HomeMy WebLinkAboutMAINSTREET HEALTH & WELLNESS SUITES - PDP - PDP140018 - CORRESPONDENCE -Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov.com/developmentreview December 05, 2014 Eric Morff COLE & ASSOCIATES, INC. 401 S 18TH STREET SUITE 200 St. Louis, MO 63103 Comment Summary: Department: Planning Services Contact: Noah Beals, 970-416-2313, nbeals@fcgov.com Topic: General 12/02/2014: The lighting plan will need to include catalog cut-sheets of the fixtures. Comment Number: 1 Comment Originated: 12/02/2014 12/02/2014: On the cover sheet of the Planning set please change the Director of Planning signature block to match the Director of Community Development and Neighborhood Services signature block found on the Plat. Comment Number: 2 Comment Originated: 12/02/2014 12/02/2014: On the Cover sheet the index will need to include all the sheets that are not in the utility plans or plat, i.e. landscape, lighting plan. Comment Number: 3 Comment Originated: 12/02/2014 12/02/2014: Why is the public sidewalk set back 2 feet from the property line? Comment Number: 4 Comment Originated: 12/02/2014 12/02/2014: Land Use Code (LUC) Section 3.2.2(C)(5)(b) Requires walkways on both sides of the drive aisle. The access on from Ziegler Road shows only an attached sidewalk along the south side of the drive aisle. This sidewalk goes straight into the ramp of the sidewalk. Detach the sidewalk from the drive aisle and provide it on both sides of the drive aisle. The sidewalk on the north side should curve to meet the north adjoining property. Comment Number: 5 Comment Originated: 12/02/2014 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Noah Beals, at 970-416-2313 or nbeals@fcgov.com. RE: Mainstreet Health & Wellness Suites, PDP140018, Round Number 1 Page 1 of 15 12/02/2014: A sidewalk connection is needed along the west side of the drive aisle that connects to precision drive. This should be detached from the drive aisle and connect into the internal sidewalk system. Comment Number: 6 Comment Originated: 12/02/2014 12/02/2014: The off-street parking spaces do not add up to 96 total spaces as indicated on the cover sheet. The on street parking spaces are not to be included. Comment Number: 7 Comment Originated: 12/02/2014 12/02/2014: The sidwalkway system in the landscape islands do align. These need to be aligned The sidewalk system on the landscape plan does not match that of the site plan. Comment Number: 8 Comment Originated: 12/02/2014 12/02/2014: Parking stalls cannot exceed 15 in a row. An landscape island is required every 15 spaces. Comment Number: 9 Comment Originated: 12/02/2014 12/02/2014: The Planting schedule will need to include quantities. The street trees need more diversity. Please do not use on specie along the entire right-of-way. Comment Number: 10 Comment Originated: 12/02/2014 12/02/2014: The Alternative compliance request to the build-to line along should include trees on both sides of the public side walk. Also are the outdoor patio's for employee use? If not is there an outdoor area designated for employees? Comment Number: 11 Comment Originated: 12/02/2014 12/02/2014: The site plan labels the the water quality pond as a retention pond, is this correct or is it a detention pond? Why is the pond sparse in landscaping? Comment Number: 12 Comment Originated: 12/02/2014 12/02/2014: The elevations need to show the height of the building to the tallest point. It appears the building may be over 40 ft in height? If so further analysis will need t to be provided. Comment Number: 13 Comment Originated: 12/02/2014 12/02/2014: The elevation 3-d perspective does not match the other elevation drawings. Can you provide 1 color copy of the elevations? It is difficult to read the articulation and in the building and the materials. Comment Number: 14 Comment Originated: 12/02/2014 Department: Engineering Development Review Contact: Marc Virata, 970-221-6567, mvirata@fcgov.com Topic: Construction Drawings 12/03/2014: 1" = 60' isn't allowed for plan view (and profile view) per LCUASS 3.2.7. The 60 scale on sheet 18 would need to be modified. In general, even though 50 scale is allowed in this standard, I'm concerned that the information being provided in 50 scale will be difficult to read when the information required with a final plan submittal is then added. The road plan and profile information should ideally then be provided at a 30 or 40 scale. Comment Number: 11 Comment Originated: 12/03/2014 Page 2 of 15 12/03/2014: The grading plan