HomeMy WebLinkAboutREGISTRY RIDGE SEVENTH FILING, REPLAT OF FILINGS TWO & FOUR - FDP - FDP150015 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORT1501 Academy Ct. Ste. 203 Fort Collins, Colorado 80524 (970) 530-4044
Final Drainage Addendum
Registry Ridge Seventh
Filing
Fort Collins, CO
Prepared for:
BQ, LLC
10221 Prestwick Trail
Lone Tree, CO 80124
March 18, 2015
Drainage Addendum
Registry Ridge Seventh Filing
Fort Collins, CO
1 U14012-DrainageAddendum-Final.doc
March 18, 2015
City of Fort Collins
Stormwater Utility
700 Wood Street
Fort Collins, Colorado 80521
RE: Registry Ridge Seventh Filing
Fort Collins, Colorado
Project Number: U14012
Dear Staff:
United Civil Design Group, LLC. is pleased to submit this Final Drainage Addendum for the
Registry Ridge Seventh Filing site in Fort Collins, Colorado. In general, this summary serves to
document the stormwater impacts associated with the proposed project and to verify that the
project does conform to the intent and requirements set forth in the following approved final
drainage reports:
• “Final Drainage Report for Registry Ridge P.U.D., Second Filing”, prepared by TST, Inc.
and dated November 6, 2000.
• “Drainage Design Considerations for Registry Ridge P.U.D., Fourth Filing”, by Northern
Engineering Services, Inc. and dated December 5, 2001.
Site Location and Project Description
The Registry Ridge Seventh Filing development site (referred herein as ”the site”) is located in
the northeast quarter of Section 15, Township 6 North, Range 69 West of the Sixth P.M., City of
Fort Collins, Larimer County, Colorado and consists of portions of two (2) previous filings of the
subdivision, the Second Filing north of Bon Homme Richard Drive and the Fourth Filing south of
Bon Homme Richard Drive. The site has a platted area of 11.83 acres and is bounded by South
Shields Street to the east, Truxon Drive to the north, and Registry Ridge First and Third Filings
to the west and south. See the attached Drainage Plan for additional information.
The planned development is separated into three distinct areas separated by existing public
right-of way. For clarity, the three development areas are designated as the “Northeast Area”,
North Central Area”, and “South Area” within this report. In total, the development will consist
of the following:
• Twenty-eight (28) single family duplex buildings with fifty-six (56) total units.
• Eighteen (18) single family detached lots.
• A public roadway and private drives in support of the development.
• The construction of utilities to support the development including sanitary, water
and storm drainage.
Drainage Addendum
Registry Ridge Seventh Filing
Fort Collins, CO
2 U14012-DrainageAddendum-Final.doc
Existing Conditions
Hydrology
The site, which is located within the Fossil Creek Drainage Basin, is divided into three
areas that are separated by existing roadways. Each area is described as follows:
Northeast Area
The northeast area consists of 1.41 acres and is covered with grasses and weeds.
The area has been previously overlot graded and currently drains from west to east
towards South Shields Street. Ultimately, the Second Filing shows that a portion of
the site will continue drain to Shields Street with the remainder being graded
towards Enterprise Drive to the east where runoff will be intercepted by existing
storm drainage and conveyed to the existing water quality and detention pond
located south of the development.
North Central Area
The north central area consists of 2.72 acres and is currently adjacent to active
construction and is being utilized as a construction staging area. The area has been
previously overlot graded and currently drains from west to east towards Enterprise
Drive. Ultimately, the Second Filing shows that the site will continue drain to
Enterprise Drive to the east where runoff will be intercepted by existing storm
drainage and conveyed to the existing water quality and detention pond located
south of the development.
South Area
The south area consists of 8.15 acres and is covered with grasses and weeds. The
area has been previously overlot graded and currently drains from north to south
towards the existing water quality and detention pond located south of the
development.
Floodplain
The site is not located within a FEMA or City-regulatory floodway or floodplain. The
nearest City-regulatory high risk floodway is located south of the site within the existing
detention pond area. No improvements are being proposed within this area.
Detention
The regional detention pond located just south of the development provides both
detention and water quality for the site and is not being modified with this project.
Developed Conditions
In part, the intent of this Drainage Addendum is to verify that the Seventh Filing project
conforms to the intent and requirements set forth in the previous drainage reports for this site.
As such, the following sections of this Addendum compare the proposed design for the
Seventh Filing to the design as shown in aforementioned reports for both the Second and
Fourth Filings.
Drainage Addendum
Registry Ridge Seventh Filing
Fort Collins, CO
3 U14012-DrainageAddendum-Final.doc
Hydrology
Northeast Area
Basin A as shown in the attached Drainage Plan contains the entirety of the
northeast area of the development. The majority of the basin is collected via
streets and storm sewer and routed to the regional pond south of the site, matching
the drainage patterns set forth in the Second Filing report. The following table
compares the characteristics of Basin A to the same area as shown in the drainage
report for the Second Filing:
Comparison Summary Table
Basin A
Second
Filing
Overall Area (acres) 1.41 1.41
Impervious Area (acres) 0.55 0.71
% Imperviousness 37% 47%
Area Draining to Shields
(acres) 0.63 0.55
As shown in the above table, the proposed improvements for the Seventh Filing
result in lower impervious areas from those shown in the approved TST report. In
addition, the drainage patterns as shown in the Second Filing report have remained
largely unchanged. Therefore, the proposed Seventh Filing improvements for the
northeast area appear to meet the intent and requirements set forth in the original
TST report and it is anticipated that the Seventh Filing improvements will not have a
negative impact to the existing downstream drainage facilities.
North Central Area
Basin B as shown in the attached Drainage Plan contains the entirety of the north
central area of the development. The entirety of the basin is collected via streets
and storm sewer and routed to the regional pond south of the site, matching the
drainage patterns set forth in the Second Filing report. The following table
compares the characteristics of Basin B to the same area as shown in the drainage
report for the Second Filing:
Comparison Summary Table
Basin B
Second
Filing
Overall Area (acres) 2.27 2.27
Impervious Area (acres) 1.26 1.41
% Imperviousness 52% 58%
Drainage Addendum
Registry Ridge Seventh Filing
Fort Collins, CO
4 U14012-DrainageAddendum-Final.doc
As shown in the previous table, the proposed improvements for the Seventh Filing
result in lower impervious areas from those shown in the approved TST report. In
addition, the drainage patterns as shown in the Second Filing report have remained
largely unchanged. Therefore, the proposed Seventh Filing improvements for the
north central area appear to meet the intent and requirements set forth in the
original TST report and it is anticipated that the Seventh Filing improvements will
not have a negative impact to the existing downstream drainage facilities.
South Area
Basin C as shown in the attached Drainage Plan contains the entirety of the south
area of the development. The entirety of the basin is collected via swales, streets,
and storm sewer and routed to the regional pond south of the site, matching the
drainage patterns set forth in the Second Filing report. The following table
compares the characteristics of Basin C to the same area as shown in the drainage
report for the Fourth Filing:
Comparison Summary Table
Basin C
Fourth
Filing
Overall Area (acres) 8.15 8.15
Impervious Area (acres) 3.74 3.91
% Imperviousness 41% 45%
As shown in the above table, the proposed improvements for the Seventh Filing
result in lower impervious areas from those shown in the approved Northern
Engineering report. In addition, the drainage patterns as shown in the Fourth Filing
report have remained largely unchanged. Therefore, the proposed Seventh Filing
improvements for the northeast area appear to meet the intent and requirements
set forth in the original Northern Engineering report and it is anticipated that the
Seventh Filing improvements will not have a negative impact to the existing
downstream drainage facilities.
