER QUALITY/ DETENTION FACILITIES In addition to the site’s LID’s, the future water quality and detention system will be provided by retrofitting Pond A and eliminating Pond B when the future outfall to Ziegler Road is constructed. Converting Pond A to a detention pond will require raising the bottom of the pond to a minimum elevation in order to permit the pond to drain to the outfall, and providing the pond with adequate cross-slope and longitudinal slope to allow the pond to drain to a center swale leading to the outlet structure. Because the required retention volume is in excess of the required detention volume, Pond B can be eliminated altogether once the outfall is constructed. The City’s Reasonable Use principle limits the rate of flow from developing properties to their 2- year pre-development condition flow rate during the 100-year storm event. The future detention pond release rates were calculated using the onsite 2-year historic flows and allowing the historic Page 11 offsite 100-year flows to pass through the outlet. See Appendix A3 for maps showing the on-site 2- year historic flows and offsite 100-year historic flows. Two potential future outfall alignments are currently being investigated. One involves routing flows directly through the Sollenberger property to the east, with direct conveyance from the Affinity site to Ziegler Road. The second outfall option involves routing developed conditions detained runoff south, around the Sollenberger property and through a series of existing detention ponds. These outfall concepts are currently being investigated and should not impact the ability of the Affinity site to provide onsite retention in the interim condition. The most recent version of the UD-Detention software (Version 2.35, January 2015) was used to determine the ultimate detention volume requirements. Per City of Fort Collins requirements, the calculated detention volume using the FAA method was increased by a factor of 1.25. The calculated water quality capture volume (WQCV) was added to the total factored FAA detention volume, and one-foot of freeboard was planned for in the ultimate detention configuration as well as in the initial retention phase. The outlet structure was also preliminarily designed in the UD- Detention spreadsheet and is based on releasing the 2-year event at historic rates (onsite and offsite) and the 100-year event (onsite only; calculated release based on 2-year historic flows) through the outlet structure, while the 100-year offsite flows are discharged over the weir in addition to the 116 cfs from Pond 286. The weir also serves as an emergency overflow in the event that the outlet structure becomes blocked. See Table 1, below, for future pond sizing and release rates. Table 1: Detention Pond Values Future Detention Pond Storage Volume Required (acre-ft) WQCV Volume Required (acre-ft) Total Volume Required (acre-ft) Storage Volume Provided (acre-ft) 100-yr Max Inflow Rate (cfs) 100-yr Max Release Rate (cfs) A 2.06 0.252 2.313 2.76 35.45 134.46 Future Water Quality/Detention Facilities: Pond A is a future onsite water quality and detention pond located on the east side of the site and collects flows from all onsite basins and from the offsite basin. The pond detains the 100-year developed onsite flows and releases the offsite flows at existing rates over the weir. The future pond will detain the 100-year onsite developed conditions runoff, and release at a rate of the site’s 2-year historic or 0.2 cfs/ acre, whichever is less. The 2-year developed onsite and offsite flows will be released through the outlet structure. In addition to the constructed LID measures, water quality will be provided and will be released via a perforated orifice plate to accomplish a 40-hour release of the WQCV. Page 12 STORMWATER POLLUTION PREVENTION TEMPORARY EROSION CONTROL A temporary erosion control plan is to be implemented for the site during construction. Temporary erosion control measures include, but are not limited to, slope and swale protection, silt fence placed around downstream areas of disturbance, construction vehicle tracking pad at entrances, a designated concrete truck washout basin, designated vehicle fueling areas, inlet protection, and others. All temporary erosion control measures are to be removed after they are deemed unnecessary. PERMANENT EROSION CONTROL Permanent erosion control measures include, but are not limited to, the constructed detention/water quality ponds, riprap pads placed for culvert outlet protection, seeding and mulch placed to enable and established vegetative growth, etc. Long-term maintenance of these erosion control measures shall be the responsibility of the owner of the property. Ultimately before construction is permitted to begin, a more detailed Storm Water Management Plan (SWMP) will need to be performed per the storm drainage criteria requirements of the City of Fort Collins. Page 13 SUMMARY & CONCLUSIONS The proposed concept for the development of the Affinity Fort Collins site involves surface flows and piping of developed conditions flows to a proposed adequately sized onsite retention pond. LID site enhancements will treat the site runoff at the source before allowing the runoff to be conveyed to the proposed retention pond. Offsite flows from the west will be conveyed through the site and directly released. Offsite flows from Pond 286 to the south (100-year flows only) will enter the site from the south and will be bypassed through the