Loading...
HomeMy WebLinkAboutCULTIVATION FACILITY (5608 S. COLLEGE AVE.) - PDP150004 - SUBMITTAL DOCUMENTS - ROUND 1 - SITE, LANDSCAPE & ELEVATIONS PLANSS. COLLEGE AVE. SE Frontage Road Bueno Drive DRAWING NUMBER: 401 West Mountain Avenue Suite 200 Fort Collins, CO 80521 fax 970/224.1662 phone 970/224.1191 www.vfrdesigninc.com Ŷ land planning Ŷ landscape architecture Ŷ Ŷ urban design Ŷ entitlement Ŷ ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: OWNER APPLICANT ARCHITECT ENGINEER MEP ENGINEER PREPARED BY: No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE FORT COLLINS, COLORADO CULTIVATION FACILITY PROJECT DEVELOPMENT PLAN RIPLEY DESIGN INC. Linda Ripley 401 W. Mountain Avenue, Suite 100 Fort Collins, CO 80521 p. 970.224.1191 f. 970.224.1662 NORTHERN ENGINEERING Cody Snowdon 200 South College Avenue Suite 100 Fort Collins, CO 80524 p. 970.221.4158 L1 COVER SHEET 0 250 500 1000 SCALE: 1"=500'-0" CULTIVATION FACILITY PROJECT LOCATION THIS IS A LAND USE PLANNING DOCUMENT, NOT A CONSTRUCTION DOCUMENT. REFER TO CIVIL ENGINEERING PLANS. 1. REFER TO CIVIL ENGINEERING PLANS FOR GRADING, SIDEWALKS AND UTILITIES. 2. ALL DIMENSIONS TO BE VERIFIED ON SITE. 3. ALL FOOTINGS / FOUNDATIONS TO BE REVIEWED BY A STRUCTURAL ENGINEER PRIOR TO CONSTRUCTION. 4. ALL LIGHTING TO BE COORDINATED WITH LIGHTING CONSULTANT. 5. PROVIDE COMPLETE CONSTRUCTION DETAILS FOR LANDSCAPE ARCHITECT TO REVIEW PRIOR TO BEGINNING CONSTRUCTION. GENERAL NOTES VICINITY MAP LEGAL DESCRIPTION LOT 1, SOUTH 13 SUB, FTC T T T T T T T T T T T T T T T T T T T T T T T E E G G G G G G G G G G G X X X X X X X X X X X X X X X X X X X W W W W W W W E E E E E E E LOW DENSITY RESIDENTIAL DISTRICT SERVICE COMMERCIAL DISTRICT SERVICE COMMERCIAL DISTRICT USE - SERVICE COMMERCIAL DISTRICT BUILDING SF - 3,600 PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE 11'-4" 8'-0" 19'-0" TYP 48'-0" 19'-0" 11'-7" T T T T T T T T T T T T T T T T T T T T T T T E E G G G G G G G G G G G X X X X X X X X X X X X X X X X X X X W W W W W W W E E E E E E E 4 AH 3 SW 3 LL 2 LL FORT COLLINS, COLORADO Linda Pixley 5608 South College, Fort Collins, CO 80525 p. 970.xxx.xxxx 0 05 10 20 SCALE: 1"=10'-0" DRAWING NUMBER: 401 West Mountain Avenue Suite 200 Fort Collins, CO 80521 fax 970/224.1662 phone 970/224.1191 www.vfrdesigninc.com Ŷ land planning Ŷ landscape architecture Ŷ Ŷ urban design Ŷ entitlement Ŷ ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: OWNER APPLICANT ARCHITECT ENGINEER MEP ENGINEER PREPARED BY: No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE THIS IS A LAND USE PLANNING DOCUMENT, NOT A CONSTRUCTION DOCUMENT. REFER TO CIVIL ENGINEERING PLANS. L4 LANDSCAPE NOTES & DETAILS DRS LR R14-080 PRUNING NOTES: DO NOT HEAVILY PRUNE SHRUB AT PLANTING. PRUNE ONLY DEAD OR BROKEN BRANCHES. IF FORM IS COMPROMISED BY PRUNING, REPLACE SHRUB PLACEMENT NOTES: SET SHRUB PLUMB. SPACE PLANTS, AND PLACE FOR BEST EFFECT SET TOP OF ROOTBALL 1-2" HIGHER THAN ADJACENT GRADE SCARIFY SIDES AND USE 1:1 SLOPE 