Storm Sewer
Storm Sewer Lines 1-2 are located in the south area of the proposed development and
collect runoff from Basins C2-C6. . Storm line 1 is the outlet system from the PLD pond
to the existing detention pond south of the development. In order to eliminate as
much surface water as possible through Basin C6 due to erosion concerns, Storm Line 2
will be designed to convey the 100-year flows away from the site and into the
downstream porous landscape detention (PLD) area being designed with this project.
Storm Sewer Line 3 is located in the south area of the proposed development and
collects runoff from Basin C8 and the underdrain for the permeable pavers being
Drainage Addendum
Registry Ridge Seventh Filing
Fort Collins, CO
5 U14012-DrainageAddendum-Final.doc
designed for the private drive within the basin. The storm line will discharge runoff into
the existing drainage swale on the south side of the property which delivers runoff to
the existing detention pond.
Storm Line 4 is located south of the proposed development and is designed to convey
100-year events under the proposed trail crossing the existing drainage channel. The
dual box culverts will convey 160 cfs per the Fourth Filing Drainage Report. It should be
noted, from survey obtained to design the proposed trail that the existing channel as it
was constructed appears to have insufficient capacity to convey the 100-year event
immediately downstream of the proposed trail crossing. This area is not located within
the proposed development property boundaries, is outside of the improvements being
made for the trail, and is outside the limits of the scope of this project; however, it
appears that the 100-year event downstream of the trail crossing would partially
submerge adjacent residential lots.
Storm Sewer Line 5 is located in the north central area of the proposed development
and collects runoff from Basin B1. The storm line will connect to the existing 30-inch
storm drain on the north end of the site which is the same system the runoff drains to
in the Second Filing report.
Storm Sewer Line 6 is located in the northeast area of the proposed development and
collects runoff from Basin A3. This storm line has been added in order to minimize the
amount of runoff being released to South Shields Street and to help minimize the
amount of fill required for the area. The storm line will connect to the existing 30-inch
storm drain on the south end of the site which is the same system the runoff draining
to Enterprise Drive enters (Basins A1 and A2).
Refer to the Appendix for hydraulic calculations for each storm sewer system.
Detention and Water Quality Requirements
As previously mentioned, the site is provided with detention and water quality from the
regional pond just south of the site. With the Seventh Filing development not
exceeding the assumptions made during the design of the regional facility, no further
detention or water quality improvements are required with the Seventh Filing.
Low Impact Development (LID) Requirements
In February of 2013, City Council adopted the LID policy and criteria. The Seventh Filing
of Registry Ridge is required to meet the newly adopted criteria. Per the criteria, the
site must:
• Treat no less than 50% of any newly added impervious area using one or a
combination of LID techniques.
• Treat no less than 25% of any newly added pavement area using a permeable
pavement.
Drainage Addendum
Registry Ridge Seventh Filing
Fort Collins, CO
6 U14012-DrainageAddendum-Final.doc
The northeast and north central areas of the development are located within previously
approved developments and are now considered “infill” sites as infrastructure
improvements for these areas area complete. Due to this, and in communication with
City personnel, the north areas of the development will not be treated with LID
techniques. The south area of the development will be treated with various LID
techniques and the overall treatment of the project will be as close to 50% as feasible;
however, per communication with City personnel, the 50% requirement will not be
strictly enforced due to the portions of the site unavailable for treatment.
The following measures are being implemented within the south area of the proposed
development:
Porous Landscape Detention (PLD)
Basins C2-C6 (with 2.04 acres of impervious area) will be routed through a PLD
being designed with this project. The PLD has an average depth of 8-inches (12-
inches maximum) with an overall volume of 4,429 cubic feet which exceeds the
minimum design requirements for the area. Refer to the Appendix for additional
PLD calculations.
Permeable Pavers
Basin C8 (with 0.512 acres of impervious area) will be routed over permeable
pavers being designed within the private drive within the basin. The pavers will
be designed with an underdrain that terminates at a proposed storm inlet at
Storm Line 3. The development has a total of 0.70 acres of pavement being
designed within private drives for the development. The permeable paver area
totals 0.20 acres, or 28.6% of the total private pavement area for the project.
In total, the south area is proposing to collect and treat 2.56 acres (46.0%) of the
overall 5.56 acres of impervious area developed with this project. In addition,
the site is also being designed with other various open landscaped areas, grass
buffers and vegetated swales to provide additional water quality in addition to
the areas being treated with the PLD or permeable pavers.
Four Step Process
With the adoption of the USDCM, the City has also adopted the “Four Step Process”
that is recommended in Volume 3 of the USDCM in selecting structural BMPs for the
redeveloping urban areas. The following portions of this addendum describe each step
and how it has been utilized for this project:
Step 1 – Employ Runoff Reduction Practices
The objective of this step is to reduce runoff peaks and volumes and to employ the
technique of “minimizing directly connected impervious areas” (MDCIA). This project
accomplishes this by:
Drainage Addendum
Registry Ridge Seventh Filing
Fort Collins, CO
7 U14012-DrainageAddendum-Final.doc
• Providing grass buffers throughout the site between impervious areas to
minimize directly connected impervious areas.
• Routing flows through a series of vegetated swales to increase time of
concentration, promote infiltration and provide initial water quality.
• Routing portions of the site through a PLD or permeable pavers to promote
infiltration and provide additional water quality.
Step 2 – Provide Water Quality Capture Volume (WQCV)
The objective of providing WQCV is to reduce the sediment load and other pollutants
that exit the site. For this project WQCV is provided within the regional pond located
south of the site, so no additional WQCV is required. However, the development is
providing a PLD, and therefore, additional WQCV in order to satisfy the LID
requirements.
Step 3 – Stabilize Drainageways
The site is adjacent to an existing drainage channel south of the development. The
project is stabilizing this channel with riprap at the proposed trail crossing of this
channel. The project is also indirectly maintaining the existing stability of the
drainageway by directing the vast majority of onsite flows away from the channel and
to the existing regional pond south of the site. Additionally, this project will pay
stormwater development and stormwater utility fees which the City uses, in part, to
maintain the stability of the City drainageway systems.
Step 4 – Consider Need for Industrial and Commercial BMPs
This step is generally considered for industrial and commercial sites. As this
development is proposing single family dwellings only, no specialized BMPs have been
considered for this project.
Standard Operating Procedures (SOPs)
In order for physical stormwater Best Management Practices (BMPs) to be
effective, proper maintenance is essential. Maintenance includes both routinely
scheduled activities, as well as non-routine repairs that may be required after
large storms, or as a result of other unforeseen problems. Standard Operating
Procedures should clearly identify BMP maintenance responsibility. BMP
maintenance is typically the responsibility of the entity owning the BMP.
Identifying who is responsible for maintenance of BMPs and ensuring that an
adequate budget is allocated for maintenance is critical to the long-term success
of BMPs. Maintenance responsibility may be assigned either publicly or
privately. For this project, the privately owned BMPs shown in Appendix D of
this Addendum are to be maintained by the property owner, homeowner’s
association (HOA), or property manager.
Drainage Addendum
Registry Ridge Seventh Filing
Fort Collins, CO
8 U14012-DrainageAddendum-Final.doc
Erosion Control
Erosion control, both temporary and permanent, is a vital part of any development project.
For this project, as the site disturbance will be over 1-acre, a comprehensive Erosion Control
Report and Stormwater Management Plan have been completed. Refer to the Erosion Control
Report, under separate cover, for additional information.
Conclusions
In conclusion, the drainage system proposed within this Drainage Addendum provides
adequate conveyance of the developed stormwater runoff from the proposed development to
existing discharge locations and drainage systems. In addition, the calculations provided show
that the proposed drainage system does meet the intent and requirements set forth in the
original drainage reports for both the Second and Fourth Filings of Registry Ridge. It should
also be noted that with this addendum and the corresponding design, every attempt has been
made to minimize any negative impacts on the downstream receiving waters. With the
incorporation of the LID techniques, the site will discharge a lower sediment load and less
runoff than the design originally proposed with the Second and Fourth Registry Ridge projects.
