HomeMy WebLinkAboutFOOTHILLS MALL MULTI-FAMILY - MAJOR AMENDMENT - MJA150002 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSREVISIONS
NO.
REV.
DATE REVISIONS DESCRIPTION
project no.:
approved by:
checked by:
drawn by:
drawing no.:
QA/QC by:
date:
SHEET
TEL 970.461.7733 www.olssonassociates.com
5285 McWhinney Boulevard, Suite 160
Loveland, CO 80538
OLSSON ASSOCIATES ASSUMES
NO RESPONSIBILITY FOR
EXISTING UTILITY LOCATIONS
(HORIZONTAL OR VERTICAL). THE
EXISTING UTILITIES SHOWN ON
THIS DRAWING HAVE BEEN
PLOTTED FROM THE BEST
AVAILABLE INFORMATION. IT IS
HOWEVER THE RESPONSIBILITY
OF THE CONTRACTOR TO FIELD
VERIFY THE LOCATION OF ALL
UTILITIES PRIOR TO THE
COMMENCEMENT OF ANY
CONSTRUCTION ACTIVITIES.
NOTE
THIS DOCUMENT HAS BEEN
RELEASED BY OLSSON
ASSOCIATES ONLY FOR REVIEW
BY REGULATORY AGENCIES AND
OTHER PROFESSIONALS, AND IS
SUBJECT TO CHANGE. THIS
DOCUMENT IS NOT TO BE USED
FOR CONSTRUCTION.
CALL 811 SEVENTY-TWO HOURS
PRIOR TO DIGGING, GRADING OR
EXCAVATING FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES
COVER SHEET R
FORT COLLINS, COLORADO 2015
04/24/2015
015-0720
FOOTHILLS MALL REDEVELOPMENT
DH
150720_TTL01.dwg
DH
JG
C1.0
A
04/24/2015
STANFORD RD
STANFORD RD
REVISIONS
NO.
REV.
DATE REVISIONS DESCRIPTION
project no.:
approved by:
checked by:
drawn by:
drawing no.:
QA/QC by:
date:
SHEET
TEL 970.461.7733 www.olssonassociates.com
5285 McWhinney Boulevard, Suite 160
Loveland, CO 80538
OLSSON ASSOCIATES ASSUMES
NO RESPONSIBILITY FOR
EXISTING UTILITY LOCATIONS
(HORIZONTAL OR VERTICAL). THE
EXISTING UTILITIES SHOWN ON
THIS DRAWING HAVE BEEN
PLOTTED FROM THE BEST
AVAILABLE INFORMATION. IT IS
HOWEVER THE RESPONSIBILITY
OF THE CONTRACTOR TO FIELD
VERIFY THE LOCATION OF ALL
UTILITIES PRIOR TO THE
COMMENCEMENT OF ANY
CONSTRUCTION ACTIVITIES.
NOTE
THIS DOCUMENT HAS BEEN
RELEASED BY OLSSON
ASSOCIATES ONLY FOR REVIEW
BY REGULATORY AGENCIES AND
OTHER PROFESSIONALS, AND IS
SUBJECT TO CHANGE. THIS
DOCUMENT IS NOT TO BE USED
FOR CONSTRUCTION.
CALL 811 SEVENTY-TWO HOURS
PRIOR TO DIGGING, GRADING OR
EXCAVATING FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES
OVERALL GRADING PLAN R
FORT COLLINS, COLORADO 2015
04/24/2015
015-0720
FOOTHILLS MALL REDEVELOPMENT
DH
150720_GRD01.dwg
DH
JG
C6.0
A
REVISIONS
NO.
REV.
DATE REVISIONS DESCRIPTION
project no.:
approved by:
checked by:
drawn by:
drawing no.:
QA/QC by:
date:
SHEET
TEL 970.461.7733 www.olssonassociates.com
5285 McWhinney Boulevard, Suite 160
Loveland, CO 80538
OLSSON ASSOCIATES ASSUMES
NO RESPONSIBILITY FOR
EXISTING UTILITY LOCATIONS
(HORIZONTAL OR VERTICAL). THE
EXISTING UTILITIES SHOWN ON
THIS DRAWING HAVE BEEN
PLOTTED FROM THE BEST
AVAILABLE INFORMATION. IT IS
HOWEVER THE RESPONSIBILITY
OF THE CONTRACTOR TO FIELD
VERIFY THE LOCATION OF ALL
UTILITIES PRIOR TO THE
COMMENCEMENT OF ANY
CONSTRUCTION ACTIVITIES.
NOTE
THIS DOCUMENT HAS BEEN
RELEASED BY OLSSON
ASSOCIATES ONLY FOR REVIEW
BY REGULATORY AGENCIES AND
OTHER PROFESSIONALS, AND IS
SUBJECT TO CHANGE. THIS
DOCUMENT IS NOT TO BE USED
FOR CONSTRUCTION.
CALL 811 SEVENTY-TWO HOURS
PRIOR TO DIGGING, GRADING OR
EXCAVATING FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES
GRADING PLAN R
FORT COLLINS, COLORADO 2015
04/24/2015
015-0720
FOOTHILLS MALL REDEVELOPMENT
DH
150720_GRD02.dwg
DH
JG
C6.1
A
04/24/2015
REVISIONS
NO.
REV.
DATE REVISIONS DESCRIPTION
project no.:
approved by:
checked by:
drawn by:
drawing no.:
QA/QC by:
date:
SHEET
TEL 970.461.7733 www.olssonassociates.com
5285 McWhinney Boulevard, Suite 160
Loveland, CO 80538
OLSSON ASSOCIATES ASSUMES
NO RESPONSIBILITY FOR
EXISTING UTILITY LOCATIONS
(HORIZONTAL OR VERTICAL). THE
EXISTING UTILITIES SHOWN ON
THIS DRAWING HAVE BEEN
PLOTTED FROM THE BEST
AVAILABLE INFORMATION. IT IS
HOWEVER THE RESPONSIBILITY
OF THE CONTRACTOR TO FIELD
VERIFY THE LOCATION OF ALL
UTILITIES PRIOR TO THE
COMMENCEMENT OF ANY
CONSTRUCTION ACTIVITIES.
