HomeMy WebLinkAboutSIGMA PHI EPSILON RENOVATION & ADDITION - FDP - FDP150008 - SUBMITTAL DOCUMENTS - ROUND 1 - CORRESPONDENCE-CONCEPTUAL REVIEWPage 1 of 9
318 East Oak Street, Fort Collins, CO 80524 + 1531 West 29th Street, Loveland, CO 80538
970.493.1220 + 970.624.6995 + 303.996.3000 + 888.698.7897
Conceptual Review Response Letter (addressing January 21st, 2015 Comments)
Sigma Phi Epsilon Fraternity House
121 East Lake Street
Fort Collins, CO 80524
Comment Summary:
Department: Planning Services
Contact: Ryan Mounce, 970‐224‐6186, rmounce@fcgov.com
Topic: General
Comment Number: 1 Comment Originated 01/21/2015
01/21/2015: Building Height: On sheet A001, please add the height of the proposed addition to the
building/site information box in addition to existing height.
Comment #1 Response: Heights added to sheet A001.
On the elevations, please measure and show the building height to the top of the roof.
Comment #1 Response: Building roof heights added to elevation sheets 301, 302, 303, & 304.
As the addition also includes a partial 3rd‐story element, we would consider this a 2.5 story addition
requiring another modification of standard. Please submit an additional modification request and
narrative for the building height exceeding the zone district maximum of 2 stories.
Comment #1 Response: Modification of Standard request narrative for building height was submitted
on January 29.
Comment Number: 2 Comment Originated: 01/21/2015
01/21/2015: The landscape plan shows a new bicycle parking area on the west near the alley, but
nothing is shown on the site plan ‐‐ please show this on the site plan as well if any bicycle parking is
actually planned in this location.
Comment #2 Response: Bicycle parking areas have been coordinated between plans.
Comment Number: 3 Comment Originated: 01/21/2015
01/21/2015: The landscape plan could benefit from additional labels/information for each tree. Please
see Forestry notes and identify tree species, size, and if it is to be protected (if an existing tree). If there
is inadequate space for this on the landscape plan, consider a plant table with the same information.
Tree Number, Tree Species, Tree Size, Existing or Proposed, Mitigation value (if existing) and if any trees
are proposed to be removed. In addition, please label the existing grass lawn.
Comment #3 Response: Tree information provided on sheet L101.
Comment Number: 4 Comment Originated: 01/21/2015
Page 2 of 9
318 East Oak Street, Fort Collins, CO 80524 + 1531 West 29th Street, Loveland, CO 80538
970.493.1220 + 970.624.6995 + 303.996.3000 + 888.698.7897
01/21/2015: Prior to the public hearing, please provide a brief, signed letter describing the new lease
agreement executed to preserve the nonconforming use designation at the property.
Comment #4 Response: Lease agreement already submitted.
Comment Number: 5 Comment Originated: 01/21/2015
01/21/2015: On the site plan, please label the material at the southwest corner of the site (asphalt or
concrete?) and if it is new or existing.
Comment #5 Response: Material noted on sheet A001.
Department: Engineering Development Review
Contact: Marc Ragasa, 970.221.6603, mragasa@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 01/20/2015
01/20/2015: Please add the City of Fort Collins signature block to sheet C1.0
Comment #1 Response: Signature block added to sheet C1.0.
Comment Number: 2 Comment Originated: 01/20/2015
01/20/2015: Please label and show that the pedestrian ramps at the southwest corner of Remington
Street and Lake Street will be directional ramps
Comment #2 Response: Ramp details provided on sheet C1.2.
Comment Number: 3 Comment Originated: 01/20/2015
01/20/2015: Since the retaining wall is in the public right of way, please provide the range in height for
the retaining wall along the sidewalk and the front entry walk. Indicate what the maximum height will
be.
Comment #3 Response: Retaining wall notes added on sheet C1.0, detail on sheet C1.1.
