Loading...
HomeMy WebLinkAboutREGISTRY RIDGE SEVENTH FILING, REPLAT OF FILINGS TWO & FOUR - FDP - FDP150015 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSUTILITY PLANS FOR REGISTRY RIDGE SEVENTH FILING BEING A REPLAT OF TRACT B, AND A PORTION OF TRACT A, OF THE REGISTRY RIDGE P.U.D., SECOND FILING AND ALL OF REGISTRY RIDGE FOURTH FILING, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO MARCH 2015 THESE PLANS HAVE BEEN REVIEWED BY THE LOCAL ENTITY FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BY THE REVIEWING DEPARTMENT, THE LOCAL ENTITY ENGINEER, OR THE LOCAL ENTITY FOR ACCURACY AND CORRECTNESS OF THE CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT QUANTITIES OF ITEMS ON THE PLANS ARE THE FINAL QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE LOCAL ENTITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE CONSTRUCTION PHASE. I HEREBY AFFIRM THAT THESE FINAL CONSTRUCTION PLANS WERE PREPARED UNDER MY DIRECT SUPERVISION, IN ACCORDANCE WITH ALL APPLICABLE CITY OF FORT COLLINS AND STATE OF COLORADO STANDARDS AND STATUTES, RESPECTIVELY; AND THAT I AM FULLY RESPONSIBLE FOR THE ACCURACY OF ALL DESIGN, REVISIONS, AND RECORD CONDITIONS THAT I HAVE NOTED ON THESE PLANS. KEVIN BRAZELTON, PE #38837 DATE SCALE: 1"=400' CERTIFICATION STATEMENT DISCLAIMER STATEMENT VICINITY MAP OWNER / DEVELOPER BQ, LLC 10221 PRESTWICK TRAIL LONE TREE, CO 80124 CONTACT: 303-587-1966 PHONE: BOB QUINETTE CIVIL ENGINEER UNITED CIVIL DESIGN GROUP, LLC 1501 ACADEMY CT., STE 203 FORT COLLINS, CO 80524 PHONE: 970-530-4044 CONTACT: KEVIN BRAZELTON SURVEYOR KING SURVEYORS, INC. 650 GARDEN DRIVE WINDSOR, CO 80550 PHONE: 970-686-5011 CONTACT: LARRY PEPEK PROJECT TEAM PROJECT COORDINATES VERTICAL DATUM: PROJECT VERTICAL DATUM IS NAVD 88. BENCHMARK #1: CITY OF FORT COLLINS 10-13 SOUTHEAST CORNER OF SHIELDS ST. AND TRILBY ROAD. , ON A CONCRETE TRAFFIC SIGNAL BASE. ELEVATION=5066.93 (NAVD 88 DATUM) BENCHMARK #2: CITY OF FORT COLLINS 45-01 SOUTH SIDE OF TRILBY ROAD, APPROXIMATELY 0.5 MILES EAST OF TAFT HILL ROAD, ON AN 8'x8' CONCRETE PAD FOR A WATER VALVE AND A LARGE BLACK PIPE. ELEVATION=5069.38 (NAVD 88 DATUM) BASIS OF BEARINGS: PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING TRAFFIC SIGNING AND PAVEMENT MARKING CONSTRUCTION NOTES 1. All signage and marking is subject to the General Notes on the Cover Sheet of these plans, as well as the traffic signing and marking construction notes listed here. 2. All symbols, including arrows, ONLY's, crosswalks, stop bars, etc. shall be preformed thermoplastic. 3. All signage shall be per local entity standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Preformed thermoplastic applications shall be as specified in these plans and/or these standards. 8. Epoxy applications shall be applied as specified in CDOT standard specifications for road and bridge construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer . All discrepancies identified during the field inspection must be corrected before the two year warranty period will begin. 12. The developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period, the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S standards. All signage and striping shall fall under the requirements of the two year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. STANDARD EROSION AND SEDIMENT CONTROL CONSTRUCTION PLAN NOTES 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize windblown sediment. The developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (striping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPS are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the city/county. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: A. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. B. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. C. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the developer shall be responsible for the cleanup and removal of all sediment and debris from all drainage SHEET 3 SHEET 3 SHEET 5 SHEET 4 SHEET INDEX Being a Replat Of Tract B And A Portion of Tract A, Of The Registry Ridge P.U. D., Second Filing, And Of All Of Registry Ridge Fourth Filing City Of Fort Collins, County Of Larimer, State Of Colorado (For Recording Purposes: Part of The Northeast Quarter of Section 15, Township 6 North, Range 69 West of The 6th P.M.) VICINITY MAP ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ´ ³ ´ ³ ´ KING SURVEYORS 650 E. Garden Drive | Windsor, Colorado 80550 phone: (970) 686-5011 | fax: (970) 686-5821 1 LAND USE TABLE LOTS (74) 7.669 ACRES 65% OUTLOTS (3) 2.323 ACRES 20% TRACTS (4) 0.844 ACRES 7% RIGHT OF WAY 0.994 ACRES 8% TOTAL 11.831 ACRES 100% CURVE DATA NOTE: Was unable to reconcile all the curve data components on curves C5, C6, C7 & C8 to match perfectly with the previous plat data. Elected to hold the Delta Angle component on those 4 curves and allow the Chord Bearing component to be the variable data. N:\2014615\DWG\2014615SUB.dwg, 3/17/2015 8:23:06 AM 7 TRACT A TRACT B TRACT C OUTLOT A OUTLOT B OUTLOT C 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 6 6 6 6 6 6 TRACT A 5,307 SQ.FT. 0.122 ACRES OUTLOT A 17,132 SQ.FT. 0.393 ACRES LOT 1 3,152 SQ.FT. LOT 2 3,320 SQ.FT. LOT 3 3,620 SQ.FT. LOT 4 3,767 SQ.FT. LOT 5 3,750 SQ.FT. LOT 6 3,750 SQ.FT. LOT 1 5,865 SQ.FT. LOT 2 4,335 SQ.FT. LOT 3 3,750 SQ.FT. LOT 4 3,750 SQ.FT. LOT 1 3,506 SQ.FT. BLOCK 1 BLOCK 2 OUTLOT A 17,132 SQ.FT. 0.393 ACRES LEGEND OUTLOT C 67,261 SQ.FT. 1.544 ACRES LOT 10 4,790 SQ.FT. LOT 4 6,927 SQ.FT. LOT 5 7,358 SQ.FT. LOT 6 7,414 SQ.FT. LOT 7 7,138 SQ.FT. LOT 8 7,113 SQ.FT. LOT 9 5,744 SQ.FT. LOT 10 6,291 SQ.FT. BLOCK 8 SHEET 3 SHEET 3 SHEET 5 SHEET 4 SHEET INDEX KING SURVEYORS TRACT B 13,744 SQ.FT. 0.316 ACRES OUTLOT B 16,800 SQ.FT. 0.386 ACRES 4,335 SQ.FT. LOT 1 3,506 SQ.FT. LOT 2 3,500 SQ.FT. LOT 6 3,188 SQ.FT. LOT 5 3,187 SQ.FT. LOT 4 3,188 SQ.FT. LOT 3 4,037 SQ.FT. LOT 14 3,341 SQ.FT. LOT 13 3,429 SQ.FT. LOT 1 3,278 SQ.FT. LOT 2 3,200 SQ.FT. LOT 3 3,827 SQ.FT. LOT 4 3,787 SQ.FT. LOT 5 3,187 SQ.FT. LOT 6 3,187 SQ.FT. LOT 7 3,187 SQ.FT. LOT 8 3,187 SQ.FT. LOT 9 3,187 SQ.FT. LOT 10 3,187 SQ.FT. LOT 11 3,787 SQ.FT. LOT 12 4,036 SQ.FT. LOT 10 6,291 SQ.FT. BLOCK 3 BLOCK 4 BLOCK 4 BLOCK 4 BLOCK 5 BLOCK 9 BLOCK 8 OUTLOT A 17,132 SQ.FT. 0.393 ACRES BLOCK 9 TRACT B 13,744 SQ.FT. 0.316 ACRES TRACT C 10,023 SQ.FT. 0.230 ACRES TRACT D 7,723 SQ.FT. 0.177 ACRES LOT 1 3,921 SQ.FT. LOT 2 3,865 SQ.FT. LOT 3 4,037 SQ.FT. LOT 4 4,117 SQ.FT. LOT 5 4,125 SQ.FT. LOT 6 4,125 SQ.FT. LOT 7 4,125 SQ.FT. LOT 8 4,432 SQ.FT. LOT 1 4,577 SQ.FT. LOT 2 4,125 SQ.FT. LOT 3 4,125 SQ.FT. LOT 4 4,125 SQ.FT. LOT 5 4,125 SQ.FT. LOT 6 4,125 SQ.FT. LOT 7 4,125 SQ.FT. LOT 8 4,125 SQ.FT. LOT 9 4,125 SQ.FT. LOT 10 4,790 SQ.FT. LOT 1 5,244 SQ.FT. LOT 2 3,956 SQ.FT. LOT 3 4,163 SQ.FT. LOT 4 4,172 SQ.FT. LOT 5 4,172 SQ.FT. LOT 6 4,163 SQ.FT. LOT 7 3,954 SQ.FT. LOT 8 5,219 SQ.FT. LOT 1 5,344 SQ.FT. LOT 2 PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING EXISTING CONDITIONS & REMOVALS - NORTH C100 N/A 40' 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. THE CONTRACTOR SHALL PROTECT ALL EXISTING FEATURES THAT ARE NOT TO BE REMOVED ADJACENT TO THE CONSTRUCTION AREA INCLUDING, BUT NOT LIMITED TO, PAVEMENT, PRIVATE FENCES, ABOVE GROUND OR UNDERGROUND UTILITIES, STRUCTURES, AND UNDERGROUND FOUNDATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE THAT SHOULD OCCUR TO ANY ON-SITE, OFF-SITE, PUBLIC OR PRIVATE FACILITY OR FEATURE AS A RESULT OF THE CONSTRUCTION PROCESS FOR THIS PROJECT. 3. LIMITS OF STREET CUT AS REQUIRED FOR UTILITY CONSTRUCTION ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 4. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES. 5. EXISTING SEWER SERVICES AS SHOWN ON THIS DRAWING TO BE REMOVED SHALL BE REMOVED TO THE MAIN PER SOUTH FORT COLLINS SANITATION DISTRICT STANDARDS (LATEST EDITION.) PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING EXISTING CONDITIONS & REMOVALS - SOUTH C101 N/A 40' 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. THE CONTRACTOR SHALL PROTECT ALL EXISTING FEATURES THAT ARE NOT TO BE REMOVED ADJACENT TO THE CONSTRUCTION AREA INCLUDING, BUT NOT LIMITED TO, PAVEMENT, PRIVATE FENCES, ABOVE GROUND OR UNDERGROUND UTILITIES, STRUCTURES, AND UNDERGROUND FOUNDATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE THAT SHOULD OCCUR TO ANY ON-SITE, OFF-SITE, PUBLIC OR PRIVATE FACILITY OR FEATURE AS A RESULT OF THE CONSTRUCTION PROCESS FOR THIS PROJECT. 3. LIMITS OF STREET CUT AS REQUIRED FOR UTILITY CONSTRUCTION ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 4. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES. 5. EXISTING SEWER SERVICES AS SHOWN ON THIS DRAWING TO BE REMOVED SHALL BE REMOVED TO THE MAIN PER SOUTH FORT COLLINS SANITATION DISTRICT STANDARDS (LATEST EDITION.) PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING HORIZONTAL CONTROL AND PAVEMENT PLAN NORTH C200 N/A CHECKED BY: 40' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 40' 80' SCALE: 1" = 40' 20' 1. ALL DIMENSIONS AND LINE AND CURVE INFORMATION ARE MEASURED TO CURB FLOW LINE OR EDGE OF PAVEMENT UNLESS OTHERWISE NOTED. 2. CONTRACTOR SHALL REFER TO AND COORDINATE WITH THE APPROVED LANDSCAPE DRAWINGS FOR ALL LANDSCAPE AND SITE FEATURES SUCH AS LANDSCAPE WALLS, SEEDING/SOD, LANDSCAPE ROCK AND MULCH, ETC. 3. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 4. CONCRETE SIDEWALKS ADJACENT TO PUBLIC RIGHT-OF-WAY SHALL BE 6-INCH MINIMUM THICKNESS. 5. ALL HANDICAP RAMPS (PRIVATE AND PUBLIC) SHALL BE INSTALLED WITH TRUNCATED DOME WARNING DETECTION SYSTEMS PER LARIMER COUNTY URBAN AREA STREET STANDARD DETAILS. 6. LIMITS OF STREET CUT AS REQUIRED FOR UTILITY CONSTRUCTION ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 7. 2-INCH MILL AND OVERLAY OF ENTERPRISE DRIVE PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING HORIZONTAL CONTROL AND PAVEMENT PLAN SOUTH C201 N/A CHECKED BY: 40' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 40' 80' SCALE: 1" = 40' 20' 1. ALL DIMENSIONS AND LINE AND CURVE INFORMATION ARE MEASURED TO CURB FLOW LINE OR EDGE OF PAVEMENT UNLESS OTHERWISE NOTED. 2. CONTRACTOR SHALL REFER TO AND COORDINATE WITH THE APPROVED LANDSCAPE DRAWINGS FOR ALL LANDSCAPE AND SITE FEATURES SUCH AS LANDSCAPE WALLS, SEEDING/SOD, LANDSCAPE ROCK AND MULCH, ETC. 3. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 4. CONCRETE SIDEWALKS ADJACENT TO PUBLIC RIGHT-OF-WAY SHALL BE 6-INCH MINIMUM THICKNESS. 5. ALL HANDICAP RAMPS (PRIVATE AND PUBLIC) SHALL BE INSTALLED WITH TRUNCATED DOME WARNING DETECTION SYSTEMS PER LARIMER COUNTY URBAN AREA STREET STANDARD DETAILS. 6. LIMITS OF STREET CUT AS REQUIRED FOR UTILITY CONSTRUCTION ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 7. 2-INCH MILL AND OVERLAY OF ENTERPRISE DRIVE PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING UTILITY PLAN NORTH C300 N/A CHECKED BY: 40' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 40' 80' SCALE: 1" = 40' 20' LEGEND SANITARY SEWER M.H. FIRE HYDRANT STORM DRAIN PIPE SANITARY SEWER STORM DRAIN INLET WATER LINE BENDS THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE WATER SERVICE SANITARY SERVICE STORM END SECTION MAPPING EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER M.H. SANITARY SEWER M.H. GAS LINE ELECTRIC LINE STREET LIGHT S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING UTILITY PLAN SOUTH C301 N/A CHECKED BY: 40' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 40' 80' SCALE: 1" = 40' 20' LEGEND SANITARY SEWER M.H. FIRE HYDRANT STORM DRAIN PIPE SANITARY SEWER STORM DRAIN INLET WATER LINE BENDS THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE WATER SERVICE SANITARY SERVICE STORM END SECTION MAPPING EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER M.H. SANITARY SEWER M.H. GAS LINE ELECTRIC LINE STREET LIGHT S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING 0 30' 60' SCALE: 1" = 30' 15' SANITARY SEWER PLAN & PROFILE LINE A & LINE B C400 3' 30' SANITARY SEWER LINE A 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 3. THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING ELEVATIONS OF ALL EXISTING SEWER MAINS, WATER MAINS, CURBS, GUTTERS AND OTHER UTILITIES AT THE POINTS OF CONNECTION SHOWN ON THE PLANS, AND AT ANY UTILITY CROSSINGS PRIOR TO INSTALLING ANY OF THE NEW IMPROVEMENTS. IF A CONFLICT EXISTS AND/OR A DESIGN MODIFICATION IS REQUIRED, THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE IN PAVED AREAS. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 5. SANITARY SEWER MAINS AND SERVICES SHALL BE SDR-35 PVC. 6. SANITARY SEWER SERVICES ARE 4" IN SIZE UNLESS NOTED OTHERWISE. 7. SEE HORIZONTAL CONTROL PLAN FOR REFERENCE VALUES FOR COORDINATES SHOWN. 8. REFER TO SHEETS C300 - C301 FOR SANITARY SERVICE LOCATIONS. LOT LINES EASEMENT LINES RIGHT-OF-WAY LEGEND NOTES SANITARY SEWER M.H. FIRE HYDRANT STORM DRAIN PIPE SANITARY SEWER STORM DRAIN M.H. WATER LINE BENDS THRUST BLOCK GATE VALVE PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING 0 30' 60' SCALE: 1" = 30' 15' SANITARY SEWER PLAN & PROFILE LINE C C401 3' 30' SANITARY SEWER LINE C 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 3. THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING ELEVATIONS OF ALL EXISTING SEWER MAINS, WATER MAINS, CURBS, GUTTERS AND OTHER UTILITIES AT THE POINTS OF CONNECTION SHOWN ON THE PLANS, AND AT ANY UTILITY CROSSINGS PRIOR TO INSTALLING ANY OF THE NEW IMPROVEMENTS. IF A CONFLICT EXISTS AND/OR A DESIGN MODIFICATION IS REQUIRED, THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE IN PAVED AREAS. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 5. SANITARY SEWER MAINS AND SERVICES SHALL BE SDR-35 PVC. 6. SANITARY SEWER SERVICES ARE 4" IN SIZE UNLESS NOTED OTHERWISE. 7. SEE HORIZONTAL CONTROL PLAN FOR REFERENCE VALUES FOR COORDINATES SHOWN. 8. REFER TO SHEETS C300 - C301 FOR SANITARY SERVICE LOCATIONS. LOT LINES EASEMENT LINES RIGHT-OF-WAY LEGEND NOTES SANITARY SEWER M.H. FIRE HYDRANT STORM DRAIN PIPE SANITARY SEWER STORM DRAIN M.H. WATER LINE BENDS THRUST BLOCK GATE VALVE PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING 0 30' 60' SCALE: 1" = 30' 15' SANITARY SEWER PLAN & PROFILE LINE C6 C402 3' 30' SANITARY SEWER LINE C6 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 3. THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING ELEVATIONS OF ALL EXISTING SEWER MAINS, WATER MAINS, CURBS, GUTTERS AND OTHER UTILITIES AT THE POINTS OF CONNECTION SHOWN ON THE PLANS, AND AT ANY UTILITY CROSSINGS PRIOR TO INSTALLING ANY OF THE NEW IMPROVEMENTS. IF A CONFLICT EXISTS AND/OR A DESIGN MODIFICATION IS REQUIRED, THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE IN PAVED AREAS. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 5. SANITARY SEWER MAINS AND SERVICES SHALL BE SDR-35 PVC. 6. SANITARY SEWER SERVICES ARE 4" IN SIZE UNLESS NOTED OTHERWISE. 7. SEE HORIZONTAL CONTROL PLAN FOR REFERENCE VALUES FOR COORDINATES SHOWN. 8. REFER TO SHEETS C300 - C301 FOR SANITARY SERVICE LOCATIONS. LOT LINES EASEMENT LINES RIGHT-OF-WAY LEGEND NOTES SANITARY SEWER M.H. FIRE HYDRANT STORM DRAIN PIPE SANITARY SEWER STORM DRAIN M.H. WATER LINE BENDS THRUST BLOCK GATE VALVE PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING STORM SEWER PLAN & PROFILE LINES 1, 2 & 3 C500 3' 30' 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. THE PROPOSED CONSTRUCTION WILL BE IN CLOSE PROXIMITY TO SEVERAL UNDERGROUND UTILITIES. THE CONTRACTOR SHALL COORDINATE WITH ALL UTILITY PROVIDERS PRIOR TO AND DURING CONSTRUCTION TO MINIMIZE SERVICE INTERRUPTIONS TO SURROUNDING BUILDINGS OR PROPERTIES. 3. ALL STORM SEWER CONSTRUCTION SHALL SHALL BE PER THE CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS FOR PUBLIC IMPROVEMENTS, LATEST EDITION. 4. ALL PIPE LENGTHS ARE FROM CENTER TO CENTER OF ADJACENT STRUCTURES. DESIGN LENGTH OF THE PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 5. STORM SEWER MAINS SHOWN ON THESE DRAWINGS AS REINFORCED CONCRETE PIPE (RCP) SHALL BE CLASS III UNLESS OTHERWISE NOTED. STORM SEWER MAINS SHOWN ON THESE DRAWINGS AS HIGH DENSITY POLYETHYLENE (HDPE) SHALL BE WATERTIGHT ADS-N12 OR APPROVED EQUAL. 6. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES UNLESS OTHERWISE DIRECTED IN THE DRAWINGS. 