NOTE
THIS DOCUMENT HAS BEEN
RELEASED BY OLSSON
ASSOCIATES ONLY FOR REVIEW
BY REGULATORY AGENCIES AND
OTHER PROFESSIONALS, AND IS
SUBJECT TO CHANGE. THIS
DOCUMENT IS NOT TO BE USED
FOR CONSTRUCTION.
CALL 811 SEVENTY-TWO HOURS
PRIOR TO DIGGING, GRADING OR
EXCAVATING FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES
GRADING PLAN R
FORT COLLINS, COLORADO 2015
04/24/2015
015-0720
FOOTHILLS MALL REDEVELOPMENT
DH
150720_GRD02.dwg
DH
JG
C6.2
A
04/24/2015
T T
BUILDING 5
TYPE D3
BUILDING 6
TYPE C3
BUILDING 7
TYPE E2
BUILDING 8
TYPE D2
STANFORD ROAD
RG-33.0
REVISIONS
NO.
REV.
DATE REVISIONS DESCRIPTION
project no.:
approved by:
checked by:
drawn by:
drawing no.:
QA/QC by:
date:
SHEET
TEL 970.461.7733 www.olssonassociates.com
5285 McWhinney Boulevard, Suite 160
Loveland, CO 80538
OLSSON ASSOCIATES ASSUMES
NO RESPONSIBILITY FOR
EXISTING UTILITY LOCATIONS
(HORIZONTAL OR VERTICAL). THE
EXISTING UTILITIES SHOWN ON
THIS DRAWING HAVE BEEN
PLOTTED FROM THE BEST
AVAILABLE INFORMATION. IT IS
HOWEVER THE RESPONSIBILITY
OF THE CONTRACTOR TO FIELD
VERIFY THE LOCATION OF ALL
UTILITIES PRIOR TO THE
COMMENCEMENT OF ANY
CONSTRUCTION ACTIVITIES.
NOTE
THIS DOCUMENT HAS BEEN
RELEASED BY OLSSON
ASSOCIATES ONLY FOR REVIEW
BY REGULATORY AGENCIES AND
OTHER PROFESSIONALS, AND IS
SUBJECT TO CHANGE. THIS
DOCUMENT IS NOT TO BE USED
FOR CONSTRUCTION.
CALL 811 SEVENTY-TWO HOURS
PRIOR TO DIGGING, GRADING OR
EXCAVATING FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES
GRADING PLAN R
FORT COLLINS, COLORADO 2015
04/24/2015
015-0720
FOOTHILLS MALL REDEVELOPMENT
DH
150720_GRD03.dwg
T T
T
BUILDING 1
TYPE D3
BUILDING 2
TYPE C3
BUILDING 3
TYPE E2
BUILDING 4
TYPE D2
REVISIONS
NO.
REV.
DATE REVISIONS DESCRIPTION
project no.:
approved by:
checked by:
drawn by:
drawing no.:
QA/QC by:
date:
SHEET
TEL 970.461.7733 www.olssonassociates.com
5285 McWhinney Boulevard, Suite 160
Loveland, CO 80538
OLSSON ASSOCIATES ASSUMES
NO RESPONSIBILITY FOR
EXISTING UTILITY LOCATIONS
(HORIZONTAL OR VERTICAL). THE
EXISTING UTILITIES SHOWN ON
THIS DRAWING HAVE BEEN
PLOTTED FROM THE BEST
AVAILABLE INFORMATION. IT IS
HOWEVER THE RESPONSIBILITY
OF THE CONTRACTOR TO FIELD
VERIFY THE LOCATION OF ALL
UTILITIES PRIOR TO THE
COMMENCEMENT OF ANY
CONSTRUCTION ACTIVITIES.
NOTE
THIS DOCUMENT HAS BEEN
RELEASED BY OLSSON
ASSOCIATES ONLY FOR REVIEW
BY REGULATORY AGENCIES AND
OTHER PROFESSIONALS, AND IS
SUBJECT TO CHANGE. THIS
DOCUMENT IS NOT TO BE USED
FOR CONSTRUCTION.
CALL 811 SEVENTY-TWO HOURS
PRIOR TO DIGGING, GRADING OR
EXCAVATING FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES
GRADING PLAN R
FORT COLLINS, COLORADO 2015
04/24/2015
015-0720
FOOTHILLS MALL REDEVELOPMENT
DH
150720_GRD03.dwg
DH
STANFORD RD
STANFORD RD
UTILITY PLAN
REVISIONS
NO.
REV.
DATE REVISIONS DESCRIPTION
project no.:
approved by:
checked by:
drawn by:
drawing no.:
QA/QC by:
date:
SHEET
TEL 970.461.7733 www.olssonassociates.com
5285 McWhinney Boulevard, Suite 160
Loveland, CO 80538
OLSSON ASSOCIATES ASSUMES
NO RESPONSIBILITY FOR
EXISTING UTILITY LOCATIONS
(HORIZONTAL OR VERTICAL). THE
EXISTING UTILITIES SHOWN ON
THIS DRAWING HAVE BEEN
PLOTTED FROM THE BEST
AVAILABLE INFORMATION. IT IS
HOWEVER THE RESPONSIBILITY
OF THE CONTRACTOR TO FIELD
VERIFY THE LOCATION OF ALL
UTILITIES PRIOR TO THE
COMMENCEMENT OF ANY
CONSTRUCTION ACTIVITIES.
NOTE
THIS DOCUMENT HAS BEEN
RELEASED BY OLSSON
ASSOCIATES ONLY FOR REVIEW
BY REGULATORY AGENCIES AND
OTHER PROFESSIONALS, AND IS
SUBJECT TO CHANGE. THIS
DOCUMENT IS NOT TO BE USED
FOR CONSTRUCTION.