is not showing the property boundary. Comment Number: 12 Comment Originated: 12/03/2014 12/03/2014: For final on the Precision Drive plan and profile, please ensure that flowline sump conditions of .5% do not utilize a vertical curves. Comment Number: 13 Comment Originated: 12/03/2014 Topic: General 12/03/2014: The plans indicate references to various work being done either by "owner" or "by others". These references should be removed as the work being done is considered required by the developer in conjunction with the project and the City won't make a distinction between different parties. My presumption is that Precision Drive will be constructed from Technology Parkway to Ziegler Road with the development plan. Comment Number: 2 Comment Originated: 12/03/2014 12/03/2014: In general, the plans need to show what infrastructure is to be fully built with the project in bold, with the existing condition faded. The site and civil plans for instance should show Precision Drive not in an existing lineweight, but proposed. On the site and landscape plans, Precision Drive should be shown connecting to Technology Parkway. Comment Number: 3 Comment Originated: 12/03/2014 12/03/2014: The plans need to depict how the Intel property to the north will change with the closure of the driveway abutting the property. Show the addition of curb and gutter and removal of the driveway approach, indicate what landscaping is to be added, etc. Comment Number: 4 Comment Originated: 12/03/2014 12/03/2014: There appears to be some grading for Precision Drive that falls outside of the Precision Drive right-of-way on the south side. Additionally there appears to be some utility and potentially drainage work that falls outside of right-of-way and outside of the future utility easement. There may be some benefits in having the plat also included the two unplatted properties east and south of the proposed development, as this would allow easements that are needed offsite of the actual development to be provided via the plat. In general, an understanding of what work is occurring outside of the property, right-of-way, and/or an easement needs to be understood at this time. There's two proposed storm sewer for outfall on the south side of Precision Drive that would seem to need easements established onto that property. Comment Number: 5 Comment Originated: 12/03/2014 Topic: Landscape Plans 12/03/2014: The Landscape plan doesn't show the curb returns for Precision Drive intersecting Ziegler Road. I suspect that the indication of the curb returns might conflict with the street tree furthest south along Ziegler Road and may need to be adjusted accordingly. Comment Number: 14 Comment Originated: 12/03/2014 Topic: Plat 12/03/2014: The Ziegler Road right-of-way needs to show what the existing right-of-way is for the full width of the road for verification that the amount of right-of-way abutting the property is in conformance with City requirements. Comment Number: 6 Comment Originated: 12/03/2014 12/03/2014: Right-of-way for Precision Drive should not have the irrigation easement shown crossing the right-of-way, the pipe crossing will then be permitted through an encroachment permit. Comment Number: 7 Comment Originated: 12/03/2014 Page 3 of 15 12/03/2014: The plat needs to show an access easement from the Intel access being tied into, out to the driveway that connects out to Ziegler to ensure that shared access can be maintained onto this property. Comment Number: 8 Comment Originated: 12/03/2014 12/03/2014: Who is the party that would need to sign the plat and plans for the private irrigation easement? In general there should be some description on the intent of the private irrigation easement that differentiates it from the "Easements" indicated in the "Certificate of Dedication". (The Aspen civil set has a signature block for Poudre School District, might this be the party that would need to sign?) The signature for the party should be on the plat and the civil cover sheet (Cole). Comment Number: 9 Comment Originated: 12/03/2014 12/03/2014: Irrigation pipe cover over Precision Drive is substandard with 2.5 feet of cover. Additional cover is needed. Comment Number: 10 Comment Originated: 12/03/2014 Contact: Sheri Langenberger, 970-221-6573, slangenberger@fcgov.com Topic: General 11/07/2014: The Transporation Development Review Fee (TDRF) amount that was paid was not correctly calculated and the actual amount owed for the PDP application was less than what you paid. I have