7. SEE HORIZONTAL CONTROL PLAN FOR REFERENCE VALUES FOR COORDINATES SHOWN. LOT LINES / R.O.W. EASEMENT LINES CENTERLINE LEGEND NOTES SANITARY SEWER M.H. FIRE HYDRANT STORM DRAIN PIPE SANITARY SEWER STORM DRAIN INLET STORM DRAIN M.H. WATER LINE BENDS PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING STORM SEWER PLAN & PROFILE LINES 4, 5 & 6 C501 3' 30' 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. THE PROPOSED CONSTRUCTION WILL BE IN CLOSE PROXIMITY TO SEVERAL UNDERGROUND UTILITIES. THE CONTRACTOR SHALL COORDINATE WITH ALL UTILITY PROVIDERS PRIOR TO AND DURING CONSTRUCTION TO MINIMIZE SERVICE INTERRUPTIONS TO SURROUNDING BUILDINGS OR PROPERTIES. 3. ALL STORM SEWER CONSTRUCTION SHALL SHALL BE PER THE CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS FOR PUBLIC IMPROVEMENTS, LATEST EDITION. 4. ALL PIPE LENGTHS ARE FROM CENTER TO CENTER OF ADJACENT STRUCTURES. DESIGN LENGTH OF THE PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 5. STORM SEWER MAINS SHOWN ON THESE DRAWINGS AS REINFORCED CONCRETE PIPE (RCP) SHALL BE CLASS III UNLESS OTHERWISE NOTED. STORM SEWER MAINS SHOWN ON THESE DRAWINGS AS HIGH DENSITY POLYETHYLENE (HDPE) SHALL BE WATERTIGHT ADS-N12 OR APPROVED EQUAL. 6. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES UNLESS OTHERWISE DIRECTED IN THE DRAWINGS. 7. SEE HORIZONTAL CONTROL PLAN FOR REFERENCE VALUES FOR COORDINATES SHOWN. LOT LINES / R.O.W. EASEMENT LINES CENTERLINE LEGEND NOTES SANITARY SEWER M.H. FIRE HYDRANT STORM DRAIN PIPE SANITARY SEWER STORM DRAIN INLET STORM DRAIN M.H. WATER LINE BENDS PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING OVERLOT GRADING & EROSION CONTROL PLAN NORTH C600 N/A CHECKED BY: 40' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 40' 80' SCALE: 1" = 40' 20' LEGEND 5124 5124 PROPOSED 1' CONTOUR EXISTING 1' CONTOUR STORM SEWER STORM INLET NOTES 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. VEGETATIVE SWALES, PERMEABLE PAVERS AND THE POROUS LANDSCAPE DETENTION SHALL BE MAINTAINED BY THE PROPERTY OWNER OR HOA AND FOLLOW APPLICABLE STANDARD OPERATING PROCEDURES AS SHOWN IN DRAINAGE REPORT FOR REGISTRY RIDGE SEVENTH FILING. 3. SPOT ELEVATIONS SHOWN ARE TO FLOWLINE, EDGE OF WALK, OR LOT CORNER UNLESS OTHERWISE NOTED. 4. ALL DISTURBED AREAS NOT PAVED SHALL BE REVEGETATED PER THE LANDSCAPE PLANS. 5. REFER TO SHEETS C602-C603 FOR DETAILED GRADING PLANS. 6. REFER TO SHEETS C702-C703 FOR INTERSECTION GRADING PLANS. 7. TEMPORARY EROSION CONTROL BLANKETS (ECB) SHALL BE NORTH AMERICAN GREEN ERONET S75 OR APPROVED EQUAL. SILT FENCE VEHICLE TRACKING CONTROL PAD RIPRAP WATTLE DIKE PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING OVERLOT GRADING & EROSION CONTROL PLAN SOUTH C601 N/A CHECKED BY: 40' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: LEGEND 5124 5124 PROPOSED 1' CONTOUR EXISTING 1' CONTOUR STORM SEWER STORM INLET NOTES 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. VEGETATIVE SWALES, PERMEABLE PAVERS AND THE POROUS LANDSCAPE DETENTION SHALL BE MAINTAINED BY THE PROPERTY OWNER OR HOA AND FOLLOW APPLICABLE STANDARD OPERATING PROCEDURES AS SHOWN IN DRAINAGE REPORT FOR REGISTRY RIDGE SEVENTH FILING. 3. SPOT ELEVATIONS SHOWN ARE TO FLOWLINE, EDGE OF WALK, OR LOT CORNER UNLESS OTHERWISE NOTED. 4. ALL DISTURBED AREAS NOT PAVED SHALL BE REVEGETATED PER THE LANDSCAPE PLANS. 5. REFER TO SHEETS C602-C603 FOR DETAILED GRADING PLANS. 6. REFER TO SHEETS C702-C703 FOR INTERSECTION GRADING PLANS. 7. TEMPORARY EROSION CONTROL BLANKETS (ECB) SHALL BE NORTH AMERICAN GREEN ERONET S75 OR APPROVED EQUAL. SILT FENCE VEHICLE TRACKING CONTROL PAD RIPRAP WATTLE DIKE CONCRETE WASHOUT AREA - FINAL LOCATION PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING DETAILED GRADING PLAN C602 N/A CHECKED BY: 40' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 40' 80' SCALE: 1" = 40' 20' S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP LOT LINES EASEMENT LINES CENTERLINE PROPOSED ROAD EXISTING ROAD LEGEND 5124 5124 PROPOSED 1' CONTOUR EXISTING 1' CONTOUR STORM SEWER STORM INLET A FHA 'A' LOT B FHA 'B' LOT G FHA GARDEN LOT T TRANSITION LOT GRADE BREAK FINISHED GRADE TF TOP OF FOUNDATION FG RIGHT OF WAY NOTES PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING DETAILED GRADING PLAN C603 N/A CHECKED BY: 40' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 40' 80' SCALE: 1" = 40' 20' LOT LINES EASEMENT LINES CENTERLINE PROPOSED ROAD EXISTING ROAD LEGEND 5124 5124 PROPOSED 1' CONTOUR EXISTING 1' CONTOUR STORM SEWER STORM INLET A FHA 'A' LOT B FHA 'B' LOT G FHA GARDEN LOT T TRANSITION LOT GRADE BREAK FINISHED GRADE TF TOP OF FOUNDATION FG RIGHT OF WAY S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP NOTES PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING LEGEND NOTES 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2. THE PROPOSED CONSTRUCTION WILL BE IN CLOSE PROXIMITY TO SEVERAL UNDERGROUND UTILITIES. THE CONTRACTOR SHALL COORDINATE WITH ALL UTILITY PROVIDERS PRIOR TO AND DURING CONSTRUCTION TO MINIMIZE SERVICE INTERRUPTIONS TO SURROUNDING BUILDINGS OR PROPERTIES. 3. PAVEMENT SECTION INFORMATION FOR ALL PAVEMENT WITHIN PUBLIC RIGHT-OF-WAY SHALL BE APPROVED BY THE CITY OF FORT COLLINS WITH A FINAL PAVEMENT DESIGN REPORT DURING CONSTRUCTION PER LARIMER COUNTY URBAN AREA STREET STANDARDS (LCUASS) SECTION 10.2. 4. SEE SHEET C701 FOR CENTERLINE AND FLOWLINE PROFILE INFORMATION. 5. SEE SHEETS C702-C703 FOR INTERSECTION DETAILS. 6. SEE SHEET C704 FOR STRIPING AND SIGNING INFORMATION. 7. SEE HORIZONTAL CONTROL PLAN FOR REFERENCE VALUES FOR COORDINATES SHOWN. LOT LINES EASEMENT LINES PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING LEGEND NOTES 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2. THE PROPOSED CONSTRUCTION WILL BE IN CLOSE PROXIMITY TO SEVERAL UNDERGROUND UTILITIES. THE CONTRACTOR SHALL COORDINATE WITH ALL UTILITY PROVIDERS PRIOR TO AND DURING CONSTRUCTION TO MINIMIZE SERVICE INTERRUPTIONS TO SURROUNDING BUILDINGS OR PROPERTIES. 3. PAVEMENT SECTION INFORMATION FOR ALL PAVEMENT WITHIN PUBLIC RIGHT-OF-WAY SHALL BE APPROVED BY THE CITY OF FORT COLLINS WITH A FINAL PAVEMENT DESIGN REPORT DURING CONSTRUCTION PER LARIMER COUNTY URBAN AREA STREET STANDARDS (LCUASS) SECTION 10.2. 4. SEE SHEET C701 FOR CENTERLINE AND FLOWLINE PROFILE INFORMATION. 5. SEE SHEETS C702-C703 FOR INTERSECTION DETAILS. 6. SEE SHEET C704 FOR STRIPING AND SIGNING INFORMATION. 7. SEE HORIZONTAL CONTROL PLAN FOR REFERENCE VALUES FOR COORDINATES SHOWN. LOT LINES EASEMENT LINES PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING LEGEND NOTES 1. SPOT ELEVATIONS SHOWN ARE TO FLOWLINE OR EDGE OF WALK UNLESS OTHERWISE NOTED. LOT LINES / R.O.W. EASEMENT LINES CENTERLINE PROPOSED CURB & GUTTER S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP 0 20' 40' SCALE: 1" = 20' 10' INTERSECTION DETAILS C702 N/A CHECKED BY: 20' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: NIMITZ DRIVE / BON HOMME RICHARD DRIVE INTERSECTION DETAIL NOTE: ALL STATIONS AND OFFSETS ARE BASED ON THE NIMITZ DRIVE ALIGNMENT UNLESS OTHERWISE NOTED NIMITZ DRIVE / CABOT DRIVE (PRIVATE DRIVE) INTERSECTION DETAIL NOTE: ALL STATIONS AND OFFSETS ARE BASED ON THE NIMITZ DRIVE ALIGNMENT UNLESS OTHERWISE NOTED ENTERPRISE DRIVE / BON HOMME RICHARD DRIVE INTERSECTION DETAIL NOTE: ALL STATIONS AND OFFSETS ARE BASED ON THE HORSE STAGE COURT ALIGNMENT UNLESS OTHERWISE NOTED ENTERPRISE DRIVE / CABOT DRIVE (PRIVATE DRIVE) PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING 0 20' 40' SCALE: 1" = 20' 10' INTERSECTION DETAILS C703 N/A CHECKED BY: 20' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: CABOT COURT (PRIVATE DRIVE) INTERSECTION DETAIL NOTE: ALL STATIONS AND OFFSETS ARE BASED ON THE CABOT COURT ALIGNMENT UNLESS OTHERWISE NOTED KITTY HAWK COURT (PRIVATE DRIVE) INTERSECTION DETAIL NOTE: ALL STATIONS AND OFFSETS ARE BASED ON THE KITTY HAWK COURT ALIGNMENT UNLESS OTHERWISE NOTED SAIPAN COURT (PRIVATE DRIVE) / ENTERPRISE DRIVE INTERSECTION DETAIL NOTE: ALL STATIONS AND OFFSETS ARE BASED ON THE SAIPAN COURT ALIGNMENT UNLESS OTHERWISE NOTED LEGEND NOTES 1. SPOT ELEVATIONS SHOWN ARE TO FLOWLINE OR EDGE OF WALK UNLESS OTHERWISE NOTED. LOT LINES / R.O.W. EASEMENT LINES CENTERLINE PROPOSED CURB & GUTTER S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP BLOCK 3 PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING SIGNING AND STRIPING PLAN C704 N/A N/A 1. ALL SIGNAGE SHALL BE PER CITY OF FORT COLLINS STANDARDS AND THESE PLANS OR AS OTHERWISE SPECIFIED IN MUTCD. 2. EPOXY APPLICATIONS SHALL BE APPLIED AS SPECIFIED IN CDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. 3. ALL SURFACES SHALL BE THOROUGHLY CLEANED PRIOR TO INSTALLATION OF STRIPING OR MARKINGS. 4. THE DEVELOPER INSTALLING SIGNS SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL UNDERGROUND UTILITIES. 5. SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO ENSURE AN UNOBSTRUCTED VIEW OF EACH SIGN. LEGEND NOTES S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP NTS STRIPING LEGEND PAVEMENT MARKING LEGEND SIGNING LEGEND 1 4" SOLID WHITE LINE 2 DOUBLE YELLOW LINE (2) 4" SOLID LINES 4" APART PREFORMED PLASTIC PAVEMENT MARKING 1.5' x 9' CROSSWALK LINES PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING SIGNING AND STRIPING PLAN C705 N/A 40' 1. ALL SIGNAGE SHALL BE PER CITY OF FORT COLLINS STANDARDS AND THESE PLANS OR AS OTHERWISE SPECIFIED IN MUTCD. 2. EPOXY APPLICATIONS SHALL BE APPLIED AS SPECIFIED IN CDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. 3. ALL SURFACES SHALL BE THOROUGHLY CLEANED PRIOR TO INSTALLATION OF STRIPING OR MARKINGS. 4. THE DEVELOPER INSTALLING SIGNS SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL UNDERGROUND UTILITIES. 5. SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO ENSURE AN UNOBSTRUCTED VIEW OF EACH SIGN. LEGEND NOTES S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP NTS STRIPING LEGEND PAVEMENT MARKING LEGEND SIGNING LEGEND 1 4" SOLID WHITE LINE 2 DOUBLE YELLOW LINE (2) 4" SOLID LINES 4" APART PREFORMED PLASTIC PAVEMENT MARKING 1.5' x 9' CROSSWALK LINES PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING DRAINAGE PLAN C800 N/A CHECKED BY: 60' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 00 60' 120' SCALE: 1" = 60' 30' 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. VEGETATIVE SWALES, PERMEABLE PAVERS AND THE POROUS LANDSCAPE DETENTION SHALL BE MAINTAINED BY THE PROPERTY OWNER OR HOA AND FOLLOW APPLICABLE STANDARD OPERATING PROCEDURES AS SHOWN IN DRAINAGE REPORT FOR REGISTRY RIDGE SEVENTH FILING. LEGEND NOTES D-101 BASIN DESIGNATION BASIN AREA (ACRE) 2 - YR RUNOFF COEFF. 100 - YR RUNOFF COEFF. BASIN BOUNDARY DESIGN POINT FLOW DIRECTION DRAINAGE SUMMARY Basin Design Point Area %I C2 C100 Q2 Q100 PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING SERVER DESINIT PATH DRAWING DATE TIME MGRINIT CONSTRUCTION DETAILS SITE/ROADWAY C900 N/A N/A 2"R. 1 1/2"R. 2'-6" 6" 4 1/2" 30" 9" 4.5" 18" 3.63" 21.75" R 0.13" 7" 2" 3.75" 12" ROLL-OVER VERTICAL (LOVELAND) Gutter edge may be tapered or battered. (Typical for all Curb & & Gutter Types) X=2' min. Driveway Width Varies 6" Lip FL Back of curb Right of Way line Detached Sidewalk PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING SERVER DESINIT PATH DRAWING DATE TIME MGRINIT CONSTRUCTION DETAILS SITE/ROADWAY C901 N/A N/A Sidewalk Driveway LIP F.L. T.C. DRIVEWAY SIDEWALK SECTION A-A NOTE: 1. Sidewalk grade shall remain consistent across driveway 3. This detail applies to Residential & Commercial driveways. 6" 6" Residential Detached Sidewalk Attached Sidewalk 1/2" Expansion Joint Material 1/2" Expansion Joint Material A A 2. For driveway design requirements, see CONST. DWG. 706 & 707. DETACHED ATTACHED 3'-0" 6'-0" All Sidewalk Thickness Shall Be 6" minimum. Min. SIDEWALK 8" Commercial (FORT COLLINS ONLY) NO PARKING BY ORDER OF THE FIRE MARSHAL PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING SERVER DESINIT PATH DRAWING DATE TIME MGRINIT CONSTRUCTION DETAILS SITE/ROADWAY C902 N/A N/A Note: 1. Set ramp slopes using the center of the ramp. 2. Truncated dome warning panel: Install panels along with the concrete pour for the ramp. The panel material shall be "Cast In Tact Warning Panels" or an equivalent material that must be first approved by the City Engineer, prior to installation. The panel color shall be red, no other color is approved. Specifications for the panel material will be provided upon request. 3. Each ramp shall align perpendicular to the street in which the ramp is provided to cross. 4. Refer to standard drawing 1606 in the Laimer County urban area street standards for other necessary criteria needed to construct these ramps that is not specified on this drawing. 5. Construct the ramps and walk so the corner area all drains to the street. 0.5' Full height Curb PT Curb 0" Curb Flowline 6" Curb 0" Curb 6" Curb 2'-0" Varies 2'-0" 2'-0" Varies 6" Ramp Width: PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING SERVER DESINIT PATH DRAWING DATE TIME MGRINIT CONSTRUCTION DETAILS WATER C903 N/A N/A NOT TO SCALE 1 C903 2" SQUARE OPERATING NUT, OPEN LEFT PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING SERVER DESINIT PATH DRAWING DATE TIME MGRINIT CONSTRUCTION DETAILS SANITARY SEWER C904 N/A N/A PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING SERVER DESINIT PATH DRAWING DATE TIME MGRINIT CONSTRUCTION DETAILS DRAINAGE C905 N/A N/A APPROVED: DATE: DRAWN BY: NBJ 12/18/00 APPROVED: DATE: DRAWN BY: 1/12/00 SKC STANDARD CONCRETE NOTES APPROVED: DATE: DRAWN BY: 2/22/05 TDC APPROVED: DATE: DRAWN BY: 11/8/00 NBJ APPROVED: DATE: DRAWN BY: NJB 11/9/00 PLAN A A C B B C SECTION A-A PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING CONSTRUCTION DETAILS DRAINAGE C906 N/A N/A DWG SIZE A SCALE 1:1 SHEET 1 OF 1 DWG NO. 7001-110-011 REV E 3130 VERONA AVE BUFORD, GA 30518 PHN (770) 932-2443 FAX (770) 932-2490 www.nyloplast-us.com 8 IN - 30 IN SPECIFICATIONS TITLE PROJECT NO./NAME MATERIAL DATE APPD BY DATE 3-10-00 DRAWN BY CJA 3-10-00 CJA Section 2721 Engineered Surface Drainage Products GENERAL PVC surface drainage inlets shall include the drain basin type as indicated on the contract drawing and referenced within the contract specifications. The ductile iron grates for each of these fittings are to be considered an integral part of the surface drainage inlet and shall be furnished by the same manufacturer. The surface drainage inlets shall be as manufactured by Nyloplast, a division of Advanced Drainage Systems, Inc., or prior approved equal. MATERIALS The drain basins required for this contract shall be manufactured from PVC pipe stock, utilizing a thermo-molding process to reform the pipe stock to the specified configuration. The drainage pipe connection stubs shall be manufactured from PVC pipe stock and formed to provide a watertight connection with the specified pipe system. This joint tightness shall conform to ASTM D3212 for joints for drain and sewer plastic pipe using flexible elastomeric seals. The flexible elastomeric seals shall conform to ASTM F477. The pipe bell spigot shall be joined to the main body of the drain basin or catch basin. The raw material used to manufacture the pipe stock that is used to manufacture the main body and pipe stubs of the surface drainage inlets shall conform to ASTM D1784 cell class 12454. The grates and frames furnished for all surface drainage inlets shall be ductile iron for sizes 8", 10", 12", 15", 18", 24", and 30" and shall be made specifically for each basin so as to provide a round bottom flange that closely matches the diameter of the surface drainage inlet. Grates for drain basins shall be capable of supporting H-20 wheel loading for traffic areas or H-10 loading for pedestrian areas. 12" and 15" square grates will be hinged to the frame using pins. Metal used in the manufacture of the castings shall conform to ASTM A536 grade 70-50-05 for ductile iron. Grate shall be provided painted black. INSTALLATION The specified PVC surface drainage inlet shall be installed using conventional flexible pipe backfill materials and procedures. The backfill material shall be crushed stone or other granular material meeting the requirements of class 2 material as defined in ASTM D2321. Bedding and backfill for surface drainage PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING SERVER DESINIT PATH DRAWING DATE TIME MGRINIT CONSTRUCTION DETAILS DRAINAGE C907 N/A N/A UPSTREAM NOT TO SCALE 1 C907 DOWNSTREAM TOP VIEW HEADWALL FRONT VIEW (TYP. BOTH SIDES) 6" THICK WINGWALL AND FOOTER WITH NO. 4 REBAR @ 12" O.C. VERT. AND HORIZ. CENTERED WITHIN WALL ELEV.