December 05, 2014
Eric Morff
COLE & ASSOCIATES, INC.
401 S 18TH STREET SUITE 200
St. Louis, MO 63103
Comment Summary:
Department: Planning Services
Contact: Noah Beals, 970-416-2313, nbeals@fcgov.com
Topic: General
12/02/2014: The lighting plan will need to include catalog cut-sheets of the fixtures.
Comment Number: 1 Comment Originated: 12/02/2014
12/02/2014: On the cover sheet of the Planning set please change the Director of Planning signature
block to match the Director of Community Development and Neighborhood Services signature block
found on the Plat.
Comment Number: 2 Comment Originated: 12/02/2014
12/02/2014: On the Cover sheet the index will need to include all the sheets that are not in the utility
plans or plat, i.e. landscape, lighting plan.
Comment Number: 3 Comment Originated: 12/02/2014
12/02/2014: Why is the public sidewalk set back 2 feet from the property line?
Comment Number: 4 Comment Originated: 12/02/2014
12/02/2014: Land Use Code (LUC) Section 3.2.2(C)(5)(b) Requires walkways on both sides of the
drive aisle. The access on from Ziegler Road shows only an attached sidewalk along the south side
of the drive aisle. This sidewalk goes straight into the ramp of the sidewalk. Detach the sidewalk from
the drive aisle and provide it on both sides of the drive aisle. The sidewalk on the north side should
curve to meet the north adjoining property.
Comment Number: 5 Comment Originated: 12/02/2014
Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of
the above referenced project. If you have questions about any comments, you may contact the individual
commenter or direct your questions through the Project Planner, Noah Beals, at 970-416-2313 or
nbeals@fcgov.com.
RE: Mainstreet Health & Wellness Suites, PDP140018, Round Number 1
Page 1 of 15
12/02/2014: A sidewalk connection is needed along the west side of the drive aisle that connects to
precision drive. This should be detached from the drive aisle and connect into the internal sidewalk
system.
Comment Number: 6 Comment Originated: 12/02/2014
12/02/2014: The off-street parking spaces do not add up to 96 total spaces as indicated on the cover
sheet. The on street parking spaces are not to be included.
Comment Number: 7 Comment Originated: 12/02/2014
12/02/2014: The sidwalkway system in the landscape islands do align. These need to be aligned
The sidewalk system on the landscape plan does not match that of the site plan.
Comment Number: 8 Comment Originated: 12/02/2014
12/02/2014: Parking stalls cannot exceed 15 in a row. An landscape island is required every 15
spaces.
Comment Number: 9 Comment Originated: 12/02/2014
12/02/2014: The Planting schedule will need to include quantities. The street trees need more
diversity. Please do not use on specie along the entire right-of-way.
Comment Number: 10 Comment Originated: 12/02/2014
12/02/2014: The Alternative compliance request to the build-to line along should include trees on both
sides of the public side walk.
Also are the outdoor patio's for employee use? If not is there an outdoor area designated for
employees?
Comment Number: 11 Comment Originated: 12/02/2014
12/02/2014: The site plan labels the the water quality pond as a retention pond, is this correct or is it a
detention pond? Why is the pond sparse in landscaping?
Comment Number: 12 Comment Originated: 12/02/2014
12/02/2014: The elevations need to show the height of the building to the tallest point.
It appears the building may be over 40 ft in height? If so further analysis will need t to be provided.
Comment Number: 13 Comment Originated: 12/02/2014
12/02/2014: The elevation 3-d perspective does not match the other elevation drawings.
Can you provide 1 color copy of the elevations? It is difficult to read the articulation and in the building
and the materials.
