Loading...
HomeMy WebLinkAbout626 S. WHITCOMB FOUR-PLEX - PDP/FDP - FDP140023 - SUBMITTAL DOCUMENTS - ROUND 2 - UTILITY PLANS (8)SCALE: 1" = 10'-0" NORTH PORCH PROPOSED DUPLEX ADDITION EXISTING LAWN EXISTING LAWN GRADING PLAN 2 2 (EX.) CONCRETE DRIVE TO REMAIN 5005(E) FINISH FLOOR = 5009.00 = 100'-0" EXISTING ONE STORY DUPLEX WITH BASEMENT FINISH FLOOR = 5008.58 97'-05/8" EXISTING CONCRETE PAN PROPOSED 4'-6" WIDE CONCRETE WALK PROPOSED 4" PVC PERMEABLE PAVEMENT BASE DISCHARGE LINE 5005(P) 5004(P) PROPOSED PERMEABLE PAVEMENT PAVEMENT PROPOSED CURB HIGH PIPE OUTLET PROPOSED 18" Dia. Pipe Riser (EX.) CONCRETE DRIVE TO REMAIN (EX.) CONCRETE WALK TO REMAIN (EX.) CONCRETE WALK TO REMAIN PROPOSED CONCRETE PAVER RETAINER-FLUSH WITH PAVEMENT PROPOSED ASPHALT FINES CRUSHER PATIO FINES CRUSHER PATIO & WALK PROPOSED BIKE STORAGE FIN FLR=5006.05= CONCRETE PAVER RETAINER SCALE: 1" = 10'-0" NORTH PROPOSED DUPLEX ADDITION DRAINAGE & EROSION CONTROL PLAN 2 1 5005(E) FINISH FLOOR = 5009.00 = 100'-0" EXISTING ONE STORY DUPLEX WITH BASEMENT FINISH FLOOR = 5008.58 97'-05/8" EXISTING CONCRETE PAN PROPOSED 4'-6" WIDE CONCRETE WALK 5005(P) 5004(P) PROPOSED PERMEABLE PAVEMENT PAVEMENT SCL SCL SCL WATTLE APPLICATION WATTLE APPLICATION CONCRETE WASHOUT AREA CWA SCL SCL PROPOSED ASPHALT FINES CRUSHER PATIO FINES CRUSHER PATIO & WALK PROPOSED BIKE STORAGE FIN FLR=5006.05= 4 OF 5 DA KGL GRADING, DRAINAGE & EROSION CONTROL SHEET JOB DRAWN DATE CHECKED REVISIONS DRAWING 422 EAST OAK FT COLLINS, COLORADO 80524 (970) 484-0306 ARCHITECTURAL ENGINEERS, LLC ANDERSON ASSOCIATES AA Proposed Duplex Addition to Existing @ 626 S. Whitcomb Street Fort Collins, Colorado 80524 Rodney & Jamie Rice- Owners Dennis R. Messner, P.E. Consulting Civil Engineer 1355 N. Cleveland Ave, Ste. #1 Loveland, CO. 80527 Telephone: (970) 461-3501 Mobile: (970) 402-4360 E-mail: dennis@messnereng.com PLANS 30 JANUARY, 2015 City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: City Engineer Date CHECKED BY: Water & Wastewater Utility Date CHECKED BY: Stormwater Utility Date CALL UTILITY NOTIFICATION CENTER OF COLORADO ÄÄÄ  CALL 2- BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CROSS SECTION A-A PROPERTY LINE 4'-6" CONCRETE SIDEWALK @ 1/4" PER FT. EARTHEN BERM N.T.S. PIPE OUTLET PLAN N.T.S. 4" PVC PIPE EXISTING VERT. CURB & GUTTER PIPE OUTLET SECTION N.T.S. = Inv. 4" PVC PIPE 18" DIA. PIPE RISER N.T.S. = Inv. 4" PVC PIPE = Inv. 4" PVC PIPE Concrete Pipe B A 0.118 2 1 0.075 3 0.024