=5069.20 ELEV.=5068.00 15" ELEV.=5065.46 ELEV.=5065.46 EXPANSION JOINT MATERIAL OPTIONAL MATERIAL REBAR FROM WINGWALL FOOTING CONTINUE INTO OUTLET WALL ƒ 6" 6" TOP OF WINGWALL 8' 18" 18" TOP VIEW HEADWALL FRONT VIEW (TYP. BOTH SIDES) 6" THICK WINGWALL AND FOOTER WITH NO. 4 REBAR @ 12" O.C. VERT. AND HORIZ. CENTERED WITHIN WALL PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING SERVER DESINIT PATH DRAWING DATE TIME MGRINIT CONSTRUCTION DETAILS EROSION CONTROL C908 N/A N/A SF APPROVED: DATE: DRAWN BY: 12/27/00 NBJ APPROVED: DATE: DRAWN BY: NBJ 11-29-2000 APPROVED: DATE: DRAWN BY: 01/03/01 NBJ IP PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING SERVER DESINIT PATH DRAWING DATE TIME MGRINIT CONSTRUCTION DETAILS EROSION CONTROL C909 N/A N/A CWA VEHICLE CONTROL TRACKING PAD NOT TO SCALE CONCRETE WASHOUT AREA NOT TO SCALE 1 C909 2 C909 WATTLE INSTALLATION DETAIL NOT TO SCALE 3 C909 VTC ROCK SOCK NOT TO SCALE 4 C909 ELEV.=5069.05 ELEV.=5067.75 15" ELEV.=5065.22 ELEV.=5065.22 EXPANSION JOINT MATERIAL OPTIONAL MATERIAL REBAR FROM WINGWALL FOOTING CONTINUE INTO OUTLET WALL ƒ 6" 6" TOP OF WINGWALL 8' 18" 18" FINISHED GRADE ELEV.=5067.22 FINISHED GRADE ELEV.=5067.46 inlets shall be placed and compacted uniformly in accordance with ASTM D2321. The drain basin body will be cut at the time of the final grade. No brick, stone or concrete block will be required to set the grate to the final grade height. For H-20 load rated installations, a concrete ring will be poured under and around the grate and frame. The concrete slab must be designed taking into the consideration local soil conditions, traffic loading, and other applicable design factors. For other installation considerations such as migration of fines, ground water, and soft foundations refer to ASTM D2321 guidelines. DWG SIZE A SCALE 1:8 SHEET 1 OF 1 DWG NO. 7001-110-211 REV B 3130 VERONA AVE BUFORD, GA 30518 PHN (770) 932-2443 FAX (770) 932-2490 www.nyloplast-us.com 15 IN DOME GRATE ASSEMBLY TITLE PROJECT NO./NAME MATERIAL DATE APPD BY DATE 3-7-06 THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH DRAWN BY EBC NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT OR POSSESSION OF THIS PRINT DOES NOT CONFER, TRANSFER, OR LICENSE THE USE OF THE DESIGN OR TECHNICAL INFORMATION SHOWN HEREIN REPRODUCTION OF THIS PRINT OR ANY INFORMATION CONTAINED HEREIN, OR MANUFACTURE OF ANY ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN PERMISSION FROM NYLOPLAST. 3-7-06 CJA 1599CGD APPROX. DRAIN AREA = 115.49 SQ IN APPROX. WEIGHT WITH FRAME = 47.30 LBS 6.00 2.47 ‘ ‘ ALL DIMENSIONS IN INCHES UNLESS NOTED OTHERWISE QUALITY: MATERIAL SHALL CONFORM TO ASTM A536 GRADE 70-50-05 PAINT: CASTINGS ARE FURNISHED WITH A BLACK PAINT LOCKING DEVICE AVAILABLE UPON REQUEST SEE DRAWING NO. 7001-110-230 DUCTILE IRON .93 NOT TO SCALE 2 C906 NYLOPLAST DRAIN BASIN DETAILS NOT TO SCALE 1 CDOT TYPE R INLET DETAILS C906 DWG SIZE A SCALE 1:40 SHEET 1 OF 1 DWG NO. 7001-110-144 REV D 3130 VERONA AVE BUFORD, GA 30518 PHN (770) 932-2443 FAX (770) 932-2490 www.nyloplast-us.com DRAIN BASIN WITH STANDARD GRATE QUICK SPEC INSTALLATION DETAIL TITLE PROJECT NO./NAME MATERIAL DATE APPD BY DATE 1-23-06 DRAWN BY EBC 1-23-06 CJA 5 ADAPTER ANGLES 9$5,$%/(ƒƒ ACCORDING TO PLANS A 18" MIN WIDTH GUIDELINE 8" MIN THICKNESS GUIDELINE 3 VARIABLE SUMP DEPTH ACCORDING TO PLANS (6" MIN ON 8" - 24", 10" MIN ON 30") 4" MIN ON 8" - 24" 6" MIN ON 30" MINIMUM PIPE BURIAL DEPTH PER PIPE MANUFACTURER RECOMMENDATION 3 VARIABLE INVERT HEIGHTS AVAILABLE (ACCORDING TO PLANS/TAKE OFF) THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS II MATERIAL AS DEFINED IN ASTM D2321. BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321. 4 VARIOUS TYPES OF INLET & OUTLET ADAPTERS AVAILABLE: 4" - 30" FOR CORRUGATED HDPE (ADS N-12, ADS SINGLE WALL, HANCOR DUAL WALL), SDR 35, SCH 40 DWV, CORRUGATED & RIBBED PVC WATERTIGHT JOINT (CORRUGATED HDPE SHOWN) NYLOPLAST DRAIN BASIN 1 - 8" - 30" GRATES/SOLID COVERS SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05, WITH THE EXCEPTION OF THE 8" - 15" BRONZE GRATES 2 - 12" - 30" FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS. RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO SHIPPING RESTRICTIONS. SEE DRAWING NO. 7001-110-065 4 - DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212 FOR CORRUGATED HDPE (ADS & HANCOR DUAL WALL) & SDR 35 PVC $'$37(56&$1%(02817('21$1<$1*/(ƒ72ƒ72'(7(50,1(0,1,080$1*/( BETWEEN ADAPTERS SEE DRAWING NO. 7001-110-012, 7001-110-013, & 7001-110-014. 6 - GRATES SHALL MEET H-10 LOAD RATING FOR 12" - 24" PED 7 - GRATES SHALL MEET H-20 LOAD RATING FOR 30" PED & 12" - 30" STD & SOLID 8 - ALL BRONZE GRATES, DROP IN GRATES, & 8" & 10" PED/STD GRATES & SOLID COVERS ARE RATED FOR LIGHT DUTY APPLICATIONS ONLY 9 - DOME GRATES HAVE NO LOAD RATING TRAFFIC LOADS: CONCRETE SLAB DIMENSIONS ARE FOR GUIDELINE PURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE DESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS, TRAFFIC LOADING, & OTHER APPLICABLE DESIGN FACTORS. 1 2 INTEGRATED DUCTILE IRON FRAME & GRATE TO MATCH BASIN O.D. SECTION B-B SECTION C-C DETAIL 1 APPROVED: DATE: DRAWN BY: NBJ 1/28/09 NOTES: 1. TO BE USED FOR POROUS LANDSCAPE DETENTION PONDS. 2. IMPERVIOUS MEMBRANE NOT REQUIRED FOR PONDS. 3. PLACE PERFORATED DRAINS PER PLANS. 4.5' 5.0' 6.0' 7.0' 8.0' Note: Truncated dome panels are available in 2'x2' squares and 2'x2.5' rectangles. Combine the widths to fit the ramp. Panels may be cut to no less than a 2'x1.5' size. Panel Width Combinations: 2'+2.5' 2.5'+2.5' 2'+2'+2' 2.5'+2'+2.5' 2'+2'+2'+2' Note: 1. Truncated dome warning panel: Install panels along with the concrete pour for the ramp. The panel material shall be "Cast In Tact Warning Panels" or an equivalent material that must be first approved by the City Engineer prior to installation. The panel color shall be red, no other color is approved. Specifications for the panel and installation instructions will be provided upon request. 2. This drawing shows vertical curb. For Drive Over Curb the warning detection location shall be placed in the same position 6" back from the Face of Curb or . Varies 2'-0" 6" 6" 2' 12" (Water & Sewer) If this section is less than 4' of existing asphalt/concrete, it must be removed and replaced. Edge of Pavement or Lip of Existing Gutter Compacted Lifts of Suitable Materials (See Note 9 below for Storm.) 4" (min.) 6" (max.) Trench Width Varies 2' (min.) Bedding Material Undisturbed Soil Utility Conduit New Asphalt/Concrete Clean Road Base Existing Road Base 6" Full Depth Asphalt or X/Y Composite Section NOTES: 1. All trenches shall be backfilled in accordance with the above detail unless otherwise specified by the Local Entity Engineer. 2. Prior to placement of asphalt/concrete, pavement edge shall be saw cut to a clean, vertical, and straight edge. 3. Where the surrounding soils are non-expansive, a sand/cement slurry (1 sack mix) may be substituted for backfill material. 4. Trench width shall not be more than 16" nor less than 12" wider than the outside diameter of the pipe. 5. Use a #4 rebar at centers along the perimeter of concrete replacement sections. 6. Refer to Chapter 22, Materials & Construction Specifications for compaction and testing requirements. 7. In unimproved areas, all disturbed areas shall be regraded, seeded & mulched. 8. In concrete roadways, a minimum of one entire concrete panel must be replaced. 9. Bedding material depth when installing storm sewer shall be up to spring line, except in areas of unsuitable backfill; then, bedding material shall be placed to a level 12" above pipe. 1 C902 NOT TO SCALE 6" 2"R. 6" 6" 12" 1 1/2"R. 6" 4 1/2" ONSITE VERTICAL CURB & GUTTER Gutter edge may be tapered or battered. (Typical for all Curb & & Gutter Types) OUT FALL CURB & GUTTER 1" 1'-6" 6" 2"R. 1 1/2"R. 6" 4 1/2" Gutter edge may be tapered or battered. (Typical for all Curb & & Gutter Types) 1" 1'-6" 6" 6" 12" 1" 2' CONCRETE PAN 2' 6" CONCRETE NOTES: 1. THE ABOVE PAVEMENT SECTION WAS TAKEN FROM THE TERRACON REPORT ENTITLED "GEOTECHNICAL ENGINEERING REPORT, REGISTRY RIDGE P.U.D.-2ND FILING, FORT COLLINS, CO", DATED JULY 25, 2006, TERRACON PROJECT NO. 20065097. REFER TO THIS REPORT FOR PERFORMANCE SPECIFICATIONS AND OTHER RECOMMENDATIONS. 2. CONTRACTOR SHALL NOTE THAT, PER THE REFERENCED GEOTECHNICAL REPORT, THE ABOVE REFERENCED PAVEMENT SECTION IS PRELIMINARY IN NATURE AND FOR BIDDING/PLANNING PURPOSES ONLY. CONTRACTOR SHALL CONTRACT A GEOTECHNICAL ENGINEER TO PROVIDE A FINAL PAVEMENT SECTION DESIGN AFTER UNDERGROUND UTILITIES ARE INSTALLED AND SUBGRADE IS CUT TO ROUGH GRADE. 3. PERMEABLE PAVER COLOR SHALL BE ANTIQUE TERRA COTTA (OR APPROVED AREA) LAID IN HERRING BONE PATTERN. 4" HOT MIX ASPHALT 6" AGGREGATE BASE COURSE (CLASS 6) 12" TREATED SUBGRADE (SEE GEOTECHNICAL REPORT) NOT TO SCALE 3 C902 PAVEMENT 8" 1'-2" #5 REBAR T&B 8" RIBBON CURB 12" SUB-BASE (#2 ROCK) 1/8" HAND TIGHT JOINTS 4" BASE (#57 BASE) 2" BEDDING (CRUSHED #8 ROCK) ECO-PRIORA STONE BY PAVESTONE OR APPROVED EQUAL EDGE RESTRAINT (DRIVE-OVER CURB & GUTTER, SEE DETAIL) EDGE RESTRAINT (RIBBON CURB, SEE DETAIL) MINIMUM 30-MIL HDPE IMPERVIOUS MEMBRANE PERMEABLE PAVER SECTION (SEE PAVEMENT SECTION DETAIL) 4" PERFORATED PVC PIPE SUB-DRAIN (SLOPE W/ STREET GRADE) NOT TO SCALE 2 C902 MINIMUM 30-MIL HDPE IMPERVIOUS MEMBRANE SUB-GRADE ATTACHED SIDEWALK DETAIL NOTE: Construct sidewalk with joints at 10' intervals R 1/8" WEAKENED PLANE JOINT EXPANSION JOINT R1/4" and aligned with scoring on curb. INSTALL IN LOCATIONS SPECIFIED IN CHAPTER 22 1/2" 1/4" 1/4 SLAB THICKNESS 1/4" 1/2" Expansion Joint material DETACHED SIDEWALK DETAIL Variable Landscaping 2' min. Slope: Minimum 1 4"/ft Maximum 3"/ft SLOPE TO UNDERDRAIN STANDARD FIRE LANE SIGN DETAIL UNIVERSAL FIRE LANE SIGN DETAIL NOT TO SCALE 12 C901 24" 1" RADIUS (TYP.) NOTE: 1. BOLT SIGN THROUGH POST TOP AND BOTTOM. 2" LETTERING WITH HELV NARROW FONT 4" LETTERING WITH HELV NARROW FONT RESIDENTS 30" & GUESTS ONLY NOT TO SCALE 1 C901 NOTE: 1. BOLT SIGN THROUGH POST TOP AND BOTTOM. 2" LETTERING WITH HELV NARROW FONT 1-1/2" LETTERING WITH HELV NARROW FONT 12" 1" RADIUS (TYP.) 18" NOTE: 1. Concrete driveway must be provided to the property line. Refer to Chapter 25 for minimum removal dimensions. X Y W X W = Width t N.T.S. SECTION A-A 2" t t X = Curb Transition Length Y = Parkway Width in Type I Approach W = Driveway Width (See Drawing 707) t = Concrete Thickness - minimum 6" Type I = With Detached Sidewalk Type II = With Attached Sidewalk TYPE I TYPE II A A PERSPECTIVE X=6'-0" B B WALK Y t t WALK JOINT EXPANSION SECTION B-B N.T.S. Ramp if necessary 1:12 max. Expansion joint if drive continues as concrete WALK 6" W ASPHALT W W P.C. CROSSPAN THICKENED ASPHALT THICKENED AND WALK CURB, GUTTER T = THICKNESS OF CROSSPAN W = WIDTH OF CROSSPAN P.C. *-If subgrade is flyash treated, use T instead of 2T. Single Family 12' 24' Commercial I, II, III, or IV Multi Family 24' 36' 24' 36' Industrial 24' 36' I, II, III, or IV I or II RESIDENTIAL: * * * * * High volume driveways (Type III or IV) allowed for 350 30' maximum for 3 car garages. No single opening shall exceed 36'. Wider driveways shall be divided w/a median not less than 6' wide. or greater trip ends/day. * * * ɕ ɕ Arterial 10' 1 1/4" 1 1/2" Collector 8' 1" 1 1/8" Local 6' 3/4" 1 1/2" 7/8" 2 1/2" 2" 1. Attach the sign panels tightly to the post and use oversized washers to keep the sign from breaking loose from the post when hit by a vehicle. 2. Sign panels should be mounted a minimum of 7 feet above the pavement or ground. Cross section of post 2 1/4" Anchor 3. Signs larger than 36 inches in length or width require wind bracing and special post design. NOTES: 4. Anchor Stub and post are square steel tube (perforated). CRITERIA FOR SINGLE POST $OO1R3DUNLQJVLJQVVKDOOEHLQVWDOOHGDWƒIURP)ORZ/LQH * * 2" x 2" x 10' OR 12' 12 GAUGE TELESPAR POST (22F12A31) 2' - 3' FROM F Street Curb See Figure 16-1 R1-1 "STOP" SIGN 30" HIGH DENSITY/DIAMOND GRADE. SIGN MOUNTED TO POST WITH 1 EACH DRIVE RIVET WITH NYLON WASHER AGAINST SIGN FACE (ON TOP OF THE SIGN). THE BOTTOM OF THE SIGN SHALL BE MOUNTED WITH 1 EACH 5/16"x2-1/2" HEW BOLT WITH METAL AND FROM NYLON WASHERS (NYLON WASHER AGAINST SIGN FACE) AND SECURED WITH 1 EACH 5/16" HEX NUT ON THE BACK SIDE OF POST. L 2-1/4" x 2-1/4" x 3' ANCHOR/STUB 2 EACH 8" BLADES MOUNTED TO POST WITH 4 EACH DRIVE RIVETS WITH NYLON WASHERS * 12 Gauge (acre) (cfs) (cfs) Proposed Basins -Northeast Site A1 A1 0.17 49% 0.62 0.78 0.30 1.29 A2 A2 0.43 52% 0.64 0.80 0.79 3.45 A3 A3 0.19 54% 0.65 0.81 0.34 1.50 A4 A4 0.63 18% 0.38 0.48 0.68 2.98 Proposed Basins -North Central Site B1 B1 0.14 2% 0.25 0.31 0.10 0.45 B2 B2 0.89 57% 0.67 0.84 1.70 7.42 B3 B3 0.48 44% 0.57 0.72 0.78 3.42 B4 B4 0.76 60% 0.71 0.88 1.36 5.92 Existing Basins -Adjacent to North Central Site 1D 1D 0.51 69% 0.76 0.95 1.09 4.77 1E 1E 0.09 48% 0.62 0.77 0.15 0.67 Proposed Basins -South Site C1 C1 0.62 46% 0.59 0.74 0.75 3.29 C2 C2 0.45 57% 0.67 0.84 0.87 3.78 C3 C3 0.34 59% 0.69 0.86 0.66 2.89 C4 C4 1.14 52% 0.64 0.79 2.07 9.02 C5 C5 0.97 60% 0.69 0.86 1.90 8.31 C6 C6 0.91 33% 0.50 0.62 1.29 5.63 C7 C7 0.09 46% 0.60 0.75 0.11 0.47 C8 C8 1.05 40% 0.55 0.68 1.63 7.13 C9 C9 0.86 36% 0.52 0.65 1.27 5.55 C10 C10 0.71 29% 0.47 0.59 0.95 4.13 C11 C11 0.88 22% 0.41 0.51 1.03 4.47 C12 C12 0.13 2% 0.25 0.31 0.09 0.38 Onsite Total 11.83 43% 0.56 0.70 18.67 81.49 A4 A1 C8 C3 C4 C5 C6 C9 S8 C7 C11 C10 C12 POROUS LANDSCAPE DETENTION POROUS LANDSCAPE DETENTION HORNET DRIVE ENTERPRISE DRIVE CABOT COURT NIMITZ DRIVE (PRIVATE DRIVE) SAIPAN COURT PROPOSED STORM INLET PROPOSED STORM DRAIN LINE 3 PROPOSED STORM DRAIN LINE 6 PROPOSED STORM INLETS PROPOSED STORM INLET CURB CUT AND SIDEWALK CHASE CURB CUT AND SIDEWALK CHASE CURB CUT AND SIDEWALK CHASE PROPOSED STORM DRAIN LINE 2 PROPOSED POND OVERFLOW STRUCTURE CURB CUT AND SIDEWALK CHASE PERMEABLE PAVERS WITH UNDERDRAIN CITY HIGH RISK FLOODWAY PROPOSED STORM DRAIN LINE 5 PROPOSED STORM DRAIN LINE 1 KITTY HAWK COURT (PRIVATE DRIVE) (PRIVATE DRIVE) CABOT COURT (PRIVATE DRIVE) PROPOSED STORM DRAIN LINE 4 STOP R1-1 30" X 30" A B C 3 4" BROKEN WHITE LINE 2' SEGMENTS WITH 4' GAPS NO PARKING BY ORDER OF THE FIRE MARSHAL D R1-2 36" X 36" E F RESIDENTS & GUESTS ONLY CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 40' 80' SCALE: 1" = 40' 20' 3 1 2 2 1 2 2 EXISTING SPEED LIMIT SIGN KITTY HAWK COURT (PRIVATE DRIVE) 1 RELOCATE EXISTING STOP SIGN 14' 3 1 14' 14' HORNET DRIVE CABOT COURT (PRIVATE DRIVE) CABOT COURT (PRIVATE DRIVE) BLOCK 4 BLOCK 4 BLOCK 4 BLOCK 5 BLOCK 6 BLOCK 7 BLOCK 8 BLOCK 9 BLOCK 10 LOT 14 LOT 13 OUTLOT B LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 10 LOT 9 LOT 8 OUTLOT C LOT 7 LOT 6 LOT 5 LOT 4 LOT 3 LOT 1 LOT 2 LOT 4 LOT 3 LOT 2 LOT 1 LOT 2 LOT 3 LOT 4 LOT 1 TRACT C LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 1 TRACT D LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 BLOCK 8 STOP R1-1 30" X 30" A B C 3 4" BROKEN WHITE LINE 2' SEGMENTS WITH 4' GAPS NO PARKING BY ORDER OF THE FIRE MARSHAL D R1-2 36" X 36" E F RESIDENTS & GUESTS ONLY CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 40' 80' SCALE: 1" = 40' 20' 3 1 2 2 1 2 2 EXISTING SPEED LIMIT SIGN KITTY HAWK COURT (PRIVATE DRIVE) 1 RELOCATE EXISTING STOP SIGN SAIPAN COURT (PRIVATE DRIVE) 14' 3 1 14' 14' BLOCK 1 BLOCK 3 BLOCK 2 BLOCK 4 BLOCK 4 BLOCK 4 BLOCK 5 BLOCK 9 LOT 1 OUTLOT A LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 1 LOT 2 LOT 3 LOT 4 LOT 1 LOT 2 LOT 3 LOT 5 LOT 4 LOT 6 TRACT B LOT 14 LOT 13 OUTLOT B LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 10 LOT 9 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 TRACT A BLOCK 8 BLOCK 4 BLOCK 4 BLOCK 4 LOT 6 LOT 5 LOT 4 LOT 3 TRACT B LOT 14 LOT 13 LOT 1 OUTLOT B LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 (PRIVATE DRIVE) KITTY HAWK COURT 0.6% 0.7% 1.6% 1.4% 1.5% 0.3% 2.0% 0.6% 0.7% 0.6% 0.8% 0.8% 2.0% 1.5% 1.6% 1.8% 1.6% 2.7% 1.8% 1.8% 2.7% 1.8% 2.8% 0.4% 0.4% 0.5% 0.7% 0.5% 2.2% ENTERPRISE DRIVE NIMITZ DRIVE 3' TRANSITION FROM FLUSH TO