Comment Number: 14 Comment Originated: 12/02/2014
Department: Engineering Development Review
Contact: Marc Virata, 970-221-6567, mvirata@fcgov.com
Topic: Construction Drawings
12/03/2014: 1" = 60' isn't allowed for plan view (and profile view) per LCUASS 3.2.7. The 60 scale on
sheet 18 would need to be modified. In general, even though 50 scale is allowed in this standard, I'm
concerned that the information being provided in 50 scale will be difficult to read when the information
required with a final plan submittal is then added. The road plan and profile information should ideally
then be provided at a 30 or 40 scale.
Comment Number: 11 Comment Originated: 12/03/2014
Page 2 of 15
12/03/2014: The grading plan is not showing the property boundary.
Comment Number: 12 Comment Originated: 12/03/2014
12/03/2014: For final on the Precision Drive plan and profile, please ensure that flowline sump
conditions of .5% do not utilize a vertical curves.
Comment Number: 13 Comment Originated: 12/03/2014
Topic: General
12/03/2014: The plans indicate references to various work being done either by "owner" or "by
others". These references should be removed as the work being done is considered required by the
developer in conjunction with the project and the City won't make a distinction between different
parties. My presumption is that Precision Drive will be constructed from Technology Parkway to Ziegler
Road with the development plan.
Comment Number: 2 Comment Originated: 12/03/2014
12/03/2014: In general, the plans need to show what infrastructure is to be fully built with the project in
bold, with the existing condition faded. The site and civil plans for instance should show Precision
Drive not in an existing lineweight, but proposed. On the site and landscape plans, Precision Drive
should be shown connecting to Technology Parkway.
Comment Number: 3 Comment Originated: 12/03/2014
12/03/2014: The plans need to depict how the Intel property to the north will change with the closure of
the driveway abutting the property. Show the addition of curb and gutter and removal of the driveway
approach, indicate what landscaping is to be added, etc.
Comment Number: 4 Comment Originated: 12/03/2014
12/03/2014: There appears to be some grading for Precision Drive that falls outside of the Precision
Drive right-of-way on the south side. Additionally there appears to be some utility and potentially
drainage work that falls outside of right-of-way and outside of the future utility easement. There may be
some benefits in having the plat also included the two unplatted properties east and south of the
proposed development, as this would allow easements that are needed offsite of the actual
development to be provided via the plat. In general, an understanding of what work is occurring
outside of the property, right-of-way, and/or an easement needs to be understood at this time. There's
two proposed storm sewer for outfall on the south side of Precision Drive that would seem to need
easements established onto that property.
Comment Number: 5 Comment Originated: 12/03/2014
Topic: Landscape Plans
12/03/2014: The Landscape plan doesn't show the curb returns for Precision Drive intersecting Ziegler
Road. I suspect that the indication of the curb returns might conflict with the street tree furthest south
along Ziegler Road and may need to be adjusted accordingly.
Comment Number: 14 Comment Originated: 12/03/2014
Topic: Plat
12/03/2014: The Ziegler Road right-of-way needs to show what the existing right-of-way is for the full
width of the road for verification that the amount of right-of-way abutting the property is in conformance
with City requirements.
Comment Number: 6 Comment Originated: 12/03/2014
12/03/2014: Right-of-way for Precision Drive should not have the irrigation easement shown crossing
the right-of-way, the pipe crossing will then be permitted through an encroachment permit.
Comment Number: 7 Comment Originated: 12/03/2014
Page 3 of 15
12/03/2014: The plat needs to show an access easement from the Intel access being tied into, out to
the driveway that connects out to Ziegler to ensure that shared access can be maintained onto this
property.
Comment Number: 8 Comment Originated: 12/03/2014
12/03/2014: Who is the party that would need to sign the plat and plans for the private irrigation
easement? In general there should be some description on the intent of the private irrigation easement
that differentiates it from the "Easements" indicated in the "Certificate of Dedication". (The Aspen civil
set has a signature block for Poudre School District, might this be the party that would need to sign?)
The signature for the party should be on the plat and the civil cover sheet (Cole).