Affinity site. Both off-site 100-year flow rates will pass through the site and over the level spreading concrete weir, across its 150 foot length during a major event; in the same character, quality and rate as historically passed through the site. EXISTING & PROPOSED CONDITIONS The existing conditions drainage has two onsite sub-basins with different outfall points on the east side of the subject property. The major differences between the existing condition and the proposed condition are as follows: 1. In the existing condition, Design Point 1 (Basins OS-1 and EX1) discharges near Kingsley Court. In the proposed condition, this offsite and onsite runoff is collected in the proposed storm sewer and retention pond system. In the future condition, these flows will be conveyed to the ultimate Ziegler Road outfall with the remaining onsite flows. 2. The existing condition, flows from Basin EX2 and the 100-year offsite flows from Pond 286 (116 cfs) are both discharged across the east side of the subject property over the level spreading concrete weir. The onsite basin EX2 has a variable concentrated flow path through the site and the offsite flows from Pond 286 enter the Affinity site after being level- spread over the Pond 286 weir. In the proposed condition, the onsite flows will be retained in the proposed retention pond and the 100-year offsite flows from Pond 286 will be allowed to pass over the proposed retention pond’s weir, thus providing no additional detention for the Pond 286 overflows. In the future condition, all onsite flows will be discharged from the future onsite detention pond at allowable historic rates, while the Pond 286 overflows that enter the site will be allowed to pass over the detention pond’s weir. In both proposed and future conditions, all flows that pass over the onsite pond’s weir will be level-spread over a proposed weir as the flows leave the Affinity site on its eastern boundary. The existing conditions drainage patterns are maintained in the proposed and future conditions. The proposed improvements will have no adverse impacts on the flow rate, character, or quality of runoff leaving the site. Page 14 The hydrologic and retention/detention calculations were performed using the required methods as outlined in the City of Fort Collins Amendments to the Urban Drainage and Flood Control District Criteria Manual. The proposed drainage improvements meet or exceed the City’s requirements. This PDP Drainage Report and the complimenting drainage plans and LID plans propose appropriate grading, permanent landscaping, LID BMPs, and onsite facilities (e.g. storm sewer, inlets, retention/detention facilities) that are shown in their preliminary configuration and will be designed in the Final Drainage Report for Affinity Fort Collins with supporting calculations. This report exhibits that both the retention and future detention storm water systems meet or exceed the requirements set forth in the City of Fort Collins “Storm Drainage Criteria Manual and Construction Standards”, along with all its addendums. Page 15 REFERENCES 1. Urban Storm Drainage Criteria Manual (Volumes 1, 2, and 3), Urban Drainage and Flood Control District, June 2001. 2. Storm Drainage Criteria Manual and Construction Standards, City of Fort Collins Storm Water Utility, City of Fort Collins, Colorado, Updated January, 1997. 3. “Hydrologic Group Rating for Larimer County Area, Colorado”, USDA-Natural Resources Conservation Service, National Cooperative Soil Survey. Web Soil Survey URL: http://websoilsurvey.nrcs.usda.gov. [July 21, 2010] SITE & SOIL DESCRIPTIONS AND CHARACTERISTICS (A)  &XVWRP6RLO5HVRXUFH5HSRUW 0DS²+\GURORJLF6RLO*URXS +$5021<02%,/(+20(2))6,7($5($6                                 ƒ  1 ƒ  : ƒ  1 ƒ  : ƒ  1 ƒ  : ƒ  1 ƒ  : 1 0DSSURMHFWLRQ:HE0HUFDWRU&RUQHUFRRUGLQDWHV:*6(GJHWLFV870=RQH1:*6      )HHW      0HWHUV 0DS6FDOHLISULQWHGRQ$SRUWUDLW [ 0$3/(*(1' 0$3,1)250$7,21 $UHDRI,QWHUHVW $2, $UHDRI,QWHUHVW $2, 6RLOV 6RLO5DWLQJ3RO\JRQV $ $' % %' & &' ' 1RWUDWHGRUQRWDYDLODEOH 6RLO5DWLQJ/LQHV $ $' % %' & &' ' 1RWUDWHGRUQRWDYDLODEOH 6RLO5DWLQJ3RLQWV $ $' % %' & &' ' 1RWUDWHGRUQRWDYDLODEOH :DWHU)HDWXUHV 6WUHDPVDQG&DQDOV 7UDQVSRUWDWLRQ 5DLOV ,QWHUVWDWH+LJKZD\V 865RXWHV 0DMRU5RDGV /RFDO5RDGV %DFNJURXQG $HULDO3KRWRJUDSK\ 7KHVRLOVXUYH\VWKDWFRPSULVH\RXU$2,ZHUHPDSSHGDW :DUQLQJ6RLO0DSPD\QRWEHYDOLGDWWKLVVFDOH (QODUJHPHQWRIPDSVEH\RQGWKHVFDOHRIPDSSLQJFDQFDXVH PLVXQGHUVWDQGLQJRIWKHGHWDLORIPDSSLQJDQGDFFXUDF\RIVRLOOLQH SODFHPHQW7KHPDSVGRQRWVKRZWKHVPDOODUHDVRIFRQWUDVWLQJ VRLOVWKDWFRXOGKDYHEHHQVKRZQDWDPRUHGHWDLOHGVFDOH 3OHDVHUHO\RQWKHEDUVFDOHRQHDFKPDSVKHHWIRUPDS PHDVXUHPHQWV 6RXUFHRI0DS 1DWXUDO5HVRXUFHV&RQVHUYDWLRQ6HUYLFH :HE6RLO6XUYH\85/ KWWSZHEVRLOVXUYH\QUFVXVGDJRY &RRUGLQDWH6\VWHP :HE0HUFDWRU (36* 0DSVIURPWKH:HE6RLO6XUYH\DUHEDVHGRQWKH:HE0HUFDWRU SURMHFWLRQZKLFKSUHVHUYHVGLUHFWLRQDQGVKDSHEXWGLVWRUWV GLVWDQFHDQGDUHD$SURMHFWLRQWKDWSUHVHUYHVDUHDVXFKDVWKH $OEHUVHTXDODUHDFRQLFSURMHFWLRQVKRXOGEHXVHGLIPRUHDFFXUDWH FDOFXODWLRQVRIGLVWDQFHRUDUHDDUHUHTXLUHG 7KLVSURGXFWLVJHQHUDWHGIURPWKH86'$15&6FHUWLILHGGDWDDVRI WKHYHUVLRQGDWH V 7DEOH²+\GURORJLF6RLO*URXS +$5021<02%,/(+20( 2))6,7($5($6 +\GURORJLF6RLO*URXS²6XPPDU\E\0DS8QLW²/DULPHU&RXQW\$UHD&RORUDGR &2 0DSXQLWV\PERO 0DSXQLWQDPH 5DWLQJ $FUHVLQ$2, 3HUFHQWRI$2,  )RUW&ROOLQVORDPWR SHUFHQWVORSHV %    1XQQFOD\ORDPWR SHUFHQWVORSHV &    1XQQFOD\ORDPWR SHUFHQWVORSHV &   7RWDOVIRU$UHDRI,QWHUHVW   5DWLQJ2SWLRQV²+\GURORJLF6RLO*URXS +$5021<02%,/( +20(2))6,7($5($6 $JJUHJDWLRQ0HWKRG'RPLQDQW&RQGLWLRQ &RPSRQHQW3HUFHQW&XWRII1RQH6SHFLILHG 