Comment Number: 4 Comment Originated: 01/20/2015
01/20/2015: Since the retaining wall will be in the public right of way, a separate revocable
encroachment permit will be required. Final approval of the encroachment permit will be determined by
the height of the retaining wall. Please see the following link for details:
http://www.fcgov.com/engineering/pdf/encroachmentpermit_digital.pdf
Comment #4 Response: Encroachment submitted for approval with final PDP items.
Department: Environmental Planning
Contact: Stephanie Blochowiak, 970‐416‐2401, sblochowiak@fcgov.com
Topic: General
Page 3 of 9
318 East Oak Street, Fort Collins, CO 80524 + 1531 West 29th Street, Loveland, CO 80538
970.493.1220 + 970.624.6995 + 303.996.3000 + 888.698.7897
Comment Number:1 Comment Originated: 01/20/2015
01/20/2015: With respect to landscaping and design, the City of Fort Collins Land Use Code, in Article
3.2.1 (E)(2)(3), requires that you use native plants and grasses in your landscaping or re landscaping and
reduce bluegrass lawns as much as possible.
Department: Forestry
Contact: Tim Buchanan, 970‐221‐6361, tbuchanan@fcgov.com
Topic: Landscape Plans
Comment Number: 1 Comment Originated: 01/21/2015
01/21/2015: Mark all of the existing trees to retain with that word placed under tree names. This
includes the following trees.
2 Blue Spruce at the SE section of the property
1 American elm at the SE section of the property
1 Green Ash along Remington Street
1 Manchurian Ash along Remington Street
2 Bur Oaks along Lake Street
Comment #1 Response: Trees identified on sheet L101.
Comment Number: 2 Comment Originated: 01/21/2015
01/21/2015: For the landscape area at the SE section of the project under the 2 mature Blue Spruce and
1 American elm mark this landscape area as wood chip mulch with no grading or excavation.
Comment #2 Response: See sheet L101.
Comment Number: 3 Comment Originated: 01/21/2015
01/21/2015: The installation of the six inch fire line and 2 inch water line will destroy the root systems
of the 2 Blue Spruce and One American elm at the SE section of the property with open trench
excavation. The six inch fire line is only a few feet away from these significant trees. Reposition these
water lines at least 20 feet away from the outer bark of these trees to provide adequate root system
protection. Please provide the revised water line design to the City Forester, Project Planner Ryan
Mounce and to the property owner just to to the south of the project for review.
Comment #3 Response: Water lines to be bored, will not interfere with root systems, see sheet C1.0.
Comment Number: 4 Comment Originated: 01/21/2015
01/21/2015: The trees at the SE section of the project which includes the 2 Blue Spruce and 1 American
elm appear to be on or partially on the property to the south. Contact this property owner and review
the proposed plans on how the trees will be retained and protected including the water line placement
location. Provide the property owner all of the project comments submitted by the City Forester on
01/21/2015. Obtain approval or denial from that owner for the treatment of the trees during
development. Provide detailed information so the property owner is aware of any possible impacts to
Page 4 of 9
318 East Oak Street, Fort Collins, CO 80524 + 1531 West 29th Street, Loveland, CO 80538
970.493.1220 + 970.624.6995 + 303.996.3000 + 888.698.7897
his trees. Provide a written response about this contact and if this property owner approves of how his
trees will be protected. Provide the name and contact information for the property owner.
Comment #4 Response: Met with Owner and Forester on site, issue has been resolved, as water lines
will be bored deep enough to not disturb root systems.
Comment Number: 5 Comment Originated: 01/21/2015
01/21/2015: If not already identified on the plan please label the three new street trees along Lake
Street as Bur Oak 2 inch caliper B&B.
Comment #5 Response: Trees labeled/identified per sheet L101.