requested a refund of $5,977.75 be processed. The total amount that was due based on current building square footage and area being platted is: $21,763.50 Comment Number: 1 Comment Originated: 11/07/2014 Department: Forestry Contact: Tim Buchanan, 970-221-6361, tbuchanan@fcgov.com Topic: Landscape Plans 12/03/2014: The following comments pertain only to trees and tree related issues on the proposal. Comment Number: 1 Comment Originated: 12/03/2014 12/03/2014: The street tree design for species variation by grouping of different species within rows should follow the standards in the Larimer County Urban Area Street standards appendix C, Streetscape Standards Fort Collins section 4.1.1 titled Species Groupings within Tree Rows. Street tree selection should be from the City of Fort Collins Street Tree List. Comment Number: 2 Comment Originated: 12/03/2014 12/03/2014: List quantities of trees used in the Plant schedule and the percentage of each tree species use. Minimum tree species diversity should be followed as described in LUC 3.2.1 D 3. Comment Number: 3 Comment Originated: 12/03/2014 12/03/2014: The first street tree on Ziegler just north of Precisions is close to the corner an could cause sight visibility problems. Evaluate for deletion. Comment Number: 4 Comment Originated: 12/03/2014 Page 4 of 15 12/03/2014: Show locations of street lights and space canopy and ornamental trees away from any street lights to meet the LUC standard 3.2.1 K 1. If there are street lights by the main facility design ornamental trees within 15 feet of the light and use canopy shade trees in all other parkway locations. This would be similar to the street tree design shown on Precision Drive on landscape sheet 2 of 2. Comment Number: 5 Comment Originated: 12/03/2014 12/03/2014: Please add these street tree notes under a separate heading labeled Street Tree Notes. 1. A permit must be obtained from the City Forester before any trees or shrubs as noted on this plan are planted, pruned or removed on the public right-of-way. This includes zones between the sidewalk and curb, medians and other City property. This permit shall approve the location and species to be planted. Failure to obtain this permit may result in replacing or relocating trees and a hold on certificate of occupancy. 2. Contact the City Forester to inspect all street tree plantings at the completion of each phase of the development. All trees need to have been installed as shown on the landscape plan. Approval of street tree planting is required before final approval of each phase. 3. Street tree shall be supplied and planted by the developer using a qualified landscape contractor. 4. The developer shall replace all dead and dying street trees after planting until final maintenance inspection and acceptance by the City of Fort Collins Forestry Division. All street trees in the project must be established of an approved species and of acceptable condition prior to acceptance. 5. Street tree locations and numbers may be adjusted to accommodate driveway locations, utility standards, separation between trees, street signs and street lights. Street trees shall be centered in the middle of the parkway. Quantities shown on plan must be installed unless a reduction occurs to meet separation standards. Comment Number: 6 Comment Originated: 12/03/2014 12/03/2014: Please place the following note on the landscape plan in larger bold print with a bold border around the note. A free permit must be obtained from the City Forester before any street trees are planted in parkways between the sidewalk and Curb. Street tree locations and numbers may change to meet actual utility/tree separation standards. Landscape contractor must obtain approval of street tree location after utility locates. Street trees must be inspected and approved before planting. Failure to obtain this permit is a violation of the Code of the City of Fort Collins. Comment Number: 7 Comment Originated: 12/03/2014 Page 5 of 15 12/03/2014: Tree species selection: 1. Please change Celebration Maple to another canopy shade tree. Celebration Maple and other hybrids between Silver Maple and Red Maple are not adapted to the soils in the Fort Collins area and do not survive and thrive long term. 2. The two ornamental trees shown on the plan are not typically used wide scale as ornamental trees on local projects. These include Saskatoon Serviceberry and Rocky Mountain Birch. The native serviceberry is actually a large shrub. The following are some good