Comment Number: 9 Comment Originated: 12/03/2014
12/03/2014: Irrigation pipe cover over Precision Drive is substandard with 2.5 feet of cover. Additional
cover is needed.
Comment Number: 10 Comment Originated: 12/03/2014
Contact: Sheri Langenberger, 970-221-6573, slangenberger@fcgov.com
Topic: General
11/07/2014: The Transporation Development Review Fee (TDRF) amount that was paid was not
correctly calculated and the actual amount owed for the PDP application was less than what you paid. I
have requested a refund of $5,977.75 be processed. The total amount that was due based on current
building square footage and area being platted is: $21,763.50
Comment Number: 1 Comment Originated: 11/07/2014
Department: Forestry
Contact: Tim Buchanan, 970-221-6361, tbuchanan@fcgov.com
Topic: Landscape Plans
12/03/2014:
The following comments pertain only to trees and tree related issues on the proposal.
Comment Number: 1 Comment Originated: 12/03/2014
12/03/2014:
The street tree design for species variation by grouping of different species within rows should follow
the standards in the Larimer County Urban Area Street standards appendix C, Streetscape Standards
Fort Collins section 4.1.1 titled Species Groupings within Tree Rows. Street tree selection should be
from the City of Fort Collins Street Tree List.
Comment Number: 2 Comment Originated: 12/03/2014
12/03/2014:
List quantities of trees used in the Plant schedule and the percentage of each tree species use.
Minimum tree species diversity should be followed as described in LUC 3.2.1 D 3.
Comment Number: 3 Comment Originated: 12/03/2014
12/03/2014:
The first street tree on Ziegler just north of Precisions is close to the corner an could cause sight
visibility problems. Evaluate for deletion.
Comment Number: 4 Comment Originated: 12/03/2014
Page 4 of 15
12/03/2014:
Show locations of street lights and space canopy and ornamental trees away from any street lights to
meet the LUC standard 3.2.1 K 1. If there are street lights by the main facility design ornamental trees
within 15 feet of the light and use canopy shade trees in all other parkway locations. This would be
similar to the street tree design shown on Precision Drive on landscape sheet 2 of 2.
Comment Number: 5 Comment Originated: 12/03/2014
12/03/2014:
Please add these street tree notes under a separate heading labeled Street Tree Notes.
1. A permit must be obtained from the City Forester before any trees or shrubs as noted on this plan
are planted, pruned or removed on the public right-of-way. This includes zones between the sidewalk
and curb, medians and other City property. This permit shall approve the location and species to be
planted. Failure to obtain this permit may result in replacing or relocating trees and a hold on certificate
of occupancy.
2. Contact the City Forester to inspect all street tree plantings at the completion of each phase of the
development. All trees need to have been installed as shown on the landscape plan. Approval of
street tree planting is required before final approval of each phase.
3. Street tree shall be supplied and planted by the developer using a qualified landscape contractor.
4. The developer shall replace all dead and dying street trees after planting until final maintenance
inspection and acceptance by the City of Fort Collins Forestry Division. All street trees in the project
must be established of an approved species and of acceptable condition prior to acceptance.
5. Street tree locations and numbers may be adjusted to accommodate driveway locations, utility
standards, separation between trees, street signs and street lights. Street trees shall be centered in
the middle of the parkway. Quantities shown on plan must be installed unless a reduction occurs to
meet separation standards.
Comment Number: 6 Comment Originated: 12/03/2014
12/03/2014:
Please place the following note on the landscape plan in larger bold print with a bold border around
the note.
A free permit must be obtained from the City Forester before any street trees are planted in parkways
between the sidewalk and Curb. Street tree locations and numbers may change to meet actual
utility/tree separation standards. Landscape contractor must obtain approval of street tree location after
utility locates. Street trees must be inspected and approved before planting. Failure to obtain this
permit is a violation of the Code of the City of Fort Collins.