4" DEEP MULCH RING 3' IN DIA. PLACE ON GEOTEXTILE WEED BARRIER REMOVE CONTAINER (INCLUDING FIBER CONTAINERS), BASKETS, WIRE, ETC. FROM THE ROOTBALL. BREAK UP ENCIRCLING ROOTS WITH SHARP KNIFE OR SPADE. SPLIT BOTTOM OF ROOT BALL. PLACE ON UNDISTURBED SOIL TO PREVENT SETTLEMENT BACKFILL WITH BLEND OF EXISTING SOIL AND A MAX. 20% (BY VOL.) ORGANIC MATERIAL. WATER FORT COLLINS, COLORADO DRAWING NUMBER: 401 West Mountain Avenue Suite 200 Fort Collins, CO 80521 fax 970/224.1662 phone 970/224.1191 www.vfrdesigninc.com Ŷ land planning Ŷ landscape architecture Ŷ Ŷ urban design Ŷ entitlement Ŷ ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: OWNER APPLICANT ARCHITECT ENGINEER MEP ENGINEER PREPARED BY: No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE THIS IS A LAND USE PLANNING DOCUMENT, NOT A CONSTRUCTION DOCUMENT. REFER TO CIVIL ENGINEERING PLANS. L5 BUILDING ELEVATIONS DRS LR R14-080 RIPLEY DESIGN INC. Linda Ripley 401 W. Mountain Avenue, Suite 100 Fort Collins, CO 80521 p. 970.224.1191 f. 970.224.1662 NORTHERN ENGINEERING Cody Snowdon 200 South College Avenue Suite 100 Fort Collins, CO 80524 p. 970.221.4158 01 BUILDING ELEVATION - NORTH SCALE: NTS 02 BUILDING ELEVATION - EAST SCALE: NTS 03 BUILDING ELEVATION - SOUTH SCALE: NTS 04 BUILDING ELEVATION - WEST SCALE: NTS CULTIVATION FACILITY PROJECT DEVELOPMENT PLAN THOROUGHLY TO SETTLE AND REMOVE AIR POCKETS 2 X BALL DIA. 4" HIGH WATER SAUCER SHRUB PLANTING DETAIL 1 SCALE: NTS L-XS-MUN-FOCO-04 RIPLEY DESIGN INC. Linda Ripley 401 W. Mountain Avenue, Suite 100 Fort Collins, CO 80521 p. 970.224.1191 f. 970.224.1662 NORTHERN ENGINEERING Cody Snowdon 200 South College Avenue Suite 100 Fort Collins, CO 80524 p. 970.221.4158 1. EXISTING TREES MARKED FOR PROTECTION AND PRESERVATION SHALL NOT BE REMOVED. 2. HEAVY EQUIPMENT SHOULD NOT BE ALLOWED TO COMPACT OVER THE ROOT ZONE OF EXISTING TREES. 3. AVOID CUTTING SURFACE ROOTS WHENEVER POSSIBLE. SIDEWALKS AND PAVING LEVELS SHOULD BE CONTOURED SUFFICIENTLY TO AVOID DAMAGE. 4. ROOT CUTS FROM EXCAVATION SHOULD BE DONE RAPIDLY. SMOOTH FLUSH CUTS SHOULD BE MADE. BACKFILL BEFORE THE ROOTS HAVE A CHANCE TO DRY OUT AND WATER THE TREE IMMEDIATELY. 5. PRIOR TO CONSTRUCTION, ALL PROTECTED TREES SHALL HAVE ORANGE PROTECTION BARRIER FENCING ERECTED, WHICH AS A MINIMUM ARE SUPPORTED BY 1" X 1" OR SIMILAR STURDY STOCK, FOR SHIELDING OF PROTECTED TREES, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE HALF (1 2) OF THE DRIP LINE, WHICH EVER IS GREATER. WITHIN THIS PROTECTION ZONE THERE SHALL BE NO MOVEMENT OF EQUIPMENT OR STORAGE OF EQUIPMENT, MATERIALS, DEBRIS, FILL OR CUT UNLESS APPROVED BY THE CITY FORESTER. 6. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 7. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE OR DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE, WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 8. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 9. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BY "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN NOTE (5) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POSTS STAKES A MAXIMUM OF FIFTY FEET APART AND TYING A RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 10. ALL EXISTING TREES SHALL BE PRUNED TO THE CITY FORESTER'S "MEDIUM PRUNE STANDARDS". TREE PROTECTION NOTES TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 NORTH CULTIVATION FACILITY PROJECT DEVELOPMENT PLAN 5 VN 1 PP7 3 SW 3 LL 02 03 01 BROADLEAVED EVERGREEN CODE QTY BOTANICAL NAME / COMMON NAME SIZE AH 4 ARCTOSTAPHYLOS X COLORADOENSIS `PANCHITO` / PANCHITO MANZANITA 5 GAL ORNAMENTAL GRASS CODE QTY BOTANICAL NAME / COMMON NAME SIZE SW 6 SPOROBOLUS WRIGHTII / GIANT SACATON 5 GAL SMALL DECIDUOUS SHRUBS CODE QTY BOTANICAL NAME / COMMON NAME SIZE LL 8 LIGUSTRUM VULGARE `LODENSE` / LODENSE PRIVET 5 GAL PP7 1 PRUNUS BESSEYI `PAWNEE BUTTES` / DWARF WESTERN SAND CHERRY 5 GAL VN 5 VIBURNUM OPULUS `NANUM` / DWARF EUROPEAN CRANBERRYBUSH 5 GAL PLANT SCHEDULE SYMBOL DESCRIPTION QTY MIXED COBBE 2"-4" SIZE AVERAGE WITH WEED BARRIER. 6.31 CY TYPE COUNT REQUIRED MITIGATION MATERIAL LIST TREES TREES BEING PRESERVED 3 0 TREES TO BE REMOVED 0 0 TOTAL 3 0 TREE MITIGATION LEGEND EXISTING TO SAVE IN PLACE XXX # TYPE SIZE CONDITION REQUIRED MITIGATION TREES IF REMOVED 1 HONEY LOCUST 2" FAIR-- NA 2 HONEY LOCUST 12" FAIR NA 3 HONEY LOCUST 12" FAIR NA TREE MITIGATION SUMMARY FORT COLLINS, COLORADO 0 05 10 20 SCALE: 1"=10'-0" DRAWING NUMBER: 401 West Mountain Avenue Suite 200 Fort Collins, CO 80521 fax 970/224.1662 phone 970/224.1191 www.vfrdesigninc.com Ŷ land planning Ŷ landscape architecture Ŷ Ŷ urban design Ŷ entitlement Ŷ ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: OWNER APPLICANT ARCHITECT ENGINEER MEP ENGINEER PREPARED BY: No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE THIS IS A LAND USE PLANNING DOCUMENT, NOT A CONSTRUCTION DOCUMENT. REFER TO CIVIL ENGINEERING PLANS. THIS IS A LAND USE PLANNING DOCUMENT, NOT A CONSTRUCTION DOCUMENT. REFER TO CIVIL ENGINEERING PLANS. L3 LANDSCAPE AND MITIGATION PLAN DRS LR R14-080 RIPLEY DESIGN INC. Linda Ripley 401 W. Mountain Avenue, Suite 100 Fort Collins, CO 80521 p. 970.224.1191 f. 970.224.1662 NORTHERN ENGINEERING Cody Snowdon 200 South College Avenue Suite 100 Fort Collins, CO 80524 p. 970.221.4158 1. ALL PLANT MATERIAL SHALL MEET SPECIFICATIONS OF THE AMERICAN ASSOCIATION OF NURSERYMEN (AAN) FOR NUMBER ONE GRADE. ALL TREES SHALL BE BALLED AND BURLAPPED OR EQUIVALENT. 2. ALL TREES TO BE BALLED & BURLAPPED, CONTAINERIZED, OR ROOT CONTROL BAGS. 3. ALL TURF AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC POP-UP IRRIGATION SYSTEM. ALL SHRUBS AND TREES, INCLUDING WITHIN NATIVE SEED AREAS, ARE TO BE IRRIGATED WITH AN AUTOMATIC DRIP IRRIGATION SYSTEM. ALL PERENNIALS AND ORNAMENTAL GRASSES SHALL BE DRIP OR SPRAY IRRIGATED. ALL TREES (EVERGREEN OF DECIDUOUS) SHALL BE INDIVIDUALLY DRIP IRRIGATED ON AN IRRIGATIION ZONE SEPARATE FROM THE TURF AREAS. 