ornamental trees often used by designers that should be considered for use on the project the provide variation in tree form and ornamental interest. Radiant Crabapple Chanticleer Pear Hotwings Tatarian Maple Thunderchild Crabapple Spring Snow Crab apple Ivory Silk Tree Lilac 3. Austrian Pine would be a better adapted conifer tree to the area than Limber Pine. 4. Please label the Bur Oak as Bullet Gall Resistant by putting that statement by the common name. Comment Number: 8 Comment Originated: 12/03/2014 12/03/2014: Review the full tree stocking standard in LUC 3.2.1 1 c and evaluate the need to add additional trees on high visibility and use sides of the building. Comment Number: 9 Comment Originated: 12/03/2014 12/03/2014: Review the Parking Lot Interior Landscaping standards found in LUC 3.2.1 5. Evaluate the need to add additional trees to the long parking lot island north of the building. Comment Number: 10 Comment Originated: 12/03/2014 12/03/2014: Additional landscape notes: The following plant notes or equivalent should be added to the General Landscape and Planting Notes found on sheet L1 of 4. Please add these notes that are found on the landscape plan for Precision Drive that are on sheet 1 of 2. 2,6,7,8,11,12,13,17,20 Comment Number: 11 Comment Originated: 12/03/2014 Department: Internal Services Contact: Russell Hovland, 970-416-2341, rhovland@fcgov.com Topic: Building Insp Plan Review Page 6 of 15 12/03/2014: Building Permit Pre-Submittal Meeting Pre-Submittal meetings are offered to assist the designer/builder by assuring, early on in the design, that the new commercial or multi-family projects are on track to complying with all of the adopted City codes and Standards listed below. The proposed project should be in the early to mid-design stage for this meeting to be effective and is typically scheduled after the Current Planning conceptual review meeting. Applicants of new commercial or multi-family projects are advised to call 416-2341 to schedule a pre-submittal meeting. Applicants should be prepared to present site plans, floor plans, and elevations and be able to discuss code issues of occupancy, square footage and type of construction being proposed. Construction shall comply with the following adopted codes as amended: 2012 International Building Code (IBC) 2012 International Residential Code (IRC) 2012 International Energy Conservation Code (IECC) 2012 International Mechanical Code (IMC) 2012 International Fuel Gas Code (IFGC) 2012 International Plumbing Code (IPC) as amended by the State of Colorado 2014 National Electrical Code (NEC) as amended by the State of Colorado Accessibility: State Law CRS 9-5 & ICC/ANSI A117.1-2009. Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF. Frost Depth: 30 inches. Wind Load: 100- MPH 3 Second Gust Exposure B. Seismic Design: Category B. Climate Zone: Zone 5 Energy Code Use 1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC. 2. Multi-family and Condominiums 3 stories max: 2012 IECC residential chapter. 3. Commercial and Multi-family 4 stories and taller: 2012 IECC commercial chapter. Comment Number: 2 Comment Originated: 12/03/2014 Contact: Todd Reidenbach, , Topic: General 11/26/2014: Addresses will be assigned by the GIS Department after the plans have met final approval through Development Review and are recorded with the City Todd Reidenbach, GISP GIS Mapping Specialist treidenbach@fcgov.com 970.416.2483 Work 970.221.6329 Fax Comment Number: 1 Comment Originated: 11/26/2014 Department: Light And Power Contact: Justin Fields, 970-224-6150, jfields@fcgov.com Topic: General Page 7 of 15 11/28/2014: Electric development and system modification charges will apply. An online estimator for these charges is available at http://www.fcgov.com/utilities/business/builders-and-developers/plant-investment-development-fees/el ectric-development-fee-estimator?id=3. Comment Number: 1 Comment Originated: 11/28/2014 11/28/2014: The transformer and meter locations need to be coordinated with Light and Power Engineering, 970-221-6700. Comment Number: 2 Comment Originated: 11/28/2014 11/28/2014: A C-1 form and one-line diagram need to submitted to Light and Power Engineering. The C-1 form is available at http://www.fcgov.com/utilities/img/site_specific/uploads/c-1_form.pdf. Comment Number: 3 Comment Originated: 11/28/2014 11/28/2014: Contact Light and Power Engineering for a layout of the streetlights along Ziegler and adjust the street trees accordingly. Shade trees need to maintain 