Comment Number: 6 Comment Originated: 01/21/2015
01/21/2015: Please add these additional landscape notes. Street tree shall be supplied and planted by
the developer using a qualified landscape contractor. The developer shall replace all dead and dying
street trees after planting until final maintenance inspection and acceptance by the City of Fort Collins
Forestry Division. All street trees in the project must be established of an approved species and of
acceptable le condition prior to acceptance.
Comment #6 Response: Notes added to sheet L101.
Comment Number: 7 Comment Originated: 01/21/2015
01/21/2015: Please place this note with larger print with a bold border on the landscape plan. A free
permit must be obtained from the City Forester before any street trees are planted in parkways
between the sidewalk and Curb. Street tree locations and numbers may change to meet actual
utility/tree separation standards. Landscape contractor must obtain approval of street tree location
after utility locates. Street trees must be inspected and approved before planting. Failure to obtain this
permit is a violation of the Code of the City of Fort Collins.
Comment #7 Response: Note provided on sheet L101.
Department: Light And Power
Contact: Luke Unruh, 9704162724, lunruh@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 01/20/2015
01/20/2015: The property is currently being feed from a single phase 100kva transformer. If changes are
anticipated in load capacity, a one line diagram and C1 form will need to be submitted to Light and
Power Engineering. Any modifications to the current electrical system will be at the owners expense.
Please call Luke at 970‐416‐2724.
Comment #1 Response: Items to be submitted upon final determination of required electrical service.
Page 5 of 9
318 East Oak Street, Fort Collins, CO 80524 + 1531 West 29th Street, Loveland, CO 80538
970.493.1220 + 970.624.6995 + 303.996.3000 + 888.698.7897
Department: PFA
Contact: Jim Lynxwiler, 970‐416‐2869, jlynxwiler@poudre‐fire.org
Topic: General
Comment Number: 1 Comment Originated: 01/20/2015
01/20/2015: The following comment is a carryover from prior conceptual review and is being included
here for consistency. The applicant letter associated with the NCU review acknowledges these prior
comments as follows: Remodel and expansion of the fraternity house will not affect existing water
supply and fire access available to the property. As long as the fraternity house remodel will include the
addition of a fire sprinkler system, PFA has only minor comments at this stage. The FDC location needs
to be coordinated with the fire department, a Knox Box is required, and appropriate premise
identification is required. If not already provided, the kitchen will require a hood and duct system under
a separate permit. PFA may have other comments at the time of building plans review.
Comment #1 Response: Knox Box and FDC Locations identified on sheet A001. Other items to be
addressed during building plans review.
Comment Number: 2 Comment Originated: 01/20/2015
01/20/2015: KEY BOXES REQUIRED
Poudre Fire Authority requires key box ("Knox Box") to be mounted in an approved, exterior location on
every new or existing building equipped with a required fire sprinkler or fire alarm system. The box shall
be positioned 3 to 7 feet above finished floor and within 10 feet of the front door, or closest door to the
fire alarm panel. Exception can be made by the PFA if it is more logical to have the box located
somewhere else on the structure. All new or existing Knox Boxes must contain the following keys as
they apply to the building:
> Exterior Master.
> Riser room.
> Fire panel.
> Elevator key if equipped with an elevator.
The number of floors determines the number of sets of keys needed. Each set will be placed on their
own key ring.
> Single story buildings must have 1 of each key.
> 2‐3 story buildings must have 2 of each key.
> 4+ story buildings must have 3 of each key.
For further details or to determine the size of Knox Box required, contact the Poudre Fire Authority
Division of Community Safety Services.
Comment #2 Response: Knox Box location has been provided on sheet A001 and North Elevation sheet
A301. Required key sets will be provided.
Department: Stormwater Engineering
Contact: Basil Hamdan, 970‐224‐6035, bhamdan@fcgov.com
Topic: General
Page 6 of 9
318 East Oak Street, Fort Collins, CO 80524 + 1531 West 29th Street, Loveland, CO 80538
970.493.1220 + 970.624.6995 + 303.996.3000 + 888.698.7897
Comment Number: 2 Comment Originated: 01/20/2015
01/20/2015: Please provide a letter drainage report addressing how much impervious area is being
added with this project. Show basin delineations on the plans.