CALL 811 SEVENTY-TWO HOURS
PRIOR TO DIGGING, GRADING OR
EXCAVATING FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES
OVERALL UTILITY PLAN R
FORT COLLINS, COLORADO 2015
04/24/2015
015-0720
FOOTHILLS MALL REDEVELOPMENT
DH
150720_UTL01.dwg
DH
JG
C8.0
A
REVISIONS
NO.
REV.
DATE REVISIONS DESCRIPTION
project no.:
approved by:
checked by:
drawn by:
drawing no.:
QA/QC by:
date:
SHEET
TEL 970.461.7733 www.olssonassociates.com
5285 McWhinney Boulevard, Suite 160
Loveland, CO 80538
OLSSON ASSOCIATES ASSUMES
NO RESPONSIBILITY FOR
EXISTING UTILITY LOCATIONS
(HORIZONTAL OR VERTICAL). THE
EXISTING UTILITIES SHOWN ON
THIS DRAWING HAVE BEEN
PLOTTED FROM THE BEST
AVAILABLE INFORMATION. IT IS
HOWEVER THE RESPONSIBILITY
OF THE CONTRACTOR TO FIELD
VERIFY THE LOCATION OF ALL
UTILITIES PRIOR TO THE
COMMENCEMENT OF ANY
CONSTRUCTION ACTIVITIES.
NOTE
THIS DOCUMENT HAS BEEN
RELEASED BY OLSSON
ASSOCIATES ONLY FOR REVIEW
BY REGULATORY AGENCIES AND
OTHER PROFESSIONALS, AND IS
SUBJECT TO CHANGE. THIS
DOCUMENT IS NOT TO BE USED
FOR CONSTRUCTION.
CALL 811 SEVENTY-TWO HOURS
PRIOR TO DIGGING, GRADING OR
EXCAVATING FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES
UTILITY PLAN R
FORT COLLINS, COLORADO 2015
04/24/2015
015-0720
FOOTHILLS MALL REDEVELOPMENT
DH
150720_UTL02.dwg
DH
JG
C8.1
A
04/24/2015
REVISIONS
NO.
REV.
DATE REVISIONS DESCRIPTION
project no.:
approved by:
checked by:
drawn by:
drawing no.:
QA/QC by:
date:
SHEET
TEL 970.461.7733 www.olssonassociates.com
5285 McWhinney Boulevard, Suite 160
Loveland, CO 80538
OLSSON ASSOCIATES ASSUMES
NO RESPONSIBILITY FOR
EXISTING UTILITY LOCATIONS
(HORIZONTAL OR VERTICAL). THE
EXISTING UTILITIES SHOWN ON
THIS DRAWING HAVE BEEN
PLOTTED FROM THE BEST
AVAILABLE INFORMATION. IT IS
HOWEVER THE RESPONSIBILITY
OF THE CONTRACTOR TO FIELD
VERIFY THE LOCATION OF ALL
UTILITIES PRIOR TO THE
COMMENCEMENT OF ANY
CONSTRUCTION ACTIVITIES.
NOTE
THIS DOCUMENT HAS BEEN
RELEASED BY OLSSON
ASSOCIATES ONLY FOR REVIEW
BY REGULATORY AGENCIES AND
OTHER PROFESSIONALS, AND IS
SUBJECT TO CHANGE. THIS
DOCUMENT IS NOT TO BE USED
FOR CONSTRUCTION.
CALL 811 SEVENTY-TWO HOURS
PRIOR TO DIGGING, GRADING OR
EXCAVATING FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES
UTILITY PLAN R
FORT COLLINS, COLORADO 2015
04/24/2015
015-0720
FOOTHILLS MALL REDEVELOPMENT
DH
150720_UTL02.dwg
DH
JG
C8.2
A
04/24/2015
193.7 L.F. 8"
WATER MAIN
29.7 L.F. 1.5"
WATER SERVICE
29.7 L.F. 4"
FIRE SERVICE
11.6 L.F.
OF 6" SANITARY
SEWER SERVICE
11.4 L.F.
OF 6" SANITARY
SEWER SERVICE
125.3 L.F.
OF 18" STORM
30.8 L.F. 1.5"
WATER SERVICE
30.8 L.F. 1.5"
WATER SERVICE
30.8 L.F. 4"
FIRE SERVICE 30.8 L.F. 4"
FIRE SERVICE
AREA INLET TYP.
AREA INLET TYP.
SANITARY MANHOLE
STORM MANHOLE
1.5" SERVICE
METER PIT
1.5" SERVICE
METER PIT
1.5" SERVICE
METER PIT
BUILDING 5
TYPE D3
BUILDING 6
TYPE C3
BUILDING 7
TYPE E2
BUILDING 8
TYPE D2
STANFORD ROAD
CUT AND PATCH
STREET
43.9 L.F.
OF 12" STORM
35.8 L.F.
OF 12" STORM
33.1 L.F.
OF 12" STORM
42.8 L.F.
OF 12" STORM
39.1 L.F.
OF 12" STORM
93.4 L.F.
OF 18" STORM
43.7 L.F.
OF 12" STORM
35.7 L.F.
OF 12" STORM
35.7 L.F.
OF 12" STORM
32.2 L.F. 1.5"
WATER SERVICE
44.2 L.F. 1.5"
WATER SERVICE
42.9 L.F. 1.5"
WATER SERVICE
157.7 L.F. 8"
WATER MAIN
52.7 L.F. 8"
WATER MAIN
32.3 L.F. 4"
FIRE SERVICE
20.0 L.F.
OF 6" SANITARY
SEWER SERVICE
20.0 L.F.
OF 6" SANITARY
SEWER SERVICE
20.0 L.F.
OF 6" SANITARY
SEWER SERVICE
20.0 L.F.
OF 6" SANITARY
SEWER SERVICE
107.0 L.F.
OF 8" SANITARY
SEWER MAIN
123.5 L.F.
OF 18" STORM
AREA INLET TYP.
AREA INLET TYP.