We understand that review by the City of Fort Collins is to assure general compliance with
standardized criteria contained in the Fort Collins Stormwater Criteria Manual (FCSCM). This
addendum was prepared in compliance with technical criteria set forth in both the Urban
Drainage and Flood Control District (UDFCD) Urban Storm Drainage Criteria Manual and the
FCSCM.
If you should have any questions or comments as you review this drainage summary, please
feel free to contact us at your convenience.
Sincerely,
United Civil Design Group, LLC
Kevin Brazelton, PE
Engineering Manager
Drainage Addendum
Registry Ridge Seventh Filing
Fort Collins, CO
9 U14012-DrainageAddendum-Final.doc
APPENDICES
APPENDIX A - Hydrology Computations
APPENDIX B - LID Calculations
APPENDIX C - Hydraulic Computations
C.1 – Storm Pipe Calculations
C.2 – Inlet Sizing Calculations
C.3 – Riprap Sizing Calculations
C.4 – Pond Overflow Structure Calculations
C.5 – Street Capacity Calculations
APPENDIX D - Standard Operating Procedures
APPENDIX E – Referenced Material
APPENDIX F - Drainage Exhibit
APPENDIX A
Hydrology Calculations
Registry Ridge Seventh Filing
Fort Collins, CO Runoff Summary
Area Q2
Q100
(acre) (cfs) (cfs)
A1 A1 0.17 49% 0.62 0.78 0.30 1.29
A2 A2 0.43 52% 0.64 0.80 0.79 3.45
A3 A3 0.19 54% 0.65 0.81 0.34 1.50
A4 A4 0.63 18% 0.38 0.48 0.68 2.98
B1 B1 0.14 2% 0.25 0.31 0.10 0.45
B2 B2 0.89 57% 0.67 0.84 1.70 7.42
B3 B3 0.48 44% 0.57 0.72 0.78 3.42
B4 B4 0.76 60% 0.71 0.88 1.36 5.92
1D 1D 0.51 69% 0.76 0.95 1.09 4.77
1E 1E 0.09 48% 0.62 0.77 0.15 0.67
C1 C1 0.62 46% 0.59 0.74 0.75 3.29
C2 C2 0.45 57% 0.67 0.84 0.87 3.78
C3 C3 0.34 59% 0.69 0.86 0.66 2.89
C4 C4 1.14 52% 0.64 0.79 2.07 9.02
C5 C5 0.97 60% 0.69 0.86 1.90 8.31
C6 C6 0.91 33% 0.50 0.62 1.29 5.63
C7 C7 0.09 46% 0.60 0.75 0.11 0.47
C8 C8 1.05 40% 0.55 0.68 1.63 7.13
C9 C9 0.86 36% 0.52 0.65 1.27 5.55
C10 C10 0.71 29% 0.47 0.59 0.95 4.13
C11 C11 0.88 22% 0.41 0.51 1.03 4.47
C12 C12 0.13 2% 0.25 0.31 0.09 0.38
Onsite
Total 11.83 43% 0.56 0.70 18.67 81.49
Existing Basins -Adjacent to North Central Site
Proposed Basins -South Site
Proposed Basins -North Central Site
Proposed Basins -Northeast Site
C C100
Basin Design Point %I 2
Calculations by: KRB
Date: 3/16/2015 C:\United Civil\Dropbox\Projects\U14012 - Liberty Ridge\Drainage\Hydrology\Runoff (Fort Collins).xlsx
Registry Ridge Seventh Filing
Fort Collins, CO Previous Study Site Runoff Coefficients and % Impervious
Roof (1) Concrete(1) Asphalt(1) Permeable
Pavers Landscape(1)
%I = 90% %I = 90% %I =100% %I=22% %I=2%
C = 0.95 C = 0.95 C = 0.95 C = 0.40 C = 0.25
acres sf sf sf sf sf sf C2 C100
Northeast Site
Tract B 1.413 61571 19080 4705 7145 0 30641 47% 0.60 0.75
Northeast Total 1.413 61571 19080 4705 7145 0 30641 47% 0.60 0.75
North Central Site
Tract A 2.272 98960 37855 6230 17295 0 37580 58% 0.68 0.86
North Cemtral Total 2.272 98960 37855 6230 17295 0 37580 58% 0.68 0.86
South Site
Enitre Fourth Filing 8.146 354840 54540 73445 42430 0 184425 45% 0.59 0.73
South Total 8.146 354840 54540 73445 42430 0 184425 45% 0.59 0.73
Notes:
(1) Recommended % Imperviousness Values from USDCM Vol 1 - Ch 5 - Table RO-3. Increased Lawns from 0% to 2% Impervious.
(2) Runoff C2 is based on UDFCD Eq RO-8 per City Amendment to Chapter 5. Runoff C100 is based upon Table RO-12 per City Amendment to Chapter 5.
(3) Basin designations and impervious areas taken from Second Filing report by TST and Fourth Filing report by Northern Engineering.
Basin Design
Pt.
Areas
Composite
Imperviousness
(%I)
Composite Runoff
Total Total Coefficients (2)
Calculations by: KRB
Date: 3/16/2015 C:\United Civil\Dropbox\Projects\U14012 - Liberty Ridge\Drainage\Hydrology\Runoff (Fort Collins).xlsx
Registry Ridge Seventh Filing
Fort Collins, CO Runoff Coefficients and % Impervious
Roof (1) Concrete(1) Asphalt(1) Permeable
Pavers Landscape(1)
%I = 90% %I = 90% %I =100% %I=22% %I=2%
C = 0.95 C = 0.95 C = 0.95 C = 0.40 C = 0.25
acres sf sf sf sf sf sf C2 C100
Proposed Basins -Northeast Site
A1 A1 0.167 7280 2350 1500 0 0 3430 49% 0.62 0.78
A2 A2 0.432 18812 4700 3603 2222 0 8287 52% 0.64 0.80
A3 A3 0.186 8081 1575 1450 1611 0 3446 54% 0.65 0.81
A4 A4 0.629 27398 3126 1995 0 0 22278 18% 0.38 0.48
Northeast Total 1.413 61571 11750 8548 3833 0 37440 37% 0.52 0.66
Proposed Basins -North Central Site
B1 B1 0.144 6281 0 0 0 0 6281 2% 0.25 0.31
B2 B2 0.886 38591 8813 7500 7052 0 15227 57% 0.67 0.84
B3 B3 0.480 20910 2350 3645 3655 0 11260 44% 0.57 0.72
B4 B4 0.762 33178 11750 8681 1225 0 11522 60% 0.71 0.88
North Cemtral Total 2.272 98960 22913 19826 11932 0 44290 52% 0.64 0.80
Existing Basins -Adjacent to North Central Site (3)
1D(3) 1D(3) 0.507 22065 7930 1433 6607 0 6095 69% 0.76 0.95
1E(3) 1E(3) 0.088 3822 1197 814 0 0 1811 48% 0.62 0.77
Proposed Basins -South Site
C1 C1 0.619 26985 5288 5342 2599 0 13757 46% 0.59 0.74
C2 C2 0.454 19774 4700 3551 3613 0 7910 57% 0.67 0.84
C3 C3 0.339 14768 3525 2688 2966 0 5589 59% 0.69 0.86
Composite Runoff
Basin Coefficients (2)
Areas
Composite
Imperviousness
(%I)
Design Total Total
Pt.