Comment Number: 7 Comment Originated: 12/03/2014
Page 5 of 15
12/03/2014:
Tree species selection:
1. Please change Celebration Maple to another canopy shade tree. Celebration Maple and other
hybrids between Silver Maple and Red Maple are not adapted to the soils in the Fort Collins area and
do not survive and thrive long term.
2. The two ornamental trees shown on the plan are not typically used wide scale as ornamental trees
on local projects. These include Saskatoon Serviceberry and Rocky Mountain Birch. The native
serviceberry is actually a large shrub. The following are some good ornamental trees often used by
designers that should be considered for use on the project the provide variation in tree form and
ornamental interest.
Radiant Crabapple
Chanticleer Pear
Hotwings Tatarian Maple
Thunderchild Crabapple
Spring Snow Crab apple
Ivory Silk Tree Lilac
3. Austrian Pine would be a better adapted conifer tree to the area than Limber Pine.
4. Please label the Bur Oak as Bullet Gall Resistant by putting that statement by the common name.
Comment Number: 8 Comment Originated: 12/03/2014
12/03/2014:
Review the full tree stocking standard in LUC 3.2.1 1 c and evaluate the need to add additional trees
on high visibility and use sides of the building.
Comment Number: 9 Comment Originated: 12/03/2014
12/03/2014:
Review the Parking Lot Interior Landscaping standards found in LUC 3.2.1 5. Evaluate the need to add
additional trees to the long parking lot island north of the building.
Comment Number: 10 Comment Originated: 12/03/2014
12/03/2014:
Additional landscape notes:
The following plant notes or equivalent should be added to the General Landscape and Planting Notes
found on sheet L1 of 4.
Please add these notes that are found on the landscape plan for Precision Drive that are on sheet 1 of
2.
2,6,7,8,11,12,13,17,20
Comment Number: 11 Comment Originated: 12/03/2014
Department: Internal Services
Contact: Russell Hovland, 970-416-2341, rhovland@fcgov.com
Topic: Building Insp Plan Review
Page 6 of 15
12/03/2014:
Building Permit Pre-Submittal Meeting
Pre-Submittal meetings are offered to assist the designer/builder by assuring, early on in the design,
that the new commercial or multi-family projects are on track to complying with all of the adopted City
codes and Standards listed below. The proposed project should be in the early to mid-design stage
for this meeting to be effective and is typically scheduled after the Current Planning conceptual review
meeting. Applicants of new commercial or multi-family projects are advised to call 416-2341 to
schedule a pre-submittal meeting. Applicants should be prepared to present site plans, floor plans,
and elevations and be able to discuss code issues of occupancy, square footage and type of
construction being proposed.
Construction shall comply with the following adopted codes as amended:
2012 International Building Code (IBC)
2012 International Residential Code (IRC)
2012 International Energy Conservation Code (IECC)
2012 International Mechanical Code (IMC)
2012 International Fuel Gas Code (IFGC)
2012 International Plumbing Code (IPC) as amended by the State of Colorado
2014 National Electrical Code (NEC) as amended by the State of Colorado
Accessibility: State Law CRS 9-5 & ICC/ANSI A117.1-2009.
Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF.
Frost Depth: 30 inches.
Wind Load: 100- MPH 3 Second Gust Exposure B.
Seismic Design: Category B.
Climate Zone: Zone 5
Energy Code Use
1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC.
2. Multi-family and Condominiums 3 stories max: 2012 IECC residential chapter.
3. Commercial and Multi-family 4 stories and taller: 2012 IECC commercial chapter.
Comment Number: 2 Comment Originated: 12/03/2014
Contact: Todd Reidenbach, ,
Topic: General
11/26/2014: Addresses will be assigned by the GIS Department after the plans have met final
approval through Development Review and are recorded with the City
Todd Reidenbach, GISP
GIS Mapping Specialist
treidenbach@fcgov.com
970.416.2483 Work
970.221.6329 Fax
Comment Number: 1 Comment Originated: 11/26/2014
Department: Light And Power
Contact: Justin Fields, 970-224-6150, jfields@fcgov.com
Topic: General
Page 7 of 15
11/28/2014: Electric development and system modification charges will apply. An online estimator for
these charges is available at
http://www.fcgov.com/utilities/business/builders-and-developers/plant-investment-development-fees/el
ectric-development-fee-estimator?id=3.