SANITARY MANHOLE
SANITARY MANHOLE
STORM MANHOLE STORM MANHOLE STORM MANHOLE
STORM MANHOLE
1.5" SERVICE PROPOSED FIRE HYDRANT
METER PIT
1.5" SERVICE
METER PIT
1.5" SERVICE
METER PIT
AREA INLET TYP.
BUILDING 1
TYPE D3
BUILDING 2
TYPE C3
BUILDING 3
TYPE E2
BUILDING 4
TYPE D2
35.7 L.F.
OF 12" STORM
43.7 L.F.
OF 12" STORM
35.7 L.F.
OF 12" STORM
35.7 L.F.
OF 12" STORM
39.1 L.F.
OF 12" STORM
STANFORD RD
STANFORD RD
REVISIONS
NO.
REV.
DATE REVISIONS DESCRIPTION
project no.:
approved by:
checked by:
drawn by:
drawing no.:
QA/QC by:
date:
SHEET
TEL 970.461.7733 www.olssonassociates.com
5285 McWhinney Boulevard, Suite 160
Loveland, CO 80538
OLSSON ASSOCIATES ASSUMES
NO RESPONSIBILITY FOR
EXISTING UTILITY LOCATIONS
(HORIZONTAL OR VERTICAL). THE
EXISTING UTILITIES SHOWN ON
THIS DRAWING HAVE BEEN
PLOTTED FROM THE BEST
AVAILABLE INFORMATION. IT IS
HOWEVER THE RESPONSIBILITY
OF THE CONTRACTOR TO FIELD
VERIFY THE LOCATION OF ALL
UTILITIES PRIOR TO THE
COMMENCEMENT OF ANY
CONSTRUCTION ACTIVITIES.
NOTE
THIS DOCUMENT HAS BEEN
RELEASED BY OLSSON
ASSOCIATES ONLY FOR REVIEW
BY REGULATORY AGENCIES AND
OTHER PROFESSIONALS, AND IS
SUBJECT TO CHANGE. THIS
DOCUMENT IS NOT TO BE USED
FOR CONSTRUCTION.
CALL 811 SEVENTY-TWO HOURS
PRIOR TO DIGGING, GRADING OR
EXCAVATING FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES
OVERALL PAVING PLAN R
FORT COLLINS, COLORADO 2015
04/24/2015
015-0720
FOOTHILLS MALL REDEVELOPMENT
DH
150720_PAV01.dwg
DH
JG
C14.0
A
REVISIONS
NO.
REV.
DATE REVISIONS DESCRIPTION
project no.:
approved by:
checked by:
drawn by:
drawing no.:
QA/QC by:
date:
SHEET
TEL 970.461.7733 www.olssonassociates.com
5285 McWhinney Boulevard, Suite 160
Loveland, CO 80538
OLSSON ASSOCIATES ASSUMES
NO RESPONSIBILITY FOR
EXISTING UTILITY LOCATIONS
(HORIZONTAL OR VERTICAL). THE
EXISTING UTILITIES SHOWN ON
THIS DRAWING HAVE BEEN
PLOTTED FROM THE BEST
AVAILABLE INFORMATION. IT IS
HOWEVER THE RESPONSIBILITY
OF THE CONTRACTOR TO FIELD
VERIFY THE LOCATION OF ALL
UTILITIES PRIOR TO THE
COMMENCEMENT OF ANY
CONSTRUCTION ACTIVITIES.
NOTE
THIS DOCUMENT HAS BEEN
RELEASED BY OLSSON
ASSOCIATES ONLY FOR REVIEW
BY REGULATORY AGENCIES AND
OTHER PROFESSIONALS, AND IS
SUBJECT TO CHANGE. THIS
DOCUMENT IS NOT TO BE USED
FOR CONSTRUCTION.
CALL 811 SEVENTY-TWO HOURS
PRIOR TO DIGGING, GRADING OR
EXCAVATING FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES
PAVING PLAN R
FORT COLLINS, COLORADO 2015
04/24/2015
015-0720
FOOTHILLS MALL REDEVELOPMENT
DH
150720_PAV02.dwg
DH
JG
C14.1
A
04/24/2015
REVISIONS
NO.
REV.
DATE REVISIONS DESCRIPTION
project no.:
approved by:
checked by:
drawn by:
drawing no.:
QA/QC by:
date:
SHEET
TEL 970.461.7733 www.olssonassociates.com
5285 McWhinney Boulevard, Suite 160
Loveland, CO 80538
OLSSON ASSOCIATES ASSUMES
NO RESPONSIBILITY FOR
EXISTING UTILITY LOCATIONS
(HORIZONTAL OR VERTICAL). THE
EXISTING UTILITIES SHOWN ON
THIS DRAWING HAVE BEEN
PLOTTED FROM THE BEST
AVAILABLE INFORMATION. IT IS
HOWEVER THE RESPONSIBILITY
OF THE CONTRACTOR TO FIELD
VERIFY THE LOCATION OF ALL
UTILITIES PRIOR TO THE
COMMENCEMENT OF ANY
CONSTRUCTION ACTIVITIES.
NOTE
THIS DOCUMENT HAS BEEN
RELEASED BY OLSSON
ASSOCIATES ONLY FOR REVIEW
BY REGULATORY AGENCIES AND
OTHER PROFESSIONALS, AND IS
SUBJECT TO CHANGE. THIS
DOCUMENT IS NOT TO BE USED
FOR CONSTRUCTION.