7LHEUHDN5XOH+LJKHU &XVWRP6RLO5HVRXUFH5HSRUW   &XVWRP6RLO5HVRXUFH5HSRUW 0DS²+\GURORJLF6RLO*URXS                                     ƒ  1 ƒ  : ƒ  1 ƒ  : ƒ  1 ƒ  : ƒ  1 ƒ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²+\GURORJLF6RLO*URXS +\GURORJLF6RLO*URXS²6XPPDU\E\0DS8QLW²/DULPHU&RXQW\$UHD&RORUDGR &2 0DSXQLWV\PERO 0DSXQLWQDPH 5DWLQJ $FUHVLQ$2, 3HUFHQWRI$2,  1XQQFOD\ORDPWR SHUFHQWVORSHV &    1XQQFOD\ORDPWR SHUFHQWVORSHV &   7RWDOVIRU$UHDRI,QWHUHVW   5DWLQJ2SWLRQV²+\GURORJLF6RLO*URXS $JJUHJDWLRQ0HWKRG'RPLQDQW&RQGLWLRQ &RPSRQHQW3HUFHQW&XWRII1RQH6SHFLILHG 7LHEUHDN5XOH+LJKHU 8QLILHG6RLO&ODVVLILFDWLRQ 6XUIDFH 7KH8QLILHGVRLOFODVVLILFDWLRQV\VWHPFODVVLILHVPLQHUDODQGRUJDQLFPLQHUDOVRLOVIRU HQJLQHHULQJSXUSRVHVRQWKHEDVLVRISDUWLFOHVL]HFKDUDFWHULVWLFVOLTXLGOLPLWDQG SODVWLFLW\LQGH[,WLGHQWLILHVWKUHHPDMRUVRLOGLYLVLRQV L HISTORIC BASIN CALCULATIONS (B) Subdivision: Affinity Fort Collins Project Name: Affinity Fort Collins Location: Fort Collins Project No.: Calculated By: TAB Checked By: 0 Date: 6/18/15 EX1 4.930 2 4.930 2.00 2.00 EX2 3.470 2 3.470 2.00 2.00 TOTAL 8.400 2.00 Weighted % Imp. % Imp. Area (ac) 39704.00 COMPOSITE % IMPERVIOUS CALCULATIONS Weighted % Imp. Basins Total Basin ID Total Area (ac) % Imp. Area (ac) Weighted % Imp. Roofs % Imp. Area (ac) Weighted % Imp. Paved Roads Lawns X:\3970000.all\3970400\Excel\_Denver Files\3970400 Drainage_Calcs - Historic.xlsm Page 1 of 1 6/30/2015 Subdivision: Affinity Fort Collins Project Name: Affinity Fort Collins Location: Fort Collins Project No.: Calculated By: TAB Checked By: 0 Date: FINAL BASIN D.A. Hydrologic Impervious C100 C2 L S Ti L S Cv VEL. Tt COMP. Tc TOTAL Urbanized Tc Tc ID (AC) Soils Group (%) (FT) (%) (MIN) (FT) (%) (FPS) (MIN) (MIN) LENGTH (FT) (MIN) (MIN) EX1 4.93 C 2.00 0.51 0.06 300 1.6 28.2 233 0.9 7.0 0.7 5.8 34.0 533.0 13.0 13.0 EX2 3.47 C 2.00 0.51 0.06 300 1.0 33.0 251 1.1 7.0 0.7 5.6 38.6 551.0 13.1 13.1 NOTES: Ti = (0.395*(1.1 - C5)*(L)^0.5)/((S)^0.33), S in ft/ft Tt=L/60V (Velocity From Fig. 501) Velocity V=Cv*S^0.5, S in ft/ft Tc Check = 10+L/180 For Urbanized basins a minimum Tc of 5.0 minutes is required. For non-urbanized basins a minimum Tc of 10.0 minutes is required Cv 2.5 5 7 10 15 20 DATA (URBANIZED BASINS) INITIAL/OVERLAND (Ti) TRAVEL TIME (Tt) STANDARD FORM SF-2 TIME OF CONCENTRATION SUB-BASIN Tc CHECK 39704.00 6/18/15 Nearly bare ground Grassed waterway Paved areas and shallow paved swales Type of Land Surface Heavy Meadow Tillage/field Short pasture and lawns X:\3970000.all\3970400\Excel\_Denver Files\3970400 Drainage_Calcs - Historic.xlsm Page 1 of 1 6/30/2015 Project Name: Affinity Fort Collins Subdivision: Affinity Fort Collins Project No.: Location: Fort Collins Calculated By: TAB Design Storm: Checked By: 0 Date: TRAVEL TIME STREET Design Point Basin ID Area (Ac) Runoff Coeff. Tc (min) C*A (Ac) I (in/hr) Q (cfs) Tc (min) C*A (Ac) I (in/hr) Q (cfs) Slope (%) Street Flow (cfs) Design Flow (cfs) Slope (%) Pipe Size (inches) Length (ft) Velocity (fps) Tt (min) REMARKS 1 EX1 4.93 0.06 13.0 0.30 2.24 0.7 2 EX2 3.47 0.06 13.1 0.21 2.24 0.5 DIRECT RUNOFF TOTAL RUNOFF STREET PIPE STANDARD FORM SF-3 STORM DRAINAGE SYSTEM DESIGN (RATIONAL METHOD PROCEDURE) 2-Year 39704.00 6/18/15 X:\3970000.all\3970400\Excel\_Denver Files\3970400 Drainage_Calcs - Historic.xlsm Page 1 of 1 6/30/2015 PROPOSED RATIONAL & DETENTION POND CALCULATIONS (C) Subdivision: Affinity Fort Collins Project Name: Affinity Fort Collins Location: Fort Collins Project No.: Calculated By: TAB Checked By: 0 Date: 6/18/15 A1 0.540 100 0.276 51.10 5 0.087 0.80 90 0.177 29.50 81.40 A2 0.635 100 0.159 25.10 5 0.245 1.90 90 0.231 32.70 59.70 A3 0.411 100 0.173 42.10 5 0.115 1.40 90 0.123 26.90 70.40 A4 0.311 100 0.027 8.70 5 0.215 3.50 90 0.069 20.10 32.30 A5 0.914 100 0.481 52.70 5 0.265 1.40 90 0.168 16.50 70.60 A6 0.168 100 0.104 61.90 5 0.022 0.70 90 0.041 22.20 84.80 A7 0.743 100 0.054 7.30 5 0.492 3.30 90 0.197 23.90 34.50 A8 0.894 100 0.000 0.00 5 0.547 3.10 90 0.347 34.90 38.00 B1 0.159 100 0.019 11.80 5 0.056 1.80 90 0.084 47.60 61.20 B2 0.624 100 0.240 38.40 5 0.170 1.40 90 0.214 30.90 70.70 B3 0.269 100 0.232 86.30 5 0.037 0.70 90 0.000 0.00 87.00 B4 0.218 100 0.189 86.60 5 0.029 0.70 90 0.000 0.00 87.30 B5 0.809 100 0.257 31.80 5 0.210 1.30 90 0.342 38.00 71.10 C 0.868 100 0.639 73.70 5 0.219 1.30 90 0.010 1.00 76.00 D 0.673 100 0.034 5.10 5 0.516 3.80 90 0.122 16.30 25.20 OS1 7.820 --- --- --- 45.00 TOTAL 8.234 60.22 Weighted % Imp. % Imp. Area (ac) 39704.00 COMPOSITE % IMPERVIOUS CALCULATIONS Weighted % Imp. Basins Total Basin ID Total Area (ac) % Imp. Area (ac) Weighted % Imp. Roofs % Imp. Area (ac) Weighted % Imp. Paved Roads Lawns X:\3970000.all\3970400\Excel\_Denver Files\3970400 Drainage_Calcs.xlsm Page 1 of 1 6/30/2015 Subdivision: Affinity Fort Collins Project Name: Affinity Fort Collins Location: Fort Collins Project No.: Calculated By: TAB Checked By: 0 Date: FINAL BASIN D.A. Hydrologic Impervious C100 C2 L S Ti L S Cv VEL. Tt COMP. Tc TOTAL Urbanized Tc Tc ID (AC) Soils Group (%) (FT) (%) (MIN) (FT) (%) (FPS) (MIN) (MIN) LENGTH (FT) (MIN) (MIN) A1 0.54 C 81.40 0.75 0.61 61 7.6 3.6 119 2.2 20.0 3.0 0.7 4.2 180.0 11.0 5.0 A2 0.63 C 59.70 0.63 0.40 39 1.4 7.2 381 0.3 15.0 0.8 7.7 14.9 420.0 12.3 12.3 A3 0.41 C 70.40 0.68 0.49 35 1.7 5.5 144 1.1 20.0 2.1 1.2 6.7 179.0 11.0 6.7 A4 0.31 C 32.30 0.57 0.24 20 8.3 3.5 108 0.5 20.0 1.4 1.3 4.7 128.0 10.7 5.0 A5 0.91 C 70.60 0.68 0.50 20 8.3 2.4 228 0.5 20.0 1.4 2.7 5.1 248.0 11.4 5.1 A6 0.17 C 84.80 0.78 0.65 20 2.0 