Comment Number: 1 Comment Originated: 11/28/2014
11/28/2014: The transformer and meter locations need to be coordinated with Light and Power
Engineering, 970-221-6700.
Comment Number: 2 Comment Originated: 11/28/2014
11/28/2014: A C-1 form and one-line diagram need to submitted to Light and Power Engineering. The
C-1 form is available at http://www.fcgov.com/utilities/img/site_specific/uploads/c-1_form.pdf.
Comment Number: 3 Comment Originated: 11/28/2014
11/28/2014: Contact Light and Power Engineering for a layout of the streetlights along Ziegler and
adjust the street trees accordingly. Shade trees need to maintain 40 feet of clearance with streetlights
and ornamental trees need to maintain 15 feet of clearance.
Comment Number: 4 Comment Originated: 11/28/2014
Department: Outside Agencies
Contact: Don Kapperman, ,
Topic: General
12/03/2014: Comcast would like to do joint trench with Ft Collins Light and Power
-Don Kapperman, Don_Kapperman@cable.comcast.com
Comment Number: 1 Comment Originated: 12/03/2014
Department: PFA
Contact: Jim Lynxwiler, 970-416-2869, jlynxwiler@poudre-fire.org
Topic: General
12/03/2014: Prior PFA comments have been noted or resolved. No further comments at this time.
Comment Number: 1 Comment Originated: 12/03/2014
Department: Stormwater Engineering
Contact: Jesse Schlam, 970-218-2932, jschlam@fcgov.com
Topic: Erosion Control
12/01/2014: The site disturbs more than 10,000 sq-ft and in a sensitive area, therefore Erosion and
Sediment Control Materials need to be submitted for FDP. The erosion control requirements are in the
Stormwater Design Criteria under the Amendments of Volume 3 Chapter 7 Section 1.3.3. Current
Erosion Control Materials Submitted does not meet requirements. Please submit; Erosion Control
Plan, Erosion Control Report, and an Escrow / Security Calculation. If you need clarification concerning
this section, or if there are any questions please contact Jesse Schlam 970-218-2932 or email @
jschlam@fcgov.com
Comment Number: 1 Comment Originated: 12/01/2014
Contact: Shane Boyle, 970-221-6339, sboyle@fcgov.com
Topic: General
Page 8 of 15
12/02/2014: Please ensure there is separation between the two different plan sets. Many onsite
improvements are shown on the Aspen Engineering plans and should be shown on the Cole
Engineering plans instead. Examples include onsite LID improvements, drainage basin and
hydrologic calculations, and porous pavement section.
Comment Number: 2 Comment Originated: 12/02/2014
12/02/2014: Please investigate the use of permanent erosion control on the curb cuts into the
detention pond. It is not clear from the detail how the presedimentation basin will function with regards
to handling erosion.
Comment Number: 3 Comment Originated: 12/02/2014
12/02/2014: There are inconsistencies between the drainage report calculations and the pond outlet
detail on Sheet 11 of the Cole Engineering plans. Please review and revise as necessary.
Comment Number: 4 Comment Originated: 12/02/2014
12/02/2014: While the soft pan in the detention pond is appropriate, it does not count towards the LID
site treatment percentage. Please review the treatment percentage without including this section of
soft pan.
Comment Number: 5 Comment Originated: 12/02/2014
12/02/2014: The proposed storm sewer stubouts into undeveloped parcels is not a typical approach
unless it is certain how these parcels will develop. It may be best to not install these stubouts unless
the development of the adjacent parcels is known.