CALL 811 SEVENTY-TWO HOURS
PRIOR TO DIGGING, GRADING OR
EXCAVATING FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES
PAVING PLAN R
FORT COLLINS, COLORADO 2015
04/24/2015
015-0720
FOOTHILLS MALL REDEVELOPMENT
DH
150720_PAV02.dwg
DH
JG
C14.2
A
04/24/2015
KEYNOTES
1. INSTALL PAVEMENT. SEE PAVEMENT TABLE.
2. INSTALL CONCRETE SIDEWALK WIDTH = 5.0'.
3. INSTALL CONCRETE SIDEWALK WIDTH = 6.0'.
4. HANDICAP ACCESSIBLE LOADING ZONE, INSTALL HC STRIPING PER MUTCD STANDARDS.
5. HANDICAP RAMP.
6. INSTALL HANDICAP PARKING SIGN.
7. TRASH ENCLOSURE.
8. INSTALL PARKING STRIPING, TYPICAL.
9. INSTALL BICYCLE RACK.
10. INSTALL STOP SIGN.
T T
24.0'
17.0'
(TYP)
24.1'
BUILDING 5
TYPE D3
BUILDING 6
TYPE C3
BUILDING 7
TYPE E2
BUILDING 8
TYPE D2
STANFORD ROAD
108.0' 9.0' 81.0' 51.4' 108.0' 66.1'
18.0' 62.0' 42.0' 62.0' 51.4' 62.0' 45.1' 62.0' 5.0'
25.0' 25.0'
1
1
1
1
2 2 2
2
4
9 9
22.3'
22.0'
5.0'
52.3'
5.0'
43.1'
7
7
8 8 8
9 9
6
REVISIONS
NO.
REV.
DATE REVISIONS DESCRIPTION
project no.:
approved by:
checked by:
drawn by:
drawing no.:
QA/QC by:
date:
SHEET
TEL 970.461.7733 www.olssonassociates.com
KEYNOTES
1. INSTALL PAVEMENT. SEE PAVEMENT TABLE.
2. INSTALL CONCRETE SIDEWALK WIDTH = 5.0'.
3. INSTALL CONCRETE SIDEWALK WIDTH = 6.0'.
4. HANDICAP ACCESSIBLE LOADING ZONE, INSTALL HC STRIPING PER MUTCD STANDARDS.
5. HANDICAP RAMP.
6. INSTALL HANDICAP PARKING SIGN.
7. TRASH ENCLOSURE.
8. INSTALL PARKING STRIPING, TYPICAL.
9. INSTALL BICYCLE RACK.
10. INSTALL STOP SIGN.
T T
24.0'
17.0'
(TYP)
24.2'
BUILDING 1
TYPE D3
BUILDING 2
TYPE C3
BUILDING 3
TYPE E2
BUILDING 4
TYPE D2
1
19.0' 62.0' 42.0' 62.0' 55.0' 62.0' 45.1' 62.0' 18.0'
5.0' 90.0' 9.0' 81.0' 55.0' 81.0' 9.0' 108.0'
25.0' 25.0'
1
1
1
2 2
2
2
4
9 9
22.3'
22.0'
5.0'
52.3'
5.0'
43.1'
7
8 8 7 8
9
6
9
REVISIONS
NO.
REV.
DATE REVISIONS DESCRIPTION
project no.:
approved by:
checked by:
drawn by:
drawing no.:
QA/QC by:
date:
SHEET
TEL 970.461.7733 www.olssonassociates.com
5285 McWhinney Boulevard, Suite 160
Loveland, CO 80538
OLSSON ASSOCIATES ASSUMES
NO RESPONSIBILITY FOR
EXISTING UTILITY LOCATIONS
(HORIZONTAL OR VERTICAL). THE
EXISTING UTILITIES SHOWN ON
THIS DRAWING HAVE BEEN
PLOTTED FROM THE BEST
AVAILABLE INFORMATION. IT IS
HOWEVER THE RESPONSIBILITY
OF THE CONTRACTOR TO FIELD
VERIFY THE LOCATION OF ALL
UTILITIES PRIOR TO THE
COMMENCEMENT OF ANY
CONSTRUCTION ACTIVITIES.
NOTE
THIS DOCUMENT HAS BEEN
RELEASED BY OLSSON
ASSOCIATES ONLY FOR REVIEW
BY REGULATORY AGENCIES AND
OTHER PROFESSIONALS, AND IS
SUBJECT TO CHANGE. THIS
DOCUMENT IS NOT TO BE USED
FOR CONSTRUCTION.
CALL 811 SEVENTY-TWO HOURS
PRIOR TO DIGGING, GRADING OR
EXCAVATING FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES
PAVING PLAN R
FORT COLLINS, COLORADO 2015
04/24/2015
015-0720
FOOTHILLS MALL REDEVELOPMENT
DH
150720_PAV03.dwg
DH
JG
C14.4
A
04/24/2015
1ST MAJOR AMENDMENT SUBMITTAL
MAJOR AMENDMENT
LOT 3 WEST
DH
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
DATE
DATE
DATE
DATE
DATE
DATE
CITY ENGINEER
WATER AND WASTEWATER UTILITY
STORMWATER UTILITY
PARKS AND RECREATION
TRAFFIC ENGINEER
SEE SHEET C14.3
MATCHLINE
Recommended Minimum Pavement Sections LOT 3 WEST
Location
Full Depth
Asphalt
(inches Asphalt)
Composite
Section
(inches Asphalt
/ inches
Aggregate
Base)
Rigid
Section
(inches
Concrete)
Private Parking
Lot 6 4.5 / 6 5
Private Drive
Lanes and
Heavy Truck
Traffic
6.5 5 / 6 6
5285 McWhinney Boulevard, Suite 160
Loveland, CO 80538
OLSSON ASSOCIATES ASSUMES
NO RESPONSIBILITY FOR
EXISTING UTILITY LOCATIONS
(HORIZONTAL OR VERTICAL). THE
EXISTING UTILITIES SHOWN ON
THIS DRAWING HAVE BEEN
PLOTTED FROM THE BEST
AVAILABLE INFORMATION. IT IS
HOWEVER THE RESPONSIBILITY
OF THE CONTRACTOR TO FIELD
VERIFY THE LOCATION OF ALL
UTILITIES PRIOR TO THE
COMMENCEMENT OF ANY
CONSTRUCTION ACTIVITIES.
NOTE
THIS DOCUMENT HAS BEEN
RELEASED BY OLSSON
ASSOCIATES ONLY FOR REVIEW
BY REGULATORY AGENCIES AND
OTHER PROFESSIONALS, AND IS
SUBJECT TO CHANGE. THIS
DOCUMENT IS NOT TO BE USED
FOR CONSTRUCTION.