40 feet of clearance with streetlights and ornamental trees need to maintain 15 feet of clearance. Comment Number: 4 Comment Originated: 11/28/2014 Department: Outside Agencies Contact: Don Kapperman, , Topic: General 12/03/2014: Comcast would like to do joint trench with Ft Collins Light and Power -Don Kapperman, Don_Kapperman@cable.comcast.com Comment Number: 1 Comment Originated: 12/03/2014 Department: PFA Contact: Jim Lynxwiler, 970-416-2869, jlynxwiler@poudre-fire.org Topic: General 12/03/2014: Prior PFA comments have been noted or resolved. No further comments at this time. Comment Number: 1 Comment Originated: 12/03/2014 Department: Stormwater Engineering Contact: Jesse Schlam, 970-218-2932, jschlam@fcgov.com Topic: Erosion Control 12/01/2014: The site disturbs more than 10,000 sq-ft and in a sensitive area, therefore Erosion and Sediment Control Materials need to be submitted for FDP. The erosion control requirements are in the Stormwater Design Criteria under the Amendments of Volume 3 Chapter 7 Section 1.3.3. Current Erosion Control Materials Submitted does not meet requirements. Please submit; Erosion Control Plan, Erosion Control Report, and an Escrow / Security Calculation. If you need clarification concerning this section, or if there are any questions please contact Jesse Schlam 970-218-2932 or email @ jschlam@fcgov.com Comment Number: 1 Comment Originated: 12/01/2014 Contact: Shane Boyle, 970-221-6339, sboyle@fcgov.com Topic: General Page 8 of 15 12/02/2014: Please ensure there is separation between the two different plan sets. Many onsite improvements are shown on the Aspen Engineering plans and should be shown on the Cole Engineering plans instead. Examples include onsite LID improvements, drainage basin and hydrologic calculations, and porous pavement section. Comment Number: 2 Comment Originated: 12/02/2014 12/02/2014: Please investigate the use of permanent erosion control on the curb cuts into the detention pond. It is not clear from the detail how the presedimentation basin will function with regards to handling erosion. Comment Number: 3 Comment Originated: 12/02/2014 12/02/2014: There are inconsistencies between the drainage report calculations and the pond outlet detail on Sheet 11 of the Cole Engineering plans. Please review and revise as necessary. Comment Number: 4 Comment Originated: 12/02/2014 12/02/2014: While the soft pan in the detention pond is appropriate, it does not count towards the LID site treatment percentage. Please review the treatment percentage without including this section of soft pan. Comment Number: 5 Comment Originated: 12/02/2014 12/02/2014: The proposed storm sewer stubouts into undeveloped parcels is not a typical approach unless it is certain how these parcels will develop. It may be best to not install these stubouts unless the development of the adjacent parcels is known. Comment Number: 6 Comment Originated: 12/02/2014 Department: Technical Services Contact: Jeff County, 970-221-6588, jcounty@fcgov.com Topic: Building Elevations 12/02/2014: COLE PLANS: All sheets need the title of "Mainstreet Health & Wellness Suites" added. Comment Number: 1 Comment Originated: 12/02/2014 12/02/2014: COLE PLANS: There are line over text issues. See redlines. Comment Number: 2 Comment Originated: 12/02/2014 Topic: Construction Drawings Page 9 of 15 12/02/2014: COLE PLANS: The City has moved to the NAVD88 vertical datum. Please provide the following information in the format shown below. If your project is started on NAVD88 datum: 1) PROJECT DATUM: NAVD88 BENCHMARK #1 w/ DESCRIPTION ELEVATION: BENCHMARK #2 w/ DESCRIPTION ELEVATION: OR, if project has already been surveyed in NAVD29 Unadjusted datum: 2) PROJECT DATUM: NGVD29 UNADJUSTED (OLD CITY OF FORT COLLINS DATUM) BENCHMARK #1 w/ DESCRIPTION ELEVATION: BENCHMARK #2 w/ DESCRIPTION ELEVATION: If using NGVD29 UNADJUSTED the following equation statement will be needed. NOTE: IF NAVD 88 DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NAVD88 = NGVD29 UNADJUSTED + X.XX' Comment Number: 3 Comment Originated: 12/02/2014 12/02/2014: COLE PLANS: There are line over text issues. See redlines. Comment Number: 4 Comment Originated: 12/02/2014 12/02/2014: COLE PLANS: All boundary information needs to go on the outside of the boundary lines. See redlines. Comment Number: 5 Comment Originated: 12/02/2014 12/02/2014: COLE PLANS: Please remove all linework from signature blocks. See redlines. Comment Number: 6 Comment Originated: 12/02/2014 12/02/2014: COLE