4. ALL IRRIGATION SHALL BE INSTALLED IN ACCORDANCE WITH THE APPROVED IRRIGATIONS PLANS. THE IRRIGATION SYSTEM SHALL BE DESIGNED TO MEET THE WATER REQUIREMENTS OF THE INDIVIDUAL PLANT MATERIAL. 5. THE IRRIGATION SYSTEM SHALL BE REVIEWED AND APPROVED BY THE TOWN OF FREDERICK PRIOR TO FINAL LANDSCAPE APPROVAL. 6. ALL SHRUB BEDS TO BE MULCHED WITH SHREDDED WOOD MULCH IN PLANT ZONE AREAS AND GRAVEL MULCH IN REMAINING BED PERIMETER AREAS. WOOD AND GRAVEL MULCHES SHALL BE AT A 3" AVERAGE DEPTH OVER LANDSCAPE FABRIC. WOOD MULCH SHALL BE DISTRIBUTED AT A MINIMUM ONE (1) CUBIC YARD PER EIGHTY (80) SQUARE FEET. ALL PERENNIALS AND ANNUALS TO BE MULCHED WITH SHREDDED WOOD MULCH AT 3" AVERAGE DEPTH OVER LANDSCAPE FABRIC. INDIVIDUAL TREES IN SOD AND NATIVE SEED AREAS SHALL RECEIVE 3" DEPTH SHREDDED WOOD MULCH IN THE TREE RING AREAS WITHOUT LANDSCAPE FABRIC. 7. ALL BED AREAS TO BE SEPARATED FROM SEED OR SOD AREAS WITH 4" EDGER. EDGER SHALL BE SET LEVEL WITH THE TOP OF SOD. 8. OWNER SHALL ENSURE THAT THE LANDSCAPE PLAN IS COORDINATED WITH THE PLANS DONE BY OTHER CONSULTANTS SO THAT THE PROPOSED GRADING, STORM DRAINAGE, OR OTHER CONSTRUCTION DOES NOT CONFLICT NOR PRECLUDE INSTALLATION AND MAINTENANCE OF LANDSCAPE ELEMENTS ON THIS PLAN. 9. MINOR CHANGES IN SPECIES AND PLANT LOCATIONS MAY BE MADE DURING CONSTRUCTION AS REQUIRED BY SITE CONDITIONS OR AVAILABILITY. ANY CHANGES SHALL REFLECT THE ORIGINAL QUALITY AND DESIGN CONCEPT OF THE APPROVED LANDSCAPE PLANS. ANY CHANGES SHALL BE PROVIDED TO PROJECT LANDSCAPE ARCHITECT PRIOR TO FINAL APPROVAL. 10. TOPSOIL. TO THE MAXIMUM EXTENT FEASIBLE, TOPSOIL THAT IS REMOVED DURING CONSTRUCTION ACTIVITY SHALL BE CONSERVED FOR LATER USE. 11. SOIL AMENDMENTS. PRIOR TO INSTALLATION OF PLANT MATERIALS, AREAS THAT HAVE BEEN COMPACTED OR DISTURBED BY CONSTRUCTION ACTIVITY SHALL BE THOROUGHLY LOOSENED. ORGANIC AMENDMENTS SUCH AS COMPOST, PEAT, OR AGED MANURE SHALL BE THOROUGHLY INCORPORATED - SEE SPECS. 12. GUARANTEE OF INSTALLATION. REQUIRED LANDSCAPE IMPROVEMENTS SHALL BE INSTALLED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY OR FINAL INSPECTION FOR ALL STRUCTURES. IF WEATHER CONDITIONS PREVENT INSTALLATION, THE DEVELOPER SHALL POST A FINANCIAL GUARANTEE FOR THE INSTALLATION OF THE IMPROVEMENTS, BASED ON AN ESTIMATE OF THE TOTAL COST FOR INSTALLATION PLUS TWENTY-FIVE PERCENT (125%). THE TOTAL COST OF INSTALLATION SHALL INCLUDE ALL REQUIRED LABOR, MATERIALS, AND ALL NECESSARY ACTIVITIES REQUIRED FOR INSTALLATION OF THE APPROVED LANDSCAPING. THIS GUARANTEE SHALL BE RELEASED UPON COMPLETION OF TWO GROWING SEASONS AFTER INITIAL APPROVAL OF THE INSTALLATION BY THE TOWN. 13. ALL LANDSCAPING SHALL BE MAINTAINED IN GOOD HEALTH AND REPLACED BY THE LANDOWNER OR OCCUPANT AS NECESSARY. ALL PROPERTY OWNERS OR OCCUPANTS SHALL BE RESPONSIBLE FOR MAINTENANCE OF LANDSCAPING WITHIN THE PORTION OF THE PUBLIC RIGHT-OF-WAY BETWEEN THE BACK OF THE CURB OR STREET PAVEMENT AND THE ADJACENT PROPERTY. 