CALL 811 SEVENTY-TWO HOURS
PRIOR TO DIGGING, GRADING OR
EXCAVATING FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES
PAVING PLAN R
FORT COLLINS, COLORADO 2015
04/24/2015
015-0720
FOOTHILLS MALL REDEVELOPMENT
DH
150720_PAV03.dwg
DH
JG
C14.3
A
04/24/2015
1ST MAJOR AMENDMENT SUBMITTAL
MAJOR AMENDMENT
LOT 3 EAST
DH
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
DATE
DATE
DATE
DATE
DATE
DATE
CITY ENGINEER
WATER AND WASTEWATER UTILITY
STORMWATER UTILITY
PARKS AND RECREATION
TRAFFIC ENGINEER
MATCHLINE
SEE SHEET C14.4
LOT 3 EAST
Recommended Minimum Pavement Sections
Location
Full Depth
Asphalt
(inches Asphalt)
Composite
Section
(inches Asphalt
/ inches
Aggregate
Base)
Rigid
Section
(inches
Concrete)
Private Parking
Lot 6 4.5 / 6 5
Private Drive
Lanes and
Heavy Truck
Traffic
6.5 5 / 6 6
1ST MAJOR AMENDMENT SUBMITTAL
MAJOR AMENDMENT
LOT 4
DH
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
DATE
DATE
DATE
DATE
DATE
DATE
CITY ENGINEER
WATER AND WASTEWATER UTILITY
STORMWATER UTILITY
PARKS AND RECREATION
TRAFFIC ENGINEER
LOT 4
Recommended Minimum Pavement Sections
Location
Full Depth
Asphalt
(inches Asphalt)
Composite
Section
(inches Asphalt
/ inches
Aggregate
Base)
Rigid
Section
(inches
Concrete)
Private Parking
Lot 6 4.5 / 6 5
Private Drive
Lanes and
Heavy Truck
Traffic
6.5 5 / 6 6
1ST MAJOR AMENDMENT SUBMITTAL
MAJOR AMENDMENT
LOT 5
DH
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
DATE
DATE
DATE
DATE
DATE
DATE
CITY ENGINEER
WATER AND WASTEWATER UTILITY
STORMWATER UTILITY
PARKS AND RECREATION
TRAFFIC ENGINEER
LOT 5 Recommended Minimum Pavement Sections
Location
Full Depth
Asphalt
(inches Asphalt)
Composite
Section
(inches Asphalt
/ inches
Aggregate
Base)
Rigid
Section
(inches
Concrete)
Private Parking
Lot 6 4.5 / 6 5
Private Drive
Lanes and
Heavy Truck
Traffic
6.5 5 / 6 6
04/24/2015
1ST MAJOR AMENDMENT SUBMITTAL
MAJOR AMENDMENT
DH
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
DATE
DATE
DATE
DATE
DATE
DATE
CITY ENGINEER
WATER AND WASTEWATER UTILITY
STORMWATER UTILITY
PARKS AND RECREATION
TRAFFIC ENGINEER
C14.4 C14.3
C14.2
C14.1
PAVING PLAN
LEGEND
EXISTING PROPOSED
15.5 L.F.
OF 12" STORM
43.6 L.F.
OF 12" STORM
35.7 L.F.
OF 12" STORM
16.6 L.F.
OF 12" STORM
19.0 L.F.
OF 12" STORM
42.9 L.F. 4"
FIRE SERVICE
44.2 L.F. 4"
FIRE SERVICE
86.0 L.F.
OF 24" STORM
53.3 L.F.
OF 24" STORM
STORM MANHOLE
107.0 L.F.
OF 8" SANITARY
SEWER MAIN
120.0 L.F.
OF 8" SANITARY
SEWER MAIN 107.0 L.F.
OF 8" SANITARY
SEWER MAIN
59.9 L.F.
OF 8" SANITARY
SEWER MAIN
103.7 L.F.
OF 8" SANITARY
SEWER MAIN
134.0 L.F.
EXISITING 18" STORM
EXISITING 8"
WATER MAIN
CUT AND PATCH
STREET
CUT AND PATCH
STREET
CUT AND PATCH
STREET
CUT AND PATCH
STREET
101.0 L.F.
OF 18" STORM
CUT AND PATCH
STREET
TIE TO EXISTING WATERMAIN
EXISTING 10" WATERLINE
REVISIONS
NO.
REV.
DATE REVISIONS DESCRIPTION
project no.:
approved by:
checked by:
drawn by:
drawing no.:
QA/QC by:
date:
SHEET
TEL 970.461.7733 www.olssonassociates.com
5285 McWhinney Boulevard, Suite 160
Loveland, CO 80538
OLSSON ASSOCIATES ASSUMES
NO RESPONSIBILITY FOR
EXISTING UTILITY LOCATIONS
(HORIZONTAL OR VERTICAL). THE
EXISTING UTILITIES SHOWN ON
THIS DRAWING HAVE BEEN
PLOTTED FROM THE BEST
AVAILABLE INFORMATION. IT IS
HOWEVER THE RESPONSIBILITY
OF THE CONTRACTOR TO FIELD
VERIFY THE LOCATION OF ALL
UTILITIES PRIOR TO THE
COMMENCEMENT OF ANY
CONSTRUCTION ACTIVITIES.
NOTE
THIS DOCUMENT HAS BEEN
RELEASED BY OLSSON
ASSOCIATES ONLY FOR REVIEW
BY REGULATORY AGENCIES AND
OTHER PROFESSIONALS, AND IS
SUBJECT TO CHANGE. THIS
DOCUMENT IS NOT TO BE USED
FOR CONSTRUCTION.