Comment Number: 6 Comment Originated: 12/02/2014
Department: Technical Services
Contact: Jeff County, 970-221-6588, jcounty@fcgov.com
Topic: Building Elevations
12/02/2014: COLE PLANS: All sheets need the title of "Mainstreet Health & Wellness Suites" added.
Comment Number: 1 Comment Originated: 12/02/2014
12/02/2014: COLE PLANS: There are line over text issues. See redlines.
Comment Number: 2 Comment Originated: 12/02/2014
Topic: Construction Drawings
Page 9 of 15
12/02/2014: COLE PLANS: The City has moved to the NAVD88 vertical datum. Please provide the
following information in the format shown below.
If your project is started on NAVD88 datum:
1) PROJECT DATUM: NAVD88
BENCHMARK #1 w/ DESCRIPTION
ELEVATION:
BENCHMARK #2 w/ DESCRIPTION
ELEVATION:
OR, if project has already been surveyed in NAVD29 Unadjusted datum:
2) PROJECT DATUM: NGVD29 UNADJUSTED (OLD CITY OF FORT COLLINS DATUM)
BENCHMARK #1 w/ DESCRIPTION
ELEVATION:
BENCHMARK #2 w/ DESCRIPTION
ELEVATION:
If using NGVD29 UNADJUSTED the following equation statement will be needed.
NOTE: IF NAVD 88 DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION
SHOULD BE USED: NAVD88 = NGVD29 UNADJUSTED + X.XX'
Comment Number: 3 Comment Originated: 12/02/2014
12/02/2014: COLE PLANS: There are line over text issues. See redlines.
Comment Number: 4 Comment Originated: 12/02/2014
12/02/2014: COLE PLANS: All boundary information needs to go on the outside of the boundary
lines. See redlines.
Comment Number: 5 Comment Originated: 12/02/2014
12/02/2014: COLE PLANS: Please remove all linework from signature blocks. See redlines.
Comment Number: 6 Comment Originated: 12/02/2014
12/02/2014: COLE PLANS: There are text over text issues. See redlines.
Comment Number: 7 Comment Originated: 12/02/2014
12/02/2014: COLE PLANS: There is text that needs to be masked. Mask all text in hatched areas.
See redlines.
Comment Number: 8 Comment Originated: 12/02/2014
Page 10 of 15
12/02/2014: ASPEN PLANS: The City has moved to the NAVD88 vertical datum. Please provide the
following information in the format shown below.
If your project is started on NAVD88 datum:
1) PROJECT DATUM: NAVD88
BENCHMARK #1 w/ DESCRIPTION
ELEVATION:
BENCHMARK #2 w/ DESCRIPTION
ELEVATION:
OR, if project has already been surveyed in NAVD29 Unadjusted datum:
2) PROJECT DATUM: NGVD29 UNADJUSTED (OLD CITY OF FORT COLLINS DATUM)
BENCHMARK #1 w/ DESCRIPTION
ELEVATION:
BENCHMARK #2 w/ DESCRIPTION
ELEVATION:
If using NGVD29 UNADJUSTED the following equation statement will be needed.
NOTE: IF NAVD 88 DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION
SHOULD BE USED: NAVD88 = NGVD29 UNADJUSTED + X.XX'
Comment Number: 9 Comment Originated: 12/02/2014
12/02/2014: ASPEN PLANS: Please make sure the reception numbers for the easements by
separate document are added prior to submitting mylars.
Comment Number: 10 Comment Originated: 12/02/2014
12/02/2014: ASPEN PLANS: There is text on sheet 18 that needs to be rotated 180 degrees. See
redlines.
Comment Number: 11 Comment Originated: 12/02/2014
12/02/2014: ASPEN PLANS: Please tie the coordinates on sheet 19 to the Mainstreet Health &
Wellness Suites property boundary.