PLANS: There are text over text issues. See redlines. Comment Number: 7 Comment Originated: 12/02/2014 12/02/2014: COLE PLANS: There is text that needs to be masked. Mask all text in hatched areas. See redlines. Comment Number: 8 Comment Originated: 12/02/2014 Page 10 of 15 12/02/2014: ASPEN PLANS: The City has moved to the NAVD88 vertical datum. Please provide the following information in the format shown below. If your project is started on NAVD88 datum: 1) PROJECT DATUM: NAVD88 BENCHMARK #1 w/ DESCRIPTION ELEVATION: BENCHMARK #2 w/ DESCRIPTION ELEVATION: OR, if project has already been surveyed in NAVD29 Unadjusted datum: 2) PROJECT DATUM: NGVD29 UNADJUSTED (OLD CITY OF FORT COLLINS DATUM) BENCHMARK #1 w/ DESCRIPTION ELEVATION: BENCHMARK #2 w/ DESCRIPTION ELEVATION: If using NGVD29 UNADJUSTED the following equation statement will be needed. NOTE: IF NAVD 88 DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NAVD88 = NGVD29 UNADJUSTED + X.XX' Comment Number: 9 Comment Originated: 12/02/2014 12/02/2014: ASPEN PLANS: Please make sure the reception numbers for the easements by separate document are added prior to submitting mylars. Comment Number: 10 Comment Originated: 12/02/2014 12/02/2014: ASPEN PLANS: There is text on sheet 18 that needs to be rotated 180 degrees. See redlines. Comment Number: 11 Comment Originated: 12/02/2014 12/02/2014: ASPEN PLANS: Please tie the coordinates on sheet 19 to the Mainstreet Health & Wellness Suites property boundary. Comment Number: 12 Comment Originated: 12/02/2014 Topic: Landscape Plans 12/02/2014: CONTEXT PLANS: All sheets need the title of "Mainstreet Health & Wellness Suites" added. Comment Number: 13 Comment Originated: 12/02/2014 Page 11 of 15 12/02/2014: CONTEXT PLANS: There are line over text issues. See redlines. Comment Number: 14 Comment Originated: 12/02/2014 12/02/2014: CONTEXT PLANS: There is text that needs to be masked. Mask all text in hatched areas. See redlines. Comment Number: 15 Comment Originated: 12/02/2014 12/02/2014: VIGNETTE PLANS: Please make "Main Street" in the title one word on all streets. Comment Number: 16 Comment Originated: 12/02/2014 Topic: Lighting Plan 12/02/2014: All sheets need the title of "Mainstreet Health & Wellness Suites" added. Comment Number: 17 Comment Originated: 12/02/2014 Topic: Plat 12/02/2014: Please make changes to the legal description as marked. See redlines. Comment Number: 18 Comment Originated: 12/02/2014 12/02/2014: We prefer that the Owner Signature blocks be directly under/following the Repair Guarantee statement. See redlines. Comment Number: 19 Comment Originated: 12/02/2014 12/02/2014: Please add the name & title of the lienholder signature. Comment Number: 20 Comment Originated: 12/02/2014 12/02/2014: Please show the west right of way line of Zielger Road, and label the subdivisions along the west side. See redlines. Comment Number: 21 Comment Originated: 12/02/2014 12/02/2014: Please change the right of way width of Ziegler Road, and add additional dedication information. See redlines. Comment Number: 22 Comment Originated: 12/02/2014 12/02/2014: Please add new title commitment information as available. Comment Number: 23 Comment Originated: 12/02/2014 12/02/2014: Please correct the spelling of "Technology". See redlines. Comment Number: 24 Comment Originated: 12/02/2014 12/02/2014: Please check the name of the Plat to the north of the property & to the east of Technology Parkway. See redlines. Comment Number: 25 Comment Originated: 12/02/2014 12/02/2014: To whom is the 15' Private Irrigation Easement & 10' Irrigation Easement for? See redlines. Comment Number: 26 Comment Originated: 12/02/2014 12/02/2014: Please make sure the reception numbers for the easements by separate document are added prior to submitting mylars. Comment Number: 27 Comment Originated: 12/02/2014 12/02/2014: Please provide dedication information for Technology Parkway & Precision Drive. See redlines. Comment Number: 28 Comment Originated: 12/02/2014 Page 12 of 15 12/02/2014: Please provide current acceptable monument records for the aliquot corners shown. These should be emailed directly to Jeff at jcounty@fcgov.com. Comment Number: 29 Comment Originated: 12/02/2014 12/02/2014: Please add a "set" symbol as marked along Technology Parkway. See redlines. Comment Number: 30 Comment Originated: 12/02/2014 12/02/2014: Please size down the "set" symbols shown on sheet 2, to match the legend. See redlines. Comment Number: 31 Comment Originated: 12/02/2014 Topic: Site