VERTICAL INFLOW CURB & GUTTER END RIBBON CURB AND BEGIN VERTICAL CURB & GUTTER END VERTICAL OUTFALL CURB & GUTTER AND BEGIN RIBBON CURB END ROLLOVER CURB & GUTTER BEGIN VERTICAL OUTFALL CURB & GUTTER 2' CURB CUT 2' CURB CUT 3' TRANSITION FROM FLUSH TO VERTICAL OUTFALL CURB & GUTTER TRANSITION FROM ROLLOVER CURB & GUTTER TO VERTICAL OUTFALL CURB & GUTTER GRADES MATCH EXISTING PAVEMENT GRADES BLOCK 2 LOT 3 LOT 4 LOT 1 LOT 2 (PRIVATE DRIVE) SAIPAN COURT 1.7% ENTERPRISE DRIVE 3' TRANSITION FROM FLUSH TO ROLLOVER CURB & GUTTER LOT 1 LOT 2 CABOT COURT TRACT C (PRIVATE DRIVE) 1.4% 2.6% 2.9% 2.8% 0.7% 0.6% 3.4% 1.0% 2.4% 2.0% END RIBBON CURB BEGIN ROLLOVER CURB & GUTTER INTERSECTION DETAIL NOTE: ALL STATIONS AND OFFSETS ARE BASED ON THE ENTERPRISE DRIVE ALIGNMENT UNLESS OTHERWISE NOTED 11+00 10+00 9+00 LOT 3 LOT 4 LOT 7 LOT 8 LOT 1 LOT 2 STA: 10+48.09 (0.00', ) EL=76.22 STA: 10+88.12 (0.00', ) EL=75.58 STA: 10+63.29 (15.00', R) EL=75.63 STA: 10+42.28 (26.45', R) EL=76.05 STA: 10+63.33 (15.00', L) EL=75.60 STA: 10+42.29 (26.46', L) EL=75.96 STA: 10+88.12 (15.00', R) EL=75.22 STA: 10+88.12 (15.00', L) EL=75.24 STA: 10+64.20 (26.50', L) EL=76.24 STA: 10+68.74 (26.50', L) EL=76.10 STA: 10+53.06 (31.26', L) EL=76.59 STA: 10+50.77 (33.78', L) EL=76.69 STA: 10+37.82 (48.05', L) EL=76.55 STA: 10+49.40 (35.56', R) EL=76.74 STA: 10+53.74 (31.00', R) EL=76.55 STA: 10+64.24 (26.50', R) EL=76.20 STA: 10+68.74 (26.50', R) EL=76.13 STA: 10+37.76 (47.80', R) EL=76.69 STA: 10+25.35 (51.35', L) EL=75.84 STA: 10+24.94 (61.52', L) EL=75.79 STA: 10+24.96 (67.13', L) EL=75.76 STA: 10+34.14 (69.55', L) EL=76.29 STA: 10+34.09 (61.48', L) EL=76.28 STA: 10+34.08 (57.17', L) EL=76.31 STA: 10+33.69 (72.42', R) EL=76.37 STA: 10+24.70 (67.51', R) EL=75.85 STA: 10+33.74 (61.35', R) EL=76.39 STA: 10+33.78 (57.07', R) EL=76.45 STA: 10+24.83 (54.88', R) EL=75.93 STA: 10+24.76 (61.37', R) EL=75.89 1.6% 1.4% 1.7% 1.7% 1.6% 1.4% 1.4% BON HOMME RICHARD DRIVE NIMITZ DRIVE (SEE SHEETS C700 & C701) NIMITZ DRIVE STA: 9+74.62 (51.39', L) EL=75.87 STA: 9+75.16 (61.69', L) EL=75.66 STA: 9+70.52 (61.70', L) EL=76.05 STA: 9+66.13 (61.72', L) EL=76.14 STA: 9+62.30 (45.07', L) EL=76.34 STA: 9+50.95 (32.34', L) EL=76.63 STA: 9+47.43 (19.47', L) EL=76.07 STA: 9+32.89 (27.35', L) EL=76.88 STA: 9+29.01 (26.86', L) EL=76.89 STA: 9+13.45 (23.45', L) EL=76.91 STA: 9+13.45 (18.41', L) EL=76.45 18+00 19+00 19+75 LOT 11 LOT 12 LOT 10 LOT 9 LOT 9 LOT 10 BON HOMME RICHARD DRIVE ENTERPRISE DRIVE (SEE SHEETS C700 & C701) ENTERPRISE DRIVE STA: 18+78.28 (47.94', L) EL=73.89 STA: 18+69.15 (55.96', L) EL=74.65 STA: 18+69.11 (45.96', L) EL=74.34 STA: 18+69.09 (41.44', L) EL=74.31 STA: 18+78.24 (39.88', L) EL=73.84 STA: 18+76.07 (14.93', L) EL=73.65 STA: 18+63.74 (30.01', L) EL=74.49 STA: 18+53.25 (26.50', L) EL=74.35 STA: 18+53.24 (15.00', L) EL=73.77 STA: 18+48.75 (15.00', L) EL=73.82 STA: 18+48.75 (26.50', L) EL=74.37 STA: 18+26.53 (15.00', L) EL=74.06 STA: 18+26.53 (0.00', ) EL=74.45 STA: 18+26.53 (15.00', R) EL=74.06 STA: 18+48.50 (15.00', R) EL=73.69 STA: 18+48.50 (26.50', R) EL=74.27 STA: 18+53.00 (26.50', R) EL=74.19 STA: 18+53.08 (15.00', R) EL=73.61 STA: 18+64.05 (30.56', R) EL=74.15 STA: 18+78.00 (40.11', R) EL=73.34 STA: 18+77.96 (47.81', R) STA: 18+75.98 (15.07', R) EL=73.28 EL=73.48 STA: 18+68.78 (41.34', R) EL=73.81 STA: 18+68.77 (45.79', R) EL=73.78 STA: 18+68.63 (55.79', R) EL=73.94 2.0% 2.0% 1.1% 1.7% 1.7% 1.1% 0.6% 0.5% 0.7% 0.6% 0.6% STA: 19+27.89 (46.05', L) EL=73.87 STA: 19+27.86 (42.07', L) EL=73.85 STA: 19+33.02 (46.10', L) EL=74.30 STA: 19+47.52 (28.38', L) EL=74.76 STA: 19+47.76 (21.94', L) EL=74.08 STA: 19+54.01 (21.91', L) EL=74.13 STA: 19+55.35 (33.03', L) EL=74.96 STA: 19+28.67 (22.03', L) EL=73.65 STA: 19+28.68 (20.14', L) EL=73.64 STA: 19+28.77 (19.79', R) EL=73.35 STA: 19+28.78 (21.92', R) EL=73.34 STA: 19+27.59 (40.59', R) EL=73.24 STA: 19+27.54 (47.91', R) EL=73.20 STA: 19+32.50 (45.92', R) EL=73.62 STA: 19+37.32 (45.96', R) EL=73.72 STA: 19+55.34 (30.97', R) EL=74.50 STA: 19+52.02 (26.49', R) EL=74.34 STA: 19+54.02 (21.87', R) EL=74.00 STA: 19+47.56 (21.87', R) EL=73.87 1.0% 0.5% 2.2% 2.8% 0.8% 2.0% 17+00 18+00 LOT 9 LOT 8 LOT 7 LOT 7 LOT 8 LOT 8 LOT 9 LOT 10 ENTERPRISE DRIVE (SEE SHEETS C700 & C701) STA: 17+57.65 (15.00', L) EL=74.48 STA: 17+57.23 (22.00', L) EL=74.62 STA: 17+64.16 (22.00', L) EL=75.02 STA: 17+64.10 (26.50', L) EL=75.11 STA: 17+56.94 (26.50', L) EL=74.71 STA: 17+37.62 (15.00', L) EL=74.32 STA: 17+35.22 (26.50', L) EL=74.55 STA: 17+32.67 (36.93', L) EL=74.63 STA: 17+31.46 (41.31', L) EL=74.67 STA: 17+29.14 (22.00', L) EL=74.72 STA: 17+27.92 (26.50', L) EL=74.79 STA: 17+26.33 (27.00', L) EL=74.39 FL STA: 17+23.91 (27.30', L) EL=74.35 FL STA: 17+24.68 (15.00', L) EL=74.10 STA: 17+26.88 (15.00', L) EL=74.15 CABOT COURT (PRIVATE DRIVE) 3' TRANSITION FROM FLUSH TO ROLLOVER CURB & GUTTER 11+00 12+00 NIMITZ DRIVE (SEE SHEETS C700 & C701) LOT 4 LOT 7 LOT 8 LOT 1 LOT 1 LOT 2 CABOT COURT (PRIVATE DRIVE) STA: 11+43.85 (15.00', R) EL=74.31 STA: 11+43.59 (22.02', R) EL=74.45 STA: 11+38.29 (22.00', R) EL=74.90 STA: 11+38.26 (26.50', R) EL=74.99 STA: 11+43.42 (26.74', R) EL=74.54 STA: 11+42.72 (35.49', R) EL=74.73 STA: 11+45.28 (15.00', L) EL=74.29 STA: 11+45.69 (21.97', L) EL=74.43 STA: 11+45.99 (26.50', L) EL=74.52 STA: 11+38.82 (26.50', L) EL=74.98 STA: 11+38.82 (22.00', L) EL=74.89 STA: 11+63.07 (35.38', R) EL=74.44 STA: 11+64.30 (26.55', R) EL=74.26 STA: 11+64.97 (22.00', R) EL=74.17 STA: 11+66.08 (15.00', R) EL=74.03 STA: 11+68.18 (34.35', R) EL=74.96 STA: 11+69.49 (26.50', R) EL=74.36 STA: 11+74.78 (26.50', R) EL=74.52 STA: 11+75.69 (22.00', R) EL=74.43 STA: 11+70.27 (22.00', R) EL=74.27 STA: 11+65.31 (15.00', L) EL=74.04 STA: 11+76.03 (15.00', L) EL=73.91 STA: 11+78.23 (15.00', L) EL=73.89 STA: 11+76.60 (27.00', L) EL=74.15 FL STA: 11+75.01 (26.50', L) EL=74.53 STA: 11+73.79 (22.00', L) EL=74.46 STA: 11+71.48 (41.35', L) EL=74.43 STA: 11+70.27 (36.96', L) EL=74.38 STA: 11+66.78 (22.26', L) EL=74.19 STA: 11+79.02 (27.29', L) EL=74.13 FL STA: 11+46.63 (43.86', L) EL=74.89 3' TRANSITION FROM FLUSH TO ROLLOVER CURB & GUTTER 3' TRANSITION FROM FLUSH TO ROLLOVER CURB & GUTTER RIGHT-OF-WAY PROPOSED CURB & GUTTER S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP CENTERLINE 0 50' 100' SCALE: 1" = 50' 25' HORNET DRIVE PROFILES C701 5' CHECKED BY: 50' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: HORNET DRIVE_CL PROFILE 5060 5065 5070 5075 5080 5085 5090 5060 5065 5070 5075 5080 5085 5090 EG= FG= 9+50 EG= FG= 10+00 EG=5076.1 FG=5076.19 10+50 EG=5075.4 FG=5075.39 11+00 EG=5074.4 FG=5074.62 11+50 EG=5074.1 FG=5073.99 12+00 EG=5073.4 FG=5073.37 12+50 EG=5072.1 FG=5072.74 13+00 EG=5072.4 FG=5072.12 13+50 EG=5072.0 FG=5071.56 14+00 EG=5070.7 FG=5071.52 14+50 EG=5071.8 FG=5071.82 15+00 EG=5071.6 FG=5072.12 15+50 EG=5071.1 FG=5072.52 16+00 EG=5072.7 FG=5073.29 16+50 EG=5072.7 FG=5074.16 17+00 EG=5073.3 FG=5074.86 17+50 EG=5073.8 FG=5074.80 18+00 EG=5074.8 FG=5074.04 18+50 EG=5074.1 FG= 19+00 EG=5074.3 FG= 19+50 PVI STA = 10+48.12 PVI ELEV = 5076.22 PVI STA = 18+79.52 PVI ELEV = 5073.66 PVI STA = 18+71.53 PVI ELEV = 5073.66 110.0' VC HIGH PT EL: 5074.93 HIGH PT STA: 17+71.53 PVI STA: 17+71.53 PVI EL: 5075.41 AD: 3.50 K: 31.43 BVCS: 17+16.53 BVCE: 5074.45 EVCS: 18+26.53 EVCE: 5074.45 75.0' VC PVI STA: 16+00.59 PVI EL: 5072.42 AD: 1.15 K: 65.22 BCVS: 15+63.09 BVCE: 5072.20 ECVS: 16+38.09 EVCE: 5073.08 75.0' VC LOW PT EL: 5071.46 LOW PT STA: 14+28.10 PVI STA: 14+14.93 PVI EL: 5071.31 AD: 1.85 K: 40.54 BCVS: 13+77.43 BVCE: 5071.78 ECVS: 14+52.43 EVCE: 5071.53 PROPOSED GRADE EXISTING GROUND STA: 14+25.97 INV.= 5066.89' 24" STORM DRAIN -1.60% -1.25% -1.75% 0.60% 1.75% HORNET DRIVE_FL(LEFT) PROFILE 5065 5070 5075 5080 5085 5090 5065 5070 5075 5080 5085 5090 EG=5076.4 FG=5075.24 10+50 EG=5074.2 FG=5074.39 11+00 EG=5074.3 FG=5073.70 11+50 EG=5073.7 FG=5073.02 12+00 EG=5071.9 FG=5072.33 12+50 EG=5071.9 FG=5071.65 13+00 EG=5071.8 FG=5071.12 13+50 EG=5070.7 FG=5071.21 14+00 EG=5071.6 FG=5071.53 14+50 EG=5070.8 FG=5071.84 15+00 EG=5072.0 FG=5072.43 15+50 EG=5073.2 FG=5073.35 16+00 EG=5073.9 FG=5074.26 16+50 EG=5073.9 FG=5074.51 17+00 EG=5074.9 FG=5073.96 17+50 EG=5074.3 FG=5073.82 18+00 0.63% 1.89% -1.36% -1.81% -1.71% -1.71% -0.50% 0.18% PVI STA = 10+00.00 PVI ELEV = 5076.09 PVI STA = 17+53.67 PVI ELEV = 5073.84 PVI STA = 10+49.77 PVI ELEV = 5075.24 PVI STA = 11+02.62 PVI ELEV = 5074.34 PVI STA = 17+67.77 PVI ELEV = 5073.77 PVI STA = 18+06.92 PVI ELEV = 5073.84 105.4' VC HIGH PT EL: 5074.53 HIGH PT STA: 16+89.47 PVI STA: 16+88.33 PVI EL: 5075.02 AD: 3.70 K: 28.49 BVCS: 16+35.62 BVCE: 5074.02 EVCS: 17+41.05 EVCE: 5074.06 73.3' VC LOW PT EL: 5071.08 LOW PT STA: 13+67.38 PVI STA: 13+53.91 PVI EL: 5070.92 AD: 1.99 K: 36.83 BCVS: 13+17.25 BVCE: 5071.42 ECVS: 13+90.57 EVCE: 5071.15 68.2' VC PVI STA: 15+30.22 PVI EL: 5072.03 AD: 1.26 K: 54.09 BCVS: 14+96.13 BVCE: 5071.82 ECVS: 15+64.31 EVCE: 5072.67 PROPOSED GRADE EXISTING GROUND STA: 13+64.10 INV.= 5067.24' PROP. 18" STORM UPSTREAM PAN CURB RETURN HORNET DRIVE_FL(RIGHT) PROFILE 5065 5070 5075 5080 5085 5090 5065 5070 5075 5080 5085 5090 EG=5076.5 FG=5075.22 10+50 EG=5074.5 FG=5074.39 11+00 EG=5074.2 FG=5073.80 11+50 EG=5073.5 FG=5073.22 12+00 EG=5072.1 FG=5072.65 12+50 EG=5072.9 FG=5072.07 13+00 EG=5072.4 FG=5071.49 13+50 EG=5071.9 FG=5071.08 14+00 EG=5070.9 FG=5071.21 14+50 EG=5071.8 FG=5071.49 15+00 EG=5071.6 FG=5071.78 15+50 EG=5072.1 FG=5072.20 16+00 EG=5071.9 FG=5072.94 16+50 EG=5072.3 FG=5073.75 17+00 EG=5073.6 FG=5074.44 17+50 EG=5074.6 FG=5074.47 18+00 EG=5074.6 FG=5073.81 18+50 EG=5073.5 FG=5073.34 19+00 0.57% 1.63% -1.16% -1.68% -1.65% -1.65% -0.70% PVI STA = 10+00.01 PVI ELEV = 5076.05 PVI STA = 18+61.78 PVI ELEV = 5073.61 PVI STA = 10+49.79 PVI ELEV = 5075.22 PVI STA = 11+03.36 PVI ELEV = 5074.34 PVI STA = 19+01.17 PVI ELEV = 5073.34 114.6' VC HIGH PT EL: 5074.55 HIGH PT STA: 17+77.11 PVI STA: 17+78.03 PVI EL: 5075.02 AD: 3.31 K: 34.64 BVCS: 17+20.74 BVCE: 5074.09 EVCS: 18+35.31 EVCE: 5074.06 76.7' VC LOW PT EL: 5071.06 LOW PT STA: 14+12.29 PVI STA: 13+99.26 PVI EL: 5070.92 AD: 1.73 K: 44.45 BCVS: 13+60.92 BVCE: 5071.36 ECVS: 14+37.60 EVCE: 5071.14 81.8' VC PVI STA: 15+94.26 PVI EL: 5072.03 AD: 1.06 K: 77.35 BCVS: 15+53.35 BVCE: 5071.80 ECVS: 16+35.17 EVCE: 5072.69 STA: 14+11.14 INV.= 5067.09' PROP. 18" STORM PROPOSED GRADE EXISTING GROUND RIGHT-OF-WAY PROPOSED CURB & GUTTER S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP CENTERLINE 0 50' 100' SCALE: 1" = 50' 25' HORNET DRIVE STREET PLAN C700 5' CHECKED BY: 50' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 11+00 10+00 9+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 19+75 STA: 9+00.00 N: 1421901.49 E: 3112382.34 BEGIN ALIGNMENT STA: 19+74.88 N: 1421871.87 E: 3112823.41 END ALIGNMENT 1ƒ ( ¨ = 9 0 ƒ 1 2 ' 1 4 " L = 2 5 9. 7 7 , R = 1 6 5 . 0 0 6ƒ ( ¨ = 89 ƒ 4 7 ' 4 6 " L = 2 5 8 . 5 9, R = 1 6 5 . 0 0 6ƒ ( STA: 10+48.12 BEGIN CONSTRUCTION MATCH EXISTING BON HOMME RICHARD DRIVE N: 1421753.37 E: 3112382.34 STA: 18+80.08 END CONSTRUCTION MATCH EXISTING BON HOMME RICHARD DRIVE N: 1421777.07 E: 3112823.41 27.67' EP-EP NIMITZ DRIVE ENTERPRISE DRIVE 53' ROW HORNET DRIVE CABOT COURT 68' ROW 30' EXCLUSIVE S. FT. COLLINS SANITARY SEWER EASEMENT REC. NO. 99055752 BLOCK 4 BLOCK 5 BLOCK 6 BLOCK 7 BLOCK 8 BLOCK 9 BLOCK 10 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 10 LOT 9 LOT 8 OUTLOT C LOT 7 LOT 6 LOT 5 LOT 4 LOT 3 LOT 4 LOT 1 LOT 2 LOT 3 LOT 2 LOT 1 LOT 1 LOT 2 LOT 3 LOT 4 TRACT C LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 1 TRACT D LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 (PRIVATE DRIVE) CABOT COURT (PRIVATE DRIVE) 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 CENTERLINE NOT TO SCALE 4.5' SW 31" DRIVE-OVER CURB AND GUTTER HORNET DRIVE TYPICAL STREET SECTION 7' PKWY 4.5' SW 7' PKWY 53' ROW 30' FL-FL 2% MIN. 2% MIN. 2% MIN. 2% MIN. 7' PKG 16' DRIVE LANE 7' PKG 13.83' EP-EP 13.83' EP-EP 1. SPOT ELEVATIONS ON THE ROAD ARE TO FINISHED SURFACE. CONSULT THE SOILS REPORT FOR PAVEMENT SECTION. 2. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE FIELD CONDITIONS ARE AS SHOWN IN THE DRAWINGS. IF THE CONTRACTOR FINDS DISCREPANCIES THE CONTRACTOR SHALL CONTACT THE ENGINEER. 3. TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FORM THE 100-YEAR STORM. 4. THE CONTRACTOR SHALL REFER TO SHEETS C700-C701 FOR FINAL ROAD LAYOUT AND PLAN AND PROFILES. 5. THE CONTRACTOR SHALL REFER TO SHEETS C702-C703 FOR INTERSECTION GRADING DETAILS. 5. THE CONTRACTOR SHALL REFER TO SHEETS C500-C501 FOR STORM SEWER PLAN AND PROFILES. 6. ALL DISTURBED AREAS NOT PAVED SHALL BE REVEGETATED PER THE LANDSCAPE PLANS PLOT PLAN MAY REQUIRE ADDITIONAL STEPS AT DOOR OR GARAGE FOR T.F. SHOWN * NIMITZ DRIVE HORNET DRIVE CABOT COURT POROUS LANDSCAPE DETENTION POROUS LANDSCAPE DETENTION ENTERPRISE DR. 26' ACCESS, EMERGENCY ACCESS, UTILITY& DRAINAGE EASEMENT 20' ACCESS, UTILITY & DRAINAGE EASEMENT 53' ROW 68' ROW 30' EXCLUSIVE S. FT. COLLINS SANITARY SEWER EASEMENT 22.86' UTILITY, DRAINAGE GRADING & LANDSCAPE EASEMENT KITTY HAWK COURT BLOCK 4 BLOCK 4 BLOCK 4 BLOCK 5 BLOCK 6 BLOCK 7 BLOCK 8 BLOCK 9 BLOCK 10 OUTLOT B OUTLOT C TRACT C TRACT D PERMEABLE PAVERS 6" UNDER DRAIN 18" STORM DRAIN CURB CUT & SIDEWALK CHASE CURB CUT & SIDEWALK CHASE POND OVERFLOW STRUCTURE GRATE = 5064.10 24" STORM DRAIN CITY HIGH RISK FLOODWAY (PRIVATE DRIVE) (PRIVATE DRIVE) CABOT COURT (PRIVATE DRIVE) TOP OF POND = 5065.10 DUAL 24"x72" RCP BOX CULVERTS MATCH EXISTING SWALE PROTECT EXISTING TREE PROTECT EXISTING TREE PROTECT EXISTING TREE CONNECT TO EXISTING SIDEWALK 1. SPOT ELEVATIONS ON THE ROAD ARE TO FINISHED SURFACE. CONSULT THE SOILS REPORT FOR PAVEMENT SECTION. 2. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE FIELD CONDITIONS ARE AS SHOWN IN THE DRAWINGS. IF THE CONTRACTOR FINDS DISCREPANCIES THE CONTRACTOR SHALL CONTACT THE ENGINEER. 3. TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FORM THE 100-YEAR STORM. 4. THE CONTRACTOR SHALL REFER TO SHEETS C700-C701 FOR FINAL ROAD LAYOUT AND PLAN AND PROFILES. 5. THE CONTRACTOR SHALL REFER TO SHEETS C702-C703 FOR INTERSECTION GRADING DETAILS. 5. THE CONTRACTOR SHALL REFER TO SHEETS C500-C501 FOR STORM SEWER PLAN AND PROFILES. 6. ALL DISTURBED AREAS NOT PAVED SHALL BE REVEGETATED PER THE LANDSCAPE PLANS * PLOT PLAN MAY REQUIRE ADDITIONAL STEPS AT DOOR OR GARAGE FOR T.F. SHOWN NIMITZ DRIVE CABOT COURT ENTERPRISE DR. 26' ACCESS, EMERGENCY ACCESS, UTILITY& DRAINAGE EASEMENT 20' ACCESS, UTILITY & DRAINAGE EASEMENT 68' ROW 30' EXCLUSIVE S. FT. COLLINS SANITARY SEWER EASEMENT 22.86' UTILITY, DRAINAGE GRADING & LANDSCAPE EASEMENT 30' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT 26' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT KITTY HAWK COURT BLOCK 1 BLOCK 2 BLOCK 3 BLOCK 4 BLOCK 4 BLOCK 4 BLOCK 5 BLOCK 9 OUTLOT A TRACT A TRACT B OUTLOT B TRACT C TRACT D PERMEABLE PAVERS 2' SIDEWALK CHASE 12" STORM DRAIN 12" STORM DRAIN 2' SIDEWALK CHASE (PRIVATE DRIVE) KITTY HAWK COURT (PRIVATE DRIVE) SAIPAN COURT (PRIVATE DRIVE) (PRIVATE DRIVE) CABOT COURT (PRIVATE DRIVE) LIMITS OF DISTURBANCE TO BE DETERMINED BY CONTRACTOR SLOPE PROTECTION (SEE EROSION CONTROL NOTE 5) DROP INLET PROTECTION EROSION CONTROL BLANKET (SEE NOTE 6) POROUS LANDSCAPE DETENTION ROCK SOCK S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP CONSTRUCTION FENCE TEMPORARY SEDIMENT BASIN EROSION CONTROL SEQUENCING EROSION CONTROL NOTES 0 40' 80' SCALE: 1" = 40' 20' 1. THE SITE WILL BE LANDSCAPED TO FINAL STABILIZATION. SEE FINAL LANDSCAPE PLAN FOR DETAILS. 2. REFER TO SHEET C001 FOR STANDARD EROSION AND SEDIMENT CONTROL CONSTRUCTION PLAN NOTES. 3. EROSION CONTROL PRACTICES, SITE PROTECTION, AND REVEGETATION METHODS SHALL FOLLOW CITY REGULATIONS. 4. IN ADDITION TO THE EROSION CONTROL MEASURES SHOWN ON THIS DRAWING, THE CONTRACTOR SHALL COORDINATE WITH, AND UPDATE AS REQUIRED, THE STORMWATER MANAGEMENT PLAN (SWMP) FOR THIS PROJECT. 5. CONTRACTOR TO TERRACE SLOPES USING A "TRACKED" VEHICLE, RUN PERPENDICULAR TO SLOPE TO INHIBIT RILL/GULLEY EROSION, CONTRACTOR MAY USE OTHER WINDROW-TYPE METHODS AS APPROVED BY ENGINEER. TYPICAL ALL SLOPES, REPEAT AS NECESSARY UNTIL LANDSCAPING IS INSTALLED. 