Calculations by: KRB
Date: 3/16/2015 C:\United Civil\Dropbox\Projects\U14012 - Liberty Ridge\Drainage\Hydrology\Runoff (Fort Collins).xlsx
Registry Ridge Seventh Filing
Fort Collins, CO Runoff Coefficients and % Impervious
C4 C4 1.142 49749 10575 7188 9613 0 22373 52% 0.64 0.79
C5 C5 0.971 42285 7638 8629 10214 0 15805 60% 0.69 0.86
C6 C6 0.908 39561 8225 5801 0 0 25535 33% 0.50 0.62
C7 C7 0.088 3831 1175 750 0 0 1906 46% 0.60 0.75
C8 C8 1.047 45609 9988 7515 0 8762 19345 40% 0.55 0.68
C9 C9 0.856 37286 8813 5625 0 0 22849 36% 0.52 0.65
C10 C10 0.709 30884 5875 3750 0 0 21259 29% 0.47 0.59
C11 C11 0.882 38424 5288 3375 0 0 29762 22% 0.41 0.51
C12 C12 0.130 5684 0 0 0 0 5684 2% 0.25 0.31
South Total 8.146 354840 71088 54214 29005 8762 191772 41% 0.55 0.69
Onsite Total 11.831 515371 105750 82588 44770 8762 273501 43% 0.56 0.70
Notes:
(1) Recommended % Imperviousness Values from USDCM Vol 1 - Ch 5 - Table RO-3. Increased Lawns from 0% to 2% Impervious.
(2) Runoff C2 is based on UDFCD Eq RO-8 per City Amendment to Chapter 5. Runoff C100 is based upon Table RO-12 per City Amendment to Chapter 5.
(3) Existing basins adjacent to North Central site that drain through the proposed site. Basin designations and impervious areas taken from Second Filing report by TST.
Calculations by: KRB
Date: 3/16/2015 C:\United Civil\Dropbox\Projects\U14012 - Liberty Ridge\Drainage\Hydrology\Runoff (Fort Collins).xlsx
Registry Ridge Seventh Filing
Fort Collins, CO Time of Concentration
Area Length Slope ti
(2) Length Slope
Velocity
(3) tt
(4) Check
tc?
Total
Length tc
(5)
acres ft % min ft % fps min min u =
urban
ft min min
Proposed Basins -Northeast Site
A1 A1 0.17 Roof 0.73 20 2 2.4 85 2 20 2.8 0.5 2.9 u 105 11 5
A2 A2 0.43 Roof 0.73 20 2 2.4 95 2 20 2.8 0.6 2.9 u 115 11 5
A3 A3 0.19 Roof 0.73 20 2 2.4 50 2 20 2.8 0.3 2.7 u 70 10 5
A4 A4 0.63 Roof 0.73 40 2 3.4 105 5.5 20 4.7 0.4 3.7 u 145 11 5
Proposed Basins -North Central Site
B1 B1 0.14 Roof 0.73 17 1.6 2.4 56 0.6 20 1.5 0.6 3.0 u 73 10 5
B2 B2 0.89 Roof 0.73 20 2 2.4 240 1.41 20 2.4 1.7 4.1 u 260 11 5
B3 B3 0.48 Roof 0.73 30 2 2.9 205 1.82 20 2.7 1.3 4.2 u 235 11 5
B4 B4 0.76 Roof 0.73 20 2 2.4 560 0.94 20 1.9 4.8 7.2 u 580 13 7
Existing Basins -Adjacent to North Central Site
1D 1D 0.51 Roof 0.73 20 2 2.4 170 1.5 20 2.4 1.2 3.5 u 190 11 5
1E 1E 0.09 Roof 0.73 20 2 2.4 25 2 20 2.8 0.1 2.5 u 45 10 5
Proposed Basins -South Site
C1 C1 0.62 Lawn 0.09 46 1.76 10.2 343 0.57 20 1.5 3.8 14.0 u 389 12 12
C2 C2 0.45 Roof 0.73 20 2 2.4 240 1 20 2.0 2.0 4.4 u 260 11 5
C3 C3 0.34 Roof 0.73 20 2 2.4 202 1.05 20 2.0 1.6 4.0 u 222 11 5
C4 C4 1.14 Roof 0.73 20 2 2.4 295 1.5 20 2.4 2.0 4.4 u 315 12 5
C5 C5 0.97 Roof 0.73 20 2 2.4 400 1.16 20 2.2 3.1 5.5 u 420 12 5
C6 C6 0.91 Roof 0.73 20 2 2.4 295 1.34 20 2.3 2.1 4.5 u 315 12 5
C7 C7 0.09 Lawn 0.09 85 1.45 14.8 223 1.54 20 2.5 1.5 16.3 u 308 12 12
C8 C8 1.05 Roof 0.73 20 2 2.4 350 1.83 20 2.7 2.2 4.5 u 370 12 5
C9 C9 0.86 Roof 0.73 20 2 2.4 75 4.81 20 4.4 0.3 2.7 u 95 11 5
C10 C10 0.71 Roof 0.73 20 2 2.4 125 4.1 20 4.0 0.5 2.9 u 145 11 5
C11 C11 0.88 Roof 0.73 20 2 2.4 345 3.2 20 3.6 1.6 4.0 u 365 12 5
C12 C12 0.13 Roof 0.73 40 0.5 5.3 215 2.6 20 3.2 1.1 6.4 u 255 11 6
Notes:
(1)
C5 based initial ground type and Table RO-5
(4)
tt=L/(V*60 sec/min)
(2)
ti = [1.8(1.1-C
5)L
1/2
]/S
1/3
, S= slope in %, L=length of overland flow (400' max)
(5)
tc check (for urban or developed areas only) = total length/180 + 10
(3)
V=CvS
0.5
, S=watercourse slope in ft/ft, UDFCD Equation RO-4
(6)
min tc = 5 min
Registry Ridge Seventh Filing
Fort Collins, CO Rational Method Peak Runoff
Final
tc
(6) I2 I100 Q2 Q100
acres min in/hr in/hr cfs cfs
Proposed Basins -Northeast Site
A1 A1 0.167 5 0.62 0.78 2.85 9.95 0.295 1.289
A2 A2 0.432 5 0.64 0.80 2.85 9.95 0.790 3.446
A3 A3 0.186 5 0.65 0.81 2.85 9.95 0.344 1.503
A4 A4 0.629 5 0.38 0.48 2.85 9.95 0.683 2.979
Proposed Basins -North Central Site
B1 B1 0.144 5 0.25 0.31 2.85 9.95 0.103 0.448
B2 B2 0.886 5 0.67 0.84 2.85 9.95 1.701 7.424
B3 B3 0.480 5 0.57 0.72 2.85 9.95 0.784 3.421
B4 B4 0.762 7 0.71 0.88 2.52 8.80 1.357 5.923
Existing Basins -Adjacent to North Central Site
1D 1D 0.507 5 0.76 0.95 2.85 9.95 1.092 4.767
1E 1E 0.088 5 0.62 0.77 2.85 9.95 0.155 0.675
Proposed Basins -South Site
C1 C1 0.619 12 0.59 0.74 2.05 7.16 0.753 3.289
C2 C2 0.454 5 0.67 0.84 2.85 9.95 0.867 3.783
C3 C3 0.339 5 0.69 0.86 2.85 9.95 0.662 2.889
C4 C4 1.142 5 0.64 0.79 2.85 9.95 2.068 9.023
C5 C5 0.971 5 0.69 0.86 2.85 9.95 1.904 8.311
C6 C6 0.908 5 0.50 0.62 2.85 9.95 1.289 5.627
C7 C7 0.088 12 0.60 0.75 2.05 7.16 0.108 0.474
C8 C8 1.047 5 0.55 0.68 2.85 9.95 1.634 7.129
C9 C9 0.856 5 0.52 0.65 2.85 9.95 1.271 5.547
C10 C10 0.709 5 0.47 0.59 2.85 9.95 0.946 4.128
C11 C11 0.882 5 0.41 0.51 2.85 9.95 1.025 4.474
C12 C12 0.130 6 0.25 0.31 2.67 9.31 0.087 0.380
Onsite Total 11.831 18.672 81.488
Design
Pt. Peak Discharge
Basin Area Runoff Coefficients Rainfall Intensity
C2 C100
Calculations by: KRB
Date: 3/16/2015 C:\United Civil\Dropbox\Projects\U14012 - Liberty Ridge\Drainage\Hydrology\Runoff (Fort Collins).xlsx
APPENDIX B
LID Calculations
Sheet 1 of 2
Designer:
Company:
Date:
Project:
Location:
1. Basin Storage Volume
A) Effective Imperviousness of Tributary Area, Ia Ia = 50.7 %
(100% if all paved and roofed areas upstream of rain garden)
B) Tributary Area's Imperviousness Ratio (i = Ia/100) i = 0.507
C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time WQCV = 0.17 watershed inches
(WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i)
D) Contributing Watershed Area (including rain garden area) Area = 166,138 sq ft
E) Water Quality Capture Volume (WQCV) Design Volume VWQCV = 2,306 cu ft
Vol = (WQCV / 12) * Area
F) For Watersheds Outside of the Denver Region, Depth of d6 = in
Average Runoff Producing Storm
G) For Watersheds Outside of the Denver Region, VWQCVOTHER = cu ft
Water Quality Capture Volume (WQCV) Design Volume
H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCVUSER = cu ft
(Only if a different WQCV Design Volume is desired)
2. Basin Geometry
A) WQCV Depth (12-inch maximum) DWQCV = 8 in
B) Rain Garden Side Slopes (Z = 4 min., horiz. dist per unit vertical) Z = 4.00 ft / ft
(Use "0" if rain garden has vertical walls)
C) Mimimum Flat Surface Area AMin = 1537 sq ft
D) Actual Flat Surface Area AActual = 4703 sq ft
E) Area at Design Depth (Top Surface Area) ATop = 6589 sq ft
F) Rain Garden Total Volume VT= 3,792 cu ft
(VT= ((ATop + AActual) / 2) * Depth)
3. Growing Media
4. Underdrain System
A) Are underdrains provided?