Comment #2 Response: New proposed impervious area total is well below 1000 sq.ft. Civil has met
with Basil to resolve comment.
Comment Number: 3 Comment Originated: 01/20/2015
01/20/2015: Please provide a water quality treatment for the site, a bioretention pond should be
considered before flows are released even if the site did not historically provide any WQ treatment.
Comment #3 Response: Not applicable as determined by meeting with City Engineers and Civil.
Comment Number: 4 Comment Originated: 01/20/2015
01/20/2015: Please add grading elevations especially in the area for the addition, show how the flows
exit the site and enter the alley. Provide a detail for the retaining wall along Lake Street.
Comment #4 Response: Grading provided on sheet C1.0. Refer to Civil Sheets regarding retaining wall.
Contact: Jesse Schlam, 970‐218‐2932, jschlam@fcgov.com
Topic: Erosion Control
Comment Number: 1 Comment Originated: 01/13/2015
01/13/2015: No Comment from Erosion Control. This site; disturbs less than 10,000 sq‐ft, is not in a
sensitive area, and is not in a larger development under construction. Therefore, no submittal of erosion
control material is needed. However, the site still must be swept and maintained to prevent dirt, saw
cuttings, concrete wash, and other pollutants from entering the storm sewer at all times or BMPs will be
required of the site. If you need clarification concerning this, or if there are any questions please contact
Jesse Schlam 970‐218‐2932 or email to jschlam@fcgov.com
Comment #1 Response: Documentation for runoff control to be provided during building plans review.
Department: Technical Services
Contact: Jeff County, 970‐221‐6588, jcounty@fcgov.com
Topic: Building Elevations
Comment Number: 1 Comment Originated: 01/20/2015
01/20/2015: There are line over text issues. See redlines.
Comment #1 Response: Instances have been addressed.
Topic: Construction Drawings
Comment Number: 2 Comment Originated: 01/20/2015
01/20/2015: Please change the title of sheet C1.0 to "Site & Utility Plan".
Page 7 of 9
318 East Oak Street, Fort Collins, CO 80524 + 1531 West 29th Street, Loveland, CO 80538
970.493.1220 + 970.624.6995 + 303.996.3000 + 888.698.7897
Comment #2 Response: Title of C1.0 has been changed to “Site & Grading Plan”.
Comment Number: 3 Comment Originated: 01/20/2015
01/20/2015: There are line over text issues. See redlines.
Comment #3 Response: Instances have been addressed.
Comment Number: 4 Comment Originated: 01/20/2015
01/20/2015: The City has moved to the NAVD88 vertical datum. Please provide the following
information in the EXACT format shown below.
If your project is started on NAVD88 datum:
1) PROJECT DATUM: NAVD88
BENCHMARK #1 w/ DESCRIPTION
ELEVATION:
BENCHMARK #2 w/ DESCRIPTION
ELEVATION:
OR, if project has already been surveyed in NAVD29 Unadjusted datum:
2) PROJECT DATUM: NGVD29 UNADJUSTED (OLD CITY OF FORT COLLINS DATUM)
BENCHMARK #1 w/ DESCRIPTION
ELEVATION:
BENCHMARK #2 w/ DESCRIPTION
ELEVATION:
If using NGVD29 UNADJUSTED the following equation statement will be needed.
NOTE: IF NAVD 88 DATUM IS REQUIRED FOR ANY PURPOSE, THE
FOLLOWING EQUATION SHOULD BE USED: NAVD88 = NGVD29 UNADJUSTED
+ X.XX’
Comment #4 Response: See Civil sheets for compliance.
Topic: Landscape Plans
Comment Number: 5 Comment Originated: 01/20/2015
01/20/2015: There are line over text issues. See redlines.