6. ANY AREAS USED FOR STOCKPILING AND/OR STAGING SHOULD ALSO HAVE SEDIMENT AND EROSION CONTROL MEASURES AS NECESSARY. THESE AREAS SHOULD BE LOCATED AT LEAST 100' AWAY FROM DRAINAGE WAYS. THE SWMP SHOULD BE UPDATED TO SHOW THESE AREAS AND SEDIMENT AND EROSION CONTROL ITEMS. THE ITEMS MAY INCLUDE BUT ARE NOT LIMITED TO VEHICLE TRACKING CONTROL, SILT FENCE, CONSTRUCTION FENCE, CONCRETE WASHOUT, AND SEDIMENT TRAP. 7. SOIL AMENDMENTS SHALL BE INCORPORATED IN ALL LANDSCAPE AREAS TO A DEPTH OF 6" AT A RATE OF 3 CUBIC YARDS PER 1000 SQUARE FEET OF AREA -OR- 4" OF LOOSE TOPSOIL IMPORTED ONTO THE SITE OVER 4" OF LOOSENED SUBGRADE SOILS. REFER TO CITY OF FORT COLLINS CODE SECTIONS 12-130 THROUGH 12-132. 8. TEMPORARY SEEDING SHALL BE UTILIZED IN THE EVENT THAT A GRADED AREA IS EXPOSED LONGER THAN 30 DAYS. THE SITE SHALL BE SEEDED WITH 100% SMOOTH BROME AT A MINIMUM APPLICATION RATE OF 30 PLS/LBS/ACRE. 9. A COMMERCIAL FERTILIZER WITH THE FOLLOWING SPECS SHALL BE USED: PROJECT: BEST MANAGEMENT PRACTICE ITEM: PRESERVE EXISTING VEGETATION SILT FENCE VEHICLE TRACKING CONTROL STAGING AREAS CONCRETE WASHOUT AREA CURB INLET PROTECTION (RS) SWALE AND SLOPE PROTECTION SIDEWALK CHASE FILTER PHASE OF CONSTRUCTION 26' ACCESS, EMERGENCY ACCESS, UTILITY& DRAINAGE EASEMENT 20' ACCESS, UTILITY & DRAINAGE EASEMENT 53' ROW 68' ROW 30' EXCLUSIVE S. FT. COLLINS SANITARY SEWER EASEMENT PERMEABLE PAVERS 6" UNDER DRAIN 18" STORM DRAIN CURB CUT & SIDEWALK CHASE CURB CUT & SIDEWALK CHASE POND OVERFLOW STRUCTURE 24" STORM DRAIN CITY HIGH RISK FLOODWAY 2' SIDEWALK CHASE BLOCK 4 BLOCK 4 BLOCK 4 BLOCK 5 BLOCK 6 BLOCK 7 BLOCK 8 BLOCK 9 BLOCK 10 TRACT B LOT 14 LOT 13 OUTLOT B LOT 1 LOT 2 LOT 1 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 10 LOT 9 LOT 8 OUTLOT C LOT 7 LOT 6 LOT 5 LOT 4 LOT 2 LOT 3 LOT 1 LOT 4 LOT 3 LOT 2 LOT 1 LOT 4 LOT 2 LOT 3 LOT 1 TRACT C LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 6 LOT 7 LOT 8 LOT 5 LOT 1 LOT 2 LOT 3 LOT 4 TRACT D LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 NIMITZ DRIVE HORNET DRIVE CABOT COURT POROUS LANDSCAPE DETENTION POROUS LANDSCAPE DETENTION ENTERPRISE DR. KITTY HAWK COURT (PRIVATE DRIVE) KITTY HAWK COURT (PRIVATE DRIVE) (PRIVATE DRIVE) CABOT COURT (PRIVATE DRIVE) 22.86' UTILITY, DRAINAGE GRADING & LANDSCAPE EASEMENT CONCRETE WASHOUT AREA - FINAL LOCATION TO BE DETERMINED BY CONTRACTOR SLOPE PROTECTION (SEE EROSION CONTROL NOTE 5) DROP INLET PROTECTION EROSION CONTROL BLANKET (SEE NOTE 6) POROUS LANDSCAPE DETENTION ROCK SOCK S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP CONSTRUCTION FENCE TEMPORARY SEDIMENT BASIN PROJECT: BEST MANAGEMENT PRACTICE ITEM: PRESERVE EXISTING VEGETATION SILT FENCE VEHICLE TRACKING CONTROL STAGING AREAS CONCRETE WASHOUT AREA CURB INLET PROTECTION (RS) SWALE AND SLOPE PROTECTION SIDEWALK CHASE FILTER PHASE OF CONSTRUCTION EROSION CONTROL SEQUENCING EROSION CONTROL NOTES 1. THE SITE WILL BE LANDSCAPED TO FINAL STABILIZATION. SEE FINAL LANDSCAPE PLAN FOR DETAILS. 2. REFER TO SHEET C001 FOR STANDARD EROSION AND SEDIMENT CONTROL CONSTRUCTION PLAN NOTES. 3. EROSION CONTROL PRACTICES, SITE PROTECTION, AND REVEGETATION METHODS SHALL FOLLOW CITY REGULATIONS. 4. IN ADDITION TO THE EROSION CONTROL MEASURES SHOWN ON THIS DRAWING, THE CONTRACTOR SHALL COORDINATE WITH, AND UPDATE AS REQUIRED, THE STORMWATER MANAGEMENT PLAN (SWMP) FOR THIS PROJECT. 5. CONTRACTOR TO TERRACE SLOPES USING A "TRACKED" VEHICLE, RUN PERPENDICULAR TO SLOPE TO INHIBIT RILL/GULLEY EROSION, CONTRACTOR MAY USE OTHER WINDROW-TYPE METHODS AS APPROVED BY ENGINEER. TYPICAL ALL SLOPES, REPEAT AS NECESSARY UNTIL LANDSCAPING IS INSTALLED. 6. ANY AREAS USED FOR STOCKPILING AND/OR STAGING SHOULD ALSO HAVE SEDIMENT AND EROSION CONTROL MEASURES AS NECESSARY. THESE AREAS SHOULD BE LOCATED AT LEAST 100' AWAY FROM DRAINAGE WAYS. THE SWMP SHOULD BE UPDATED TO SHOW THESE AREAS AND SEDIMENT AND EROSION CONTROL ITEMS. THE ITEMS MAY INCLUDE BUT ARE NOT LIMITED TO VEHICLE TRACKING CONTROL, SILT FENCE, CONSTRUCTION FENCE, CONCRETE WASHOUT, AND SEDIMENT TRAP. 7. SOIL AMENDMENTS SHALL BE INCORPORATED IN ALL LANDSCAPE AREAS TO A DEPTH OF 6" AT A RATE OF 3 CUBIC YARDS PER 1000 SQUARE FEET OF AREA -OR- 4" OF LOOSE TOPSOIL IMPORTED ONTO THE SITE OVER 4" OF LOOSENED SUBGRADE SOILS. REFER TO CITY OF FORT COLLINS CODE SECTIONS 12-130 THROUGH 12-132. 8. TEMPORARY SEEDING SHALL BE UTILIZED IN THE EVENT THAT A GRADED AREA IS EXPOSED LONGER THAN 30 DAYS. THE SITE SHALL BE SEEDED WITH 100% SMOOTH BROME AT A MINIMUM APPLICATION RATE OF 30 PLS/LBS/ACRE. 9. A COMMERCIAL FERTILIZER WITH THE FOLLOWING SPECS SHALL BE USED: 26' ACCESS, EMERGENCY 68' ROW 30' EXCLUSIVE S. FT. COLLINS SANITARY SEWER EASEMENT 26' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT 2' SIDEWALK CHASE 12" STORM DRAIN 12" STORM DRAIN 2' SIDEWALK CHASE BLOCK 1 BLOCK 2 BLOCK 3 BLOCK 4 BLOCK 4 BLOCK 4 BLOCK 5 BLOCK 9 LOT 1 OUTLOT A LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 TRACT A LOT 1 LOT 2 LOT 3 LOT 4 LOT 1 LOT 2 LOT 3 LOT 5 LOT 4 LOT 6 TRACT B LOT 14 LOT 13 OUTLOT B LOT 1 LOT 2 LOT 1 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 10 LOT 9 LOT 5 LOT 6 LOT 7 LOT 8 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 NIMITZ DRIVE TERPRISE DR. KITTY HAWK COURT (PRIVATE DRIVE) KITTY HAWK COURT (PRIVATE DRIVE) SAIPAN COURT (PRIVATE DRIVE) 30' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT LIMITS OF DISTURBANCE 22.86' UTILITY, DRAINAGE GRADING & LANDSCAPE EASEMENT THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE WATER SERVICE SANITARY SERVICE STORM FLARED END MAPPING EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER M.H. SANITARY SEWER M.H. S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP 0 30' 60' SCALE: 1" = 30' 15' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 9+50 10+00 11+00 KITTY HAWK COURT (PRIVATE DRIVE) ENTERPRISE DRIVE BLOCK 3 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 1 STORM LINE 5 PROFILE 5060 5065 5070 5075 5080 5085 5090 5060 5065 5070 5075 5080 5085 5090 9+50 10+00 10+50 11+00 46.32 LF 10" HDPE @ 0.50% EX MH 5 STA. 10+00.00 RIM = 5076.45 INV. IN=5073.07 (SW) INV. OUT=5071.30 (E) INLET 5-1 INV. OUT= 5073.30 (NE) STA: 10+46.32 STA: 10+28.88 INV.= 5065.97 PROP. 8" SANITARY EXISTING GROUND PROPOSED GRADE 100-YR HGL CORE DRILL AND CONNECT TO EXISTING MANHOLE 11+50 9+50 10+00 11+00 TBC EL = 5076.55 N = 1422321.64 E = 3113031.49 TBC EL = 5076.66 N = 1422327.97 E = 3113031.49 SAIPAN COURT (PRIVATE DRIVE) BLOCK 2 BLOCK 1 LOT 4 LOT 3 LOT 5 LOT 6 TRACT A LOT 2 LOT 1 LOT 3 LOT 4 EXISTING 30" STORM SOUTH SHIELDS STREET 5' DRAINAGE EASEMENT STORM LINE 6 PROFILE 5060 5065 5070 5075 5080 5085 5090 5060 5065 5070 5075 5080 5085 5090 9+50 10+00 10+50 11+00 11+50 EXISTING GROUND PROPOSED GRADE INLET 6-1 INV. OUT= 5072.27 (S) STA: 11+28.76 EX MH 6 STA. 10+00.00 RIM = 5074.02 INV. IN=5071.31 (N) INV. OUT=5070.00 (S) 128.76 LF 12" HDPE @ 0.75% 100-YR HGL CORE DRILL AND CONNECT TO EXISTING MANHOLE EXISTING 30" RCP @ 0.20% STORM LINE 4 PROFILE 5050 5055 5060 5065 5070 5075 5080 5050 5055 5060 5065 5070 5075 5080 11+00 10+50 10+00 9+50 HEADWALL 4 STA: 10+00.00 INV. = 5065.22 HEADWALL 4-1 STA: 10+24.00 INV. = 5065.46 EXISTING GROUND 24.00 LF DUAL 24"x 72" RCP BOX CULVERTS @ 1.00% (BY PRECAST CONCEPTS OR APPROVED EQUAL) 100-YR HGL 11+00 9+50 10+00 (PRIVATE DRIVE) SEE SHEET C500 FOR PROFILE BLOCK 7 BLOCK 8 LOT 2 LOT 3 LOT 1 TRACT C LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 CONCRETE HEADWALL (SEE DETAILS) CABOT COURT TYPE L RIPRAP PAD 17' 20' 17' 20' TYPE L RIPRAP PAD THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE WATER SERVICE SANITARY SERVICE STORM FLARED END MAPPING EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER M.H. SANITARY SEWER M.H. S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP 0 30' 60' SCALE: 1" = 30' 15' CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 9+50 10+00 11+00 SEE THIS SHEET FOR PROFILE LOT 3 LOT 2 POROUS LANDSCAPE DETENTION POROUS LANDSCAPE DETENTION INV.5061.1 INV.5060.9 INV.5061.5 4" PERFORATED PVC @ 0.5% 4" PERFORATED PVC @ 0.5% INSTALL 5' WIDE TYPE L RIPRAP PAD TO BOTTOM OF SLOPE STORM LINE 1 PROFILE 5045 5050 5055 5060 5065 5070 5075 5045 5050 5055 5060 5065 5070 5075 9+50 10+00 10+50 11+00 FES 1 STA: 10+00.00 INV. = 5059.00 INLET 1-1 STA. 10+57.91 RIM = 5064.10 INV. IN = 5061.10 (E) INV. IN = 5060.50 (W) INV. OUT=5059.57 (SE) 56.73 LF 24" HDPE @ 1.00% EXISTING GROUND PROPOSED GRADE 100-YR HGL 12" MAX. PONDING 9+50 10+00 11+00 11+98 SEE THIS SHEET FOR PROFILE TBC EL = 5071.46 N = 1421482.65 E = 3112573.58 TBC EL = 5071.46 N = 1421482.62 E = 3112579.91 TBC EL = 5071.48 N = 1421515.49 E = 3112571.20 TBC EL = 5071.47 N = 1421515.45 E = 3112582.54 HORNET DRIVE BLOCK 9 BLOCK 12 LOT 3 LOT 2 LOT 1 LOT 4 LOT 3 LOT 2 LOT 7 LOT 6 LOT 5 LOT 4 LOT 3 LOT 2 LOT 1 POROUS LANDSCAPE DETENTION POROUS LANDSCAPE DETENTION 5' X 5' TYPE L RIPRAP PAD STORM LINE 2 PROFILE 5050 5055 5060 5065 5070 5075 5080 5050 5055 5060 5065 5070 5075 5080 9+50 10+00 10+50 11+00 11+50 12+00 12+50 EXISTING GROUND PROPOSED GRADE FES 2 STA: 10+00.00 INV. = 5063.37 MH 2-1 (FLAT TOP) STA. 10+25.11 RIM = 5067.78 INV. IN=5063.50 (N) INV. OUT=5063.50 (SE) 25.11 LF 24" RCP @ 0.50% 128.95 LF 24" RCP @ 0.50% INLET 2-2 INV. IN= 5067.07 (N) INV. OUT= 5064.14 (S) STA: 11+54.06 INLET 2-3 INV. OUT= 5067.25 (S) STA: 11+89.96 STA: 11+63.14 TOP = 5065.28 (TO BE DEFLECTED UNDER STORM) PROP. 8" WATER 100-YR HGL 18" MIN. 35.90 LF 18" RCP @ 0.50% CONCRETE ENCASE STORM SEWER 10' ON EITHER SIDE OF CROSSING STORM LINE 3 PROFILE 5050 5055 5060 5065 5070 5075 5080 5050 5055 5060 5065 5070 5075 5080 9+50 10+00 10+50 11+00 FES 3 STA: 10+00.00 INV. = 5065.91 INLET 3-1 INV. OUT= 5066.01 (S) STA: 10+21.49 INV. IN = 5066.75 (N) 21.49 LF 18" RCP @ 0.50% EXISTING GROUND PROPOSED GRADE 100-YR HGL 9+50 10+00 11+00 TBC EL = 5069.49 N = 1421557.49 E = 3112102.57 TBC EL = 5069.57 N = 1421557.47 SEE SHEET C501 E = 3112108.90 FOR PROFILE CABOT COURT (PRIVATE DRIVE) BLOCK 7 BLOCK 8 LOT 3 LOT 2 LOT 1 TRACT C LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 UNDERDRAIN FOR PAVERS (SEE DETAILS) TYPE L RIPRAP PAD 17' 20' PROPOSED UTILITIES 8" WATER LINE WATER SERVICE SANITARY SERVICE MAPPING EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER M.H. STORM SEWER M.H. S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP STORM DRAIN INLET STORM END SECTION STREET LIGHT CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 5055 5060 5065 5070 5075 5080 5085 5055 5060 5065 5070 5075 5080 5085 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 MH C6 STA 10+00.00 5,0“ INV. IN 5060.19 (W) INV. IN 5060.99 (E) INV. OUT 5059.99 (S) D = 14.48' MH C6.1(W) STA 6+85.00 5,0“ INV. OUT 5061.61 (E) D = 10.18' 315.00 LF 8" PVC @ 0.45% PROPOSED GRADE EXISTING GROUND STA: 9+89.00 INV.= 5069.51' 8" WATER 375.00 LF 8" PVC @ 0.75% MH C6.1(E) STA 13+75.00 5,0“ INV. OUT 5063.80 (W) D = 11.22' 14+00 6+50 7+00 8+00 9+00 10+00 11+00 12+00 13+00 SEE SHEET C401 FOR PROFILE ƒ STA:6+50.00 N=1421651.21 E=3112039.35 BEGIN SANITARY SEWER ALIGNMENT STA:14+00.00 N=1421650.05 E=3112789.34 END SANITARY SEWER ALIGNMENT 26' ACCESS, UTILITY & DRAINAGE EASEMENT CABOT COURT (PRIVATE DRIVE) CABOT COURT (PRIVATE DRIVE) 20' ACCESS, UTILITY & DRAINAGE EASEMENT ENTERPRISE DRIVE BLOCK 5 BLOCK 6 BLOCK 9 BLOCK 10 LOT 1 LOT 2 LOT 3 LOT 4 TRACT C LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 TRACT D LOT 7 LOT 8 LOT 9 LOT 10 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 4' UTILITY EASEMENT 8' UTILITY & PEDESTRIAN ACCESS EASEMENT 5' UTILITY EASEMENT 5' UTILITY EASEMENT NIMITZ DRIVE PROPOSED UTILITIES 8" WATER LINE WATER SERVICE SANITARY SERVICE MAPPING EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER M.H. STORM SEWER M.H. S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP STORM DRAIN INLET STORM END SECTION STREET LIGHT CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 9+50 10+00 11+00 12+00 13+00 14+00 15+00 15+50 ƒ ƒ ƒ ƒ ƒ ƒ SEE SHEET C402 FOR PROFILE STA:9+50.00 N=1421211.51 E=3112620.49 BEGIN SANITARY SEWER ALIGNMENT STA:15+50.00 N=1421690.33 E=3112389.64 END SANITARY SEWER ALIGNMENT NIMITZ DRIVE HORNET DRIVE 30' UTILITY & DRAINAGE EASMENT 10' 13 7 53' ROW SEE SHEET C402 FOR PROFILE EXISTING 8" SANITARY CABOT COURT BLOCK 4 BLOCK 7 BLOCK 9 BLOCK 10 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 4 LOT 1 LOT 2 LOT 3 LOT 2 LOT 1 LOT 4 LOT 8 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 TRACT D LOT 7 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 (PRIVATE DRIVE) 5' UTILITY EASEMENT 5' UTILITY EASEMENT 20' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT 5055 5060 5065 5070 5075 5080 5085 5055 5060 5065 5070 5075 5080 5085 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 MH C6 STA 15+09.72 5,0“ INV. IN 5060.19 (W) INV. IN 5060.99 (E) INV. OUT 5059.99 (S) D = 14.48' 8" PVC 24.41 LF @ 0.45% MH C5 STA 14+85.30 5,0“ INV. IN 5059.88 (N) INV. OUT 5059.68 (SE) D = 14.55' 87.18 LF 8" PVC @ 0.45% MH C4 STA 13+98.12 5,0“ INV. IN 5059.29 (NW) INV. OUT 5059.09 (SE) D = 14.03' 63.47 LF 8" PVC @ 0.45% MH C3 STA 13+34.65 5,0“ INV. IN 5058.81 (NW) INV. OUT 5058.61 (E) D = 13.71' 80.41 LF 8" PVC @ 0.45% MH C2 STA 12+54.25 5,0“ INV. IN 5058.24 (W) INV. OUT 5058.04 (S) D = 13.42' 190.25 LF 8" PVC @ 0.45% MH C1 STA 10+64.00 5,0“ INV. IN 5057.19 (N) INV. OUT 5056.99 (SE) D = 8.07' EX MH STA 10+00.00 5,0“ INV. IN 5056.70 (NW) EX. INV. IN 5056.50 (W) EX. INV. OUT 5056.50 (E) D = 5.28' 64.00 LF 8" PVC @ 0.45% PROPOSED GRADE EXISTING GROUND STA: 10+52.08 INV.= 5062.22' 6" UNDER DRAIN STA: 12+44.25 INV.= 5066.26' 8" WATER CORE DRILL AND CONNECT TO EXISTING MANHOLE PROPOSED UTILITIES 8" WATER LINE WATER SERVICE SANITARY SERVICE MAPPING EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER M.H. STORM SEWER M.H. S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP STORM DRAIN INLET STORM END SECTION STREET LIGHT CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: SANITARY SEWER LINE B 9+75 10+00 11+00 12+00 STA: 9+75.00 N: 1422329.70 E: 3112802.41 BEGIN SANITARY SEWER ALIGNMENT STA: 12+00.00 N: 1422329.70 E: 3113027.41 END SANITARY SEWER ALIGNMENT BLOCK 1 BLOCK 2 LOT 1 OUTLOT A LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 TRACT A LOT 1 LOT 2 LOT 3 LOT 4 LOT 1 EXISTING 6" SANITARY SEWER SERVICE EXISTING 6" SANITARY SEWER SERVICE EXISTING 6" SANITARY SEWER SERVICE EXISTING 6" SANITARY SEWER SERVICE SAIPAN COURT (PRIVATE DRIVE) 30' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT 5055 5060 5065 5070 5075 5080 5085 5055 5060 5065 5070 5075 5080 5085 9+75 10+00 10+50 11+00 11+50 12+00 EX MH STA 10+00.00 5,0“ INV. IN 5064.60 (E) EX INV. IN 5062.70 (N) EX INV. OUT 5062.60 (S) D = 13.98' 181.57 LF 8" PVC @ 1.00% MH A1 STA 11+81.57 5,0“ INV. OUT 5066.42 (W) D = 10.41' PROPOSED GRADE EXISTING GROUND CORE DRILL AND CONNECT TO EXISTING MANHOLE CONSTRUCT NEW INVERT CHANNEL FROM CONNECTION TO EXISTING CHANNEL 5055 5060 5065 5070 5075 5080 5085 5055 5060 5065 5070 5075 5080 5085 9+75 10+00 10+50 11+00 EX MH STA 10+00.00 5,0“ INV. IN 5065.00 (SE) EX INV. IN 5064.10 (E) EX. INV. IN 5064.00 (SW) EX INV. OUT 5064.00 (N) D = 13.60' 82.00 LF 8" PVC @ 1.00% MH B1 STA 10+82.00 5,0“ INV. OUT 5065.82 (NW) D = 11.53' STA: 10+22.99 INV.= 5073.21' PROP. 12" STORM DRAIN PROPOSED GRADE EXISTING GROUND CORE DRILL AND CONNECT TO EXISTING MANHOLE. GROUT FILL THE EXISTING 6" INVERT TO THE EAST CONSTRUCT NEW INVERT CHANNEL FROM CONNECTION TO EXISTING CHANNEL. 9+75 10+00 11+00 STA: 9+75.00 N: 1422217.83 E: 3112610.56 BEGIN SANITARY SEWER ALIGNMENT STA: 11+00.00 N: 1422117.55 E: 3112685.17 END SANITARY SEWER ALIGNMENT BLOCK 3 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 TRACT B OUTLOT B (PRIVATE DRIVE) KITTY HAWK COURT 26' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT VINSON STREET KEYMAP LOT LINES EASEMENT LINES RIGHT-OF-WAY STORM DRAIN M.H. NOTES 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. WATER SERVICE PROVIDED BY FORT COLLINS-LOVELAND WATER DISTRICT. SANITARY SERVICE PROVIDED BY SOUTH FORT COLLINS SANITATION DISTRICT. SEE THE CONSTRUCTION SPECIFICATIONS. 3. THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING ELEVATIONS OF ALL EXISTING SEWER MAINS, WATER MAINS, CURBS, GUTTERS AND OTHER UTILITIES AT THE POINTS OF CONNECTION SHOWN ON THE PLANS, AND AT ANY UTILITY CROSSINGS PRIOR TO INSTALLING ANY OF THE NEW IMPROVEMENTS. IF A CONFLICT EXISTS AND/OR A DESIGN MODIFICATION IS REQUIRED, THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE IN PAVED AREAS. 4. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 5.0'. MAXIMUM COVER SHALL BE 6.0'. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 6. ALL WATER SERVICES REQUIRE METER PIT INSTALLATION. METER PITS SHALL BE LOCATED ONE FOOT INSIDE THE UTILITY EASEMENT FROM THE PROPERTY LINE AND LOCATED OUTSIDE OF PROPOSED DRIVEWAYS. 7. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 8. SANITARY SEWER MAINS AND SERVICES SHALL BE SDR-35 PVC. 9. WATER MAINS AND FIRE SERVICES SHALL BE AWWA C-900 PVC. WATER SERVICES SHALL BE 3/4" TYPE K COPPER. 10. SANITARY SERVICES TO EXISTING MAINS SHALL BE MADE WITH INSERTA TEES. 11. PUBLIC STREET LIGHTS TO BE INSTALLED BY CITY OF FORT COLLINS LIGHT & POWER. * * DENOTES END OF EXISTING SERVICE * * * 68' ROW NIMITZ DRIVE FIRE HYDRANT TO BE RELOCATED TO CURB 15' UTILITY, LANDSCAPE & DRAINAGE EASEMENT WATER SERVICE (TYP.) SANITARY SERVICE (TYP.) SANITARY LINE C6 (SEE SHEET C402) 20' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT EXISTING FIRE HYDRANT S. SHIELDS STREET EXISTING 36" STORM 22.86' UTILITY & DRAINAGE EASEMENT 30' EXCLUSIVE S. FT. COLLINS SANITARY SEWER EASMENT REC. NO. 99055752 15' UTILITY, LANDSCAPE & DRAINAGE EASEMENT 15' UTILITY, LANDSCAPE & DRAINAGE EASEMENT EXISTING 8" SANITARY ENTERPRISE DRIVE NIMITZ DRIVE SANITARY LINE C (SEE SHEET C401) 30' UTILITY & DRAINAGE EASEMENT 24" STORM DRAIN (SEE SHEET C500) POROUS LANDSCAPE DETENTION POROUS LANDSCAPE DETENTION 24" STORM DRAIN (SEE SHEET C500) CONNECT TO EXISTING 8" SANITARY SEWER 6" UNDER DRAIN 18" STORM DRAIN (SEE SHEET C500) SANITARY LINE C6 (SEE CHEET C402) 26' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT EXISTING FIRE HYDRANT EXISTING 10" WATER BON HOMME RICHARD DRIVE BON HOMME RICHARD DRIVE BLOCK 4 BLOCK 4 BLOCK 4 BLOCK 5 BLOCK 6 BLOCK 7 BLOCK 8 BLOCK 9 BLOCK 10 TRACT B LOT 14 LOT 13 OUTLOT B LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 10 LOT 9 LOT 8 OUTLOT C LOT 7 LOT 6 LOT 5 LOT 4 LOT 3 LOT 1 LOT 2 LOT 4 LOT 3 LOT 2 LOT 1 LOT 1 LOT 2 LOT 3 LOT 4 TRACT C LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 1 TRACT D LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 (PRIVATE DRIVE) KITTY HAWK COURT 8' UTILITY & PEDESTRIAN ACCESS EASEMENT 4' UTILITY EASEMENT 5' UTILITY EASEMENT 5' UTILITY EASEMENT SANITARY SEWER EASEMENT SHALL BE LANDSCAPED WITH NON-IRRIGATED PLANTING. REFER TO THE LANDSCAPE PLANS FOR DETAILS SANITARY SEWER EASEMENT SHALL BE LANDSCAPED WITH NON-IRRIGATED PLANTING. REFER TO THE LANDSCAPE PLANS FOR DETAILS STREET LIGHT RELOCATED STREET LIGHT (SEE TO SHEET C100) STREET LIGHT STREET LIGHT STREET LIGHT STREET LIGHT STREET LIGHT CONNECT TO EXISTING 8" WATER 8" X 8" TAPPING SLEEVE W/T.B. 8" GATE VALVE (W) N=1422018.45 E=3112817.83 8" X 6" REDUCER 6" GATE VALVE (W) N=1422019.08 E=3112640.12 6ƒ ( F.H. ASSEMBLY N=1422019.12 E=3112627.93 CONNECT TO EXISTING 10" WATER 10" X 8" TAPPING SLEEVE W/T.B. 8" GATE VALVE (S) N=1421771.30 E=3112378.34 REMOVE EXISTING HYDRANT & CONNECT TO EXISTING 8" MAIN WITH 8" WATER N=1421731.34 E=3112816.40 ENTERPRISE DRIVE CABOT COURT (PRIVATE DRIVE) HORNET DRIVE CABOT COURT (PRIVATE DRIVE) 1ƒ ( 16.64' 1ƒ ( 6ƒ ( 37.32' 6ƒ ( 6ƒ ( 6ƒ ( 6ƒ ( 1ƒ ( 1ƒ ( 1ƒ ( 8" X 8" TEE W/T.B. 8" GATE VALVE (W) N=1421640.09 E=3112378.35 ƒ%(1':7% N=1421623.45 E=3112378.34 ƒ%(1':7% N=1421588.97 E=3112392.63 ƒ%(1':7% N=1421541.68 E=3112423.99 ƒ%(1':7% N=1421503.79 E=3112480.27 F.H. ASSEMBLY N=1421480.30 E=3112553.73 8" X 6" SWIVEL TEE W/T.B. 8" GATE VALVE (W) 6" GATE VALVE (S) N=1421490.30 E=3112553.76 6ƒ ( ƒ%(1':7% N=1421489.93 E=3112657.79 ƒ%(1':7% N=1421529.75 E=3112754.91 ƒ%(1':7% N=1421591.24 E=3112816.40 DUAL BOX CULVERTS (SEE SHEET C501) 6ƒ ( 8" X 6" REDUCER 6" GATE VALVE (W) N=1421641.21 E=3112063.02 F.H. ASSEMBLY N=1421641.26 E=3112051.44 STREET LIGHT WATER SERVICE TABLE BLOCK# -LOT# 4-1 4-2 4-3 4-4 4-5 4-6 4-7 4-8 4-9 4-10 4-11 4-12 4-13 4-14 5-1 5-2 5-3 5-4 5-5 5-6 NORTHING 1421976.40 1421946.98 1421883.04 1421849.11 1421848.97 1421848.89 1421848.75 1421848.59 1421848.48 1421848.27 1421848.18 1421848.06 1421967.54 1421977.54 1421661.66 1421661.52 1421661.49 1421661.25 1421661.23 1421660.98 EASTING 3112409.97 3112412.97 3112412.97 3112482.45 3112519.95 3112541.80 3112580.75 3112622.30 3112649.55 3112709.99 3112734.80 3112766.86 3112782.83 3112782.83 3112054.01 3112118.98 3112124.98 3112193.98 3112199.98 3112268.98 WATER SERVICE TABLE BLOCK# -LOT# 5-7 5-8 6-1 6-2 6-3 6-4 7-1 7-2 7-3 7-4 8-1 8-2 8-3 8-4 8-5 8-6 8-7 8-8 8-9 8-10 NORTHING 1421660.96 1421668.40 1421625.28 1421625.10 1421624.92 1421613.62 1421552.64 1421510.96 1421469.56 1421468.33 1421464.53 1421464.51 1421476.40 1421478.21 1421529.22 1421533.46 1421609.03 1421657.44 1421707.44 1421713.44 EASTING 3112274.97 3112347.84 3112184.15 3112236.15 3112286.15 3112354.35 3112381.92 3112419.55 3112503.37 3112509.24 3112630.67 3112636.67 3112726.28 3112732.02 3112805.29 3112809.53 3112850.26 3112857.81 3112857.90 3112857.90 WATER SERVICE TABLE BLOCK# -LOT# 9-1 9-2 9-3 9-4 9-5 9-6 9-7 9-8 9-9 9-10 10-1 10-2 10-3 10-4 10-5 10-6 10-7 10-8 NORTHING 1421665.40 1421764.10 1421763.95 1421763.85 1421763.68 1421763.62 1421763.41 1421763.36 1421763.15 1421664.02 1421550.50 1421537.74 1421533.55 1421533.15 1421533.02 1421532.96 1421541.00 1421549.00 EASTING 3112416.84 3112485.73 3112521.70 3112551.70 3112596.70 3112616.70 3112672.25 3112687.25 3112743.23 3112788.91 3112483.40 3112514.12 3112544.90 3112597.41 3112633.92 3112649.54 3112703.26 3112720.15 BLOCK 8 WATER TO BE DEFLECTED UNDER STORM (SEE SHEET C500) SANITARY SERVICE TABLE BLOCK# -LOT# 4-1 4-2 4-3 4-4 4-5 4-6 4-7 4-8 4-9 4-10 4-11 4-12 4-13 4-14 5-1 5-2 5-3 5-4 5-5 5-6 NORTHING 1421986.40 1421956.98 1421847.46 1421848.83 1421849.07 1421848.87 1421849.20 1421848.85 1421850.49 1421848.25 1421848.08 1421851.73 1421957.54 1421987.54 1421661.66 1421661.55 1421661.41 1421661.28 1421661.15 1421661.03 EASTING 3112409.82 3112412.88 3112436.49 3112472.45 3112509.95 3112557.45 3112565.32 3112632.30 3112660.67 3112694.99 3112744.80 3112752.99 3112782.44 3112782.88 3112077.49 3112109.99 3112147.49 3112184.99 3112222.49 3112253.99 SANITARY SERVICE TABLE BLOCK# -LOT# 5-7 5-8 6-1 6-2 6-3 6-4 7-1 7-2 7-3 7-4 8-1 8-2 8-3 8-4 8-5 8-6 8-7 8-8 8-9 8-10 NORTHING 1421660.88 1421660.77 1421625.32 1421625.16 1421624.96 1421598.65 1421544.79 1421504.73 1421475.12 1421466.39 1421462.52 1421367.19 1421377.40 1421417.24 1421422.28 1421465.61 1421579.54 1421609.55 1421705.45 1421715.45 EASTING 3112297.49 3112327.49 3112174.15 3112219.15 3112274.15 3112358.91 3112387.49 3112427.41 3112483.59 3112521.09 3112586.66 3112678.50 3112754.71 3112823.12 3112831.76 3112895.60 3112951.32 3112954.87 3112954.91 3112954.91 SANITARY SERVICE TABLE BLOCK# -LOT# 9-1 9-2 9-3 9-4 9-5 9-6 9-7 9-8 9-9 9-10 10-1 10-2 10-3 10-4 10-5 10-6 10-7 10-8 NORTHING 1421660.05 1421660.05 1421660.05 1421660.05 1421659.55 1421659.55 1421659.55 1421659.55 1421659.55 1421659.55 1421634.05 1421634.05 1421634.05 1421634.05 1421633.55 1421633.56 1421633.55 1421633.55 EASTING 3112447.95 3112457.95 3112522.97 3112532.97 3112597.97 3112607.97 3112672.86 3112682.86 3112737.95 3112757.95 3112484.85 3112494.85 3112559.85 3112569.85 3112634.85 3112644.85 3112710.27 3112720.27 VINSON STREET KEYMAP LOT LINES EASEMENT LINES RIGHT-OF-WAY STORM DRAIN M.H. 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. WATER SERVICE PROVIDED BY FORT COLLINS-LOVELAND WATER DISTRICT. SANITARY SERVICE PROVIDED BY SOUTH FORT COLLINS SANITATION DISTRICT. SEE THE CONSTRUCTION SPECIFICATIONS. 3. THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING ELEVATIONS OF ALL EXISTING SEWER MAINS, WATER MAINS, CURBS, GUTTERS AND OTHER UTILITIES AT THE POINTS OF CONNECTION SHOWN ON THE PLANS, AND AT ANY UTILITY CROSSINGS PRIOR TO INSTALLING ANY OF THE NEW IMPROVEMENTS. IF A CONFLICT EXISTS AND/OR A DESIGN MODIFICATION IS REQUIRED, THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE IN PAVED AREAS. 4. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 5.0'. MAXIMUM COVER SHALL BE 6.0'. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 6. ALL WATER SERVICES REQUIRE METER PIT INSTALLATION. METER PITS SHALL BE LOCATED ONE FOOT INSIDE THE UTILITY EASEMENT FROM THE PROPERTY LINE AND LOCATED OUTSIDE OF PROPOSED DRIVEWAYS. 7. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 8. SANITARY SEWER MAINS AND SERVICES SHALL BE SDR-35 PVC. 9. WATER MAINS AND FIRE SERVICES SHALL BE AWWA C-900 PVC. WATER SERVICES SHALL BE 3/4" TYPE K COPPER. 10. SANITARY SERVICES TO EXISTING MAINS SHALL BE MADE WITH INSERTA TEES. 11. PUBLIC STREET LIGHTS TO BE INSTALLED BY CITY OF FORT COLLINS LIGHT & POWER. NOTES * * * * * * * * DENOTES END OF EXISTING SERVICE 15' UTILITY, LANDSCAPE & DRAINAGE EASEMENT EXISTING 10" WATER 68' ROW FIRE HYDRANT TO BE RELOCATED TO CURB 15' UTILITY, LANDSCAPE & DRAINAGE EASEMENT 15' UTILITY, LANDSCAPE & DRAINAGE EASEMENT EXISTING FIRE HYDRANT TREET ENTERPRISE DRIVE NIMITZ DRIVE BON HOMME RICHARD DRIVE 12" STORM DRAIN (SEE SHEET C501) 30' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT CONNECT TO EXISTING MH EXISTING 8" SANITARY CONNECT TO EXISTING MH 20' DRAINAGE EASEMENT 30' UTILITY EASEMENT SANITARY LINE B (SEE SHEET C400) 66' ROW EXISTING 8" SANITARY EXISTING 30" STORM DRAIN SANITARY SERVICE (TYP.) 26' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT EXISTING FIRE HYDRANT TO REMAIN 15' UTILITY, LANDSCAPE & DRAINAGE EASEMENT S. SHIELDS STREET BLOCK 1 BLOCK 2 BLOCK 3 BLOCK 4 BLOCK 4 BLOCK 4 BLOCK 5 BLOCK 9 LOT 1 OUTLOT A LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 1 LOT 2 LOT 3 LOT 4 LOT 1 LOT 2 LOT 3 LOT 5 LOT 4 LOT 6 TRACT B LOT 14 LOT 13 OUTLOT B LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 10 LOT 9 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 CONNECT TO EXISTING SANITARY SEWER SERVICE (TYP.) CONNECT TO EXISTING SANITARY SEWER SERVICE (TYP.) SAIPAN COURT (PRIVATE DRIVE) KITTY HAWK COURT STREET LIGHT RELOCATED STREET LIGHT (SEE TO SHEET C100) STREET LIGHT STREET LIGHT RELOCATED STREET LIGHT (SEE SHEET C100) SANITARY LINE A (SEE SHEET C400) 8" X 6" REDUCER 6" GATE VALVE (E) N=1422339.70 E=3113022.01 F.H. ASSEMBLY N=1422339.70 E=3113033.99 1ƒ ( CONNECT TO EXISTING 8" WATER 8" X 8" TAPPING SLEEVE W/T.B. 8" GATE VALVE (E) N=1422339.64 E=3112818.60 CONNECT TO EXISTING 8" WATER 8" X 8" TAPPING SLEEVE W/T.B. 8" GATE VALVE (W) N=1422018.45 E=3112817.83 8" X 6" REDUCER 6" GATE VALVE (W) N=1422019.08 E=3112640.12 6ƒ ( F.H. ASSEMBLY N=1422019.12 E=3112627.93 CONNECT TO EXISTING 10" WATER 10" X 8" TAPPING SLEEVE W/T.B. 8" GATE VALVE (S) N=1421771.30 E=3112378.34 REMOVE EXISTING HYDRANT & CONNECT TO EXISTING 8" MAIN WITH 8" WATER N=1421731.34 E=3112816.40 12" STORM DRAIN (SEE SHEET C501) 1ƒ ( ƒ ( WATER SERVICE TABLE BLOCK# -LOT# 1-1 1-2 1-3 1-4 1-5 1-6 2-1 2-2 2-3 2-4 3-1 3-2 3-3 3-4 3-5 3-6 4-1 4-2 4-3 4-4 NORTHING 1422493.77 1422431.78 1422409.69 1422363.76 1422353.22 1422353.22 1422312.21 1422223.21 1422317.22 1422317.20 1422181.31 1422124.07 1422083.06 1422039.33 1422039.36 1422039.61 1421976.40 1421946.98 1421883.04 1421849.11 EASTING 3112884.64 3112873.72 3112870.05 3112865.56 3112964.48 3113026.49 3112873.04 3112864.33 3112961.48 3113023.62 3112782.83 3112782.83 3112782.83 3112710.52 3112700.52 3112635.51 3112409.97 3112412.97 3112412.97 3112482.45 WATER SERVICE TABLE BLOCK# -LOT# 4-5 4-6 4-7 4-8 4-9 4-10 4-11 4-12 4-13 4-14 8-9 8-10 9-2 9-3 9-4 9-5 9-6 9-7 9-8 9-9 NORTHING 1421848.97 1421848.89 1421848.75 1421848.59 1421848.48 1421848.27 1421848.18 1421848.06 1421967.54 1421977.54 1421707.44 1421713.44 1421764.10 1421763.95 1421763.85 1421763.68 1421763.62 1421763.41 1421763.36 1421763.15 EASTING 3112519.95 3112541.80 3112580.75 3112622.30 3112649.55 3112709.99 3112734.80 3112766.86 3112782.83 3112782.83 3112857.90 3112857.90 3112485.73 3112521.70 3112551.70 3112596.70 3112616.70 3112672.25 3112687.25 3112743.23 (PRIVATE DRIVE) TRACT A BLOCK 8 SANITARY SERVICE TABLE BLOCK# -LOT# 1-1 1-2 1-3 1-4 1-5 1-6 2-1 2-2 2-3 2-4 3-1 3-2 3-3 3-4 3-5 3-6 NORTHING 1422483.98 1422441.62 1422418.12 1422351.38 1422353.22 1422353.22 1422317.21 1422254.07 1422317.22 1422317.22 1422168.61 1422152.40 1422093.06 1422039.25 1422118.44 1422118.50 EASTING 3112882.63 3112875.47 3112876.33 3112870.02 3112974.48 3113008.98 3112883.04 3112868.68 3112971.48 3113008.98 3112693.50 3112693.50 3112782.90 3112733.01 3112679.20 3112663.00 SANITARY SERVICE TABLE BLOCK# -LOT# 4-1 4-2 4-3 4-4 4-5 4-6 4-7 4-8 4-9 4-10 4-11 4-12 4-13 4-14 8-9 8-10 NORTHING 1421986.40 1421956.98 1421847.46 1421848.83 1421849.07 1421848.87 1421849.20 1421848.85 1421850.49 1421848.25 1421848.08 1421851.73 1421957.54 1421987.54 1421705.45 1421715.45 EASTING 3112409.82 3112412.88 3112436.49 3112472.45 3112509.95 3112557.45 3112565.32 3112632.30 3112660.67 3112694.99 3112744.80 3112752.99 3112782.44 3112782.88 3112954.91 3112954.91 WATER SERVICE TABLE BLOCK# -LOT# 1-1 1-2 1-3 1-4 1-5 1-6 2-1 2-2 2-3 2-4 3-1 3-2 3-3 3-4 3-5 3-6 4-1 4-2 4-3 4-4 NORTHING 1422493.77 1422431.78 1422409.69 1422363.76 1422353.22 1422353.22 1422312.21 1422223.21 1422317.22 1422317.20 1422181.31 1422124.07 1422083.06 1422039.33 1422039.36 1422039.61 1421976.40 1421946.98 1421883.04 1421849.11 EASTING 3112884.64 3112873.72 3112870.05 3112865.56 3112964.48 3113026.49 3112873.04 3112864.33 3112961.48 3113023.62 3112782.83 3112782.83 3112782.83 3112710.52 3112700.52 3112635.51 3112409.97 3112412.97 3112412.97 3112482.45 WATER SERVICE TABLE BLOCK# -LOT# 4-5 4-6 4-7 4-8 4-9 4-10 4-11 4-12 4-13 4-14 8-9 8-10 9-2 9-3 9-4 9-5 9-6 9-7 9-8 9-9 NORTHING 1421848.97 1421848.89 1421848.75 1421848.59 1421848.48 1421848.27 1421848.18 1421848.06 1421967.54 1421977.54 1421707.44 1421713.44 1421764.10 1421763.95 1421763.85 1421763.68 1421763.62 1421763.41 1421763.36 1421763.15 EASTING 3112519.95 3112541.80 3112580.75 3112622.30 3112649.55 3112709.99 3112734.80 3112766.86 3112782.83 3112782.83 3112857.90 3112857.90 3112485.73 3112521.70 3112551.70 3112596.70 3112616.70 3112672.25 3112687.25 3112743.23 AND PORTION OF BON HOMME RICHARD DRIVE SHALL BE COMPLETED ONCE ALL STREET CUTS FOR UTILITY AND CURB AND GUTTER CONSTRUCTION ARE COMPLETE. 8. BON HOMME RICHARD DRIVE SHALL BE RECONSTRUCTED ONCE ALL STREET CUTS FOR UTILITY CONSTRUCTION ARE COMPLETE. LOT LINES EASEMENT LINES PROPERTY LINE LEGEND NOTES CONCRETE PAVEMENT OR SIDEWALK ASPHALT PAVEMENT CURB & GUTTER CURB & GUTTER T TRANSITION PERMEABLE PAVERS S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP 2" MILL & OVERLAY SAWCUT STREET RECONSTRUCTION RIGHT-OF-WAY CENTERLINE SWALE FLOWLINE LIMITS OF DISTURBANCE 9. SEE SHEET C200 FOR LINE AND CURVE INFORMATION. 68' ROW 53' ROW 15' UTILITY, DRAINAGE, GRADING AND LANDSCAPE EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 2' SIDEWALK CHASE TYPE I DRIVEWAY APPROACH DRIVE OVER CURB & GUTTER 4.5' SIDEWALK 30' EXCLUSIVE S. FT. COLLINS SANITARY SEWER DISTRICT EASEMENT 22.86' UTILITY & DRAINAGE EASEMENT PROPERTY BOUNDARY (TYP.) 30' EXCLUSIVE S. FT. COLLINS SANITARY SEWER DISTRICT EASEMENT 30' UTILITY & DRAINAGE EASEMENT POND OUTLET STUCTURE STORM INLET STORM INLET 27.67' EP-EP DRIVE OVER CURB & GUTTER RIBBON CURB 16.92' EP-EP 2' SIDEWALK CHASE TYPE I DRIVEWAY APPROACH TYPE I DRIVEWAY APPROACH RIBBON CURB 26' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT 8' UTILITY & ACCESS EASEMENT R=25' BOC R=25' BOC PERMEABLE PAVERS DRIVE OVER CURB & GUTTER STORM INLET NIMITZ DRIVE HORNET DRIVE ENTERPRISE DRIVE S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE POROUS LANDSCAPE DETENTION POROUS LANDSCAPE DETENTION CITY HIGH RISK FLOODWAY BLOCK 4 BLOCK 4 BLOCK 4 BLOCK 5 BLOCK 6 BLOCK 7 BLOCK 8 BLOCK 9 BLOCK 10 TRACT B LOT 14 LOT 13 OUTLOT B LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 10 LOT 9 LOT 8 OUTLOT C LOT 7 LOT 6 LOT 5 LOT 4 LOT 3 LOT 4 LOT 1 LOT 2 LOT 3 LOT 2 LOT 1 LOT 1 LOT 2 LOT 3 LOT 4 TRACT C LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 1 TRACT D LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 (PRIVATE DRIVE) KITTY HAWK COURT KITTY HAWK COURT (PRIVATE DRIVE) 4' SIDEWALK 2" MILL & OVERLAY (SEE NOTE 7) 2" MILL & OVERLAY (SEE NOTE 7) (PRIVATE DRIVE) CABOT COURT 4.5' SIDEWALK 4' UTILITY EASEMENT 5' UTILITY EASEMENT (PRIVATE DRIVE) CABOT COURT 5' UTILITY EASEMENT PROPERTY CORNER N:1422008.00 E:3112410.19 PROPERTY CORNER N:1421749.36 E:3112046.60 PROPERTY CORNER N:1421510.85 E:3113053.41 T 8' CONCRETE TRAIL C13 L28 C14 L29 C15 L30 C16 C17 L31 C18 L32 C19 L33 C20 L34 L35 L36 L37 L38 L39 L40 L41 C21 L42 L43 L44 C22 L45 L46 L47 9' 17' LIMITS OF DISTURBANCE R46' R=296' 20' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT AND PORTION OF BON HOMME RICHARD DRIVE SHALL BE COMPLETED ONCE ALL STREET CUTS FOR UTILITY AND CURB AND GUTTER CONSTRUCTION ARE COMPLETE. 