CALL 811 SEVENTY-TWO HOURS
PRIOR TO DIGGING, GRADING OR
EXCAVATING FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES
UTILITY PLAN R
FORT COLLINS, COLORADO 2015
04/24/2015
015-0720
FOOTHILLS MALL REDEVELOPMENT
DH
150720_UTL03.dwg
DH
JG
C8.4
A
04/24/2015
1ST MAJOR AMENDMENT SUBMITTAL
MAJOR AMENDMENT
LOT 3 WEST
DH
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
DATE
DATE
DATE
DATE
DATE
DATE
CITY ENGINEER
WATER AND WASTEWATER UTILITY
STORMWATER UTILITY
PARKS AND RECREATION
TRAFFIC ENGINEER
SEE SHEET C8.3
MATCHLINE
LOT 3 WEST
230.2 L.F.
OF 8" SANITARY
SEWER MAIN
33.6 L.F.
OF 12" STORM
AREA INLET TYP. STORM MANHOLE
AREA INLET TYP.
EXISTING STORM MANHOLE
EXISTING SANITARY MANHOLE
93.7 L.F.
OF EXISITING 18" SANITARY
SEWER MAIN
64.7 L.F.
OF EXISITING 6" SANITARY
SEWER SERVICE
89.6 L.F.
EXISITING 60" STORM
185.3 L.F.
EXISITING 18" STORM
SANITARY MANHOLE
47.1 L.F.
OF 24" STORM
CUT AND PATCH
SIDEWALK
CUT AND PATCH
SIDEWALK
REVISIONS
NO.
REV.
DATE REVISIONS DESCRIPTION
project no.:
approved by:
checked by:
drawn by:
drawing no.:
QA/QC by:
date:
SHEET
TEL 970.461.7733 www.olssonassociates.com
5285 McWhinney Boulevard, Suite 160
Loveland, CO 80538
OLSSON ASSOCIATES ASSUMES
NO RESPONSIBILITY FOR
EXISTING UTILITY LOCATIONS
(HORIZONTAL OR VERTICAL). THE
EXISTING UTILITIES SHOWN ON
THIS DRAWING HAVE BEEN
PLOTTED FROM THE BEST
AVAILABLE INFORMATION. IT IS
HOWEVER THE RESPONSIBILITY
OF THE CONTRACTOR TO FIELD
VERIFY THE LOCATION OF ALL
UTILITIES PRIOR TO THE
COMMENCEMENT OF ANY
CONSTRUCTION ACTIVITIES.
NOTE
THIS DOCUMENT HAS BEEN
RELEASED BY OLSSON
ASSOCIATES ONLY FOR REVIEW
BY REGULATORY AGENCIES AND
OTHER PROFESSIONALS, AND IS
SUBJECT TO CHANGE. THIS
DOCUMENT IS NOT TO BE USED
FOR CONSTRUCTION.
CALL 811 SEVENTY-TWO HOURS
PRIOR TO DIGGING, GRADING OR
EXCAVATING FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES
UTILITY PLAN R
FORT COLLINS, COLORADO 2015
04/24/2015
015-0720
FOOTHILLS MALL REDEVELOPMENT
DH
150720_UTL03.dwg
DH
JG
C8.3
A
04/24/2015
1ST MAJOR AMENDMENT SUBMITTAL
MAJOR AMENDMENT
LOT 3 EAST
DH
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
DATE
DATE
DATE
DATE
DATE
DATE
CITY ENGINEER
WATER AND WASTEWATER UTILITY
STORMWATER UTILITY
PARKS AND RECREATION
TRAFFIC ENGINEER
MATCHLINE
SEE SHEET C8.4
LOT 3 EAST
1ST MAJOR AMENDMENT SUBMITTAL
MAJOR AMENDMENT
LOT 4
DH
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
DATE
DATE
DATE
DATE
DATE
DATE
CITY ENGINEER
WATER AND WASTEWATER UTILITY
STORMWATER UTILITY
PARKS AND RECREATION
TRAFFIC ENGINEER
LOT 4
1ST MAJOR AMENDMENT SUBMITTAL
MAJOR AMENDMENT
LOT 5
DH
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
DATE
DATE
DATE
DATE
DATE
DATE
CITY ENGINEER
WATER AND WASTEWATER UTILITY
STORMWATER UTILITY
PARKS AND RECREATION
TRAFFIC ENGINEER
LOT 5
04/24/2015
1ST MAJOR AMENDMENT SUBMITTAL
MAJOR AMENDMENT
DH
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
DATE
DATE
DATE
DATE
DATE
DATE
CITY ENGINEER
WATER AND WASTEWATER UTILITY
STORMWATER UTILITY
PARKS AND RECREATION
TRAFFIC ENGINEER
C8.4 C8.3
C8.2
C8.1
LEGEND
EXISTING PROPOSED
JG
C6.4
A
04/24/2015
1ST MAJOR AMENDMENT SUBMITTAL
MAJOR AMENDMENT
LOT 3 WEST
DH
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
DATE
DATE
DATE
DATE
DATE
DATE
CITY ENGINEER
WATER AND WASTEWATER UTILITY
STORMWATER UTILITY
PARKS AND RECREATION
TRAFFIC ENGINEER
SEE SHEET C6.3
MATCHLINE
LOT 3 WEST
DH
JG
C6.3
A
04/24/2015
1ST MAJOR AMENDMENT SUBMITTAL
MAJOR AMENDMENT
LOT 3 EAST
DH
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
DATE
DATE
DATE
DATE
DATE
DATE
CITY ENGINEER
WATER AND WASTEWATER UTILITY
STORMWATER UTILITY
PARKS AND RECREATION
TRAFFIC ENGINEER
MATCHLINE
SEE SHEET C6.4
LOT 3 EAST
1ST MAJOR AMENDMENT SUBMITTAL
MAJOR AMENDMENT
LOT 4
DH
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
DATE
DATE
DATE
DATE
DATE
DATE
CITY ENGINEER
WATER AND WASTEWATER UTILITY
STORMWATER UTILITY
PARKS AND RECREATION
TRAFFIC ENGINEER
LOT 4
1ST MAJOR AMENDMENT SUBMITTAL
MAJOR AMENDMENT
LOT 5
DH
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
DATE
DATE
DATE
DATE
DATE
DATE
CITY ENGINEER
WATER AND WASTEWATER UTILITY
STORMWATER UTILITY
PARKS AND RECREATION
TRAFFIC ENGINEER
LOT 5
04/24/2015
1ST MAJOR AMENDMENT SUBMITTAL
MAJOR AMENDMENT
DH
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
DATE
DATE
DATE
DATE
DATE
DATE
CITY ENGINEER
WATER AND WASTEWATER UTILITY
STORMWATER UTILITY
PARKS AND RECREATION
TRAFFIC ENGINEER
C6.4 C6.3
C6.2
C6.1
GRADING PLAN
LEGEND
EXISTING PROPOSED
1ST MAJOR AMENDMENT SUBMITTAL
MAJOR AMENDMENT
DH
PROJECT CONTROL:
BASIS OF BEARING:
THE BASIS OF BEARINGS IS THE WEST LINE OF LOT 1 OF THE REPLAT OF TRACTS F, G, AND
-$1'9$&$7('6(59,&(52$'6287+02259,//$*(),)7+),/,1*%(,1*6
:
MONUMENTED ON THE NORTH BY A NO. 5 REBAR WITH YELLOW PLASTIC CAP STAMPED PLS
38098 AND ON THE SOUTH BY A NO. 5 REBAR WITH BLUE PLASTIC CAP STAMPED LS14823.
LOT 3, 4 & 5 OF FOOTHILLS MALL REDEVELOPMENT
SUBDIVISION LOCATED IN THE SOUTHWEST QUARTER OF
SECTION 25, TOWNSHIP 5 NORTH, RANGE 69 WEST OF
THE 6TH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS,
COUNTY OF LARIMER, STATE OF COLORADO
MAJOR AMENDMENT
FOOTHILLS MALL REDEVELOPMENT,
A PORTION OF PLANNING AREA 3
UTILITY PLANS
ARCHITECT
OLSSON ASSOCIATES
5285 McWHINNEY BOULEVARD, SUITE 160
LOVELAND, CO 80538
PHONE: (970) 461-7733
ENGINEER
OWNER LANDSCAPE
PROJECT TEAM CONTACTS
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
DATE
DATE
DATE
DATE
DATE
DATE
CITY ENGINEER
WATER AND WASTEWATER UTILITY
STORMWATER UTILITY
PARKS AND RECREATION
TRAFFIC ENGINEER
VICINITY MAP
SCALE=1"=1000'
PROPOSED SITE
BENCHMARKS (CITY OF FORT COLLINS NETWORK)
BENCHMARK: D-322
MONUMENT TYPE: NGS BENCHMARK DISK STAMPED "D 322 RESET 1971"
ELEVATION: 5031.28 FEET
DATUM: NGVD 1929 UNADJUSTED
DESCRIPTION: 5.4 KM (3.35 MI) SOUTH ALONG U.S. HIGHWAY 287 FROM ITS JUNCTION
WITH STATE HIGHWAY 14 IN FORT COLLINS, IN THE NORTH END OF THE EAST CONCRETE
HEADWALL OF AN 8-BY-24 FOOT BOX CULVERT, 6.1 METERS (20.0 FT) EAST OF THE
CENTERLINE OF THE NORTH BOUND LANES OF THE HIGHWAY, AND 1.7 METERS (5.6 FT)
SOUTH OF THE NORTH END OF THE HEADWALL. THE MARK IS ABOVE LEVEL WITH THE
HIGHWAY.
BENCHMARK: E-322
MONUMENT TYPE: NGS BENCHMARK DISK STAMPED "E-322 RESET 1971"
ELEVATION: 5031.21 FEET
DATUM: NGVD 1929 UNADJUSTED
DESCRIPTION: 5.9 KM (3.65 MI) SOUTH ALONG U.S. HIGHWAY 287 FROM ITS JUNCTION
WITH STATE HIGHWAY 14 IN FORT COLLINS, IN THE SOUTH END OF THE WEST CONCRETE
HEADWALL OF AN 8-BY-24 FOOT BOX CULVERT, 51.0 METERS (167.3 FT) SOUTH OF THE
CENTERLINE OF THE EAST BOUND LANES OF HORSETOOTH ROAD, AND 5.7 METERS (18.7
FT) WEST OF THE CENTERLINE OF THE SOUTH BOUND LANES OF THE HIGHWAY. THE
MARK IS ABOVE LEVEL WITH THE HIGHWAY.
JG JOHNSON ARCHITECTS
1600 WYNKOOP ST. SUITE 100
DENVER, CO 80202
PHONE: (303) 892-7062
TB GROUP
444 MOUNTAIN AVENUE
BERTHOUD, CO 80513
PHONE: (970) 532-5891
DEVELOPER
MCWHINNEY REAL ESTATE SERVICES
2725 ROCKY MOUNTAIN AVENUE
SUITE #200
LOVELAND, CO 80538
PHONE: (970) 962-9990
WALTON FOOTHILLS HOLDINGS VI, LLC
5750 DTC PARKWAY
SUITE 210
GREENWOOD VILLAGE, CO 80111
PHONE: (303) 771-4004
SHEET LIST TABLE
Sheet Number Sheet Title
C1.0 COVER SHEET
C6.0 OVERALL GRADING PLAN
C6.1 GRADING PLAN
C6.2 GRADING PLAN
C6.3 GRADING PLAN
C6.4 GRADING PLAN
C8.0 OVERALL UTILITY PLAN
C8.1 UTILITY PLAN
C8.2 UTILITY PLAN
C8.3 UTILITY PLAN
C8.4 UTILITY PLAN
C14.0 OVERALL PAVING PLAN
C14.1 PAVING PLAN
C14.2 PAVING PLAN
C14.3 PAVING PLAN
C14.4 PAVING PLAN
REVISIONS
A
04/24/2015
LEGEND
EXISTING PROPOSED EXISTING PROPOSED