B) Underdrain system orifice diameter for 12 hour drain time
i) Distance From Lowest Elevation of the Storage y = ft
Volume to the Center of the Orifice
ii) Volume to Drain in 12 Hours Vol12 = N/A cu ft
iii) Orifice Diameter, 3/8" Minimum DO = N/A in
Design Procedure Form: Rain Garden (RG)
KRB
United Civil
November 12, 2014
Registry Ridge Seventh Filing
Fort Collins
Choose One
Choose One
18" Rain Garden Growing Media
Other (Explain):
YES
NO
UD-BMP_v3.03.xlsm, RG 11/12/2014, 11:27 AM
Sheet 2 of 2
Designer:
Company:
Date:
Project:
Location:
5. Impermeable Geomembrane Liner and Geotextile Separator Fabric
A) Is an impermeable liner provided due to proximity
of structures or groundwater contamination?
6. Inlet / Outlet Control
A) Inlet Control
7. Vegetation
8. Irrigation
A) Will the rain garden be irrigated?
Notes:
Design Procedure Form: Rain Garden (RG)
KRB
United Civil
November 12, 2014
Registry Ridge Seventh Filing
Fort Collins
Choose One
Choose One
Choose One
Sheet Flow- No Energy Dissipation Required
Concentrated Flow- Energy Dissipation Provided
Plantings
Seed (Plan for frequent weed control)
Sand Grown or Other High Infiltration Sod
Choose One
YES
NO
YES
NO
UD-BMP_v3.03.xlsm, RG 11/12/2014, 11:27 AM
STAGE STORAGE TABLE - East Side of PLD
ELEV
AREA
(sq. ft.)
DEPT
H
(ft)
AVG END
INC. VOL.
(cu. ft.)
AVG END
TOTAL VOL.
(cu. ft.)
CONIC
INC. VOL.
(cu. ft.)
CONIC
TOTAL VOL.
(cu. ft.)
5,063.200 973.07 N/A N/A 0.00 N/A 0.00
5,063.300 1,970.22 0.100 147.16 147.16 144.26 144.26
5,063.400 2,727.37 0.100 234.88 382.04 233.86 378.12
5,063.500 2,819.08 0.100 277.32 659.37 277.31 655.43
5,063.600 2,911.84 0.100 286.55 945.91 286.53 941.96
5,063.700 3,005.71 0.100 295.88 1241.79 295.86 1237.83
5,063.800 3,100.83 0.100 305.33 1547.12 305.31 1543.14
5,063.900 3,197.33 0.100 314.91 1862.02 314.90 1858.04
5,064.000 3,295.23 0.100 324.63 2186.65 324.62 2182.65
5,064.100 3,394.51 0.100 334.49 2521.14 334.47 2517.13
STAGE STORAGE TABLE - West Side of PLD
ELEV
AREA
(sq. ft.)
DEPTH
(ft)
AVG END
INC. VOL.
(cu. ft.)
AVG END
TOTAL VOL.
(cu. ft.)
CONIC
INC. VOL.
(cu. ft.)
CONIC
TOTAL VOL.
(cu. ft.)
5,063.200 491.08 N/A N/A 0.00 N/A 0.00
5,063.300 1,072.05 0.100 78.16 78.16 76.29 76.29
5,063.400 1,617.81 0.100 134.49 212.65 133.56 209.85
5,063.500 2,069.78 0.100 184.38 397.03 183.92 393.77
5,063.600 2,358.28 0.100 221.40 618.43 221.25 615.01
5,063.700 2,454.79 0.100 240.65 859.09 240.64 855.65
5,063.800 2,546.72 0.100 250.08 1109.16 250.06 1105.71
5,063.900 2,639.81 0.100 259.33 1368.49 259.31 1365.03
5,064.000 2,734.32 0.100 268.71 1637.20 268.69 1633.72
5,064.100 2,830.13 0.100 278.22 1915.42 278.21 1911.93
APPENDIX C
Hydraulic Calculations
Culvert Report
Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc. Monday, Mar 16 2015
Storm Line 4 (Dual Box Culverts)
Invert Elev Dn (ft) = 65.18
Pipe Length (ft) = 33.97
Slope (%) = 1.00
Invert Elev Up (ft) = 65.52
Rise (in) = 24.0
Shape = Box
Span (in) = 72.0
No. Barrels = 2
n-Value = 0.013
Culvert Type = Flared Wingwalls
Culvert Entrance = 30D to 75D wingwall flares
Coeff. K,M,c,Y,k = 0.026, 1, 0.0347, 0.81, 0.4
Embankment
Top Elevation (ft) = 69.00
Top Width (ft) = 10.00
Crest Width (ft) = 40.00
Calculations
Qmin (cfs) = 160.00
Qmax (cfs) = 160.00
Tailwater Elev (ft) = (dc+D)/2
Highlighted
Qtotal (cfs) = 160.00
Qpipe (cfs) = 160.00
Qovertop (cfs) = 0.00
Veloc Dn (ft/s) = 7.08
Veloc Up (ft/s) = 7.55
HGL Dn (ft) = 67.06
HGL Up (ft) = 67.29
Hw Elev (ft) = 68.67
Hw/D (ft) = 1.58
Flow Regime = Inlet Control
Project =
Inlet ID =
Design Information (Input) MINOR MAJOR
Type of Inlet Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from 'Q-Allow') alocal
= 4.25 4.25 inches
Number of Unit Inlets (Grate or Curb Opening) No = 1 1
Water Depth at Flowline (outside of local depression) Ponding Depth = 4.8 7.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo
(G) = N/A N/A feet
Width of a Unit Grate Wo
= N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90) Aratio
= N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70) Cf
(G) = N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60) Cw
(G) = N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80) Co
(G) = N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo
(C) = 5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert
= 6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat
= 6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5) Theta = 63.40 63.40 degrees
Side Width for DepressionPan (typically the gutter width of 2 feet) Wp
= 1.42 1.42 feet
Clogging Factor for a Single Curb Opening (typical value 0.10) Cf
(C) = 0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7) Cw
(C) = 3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70) Co
(C) = 0.67 0.67
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition) Qa
= 3.6 8.4 cfs
Inlet Capacity IS GOOD for Minor and Major Storms (>Q PEAK) Q PEAK REQUIRED
= 1.9 8.3 cfs
INLET IN A SUMP OR SAG LOCATION
Registry Ridge Seventh Filing
Inlets 2-2, 3-1, 6-1
CDOT Type R Curb Opening
H-Vert
H-Curb
W
Lo (C)
Lo (G)
Wo
WP
Override Depths
UD-Inlet_v3.14 (Inlet 2-2,3-1,6-1).xlsm, Inlet In Sump 3/16/2015, 1:05 PM
Project =
Inlet ID =
Design Information (Input) MINOR MAJOR
Type of Inlet Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from 'Q-Allow') alocal
= 4.25 4.25 inches
Number of Unit Inlets (Grate or Curb Opening) No = 2 2