8. BON HOMME RICHARD DRIVE SHALL BE RECONSTRUCTED ONCE ALL STREET CUTS FOR UTILITY CONSTRUCTION ARE COMPLETE. LOT LINES EASEMENT LINES PROPERTY LINE LEGEND NOTES CONCRETE PAVEMENT OR SIDEWALK ASPHALT PAVEMENT CURB & GUTTER CURB & GUTTER T TRANSITION PERMEABLE PAVERS S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP 2" MILL & OVERLAY SAWCUT STREET RECONSTRUCTION RIGHT-OF-WAY CENTERLINE SWALE FLOWLINE LIMITS OF DISTURBANCE 68' ROW S. SHIELDS STREET ENTERPRISE DRIVE NIMITZ DRIVE BON HOMME RICHARD DRIVE ENTERPRISE DRIVE KITTY HAWK COURT 22.25' SAIPAN COURT EP-EP TYPE I DRIVEWAY APPROACH DRIVE-OVER CURB & GUTTER (TYP.) 2' CURB CUT & SIDEWALK CHASE 30' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT STORM INLET PROPERTY BOUNDARY (TYP.) 20' EXISTING DRAINAGE EASEMENT 30' EXISTING SANITARY EASEMENT 20' EXISTING DRAINAGE EASEMENT PROPERTY BOUNDARY (TYP.) STORM INLET 8' UTILITY EASEMENT 2" MILL & OVERLAY (SEE NOTE 7) APPROXIMATE SAWCUT AND PATCH FOR UTILITY CONSTRUCTION (TYP.) RECONSTRUCT EXISTING ENTRANCE WITH UTILITY CONSTRUCTION 2' CURB CUT 26' ACCESS, EMERGENCY ACCESS, UTILITY & DRAINAGE EASEMENT RIBBON CURB (TYP.) 2' CURB CUT & SIDEWALK CHASE 9' UTILITY EASEMENT DRIVE OVER CURB & GUTTER (TYP.) CONNECT TO & MATCH EXISTING PAVEMENT EXISTING DRIVE 15' UTILITY, DRAINAGE, GRADING AND LANDSCAPE EASEMENT ROADWAY RECONSTRUCTION (SEE NOTE 8) BON HOMME RICHARD DRIVE 36' WIDE DUAL DRIVEWAY APPROACH 36' WIDE DUAL DRIVEWAY APPROACH 36' WIDE DUAL DRIVEWAY APPROACH 36' WIDE DUAL DRIVEWAY APPROACH 66' ROW BLOCK 1 BLOCK 2 BLOCK 3 BLOCK 4 BLOCK 4 BLOCK 4 BLOCK 5 BLOCK 9 LOT 1 OUTLOT A LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 TRACT A LOT 1 LOT 2 LOT 3 LOT 4 LOT 1 LOT 2 LOT 6 LOT 5 LOT 4 LOT 3 TRACT B LOT 14 LOT 13 OUTLOT B LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 10 LOT 9 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 (PRIVATE DRIVE) KITTY HAWK COURT (PRIVATE DRIVE) 20' ACCESS EASEMENT 20' ACCESS EASEMENT 4' SIDEWALK 2" MILL & OVERLAY (SEE NOTE 7) (PRIVATE DRIVE) PROPERTY CORNER N:1422515.41 E:3113054.90 PROPERTY CORNER N:1422196.22 E:3112856.49 PROPERTY CORNER N:1422191.28 E:3112790.49 PROPERTY CORNER N:1422008.00 E:3112410.19 APPROXIMATE SAW CUT & PATCH FOR UTILITY CONSTRUCTION PROPERTY CORNER 2" MILL & OVERLAY (SEE NOTE 7) C1 L1 L2 L3 C2 L4 C3 L5 L6 C4 5' SIDEWALK CONNNECT TO EXISTING CURB, GUTTER & SIDEWALK CONNECT TO EXISTING CURB, GUTTER & SIDEWALK RECONSTRUCT SIDEWALK VERTICAL CURB & GUTTER RECONSTRUCT EXISTING CURB RETURN & FILLET WITH DIRECTIONAL RAMPS RECONSTRUCT EXISTING CURB RETURN & FILLET WITH DIRECTIONAL RAMPS T C5 L7 L8 L9 C6 C7 L10 C8 L11 L12 L13 L14 C9 L15 C10 L16 L17 L18 L19 L20 C11 L21 C12 L22 L23 L24 L25 L26 L27 VERTICAL CURB & GUTTER PARKING BLOCK (TYP) 9' 17' RECONSTRUCT CURB, GUTTER & SIDEWALK TO MATCH EXISTING AFTER UTILITY CONSTRUCTION (TYP.) 2' CONC. PAN 20' UTILITY EASEMENT LIMITS OF DISTURBANCE N=1422446.86 E=3112857.20 N=1422370.90 E=3112846.92 N=1422244.74 E=3112845.39 N=1422138.07 E=3112801.02 CURVE TABLE CURVE C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 C18 C19 C20 C21 C22 DELTA ƒ  ƒ  ƒ  ƒ  ƒ  ƒ  ƒ  ƒ  ƒ  ƒ  ƒ  ƒ  ƒ  ƒ  ƒ  ƒ  ƒ  ƒ  ƒ  ƒ  ƒ  ƒ  RADIUS 10.00' 10.00' 15.00' 25.00' 2.00' 2.00' 25.00' 15.00' 25.00' 15.00' 15.00' 25.00' 25.00' 180.00' 180.00' 25.00' 25.00' 150.00' 150.00' 25.00' 26.42' 26.42' LENGTH 16.13' 15.58' 23.56' 37.15' 4.36' 1.98' 40.36' 23.56' 39.27' 23.56' 23.56' 39.27' 39.38' 283.38' 282.10' 24.95' 24.97' 235.09' 236.15' 39.15' 41.50' 41.50' BEARING 6ƒ ( 6ƒ : 6ƒ : 6ƒ ( 1ƒ ( 6ƒ ( 1ƒ ( 1ƒ : 6ƒ : 6ƒ ( 1ƒ ( 1ƒ : 6ƒ : 6ƒ : 1ƒ : 1ƒ : 6ƒ : 6ƒ ( 1ƒ ( 1ƒ : 6ƒ ( 1ƒ ( CHORD 14.44' 14.05' 21.21' 33.83' 3.55' 1.90' 36.12' 21.21' 35.36' 21.21' 21.21' 35.36' 35.43' 255.01' 254.11' 23.93' 23.95' 211.75' 212.51' 35.27' 37.36' 37.36' LINE TABLE LINE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 LENGTH 174.03' 24.58' 174.68' 22.50' 10.00' 21.94' 18.64' 94.69' 21.04' 30.08' 28.59' 24.08' 159.29' 70.90' 36.92' 2.10' BEARING 1ƒ ( 6ƒ ( 6ƒ : 1ƒ : 6ƒ : 6ƒ : 1ƒ : 6ƒ ( 6ƒ ( 1ƒ ( 1ƒ : 1ƒ ( 6ƒ ( 1ƒ : 6ƒ : 6ƒ ( LINE TABLE LINE L17 L18 L19 L20 L21 L22 L23 L24 L25 L26 L27 L28 L29 L30 L31 L32 LENGTH 13.17' 222.17' 13.17' 1.67' 38.77' 68.75' 23.00' 23.00' 20.00' 13.00' 13.00' 86.23' 111.07' 74.05' 74.01' 111.07' BEARING 6ƒ : 1ƒ : 1ƒ ( 6ƒ ( 1ƒ ( 1ƒ : 1ƒ ( 1ƒ : 6ƒ ( 1ƒ ( 1ƒ ( 6ƒ ( 1ƒ : 1ƒ ( 6ƒ ( 6ƒ ( LINE TABLE LINE L33 L34 L35 L36 L37 L38 L39 L40 L41 L42 L43 L44 L45 L46 L47 LENGTH 86.47' 22.90' 22.82' 30.00' 22.98' 22.90' 299.46' 24.58' 20.00' 48.58' 23.17' 48.58' 217.66' 387.69' 406.59' BEARING 1ƒ ( 1ƒ : 1ƒ ( 1ƒ : 1ƒ ( 1ƒ ( 1ƒ : 6ƒ : 6ƒ ( 6ƒ : 6ƒ ( 1ƒ ( 6ƒ ( 6ƒ ( 6ƒ ( * DENOTES EDGE OF CONCRETE * * * * * * * * * * * * * * * DENOTES EDGE OF CONCRETE 6. EXISTING WATER SERVICES AS SHOWN ON THIS DRAWING TO BE REMOVED SHALL BE ABANDONED AT THE MAIN WITH A PLUG IN THE TAP SADDLE PER FORT COLLINS - LOVELAND WATER DISTRICT STANDARDS (LATEST EDITION) LEGEND NOTES LOT LINES EASEMENT LINES CENTERLINE EXISTING MAPPING AND SITE CURB AND GUTTER INTERMEDIATE CONTOUR INDEX CONTOUR EXISTING UTILITIES WATER LINE SANITARY SEWER W SS STORM DRAIN PIPE SANITARY SEWER M.H. STORM SEWER M.H. WATER VALVE FIRE HYDRANT LIGHT POLE WATER / SANITARY PLUG WATER METER WATER VAULT FENCE PROPERTY BOUNDARY S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP RIGHT-OF-WAY 5078 5080 CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 40' 80' SCALE: 1" = 40' 20' REMOVE EXISTING CONCRETE OR SIDEWALK REMOVE EXISTING CURB AND GUTTER SAWCUT LINE REMOVE EXISTING WATER REMOVE EXISTING ASPHALT LIMITS OF DISTURBANCE TREE REMOVAL DEMOLITION LEGEND APPROXIMATE SAWCUT LIMITS FOR UTILITY CONSTRUCTION (TYP.) REMOVE/RELOCATE EXISTING TREES (SEE LANDSCAPE PLANS, TYP.) PROTECT EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT TO BE REMOVED EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT TO BE RELOCATED TO CURB EXISTING BUILDING ENVELOPE TO BE VACATED EXISTING BUILDING ENVELOPE TO BE VACATED EXISTING BUILDING ENVELOPE TO BE VACATED (TYP.) EXISTING RIGHT-OF-WAY TO BE VACATED (TYP.) EXISTING RIGHT-OF-WAY TO BE VACATED (TYP.) EXISTING 36" STORM 15' UTILITY, DRAINAGE, GRADING & LANDSCAPE EASEMENT 30' EXCLUSIVE S. FT. COLLINS SANITARY SEWER EASEMENT REC. NO. 99055752 EXISTING 8" SANITARY SSMH RIM=5076.5 INV 5062.3 8" PVC INV (SE) 5062.1 8" PVC SSMH RIM=5072.9 INV (E) 5053.5 10" PVC INV (S) 5053.6 8" PVC INV (W) 5058.9 8" PVC INV (W) 5053.7 8" PVC SSMH RIM=5065.2 INV (N) 5054.5 8' PVC INV (W) 5054.8 8" PVC SSMH RIM=5074.0 INV (N) 5060.0 8" PVC INV (E) 5059.6 8" PVC INV (W) 5060.0 8" PVC SSMH RIM=5076.3 INV (N) 5062.1 4" PVC INV (E) 5061.6 8" PVC INV (NW) 5061.9 8" PVC SSMH RIM=5078.2 INV (N) 5063.2 8" PVC INV (E) 5063.5 6" PVC INV (S) 5063.1 8" PVC INV (W) 5063.2 8" PVC SSMH RIM=5063.5 INV (E) 5055.9 8" PVC INV (W) 5055.9 8" PVC SSMH INV (E) 5056.5 8" PVC INV (W) 5056.5 8" PVC SSMH RIM=5061.9 INV (E) 5056.6 8" PVC INV (S) 5056.7 8" PVC SSMH RIM=5075.4 INV (N) 5060.8 8" PVC INV (S) 5060.5 8' PVC PROTECT EXISTING TELECOM EXISTING FIRE HYDRANT EXISTING STOCKPILE PROPERTY BOUNDARY (TYP.) ROAD TO BE RECONSTRUCTED WITH UTILITY CONSTRUCTION (TYP.) EXISTING 10" WATER EXISTING 8" SANITARY 66' ROW 54' ROW PROPERTY BOUNDARY (TYP.) EXISTING FIRE HYDRANT EXISTING BUILDING ENVELOPE TO BE VACATED (TYP.) EXISTING BUILDING ENVELOPE TO BE VACATED (TYP.) REMOVE EXISTING CURB REMOVE EXISTING SIDEWALK REMOVE EXISTING CURB REMOVE EXISTING SIDEWALK FES=5063.6 FES=5068.4 INLET RIM=5072.7 INV (N) 5067.2 36" RCP INV (S) 5066.8 36" RCP INLET INV (N) 5068.7 36" RCP INV (S) 5068.7 36" RCP CITY HIGH RISK FLOODWAY REMOVE EXISTING CURB REMOVE EXISTING CURB REMOVE EXISTING SIDEWALK REMOVE EXISTING CURB REMOVE EXISTING SIDEWALK 68' ROW REMOVE EXISTING CURB REMOVE EXISTING SIDEWALK PROTECT EXISTING TELECOM EXISTING 1.5" WATER SERVICE PROTECT EXISTING TO BE REMOVED (TYP.) TELECOM REMOVE EXISTING CURB REMOVE EXISTING CONC. FILLET & CURB REMOVE EXISTING CURB REMOVE EXISTING CURB REMOVE EXISTING CURB REMOVE EXISTING SIDEWALK EXISTING LIGHT TO BE RELOCATED (SEE UTILITY PLANS C300-C301) EXISTING GAS STUB FOR DEVELOPMENT (STUB TO BE SHORTENED AND CONNECTED TO WITHIN UTILITY EASEMENT TO THE NORTH) REMOVE EXISTING TREE (SEE LANDSCAPE PLANS, TYP.) LIMITS OF DISTURBANCE 30' EXCLUSIVE S. FT. COLLINS SANITARY SEWER EASEMENT REC. NO. 99055752 REMOVE EXISTING ENTRANCE 6. EXISTING WATER SERVICES AS SHOWN ON THIS DRAWING TO BE REMOVED SHALL BE ABANDONED AT THE MAIN WITH A PLUG IN THE TAP SADDLE PER FORT COLLINS - LOVELAND WATER DISTRICT STANDARDS (LATEST EDITION) LEGEND NOTES LOT LINES EASEMENT LINES CENTERLINE EXISTING MAPPING AND SITE CURB AND GUTTER INTERMEDIATE CONTOUR INDEX CONTOUR EXISTING UTILITIES WATER LINE SANITARY SEWER W SS STORM DRAIN PIPE SANITARY SEWER M.H. STORM SEWER M.H. WATER VALVE FIRE HYDRANT LIGHT POLE WATER / SANITARY PLUG WATER METER WATER VAULT FENCE PROPERTY BOUNDARY S. SHIELDS STREET BON HOMME RICHARD DRIVE ENTERPRISE DRIVE NIMITZ DRIVE TRUXUN DRIVE VINSON STREET KEYMAP RIGHT-OF-WAY 5078 5080 CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: 0 40' 80' SCALE: 1" = 40' 20' REMOVE EXISTING CONCRETE OR SIDEWALK REMOVE EXISTING CURB AND GUTTER SAWCUT LINE REMOVE EXISTING WATER REMOVE EXISTING ASPHALT LIMITS OF DISTURBANCE TREE REMOVAL DEMOLITION LEGEND APPROXIMATE SAWCUT LIMITS FOR UTILITY CONSTRUCTION (TYP.) APPROXIMATE SAWCUT LIMITS FOR UTILITY CONSTRUCTION (TYP.) REMOVE/RELOCATE EXISTING TREES (SEE LANDSCAPE PLANS, TYP.) REMOVE EXISTING ENTRANCE PROTECT EXISTING TRANSFORMER EXISTING BUILDING ENVELOPE TO BE VACATED EXISTING BUILDING ENVELOPE TO BE VACATED EXISTING 1.5" WATER SERVICE TO BE REMOVED (TYP.) PROTECT EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT TO BE REMOVED EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT TO BE RELOCATED TO CURB REMOVE EXISTING CURB EXISTING BUILDING ENVELOPE TO BE VACATED EXISTING BUILDING ENVELOPE TO BE VACATED SSMH RIM=5076.5 INV 5062.3 8" PVC INV (SE) 5062.1 8" PVC SSMH RIM=5072.9 INV (E) 5053.5 10" PVC INV (S) 5053.6 8" PVC INV (W) 5058.9 8" PVC INV (W) 5053.7 8" PVC SSMH RIM=5074.0 INV (N) 5060.0 8" PVC INV (E) 5059.6 8" PVC INV (W) 5060.0 8" PVC SSMH RIM=5076.3 INV (N) 5062.1 4" PVC INV (E) 5061.6 8" PVC INV (NW) 5061.9 8" PVC SSMH RIM=5078.2 INV (N) 5063.2 8" PVC INV (E) 5063.5 6" PVC INV (S) 5063.1 8" PVC INV (W) 5063.2 8" PVC SSMH RIM=5075.4 INV (N) 5060.8 8" PVC INV (S) 5060.5 8' PVC SSMH RIM=5076.6 INV (N) 5062.7 8" PVC INV (S) 5062.6 8" PVC SSMH RIM=5076.3 INV (NW) 5062.4 8' PVC INV (S) 5062.3 8" PVC SSMH RIM=5076.9 INV (N) 5064.0 8" PVC INV (E) 5064.1 6" PVC INV (SW) 5064.0 6" PVC EXISTING 30" STORM DRAIN EXISTING 8" SANITARY EXISTING 8" WATER PROTECT EXISTING TELECOM DMH RIM=5075.0 INV (S) 5070.0 30" ADS INV (W) 5070.0 30" ADS DMH RIM=5075.9 INV (N) 5072.2 20" ADS INV (E) 5071.5 24" RCP INV (W) 5071.5 20" ADS INLET GRATE=5076.7 INV (S) 5072.5 20" ADS INLET RIM=5074.9 INV (W) 5070.2 24" RCP INV (E) 5070.2 30" RCP INLET RIM=5075.0 INV (E) 5070.7 24" RCP EXISTING FIRE HYDRANT EXISTING STOCKPILE REMOVE EXISTING ENTRANCE PROPERTY BOUNDARY (TYP.) PROPERTY BOUNDARY (TYP.) ROAD TO BE RECONSTRUCTED WITH UTILITY CONSTRUCTION (TYP.) EXISTING 10" WATER EXISTING 8" SANITARY 66' ROW 54' ROW EXISTING FIRE HYDRANT EXISTING BUILDING ENVELOPE TO BE VACATED (TYP.) REMOVE EXISTING CURB REMOVE EXISTING SIDEWALK REMOVE EXISTING CURB REMOVE EXISTING SIDEWALK INLET RIM=5072.7 INV (N) 5067.2 36" RCP INV (S) 5066.8 36" RCP REMOVE EXISTING SIDEWALK REMOVE EXISTING CURB REMOVE EXISTING SIDEWALK REMOVE EXISTING CURB REMOVE EXISTING CURB REMOVE EXISTING SIDEWALK REMOVE EXISTING CURB REMOVE EXISTING SIDEWALK 68' ROW REMOVE EXISTING CURB REMOVE EXISTING SIDEWALK PROTECT EXISTING TELECOM EXISTING 1.5" WATER SERVICE PROTECT EXISTING TO BE REMOVED (TYP.) TELECOM REMOVE EXISTING CURB REMOVE EXISTING CONC. FILLET & CURB REMOVE EXISTING CURB REMOVE EXISTING CURB REMOVE EXISTING CURB REMOVE EXISTING SIDEWALK REMOVE EXISTING SIDEWALK REMOVE EXISTING CURB EXISTING BUILDING ENVELOPE TO BE VACATED REMOVE EXISTING CURB EXISTING LIGHT TO BE RELOCATED (SEE UTILITY PLANS C300-C301) EXISTING LIGHT TO BE RELOCATED (SEE SHEET C300) EXISTING GAS STUB FOR DEVELOPMENT (STUB TO BE SHORTENED AND CONNECTED TO WITHIN UTILITY EASEMENT TO THE NORTH) DMH RIM=5075.3 INV (E) 5070.8 24" RCP INV (W) 5070.8 24" RCP DMH RIM=5076.4 INV (N) 5072.7 24" ADS INV (E) 5071.3 30" ADS INV (W) 5071.8 24" ADS LIMITS OF DISTURBANCE REMOVE EXISTING ENTRANCE 5,000 SQ.FT. LOT 3 5,000 SQ.FT. LOT 4 6,719 SQ.FT. LOT 1 5,410 SQ.FT. LOT 2 6,744 SQ.FT. LOT 3 7,887 SQ.FT. LOT 4 6,784 SQ.FT. LOT 1 5,750 SQ.FT. LOT 2 6,384 SQ.FT. LOT 3 7,375 SQ.FT. LOT 4 6,927 SQ.FT. LOT 5 7,358 SQ.FT. LOT 6 7,414 SQ.FT. LOT 7 7,138 SQ.FT. LOT 8 7,113 SQ.FT. LOT 9 5,744 SQ.FT. LOT 10 6,291 SQ.FT. DEDICATED PUBLIC RIGHT OF WAY BY THIS PLAT BLOCK 5 BLOCK 6 BLOCK 7 BLOCK 9 BLOCK 8 BLOCK 10 43,292 SQ.FT. 0.994 ACRES BLOCK 8 OUTLOT C 67,261 SQ.FT. 1.544 ACRES OUTLOT C 67,261 SQ.FT. 1.544 ACRES OUTLOT C 67,261 SQ.FT. 1.544 ACRES BLOCK 9 BLOCK 5 LEGEND SHEET 3 SHEET 3 SHEET 5 SHEET 4 SHEET INDEX KING SURVEYORS 650 E. Garden Drive | Windsor, Colorado 80550 phone: (970) 686-5011 | fax: (970) 686-5821 5 SEE SHEET 3 OF 5 SEE SHEET 4 OF 5 SEE SHEET 4 OF 5 SEE SHEET 3 OF 5 ** SEE SHEET 2 OF 5 FOR LINE AND CURVE TABLE ** N:\2014615\DWG\2014615SUB.dwg, 3/17/2015 8:23:25 AM OUTLOT B 16,800 SQ.FT. 0.386 ACRES LEGEND SHEET 3 SHEET 3 SHEET 5 SHEET 4 SHEET INDEX KING SURVEYORS 650 E. Garden Drive | Windsor, Colorado 80550 phone: (970) 686-5011 | fax: (970) 686-5821 4 SEE SHEET 3 OF 5 SEE SHEET 3 OF 5 SEE SHEET 5 OF 5 SEE SHEET 5 OF 5 ** SEE SHEET 2 OF 5 FOR LINE AND CURVE TABLE ** N:\2014615\DWG\2014615SUB.dwg, 3/17/2015 8:23:20 AM 650 E. Garden Drive | Windsor, Colorado 80550 phone: (970) 686-5011 | fax: (970) 686-5821 3 SEE SHEET 4 OF 5 SEE SHEET 4 OF 5 SEE SHEET 5 OF 5 SEE SHEET 5 OF 5 SEE SHEET 4 OF 5 ** SEE SHEET 2 OF 5 FOR LINE AND CURVE TABLE ** N:\2014615\DWG\2014615SUB.dwg, 3/17/2015 8:23:15 AM 6 7 7 7 7 8 9 8 8 9 10 8 10 TRACT D 8 9 10 11 12 13 14 LEGEND SHEET 3 SHEET 3 SHEET 5 SHEET 4 SHEET INDEX KING SURVEYORS 650 E. Garden Drive | Windsor, Colorado 80550 phone: (970) 686-5011 | fax: (970) 686-5821 2 Being a Replat Of Tract B And A Portion of Tract A, Of The Registry Ridge P.U. D., Second Filing, And Of All Of Registry Ridge Fourth Filing City Of Fort Collins, County Of Larimer, State Of Colorado (For Recording Purposes: Part of The Northeast Quarter of Section 15, Township 6 North, Range 69 West of The 6th P.M.) CURVE DATA NOTE: Was unable to reconcile all the curve data components on curves C5, C6, C7 & C8 to match perfectly with the previous plat data. Elected to hold the Delta Angle component on those 4 curves and allow the Chord Bearing component to be the variable data. CURVE DATA NOTE: Was unable to reconcile all the curve data components on curves C5, C6, C7 & C8 to match perfectly with the previous plat data. Elected to hold the Delta Angle component on those 4 curves and allow the Chord Bearing component to be the variable data. N:\2014615\DWG\2014615SUB.dwg, 3/17/2015 8:23:10 AM infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The storm water volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the city/county or Homeowners Association (HOA). 13. City ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The developer shall implement whatever measures are determined necessary, as directed by the city/county. 16. A vehicle tracking control pad shall be installed when needed for construction equipment, including but not limited to personal vehicles exiting existing roadways. No earthen materials, i.e. stone, dirt, etc. shall be placed in the curb & gutter or roadway as a ramp to access temporary stockpiles, staging areas, construction materials, concrete washout areas, and/or building sites. FORT COLLINS-LOVELAND WATER DISTRICT NOTES 1. All waterlines shall be C900, DR 18 PVC pipe with a minimum 12 gage insulated tracer wire. 2. All waterlines shall be buried a minimum of 5 feet below finished grade. Maximum cover shall be 6.0'. 