2.9 80 1.0 20.0 2.0 0.7 3.6 100.0 10.6 5.0 A7 0.74 C 34.50 0.57 0.25 20 8.3 3.4 230 1.0 20.0 2.0 1.9 5.4 250.0 11.4 5.4 A8 0.89 C 38.00 0.58 0.27 30 1.3 7.7 732 0.2 15.0 0.7 17.0 24.7 762.0 14.2 14.2 B1 0.16 C 61.20 0.64 0.42 20 8.3 2.8 30 0.5 20.0 1.4 0.4 3.1 50.0 10.3 5.0 B2 0.62 C 70.70 0.68 0.50 20 8.3 2.4 188 2.0 20.0 2.8 1.1 3.5 208.0 11.2 5.0 B3 0.27 C 87.00 0.80 0.68 20 2.0 2.7 157 2.0 20.0 2.8 0.9 3.7 177.0 11.0 5.0 B4 0.22 C 87.30 0.81 0.69 20 2.0 2.7 155 2.0 20.0 2.8 0.9 3.6 175.0 11.0 5.0 B5 0.81 C 71.10 0.68 0.50 20 8.3 2.4 206 2.0 20.0 2.8 1.2 3.6 226.0 11.3 5.0 C 0.87 C 76.00 0.71 0.55 20 2.0 3.6 306 3.0 20.0 3.5 1.5 5.0 326.0 11.8 5.0 D 0.67 C 25.20 0.56 0.20 20 2.0 5.8 262 0.5 20.0 1.4 3.1 8.9 282.0 11.6 8.9 OS1 7.82 C 45.00 0.59 0.31 112 1.5 13.4 990 1.1 20.0 2.1 7.7 21.1 1102.0 16.1 16.1 NOTES: Ti = (0.395*(1.1 - C5)*(L)^0.5)/((S)^0.33), S in ft/ft Tt=L/60V (Velocity From Fig. 501) Velocity V=Cv*S^0.5, S in ft/ft Tc Check = 10+L/180 For Urbanized basins a minimum Tc of 5.0 minutes is required. For non-urbanized basins a minimum Tc of 10.0 minutes is required Cv 2.5 5 7 10 15 20 DATA (URBANIZED BASINS) INITIAL/OVERLAND (Ti) TRAVEL TIME (Tt) STANDARD FORM SF-2 TIME OF CONCENTRATION SUB-BASIN Tc CHECK 39704.00 6/18/15 Nearly bare ground Grassed waterway Paved areas and shallow paved swales Type of Land Surface Heavy Meadow Tillage/field Short pasture and lawns X:\3970000.all\3970400\Excel\_Denver Files\3970400 Drainage_Calcs.xlsm Page 1 of 1 6/30/2015 Project Name: Affinity Fort Collins Subdivision: Affinity Fort Collins Project No.: Location: Fort Collins Calculated By: TAB Design Storm: Checked By: 0 Date: TRAVEL TIME STREET Design Point Basin ID Area (Ac) Runoff Coeff. Tc (min) C*A (Ac) I (in/hr) Q (cfs) Tc (min) C*A (Ac) I (in/hr) Q (cfs) Slope (%) Street Flow (cfs) Design Flow (cfs) Slope (%) Pipe Size (inches) Length (ft) Velocity (fps) Tt (min) REMARKS 1 OS1 7.82 0.31 16.1 2.42 2.03 4.9 Offsite flows enter site at DP1 A1 0.54 0.61 5.0 0.33 3.14 1.0 Sump Inlet A1 2A A2 0.63 0.40 12.3 0.25 2.29 0.6 16.1 2.67 2.03 5.4 Surface flows at inlet A2 2 A2 16.1 3.00 2.03 6.1 Flow in the Pipe at inlet A2 3 A3 0.41 0.49 6.7 0.20 2.88 0.6 16.1 3.20 2.03 6.5 Sump Inlet A3 4 A4 0.31 0.24 5.0 0.07 3.14 0.2 16.1 3.27 2.03 6.6 Sump Inlet A4 5 A5 0.91 0.50 5.1 0.46 3.12 1.4 16.1 3.73 2.03 7.6 Sump Inlet A5 6 A6 0.17 0.65 5.0 0.11 3.14 0.3 16.1 3.84 2.03 7.8 Sump Inlet A6 7 A7 0.74 0.25 5.4 0.19 3.08 0.6 16.1 4.03 2.03 8.2 Pond B A8 0.89 0.27 14.2 0.24 2.15 0.5 Sump Inlet A8 B1 0.16 0.42 5.0 0.07 3.14 0.2 Sump Inlet B1 8 B2 0.62 0.50 5.0 0.31 3.14 1.0 5.0 0.38 3.14 1.2 Sump Inlet B2 9 B3 0.27 0.68 5.0 0.18 3.14 0.6 5.0 0.56 3.14 1.8 Sump Inlet B3 10 B4 0.22 0.69 5.0 0.15 3.14 0.5 5.0 0.71 3.14 2.2 Sump Inlet B4 11 B5 0.81 0.50 5.0 0.40 3.14 1.3 5.0 1.11 3.14 3.5 Sump Inlet B5 C 0.87 0.55 5.0 0.48 3.13 1.5 Sump Inlet C D 0.67 0.20 8.9 0.13 2.61 0.3 12 16.1 5.99 2.03 12.2 Pond A DIRECT RUNOFF TOTAL RUNOFF STREET PIPE STANDARD FORM SF-3 STORM DRAINAGE SYSTEM DESIGN (MINOR STORM) (RATIONAL METHOD PROCEDURE) 2-Year 39704.00 6/18/15 X:\3970000.all\3970400\Excel\_Denver Files\3970400 Drainage_Calcs.xlsm Page 1 of 1 6/30/2015 STANDARD FORM SF-3 STORM DRAINAGE SYSTEM DESIGN (MAJOR STORM) (RATIONAL METHOD PROCEDURE) Project Name: Affinity Fort Collins Subdivision: Affinity Fort Collins Project No.: Location: Fort Collins Calculated By: TAB Design Storm: Checked By: 0 Date: TRAVEL TIME STREET Design Point Basin ID Area (Ac) Runoff Coeff. Tc (min) C*A (Ac) I (in/hr) Q (cfs) Tc (min) C*A (Ac) I (in/hr) Q (cfs) Slope (%) Street Flow (cfs) Design Flow (cfs) Slope (%) Pipe Size (inches) Length (ft) Velocity (fps) Tt (min) REMARKS OS1 7.82 0.59 16.1 4.61 7.07 32.6 Offsite flows enter site at DP1 Reduction in flows from Exsting 15" CMP 1 16.1 2.45 7.07 17.3 DP1 Flows to DP2A A1 0.54 0.75 5.0 0.40 10.94 4.4 Sump Inlet A1 2A A2 0.63 0.63 12.3 0.40 8.00 3.2 16.1 2.85 7.07 20.2 Surface flows at inlet A2 2 16.1 3.25 7.07 23.0 Flow in the Pipe at inlet A2 3 A3 0.41 0.68 6.7 0.28 10.05 2.8 16.1 5.69 7.07 40.2 Sump Inlet A3 4 A4 0.31 0.57 5.0 0.18 10.94 2.0 16.1 5.87 7.07 41.5 Sump Inlet A4 5 A5 0.91 0.68 5.1 0.62 10.88 6.7 16.1 6.49 7.07 45.9 Sump Inlet A5 6 A6 0.17 0.78 5.0 0.13 10.94 1.4 16.1 6.62 7.07 46.8 Sump Inlet A6 7 A7 0.74 0.57 5.4 0.42 10.74 4.5 16.1 7.04 7.07 49.8 Pond B A8 0.89 0.58 14.2 0.52 7.50 3.9 Sump Inlet A8 B1 0.16 0.64 5.0 0.10 10.94 1.1 Sump Inlet B1 8 B2 0.62 0.68 5.0 0.42 10.94 4.6 5.0 0.52 10.94 5.7 Sump Inlet B2 9 B3 0.27 0.80 5.0 0.22 10.94 2.4 5.0 0.74 10.94 8.1 Sump Inlet B3 10 B4 0.22 0.81 5.0 0.18 10.94 2.0 5.0 0.92 10.94 10.1 Sump Inlet B4 11 B5 0.81 0.68 5.0 0.55 10.94 6.0 5.0 1.47 10.94 16.1 Sump Inlet B5 C 0.87 0.71 5.0 0.62 10.91 6.8 Sump Inlet C D 0.67 0.56 8.9 0.38 9.11 3.5 12 16.1 10.03 7.07 70.9 Pond A 39704.00 PIPE 100-Year DIRECT RUNOFF TOTAL RUNOFF STREET 6/18/15 X:\3970000.all\3970400\Excel\_Denver Files\3970400 Drainage_Calcs.xlsm Page 1 of 1 6/30/2015 Tributary Area tc Q5 Q100 Sub-basin (acres) C5 C100 (min) (cfs) (cfs) A1 0.54 0.61 0.75 5.00 1.0 4.4 A2 0.63 0.40 0.63 12.33 0.6 3.2 A3 0.41 0.49 0.68 6.70 0.6 2.8 A4 0.31 0.24 0.57 5.00 0.2 1.9 A5 0.91 0.50 0.68 5.11 1.4 6.8 A6 0.17 0.65 0.78 5.00 0.3 1.4 A7 0.74 0.25 0.57 5.36 0.6 4.5 A8 0.89 0.27 0.58 14.23 0.5 3.9 B1 0.16 0.42 0.64 5.00 0.2 1.1 B2 0.62 0.50 0.68 5.00 1.0 4.6 B3 0.27 0.68 0.80 5.00 0.6 2.4 B4 0.22 0.69 0.81 5.00 0.5 1.9 B5 0.81 0.50 0.68 5.00 1.3 6.0 C 0.87 0.55 0.71 5.05 1.5 6.7 D 0.67 0.20 0.56 8.94 0.4 3.4 OS1 7.82 0.31 0.59 