Water Depth at Flowline (outside of local depression) Ponding Depth = 4.8 7.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo
(G) = N/A N/A feet
Width of a Unit Grate Wo
= N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90) Aratio
= N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70) Cf
(G) = N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60) Cw
(G) = N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80) Co
(G) = N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo
(C) = 5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert
= 6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat
= 6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5) Theta = 63.40 63.40 degrees
Side Width for DepressionPan (typically the gutter width of 2 feet) Wp
= 1.42 1.42 feet
Clogging Factor for a Single Curb Opening (typical value 0.10) Cf
(C) = 0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7) Cw
(C) = 3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70) Co
(C) = 0.67 0.67
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition) Qa
= 6.5 17.2 cfs
Inlet Capacity IS GOOD for Minor and Major Storms (>Q PEAK) Q PEAK REQUIRED
= 3.6 15.7 cfs
INLET IN A SUMP OR SAG LOCATION
Registry Ridge Seventh Filing
Inlet 2-3
CDOT Type R Curb Opening
H-Vert
H-Curb
W
Lo (C)
Lo (G)
Wo
WP
Override Depths
UD-Inlet_v3.14 (Inlet 2-3).xlsm, Inlet In Sump 3/16/2015, 1:06 PM
Registry Ridge Seventh Filing
Fort Collins, CO Area Inlet Capacity
INLET ID: Inlet 5-1
Governing Equations:
Inlet capacity equation at low flows (weir calculation):
Where:
P = 2(L + W)
H = depth of water above the flowline
Inlet capacity equation at higher flows (orifice calculation):
Where:
A = open area of the inlet grate
H = depth of water above the centroid of the cross-sectional area (A)
Input Parameters:
Grate: 15" Nyloplast (1599CGD)
Wier Perimeter: 3.93
Open Area of Grate (ft2): 0.80 Q2 = 0.25 cfs
Flowline Elevation (ft): 5076.16 Q100 = 1.12 cfs
Allowable Capacity: 50%
Depth vs. Flow:
Depth Above Inlet
(ft)
Elevation
(ft)
Shallow
Weir Flow
(cfs)
Orifice
Flow
(cfs)
Actual
Flow
(cfs)
0.00 5076.16 0.00 0.00 0.00
0.10 5076.26 0.19 0.68 0.19
0.20 5076.36 0.53 0.96 0.53
0.30 5076.46 0.97 1.18 0.97
0.33 5076.49 1.12 1.24 1.12 Q100
0.50 5076.66 2.08 1.52 1.52
0.60 5076.76 2.74 1.67 1.67
0.70 5076.86 3.45 1.80 1.80
0.80 5076.96 4.22 1.93 1.93
0.90 5077.06 5.03 2.04 2.04
1.00 5077.16 5.90 2.16 2.16
Q = 3 . 0 P H 1 . 5
Q = 0 .67A ( 2 gH ) 0 . 5
Calculations by: KRB
Date: 3/16/2015 C:\United Civil\Dropbox\Projects\U14012 - Liberty Ridge\Drainage\Hydraulics\Inlets\Area Inlets.xlsx
Registry Ridge Seventh Filing
Fort Collins, CO
Riprap Sizing at Pipe Outlets
Circular
D or Da,
Pipe
Diameter
(ft)
H or Ha,
Culvert
Height
(ft)
W,
Culvert
Width
(ft)
Yt/D Q/D1.5 Q/D2.5 Yt/H Q/WH0.5
Storm Line 1 Outlet 29.63 2.00 1.86 0.93 10.48 5.24 N/A N/A 5.00 5.24 5.93 5.93 Type L 10.00 5.00 1.5
Storm Line 2 Outlet 24.00 2.00 1.73 0.87 8.49 4.24 N/A N/A 6.25 4.24 4.80 4.84 Type L 5.00 5.00 1.5
Storm Line 3 Outlet 5.66 1.50 1.28 0.85 3.08 2.05 N/A N/A 6.60 2.05 1.13 -4.06 Type L 5.00 5.00 1.5
Storm Line 4 Outlet 160.00 2.00 12.00 1.88 N/A N/A N/A 0.94 9.43 6.25 4.71 22.60 75.13 Type L 20.00 12.00 1.5
CALCULATE
Yt,
Tailwater
Depth
(ft)
Riprap
Type
(From
Figure
MD-21 or
MD-22)
OUTPUT
Spec
Min. Length
of
Riprap
(ft)
Box Culvert
Pipe Designation Design
Discharge
(cfs)
L=
1/(2tanq)*
[At/Yt)-W]
(ft)
INPUT
Urban Drainage
Culvert Parameters pg MD-107
At=Q/V
(ft)
Expansion
Factor
1/(2tanq)
(From
Figure
MD-23 or
MD-24)
Circular
Pipe
Registry Ridge Seventh Filing
Fort Collins, CO
Weir Capacity
Outlet Structure ID: PLD 100-Year Overflow Structure
Governing Equation:
The trapezoidal weir is a broad-crested weir governed by the following equation:
* where Q = discharge (cfs)
* where C w = weir coefficient
* where L = crest length (ft)
* where H = head on weir (ft)
* where b = 1.5
For 4:1 side slopes, q = 151.9276° so that tan (q/2) = 4
Input Parameters:
Top of Weir Elevation (ft) = 5064.10
Crest Elevation (ft) = 5065.10
Length of Weir (ft) = 11.67 Type C Inlet
Weir Coefficient = 2.60
Depth vs. Flow:
Depth Above Crest (ft) Elevation (ft)
0.00 5064.10
0.10 5064.20
0.20 5064.30
0.30 5064.40
0.40 5064.50
0.50 5064.60
0.60 5064.70
0.70 5064.80
0.80 5064.90
0.85 5064.95
0.95 5065.05
12
16
21
26
29.6
36
Outlet Structure Weir Discharge (cfs)
0
1
3
5
9
b
Q C w L H H
= +
2
0 . 8 tan
θ
100-year flowrate
Calculations by: XXX
Channel Report
Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc. Tuesday, Mar 3 2015
Sidewalk Culverts
Rectangular
Bottom Width (ft) = 2.00
Total Depth (ft) = 0.50
Invert Elev (ft) = 100.00
Slope (%) = 2.00
N-Value = 0.013
Calculations
Compute by: Known Depth
Known Depth (ft) = 0.50
Highlighted
Depth (ft) = 0.50
Q (cfs) = 7.769
Area (sqft) = 1.00
Velocity (ft/s) = 7.77
Wetted Perim (ft) = 3.00
Crit Depth, Yc (ft) = 0.50
Top Width (ft) = 2.00
EGL (ft) = 1.44
0 .5 1 1.5 2 2.5 3
Elev (ft) Section Depth (ft)
99.75 -0.25
100.00 0.00
100.25 0.25
100.50 0.50
100.75 0.75
101.00 1.00
Reach (ft)
Channel Report
Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc. Tuesday, Mar 3 2015
Hornet Drive Minor Event Street Section Capacity
User-defined
Invert Elev (ft) = 99.61
Slope (%) = 0.60
N-Value = 0.013
Calculations
Compute by: Known Depth
Known Depth (ft) = 0.39
(Sta, El, n)-(Sta, El, n)...