3. Maintain 10 feet of horizontal separation and 18 inches of vertical separation between all sanitary and storm sewer and water mains and services. 4. All water services require meter pit installation. LARIMER COUNTY URBAN AREA STREET STANDARDS - REPEALED AND REENACTED OCTOBER 1, 2002 GENERAL NOTES 1. All materials, workmanship, and construction of public improvements shall meet or exceed the Standards and Specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the local entity. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the local entity engineer. Use of these plans after the expiration date will require a new review and approval process by the local entity prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the local entity, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the local entity engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the local entity, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All sanitary sewer, storm sewer, and water line construction, as well as power and other "dry" utility installations, shall conform to the local entity standards and specifications current at the date of approval of the plans by the local entity engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The developer shall be responsible for unknown underground utilities. 7. The developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the local entity prior to beginning construction. 10. The developer shall coordinate and cooperate with the local entity, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is4.5 feet and the maximum is 5.5 fee unless otherwise noted in the plans and approved by the Water Utility. 14. A state construction dewatering wastewater discharge permit is required if dewatering is required in order to install utilities or water is discharged into a storm sewer, channel, irrigation ditch or any waters of the united states. 15. The developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the storm water management plan, and the erosion control plan. 16. The local entity shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the local entity, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the storm water utility department. Certification shall be submitted to the storm water utility department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Storm Water Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the development agreement. 18. The local entity including but not limited to City of Fort Collins, South Fort Collins Sanitation District and Fort Collins-Loveland Water District shall not be responsible for any damages or injuries sustained in this development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the local entity failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the final drainage and erosion control study entitled "Registry Ridge Seventh Filing" prepared by United Civil Design Group LLC, and dated March 18, 2015, shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the erosion control plan. All erosion control measures shall be maintained in good repair by the developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the local entity street inspector. 22. No work may commence within any improved or unimproved public right-of-way until a right-of-way permit or development construction permit is obtained, if applicable. 23. The developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The developer shall notify the local entity engineering inspector (Fort Collins - 221-6605) and the local entity erosion control inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the local entity engineer is not available after proper notice of construction activity has been provided, the developer may commence work in the engineers absence. However, the local entity reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The developer shall be responsible for obtaining soils tests within the public right-of-way after right-of-way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the developer shall be responsible for a re-design of the subject pavement section or, the developer may use the local entity's default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed professional engineer. The final report shall be submitted to the inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the local entity engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the local entity inspector. The engineer or surveyor must certify in a letter to the local entity that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the local entity before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County floodplain resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as wild fire hazard areas shall be done in accordance with the construction criteria as established in the wild fire hazard area mitigation regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the local entity forester to schedule a site inspection for any tree removal requiring a permit. 30. The developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The developer shall submit a construction traffic control plan, in accordance with MUTCD, to the appropriate right-of-way authority. (local entity, county or state), for approval, prior to any construction activities within, or affecting, the right-of-way. The developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact local entity traffic operations department, who will temporarily remove or relocate the sign at no cost to the contractor; however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The developer is responsible for all costs for the initial installation of traffic signing and striping for the development related to the development's local street operations. In addition, the developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the local entity engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by the local entity. 35. The developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the designer for clarification, and annotate the dimension on the as-built record drawings. 37. The developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the developer shall contact the designer and the local entity engineer immediately. 39. The developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the local entity's inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the local entity engineer. GENERAL NOTES (CONTINUED) 40. The designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: VERTICAL DATUM: PROJECT VERTICAL DATUM IS NAVD 88. BENCHMARK #1: CITY OF FORT COLLINS 10-13 SOUTHEAST CORNER OF SHIELDS ST. AND TRILBY ROAD. , ON A CONCRETE TRAFFIC SIGNAL BASE. ELEVATION=5066.93 (NAVD 88 DATUM) BENCHMARK #2: CITY OF FORT COLLINS 45-01 SOUTH SIDE OF TRILBY ROAD, APPROXIMATELY 0.5 MILES EAST OF TAFT HILL ROAD, ON AN 8'x8' CONCRETE PAD FOR A WATER VALVE AND A LARGE BLACK PIPE. ELEVATION=5069.38 (NAVD 88 DATUM) BASIS OF BEARINGS: $6680,1*7+(($67/,1(2)7+(1257+($6748$57(52)6(&7,21715:$6%($5,1*1257+ƒ ($67%(,1*$*5,'%($5,1* OF THE COLORADO STATE PLANE COORDINATE SYSTEM, NORTH ZONE, NORTH AMERICAN DATUM 1983/2007, A DISTANCE OF 2640.82 FEET WITH ALL OTHER BEARINGS CONTAINED HEREIN RELATIVE THERETO. 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first certificate of occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the local entity construction inspector before any cuts are made. Patching shall be done in accordance with the local entity street repair standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the local entity engineer and/or the local entity inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the local entity, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The local entity shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: none. 48. Approved variances are listed as follows: -None. STREET IMPROVEMENTS NOTES 1. All street construction is subject to the General Notes on the Cover Sheet of these plans as well as the street improvements notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed engineer, must be submitted to the local entity engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the local entity engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the local entity engineer. 5. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, reconstruction and repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the local entity engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in MUTCD (including Colorado supplement) and as per the right-of-way work permit traffic control plan. 8. The developer is required to perform a gutter water flow test in the presence of the local entity inspector and prior to installation of asphalt. Gutters that hold more than inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. And a single axle weight of at least 18,000 lbs. With pneumatic tires inflated to not less than 90 P.S.I.G. "proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the local entity engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The local entity engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be performed in the presence of an inspector. STORM DRAINAGE NOTES 1. All street, sanitary sewer, storm sewer and water construction shall conform to City Standards and Specifications current at date of execution of the Development Agreement pertaining to this development. Any construction occurring three years after the execution of the development agreement shall require re-examination of the plans by the Director who may require that they be made to conform to standards and specifications current at that time. 2. The type, size, location, and number of all known underground utilities are approximate as shown on the drawings. It shall be the responsibility of the contractor to verify the existence and location of all underground utilities along the route of the work. Before commencing new construction, the contractor shall be responsible for locating unknown underground utilities. 3. These plans have been reviewed by the City for concept only. The review does not imply responsibility by the reviewing department, the City Engineer, or the City for accuracy or correctness of the calculations. Furthermore, the review does not imply that the quantities of the items on the plans are the final quantities required. The review shall not be construed in any reason as acceptance of financial responsibility by the City for additional quantities of items shown that may be required during the construction phase. 4. Prior to the commencement of any construction, the contractor must give the City Engineering Department (970-221-6605) and the Erosion Control Inspector (970-221-6700) twenty-four (24) hours advance. Initial erosion control measures must be installed and a site inspection by the Erosion Control Inspector is required before commencing construction activities. 5. Maintenance of onsite drainage facilities shall be the responsibility of the property owners. 6. All recommendations of the final drainage and erosion control study entitled "Registry Ridge Seventh Filing" prepared by United Civil Design Group LLC, and dated March 18, 2015, shall be followed and implemented. 7. Prior to final inspection and acceptance by the City, certification of the drainage facilities by a Colorado registered professional engineer must be submitted to and approved by the City Stormwater Department. (including the applicable note as set forth below) For commercial and multi-family developments, certification of all drainage facilities shall be submitted to the City Stormwater Department at least two weeks prior to the release of a certificate of occupancy. Individual lot certification, elevation certification, or floodproofing certification, as specified in the development agreement, must be submitted to the City Stormwater Department at least two weeks prior to the release of a certificate of occupancy for such lot. For single family developments, certification of all drainage facilities must be submitted to the City Stormwater Department in accordance with all conditions as prescribed by the development agreement associated with this development. Individual lot certification, elevation certification, or floodproofing certification, as specified in the development agreement, must be submitted to the City Stormwater Department at least one week prior to the release of a certificate of occupancy for such lot. 8. If dewatering is used to install utilities, and discharge will be into the street, gutter, storm sewer, channel, irrigation ditch, or any waters of the State a State Construction Dewatering Industrial Wastewater Discharge Permit is required. 9. All land disturbing activities greater than or equal to one acre must comply with the State of Colorado permitting process for Stormwater Discharges Associated with Construction Activity. For more information contact the Colorado Department of Public Health and Environment, Water Quality Control Division, at 303-692-3500 or refer to the web site at http://www.cdphe.state.co.us/wq/PermitsUnit/. 10. Benchmark: See General Note Number 40. 11. If fill or dredged material is discharged into waters of the United States, a USACE 404 permit is required. 12. If construction affects any Colorado Highway, a Colorado Department of Transportation right-of-way permit is required. CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: GENERAL NOTES C001 N/A N/A ASSUMING THE EAST LINE OF THE NORTHEAST QUARTER OF SECTION 15, T.6N., R.69W., $6%($5,1*1257+ƒ ($67%(,1*$*5,'%($5,1*2)7+(&2/25$'267$7( PLANE COORDINATE SYSTEM, NORTH ZONE, NORTH AMERICAN DATUM 1983/2007, A DISTANCE OF 2640.82 FEET WITH ALL OTHER BEARINGS CONTAINED HEREIN RELATIVE THERETO. NOTE: 1. ALL PROJECT CONTROL LISTED HEREON IS PROVIDED AS A COURTESY. IT IS THE RESPONSIBILITY OF THE RECIPIENT TO VERIFY THE ACCURACY OF THE COORDINATES AND ELEVATIONS SHOWN PRIOR TO USING THEM FOR ANY PURPOSES. UTILITY PROVIDER CONTACT PHONE Water/Wastewater Fort Collins - Loveland Water District Terry Farrill (970) 226-3104 & South Fort Collins Sanitation District Stormwater City of Fort Collins Utilities Glen Schlueter (970) 221-6700 Power City of Fort Collins Light & Power Jim Spaulding (970) 416-2772 Natural Gas Xcel Energy Stephanie Rich (970) 225-7828 Telecom Centurylink Bill Johnson (970) 377-6401 Cable Comcast Don Kapperman (970) 567-0245 Note: All utility providers listed hereon is provided as a courtesy. It is the responsibility of the recipient to verify the accuracy and completeness of the information shown. UTILITY PROVIDERS PREPARED FOR: DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. CAUTION BQ, LLC. 3/18/2015 U14012 PRELIMINARY PLANS NOT FOR CONSTRUCTION 1501 Academy Ct. Ste. 203 Fort Collins, CO 80524 (970) 530-4044 www.unitedcivil.com Civil Engineering & Consulting REGISTRY RIDGE SEVENTH FILING CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: APPROVED: CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's R Mr. Terry W. Farrill, P.E., District Engineer Mr. Michael D. DiTullio, Manager Date Date All changes, addendum, additions, deletions and modifications to these drawings must be approved in writing, by the Fort Collins - Loveland Water District and the South Fort Collins Sanitation District. SHEET INDEX SHEET # SHEET NAME C000 COVER SHEET C001 GENERAL NOTES SUBDIVISION PLAT (FOR REFERENCE ONLY) C100-C101 EXISTING CONDITIONS & REMOVALS C200-C201 HORIZONTAL CONTROL & PAVEMENT PLAN C300-C301 UTILITY PLAN C400-C402 SANITARY SEWER PLAN & PROFILES C500-C501 STORM SEWER PLAN & PROFILES C600-C601 OVERLOT GRADING & EROSION CONTROL PLAN C602-C603 DETAILED GRADING PLANS C700 HORNET DRIVE STREET PLAN C701 HORNET DRIVE STREET PROFILES C702-C703 INTERSECTION DETAILS C704-C705 SIGNING & STRIPING PLAN C800 DRAINAGE PLAN C900-C909 CONSTRUCTION DETAILS PLANNER/LANDSCAPE ARCHITECT GREENSCAPE DESIGNS 1501 ACADEMY CT., STE 202 FORT COLLINS, CO 80524 PHONE: 970-631-2822 CONTACT: JENNIFER GARDNER COVER SHEET C000 N/A N/A PROJECT SITE S. SHIELDS STREET W. TRILBY ROAD B O N H O M M E R I C H A R D DRIVE TRUXUN DRIVE