Comment Number: 12 Comment Originated: 12/02/2014
Topic: Landscape Plans
12/02/2014: CONTEXT PLANS: All sheets need the title of "Mainstreet Health & Wellness Suites"
added.
Comment Number: 13 Comment Originated: 12/02/2014
Page 11 of 15
12/02/2014: CONTEXT PLANS: There are line over text issues. See redlines.
Comment Number: 14 Comment Originated: 12/02/2014
12/02/2014: CONTEXT PLANS: There is text that needs to be masked. Mask all text in hatched areas.
See redlines.
Comment Number: 15 Comment Originated: 12/02/2014
12/02/2014: VIGNETTE PLANS: Please make "Main Street" in the title one word on all streets.
Comment Number: 16 Comment Originated: 12/02/2014
Topic: Lighting Plan
12/02/2014: All sheets need the title of "Mainstreet Health & Wellness Suites" added.
Comment Number: 17 Comment Originated: 12/02/2014
Topic: Plat
12/02/2014: Please make changes to the legal description as marked. See redlines.
Comment Number: 18 Comment Originated: 12/02/2014
12/02/2014: We prefer that the Owner Signature blocks be directly under/following the Repair
Guarantee statement. See redlines.
Comment Number: 19 Comment Originated: 12/02/2014
12/02/2014: Please add the name & title of the lienholder signature.
Comment Number: 20 Comment Originated: 12/02/2014
12/02/2014: Please show the west right of way line of Zielger Road, and label the subdivisions along
the west side. See redlines.
Comment Number: 21 Comment Originated: 12/02/2014
12/02/2014: Please change the right of way width of Ziegler Road, and add additional dedication
information. See redlines.
Comment Number: 22 Comment Originated: 12/02/2014
12/02/2014: Please add new title commitment information as available.
Comment Number: 23 Comment Originated: 12/02/2014
12/02/2014: Please correct the spelling of "Technology". See redlines.
Comment Number: 24 Comment Originated: 12/02/2014
12/02/2014: Please check the name of the Plat to the north of the property & to the east of Technology
Parkway. See redlines.
Comment Number: 25 Comment Originated: 12/02/2014
12/02/2014: To whom is the 15' Private Irrigation Easement & 10' Irrigation Easement for? See
redlines.
Comment Number: 26 Comment Originated: 12/02/2014
12/02/2014: Please make sure the reception numbers for the easements by separate document are
added prior to submitting mylars.
Comment Number: 27 Comment Originated: 12/02/2014
12/02/2014: Please provide dedication information for Technology Parkway & Precision Drive. See
redlines.
Comment Number: 28 Comment Originated: 12/02/2014
Page 12 of 15
12/02/2014: Please provide current acceptable monument records for the aliquot corners shown.
These should be emailed directly to Jeff at jcounty@fcgov.com.
Comment Number: 29 Comment Originated: 12/02/2014
12/02/2014: Please add a "set" symbol as marked along Technology Parkway. See redlines.
Comment Number: 30 Comment Originated: 12/02/2014
12/02/2014: Please size down the "set" symbols shown on sheet 2, to match the legend. See
redlines.
Comment Number: 31 Comment Originated: 12/02/2014
Topic: Site Plan
12/02/2014: Please add a note stating "See sheet 1 for extension of Precision Drive details". See
redlines.
Comment Number: 32 Comment Originated: 12/02/2014
12/02/2014: The benchmark statement is not needed on the Site Plans. If left on they will need to
match the following format.
If your project is started on NAVD88 datum:
1) PROJECT DATUM: NAVD88
BENCHMARK #1 w/ DESCRIPTION
ELEVATION:
BENCHMARK #2 w/ DESCRIPTION
ELEVATION:
OR, if project has already been surveyed in NAVD29 Unadjusted datum:
2) PROJECT DATUM: NGVD29 UNADJUSTED (OLD CITY OF FORT COLLINS DATUM)
BENCHMARK #1 w/ DESCRIPTION
ELEVATION:
BENCHMARK #2 w/ DESCRIPTION
ELEVATION:
If using NGVD29 UNADJUSTED the following equation statement will be needed.