Comment #5 Response: Instances have been addressed.
Page 8 of 9
318 East Oak Street, Fort Collins, CO 80524 + 1531 West 29th Street, Loveland, CO 80538
970.493.1220 + 970.624.6995 + 303.996.3000 + 888.698.7897
Topic: Site Plan
Comment Number: 6 Comment Originated: 01/20/2015
01/20/2015: Please add a legal description of the project property.
Comment #6 Response: Legal description has been provided on sheet A001.
Comment Number: 7 Comment Originated: 01/20/2015
01/20/2015: Please change the title of sheet A001, and add the Landscape plan to
the index on sheet T.1.
Comment #7 Response: Completed.
Comment Number: 8 Comment Originated: 01/20/2015
01/20/2015: There are line over text issues. See redlines.
Comment #8 Response: Instances have been addressed.
Comment Number: 9 Comment Originated: 01/20/2015
01/20/2015: There is text that needs to be masked. Mask all text in hatched areas.
See redlines.
Comment #9 Response: Instances have been addressed.
Department: Traffic Operation
Contact: Martina Wilkinson, 970‐221‐6887, mwilkinson@fcgov.com
Topic: General
Comment Number: 2 Comment Originated: 01/21/2015
01/21/2015: no other comments from traffic or transportation planning,
Comment #2 Response: No response requested/implied.
Topic: Site Plan
Comment Number: 1 Comment Originated: 01/21/2015
01/21/2015: Looks like we'll need to adjust the sidewalk ramps at Remington to make them directional.
Comment #1 Response: See details on sheet C1.2.
Department: Water‐Wastewater Engineering
Contact: Basil Hamdan, 970‐224‐6035, bhamdan@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 01/20/2015
Page 9 of 9
318 East Oak Street, Fort Collins, CO 80524 + 1531 West 29th Street, Loveland, CO 80538
970.493.1220 + 970.624.6995 + 303.996.3000 + 888.698.7897
01/20/2015: Water Line: Please call out locations of existing service. will the new service be at the same
location as existing? If not please add a note stating that the existing service/fire lines will be abandoned
at the main. A meter pit should be located on private property beyond the ROW line and a curb stop
should be located behind the sidewalk. A reducer from the 2" line to the 1 and half line should be called
out at least 5 feet from meter pit. Provide details for all proposed appurtenances, including meter pit
and water line connection. Add a note stating that the installation of the 1 and a half line will be
coordinated by the contractor with City of Fort Collins Utilities (call 221 6700)
Comment #1 Response: See revised Civil sheets.
Comment Number: 2 Comment Originated: 01/20/2015
01/20/2015: Fire line: Please add thrust blocks for fire line at the connection point to the 12 inch water
line and at all bends. Call out bends in fire line, provide details for thrust blocks.
Comment #3 Response: See revised Civil sheets.
Comment Number: 3 Comment Originated: 01/20/2015
01/20/2015: Sewer line: Please call out a Clean Out for the Sewer line between the
building and the alley.
Comment #3 Response: Clean Out is not required as no modification is occurring to existing line.
Department: Zoning
Contact: Noah Beals, 970‐416‐2313, nbeals@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 01/20/2015
01/20/2015: The new trash enclosure will need to have a walk‐in access separate from the main service
gate.
Comment #1 Response: Comment was addressed; however, the specific site contraints, and operational
layout requirements would not effectively utilize an additional access location. Therefore, it is
requested that the additional walk‐in access not be required due to impracticality regarding the nature
of the existing site configuration. The addition of the Trash Enclosure is an improvement upon the
existing condition.
Comment Number: 2 Comment Originated: 01/20/2015
01/20/2015: The signature block for planning should be updated to read Director of
Community Development and Neighborhood services.
Comment #2 Response: Corrected on sheet A001.
( END OF PLANNING RESPONSE DOCUMENT )