( 0.00, 100.20) -(10.08, 100.00, 0.013) -(11.50, 99.61, 0.013) -(12.67, 99.72, 0.013) -(26.50, 100.00, 0.013) -(40.33, 99.72, 0.013) -(41.50, 99.61, 0.013)
-(42.92, 100.00, 0.013) -(53.00, 100.20, 0.013)
Highlighted
Depth (ft) = 0.39
Q (cfs) = 13.51
Area (sqft) = 5.21
Velocity (ft/s) = 2.59
Wetted Perim (ft) = 32.96
Crit Depth, Yc (ft) = 0.41
Top Width (ft) = 32.84
EGL (ft) = 0.49
-5 0 5 10 15 20 25 30 35 40 45 50 55 60
Elev (ft) Section Depth (ft)
99.00 -0.61
99.50 -0.11
100.00 0.39
100.50 0.89
101.00 1.39
Sta (ft)
Channel Report
Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc. Tuesday, Mar 3 2015
Hornet Drive Major Event Street Section Capacity
User-defined
Invert Elev (ft) = 99.61
Slope (%) = 0.60
N-Value = 0.013
Calculations
Compute by: Known Q
Known Q (cfs) = 24.00
(Sta, El, n)-(Sta, El, n)...
( 0.00, 100.21) -(10.08, 100.00, 0.013) -(11.50, 99.61, 0.013) -(12.67, 99.72, 0.013) -(26.50, 100.00, 0.013) -(40.33, 99.72, 0.013) -(41.50, 99.61, 0.013)
-(42.92, 100.00, 0.013) -(53.00, 100.21, 0.013)
Highlighted
Depth (ft) = 0.47
Q (cfs) = 24.00
Area (sqft) = 8.14
Velocity (ft/s) = 2.95
Wetted Perim (ft) = 40.50
Crit Depth, Yc (ft) = 0.50
Top Width (ft) = 40.38
EGL (ft) = 0.61
-5 0 5 10 15 20 25 30 35 40 45 50 55 60
Elev (ft) Section Depth (ft)
99.00 -0.61
99.50 -0.11
100.00 0.39
100.50 0.89
101.00 1.39
Sta (ft)
APPENDIX D
Standard Operating Procedures
STANDARD OPERATING PROCEDURES (SOPs)
A. Purpose
Proper maintenance is an essential process for effective physical stormwater Best
Management Practices (BMPs). Maintenance includes both routinely scheduled activities
as well as non-routine repairs that may be required after large storms, or as a result of
other unforeseen problems. Standard Operating Procedures should clearly identify BMP
maintenance responsibility. BMP maintenance is typically the responsibility of the entity
owning the BMP.
Long term success of BMPs provides two critical components: Identification of who is
responsible for maintenance of BMPs, and the surety that an adequate budget is
allocated for maintenance. Maintenance responsibility may be assigned either publicly or
privately. For this project, the privately owned BMPs shown below in Section B are to be
maintained by the property owner or property manager.
B. Site-Specific SOPs
The following stormwater facilities contained within Registry Ridge Seventh Filing are
subject to the following SOP requirements:
- Bioretention
- Permeable Interlocking Concrete Pavement
- Vegetated Swales
The location of said facilities can be found on the Utility Plans for Registry Ridge Seventh
Filing. Inspection and maintenance procedures and frequencies, specific maintenance
requirements and activities, as well as BMP-specific constraints and considerations shall
follow the guidelines outlined in Volume 3 of the Urban Drainage and Flood Control
District (UDFCD) Urban Storm Drainage Criteria Manual for Bioretention, Pervious
Pavement and Vegetated Swales.
SOP Maintenance Summary Table
Stormwater Facility /
BMP
Ownership /
Responsibility Maintenance Reference
Bioretention Pond Private
Follow applicable guidelines for
Bioretention within UDFCD.
Permeable Pavement Private
Follow applicable guidelines for
Permeable Pavement within UDFCD.
Vegetative Swales Private
Follow applicable guidelines for
Vegitative Swales within UDFCD.
The complete UDFCD BMP maintenance references listed above can be found in Chapter
6 of Volume 3. Applicable excerpts for "Routine" maintenance requirements for the BMP
can be found on the following page. Additionally, it is strongly recommended that the
Guidelines for Use of Pesticides, Herbicides and Fertilizers (UDFCD Fact Sheet S-8), and
the Landscape Maintenance procedures (UDFCD Fact Sheet S-9) be followed, not just
within the drainage facilities themselves, but for the entire development.
Bioretention Routine Maintenance Table (Summary from Chapter 6 of UDFCD)
Required Action Maintenance Objective Frequency of Action
Lawn mowing and
vegetative care
Occasional mowing of grasses and weed
removal to limit unwanted vegetation.
Maintain irrigated turf grass as 2 to 4 inches
tall and nonirrigated native turf grasses at 4
to 6 inches.
Routine – Depending on aesthetic
requirements.
Debris and Litter
removal
Remove debris and litter from detention area
to minimize clogging of the sand media.
Remove debris and litter from the pond area
and outlet orifice plate to minimize clogging.
Remove debris and litter from curb channel
and sidewalk chase outlets adjacent to pond
if applicable to minimize clogging.
Routine – Including just before annual
storm seasons (that is, April and May),
end of storm season after leaves have
fallen, and following significant rainfall
events.
Sand Media and
Landscaping
removal and
replacement
The bioretention sand media and landscaping
layer will clog with time. This layer will need
to be removed and replaced, along with all
turf and other vegetation growing on the
surface, to rehabilitate infiltration rates.
Every 5 to 10 years, depending on
infiltration rates needed to drain the
WQCV in 12-hours or less. May need to
be performed more frequently if
exfiltration rates are too low to achieve
this goal.
Inspections
Inspect detention area to determine if the
sand media is allowing acceptable infiltration.
If standing water persists for more than 24
hours after storm runoff has ceased, clogging
should be further investigated and remedied.
Routine – Bi-annual inspection of
hydraulic performance.
Permeable Interlocking Concrete Paver Routine Maintenance Table (Summary from Chapter 6 of UDFCD)
Required Action Maintenance Objective Frequency of Action
Debris Removal,
Sweeping and
Vacuuming
Use a regenerative air or vacuum sweeper to
maintain infiltration rates. This should be
done on a warm day. Do not use water with
the sweeper. After vacuuming, replace infill
aggregate as needed.
After any significant site work (e.g.,
landscaping) and approximately twice per
Vegetative Swale Routine Maintenance Table (Summary from Chapter 6 of UDFCD)
Required
Action Maintenance Objective Frequency of Action
Lawn mowing
and Lawn care
Maintain irrigated grass at 2 to 4 inches tall
and nonirrigated native grass at 6 to 8 inches
tall. Collect cuttings and dispose of them
offsite or use a mulching mower.
Routine – As needed.
Debris and Litter
removal
Keep the area clean for aesthetic reasons,
which also reduces floatables being flushed
downstream.
Routine – As needed by
inspection, but no less than two
times per year.
Sediment
removal
Remove accumulated sediment near culverts
and in channels to maintain flow capacity.
Replace the grass areas damaged in the
process.
Routine – As needed by
inspection. Estimate the need to
remove sediment from 3 to 10
percent of total length per year,
as determined by annual
inspection.
Inspections
Check the grass for uniformity of cover,
sediment accumulation in the swale, and near
culverts.
Routine – Annual inspection is
suggested.