NOTE: IF NAVD 88 DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION
SHOULD BE USED: NAVD88 = NGVD29 UNADJUSTED + X.XX'
Comment Number: 33 Comment Originated: 12/02/2014
12/02/2014: All boundary information needs to go on the outside of the boundary lines. See redlines.
Comment Number: 34 Comment Originated: 12/02/2014
Page 13 of 15
12/02/2014: There are line over text issues. See redlines.
Comment Number: 35 Comment Originated: 12/02/2014
12/02/2014: There is text that needs to be masked. Mask all text in hatched areas. See redlines.
Comment Number: 36 Comment Originated: 12/02/2014
12/02/2014: There are text over text issues. See redlines.
Comment Number: 37 Comment Originated: 12/02/2014
Department: Traffic Operation
Contact: Martina Wilkinson, 970-221-6887, mwilkinson@fcgov.com
Topic: General
12/02/2014: The plans show the Intel access to be 'closed by others'. Both accesses will not be
allowed. What is the timeframe for closure?
Comment Number: 1 Comment Originated: 12/02/2014
12/02/2014: Transportation Planning would like to see a sidewalk connection on the east side of the
property to Precision Drive.
Comment Number: 2 Comment Originated: 12/02/2014
12/02/2014: The internal 'intersection' appears to be a large, slightly offset, uncontrolled intersection.
This may need to be detailed a bit more in later submittals.
Comment Number: 3 Comment Originated: 12/02/2014
Department: Water Conservation
Contact: Eric Olson, 970-221-6704, eolson@fcgov.com
Topic: General
11/10/2014: Irrigation plans are required no later than at the time of building permit. The irrigation plans
must comply with the provisions outlined in Section 3.2.1(J) of the Land Use Code. Direct questions
concerning irrigation requirements to Eric Olson, at 221-6704 or eolson@fcgov.com
Comment Number: 1 Comment Originated: 11/10/2014
Department: Water-Wastewater Engineering
Contact: Shane Boyle, 970-221-6339, sboyle@fcgov.com
Topic: General
12/02/2014: The minimum separation distance between water services and gas or electric services is
10'. As shown, the distance between the water service and gas service does not appear to meet this
criteria. Please review and revise accordingly.
Comment Number: 1 Comment Originated: 12/02/2014
12/02/2014: The fire hydrant relocation at the north end of the site will need to be completed with this
project unless it is done ahead of time. Please indicate who will be doing this work and when if it is
done by others. Details will need to be provided for this work.
Comment Number: 2 Comment Originated: 12/02/2014
Page 14 of 15
12/02/2014: The 12" main that currently dead ends at the northwest corner of the site was originally
intended to connect to the main in the street that was originally planned along the northern property
boundary. Since this road has been moved, the main will either need to continue through the site and
tie into the main in Precision Drive or be connected to the main in Ziegler Road. That work will need to
be completed with this project.
Comment Number: 3 Comment Originated: 12/02/2014
12/02/2014: A separate meter pit will be required for the domestic service and irrigation service. The
plans currently show only one meter pit.
Comment Number: 4 Comment Originated: 12/02/2014
12/02/2014: Per City standards, underdrains will be needed under the proposed permeable paver
sections.
Comment Number: 5 Comment Originated: 12/02/2014
12/02/2014: A 4" meter seems to be larger than needed for the projected water usage. Please
review and confirm the meter pit needs to be this large.
Comment Number: 6 Comment Originated: 12/02/2014
12/02/2014: Please include standard City details in the Cole Civil Engineering plan set for all work
associated with the onsite improvements.
Comment Number: 7 Comment Originated: 12/02/2014
Page 15 of 15