16.12 4.9 32.6 BASIN SUMMARY TABLE X:\3970000.all\3970400\Excel\_Denver Files\3970400 Drainage_Calcs.xlsm Page 1 of 1 6/30/2015 Subdivision: Affinity Fort Collins Project Name: Affinity Fort Collins Location: Fort Collins Project No.: 39704.00 Calculated By: TAB Checked By: Date: 6/22/2015 Area (ac): 8.23 100-yr 2-hr (in): 3.67 Runoff Volume (ac-in): 30.22 (no credit taken for infiltration) Minimum Design Volume (ac-ft): 5.04 (2 times the two times the two hour, 100-year storm) RETENTION CALCULATIONS POND A Subdivision Affinity Fort Collins Project Name: Affinity Fort Collins Location Fort Collins Project No. 39704.00 By: TAB Checked By: Date: 6/22/2015 Elevation Surface Area Surface Area Lower Surface + Average Depth Volume Cumulative Volume Cumulative Volume (square feet) (acres) Upper Surface Surface Area (feet) (cubic feet) (cubic feet) (acre feet) 4930.00 14,890 0.34 14,890 7,445 0.00 0 0 0.00 4931.00 14,892 0.34 29,782 14,891 1.00 14,891 14,891 0.34 4932.00 14,893 0.34 29,785 14,893 1.00 14,893 29,784 0.68 4933.00 14,895 0.34 29,788 14,894 1.00 14,894 44,678 1.03 4934.00 14,896 0.34 29,791 14,896 1.00 14,896 59,573 1.37 4935.00 15,532 0.36 30,428 15,214 1.00 15,214 74,787 1.72 4936.00 18,166 0.42 33,698 16,849 1.00 16,849 91,636 2.10 4937.00 18,167 0.42 36,333 18,167 1.00 18,167 109,803 2.52 4938.00 18,169 0.42 36,336 18,168 1.00 18,168 127,971 2.94 4939.00 18,170 0.42 36,339 18,170 1.00 18,170 146,140 3.35 4940.00 18,171 0.42 36,341 18,171 1.00 18,171 164,311 3.77 4941.00 18,172 0.42 36,343 18,172 1.00 18,172 182,482 4.19 Pond Volume POND A - RETENTION POND A - RETENTION PREPARED BY JR ENGINEERING, 6/30/2015 POND B Subdivision Affinity Fort Collins Project Name: Affinity Fort Collins Location Fort Collins Project No. 39704.00 By: TAB Checked By: Date: 6/22/2015 Elevation Surface Area Surface Area Lower Surface + Average Depth Volume Cumulative Volume Cumulative Volume (square feet) (acres) Upper Surface Surface Area (feet) (cubic feet) (cubic feet) (acre feet) 4933.22 0 0.00 0 0 0.00 0 0 0.00 4934.00 1,932 0.04 1,932 966 0.78 753 753 0.02 4935.00 7,087 0.16 9,019 4,510 1.00 4,510 5,263 0.12 4936.00 9,119 0.21 16,206 8,103 1.00 8,103 13,366 0.31 4937.00 9,947 0.23 19,066 9,533 1.00 9,533 22,899 0.53 4938.00 10,711 0.25 20,658 10,329 1.00 10,329 33,228 0.76 4939.00 13,286 0.31 23,997 11,999 1.00 11,999 45,226 1.04 4940.00 14,139 0.32 27,425 13,713 1.00 13,713 58,939 1.35 4941.00 14,907 0.34 29,046 14,523 1.00 14,523 73,462 1.69 4942.00 15,363 0.35 30,270 15,135 1.00 15,135 88,597 2.03 Pond Volume POND B - RETENTION POND B - RETENTION PREPARED BY JR ENGINEERING, 6/30/2015 Project: Basin ID: Design Information (Input): Design Information (Input): Catchment Drainage Imperviousness Ia = 60.36 percent Catchment Drainage Imperviousness I a = 60.36 percent Catchment Drainage Area A = 8.210 acres Catchment Drainage Area A = 8.210 acres Predevelopment NRCS Soil Group Type = C A, B, C, or D Predevelopment NRCS Soil Group Type = C A, B, C, or D Return Period for Detention Control T = 2 years (2, 5, 10, 25, 50, or 100) Return Period for Detention Control T = 100 years (2, 5, 10, 25, 50, or 100) Time of Concentration of Watershed Tc = 13 minutes Time of Concentration of Watershed Tc = 13 minutes Allowable Unit Release Rate q = 0.14 cfs/acre Allowable Unit Release Rate q = 0.14 cfs/acre One-hour Precipitation P1 = 0.82 inches One-hour Precipitation P 1 = 2.86 inches Design Rainfall IDF Formula i = C1 * P1 /(C2 +Tc )^C3 Design Rainfall IDF Formula i = C1 * P1 /(C2 +Tc )^C3 Coefficient One C1 = 28.50 Coefficient One C 1 = 28.50 Coefficient Two C2 = 10 Coefficient Two C 2 = 10 Coefficient Three C3 = 0.789 Coefficient Three C 3 = 0.789 Determination of Average Outflow from the Basin (Calculated): Determination of Average Outflow from the Basin (Calculated): Runoff Coefficient C = 0.41 Runoff Coefficient C = 0.63 Inflow Peak Runoff Qp-in = 6.61 cfs Inflow Peak Runoff Qp-in = 35.45 cfs Allowable Peak Outflow Rate Qp-out = 1.11 cfs Allowable Peak Outflow Rate Qp-out = 1.11 cfs Mod. FAA Minor Storage Volume = 7,794 cubic feet Mod. FAA Major Storage Volume = 71,828 cubic feet Mod. FAA Minor Storage Volume = 0.179 acre-ft Mod. FAA Major Storage Volume = 1.649 acre-ft 5 <- Enter Rainfall Duration Incremental Increase Value Here (e.g. 5 for 5-Minutes) Rainfall Rainfall Inflow Adjustment Average Outflow Storage Rainfall Rainfall Inflow Adjustment Average Outflow Storage Duration Intensity Volume Factor Outflow Volume Volume Duration Intensity Volume Factor Outflow Volume Volume minutes inches / hr acre-feet "m" cfs acre-feet acre-feet minutes inches / hr acre-feet "m" cfs acre-feet acre-feet (input) (output) (output) (output) (output) (output) (output) (input) (output) (output) (output) (output) (output) (output) 5 2.76 0.064 1.00 1.11 0.008 0.056 5 9.62 0.343 1.00 1.11 0.008 0.335 10 2.20 0.102 1.00 1.11 0.015 0.087 10 7.67 0.546 1.00 1.11 0.015 0.531 15 1.84 0.128 0.94 1.04 0.022 0.107 15 6.43 0.687 0.94 1.04 0.022 0.666 20 1.60 0.148 0.83 0.92 0.025 0.123 20 5.57 0.793 0.83 0.92 0.025 0.768 25 1.41 0.164 0.76 0.85 0.029 0.135 25 4.93 0.878 0.76 0.85 0.029 0.849 30 1.27 0.177 0.72 0.80 0.033 0.144 30 4.44 0.949 0.72 0.80 0.033 0.916 35 1.16 0.188 0.69 0.76 0.037 0.151 35 4.04 1.008 0.69 0.76 0.037 0.972 40 1.07 0.198 0.66 0.74 0.041 0.157 40 3.72 1.061 0.66 0.74 0.041 1.020 45 0.99 0.206 0.65 0.72 0.045 0.162 45 3.45 1.107 0.65 0.72 0.045 1.062 50 0.92 0.214 0.63 0.70 0.048 0.166 50 3.22 1.148 0.63 0.70 0.048 1.100 55 0.87 0.221 0.62 