APPENDIX E
Referenced Material
This unofficial copy was downloaded on Oct-27-2014 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com
For additional information or an official copy, please contact City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80524 USA
This unofficial copy was downloaded on Oct-27-2014 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com
For additional information or an official copy, please contact City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80524 USA
This unofficial copy was downloaded on Oct-27-2014 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com
For additional information or an official copy, please contact City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80524 USA
This unofficial copy was downloaded on Oct-27-2014 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com
For additional information or an official copy, please contact City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80524 USA
This unofficial copy was downloaded on Oct-27-2014 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com
For additional information or an official copy, please contact City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80524 USA
This unofficial copy was downloaded on Oct-27-2014 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com
For additional information or an official copy, please contact City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80524 USA
This unofficial copy was downloaded on Oct-27-2014 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com
For additional information or an official copy, please contact City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80524 USA
This unofficial copy was downloaded on Oct-27-2014 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com
For additional information or an official copy, please contact City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80524 USA
This unofficial copy was downloaded on Oct-21-2014 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com
For additional information or an official copy, please contact City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80524 USA
This unofficial copy was downloaded on Oct-21-2014 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com
For additional information or an official copy, please contact City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80524 USA
This unofficial copy was downloaded on Oct-21-2014 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com
For additional information or an official copy, please contact City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80524 USA
This unofficial copy was downloaded on Oct-21-2014 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com
For additional information or an official copy, please contact City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80524 USA
APPENDIX F
Drainage Exhibit
A4
A1
C8 C3
C4
C5
C6
C9
S8
C7
C11
C10
C12
POROUS LANDSCAPE
DETENTION
POROUS LANDSCAPE
DETENTION
HORNET DRIVE
ENTERPRISE DRIVE
CABOT COURT
NIMITZ DRIVE
(PRIVATE DRIVE)
SAIPAN COURT
PROPOSED
STORM INLET
PROPOSED STORM
DRAIN LINE 3
PROPOSED STORM
DRAIN LINE 6
PROPOSED
STORM INLETS
PROPOSED
STORM INLET
CURB CUT AND
SIDEWALK CHASE
CURB CUT AND
SIDEWALK CHASE
CURB CUT AND
SIDEWALK CHASE
PROPOSED STORM
DRAIN LINE 2
PROPOSED POND
OVERFLOW STRUCTURE
CURB CUT AND
SIDEWALK CHASE
PERMEABLE PAVERS
WITH UNDERDRAIN
CITY HIGH RISK
FLOODWAY
PROPOSED STORM
DRAIN LINE 5
PROPOSED STORM
DRAIN LINE 1
KITTY HAWK COURT
(PRIVATE DRIVE)
(PRIVATE DRIVE) CABOT COURT (PRIVATE DRIVE)
PROPOSED STORM
DRAIN LINE 4
PREPARED FOR: DATE SUBMITTED:
The engineer preparing these plans will not be responsible
for, or liable for, unauthorized changes to or uses of these
plans. All changes to the plans must be in writing and
must be approved by the preparer of these plans.
CAUTION
BQ, LLC. 3/18/2015
U14012
PRELIMINARY
PLANS
NOT FOR CONSTRUCTION
1501 Academy Ct.
Ste. 203
Fort Collins, CO 80524
(970) 530-4044
www.unitedcivil.com
Civil Engineering &
Consulting
REGISTRY RIDGE SEVENTH FILING
DRAINAGE PLAN
C800
N/A
CHECKED BY: 60'
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
APPROVED:
00 60' 120'
SCALE: 1" = 60'
30'
1. EXISTING UNDERGROUND AND
OVERHEAD PUBLIC AND PRIVATE
UTILITIES AS SHOWN ARE INDICATED
ACCORDING TO THE BEST INFORMATION
AVAILABLE TO THE ENGINEER.
2. VEGETATIVE SWALES, PERMEABLE
PAVERS AND THE POROUS LANDSCAPE
DETENTION SHALL BE MAINTAINED BY
THE PROPERTY OWNER OR HOA AND
FOLLOW APPLICABLE STANDARD
OPERATING PROCEDURES AS SHOWN IN
DRAINAGE REPORT FOR REGISTRY
RIDGE SEVENTH FILING.
LEGEND
NOTES
D-101
BASIN DESIGNATION
BASIN AREA (ACRE)
2 - YR RUNOFF COEFF.
100 - YR RUNOFF COEFF.
BASIN BOUNDARY
DESIGN POINT
FLOW DIRECTION
DRAINAGE SUMMARY
Basin Design
Point
Area
%I C2 C100
Q2 Q100
(acre) (cfs) (cfs)
Proposed Basins -Northeast Site
A1 A1 0.17 49% 0.62 0.78 0.30 1.29
A2 A2 0.43 52% 0.64 0.80 0.79 3.45
A3 A3 0.19 54% 0.65 0.81 0.34 1.50
A4 A4 0.63 18% 0.38 0.48 0.68 2.98
Proposed Basins -North Central Site
B1 B1 0.14 2% 0.25 0.31 0.10 0.45
B2 B2 0.89 57% 0.67 0.84 1.70 7.42
B3 B3 0.48 44% 0.57 0.72 0.78 3.42
B4 B4 0.76 60% 0.71 0.88 1.36 5.92
Existing Basins -Adjacent to North Central Site
1D 1D 0.51 69% 0.76 0.95 1.09 4.77
1E 1E 0.09 48% 0.62 0.77 0.15 0.67
Proposed Basins -South Site
C1 C1 0.62 46% 0.59 0.74 0.75 3.29
C2 C2 0.45 57% 0.67 0.84 0.87 3.78
C3 C3 0.34 59% 0.69 0.86 0.66 2.89
C4 C4 1.14 52% 0.64 0.79 2.07 9.02
C5 C5 0.97 60% 0.69 0.86 1.90 8.31
C6 C6 0.91 33% 0.50 0.62 1.29 5.63
C7 C7 0.09 46% 0.60 0.75 0.11 0.47
C8 C8 1.05 40% 0.55 0.68 1.63 7.13
C9 C9 0.86 36% 0.52 0.65 1.27 5.55
C10 C10 0.71 29% 0.47 0.59 0.95 4.13
C11 C11 0.88 22% 0.41 0.51 1.03 4.47
C12 C12 0.13 2% 0.25 0.31 0.09 0.38
Onsite
Total 11.83 43% 0.56 0.70 18.67 81.49
year.
Snow Removal
Mechanical snow and ice removal should be
used. Conventional plowing operations
should not cause damage to the pavement.
Sand should not be used
Routine – throughout winter season
Full and Partial
Replacement of
Pavement of Infill
Material
Follow industry guidelines for installation and
replacement after underground repairs.
Restore sureface infiltration by removing 1/2"
to 1" of soiled aggregate infill material with a
vacuum sweeper. After cleaning, openings in
the pavement need to be refilled with clean
aggregate infill materials via a push broom.
After poor installation of paver blocks, or
when surface is completely clogged and
rendering a minimal surface infiltration rate.
Date: 3/16/2015 Trapezoidal-Weir (outlet structure sizing).xls
(Figure MD-21)
Rectangular
Pipe
(Figure MD-22) Spec
Min. Width
of
Riprap
(ft)
2*d50,
Depth
of
Riprap
(ft)
for L/2
Froude
Parameter
Q/D2.5
Max 6.0
or
Q/WH1.5
Max 8.0
Calculations by: KRB
Date: 3/16/2015 C:\United Civil\Dropbox\Projects\U14012 - Liberty Ridge\Drainage\Hydraulics\Riprap\Riprap Calcs Spreadsheet.xls
Final
tc
(6)
tc Check for Urbanized
Basin
Initial Overland Flow Time (ti) Travel/Channelized Time of Flow (tt)
Design
Pt.
Initial
Ground
Type
C5
(1) Cv
ti+tt
Calculations by: KRB
Date: 3/16/2015 C:\United Civil\Dropbox\Projects\U14012 - Liberty Ridge\Drainage\Hydrology\Runoff (Fort Collins).xlsx