Plan 12/02/2014: Please add a note stating "See sheet 1 for extension of Precision Drive details". See redlines. Comment Number: 32 Comment Originated: 12/02/2014 12/02/2014: The benchmark statement is not needed on the Site Plans. If left on they will need to match the following format. If your project is started on NAVD88 datum: 1) PROJECT DATUM: NAVD88 BENCHMARK #1 w/ DESCRIPTION ELEVATION: BENCHMARK #2 w/ DESCRIPTION ELEVATION: OR, if project has already been surveyed in NAVD29 Unadjusted datum: 2) PROJECT DATUM: NGVD29 UNADJUSTED (OLD CITY OF FORT COLLINS DATUM) BENCHMARK #1 w/ DESCRIPTION ELEVATION: BENCHMARK #2 w/ DESCRIPTION ELEVATION: If using NGVD29 UNADJUSTED the following equation statement will be needed. NOTE: IF NAVD 88 DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NAVD88 = NGVD29 UNADJUSTED + X.XX' Comment Number: 33 Comment Originated: 12/02/2014 12/02/2014: All boundary information needs to go on the outside of the boundary lines. See redlines. Comment Number: 34 Comment Originated: 12/02/2014 Page 13 of 15 12/02/2014: There are line over text issues. See redlines. Comment Number: 35 Comment Originated: 12/02/2014 12/02/2014: There is text that needs to be masked. Mask all text in hatched areas. See redlines. Comment Number: 36 Comment Originated: 12/02/2014 12/02/2014: There are text over text issues. See redlines. Comment Number: 37 Comment Originated: 12/02/2014 Department: Traffic Operation Contact: Martina Wilkinson, 970-221-6887, mwilkinson@fcgov.com Topic: General 12/02/2014: The plans show the Intel access to be 'closed by others'. Both accesses will not be allowed. What is the timeframe for closure? Comment Number: 1 Comment Originated: 12/02/2014 12/02/2014: Transportation Planning would like to see a sidewalk connection on the east side of the property to Precision Drive. Comment Number: 2 Comment Originated: 12/02/2014 12/02/2014: The internal 'intersection' appears to be a large, slightly offset, uncontrolled intersection. This may need to be detailed a bit more in later submittals. Comment Number: 3 Comment Originated: 12/02/2014 Department: Water Conservation Contact: Eric Olson, 970-221-6704, eolson@fcgov.com Topic: General 11/10/2014: Irrigation plans are required no later than at the time of building permit. The irrigation plans must comply with the provisions outlined in Section 3.2.1(J) of the Land Use Code. Direct questions concerning irrigation requirements to Eric Olson, at 221-6704 or eolson@fcgov.com Comment Number: 1 Comment Originated: 11/10/2014 Department: Water-Wastewater Engineering Contact: Shane Boyle, 970-221-6339, sboyle@fcgov.com Topic: General 12/02/2014: The minimum separation distance between water services and gas or electric services is 10'. As shown, the distance between the water service and gas service does not appear to meet this criteria. Please review and revise accordingly. Comment Number: 1 Comment Originated: 12/02/2014 12/02/2014: The fire hydrant relocation at the north end of the site will need to be completed with this project unless it is done ahead of time. Please indicate who will be doing this work and when if it is done by others. Details will need to be provided for this work. Comment Number: 2 Comment Originated: 12/02/2014 Page 14 of 15 12/02/2014: The 12" main that currently dead ends at the northwest corner of the site was originally intended to connect to the main in the street that was originally planned along the northern property boundary. Since this road has been moved, the main will either need to continue through the site and tie into the main in Precision Drive or be connected to the main in Ziegler Road. That work will need to be completed with this project. Comment Number: 3 Comment Originated: 12/02/2014 12/02/2014: A separate meter pit will be required for the domestic service and irrigation service. The plans currently show only one meter pit. Comment Number: 4 Comment Originated: 12/02/2014 12/02/2014: Per City standards, underdrains will be needed under the proposed permeable paver sections. Comment Number: 5 Comment Originated: 12/02/2014 12/02/2014: A 4" meter seems to be larger than needed for the projected water usage. Please review and confirm the meter pit needs to be this large. Comment Number: 6 Comment Originated: 12/02/2014 12/02/2014: Please include standard City details in the Cole Civil Engineering plan set for all work associated with the onsite improvements. Comment Number: 7 Comment Originated: 12/02/2014 Page 15 of 15