0.69 0.052 0.169 55 3.03 1.186 0.62 0.69 0.052 1.133 60 0.82 0.228 0.61 0.68 0.056 0.172 60 2.85 1.220 0.61 0.68 0.056 1.164 65 0.77 0.234 0.60 0.67 0.060 0.174 65 2.70 1.252 0.60 0.67 0.060 1.192 70 0.74 0.239 0.59 0.66 0.064 0.175 70 2.57 1.281 0.59 0.66 0.064 1.217 75 0.70 0.244 0.59 0.65 0.067 0.177 75 2.45 1.308 0.59 0.65 0.067 1.241 80 0.67 0.249 0.58 0.65 0.071 0.178 80 2.34 1.334 0.58 0.65 0.071 1.263 85 0.64 0.253 0.58 0.64 0.075 0.178 85 2.24 1.358 0.58 0.64 0.075 1.283 90 0.62 0.258 0.57 0.64 0.079 0.179 90 2.15 1.381 0.57 0.64 0.079 1.302 95 0.59 0.262 0.57 0.63 0.083 0.179 95 2.07 1.403 0.57 0.63 0.083 1.320 100 0.57 0.266 0.57 0.63 0.087 0.179 100 2.00 1.423 0.57 0.63 0.087 1.337 105 0.55 0.269 0.56 0.63 0.090 0.179 105 1.93 1.443 0.56 0.63 0.090 1.352 Project: Basin ID: UDFCD DETENTION BASIN VOLUME ESTIMATING WORKBOOK Version 2.35, Released January 2015 DETENTION VOLUME BY THE MODIFIED FAA METHOD Affinity Fort Collins PDP EX1 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 0 50 100 150 200 250 300 350 Volume (acre-feet) Duration (Minutes) Inflow and Outflow Volumes vs. Rainfall Duration Minor Storm Inflow Volume Minor Storm Outflow Volume Minor Storm Storage Volume Major Storm Inflow Volume Major Storm Outflow Volume Major Storm Storage Volume Copy of UD-Detention_v2.35 - DETENTION POND.xls, Modified FAA 6/30/2015, 4:16 PM Project: Basin ID: Design Information (Input): Width of Basin Bottom, W = ft Right Triangle OR… Length of Basin Bottom, L = ft Isosceles Triangle OR… Dam Side-slope (H:V), Zd = ft/ft Rectangle OR… Circle / Ellipse OR… Irregular (Use Overide values in cells G32:G52) New Minor Volume: 0.431 MINOR MAJOR Storage Requirement from Sheet 'Modified FAA': 0.18 1.65 acre-ft. Stage-Storage Relationship: Storage Requirement from Sheet 'Hydrograph': acre-ft. Storage Requirement from Sheet 'Full-Spectrum': acre-ft. New Major Volume: 2.313 Labels Water Side Basin Basin Surface Surface Volume Surface Volume Target Volumes for WQCV, Minor, Surface Slope Width at Length at Area at Area at Below Area at Below for WQCV, Minor, & Major Storage Elevation (H:V) Stage Stage Stage Stage Stage Stage Stage & Major Storage Stages ft ft/ft ft ft ft 2 ft 2 User ft 3 acres acre-ft Volumes (input) (input) Below El. (output) (output) (output) Overide (output) (output) (output) (for goal seek) 4929.50 (input) 0 0.000 0.000 4930.00 0.00 0.00 457 114 0.010 0.003 4931.00 0.00 0.00 8,466 4,576 0.194 0.105 4932.00 0.00 0.00 14,900 16,259 0.342 0.373 4933.00 0.00 0.00 14,900 31,159 0.342 0.715 4934.00 0.00 0.00 18,166 47,692 0.417 1.095 4935.00 0.00 0.00 18,166 65,858 0.417 1.512 4936.00 0.00 0.00 18,166 84,024 0.417 1.929 4937.00 0.00 0.00 18,166 102,190 0.417 2.346 4938.00 0.00 0.00 18,166 120,356 0.417 2.763 100 YR WSEL 4939.00 0.00 0.00 18,166 138,522 0.417 3.180 4940.00 0.00 0.00 18,166 156,688 0.417 3.597 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Project: Basin ID: STAGE-STORAGE SIZING FOR DETENTION BASINS 4929.50 4931.50 4933.50 4935.50 4937.50 4939.50 4941.50 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 Stage (ft. elev.) Storage (acre-feet) STAGE-STORAGE CURVE FOR THE POND Copy of UD-Detention_v2.35 - DETENTION POND.xls, Basin 6/30/2015, 4:16 PM Project: Basin ID: WQCV Design Volume (Input): Catchment Imperviousness, Ia = 60.4 percent Catchment Area, A = 8.21 acres Diameter of holes, D = 0.960 inches Depth at WQCV outlet above lowest perforation, H = 1.3 feet Number of holes per row, N = 1 Vertical distance between rows, h = 4.00 inches OR Number of rows, NL = 3.00 Orifice discharge coefficient, Co = 0.63 Height of slot, H = inches Slope of Basin Trickle Channel, S = 0.005 ft / ft Width of slot, W = inches Time to Drain the Pond = 40 hours Watershed Design Information (Input): 1.3 Percent Soil Type A = 0 % Percent Soil Type B = 0 % Percent Soil Type C/D = 100 % DI Outlet Design Information (Output): Water Quality Capture Volume, WQCV = 0.307 watershed inches Water Quality Capture Volume (WQCV) = 0.210 acre-feet 0.00 Design Volume (WQCV / 12 * Area * 1.2) Vol = 0.252 acre-feet Outlet area per row, Ao = 0.72 square inches Total opening area at each row based on user-input above, Ao = 0.72 square inches Total opening area at each row based on user-input above, Ao = 0.005 square feet 3 Row 1 Row 2 Row 3 Row 4 Row 5 Row 6 Row 7 Row 8 Row 9 Row 10 Row 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row 21 Row 22 Row 23 Row 23 ΣΣΣΣ 4932.04 4932.37 4932.71 Flow 4929.50 0.0000 0.0000 0.0000 0.00 4930.00 0.0000 0.0000 0.0000 0.00 4931.00 0.0000 0.0000 0.0000 0.00 4932.00 0.0000 0.0000 0.0000 0.00 4933.00 0.0249 0.0202 0.0137 0.06 4934.00 0.0356 0.0324 0.0289 0.10 4935.00 0.0437 0.0412 0.0384 0.12 4936.00 0.0506 0.0484 0.0461 0.15 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Worksheet Protected Project: Basin ID: STAGE-DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET Affinity Fort Collins PDP EX1 4929.00 4930.00 4931.00 4932.00 4933.00 4934.00 4935.00 4936.00 4937.00 0.00 0.02 0.04 0.06 0.08 0.10 0.12 0.14 0.16 Stage (feet, elev.) Discharge (cfs) STAGE-DISCHARGE CURVE FOR THE WQCV OUTLET STRUCTURE Copy of UD-Detention_v2.35 - DETENTION POND.xls, WQCV 6/30/2015, 4:16 PM Project: Basin ID: X 1 #1 Vertical #2 Vertical Sizing the Restrictor Plate for Circular Vertical Orifices or Pipes (Input) Orifice Orifice Water Surface Elevation at Design Depth Elev: WS = 4,938.50 feet Pipe/Vertical Orifice Entrance Invert Elevation Elev: Invert = 4,929.10 feet Required Peak Flow through Orifice