14. LANDSCAPE AND UTILITY PLANS SHALL BE COORDINATED. THE FOLLOWING SETS FORTH MINIMUM DIMENSION REQUIREMENTS FOR THE MOST COMMON TREE AND UTILITY SEPARATIONS. EXCEPTIONS TO THESE REQUIREMENTS MAY OCCUR WHERE UTILITIES ARE NOT LOCATED IN THEIR STANDARD DESIGNATED LOCATIONS, OR AS APPROVED BY THE TOWN. TREE AND UTILITY SEPARATIONS SHALL NOT BE USED AS A MEANS OF AVOIDING THE PLANTING OF REQUIRED STREET TREES. A. FORTY (40) FEET BETWEEN SHADE TREES AND STREETLIGHTS AND FIFTEEN (15) FEET BETWEEN ORNAMENTAL TREES AND STREETLIGHTS. B. FIFTEEN (15) FEET BETWEEN TREES AND WATER, SEWER MAINS, AND GAS COLLECTION LINES. C. SIX (6) FEET BETWEEN TREES AND WATER, SEWER, AND GAS SERVICE LINES. D. STREET TREES ON LOCAL STREETS PLANTED WITHIN FIVE (5) FEET OF UNDERGROUND UTILITY EASEMENTS MAY ROOT NEAR UNDERGROUND UTILITIES. ADDITIONAL CONDUIT MAY BE REQUIRED TO MINIMIZE DAMAGE TO TREES WHEN SERVICING UNDERGROUND UTILITY LINES. LANDSCAPE NOTES NORTH CULTIVATION FACILITY PROJECT DEVELOPMENT PLAN 8'-0" TYP 1 2 3 4 50'-0" 72'-0" HANDICAP STRIPING AND SIGNAGE PER LCUSS DETAIL 1407 WHEEL STOPS (TYP.) PROPOSED HANICAP RAMP PROPOSED LANDSCAPE ISLANDS PROPOSED BIKE RACK W/STRIPING PERVIOUS AREA ADDED. SEE CIVIL PLANS. PROPOSED GATE GRAVEL TO REMAIN 20' POWER & PHONE UTILITY EASEMENT 20' POWER & PHONE UTILITY EASEMENT 25' WATER & SEWER UTILITY EASEMENT GRAVEL TO REMAIN PROPOSED GATE 6' UTILITY EASEMENT PROPOSED BARRIER CURB 2.95' EXISTING CONCRETE TO REMAIN 8'-9" 9'-1" COMPOST & TRASH ENCLOSURE TO BE LOCATED INSIDE BUILDING CALCULATIONS LUC 3.2.1(E)(5) PARKING LOT INTERIOR LANDSCAPING REQUIRED - 123.12SF PROVIDED - 179SF PLANTED AREA FORT COLLINS, COLORADO DRS LR 0 05 10 20 SCALE: 1"=10'-0" DRAWING NUMBER: 401 West Mountain Avenue Suite 200 Fort Collins, CO 80521 fax 970/224.1662 phone 970/224.1191 www.vfrdesigninc.com Ŷ land planning Ŷ landscape architecture Ŷ Ŷ urban design Ŷ entitlement Ŷ ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: OWNER APPLICANT ARCHITECT ENGINEER MEP ENGINEER PREPARED BY: No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE THIS IS A LAND USE PLANNING DOCUMENT, NOT A CONSTRUCTION DOCUMENT. REFER TO CIVIL ENGINEERING PLANS. R14-080 PROJECT PARKING *REQUIRED PROVIDED LONG-TERM PARKING STALLS 4 4 HANDICAP 1 1 TOTAL 5 5 BICYCLE PARKING *REQUIRED PROVIDED BICYCLE SPACES 4 4 * PARKING CALCULATIONS ASSUME INDUSTRIAL 0.75 SPACES / EMPLOYEE ASSUMING 4 TO 6 EMPLOYEES) EXISTING ZONING SERVICE COMMERCIAL DISTRICT (CS) NET NET AREA 15,989 SF (.36 AC) TOTAL DWELLING UNITS 1 DENSITY LAND USE CHART L2 SITE PLAN RIPLEY DESIGN INC. Linda Ripley 401 W. Mountain Avenue, Suite 100 Fort Collins, CO 80521 p. 970.224.1191 f. 970.224.1662 NORTHERN ENGINEERING Cody Snowdon 200 South College Avenue Suite 100 Fort Collins, CO 80524 p. 970.221.4158 NORTH NOTE x ALL EXTERIOR LIGHTING SHALL BE FULLY SHIELDED AND DOWN DIRECTIONAL. CULTIVATION FACILITY PROJECT DEVELOPMENT PLAN DRS LR R14-080 Sheet List Table Sheet Number Sheet Title L1 Cover Sheet L2 Site Plan L3 Landscape and Mitigation Plan L4 Landscape Notes & Details L5 Building Elevations NORTH