at Design Depth Q = 1.11 cfs Pipe/Vertical Orifice Diameter (inches) Dia = 18.0 inches Orifice Coefficient Co = 0.63 Full-flow Capacity (Calculated) Full-flow area Af = 1.77 sq ft Half Central Angle in Radians Theta = 3.14 rad Full-flow capacity Qf = 26.3 cfs Percent of Design Flow = 2361% Calculation of Orifice Flow Condition Half Central Angle (0<Theta<3.1416) Theta = 0.59 rad Flow area Ao = 0.07 sq ft Top width of Orifice (inches) To = 10.03 inches Height from Invert of Orifice to Bottom of Plate (feet) Yo = 0.13 feet Elevation of Bottom of Plate Elev Plate Bottom Edge = 4,929.23 feet Resultant Peak Flow Through Orifice at Design Depth Qo = 1.1 cfs Width of Equivalent Rectangular Vertical Orifice Equivalent Width = 0.54 feet Centroid Elevation of Equivalent Rectangular Vertical Orifice Equiv. Centroid El. = 4,929.17 feet RESTRICTOR PLATE SIZING FOR CIRCULAR VERTICAL ORIFICES Copy of UD-Detention_v2.35 - DETENTION POND.xls, Restrictor Plate 6/30/2015, 4:16 PM Project: Basin ID: Design Information (Input): #1 Horiz. #2 Horiz. #1 Vert. #2 Vert. Circular Opening: Diameter in Inches Dia. = inches OR Rectangular Opening: Width in Feet W = 5.47 1.00 0.54 ft. Length (Height for Vertical) L or H = 5.47 0.50 0.13 ft. Percentage of Open Area After Trash Rack Reduction % open = 65 100 100 % Orifice Coefficient Co = 0.63 0.63 0.63 Weir Coefficient Cw = 3.00 Orifice Elevation (Bottom for Vertical) Eo = 4933.50 4,932.60 4,929.10 ft. Calculation of Collection Capacity: Net Opening Area (after Trash Rack Reduction) Ao = 19.45 0.50 0.07 sq. ft. OPTIONAL: User-Overide Net Opening Area Ao = sq. ft. Perimeter as Weir Length Lw = 18.05 ft. OPTIONAL: User-Overide Weir Length Lw = ft. Top Elevation of Vertical Orifice Opening, Top = 4933.10 4929.23 ft. Center Elevation of Vertical Orifice Opening, Cen = 4932.85 4929.17 ft. Horizontal Orifices Vertical Orifices Labels Water WQCV #1 Horiz. #1 Horiz. #2 Horiz. #2 Horiz. #1 Vert. #2 Vert. Total Target Volumes for WQCV, Minor, Surface Plate/Riser Weir Orifice Weir Orifice Collection Collection Collection for WQCV, Minor, & Major Storage Elevation Flow Flow Flow Flow Flow Capacity Capacity Capacity & Major Storage W.S. Elevations ft cfs cfs cfs cfs cfs cfs cfs cfs Volumes (input) (linked) (User-linked) (output) (output) (output) (output) (output) (output) (output) (link for goal seek) 4929.50 0.00 0.00 0.00 0.00 0.00 0.00 0.20 0.00 4930.00 0.00 0.00 0.00 0.00 0.00 0.00 0.32 0.00 4931.00 0.00 0.00 0.00 0.00 0.00 0.00 0.48 0.00 4932.00 0.00 0.00 0.00 0.00 0.00 0.00 0.60 0.00 4933.00 0.06 0.00 0.00 0.00 0.00 0.90 0.69 0.69 4934.00 0.10 19.15 69.53 0.00 0.00 2.71 0.78 0.78 4935.00 0.12 99.49 120.43 0.00 0.00 3.71 0.85 0.85 4936.00 0.15 214.06 155.47 0.00 0.00 4.49 0.93 0.93 4937.00 #N/A 354.59 183.95 0.00 0.00 5.15 0.99 #N/A 4938.00 #N/A 516.94 208.58 0.00 0.00 5.74 1.05 #N/A 4939.00 #N/A 698.50 230.60 0.00 0.00 6.27 1.11 #N/A 4940.00 #N/A 897.41 250.68 0.00 0.00 6.76 1.16 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Project: Basin ID: Affinity Fort Collins PDP EX1 STAGE-DISCHARGE SIZING OF THE WEIRS AND ORIFICES (INLET CONTROL) 4929.5 4931.5 4933.5 4935.5 4937.5 4939.5 4941.5 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Stage (feet, elev.) Discharge (cfs) STAGE-DISCHARGE CURVE FOR THE OUTLET STRUCTURE Copy of UD-Detention_v2.35 - DETENTION POND.xls, Outlet 6/30/2015, 4:16 PM EXISTING & PROPOSED DRAINAGE PLANS (D) A Westrian Company AFFINITY FORT COLLINS EXISTING CONDITIONS DRAINAGE PLAN HARMONY MOBILE HOME COMMUNITY SOLLENBERGER PROPERTY X:\3970000.all\3970400\Drawings\_Denver Files\3970400DRH01-PDP.dwg, EX Conditions, 6/30/2015 2:01:51 PM, BurnsR A Westrian Company AFFINITY FORT COLLINS PROPOSED CONDITIONS DRAINAGE MAP R R R R R R R R R R R R R R R R R R R R R R R R R X:\3970000.all\3970400\Drawings\_Denver Files\3970400DRF01-PDP.dwg, 24x36 Title Landscape, 6/30/2015 4:42:58 PM, BurnsR LID EXHIBITS (E) A Westrian Company AFFINITY FORT COLLINS PROPOSED LID IMPLEMENTATION PLAN AREA DESCRIPTION AREA (SF) % OF TOTAL NEW IMPERVIOUS AREA AFFLUENT TO L.I.D. BMP'S 97,192 44% PICP AREA 25,390 11% TOTAL TREATED AREA 122,582 55% NEW IMPERVIOUS AREA NOT TREATED 99,394 45% TOTAL IMPERVIOUS AREA 221,976 100% IMPERVIOUS AREA TREATMENT RATIO R R R R R R R R R R R R R R R R R R R R R R R R R X:\3970000.all\3970400\Drawings\_Denver Files\2015-06-26 NEW IMPERVIOUS AREA.dwg, 24x36 Title Landscape, 6/29/2015 5:19:38 PM, BurnsR A Westrian Company AFFINITY FORT COLLINS PERMEABLE PAVEMENT AREA EXHIBIT LID IMPLEMENTATION PLAN SURFACE MATERIAL AREA (SF) % OF TOTAL PERMEABLE INTERLOCKING CONCRETE PAVERS (PICP) 25,390 71% IMPERVIOUS ASPHALT PARKING 10,395 29% TOTAL 35,785 100% PARKING AREAS R R R R R R R R R R R R R R R R R R R R R R R R R X:\3970000.all\3970400\Drawings\_Denver Files\2015-06-26 - PICP Exhibit.dwg, 24x36 Title Landscape, 6/29/2015 3:25:07 PM, BurnsR #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Routing 2: Water flows through WQCV plate and #1 vertical opening and #1 horizontal opening into #2 vertical opening (#2 horizontal opening is not used). STAGE-DISCHARGE SIZING OF THE WEIRS AND ORIFICES (INLET CONTROL) Affinity Fort Collins PDP EX1 Current Routing Order is #2 W.S. EL. WQ W.S. EL. Minor W.S. EL. Major WQ H1 H2 V1 V2 Routing Order #1 (Standard) V1 W.S. EL. WQ W.S. EL. Design Storm WQ H1 Routing Order #3 (Single Stage) Routing Order #4 V2 V1 H1 WQ W.S. EL. Major W.S. EL. Minor W.S. EL. WQ W.S. EL. Emergency Spillway Emergency Overflow into Pipe- H2 V2 H1 WQ W.S. EL. Major W.S. EL. Minor W.S. EL. WQ V1 Routing Order #2 Copy of UD-Detention_v2.35 - DETENTION POND.xls, Outlet 6/30/2015, 4:16 PM #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Override Area Row 1 Override Area Row 2 Override Area Row 3 Override Area Row 4 Override Area Row 5 Override Area Row 6 Override Area Row 7 Override Area Row 8 Override Area Row 9 Override Area Row 10 Override Area Row 11 Override Area Row 12 Override Area Row 13 Override Area Row 14 Override Area Row 15 Override Area Row 16 Override Area Row 17 Override Area Row 18 Override Area Row 19 Override Area Row 20 Override Area Row 21 Override Area Row 22 Override Area Row 23 Override Area Row 24 Central Elevations of Rows of Holes in feet Collection Capacity for Each Row of Holes in cfs STAGE-DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET Affinity Fort Collins PDP EX1 Copy of UD-Detention_v2.35 - DETENTION POND.xls, WQCV 6/30/2015, 4:16 PM #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A STAGE-STORAGE SIZING FOR DETENTION BASINS Affinity Fort Collins PDP Check Basin Shape EX1 Copy of UD-Detention_v2.35 - DETENTION POND.xls, Basin 6/30/2015, 4:16 PM 110 0.53 0.273 0.56 0.62 0.094 0.178 110 1.87 1.462 0.56 0.62 0.094 1.367 115 0.52 0.276 0.56 0.62 0.098 0.178 115 1.81 1.480 0.56 0.62 0.098 1.382 120 0.50 0.279 0.55 0.62 0.102 0.177 120 1.75 1.497 0.55 0.62 0.102 1.395 125 0.49 0.282 0.55 0.61 0.106 0.177 125 1.70 1.514 0.55 0.61 0.106 1.408 130 0.47 0.285 0.55 0.61 0.110 0.176 130 1.65 1.530 0.55 0.61 0.110 1.420 135 0.46 0.288 0.55 0.61 0.113 0.175 135 1.61 1.545 0.55 0.61 0.113 1.432 140 0.45 0.291 0.55 0.61 0.117 0.174 140 1.56 1.560 0.55 0.61 0.117 1.443 145 0.44 0.294 0.55 0.61 0.121 0.173 145 1.52 1.575 0.55 0.61 0.121 1.453 150 0.43 0.296 0.54 0.60 0.125 0.171 150 1.49 1.589 0.54 0.60 0.125 1.464 155 0.42 0.299 0.54 0.60 0.129 0.170 155 1.45 1.602 0.54 0.60 0.129 1.473 160 0.41 0.301 0.54 0.60 0.133 0.169 160 1.42 1.615 0.54 0.60 0.133 1.483 165 0.40 0.304 0.54 0.60 0.136 0.167 165 1.39 1.628 0.54 0.60 0.136 1.492 170 0.39 0.306 0.54 0.60 0.140 0.166 170 1.35 1.641 0.54 0.60 0.140 1.500 175 0.38 0.308 0.54 0.60 0.144 0.164 175 1.33 1.653 0.54 0.60 0.144 1.509 180 0.37 0.311 0.54 0.60 0.148 0.163 180 1.30 1.665 0.54 0.60 0.148 1.517 185 0.36 0.313 0.54 0.60 0.152 0.161 185 1.27 1.676 0.54 0.60 0.152 1.524 190 0.36 0.315 0.53 0.59 0.156 0.159 190 1.25 1.687 0.53 0.59 0.156 1.532 195 0.35 0.317 0.53 0.59 0.159 0.157 195 1.22 1.698 0.53 0.59 0.159 1.539 200 0.34 0.319 0.53 0.59 0.163 0.156 200 1.20 1.709 0.53 0.59 0.163 1.546 205 0.34 0.321 0.53 0.59 0.167 0.154 205 1.18 1.720 0.53 0.59 0.167 1.552 210 0.33 0.323 0.53 0.59 0.171 0.152 210 1.16 1.730 0.53 0.59 0.171 1.559 215 0.33 0.325 0.53 0.59 0.175 0.150 215 1.14 1.740 0.53 0.59 0.175 1.565 220 0.32 0.326 0.53 0.59 0.179 0.148 220 1.12 1.750 0.53 0.59 0.179 1.571 225 0.31 0.328 0.53 0.59 0.182 0.146 225 1.10 1.759 0.53 0.59 0.182 1.577 230 0.31 0.330 0.53 0.59 0.186 0.144 230 1.08 1.769 0.53 0.59 0.186 1.583 235 0.30 0.332 0.53 0.59 0.190 0.142 235 1.06 1.778 0.53 0.59 0.190 1.588 240 0.30 0.333 0.53 0.59 0.194 0.140 240 1.05 1.787 0.53 0.59 0.194 1.593 245 0.30 0.335 0.53 0.59 0.198 0.137 245 1.03 1.796 0.53 0.59 0.198 1.598 250 0.29 0.337 0.53 0.59 0.202 0.135 250 1.01 1.805 0.53 0.59 0.202 1.603 255 0.29 0.338 0.53 0.58 0.205 0.133 255 1.00 1.814 0.53 0.58 0.205 1.608 260 0.28 0.340 0.53 0.58 0.209 0.131 260 0.98 1.822 0.53 0.58 0.209 1.613 265 0.28 0.342 0.52 0.58 0.213 0.128 265 0.97 1.831 0.52 0.58 0.213 1.617 270 0.27 0.343 0.52 0.58 0.217 0.126 270 0.96 1.839 0.52 0.58 0.217 1.622 275 0.27 0.345 0.52 0.58 0.221 0.124 275 0.94 1.847 0.52 0.58 0.221 1.626 280 0.27 0.346 0.52 0.58 0.225 0.121 280 0.93 1.855 0.52 0.58 0.225 1.630 285 0.26 0.348 0.52 0.58 0.228 0.119 285 0.92 1.863 0.52 0.58 0.228 1.634 290 0.26 0.349 0.52 0.58 0.232 0.117 290 0.91 1.870 0.52 0.58 0.232 1.638 295 0.26 0.350 0.52 0.58 0.236 0.114 295 0.89 1.878 0.52 0.58 0.236 1.642 300 0.25 0.352 0.52 0.58 0.240 0.112 300 0.88 1.885 0.52 0.58 0.240 1.645 305 0.25 0.353 0.52 0.58 0.244 0.109 305 0.87 1.893 0.52 0.58 0.244 1.649 Mod. FAA Minor Storage Volume (cubic ft.) = 7,794 Mod. FAA Major Storage Volume (cubic ft.) = 71,828 Mod. FAA Minor Storage Volume (acre-ft.) = 0.1789 Mod. FAA Major Storage Volume (acre-ft.) = 1.6489 Determination of MAJOR Detention Volume Using Modified FAA Method (For catchments less than 160 acres only. For larger catchments, use hydrograph routing method) (NOTE: for catchments larger than 90 acres, CUHP hydrograph and routing are recommended) UDFCD DETENTION BASIN VOLUME ESTIMATING WORKBOOK Version 2.35, Released January 2015 Determination of MINOR Detention Volume Using Modified FAA Method DETENTION VOLUME BY THE MODIFIED FAA METHOD Affinity Fort Collins PDP EX1 Copy of UD-Detention_v2.35 - DETENTION POND.xls, Modified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²$SU  7KHRUWKRSKRWRRURWKHUEDVHPDSRQZKLFKWKHVRLOOLQHVZHUH FRPSLOHGDQGGLJLWL]HGSUREDEO\GLIIHUVIURPWKHEDFNJURXQG LPDJHU\GLVSOD\HGRQWKHVHPDSV$VDUHVXOWVRPHPLQRUVKLIWLQJ RIPDSXQLWERXQGDULHVPD\EHHYLGHQW &XVWRP6RLO5HVRXUFH5HSRUW  VKHHW OLVWHGEHORZ 6RLO6XUYH\$UHD /DULPHU&RXQW\$UHD&RORUDGR 6XUYH\$UHD'DWD 9HUVLRQ6HS 6RLOPDSXQLWVDUHODEHOHG DVVSDFHDOORZV IRUPDSVFDOHV RUODUJHU 'DWH V DHULDOLPDJHVZHUHSKRWRJUDSKHG $SU²$SU  7KHRUWKRSKRWRRURWKHUEDVHPDSRQZKLFKWKHVRLOOLQHVZHUH FRPSLOHGDQGGLJLWL]HGSUREDEO\GLIIHUVIURPWKHEDFNJURXQG LPDJHU\GLVSOD\HGRQWKHVHPDSV$VDUHVXOWVRPHPLQRUVKLIWLQJ RIPDSXQLWERXQGDULHVPD\EHHYLGHQW &XVWRP6RLO5HVRXUFH5HSRUW  VKHHW